Sei sulla pagina 1di 40

TECHNICAL HANDBOOK

FOR INDUSTRIAL SCREW


CONVEYORS

Via Oberdan Nr. 37 / 39


45037 Melara (Ro) ITALIA
Tel: 0425 / 89000 Fax: 0425 / 89698
e-mail: Pofersrl@tin.it

TABLE OF CONTENTS

1. GENERAL FEATURES___________________________ Errore. Il segnalibro non definito.


2. STANDARD COMPONENTS FOR SCREW CONVEYORS WITH MOTOR AT THE
INLET ____________________________________________ Errore. Il segnalibro non definito.
3. STANDARD COMPONENTS FOR SCREW CONVEYORS WITH MOTOR AT THE
OUTLET __________________________________________ Errore. Il segnalibro non definito.
4. OVERALL DIMENSIONS_________________________ Errore. Il segnalibro non definito.
5. STANDARD DIMENSIONS OF STRUCTURAL WORKSErrore. Il segnalibro non definito.
6. RUBBER COUPLING STOP EDGE FOR INLET AND OUTLET HATCHESErrore. Il segnalibro n
7. STANDARD DIMENSIONS OF INLET AND OUTLET HATCHESErrore. Il segnalibro non defin
8. DIMENSIONS OF ADJUSTABLE INLET HATCHES __ Errore. Il segnalibro non definito.
9. INLET AND OUTLET HATCH FLANGES ___________ Errore. Il segnalibro non definito.
10. FLANGE ON REDUCTION GEAR SIDE ____________ Errore. Il segnalibro non definito.
11. FLANGE ON NEUTRAL SIDE FOR SCREW CONVEYORS WITH REDUCTION
GEAR AT THE OUTLET_____________________________ Errore. Il segnalibro non definito.
12. FLANGE ON NEUTRAL SIDE_____________________ Errore. Il segnalibro non definito.
13. IN-BETWEEN SUPPORT _________________________ Errore. Il segnalibro non definito.
14. G.90 DRIVE OVERALL DIMENSIONS _________________________________________ 15
15. G.128 DRIVE OVERALL DIMENSIONS ________________________________________ 16
16. G.180 DRIVE OVERALL DIMENSIONS ________________________________________ 17
17. G.90 REDUCTION GEAR_____________________________________________________ 18
18. G.128 REDUCTION GEAR____________________________________________________ 19
19. G.180 REDUCTION GEAR____________________________________________________ 20
20. ELECTRIC MOTORS ____________________________ Errore. Il segnalibro non definito.
21. TECHNICAL FEATURES OF ELECTRIC MOTORS ___ Errore. Il segnalibro non definito.
22. INSPECTION DOOR_____________________________ Errore. Il segnalibro non definito.
23. LIFTING HOOKS _______________________________ Errore. Il segnalibro non definito.
24. LUBRICATOR PROTECTION ____________________ Errore. Il segnalibro non definito.
25. RUBBER COUPLING ____________________________ Errore. Il segnalibro non definito.
26. BASE SUPPORT ________________________________ Errore. Il segnalibro non definito.
27. THREADED FITTINGS __________________________ Errore. Il segnalibro non definito.
28. ADJUSTABLE SUPPORT_________________________ Errore. Il segnalibro non definito.
29. EXTENSION FOR ADJUSTABLE SUPPORTS________ Errore. Il segnalibro non definito.
30. IDENTIFICATION PLATE ________________________ Errore. Il segnalibro non definito.
31. TUBULAR SCREW CONVEYOR WEIGHT__________ Errore. Il segnalibro non definito.
32. HOURLY OUTPUT FOR SCREW CONVEYORS AT TOP SPEEDErrore. Il segnalibro non defin
33. HOURLY OUTPUT FOR SCREW CONVEYORS AT REDUCED SPEEDErrore. Il segnalibro non
34. HOURLY OUTPUT FOR SCREW CONVEYORS AT EXTREMELY REDUCED
SPEED Errore. Il segnalibro non definito.
35. HOURLY OUTPUT FOR SCREW CONVEYORS AT LOW SPEED ( R=1/15) __________ 37
36. HOURLY OUTPUT FOR SCREW CONVEYORS AT EXTREMELY LOW SPEED (
R=1/20) 38

1. GENERAL FEATURES
-Tubular screw conveyors are suited to draw, batch and handle concrete or concrete-like
materials.
-These conveyors have been developed according to all safety rules according to EC directives.
-They are available in different sizes in order to satisfy any capacity needs (139, 168, 193,
219, 273, 323)
-They are developed in big series and consist of interchangeable sectional parts being
connected one to each other by sturdy flangings to reach a total length approximately
equal to 12 - 13 metres.
-The extensions are equipped with sturdy in-between cast iron supports with plain bearing,
which is protected from wear by suitable seals as well as lubricated through special
lubricating points.
-The in-between splined bolt allows a quick coupling with the broached bushes welded at the
flight pipe end to occur creating in this way a perfectly balanced screw conveyor
movement.
-The standard flight is produced with reduced pitch at the inlet and normal pitch in the
remaining length, in order to avoid cloggings near the in-between supports and assure a
good functioning of the machine.
-The inspection doors are fixed to the screw conveyor pipe by the push of a bolt being screwed
on a bar, which levers on a protection welded on the pipe; such protection allows the door
to be fixed and hinders a water penetration in the inspection opening.
-Standard POFER reduction gear is directly splined on the flight shaft (at the inlet hatch) and is
equipped with an exclusive flanging contanining the seals.
-If the drive is mounted at the outlet, a head with an exclusive POFER sealing unit is mounted
at the inlet.
-Reduction gears are available with power from 1.1 kW to 15 kW and with reduction ratio 1/5,
1/7, 1/10, 1/15, 1/20 to meet different capacity needs.
-Only environment friendly paints are used according to the law being in force.
-A standard supply includes:
-cylindrical inlet and outlet hatches (one as inlet, one as outlet) with rubber coupling
edge;
-in-between flangings;
-inspection door under the inlet hatch and under every in-between support;
-in-between supports complete with lubricator and relevant protection;
-direct drive at the inlet;
-two lifting hooks for each screw conveyor piece;
-cable hose;
- chrome yellow RAL 1007 final painting; by request, different paintings can be carried
out;
-every conveyor is supplied with an EC declaration of compliance;
-adhesive labels indicating how to properly behave near dangerous areas.

2. STANDARD COMPONENTS FOR SCREW CONVEYORS


WITH MOTOR AT THE INLET
9
9
11
6
5
7
4

9
9
8

11
8

2
1

8
10

8
10
3

FIG 1

POS.

NAME

Motor

Pofer Reduction Gear

Flange at on reduction gear side

Flange on neutral side

In-between support

Screw conveyor housing

Flight

Cable hose

Lifting hook or eyebolt

10

Inspection door and cleaning

11

Identification serial plate

3. STANDARD COMPONENTS FOR SCREW CONVEYORS


WITH MOTOR AT THE OUTLET

1
2
3
9
9
11
6
5
9
7
9

11
8

4
10
8
10
3

FIG 2

POS.

NAME

Motor

Pofer Reduction Gear

Flange at on reduction gear side

Flange on neutral side

In-between support

Screw conveyor housing

Flight

Cable hose

Lifting hook or eyebolt

10

Inspection door and cleaning

11

Identification serial plate

4. OVERALL DIMENSIONS

C1

Li

C2

H
3

H
B

PARTICOLARE PER MOTORIZZAZIONE


MONTATA ALLO SCARICO
FIG 3

DIMENSIONS (mm)
T

139

168

193

219

273

323

230

230

265

300

355

425

139

168

193

219

273

323

139

168

193

219

273

323

SEE TABLE N 3

C1

120

140

150

160

180

220

C2

140

160

170

180

220

220

70

70

70

70

70

80

180

180

180

180

180

190

Li

BY REQUEST (Rounding off to 10 mm)

TABLE 1

5. STANDARD DIMENSIONS OF STRUCTURAL WORKS


DESCRIPTION
OUTER PIPE

DIAMETER (mm)
139

168

193

219

273

323

FLIGHT PIPE

48

60

60

60

60

90

Thickness (mm)

FLIGHT (mm)

115

140

160

190

240

300

Pitch at the inlet?

80

100

120

140

170

200

Working pitch

120

150

170

200

250

300

Pipe thickness (mm)

Thickness?
TABLE 2

? At the inlet the flight pitch is reduced to approximately 2/3 of the working pitch for a length

between 12 meters.
? The flight thickness is measured at approximately 2/3 of the section height from the point of

contact with the inner pipe.

6. RUBBER COUPLING STOP EDGE FOR INLET AND


OUTLET HATCHES

PART. Z
PART. Z
22

FIG 4
The rubber coupling stop edge is obtained from hatch rolling before the hatch is welded on the screw
conveyor. In case of additional loose ordered hatches, they are always supplied with rolled edge and
rust preventing painting.

7. STANDARD DIMENSIONS OF INLET AND OUTLET


HATCHES
-Standard inlet and outlet hatches are cylindrical and have a rubber coupling edge.
-The outlet hatch cannot have a diameter being smaller than the screw conveyor one.
-No screw conveyors with dimensions being smaller than the reported ones (see table) can be
ordered, unless our technical department communicates its approval.

H height (mm) according to inclination


HATCH
SCREW
CONVEYO
R
139

168

193

219

273

323

10 15 20 25 30 35 40 45

139

145

145

175

175

175

220

220

220

220

240

168

145

145

145

175

175

175

220

220

240

260

193

145

145

175

175

175

175

220

220

240

260

219

145

145

175

175

220

220

220

260

260

280

168

175

175

175

200

200

200

225

260

260

280

193

175

175

175

200

200

225

225

260

260

300

219

175

175

175

200

200

225

260

260

280

300

273

175

175

175

200

225

225

260

280

300

330

<193

175

175

200

200

225

225

250

275

275

300

193

175

175

200

200

225

225

250

275

275

300

219

175

175

200

200

225

250

250

275

300

325

273

175

200

200

225

225

250

275

300

325

350

323

175

200

200

225

250

250

275

300

350

375

<219

205

205

205

255

255

255

305

305

305

395

219

205

205

205

255

255

255

305

305

305

395

273

205

205

205

255

255

255

305

305

395

395

323

205

205

255

255

255

305

305

395

395

395

<273

250

250

250

250

300

300

350

350

400

400

273

250

250

250

250

300

300

350

350

400

400

323

250

250

250

300

300

300

350

350

400

450

356

250

250

250

300

300

350

350

400

400

450

<323

300

300

300

300

300

350

350

400

450

500

323

300

300

300

300

300

350

350

400

450

500

356

300

300

300

300

350

350

400

400

450

500

TABLE 3

8. DIMENSIONS OF ADJUSTABLE INLET HATCHES


A

FIG 5

DIMENSIONS (mm)
SCREW
CONVEYOR

30

<40

45

139

219
273
323
219
273
323
219
273
323
219
273
323
273
323
356
323
356
408

500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500

500
500
500
500
500
500
500
500
500
500
500
500
550
550
550
550
550
550

600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600

600
600
600
600
600
600
600
600
600
600
600
600
650
650
650
650
650
650

168

193

219

273

323

TABLE 4
?

CODE
770 051
770 055
770 060
770 051
770 055
770 060
770 251
770 255
770 260
770 451
770 455
770 460
770 651
770 655
770 660
770 810
770 815
770 820

9. INLET AND OUTLET HATCH FLANGES


FIG. 2
F

FIG. 1
F

A
B

B
C

FIG 6

DIMENSIONS (mm)
A

Th

Fig

Number
of holes

CODE

168

200

228

14

553 331

193

250

278

14

553 411*

219

250

278

14

553 491

273

300

328

14

553 611

323

350

378

14

553 691

356

400

440

14

553 731

406

470

530

14

553 771

TABLE 5
*The flange is not suitable for being connected with a 200 throttle valve
10

10. FLANGE ON REDUCTION GEAR SIDE


A

FIG 7

DESCRIPTION

CODE

Tail flange 139

770 042

Tail flange 168

770 082

Tail flange 193

770 282

Tail flange 219

770 482

Tail flange 273

770 682

Tail flange 323

770 882

TABLE 6

11

11. FLANGE ON NEUTRAL SIDE FOR SCREW


CONVEYORS WITH REDUCTION GEAR AT THE
OUTLET
A

FIG 8

DESCRIPTION

CODE

Flange and tail unit 139

770 040

Flange and tail unit 168

770 240

Flange and tail unit 193

770 440

Flange and tail unit 219

770 640

Flange and tail unit 273

770 690

Flange and tail unit 323

770 890

TABLE 7

12

12. FLANGE ON NEUTRAL SIDE


A

FIG 10

DESCRIPTION

CODE

Head flange 139

770 041

Head flange 168

770 081

Head flange 193

770 281

Head flange 219

770 481

Head flange 273

770 681

Head flange 323

770 881

TABLE 8

13

13. IN-BETWEEN SUPPORT


C

FIG 10

SCREW
CONVEYOR

CODE

139?

722 305

168

722 405

193

722 505

219

722 605

273

722 755

323?

722 856

TABLE 9
? Supports are not made of cast iron but of welded steel

14

14. G.90 DRIVE OVERALL DIMENSIONS

D
C
A

FIG 11

DIMENSIONS (mm)
REDUCTION
GEAR

kW

B?

F?

G.90 Pam 80

0.55

164

235

112

90

100

125

G.90 Pam 80

0.75

164

235

112

90

100

125

G.90 Pam 90 S

1.1

164

250

112

90

100

135

G.90 Pam 90 L

1.5

174

275

112

90

100

135

G.90 Pam 100 L

2.2

174

290

112

90

125

150

G.90 Pam 100 L

174

290

112

90

125

150

TABLE 10
? The B motor length can change 50 mm according to the motor mounted on the reduction gear.
? The terminal box height can change 20 mm according to the motor; it is possible to mount a

motor having a 90 rotated terminal board.


-Installed motors are three-phase motors with following voltage: 230/400 V up to 5.5 kW and at 50
Hz; 4 Poles (14001450 rpm), structural form: B5 (according to IEC rules), insulation class: F,
IP55 protection.
-By request and against payment, we can supply multitension, multifrequency and tropicalized
motors.
15

15. G.128 DRIVE OVERALL DIMENSIONS

D
C
A

FIG 12

DIMENSIONS (mm)
kW

B?

F?

196

335

148

128

125

150

G.128 Pam 132 S 4

5.5

221

370

148

128

150

175

G.128 Pam 132 MA 4

7.5

221

410

148

128

150

175

G.128 Pam 132 MB 4

9.2

221

410

148

128

150

225

G.128 Pam 160 M 4

11

221

520

148

128

175

225

G.128 Pam 160 L 4

15

221

520

148

128

175

225

REDUCTION
GEAR
G.128 Pam 112

TABLE 11
? The B motor length can change 50 mm according to the motor mounted on the reduction gear.
? The terminal box height can change 20 mm according to the motor; it is possible to mount a

motor having a 90 rotated terminal board.


-Installed motors are three-phase motors with following voltage: 230/400 V up to 5.5 kW and
400/690 V in case of more than 5.5 kW at 50 Hz; 4 Poles (14001450 rpm), structural form: B5
(according to IEC rules), insulation class: F, IP55 protection.
-By request and against payment, we can supply multitension, multifrequency and tropicalized
motors.
16

16. G.180 DRIVE OVERALL DIMENSIONS

D
C
A

FIG 13

DIMENSIONS (mm)
kW

B?

F?

G 180 Pam 90 S 4

1.1

250

250

110

180

100

125

G 180 Pam 90 B 4

1.5

250

275

110

180

100

125

G 180 Pam 100 LA 4

2.2

250

290

110

180

125

145

G 180 Pam 100 LB 4

3.0

250

290

110

180

125

145

G 180 Pam 112 N 4

4.0

250

335

110

180

125

150

G 180 Pam 132 S 4

5.5

280

370

110

180

150

175

G 180 Pam 132 MA 4

7.5

280

410

110

180

150

175

G 180 Pam 132 MB 4

9.2

280

410

110

180

150

175

G 180 Pam 160 M 4

11

280

520

110

180

175

230

G 180 Pam 160 L 4

15

280

520

110

180

175

230

REDUCTION
GEAR

TABLE 12
? The B motor length can change 50 mm according to the motor mounted on the reduction gear.

17

? The terminal box height can change 20 mm according to the motor; it is possible to mount a

motor having a 90 rotated terminal board.


-Installed motors are three-phase motors with following voltage: 230/400 V up to 5.5 kW and
400/690 V in case of more than 5.5 kW at 50 Hz; 4 Poles (14001450 rpm), structural form: B5
(according to IEC rules), insulation class: F, IP55 protection.
-By request and against payment, we can supply multitension, multifrequency and tropicalized
motors.

17. G.90 REDUCTION GEAR

FIG 14

Reduction Ratio
Power (kW)

Size

0.55

Pam 80 A

0.75

Pam 80 B 4

1.1

Pam 90 S 4

1.5

Pam 90 L 4

2.2

Pam 100 LA 4

3.0

Pam 100 LB 4

TABLE 13
? For 11 kW motors, only.
? For 5.5 kW motors, only.

18

1/5

1/7

1/10

391 100

391 140

391 180

391 104

391 144

391 184

391 108

391 148

391 188

Reduction gears are supplied with connection prearrangement to be connected with the motor
according to IEC rules related to electric motors developed in B5 form, with 4 poles; for different
motors (double speed 68 poles and so on), please contact POFER s.r.l.
Loose supplied reduction gears are painted with rust preventing paint.

18. G.128 REDUCTION GEAR

FIG 15

Reduction Ratio
Power (kW)

Size

4.0

Pam 112 M 4

5.5

Pam 132 S 4

7.5

Pam 132 MA 4

9.2

Pam 132 MB 4

11

Pam 160 M 4

15

Pam 160 L 4

TABLE 14
? For 11 kW motors, only.
? For 5.5 kW motors, only.
19

1/5

1/7

1/10

391 128

391 168

391 208

391 132

391 172

391 212

391 136

391 176

391 216

Reduction gears are supplied with prearrangement in order to be connected with the motor
according to IEC rules related to electric motors developed in B5 form, with 4 poles; for different
motors (double speed 68 poles and so on), please contact POFER s.r.l.
Loose supplied reduction gears are painted with rust preventing paint.

19. G.180 REDUCTION GEAR

FIG 16

Reduction Ratio
Power (kW)

Size

1.1

Pam 90 S 4

1.5

Pam 90 L 4

2.2

Pam 100 LA 4

3.0

Pam 100 LB 4

4.0

Pam 112 M 4

5.5

Pam 132 S 4

7.5

Pam 132 MA 4

9.2

Pam 132 MB 4

1/15

1/20

391 224

391 264

391 228

391 268

391 232

391 272
-

TABLE 15
20

? For 11 kW motors, only.


? For 5.5 kW motors, only.

Reduction gears are supplied with prearrangement in order to be connected with the motor
according to IEC rules related to electric motors developed in B5 form, with 4 poles; for different
motors (double speed 68 poles and so on), please contact POFER s.r.l.
Loose supplied reduction gears are painted with rust preventing paint.

20. ELECTRIC MOTORS

FIG 17

Power (kW)

Size

Standard code

ABB code

0.55

80 A 4

307 125

305 106

0.75

80 B 4

307 126

305 110

1.1

90 S 4

307 127

305 114

1.5

90 L 4

307 128

305 118

2.2

100 L 4

307 129

305 122

3.0

100 L 4

307 130

305 126

4.0

112 M 4

307 131

305 130

5.5

132 S 4

307 132

305 134

7.5

132 MA 4

307 153

305 088

9.2

132 MB 4

307 154

305 092

11

160 M 4

307 155

305 146

21

15

160 L 4

307 156

305 147

TABLE 16

21. TECHNICAL FEATURES OF ELECTRIC MOTORS


STANDARD MOTORS:
-Construction (according to IEC rules) in B5 form.
-Winding insulation in F class.
-Protection: IP 55.
-Voltage 230/400 V up to 5.5 kW, 400/690 V in case of more than 5.5 kW.
-Network frequency: 50 Hz.
-4 Poles (for a rotation speed between: 14001450 rpm).
The motors being mounted on the screw conveyor are painted in the same colour of the latter, in the
event a rust preventing paint is needed, motors will separately be supplied.
LEADING MARK MOTORS (ABB OR SIEMENS):
-Construction (according to IEC rules) in B5 form.
-Winding insulation in F class, tropicalized.
This treatment allows a remarkable electric as well as mechanical resistance and also high yield
and long life. The insulation protects winding from irritating gases, vapours, dust, oil and high air
humidity.
-Protection: IP 55 on whole motor.
-4 Pole version (for a rotation speed of 14001450 rpm)
-Voltage with 50 Hz network frequency:
for motors up to 5.5 kW 230/400 Volts
for motors from 7.5 kW 400/690 Volts.
-Voltage with 60 Hz network frequency:
for motors up to 5.5 kW compresi 270/480* Volts
for motors from 7.5 kW 480/830* Volts.
Please, consider that with a 60Hz functioning, speed of rotation and motor power have an
increase of approximately 20%
*Variable tensions slightly being different according to the motor mark
Motor is prepainted by the manufacturer, in order to be used in both indoors or outdoors; it can
continuously function in environments with 85% relative humidity with a maximum external
temperature of +25C, for short periods, it can also function with a 100% relative humidity and a
temperature up to 30C.

22

23

24

On thsi painting, an additional rust preventing coat and paint in the same colour as the screw
conveyor is applied in case the motor is mounted on the screw conveyor, only a rust preventing
coat is applied in case of separately supplied motors.

Note: for motors having different features (double speed motors, explosion-proof, self-braking
motors, motors with special tensions, etc.), please contact POFER s.r.l.

22. INSPECTION DOOR

25

FIG 18

CODE
SCREW
CONVEYOR

139

570 410

570 401

168

570 510

570 501

193

570 610

570 601

219

570 730

570 720

273

570 810

570 801

323

570 910

570 801

323 oversize

570 912

570 901

356

570 920

570 901

406

570 950

570 949

570 990

570 995

TABLE 17

The inspection door is easy to use and has a simple structure, it is placed near the inlet hatch and
every in-between support. Checks of the mechanical inner parts, their possible replacement in case of
wear or troubles as well as the inner cleaning of the screw conveyor after use can easily be carried
out.

26

23. LIFTING HOOKS

FIG 19
On any screw conveyor piece 2 lifting hooks are welded, they are useful to lift the screw
conveyor for both transporting it or fixing it by possible tie rods.
CODE: 570 101

24. LUBRICATOR PROTECTION

FIG 20
The in-between support lubricator protection is supplied with every screw conveyor and is painted in
the same colour as the latter; in case it is supplied in loose conditions, as a spare part, it has a rust
preventing coat.
CODE: 570 201

27

25. RUBBER COUPLING


BOCCA

FIG 21

HATCH (mm)
139
168
193
219
273
323

L (mm)

Th (mm)

CODE

300

470 221

500

470 222

300

470 321

500

470 322

300

470 401

500

470 402

300

470 481

500

470 482

300

470 601

500

470 602

300

470 681

500

470 682

TABLE 18
The order code includes 2 adjustable steel collars to fix the rubber coupling to the screw conveyor
inlet or outlet hatch.

28

26. BASE SUPPORT

*
Inclinazione

Inclinazione

FIG 22
*The hatch height can be made according to customers' request, provided that it is consistent with
inclination and screw conveyor drive type. The support is supplied complete with two threaded
fittings.

27. THREADED FITTINGS


63
A

30
16

40

A
FIG. 23
The pairs of threaded fittings are needed to fix the screw conveyor to the base support and can be
welded on both hatches and screw conveyor pipe.
CODE: 470 901
29

28. ADJUSTABLE SUPPORT

60

D
E C
20

82

FIG 24

DIMENSIONS (mm)
SCREW
CONVEYO
R

WEIGHT
(Kg)

CODE

139

139

240

125

225

150

2 .0

770 004

168

168

270

140

255

165

2.2

770 064

193

193

295

150

275

175

2.4

770 264

219

219

320

165

305

190

2.5

770 464

273

273

375

190

355

215

2.8

770 664

323

323

425

215

405

240

3.1

770 864

TABLE 19

The adjustable supports consist of sturdy half ring flangings screwed one to each other, which are
useful to fix tubular screw conveyors in order to avoid bendings and vibrations.
30

29. EXTENSION FOR ADJUSTABLE SUPPORTS

80

60

B
20
48

A
60

90
FIG 23

A (mm)

WEIGHT

Min

Max

(mm)

(Kg)

600

950

35

7.5

CODE

770 067

TABLE 20

The screw conveyor fixing occurs by screwing the adjustable support with the extension, which is
welded on a trestlework near the screw conveyor.

31

30. IDENTIFICATION PLATE

A456
145

/C

A456

001

/B

145

A456

001

145

/A
001

SEQUENZA DICOSTRUZIONE

CODICE MACCHINA

A000

/A

000

001

COMMESSA

Nr. PROGRESSIVO

FIG 24

The identification plate is positioned on each screw conveyor piece.


The plate reports: machine serial number, a letter indicating the assembling sequence of the pieces,
the order number and the construction progressive number, as well.
Please, remember that order number and machine serial number shall always be mentioned, in case
you need spare parts.

32

31. TUBULAR SCREW CONVEYOR WEIGHT


W1

W2

W3

FIG 25
W1 = Weight in Kgs of drive complete with motor head and inlet hatch.
W2 = Weight in Kg of outlet head + outlet hatch.
W3 = Weight in Kg per screw conveyor linear metre without drive, without outlet head and also
without inlet and outlet hatches.
m = Linear screw conveyor length (distance between centres in metres).

Pt = W1 + W2 + (W3 x m) = Total screw conveyor weight in Kg

WEIGHTS (Kgs)
kW

139

168

193

219

273

323

1.1

64

66

68

73

83

94

1.5

67

69

71

76

86

97

2,2

76

78

80

85

95

106

80

82

84

89

99

110

91

93

95

100

110

121

5,5

112

114

116

121

131

142

7,5

121

123

125

130

140

151

9,2

129

131

133

138

148

159

11

165

167

169

174

184

195

15

185

187

189

194

204

225

W2

18

18

21

28

37

48

W3

26

32

38

41

45

58

W1

33

TABLE 19

32. HOURLY OUTPUT FOR SCREW CONVEYORS AT TOP


SPEED
In the squares there are:
reduction ratio (1/...) / installed power (kW)

SCREW CONVEYOR DIAMETER


139

168

193

219

273

323

Length (mtrs)

15 t/h

25t/h

40t/h

60t/h

90t/h

110t/h

5 / 1,5

5 / 3,0

5 / 4,0

5 / 4,0

7 / 5,5

10 / 7,5

5 / 2,2

5 / 3,0

5 / 4,0

5 / 4,0

7 / 5,5

10 / 7,5

5 / 2,2

5 / 4,0

5 / 4,0

5 / 5,5

7 / 5,5

10 / 9,2

5 / 2,2

5 / 4,0

5 / 4,0

5 / 5,5

7 / 7,5

10 / 9,2

5 / 3,0

5 / 4,0

5 / 5,5

5 / 5,5

7 / 7,5

10 / 11

5 / 3,0

5 / 4,0

5 / 5,5

5 / 7,5

7 / 9,2

10 / 11

5 / 3,0

5 / 5,5

5 / 5,5

5 / 7,5

7 / 9,2

10 / 15

5 / 4,0

5 / 5,5

5 / 7,5

5 / 9,2

7 / 11

10 / 15

5 / 4,0

5 / 5,5

5 /7,5

5 / 9,2

7 / 11

---

10

---

5 / 7,5

5 / 7,5

5 / 9,2

7 / 11

---

11

---

5 / 7,5

5 / 7,5

5 / 11

7 / 15

---

12

---

5 / 7,5

5 / 9,2

5 / 11

7 / 15

---

13

---

5 / 7,5

5 / 9,2

5 / 11

7 / 15

---

TABLE 20

-Capacities have been calculated considering concrete with specific weight equal to 1,13 t/m3as
material to be conveyed.
-The installed power refers to electric three-phase motors having following technical features:
-voltage 230/400 V up to 5.5 kW and 400/690V for motors from 7.5 kW with a 50Hz network
frequency.
-4 poles (for a speed of rotation of 14001450 rpm).
-Installation under 1000 m above sea level, at ambient temperatures between -20 e i +40 C.

34

33. HOURLY OUTPUT FOR SCREW CONVEYORS AT


REDUCED SPEED
In the squares there are:
reduction ratio (1/...) / installed power (kW)

SCREW CONVEYOR DIAMETER


139

168

193

219

273

Length (mtrs)

10 t/h

17t/h

27t/h

40t/h

67t/h

7 / 1,5

7 / 2,2

7 / 2,2

7 / 4,0

10 / 5,5

7 / 1,5

7 / 2,2

7 / 3,0

7 / 4,0

10 / 5,5

7 / 1,5

7 / 2,2

7 / 3,0

7 / 4,0

10 / 5,5

7 / 2,2

7 / 3,0

7 / 4,0

7 / 5,5

10 / 7,5

7 / 2,2

7 / 3,0

7 / 4,0

7 / 5,5

10 / 7,5

7 / 2,2

7 / 3,0

7 / 4,0

7 / 5,5

10 / 9,2

7 / 3,0

7 / 4,0

7 / 4,0

7 / 7,5

10 / 9,2

7 / 3,0

7 / 4,0

7 / 5,5

7 / 7,5

10 / 9,2

7 / 3,0

7 / 4,0

7 / 5,5

7 / 9,2

10 / 11

10

---

7 / 4,0

7 / 5,5

7 / 9,2

10 / 11

11

---

7 / 4,0

7 / 5,5

7 / 9,2

10 / 15

12

---

7 / 4,0

7 / 7,5

7 / 11

10 / 15

13

---

7 / 4,0

7 / 7,5

7 / 11

10 / 15

TABLE 21

-Capacities have been calculated considering concrete with specific weight equal to 1,13 t/m3as
material to be conveyed.
-The installed power refers to electric three-phase motors having following technical features:
-voltage 230/400 V up to 5.5 kW and 400/690V for motors from 7.5 kW with a 50Hz network
frequency.
-4 poles (for a speed of rotation of 14001450 rpm).
-Installation under 1000 m above sea level, at ambient temperatures between -20 e i +40 C.

35

34. HOURLY OUTPUT FOR SCREW CONVEYORS AT


EXTREMELY REDUCED SPEED
In the squares there are:
reduction ratio (1/...) / installed power (kW)

SCREW CONVEYOR DIAMETER


139

168

193

219

Length (mtrs)

7,5 t/h

12,5 t/h

20 t/h

30 t/h

10 / 1,5

10 / 1,5

10 / 2,2

10 / 3,0

10 / 1,5

10 / 2,2

10 / 3,0

10 / 4,0

10 / 1,5

10 / 2,2

10 / 3,0

10 / 4,0

10 / 2,2

10 / 3,0

10 / 4,0

10 / 4,0

10 / 2,2

10 / 3,0

10 / 4,0

10 / 5,5

10 / 2,2

10 / 3,0

10 / 4,0

10 / 5,5

10 / 2,2

10 / 3,0

10 / 4,0

10 / 7,5

10 / 2,2

10 / 4,0

10 / 4,0

10 / 7,5

---

10 / 4,0

10 / 5,5

10 / 9,2

10

---

10 / 4,0

10 / 5,5

10 / 9,2

11

---

10 / 4,0

10 / 5,5

10 / 9,2

12

---

10 / 4,0

10 / 7,5

10 / 11

13

---

10 / 4,0

10 / 7,5

10 / 11

TABLE 22

-Capacities have been calculated considering concrete with specific weight equal to 1,13 t/m3as
material to be conveyed.
-The installed power refers to electric three-phase motors having following technical features:
-voltage 230/400 V up to 5.5 kW and 400/690V for motors from 7.5 kW with a 50Hz network
frequency.
-4 poles (for a speed of rotation of 14001450 rpm).
-Installation under 1000 m above sea level, at ambient temperatures between -20 e i +40 C.

36

35. HOURLY OUTPUT FOR SCREW CONVEYORS AT LOW


SPEED ( R=1/15)
In the squares there are:
reduction ratio (1/...) / installed power (kW)

SCREW CONVEYOR DIAMETER


139

168

193

219

273

323

Length (mtrs)

5 t/h

8 t/h

13 t/h

20 t/h

42 t/h

73 t/h

15 / 0,55

15 / 1,1

15 / 1,1

15 / 1,1

15 /2,2

15 / 5,5

15 / 0,75

15 / 1,1

15 / 1,5

15 / 1,5

15 / 2,2

15 / 5,5

15 / 0,75

15 / 1,5

15 / 1,5

15 / 1,5

15 / 3,0

15 / 5,5

15 / 0,75

15 / 1,5

15 / 1,5

15 / 1,5

15 / 3,0

15 / 5,5

15 / 1,1

15 / 1,5

15 / 1,5

15 / 2,2

15 / 4,0

15 / 7,5

15 / 1,1

15 / 2,2

15 / 2,2

15 / 2,2

15 / 4,0

15 / 7,5

15 / 1,1

15 / 2,2

15 / 2,2

15 / 2,2

15 / 4,0

15 / 7,5

15 / 1,5

15 / 2,2

15 / 2,2

15 / 3,0

15 / 5,5

15 / 9,2

15 / 1,5

15 / 2,2

15 / 2,2

15 / 3,0

15 / 5,5

15 / 9,2

10

---

15 / 2,2

15 / 2,2

15 / 3,0

15 / 5,5

15 / 9,2

11

---

15 / 2,2

15 / 2,2

15 / 3,0

15 / 5,5

15 / 9,2

12

---

15 / 2,2

15 / 3,0

15 / 4,0

15 / 7,5

---

13

---

15 / 2,2

15 / 3,0

15 / 4,0

15 / 7,5

---

TABLE 23

-Capacities have been calculated considering concrete with specific weight equal to 1,13 t/m3as
material to be conveyed.
-The installed power refers to electric three-phase motors having following technical features:
-voltage 230/400 V up to 5.5 kW and 400/690V for motors from 7.5 kW with a 50Hz network
frequency.
-4 poles (for a speed of rotation of 14001450 rpm).
-Installation under 1000 m above sea level, at ambient temperatures between -20 e i +40 C.

37

36. HOURLY OUTPUT FOR SCREW CONVEYORS AT


EXTREMELY LOW SPEED ( R=1/20)
In the squares there are:
reduction ratio (1/...) / installed power (kW)

SCREW CONVEYOR DIAMETER


139

168

193

219

273

323

Lungh. (mt.)

4 t/h

6 t/h

10 t/h

15 t/h

33 t/h

55 t/h

20 / 0,55

20 / 0,75

20 / 1,1

20 / 1,1

20 / 2,2

20 / 4,0

20 / 0,55

20 / 0,75

20 / 1,1

20 / 1,1

20 / 2,2

20 / 4,0

20 / 0,55

20 / 1,1

20 / 1,1

20 / 1,5

20 / 2,2

20 / 4,0

20 / 0,55

20 / 1,1

20 / 1,1

20 / 1,5

20 / 3,0

20 / 5.5

20 / 0,75

20 / 1,1

20 / 1,5

20 / 1,5

20 / 3,0

20 / 5.5

20 / 0,75

20 / 1,1

20 / 1,5

20 / 2,2

20 / 4,0

20 / 7.5

20 / 0,75

20 / 1,5

20 / 1,5

20 / 2,2

20 / 4,0

20 / 7.5

20 / 1,1

20 / 1,5

20 / 2,2

20 / 2,2

20 / 4,0

20 / 7.5

20 / 1,1

20 / 1,5

20 / 2,2

20 / 2,2

20 / 4,0

20 / 7.5

10

---

20 / 2,2

20 / 2,2

20 / 2,2

20 / 4,0

20 / 7.5

11

---

20 / 2,2

20 / 2,2

20 / 3,0

20 / 5.5

---

12

---

20 / 2,2

20 / 2,2

20 / 3,0

20 / 5.5

---

13

---

20 / 2,2

20 / 2,2

20 / 3,0

20 / 5.5

---

TABLE 24

-Capacities have been calculated considering concrete with specific weight equal to 1,13 t/m3as
material to be conveyed.
-The installed power refers to electric three-phase motors having following technical features:
-voltage 230/400 V up to 5.5 kW and 400/690V for motors from 7.5 kW with a 50Hz network
frequency.
-4 poles (for a speed of rotation of 14001450 rpm).
-Installation under 1000 m above sea level, at ambient temperatures between -20 e i +40 C.

38

Composition and print:


Pofer s.r.l.
45037 Melara (Rovigo) - via Oberdan 37/39
e-mail pofersrl@tin.it o info@pofer.it
http://www.pofer.it

Revisione 01 del 072004

39

Potrebbero piacerti anche