Sei sulla pagina 1di 1

Carga equilibrada en Y - Y con

neutro. foco
Vfoco ≔ 14 V
V ≔ 220 V f ≔ 50 Hz
Voltajes de línea a línea. Pfoco ≔ 21 W
⎛⎝Vfoco⎞⎠ 2
V'BN ≔ V ∠ -30° = ((220 ∠ -30°)) V Rfoco ≔ ―――= ((9.333 ∠ 0°)) Ω
Pfoco
V'AN ≔ V ∠ 90° = ((220 ∠ 90°)) V
Z ≔ ((100 ∠ 2.865°)) Ω
V'CN ≔ V ∠ -150° = ((220 ∠ -150°)) V Rfoco ⋅ Z
Ztotal ≔ ―――= ((8.537 ∠ 0.244°)) Ω
Transformación de voltajes. Rfoco + Z

132.414
VBN ≔ V'BN ⋅ ―――= ((14.4 ∠ -30°)) V
2023

132.414
VAN ≔ V'AN ⋅ ―――= ((14.4 ∠ 90°)) V
2023

132.414
VCN ≔ V'CN ⋅ ―――= ((14.4 ∠ -150°)) V
2023

Voltajes de fase.
‾‾
3 ⋅ VAN
VAB ≔ ―――= ((24.941 ∠ 60°)) V
1 ∠ 30°

‾‾
3 ⋅ VBN
VBC ≔ ―――= ((24.941 ∠ -60°)) V
1 ∠ 30°

‾‾
3 ⋅ VCN
VCA ≔ ―――= ((24.941 ∠ -180°)) V
1 ∠ 30°

Corrientes de línea
VAN PT ≔ 3 ⋅ 14.4 V ⋅ 1.687 A ⋅ cos ((90° - 89.756°)) = 72.878 W
IA ≔ ――= ((1.687 ∠ 89.756°)) A
Ztotal ST ≔ 3 ⋅ 14.4 V ⋅ 1.687 A = 72.878 W
VBN
IB ≔ ――= ((1.687 ∠ -30.244°)) A QT ≔ ‾‾‾‾‾‾‾‾
ST 2 - PT 2 = 0.31 V ⋅ A R
Ztotal
PT
VCN cos ((ϕ)) ≔ ―― =1
IC ≔ ――= ((1.687 ∠ -150.244°)) A ST
Ztotal PTgenerador ≔ ‾‾
3 ⋅ 24.941 V ⋅ 1.687 A ⋅ cos ((0.244°)) = 72.876 W

Corriente por el neutro STgenerador ≔ ‾‾


3 ⋅ 24.941 V ⋅ 1.687 A = 72.877 W

IN ≔ IA + IB + IC = 0 A QTgenerador ≔ ‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾
STgenerador 2 - PTgenerador 2 = 0.31 V ⋅ A R

Potrebbero piacerti anche