Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
DATA ORIGINALE: 05/05/2004 ULTIMA REV. 30/06/2004 GUIDA REV 01 NR. FG 1/1
A001_00
Progettista :
Commessa:
Progettista :
Commessa:
DIN41612-CA_C64M9S
Q2 A3 Y3 A2 B2
DIN41612-CA_C64M9S
7 STAD11 STAD23 5 15 *STAD23 15C 15A 15C 15A D2 4 16 ED2
Q3 A4 Y4 A3 B3
A0 1 9 STAD12 STAD25 6 14 *STAD25 ED0 16C 16A 16C 16A D3 5 15 ED3
S0 Q4 A5 Y5 A4 B4
A1 2 10 STAD13 STAD27 7 13 *STAD27 ED1 17C 17A 17C 17A D4 6 14 ED4
S1 Q5 A6 Y6 A5 B5
A2 3 11 STAD14 STAD29 8 12 *STAD29 VCC ED2 18C 18A 18C 18A D5 7 13 ED5
S2 Q6 A7 Y7 A6 B6
VCC 12 STAD15 STAD31 9 11 *STAD31 ED3 19C 19A 19C 19A D6 8 12 ED6 VCC
Q7 A8 Y8 VCC A7 B7
C11 CLR 20 ED4 20C 20A 20C 20A D7 9 11 ED7
1 VCC A8 B8
15 74HC259 C23 OE1 C2 ED5 21C 21A 21C 21A 20
100n G05 N.M. 19 10 100n 1 R/*W 1 DIR VCC
63V VCC;16 OE2 GND 22C 22A
G05;8 63V ED6 22C 22A C6
*RES 10n 23C 23A *SEL 19 OE 10 100n
63V G05 G05 ED7 23C 23A GND 63V
74HC540 SL08
G05 2% 24C 24A
U96 24C 24A 74HC245
4K7
RN11 25C 25A G05
D0 13 4 STAD16 U3 *EVPA 25C 25A *RDBUF
D Q0
*CS2 14 5 STAD17 STAD33 2 18 *STAD33 26C 26A 2 26C 26A
G Q1 A1 Y1 *CS0GAL
6 STAD18 STAD35 3 17 *STAD35 ER/*W 27C 27A 3 27C 27A
Q2 A2 Y2 *CS1
7 STAD19 STAD37 4 16 *STAD37 28C 28A 4 28C 28A U101
Q3 A3 Y3 *CS2
STAD39 5 15 *STAD39 29C 29A *EVPA 2 18 *VPA
A0 1 9 STAD20 A4 Y4 *ERES 29C 29A 5 A1 Y1
S0 Q4 *CS3 EVMA 3 17 VMA
A1 2 10 STAD21 *VPA 6 14 DVPA 30C 30A 6 30C 30A A2 Y2
S1 Q5 A5 Y5 *CS4
DVPA 7 13 *DVPA 31C 31A EA11 4 16 A11
A2 3 11 STAD22 A6 Y6 31C 31A 7 A3 Y3
S2 Q6 *SEL EA10 5 15 A10
*ERES R52 10K *INTERES 8 12 RES VCC 32C 32A A4 Y4
VCC 12 STAD23 A7 Y7 32C 32A 8
Q7 EA9 6 14 A9
C10 CLR RES 9 11 *RES A5 Y5
C25 A8 Y8
10n 20 EA8 7 13 A8
15 74HC259 C22 VCC A6 Y6
100n G05 N.M. 63V 1 OE1 EA7 8 12 A7
63V VCC;16 C3 A7 Y7 VCC
G05;8 19 10 100n
*RES 10n G05 OE2 GND 63V G05 EA6 9 11 A6
63V G05 A8 Y8
G05
U97 G05 74HC540 1
G05 OE1 VCC 20
D0 13 4 STAD24 VP 19
D Q0 DS2 OE2 GND 10 C5
100n
*CS3 14 5 STAD25 U94 63V
G Q1 R21 18K 74HC541
6 STAD26 Q 1 23 *RDBUF G05
Q2 CLK/I0 I/O9
7 STAD27 R/*W 2 22 *CS0GAL 1 W8 2 *CS0 VERDE 3MM G05
Q3 I1 I/O8
A0 1 9 STAD28 A3 3 21 *CS1
S0 Q4 I2 I/O7 J3 D1
A1 2 10 STAD29 A11 A4 4 20 *CS2 1 1N5402 U102
S1 Q5 I3 I/O6 *ALL1 2 18 D0
A5 5 19 *CS3 2 A1 Y1
A2 3 11 STAD30 1 I4 I/O5 *ALL2 3 17 D1
S2 Q6 A2 Y2
MODU1_8_MN
12 STAD31 A6 6 18 *CS4 3
VCC Q7 I5 I/O4 *ALL3 4 16 D2
CLR 2 A7 7 17 *SEL 4 A3 Y3
C9 W6 I6 I/O3 VN G048 VCC *ALL4 5 15 D3
A8 8 16 S2 5 A4 Y4
15 74HC259 C21 I7 I/O2 *ALL5 6 14 D4
100n VCC;16 3 A5 Y5
63V G05 N.M. A9 9 15 S1 VCC 6
G05;8 S3 I8 I/O1 7 13 D5
10n A10 10 14 VMA 7 A6 Y6
*RES 63V G05 I9 I/O0 8 12 D6
*DVPA IGAL10 11 24 8 A7 Y7 VCC
I10 VCC 9 11 D7
1N5402 A8 Y8
IGAL11 13 12 C13 D2
1 I11 GND 100n
U98 63V DS1 1 OE1 VCC 20
22V10-10
2 R22 18K *RDBUF 19
D0 13 4 STAD32 W7
G05 OE2 GND 10 C4
100n
D Q0
*CS4 14 5 STAD33 GIALLO 3MM 63V
G Q1 G048 74HC541
3 VCC
6 STAD34 S4 G05
Q2
7 STAD35
Q3
A0 1 9 STAD36 S1
S0 Q4 S1 1 8
A1 2 10 STAD37 S2 2 7 MASS
S1 Q5
A2 3 11 STAD38 S3 3 6
S2 Q6 VCC
VCC 12 STAD39 S4 4 5 SCHEDA: 950A/1 CODICE: 41544001 FILE: 950A_01.1
Q7
C8 CLR Q1 1 2
VCC
U92 U93
STAD24 2 18 BSTAD24 STAD32 2 18 BSTAD32
A1 Y1 A1 Y1
STAD25 3 17 BSTAD25 STAD33 3 17 BSTAD33
A2 Y2 A2 Y2
STAD26 4 16 BSTAD26 STAD34 4 16 BSTAD34 R51
A3 Y3 A3 Y3 220
STAD27 5 15 BSTAD27 STAD35 5 15 BSTAD35
A4 Y4 A4 Y4
STAD28 6 14 BSTAD28 STAD36 6 14 BSTAD36
A5 Y5 A5 Y5
STAD29 7 13 BSTAD29 STAD37 7 13 BSTAD37 KOCN J9
A6 Y6 A6 Y6 1
MODU2_4_MN
STAD30 8 12 BSTAD30 STAD38 8 12 BSTAD38 1 4
A7 Y7 A7 Y7
STAD31 9 11 BSTAD31 VCC U109 2
A8 Y8 STAD39 9 11 BSTAD39 VCC TLP621
A8 Y8 3
1 OE1 VCC 20 1 2 3
OE1 VCC 20 4
RES 19 OE2 GND 10 C17 RES 19
100n OE2 GND 10 C18
100n
G05
63V 63V
74AC541 74AC541
G05 G05
HYB07A-5V
HYB07A-5V
HYB07A-5V
IN5 IN5 IN5 IN5
5 STAD4 5 STAD12 5 STAD20 5 STAD28 5 STAD36
IN4 IN4 IN4 IN4 IN4
4 *STAD5 4 *STAD13 4 *STAD21 4 *STAD29 4 *STAD37
IN3 IN3 IN3 IN3 IN3
3 STAD6 3 STAD14 3 STAD22 3 STAD30 3 STAD38
IN2 IN2 IN2 IN2 IN2
2 *STAD7 2 *STAD15 2 *STAD23 2 *STAD31 2 *STAD39
IN1 IN1 IN1 IN1 IN1
1 1 1 1 1
COM COM COM COM COM
1N4004
D4
1 4 1 4 1 4 1 4
1N4004
U4 U6 U8 U11 D5
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3 R1
100
3 5 7 9 1N4004
D6
SL10 SL10 SL10 SL10
2% RT1 2% RT3 2% RT5 2% RT8
270 850 270 850 270 850 270 850
RN1 RN1 RN1 RN1
R23 330 Q2
1 1 1 1 MPSA92
MASS MASS MASS MASS
BSTAD0 OUT0 BSTAD1 OUT1 BSTAD2 OUT2 BSTAD3 OUT3
RIF RIF RIF RIF
1 1 1 1
2 4 6 8
VCC
1 4 1 4 1 4 1 4 6 4
U5 U7 U9 U10 U84
TLP627 TLP627 TLP627 TLP627 PC829
2 3 2 3 2 3 2 3 5 3
*ALL1
1 4 1 4 1 4 1 4
U15 U12 U19 U16
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3
8 6 4 2
1 4 1 4 1 4 1 4
U14 U13 U18 U17
TLP627 TLP627 TLP627 TLP627
R24 330 Q8
2 3 2 3 2 3 2 3 MPSA42
RIFVN1 RIFVN1 RIFVN1 RIFVN1
1N4004 R2
D8 100
RIF MASS
VCC 1N4004
J8 D7
OUT0 1 2 1 1
1 4 1 4 1 4 1 4
1N4004
U23 U20 U27 U24 D9
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3 R4
100
3 5 7 9 1N4004
D10
SL10 SL10 SL10 SL10
2% RT20 2% RT17 2% RT24 2% RT21
270 850 270 850 270 850 270 850
RN4 RN4 RN4 RN4
R26 330 Q3
1 1 1 1 MPSA92
MASS MASS MASS MASS
BSTAD8 OUT8 BSTAD9 OUT9 BSTAD10 OUT10 BSTAD11 OUT11
RIF RIF RIF RIF
1 1 1 1
2 4 6 8
VCC
1 4 1 4 1 4 1 4 6 4
2 3 2 3 2 3 2 3 5 3
*ALL2
1 4 1 4 1 4 1 4
U32 U35 U28 U31
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3
8 6 4 2
1 4 1 4 1 4 1 4
U33 U34 U29 U30
TLP627 TLP627 TLP627 TLP627
R25 330 Q9
2 3 2 3 2 3 2 3 MPSA42
RIFVN2 RIFVN2 RIFVN2 RIFVN2
1N4004 R3
D11 100
VCC
J7 1N4004
OUT8 1 2 RIF MASS D12
OUT9 3 4 1 1
OUT10 5 6 G048 R47
MODU2_8X2_MN
1 4 1 4 1 4 1 4
1N4004
U39 U36 U43 U40 D13
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3 R6
100
3 5 7 9 1N4004
D14
SL10 SL10 SL10 SL10
2% RT36 2% RT33 2% RT40 2% RT37
270 850 270 850 270 850 270 850
RN6 RN6 RN6 RN6
R28 330 Q4
1 1 1 1 MPSA92
MASS MASS MASS MASS
BSTAD16 OUT16 BSTAD17 OUT17 BSTAD18 OUT18 BSTAD19 OUT19
RIF RIF RIF RIF
1 1 1 1
2 4 6 8
VCC
1 4 1 4 1 4 1 4 6 4
2 3 2 3 2 3 2 3 5 3
*ALL3
1 4 1 4 1 4 1 4
U48 U51 U44 U47
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3
8 6 4 2
1 4 1 4 1 4 1 4
U49 U50 U45 U46
TLP627 TLP627 TLP627 TLP627
R27 330 Q10
2 3 2 3 2 3 2 3 MPSA42
RIFVN3 RIFVN3 RIFVN3 RIFVN3
1N4004 R5
D15 100
VCC
J6 1N4004
OUT16 1 2 D16
OUT17 3 4 RIF MASS
OUT19 7 8 4K7
1/8W KOCN RN5 RN6
OUT20 9 10 5% 270 270 VN
2% 2%
OUT21 11 12 SL10 SL10
R46 4K7 Q15
OUT22 13 14 BC337
1/8W 5% 10 10
OUT23 15 16 2 SCHEDA: 950A/1 CODICE: 41544001 FILE: 950A_01.5
1 3
W3
G048 G05 G05 DESCRIZIONE: USCITE 17-24 PER CERAMICHE CON PROTEZIONE AL C.C.
1 4 1 4 1 4 1 4
1N4004
U55 U52 U59 U56 D17
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3 R8
100
3 5 7 9 1N4004
D18
SL10 SL10 SL10 SL10
2% RT52 2% RT49 2% RT56 2% RT53
270 850 270 850 270 850 270 850
RN8 RN8 RN8 RN8
R30 330 Q5
1 1 1 1 MPSA92
MASS MASS MASS MASS
BSTAD24 OUT24 BSTAD25 OUT25 BSTAD26 OUT26 BSTAD27 OUT27
RIF RIF RIF RIF
1 1 1 1
2 4 6 8
VCC
1 4 1 4 1 4 1 4 6 4
2 3 2 3 2 3 2 3 5 3
*ALL4
1 4 1 4 1 4 1 4
U64 U67 U60 U63
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3
8 6 4 2
1 4 1 4 1 4 1 4
U65 U66 U61 U62
TLP627 TLP627 TLP627 TLP627
R29 330 Q11
2 3 2 3 2 3 2 3 MPSA42
RIFVN4 RIFVN4 RIFVN4 RIFVN4
1N4004 R7
D19 100
VCC
J5 1N4004
OUT24 1 2 D20
OUT27 7 8 4K7
1/8W KOCN RN7 RN8
OUT28 9 10 5% 270 270 VN
2% 2%
OUT29 11 12 SL10 SL10
R44 4K7 Q14
OUT30 13 14 BC337
1/8W 5% 10 10
OUT31 15 16 2
SCHEDA: 950A/1 CODICE: 41544001 FILE: 950A_01.6
1 3
W2
G048 G05 G05
DESCRIZIONE: USCITE 25-32 PER CERAMICHE CON PROTEZIONE AL C.C.
1 4 1 4 1 4 1 4
1N4004
U71 U68 U75 U72 D21
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3 R10
100
3 5 7 9 1N4004
D22
SL10 SL10 SL10 SL10
2% RT68 2% RT65 2% RT72 2% RT69
270 850 270 850 270 850 270 850
RN10 RN10 RN10 RN10
R32 330 Q6
1 1 1 1 MPSA92
MASS MASS MASS MASS
BSTAD32 OUT32 BSTAD33 OUT33 BSTAD34 OUT34 BSTAD35 OUT35
RIF RIF RIF RIF
1 1 1 1
2 4 6 8
VCC
1 4 1 4 1 4 1 4 6 4
2 3 2 3 2 3 2 3 5 3
*ALL5
1 4 1 4 1 4 1 4
U80 U83 U76 U79
TLP627 TLP627 TLP627 TLP627
2 3 2 3 2 3 2 3
8 6 4 2
1 4 1 4 1 4 1 4
U81 U82 U77 U78
TLP627 TLP627 TLP627 TLP627
R31 330 Q12
2 3 2 3 2 3 2 3 MPSA42
RIFVN5 RIFVN5 RIFVN5 RIFVN5
1N4004 R9
D23 100
VCC
J4 RIF MASS 1N4004
OUT32 1 2 D24
OUT33 3 4 1 1
OUT34 5 6 G048 R41
MODU2_8X2_MN
S.p.A.
REDATTO : Roberto Conti
PARTICOLARE IN VETRONITE PV020
NOTA: I n.ro 6 particolari in vetronite PV020 devono essere inseriti
tra le file di ptc (2 particolari ogni fila) come indicato in figura. SCHEDA : 950A/1 CODICE : 41544001 FILE : T002_00.SKF
I particolari in vetronite devono essere fissati al circuito stampato DESCRIZIONE : VISTA COMPONENTI
unicamente con il seguente materiale:
NOTE : Fissaggio particolari in vetronite.
* Silicone Universale BOSTIK SILICON5 R
FOGLIO : T002_00 DATA : 30/06/2004
S.p.A.
REDATTO : Roberto Conti
Pagina 1/8
Dinema S.p.A.
LISTA COMPONENTI Via San Polo, 183
Brescia - Italy
Descrizione: Scheda 950A/1 Codice: 41544001 Data: 05/05/2004
Cliente: Dinema S.p.A. Documento: L001_00 Redatto: Conti Roberto
LISTA PARTI
CODICE DESCRIZIONE QUANTITA' REFDES NOTE
U105
U106
U107
U108
R42
R43
R44
R45
R46
R47
R48
R49
R50
R10
R2
R3
R4
R5
R6
R7
R8
R9
R24
R25
R26
R27
R28
R29
R30
R31
R32
R35
R36
R37
R38
Pagina 2/8
Dinema S.p.A.
LISTA COMPONENTI Via San Polo, 183
Brescia - Italy
Descrizione: Scheda 950A/1 Codice: 41544001 Data: 05/05/2004
Cliente: Dinema S.p.A. Documento: L001_00 Redatto: Conti Roberto
R40
R53
R54
R12
R13
R14
R15
R16
R17
R18
R19
R20
R22
RT10
RT11
RT12
RT13
RT14
RT15
RT16
RT17
RT18
RT19
RT2
RT20
RT21
RT22
RT23
RT24
RT25
RT26
RT27
RT28
RT29
RT3
RT30
RT31
RT32
RT33
RT34
RT35
RT36
RT37
RT38
RT39
Pagina 3/8
Dinema S.p.A.
LISTA COMPONENTI Via San Polo, 183
Brescia - Italy
Descrizione: Scheda 950A/1 Codice: 41544001 Data: 05/05/2004
Cliente: Dinema S.p.A. Documento: L001_00 Redatto: Conti Roberto
RT40
RT41
RT42
RT43
RT44
RT45
RT46
RT47
RT48
RT49
RT5
RT50
RT51
RT52
RT53
RT54
RT55
RT56
RT57
RT58
RT59
RT6
RT60
RT61
RT62
RT63
RT64
RT65
RT66
RT67
RT68
RT69
RT7
RT70
RT71
RT72
RT73
RT74
RT75
RT76
RT77
RT78
RT79
RT8
RT80
RT9
D11
D12
D13
D14
D15
Pagina 4/8
Dinema S.p.A.
LISTA COMPONENTI Via San Polo, 183
Brescia - Italy
Descrizione: Scheda 950A/1 Codice: 41544001 Data: 05/05/2004
Cliente: Dinema S.p.A. Documento: L001_00 Redatto: Conti Roberto
D17
D18
D19
D20
D21
D22
D23
D24
D3
D4
D5
D6
D7
D8
D9
D2
Q14
Q15
Q16
Q17
Q11
Q12
Q8
Q9
Q3
Q4
Q5
Q6
RN10
RN2
RN3
RN4
RN5
Pagina 5/8
Dinema S.p.A.
LISTA COMPONENTI Via San Polo, 183
Brescia - Italy
Descrizione: Scheda 950A/1 Codice: 41544001 Data: 05/05/2004
Cliente: Dinema S.p.A. Documento: L001_00 Redatto: Conti Roberto
RN7
RN8
RN9
J5
J6
J7
J8
J2
W2 # JUMPER 3P MASCHIO
W3 # JUMPER 3P MASCHIO
W4 # JUMPER 3P MASCHIO
W5 # JUMPER 3P MASCHIO
W6 # JUMPER 3P MASCHIO
W7 # JUMPER 3P MASCHIO
W8 # JUMPER 2P MASCHIO
C10
C11
C12
C13
C14
C15
C16
C17
C18
C2
C3
C4
C5
C6
C7
C8
C9
Dinema S.p.A.
LISTA COMPONENTI Via San Polo, 183
Brescia - Italy
Descrizione: Scheda 950A/1 Codice: 41544001 Data: 05/05/2004
Cliente: Dinema S.p.A. Documento: L001_00 Redatto: Conti Roberto
U11
U12
U13
U14
U15
U16
U17
U18
U19
U20
U21
U22
U23
U24
U25
U26
U27
U28
U29
U30
U31
U32
U33
U34
U35
U36
U37
U38
U39
U4
U40
U41
U42
U43
U44
U45
U46
U47
U48
U49
U5
U50
U51
U52
U53
U54
U55
U56
U57
U58
U59
U6
U60
Pagina 7/8
Dinema S.p.A.
LISTA COMPONENTI Via San Polo, 183
Brescia - Italy
Descrizione: Scheda 950A/1 Codice: 41544001 Data: 05/05/2004
Cliente: Dinema S.p.A. Documento: L001_00 Redatto: Conti Roberto
U62
U63
U64
U65
U66
U67
U68
U69
U7
U70
U71
U72
U73
U74
U75
U76
U77
U78
U79
U8
U80
U81
U82
U83
U9
U85
U86
U87
U88
U96
U97
U98
U99
U2
U3
U101
U102
U90
U91
Pagina 8/8
Dinema S.p.A.
LISTA COMPONENTI Via San Polo, 183
Brescia - Italy
Descrizione: Scheda 950A/1 Codice: 41544001 Data: 05/05/2004
Cliente: Dinema S.p.A. Documento: L001_00 Redatto: Conti Roberto
U93
Tabella per corretta configurazione Jumper W6, W7 e W8 in base alla Logica Programmabile utilizzata sulla
scheda:
Logica
Programmabile Pos. W6 Pos. W7 Pos. W8 Note
utilizzata
G950A01 1–2 1–2 CHIUSO Possibilità di comando n.ro 40 uscite
G950A02 1–2 1–2 CHIUSO Possibilità di comando n.ro 32 uscite
G950A03 1–2 1–2 CHIUSO Possibilità di comando n.ro 32 uscite
G950A04 1–2 1–2 CHIUSO Possibilità di comando n.ro 40 uscite
G950A05 2–3 1–2 CHIUSO Possibilità di comando n.ro 32 uscite
G950A06 2–3 1–2 CHIUSO Possibilità di comando n.ro 32 uscite
G950A07 2–3 2–3 APERTO Possibilità di comando n.ro 32 uscite
G950A08 2–3 1–2 CHIUSO Possibilità di comando n.ro 40 uscite
Tabella per corretta configurazione jumper per abilitazione Allarme Mancanza Connettore:
JUMPER POSIZIONE FUNZIONE
1-2 Allarme mancanza cablaggio sul connettore J4 ABILITATA.
W1
2-3 Allarme mancanza cablaggio sul connettore J4 DISABILITATA.
1-2 Allarme mancanza cablaggio sul connettore J5 ABILITATA.
W2
2-3 Allarme mancanza cablaggio sul connettore J5 DISABILITATA.
1-2 Allarme mancanza cablaggio sul connettore J6 ABILITATA.
W3
2-3 Allarme mancanza cablaggio sul connettore J6 DISABILITATA.
1-2 Allarme mancanza cablaggio sul connettore J7 ABILITATA.
W4
2-3 Allarme mancanza cablaggio sul connettore J7 DISABILITATA.
1-2 Allarme mancanza cablaggio sul connettore J8 ABILITATA.
W5
2-3 Allarme mancanza cablaggio sul connettore J8 DISABILITATA.
a001_00.doc 1/1