Calcolo Precarico e Coppia di Serraggio Viti

Viti TCEI UNI 5931 ISO 4762 DIN 912; TE UNI 5737, ISO 4014, DIN 931

d ≔ 6 mm Diametro Nominale Vite p ≔ 1 mm Passo Vite

H ≔ 0.86603 p = 0.866 mm H1 ≔ 0.54127 p = 0.541 mm

h3 ≔ 0.61343 p = 0.613 mm R ≔ 0.14434 p = 0.144 mm

d2 ≔ d - 0.64953 p = 5.35 mm d1 ≔ d - 2 ⋅ H1 = 4.917 mm


π
d3 ≔ d - 1.22687 ⋅ p = 4.773 mm Ak ≔ ―⋅ ⎛⎝d3⎞⎠ 2 = 17.894 mm 2
4
⎛ d2 + d 3 ⎞ π
ds ≔ ⎜――― ⎟ = 5.062 mm As ≔ ―⋅ ds 2 = 20.123 mm 2
⎝ 2 ⎠ 4

Determinazione Carico Massimo e Precarico

Classe Vite: 8.8 σR ≔ 800 MPa σ0.2 ≔ 640 MPa

⎛ p ⎞
α ≔ atan ⎜―― ⎟ = 3.405 ° ρ ≔ 0.1 μ ≔ atan ((ρ)) = 5.711 °
⎝ π ⋅ d 2⎠

μ' ≔ tan ((α + μ)) = 0.16 k ≔ 0.9999 k ⋅ σ0.2 = 640 MPa

kp ≔ 0.8 Coefficiente di Precarico de ≔ 10 mm Diametro esterno Testa Vite

σ0.2 ⋅ As kp ⋅ k ⋅ σ0.2 ⋅ As
Fvmax ≔ ―――――――― = 11104 N Fprec ≔ ―――――――― = 8883 N
‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾ 2 ‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾ 2
⎛ μ' ⋅ As ⋅ ⎛⎝d2⎞⎠ ⎞ ⎛ μ' ⋅ As ⋅ ⎛⎝d2⎞⎠ ⎞
1 + 3 ⋅ ⎜―――― ⎟ 1 + 3 ⋅ ⎜―――― ⎟
⎜ ⎛⎝ds⎞⎠ 3 ⎟ ⎜ ⎛⎝ds⎞⎠ 3 ⎟
⎜⎝ 2 ⋅ π ⋅ ――16 ⎟⎠ ⎜⎝ 2 ⋅ π ⋅ ―― 16 ⎟⎠

Determinazione Coppia di Serraggio Massima e di Precarica

⎛ de + d ⎞
dm ≔ ⎜――⎟ = 8 mm Diametro Medio μa ≔ 0.1 Coefficente d'attrito Sotto
⎝ 2 ⎠ Testa Vite Testa Vite con Flangia

⎛ d2 dm ⎞
Msmax ≔ Fvmax ⎜―⋅ tan ((α + ρ)) + ― ⋅ μa⎟ = 9.2 N·m Coppia di Serraggio Massima
⎝2 2 ⎠

⎛ d2 dm ⎞
Msp ≔ Fprec ( )
⎜―⋅ tan (α + ρ) + ― ⋅ μa⎟ = 7.4 N·m Coppia di Serraggio Precarica
⎝2 2 ⎠
Calcolo Precarico e Coppia di Serraggio Viti

Determinazione Interferenza di Precarico

L ≔ 30 mm Fprec = 8883 N
π
Ad ≔ ―⋅ d 2 = 28.274 mm 2
4

Fprec Fprec
σd ≔ ―― = 314.2 MPa σds ≔ ―― = 441.4 MPa σ0.8 ≔ kp ⋅ σ0.2 = 512 MPa
Ad As

σd
E ≔ 205000 MPa εd ≔ ―= 0.001532 ΔLd ≔ εd ⋅ L = 0.046 mm
E

2 σds
As = 20.123 mm εds ≔ ―― = 0.002153
E

ΔLds ≔ εds ⋅ L = 0.065 mm

Potrebbero piacerti anche