MEDIUM DUTY LOGIC

USER'S GUIDE

MH 5011U MT 5011U
MHS 5011U BMT 5011U

MGJ 5011U MJ 5011U

CONTACT INFORMATION

Radio Receiver
Built on Board

Installation Date

www.liftmaster.com
315 MHz
INTRODUCTION
Congratulations on purchasing a quality, LiftMaster Medium Duty Commercial Door Operator. Your new operator is capable of operating
up to 12 cycles per hour or 50 cycles per day. It is equipped with a built in radio receiver that is compatible with our existing 315 MHz
product line as well as a Timer-to-Close (TTC) feature that can be enabled when LiftMaster Commercial Protector System® is installed
and aligned properly.

BASIC PROGRAMMING
DETERMINE THE WIRING TYPE
The functionality of this operator is based on the wiring type. The operator is shipped from the factory in standard C2 wiring type
(factory default). LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) DEVICE IS REQUIRED.
NOTES:
• The LED on the logic board will blink once when in C2 and twice when in B2.
• The operator will automatically convert to B2 wiring when Monitored Entrapment Protection Device is installed. If the Monitored
Entrapment Protection Device is removed, the operator will go into a Restricted Close mode**. Turn power OFF and ON to reset wiring
type.
** Restricted close mode requires a constant pressure close command. The operator will begin closing after a 5 second delay and will
continue to close to the close limit switch. The operator will stop if the pressure to close is released before reaching the close limit.

RECOMMENDED INSTALLATION: B2 WIRING TYPE WITH


MONITORED ENTRAPMENT PROTECTION DEVICE

• Momentary contact to open, close and stop.


• Open override that reverses when closing by any opening
device.
• Wiring for entrapment protection device to reverse.
NOTE: The operator will automatically convert to B2 wiring
when Monitored Entrapment Protection Device is installed. (See
accessories page for Monitored Entrapment Protection Devices.)
• Timer-to-Close (TTC) feature available.

No Programming Required
MONITORED ENTRAPMENT PROTECTION DEVICE

Photoelectric Sensor

2
BASIC PROGRAMMING
DETERMINE THE WIRING TYPE

ALTERNATE INSTALLATION: C2 WIRING TYPE WITH MONITORED ALTERNATE INSTALLATION: C2 WIRING TYPE WITHOUT
ENTRAPMENT PROTECTION DEVICE MONITORED ENTRAPMENT PROTECTION DEVICE
(FACTORY DEFAULT)
• Momentary contact to open and stop with constant pressure to • Momentary contact to open and stop with constant pressure to
close. close.
• Open override that reverses when closing by any opening • Open override that reverses when closing by any opening
device. device.
• Wiring for entrapment protection device to reverse. • Wiring for entrapment protection device to reverse.
NOTE: The operator will automatically convert to B2 wiring NOTE: The operator will automatically convert to B2 wiring
when Monitored Entrapment Protection Device is installed. (See when Monitored Entrapment Protection Device is installed.
accessories page for Monitored Entrapment ProtectionDevices.) (See accessories page for Monitored Entrapment Protection
• Timer-to-Close (TTC) feature not available. Devices.)
• Timer-to-Close (TTC) feature not available.

MONITORED ENTRAPMENT PROTECTION DEVICE NON-MONITORED ENTRAPMENT PROTECTION DEVICE

Photoelectric Sensor Sensing Edge

To Program: Reset to FACTORY DEFAULT (C2) without Monitored Entrapment


Press and hold the LEARN and CLOSE buttons until the LED Protection Device:
1 goes out (approximately 3 seconds).

Electrical Box Logic Board


1 Remove any monitored entrapment protection devices.
2 Press and hold the LEARN and STOP buttons until LED goes
out (approximately 3 seconds).
D7 D5
U4 D6 D4
J4
014A1030 C32
C20
TP1 R25
C9
C31

U1
C21

LEARN STOP CLOSE OPEN


L5
^^^^
AUX
AUX ANT
ANT
C18

J2 R27

D14
K2
TTC LEARN STOP CLOSE OPEN LT

LED C29
R24

D14
1 2 3 4 5 6 7
P1

D9
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
LED

1 2 3 4 5 6 7

To Reset to B2 with Monitored Entrapment Protection Device:


1 Press and hold the LEARN and STOP buttons until the LED
goes out (approximately 3 seconds).

3
BASIC PROGRAMMING

WARNING
To prevent possible SEVERE INJURY or DEATH:
• Install a LiftMaster Monitored Entrapment Protection (LMEP) • Activate door ONLY when it can be seen clearly, is properly
device. CAUTION
adjusted and there are no obstructions to door travel.
• NEVER permit children to operate or play with door control • ALWAYS keep door in sight until completely closed. NEVER
push buttons or remote controls. permit anyone to cross the path of closing door.

RADIO OPERATION
MODE OPEN CLOSE STOP REVERSE WHILE TTC RESET
CLOSING
B2 X X X X
B2 with TTC X X (3-button remote) X X X when open
C2 X X X

AVERTISSEMENT AVE
REMOTE CONTROLS
Built in 315 MHz radio receiver permits as many as 20 Security✚® remote controls or dip switch remote controls in any combination. ATTENTION AV

SINGLE BUTTON REMOTE CONTROL


1 2 Press and hold the button on the remote control until the LED
flashes rapidly, then release to complete programming (LED
TTC
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

will go out).
R27
1

Press and release


LED

the LEARN button


2
AUX ANT

D14
AUX
AUX ANT

ANT
TTC

^^^^
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

(LED will light).


LEARN
LED
2

D14

3
LEARN
3
4

STOP
5

CLOSE OPEN
6
7

STOP
5

CLOSE OPEN
6
7

Repeat steps 1 and 2 for additional remote controls.

3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION


NOTE: The feature will use 3 of the 20 memory channels in the operator.
1 2 3 Press and hold the desired button of the remote
TTC
TTC

ADVERTENCIA Press the desired


control until LED flashes rapidly, then release.
AD
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

R27
R27

1
1

Press and hold button on the logic


LED
LED

2
2

the LEARN button


AUX ANT

D14
D14

board (OPEN,
AUX
AUX ANT

ANT
TTC

^^^^
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

LEARN
LEARN

(LED will light).


LED
2

3
D14

3
LEARN
3
4

CLOSE or STOP).
STOP
5

CLOSE OPEN
6
7

4
4

Release both
STOP
STOP

PRECAUCIÓN A
5
5

buttons.
CLOSE OPEN
CLOSE OPEN

6
6

7
7

Repeat steps 1 through 3 to program additional buttons.

TO ERASE ALL REMOTE CONTROLS


1
TTC

Press and hold the


LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

R27
1

LEARN button (over


LED
2

5 seconds) until the


AUX ANT

D14
AUX
AUX ANT

ANT
TTC

^^^^
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

LEARN
LED
2

D14

LED goes out. All


LEARN
3
4

STOP
5

CLOSE OPEN
6
7

programmed remote
4

STOP

controls will be
5

CLOSE OPEN

erased.
6
7

4
BASIC PROGRAMMING
TIMER-TO-CLOSE (TTC)
Timer-to-Close feature enables the operator to close from the open limit after a preset time, adjustable from 5 to 60 seconds. Requires
LiftMaster Monitored Entrapment Protection (LMEP) device.

TO PROGRAM
Begin with door in fully closed position.

1 2 Press and
3 Every press and release
4 Press and release
TTC

release the of the STOP button

TTC

TTC
the TTC button to

TTC
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

will add 5 seconds to

LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN


R27

TTC button.

LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN


1

R27

R27
Press and exit programming

R27
1
the Timer-to-Close. mode. The LED
LED
2

release the

LED

LED
2

2
AUX ANT

LED
D14

2
AUX
AUX ANT

ANT

Example: 30 second

D14

D14
TTC

D14
^^^^
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

will flash once per


1

LEARN

LEARN button
LED
2

D14

3
LEARN

LEARN

LEARN
3

3
4

STOP

LEARN
5

3
TTC = 6 presses of the
CLOSE OPEN
6
7

(LED will light). 5 seconds of timer


4

4
STOP

STOP button.

4
STOP

STOP
setting.

STOP
5

5
CLOSE OPEN

CLOSE OPEN

CLOSE OPEN

CLOSE OPEN
6

6
7

7
The TTC will become active after completion of the next open cycle. NOTE: The LED does not indicate that timer is running.

TO VERIFY TIMER-TO-CLOSE (TTC) SETTING

1 2 Press and 3 Press and release the TTC button a


TTC

release the
TTC

second time. The LED will flash once

TTC
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

R27

LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

TTC button.
1

LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN


per 5 seconds of timer setting.
R27

Press and hold

R27
1

1
LED
2

the LEARN button


AUX ANT

LED
2

LED
D14
AUX

2
AUX ANT

ANT

D14
TTC

^^^^

D14
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

LEARN

(LED will light).


LED
2

D14

3
LEARN
3

LEARN
4

STOP

LEARN
5

3
CLOSE OPEN
6
7

STOP

4
STOP

STOP
5

5
CLOSE OPEN

CLOSE OPEN

CLOSE OPEN
6

6
7

CLEAR THE TIMER-TO-CLOSE (TTC)


1 2 Press and hold 3 Release the
TTC

TTC button
TTC

the TTC button


TTC
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

(LED will go
R27

LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

R27

for 6 seconds.
1

1
R27

Press and
1

out). The TCC


LED
2

release the
LED
2
LED
AUX ANT

2
D14
AUX
AUX ANT

D14
ANT

will no longer
D14
TTC

^^^^
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

LEARN

LEARN button
LED
2

LEARN
D14

3
LEARN

3
3

LEARN
4

STOP

3
5

CLOSE OPEN

be active.
6
7

(LED will light).


4

4
STOP

STOP
STOP
5

5
5
CLOSE OPEN

CLOSE OPEN
CLOSE OPEN
6

6
6
7

7
7

TIMER DEFEAT
The TTC can be temporarily disabled by pressing a STOP button. TTC will become enabled after the next open command.

5
NG TESTING WARNING

N WARNING
To avoid SERIOUS personal INJURY or DEATH:
• Disconnect electric power BEFORE performing ANY • ALL maintenance MUST be performed by a trained door
adjustments or maintenance. systems technician.

Turn on power, LED will flash 4 times on power up. Test all controls and entrapment protection devices to make sure they are working
properly. It may be necessary to refer back to the Adjustment section for adjustment of the limits.
IMPORTANT NOTES:
• Do not leave power to the operator on unless all entrapment protection devices have been tested and are working properly.
• Be sure you have read and understand all safety instructions included in this manual.
• Be sure the owner or person(s) responsible for operation of the door have read and understand the safety instructions, know how to
electrically operate the door in a safe manner and how to manually disconnect the door from the operator.
EMENT AVERTISSEMENT
TEST 3-BUTTON CONTROL STATION TEST THE ENTRAPMENT PROTECTION DEVICES

ON 1 Press OPEN button. (The door should move in the AVERTISSEMENT


open 1 Open the door.
direction.)

2 Press STOP button. (The door should stop.) 2 Place an obstruction in the path of the photoelectric sensors
or sensing edge.

3 Press CLOSE button. (The door should move in the close


direction.)
3 Press the CLOSE button. The door should not close if
photoelectric sensors are installed. The door should close to
obstruction and reverse if sensing edge is installed.
4 Release CLOSE button. Door should stop if in C2 mode.
(The door should continue closing if in B2 mode.) 4 Remove the obstruction.
5 Press STOP button. (The door should stop.) 5 Press CLOSE button. Door should close.
If door did not reverse from obstruction, check entrapment
protection devices.
TEST LIMIT ADJUSTMENT

NCIA1 Press OPEN button. (The door should open.) ADVERTENCIA


TEST REMOTE CONTROL
2 Allow the door to fully open.
Requires B2 wiring type and compatible LiftMaster remote control.
ÓN ADVERTENCIA
In C2 wiring the remote control will open the door only.
3 Press CLOSE button. (The door should close.)
1 Press remote control button.
4 Allow the door to fully close.
2 Door should open. Allow the door to fully open.
If the limits are not set properly, remove power and adjust limits
(refer to installation manual). 3 Press remote control button.
4 Door should close. Allow door to fully close.

6
EMERGENCY DISCONNECT
The operators have provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate
instructions for your model operator.

WARNING W
To prevent possible SERIOUS INJURY or DEATH from a falling
door or arm:
CAUTION
• DO NOT stand under the door arm when pulling the emergency • NEVER use emergency release handle unless doorway is clear
release. of persons and obstructions.
• If possible, use emergency release handle to disengage trolley
ONLY when door is CLOSED. Weak or broken springs or
unbalanced door could result in an open door falling rapidly
and/or unexpectedly.

MODEL MT/BMT

TO DISCONNECT DOOR FROM OPERATOR

1 Pull emergency release handle straight down. Emergency


disconnect will open. AVERTISSEMENT AVE
Emergency
Disconnect
Emergency
Disconnect ATTENTION AVE
Door Arm

TO RECONNECT DOOR ARM TO TROLLEY NOTI


CE Emergency
Release Handle
1 Lift free end of door arm to trolley. Door

2 Pull emergency release handle to allow arm to engage roll


pin.

3 Let go of the emergency release handle. Emergency


disconnect will close.
ADVERTENCIA AD

PRECAUCIÓN AD
Emergency
Disconnect

Door Arm

7
NG EMERGENCY DISCONNECT
WARNING

N WARNING
To prevent possible SERIOUS INJURY from a moving chain:
• DISCONNECT electric power to the operator BEFORE manually • NEVER use emergency disconnect unless doorway is clear of
operating your door. persons and obstructions.
• If possible, use emergency disconnect ONLY when door is
CLOSED. Weak or broken springs or unbalanced door could
result in an open door falling rapidly and/or unexpectedly.

MODEL MH MODELS MJ AND MGJ


These operators are equipped with a manual hoist. An electrical This operator has a floor level disconnect chain to disconnect the
interlock will disable the electrical controls when the hoist is used. door from the door operator.

EMENT
1 Pull the disconnect chain (sash chain) to engageAVERTISSEMENT
the hoist
mechanism. The disconnect chain may be locked in position
1 To disengage, pull the chain and secure in the disengaged
position by slipping the end through the keyhole bracket
by slipping the end through the keyhole of the chain keeper mounted on the wall. Or if emergency egress device is used,
mounted on the wall. pull handle to disengage operator from door.
ON AVERTISSEMENT
2 Operate the door in the desired direction by pulling on one 2 The door may now be pushed up or pulled down manually.
side or the other of the continuous loop hoist chain.
Release the disconnect chain or reset the emergency egress
The disconnect chain must be released from the chain keeper
3 device to operate the door again electrically.
3 before the door will operate again electrically.
MODEL MHS
EMERGENCY DISCONNECT FOR MODELS MJ
The MHS operator includes both a floor level disconnect sash
chain to disconnect the door from the door operator that allows
manual push up operation and an additional sash chain to engage
Keyhole Bracket
the manual chain hoist that also electrically disables the operator
controls.

1 Refer to Model MH instructions for hoist operation.


2 Refer to Model MJ instructions for emergency operation.
NCIA ADVERTENCIA
When the manual chain hoist sash chain is engaged, electrical
operation will not function.
ÓN ELECTRICAL INTERLOCK WITH HOIST FOR MODELS MH AND MHS
ADVERTENCIA
Chain Keeper
(with pad locking provisions)

8
TROUBLESHOOTING
To locate a dealer in your area visit us online at www.liftmaster.com.

CONDITION POSSIBLE CAUSE FIX


OPERATOR WILL NOT
RESPOND TO ANY No power ➤ Check circuit breaker.
COMMANDS
Accessory failure ➤ Verify photoelectric sensors are aligned.
Possible component failure ➤ Contact your installing dealer.
OPERATOR MAKES
NOISE BUT DOOR Operator requires adjustment ➤ Contact your installing dealer.
DOES NOT MOVE
DOOR DRIFTS AFTER Operator or door requires
➤ Contact your installing dealer.
OPERATOR STOPS adjustment
DOOR OPENS/CLOSES
Operator requires adjustment ➤ Contact your installing dealer.
TOO FAR
➤ Verify photoelectric sensors are aligned. If photoelectric sensors are
DOOR REVERSES Entrapment protection device
aligned and operator still does not operate properly, contact your
UNEXPECTEDLY activated
installing dealer.
RADIO FUNCTIONALITY
Remote control is not
NO RESPONSE ➤ See PROGRAMMING REMOTE CONTROLS section.
programmed
Low battery ➤ Replace battery.
REMOTE CANNOT BE
Low battery ➤ Replace battery.
PROGRAMMED
POOR RANGE Low battery in remote ➤ Replace battery.
Possible radio interference ➤ Contact your installing dealer.

NG MAINTENANCE SCHEDULEWARNING

N WARNING
To avoid SERIOUS personal INJURY or DEATH from
electrocution, disconnect ALL electric power BEFORE performing
ANY maintenance.

Every 3 months or 5,000 cycles repeat all tests in the Testing section.
Call qualified service contractor for maintenance. To locate a dealer in your area visit us online at www.liftmaster.com.

The operator should be serviced at the following intervals:


• Every 3 months or 5,000 cycles
• Every 6 months or 10,000 cycles
EMENT• Every 12 months or 20,000 cycles AVERTISSEMENT

ON AVERTISSEMENT

9
OPERATOR NOTES

10
ACCESSORIES
REMOTE CONTROLS 315 MHZ ENTRAPMENT PROTECTION DEVICES
®
LiftMaster offers a variety of SECURITY✚ CPS-UN4
Remote Controls for your application needs. Commercial Protector System:
Single to 4-Button, visor or key chain. Contact
LiftMaster Monitored Entrapment Protection
your authorized dealer.
(LMEP) provides protection on doors up to 45'
371LM wide. NEMA-4 rated.
1-Button SECURITY✚® Remote Control: CPS-U
Includes visor clip.
Commercial Protector System:
373LM
LiftMaster Monitored Entrapment Protection
3-Button SECURITY✚® Remote Control: (LMEP) provides protection on doors up to
OPEN

Includes visor clip. 30' wide. CLOSE

333LM CPS-EI CPS-EI


E1

3-Button Tri-Colored Dip Switch Remote Monitored Sensing Edge Interface: E2


LMEP2

LMEP1
E3

Control: Requires 4-wire monitored sensing edge. E4


40-34141-1

Open/Close/Stop functionality. Includes visor


clip. 65ME1234
WPB1LM3
OPEN
Miller ME123 4-Wire Monitored Safety Edge:
Wireless Single Push Button Control
For sectional or rolling doors.
SECURITY✚®:
Rugged composite housing. (Wireless controls 65ME110
cannot be used in place of hard wired controls.)
Miller ME110 4-Wire Monitored Safety Edge:
WPB3LM3 For rolling grilles and counter shutters.

Wireless 3 Button Control Station


SECURITY✚®:
Rugged composite housing. (Wireless controls MOUNTING BRACKETS
cannot be used in place of hard wired controls.)
10-12360
WKP5LM3 (5 4-digit entry codes) Mounting Brackets:
WKP250LM3 (250 4-digit entry codes) Angle mounting bracket, Painted steel, for MJ,
MH, and MHS.
Wireless Access Control Keypads 1
4 5
2 3
6

SECURITY✚®: 7
*
8
0
9
#

Rugged composite housing. (Wireless controls 10-9095


cannot be used in place of hard wired controls.) Medium Duty Angle Mounting Bracket:
Heavy-gauge steel bracket. May be welded.
CONTROL STATIONS For use with MJ, MGJ, and MH operators.

02-102
OPEN

2-Button Control Station: CLOSE

Steel enclosure. CHAIN TENSIONERS For Jackshaft Type


Operators
02-103 71-6023
OPEN

^
3-Button Control Station:
OP
EN

CLOSE ^
CLOS

O
E

Chain Tensioner:
Steel enclosure.
STOP

For 1" shafts


02-109 71-6125
OPEN CLOSE

Key Control Station: Chain Tensioner:


Indoor flush mount, NEMA 1. For 1-1/2" shafts

11
ACCESSORIES

FIELD MODIFICATION KITS ANTENNA


71MLSBC EXT-ANT
Single Button Control: Antenna:
Provides additional input for Single Button Control functionality. External kit for medium duty.
Input functions as Close input when the operator is stopped at
the Open limit. Input functions as Open input at all other times. 86LM (15')
Also used with external radio controls. 86LMT (25')
71 MLMOTION
Antenna Extension Kit:
Door-In-Motion: The antenna extension kit can be used with
Provides dry contact and a terminal block with contacts EXT-ANT for maximum radio receiver range.
switched to power an auxiliary device while the door is in
motion.

© 2010, The Chamberlain Group, Inc.


01-34006B All Rights Reserved