Sei sulla pagina 1di 88

Protective Devices

Miniature Circuit Breakers PLSM, PLZM


MW
High-quality miniature circuit breakers for commercial and residential applications
Contact position indicator red - green
Guide for secure terminal connection
3-position DIN rail clip, permits removal from existing busbar system
Comprehensive range of accessories suitable for subsequent installation
Rated currents up to 63 A
Tripping characteristics B, C, D
Rated breaking capacity 10 kA according to IEC/EN 60898-1

SG67811

111

Protective Devices
Miniature Circuit Breakers PLSM, PLZM
10 kA, Characteristic B
Rated current In (A)
SG48411

Type Designation

Article No.

Units per package

PLSM-B1
PLSM-B1,5
PLSM-B1,6
PLSM-B2
PLSM-B2,5
PLSM-B3
PLSM-B3,5
PLSM-B4
PLSM-B5
PLSM-B6
PLSM-B8
PLSM-B10
PLSM-B12
PLSM-B13
PLSM-B15
PLSM-B16
PLSM-B20
PLSM-B25
PLSM-B32
PLSM-B40
PLSM-B50
PLSM-B63

242165
242166
242167
242168
242169
242170
242171
242172
242173
242174
242175
242176
242177
242178
242179
242180
242181
242182
242183
242184
242185
242186

12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120

1+N-pole, 1.5 Module Units (MU)


1
PLSM-B1/1N
1.5
PLSM-B1,5/1N
1.6
PLSM-B1,6/1N
2
PLSM-B2/1N
2.5
PLSM-B2,5/1N
3
PLSM-B3/1N
3.5
PLSM-B3,5/1N
4
PLSM-B4/1N
5
PLSM-B5/1N
6
PLSM-B6/1N
8
PLSM-B8/1N
10
PLSM-B10/1N
12
PLSM-B12/1N
13
PLSM-B13/1N
15
PLSM-B15/1N
16
PLSM-B16/1N
20
PLSM-B20/1N
25
PLSM-B25/1N
32
PLSM-B32/1N

242234
242235
242236
242237
242238
242239
242240
242241
242242
242243
242244
242245
242246
242247
242248
242249
242250
242251
242252

8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80

1+N-pole, 2 Module Units (MU)


1
PLZM-B1/1N
1.5
PLZM-B1,5/1N
1.6
PLZM-B1,6/1N
2
PLZM-B2/1N
2.5
PLZM-B2,5/1N
3
PLZM-B3/1N
3.5
PLZM-B3,5/1N
4
PLZM-B4/1N
5
PLZM-B5/1N
6
PLZM-B6/1N
8
PLZM-B8/1N
10
PLZM-B10/1N
12
PLZM-B12/1N
13
PLZM-B13/1N
15
PLZM-B15/1N
16
PLZM-B16/1N
20
PLZM-B20/1N
25
PLZM-B25/1N
32
PLZM-B32/1N
40
PLZM-B40/1N
50
PLZM-B50/1N
63
PLZM-B63/1N

242295
242296
242297
242298
242299
242300
242301
242302
242303
242304
242305
242306
242307
242308
242309
242310
242311
242312
242313
242314
242315
242316

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

SG49211

SG52711

Explanation PLSM:
P = XPole, LS = MCB, M = 10 kA

MW

112

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLSM-B1/2
PLSM-B1,5/2
PLSM-B1,6/2
PLSM-B2/2
PLSM-B2,5/2
PLSM-B3/2
PLSM-B3,5/2
PLSM-B4/2
PLSM-B5/2
PLSM-B6/2
PLSM-B8/2
PLSM-B10/2
PLSM-B12/2
PLSM-B13/2
PLSM-B15/2
PLSM-B16/2
PLSM-B20/2
PLSM-B25/2
PLSM-B32/2
PLSM-B40/2
PLSM-B50/2
PLSM-B63/2

242364
242365
242366
242367
242368
242369
242370
242371
242372
242373
242374
242375
242376
242377
242378
242379
242380
242381
242382
242383
242384
242385

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PLSM-B1/3
PLSM-B1,5/3
PLSM-B1,6/3
PLSM-B2/3
PLSM-B2,5/3
PLSM-B3/3
PLSM-B3,5/3
PLSM-B4/3
PLSM-B5/3
PLSM-B6/3
PLSM-B8/3
PLSM-B10/3
PLSM-B12/3
PLSM-B13/3
PLSM-B15/3
PLSM-B16/3
PLSM-B20/3
PLSM-B25/3
PLSM-B32/3
PLSM-B40/3
PLSM-B50/3
PLSM-B63/3

242433
242434
242435
242436
242437
242438
242439
242440
242441
242442
242443
242444
242445
242446
242447
242448
242449
242450
242451
242452
242453
242454

1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40

3+N-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PLSM-B1/3N
PLSM-B1,5/3N
PLSM-B1,6/3N
PLSM-B2/3N
PLSM-B2,5/3N
PLSM-B3/3N
PLSM-B3,5/3N
PLSM-B4/3N
PLSM-B5/3N
PLSM-B6/3N
PLSM-B8/3N
PLSM-B10/3N
PLSM-B12/3N
PLSM-B13/3N
PLSM-B15/3N
PLSM-B16/3N
PLSM-B20/3N
PLSM-B25/3N
PLSM-B32/3N
PLSM-B40/3N
PLSM-B50/3N
PLSM-B63/3N

242502
242503
242504
242505
242506
242507
242508
242509
242510
242511
242512
242513
242514
242515
242516
242517
242518
242519
242520
242521
242522
242523

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

2-pole
SG54811

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63
SG63111

SG65611

Explanation PLSM:
P = XPole, LS = MCB, M = 10 kA

3-pole

113

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLSM-B1/4
PLSM-B1,5/4
PLSM-B1,6/4
PLSM-B2/4
PLSM-B2,5/4
PLSM-B3/4
PLSM-B3,5/4
PLSM-B4/4
PLSM-B5/4
PLSM-B6/4
PLSM-B8/4
PLSM-B10/4
PLSM-B12/4
PLSM-B13/4
PLSM-B15/4
PLSM-B16/4
PLSM-B20/4
PLSM-B25/4
PLSM-B32/4
PLSM-B40/4
PLSM-B50/4
PLSM-B63/4

242571
242572
242573
242574
242575
242576
242577
242578
242579
242580
242581
242582
242583
242584
242585
242586
242587
242588
242589
242590
242591
242592

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

4-pole
SG67811

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Miniature Circuit Breakers PLSM, PLZM


10 kA, Characteristic C
Rated current In (A)
SG48411

Type Designation

Article No.

Units per package

PLSM-C0,16
PLSM-C0,25
PLSM-C0,5
PLSM-C0,75
PLSM-C1
PLSM-C1,5
PLSM-C1,6
PLSM-C2
PLSM-C2,5
PLSM-C3
PLSM-C3,5
PLSM-C4
PLSM-C5
PLSM-C6
PLSM-C8
PLSM-C10
PLSM-C12
PLSM-C13
PLSM-C15
PLSM-C16
PLSM-C20
PLSM-C25
PLSM-C32
PLSM-C40
PLSM-C50
PLSM-C63

242187
242188
242190
242189
242191
242192
242193
242194
242195
242196
242197
242198
242199
242200
242201
242202
242203
242204
242205
242206
242207
242208
242209
242210
242211
242212

12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120

1-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLSM:
P = XPole, LS = MCB, M = 10 kA

MW

114

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLSM-C0,16/1N
PLSM-C0,25/1N
PLSM-C0,5/1N
PLSM-C0,75/1N
PLSM-C1/1N
PLSM-C1,5/1N
PLSM-C1,6/1N
PLSM-C2/1N
PLSM-C2,5/1N
PLSM-C3/1N
PLSM-C3,5/1N
PLSM-C4/1N
PLSM-C5/1N
PLSM-C6/1N
PLSM-C8/1N
PLSM-C10/1N
PLSM-C12/1N
PLSM-C13/1N
PLSM-C15/1N
PLSM-C16/1N
PLSM-C20/1N
PLSM-C25/1N
PLSM-C32/1N

242253
242254
242256
242255
242257
242258
242259
242260
242261
242262
242263
242264
242265
242266
242267
242268
242269
242270
242271
242272
242273
242274
242275

8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80

PLZM-C0,16/1N
PLZM-C0,25/1N
PLZM-C0,5/1N
PLZM-C0,75/1N
PLZM-C1/1N
PLZM-C1,5/1N
PLZM-C1,6/1N
PLZM-C2/1N
PLZM-C2,5/1N
PLZM-C3/1N
PLZM-C3,5/1N
PLZM-C4/1N
PLZM-C5/1N
PLZM-C6/1N
PLZM-C8/1N
PLZM-C10/1N
PLZM-C12/1N
PLZM-C13/1N
PLZM-C15/1N
PLZM-C16/1N
PLZM-C20/1N
PLZM-C25/1N
PLZM-C32/1N
PLZM-C40/1N
PLZM-C50/1N
PLZM-C63/1N

242317
242318
242320
242319
242321
242322
242323
242324
242325
242326
242327
242328
242329
242330
242331
242332
242333
242334
242335
242336
242337
242338
242339
242340
242341
242342

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1+N-pole, 1.5 MU
SG49211

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32

SG52711

1+N-pole, 2 MU
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLSM:
P = XPole, LS = MCB, M = 10 kA

115

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLSM-C0,16/2
PLSM-C0,25/2
PLSM-C0,5/2
PLSM-C0,75/2
PLSM-C1/2
PLSM-C1,5/2
PLSM-C1,6/2
PLSM-C2/2
PLSM-C2,5/2
PLSM-C3/2
PLSM-C3,5/2
PLSM-C4/2
PLSM-C5/2
PLSM-C6/2
PLSM-C8/2
PLSM-C10/2
PLSM-C12/2
PLSM-C13/2
PLSM-C15/2
PLSM-C16/2
PLSM-C20/2
PLSM-C25/2
PLSM-C32/2
PLSM-C40/2
PLSM-C50/2
PLSM-C63/2

242386
242387
242389
242388
242390
242391
242392
242393
242394
242395
242396
242397
242398
242399
242400
242401
242402
242403
242404
242405
242406
242407
242408
242409
242410
242411

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

PLSM-C0,16/3
PLSM-C0,25/3
PLSM-C0,5/3
PLSM-C0,75/3
PLSM-C1/3
PLSM-C1,5/3
PLSM-C1,6/3
PLSM-C2/3
PLSM-C2,5/3
PLSM-C3/3
PLSM-C3,5/3
PLSM-C4/3
PLSM-C5/3
PLSM-C6/3
PLSM-C8/3
PLSM-C10/3
PLSM-C12/3
PLSM-C13/3
PLSM-C15/3
PLSM-C16/3
PLSM-C20/3
PLSM-C25/3
PLSM-C32/3
PLSM-C40/3
PLSM-C50/3
PLSM-C63/3

242455
242456
242458
242457
242459
242460
242461
242462
242463
242464
242465
242466
242467
242468
242469
242470
242471
242472
242473
242474
242475
242476
242477
242478
242479
242480

1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40

2-pole
SG54811

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63
3-pole
SG63111

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLSM:
P = XPole, LS = MCB, M = 10 kA

116

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLSM-C0,16/3N
PLSM-C0,25/3N
PLSM-C0,5/3N
PLSM-C0,75/3N
PLSM-C1/3N
PLSM-C1,5/3N
PLSM-C1,6/3N
PLSM-C2/3N
PLSM-C2,5/3N
PLSM-C3/3N
PLSM-C3,5/3N
PLSM-C4/3N
PLSM-C5/3N
PLSM-C6/3N
PLSM-C8/3N
PLSM-C10/3N
PLSM-C12/3N
PLSM-C13/3N
PLSM-C15/3N
PLSM-C16/3N
PLSM-C20/3N
PLSM-C25/3N
PLSM-C32/3N
PLSM-C40/3N
PLSM-C50/3N
PLSM-C63/3N

242524
242525
242527
242526
242528
242529
242530
242531
242532
242533
242534
242535
242536
242537
242538
242539
242540
242541
242542
242543
242544
242545
242546
242547
242548
242549

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

PLSM-C0,16/4
PLSM-C0,25/4
PLSM-C0,5/4
PLSM-C0,75/4
PLSM-C1/4
PLSM-C1,5/4
PLSM-C1,6/4
PLSM-C2/4
PLSM-C2,5/4
PLSM-C3/4
PLSM-C3,5/4
PLSM-C4/4
PLSM-C5/4
PLSM-C6/4
PLSM-C8/4
PLSM-C10/4
PLSM-C12/4
PLSM-C13/4
PLSM-C15/4
PLSM-C16/4
PLSM-C20/4
PLSM-C25/4
PLSM-C32/4
PLSM-C40/4
PLSM-C50/4
PLSM-C63/4

242593
242594
242596
242595
242597
242598
242599
242600
242601
242602
242603
242604
242605
242606
242607
242608
242609
242610
242611
242612
242613
242614
242615
242616
242617
242618

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

3+N-pole
SG65611

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63
4-pole
SG67811

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLSM:
P = XPole, LS = MCB, M = 10 kA

117

Protective Devices
Miniature Circuit Breakers PLSM, PLZM
10 kA, Characteristic D
Rated current In (A)
SG48411

SG49211

SG52711

Explanation PLSM:
P = XPole, LS = MCB, M = 10 kA

MW

Type Designation

Article No.

Units per package

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PLSM-D0,5
PLSM-D1
PLSM-D1,5
PLSM-D1,6
PLSM-D2
PLSM-D2,5
PLSM-D3
PLSM-D3,5
PLSM-D4
PLSM-D5
PLSM-D6
PLSM-D8
PLSM-D10
PLSM-D12
PLSM-D13
PLSM-D15
PLSM-D16
PLSM-D20
PLSM-D25
PLSM-D32
PLSM-D40

242213
242214
242215
242216
242217
242218
242219
242220
242221
242222
242223
242224
242225
242226
242227
242228
242229
242230
242231
242232
242233

12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120

1+N-pole, 1.5 MU
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25

PLSM-D0,5/1N
PLSM-D1/1N
PLSM-D1,5/1N
PLSM-D1,6/1N
PLSM-D2/1N
PLSM-D2,5/1N
PLSM-D3/1N
PLSM-D3,5/1N
PLSM-D4/1N
PLSM-D5/1N
PLSM-D6/1N
PLSM-D8/1N
PLSM-D10/1N
PLSM-D12/1N
PLSM-D13/1N
PLSM-D15/1N
PLSM-D16/1N
PLSM-D20/1N
PLSM-D25/1N

242276
242277
242278
242279
242280
242281
242282
242283
242284
242285
242286
242287
242288
242289
242290
242291
242292
242293
242294

8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80

1+N-pole, 2 MU
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PLZM-D0,5/1N
PLZM-D1/1N
PLZM-D1,5/1N
PLZM-D1,6/1N
PLZM-D2/1N
PLZM-D2,5/1N
PLZM-D3/1N
PLZM-D3,5/1N
PLZM-D4/1N
PLZM-D5/1N
PLZM-D6/1N
PLZM-D8/1N
PLZM-D10/1N
PLZM-D12/1N
PLZM-D13/1N
PLZM-D15/1N
PLZM-D16/1N
PLZM-D20/1N
PLZM-D25/1N
PLZM-D32/1N
PLZM-D40/1N

242343
242344
242345
242346
242347
242348
242349
242350
242351
242352
242353
242354
242355
242356
242357
242358
242359
242360
242361
242362
242363

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1-pole

118

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLSM-D0,5/2
PLSM-D1/2
PLSM-D1,5/2
PLSM-D1,6/2
PLSM-D2/2
PLSM-D2,5/2
PLSM-D3/2
PLSM-D3,5/2
PLSM-D4/2
PLSM-D5/2
PLSM-D6/2
PLSM-D8/2
PLSM-D10/2
PLSM-D12/2
PLSM-D13/2
PLSM-D15/2
PLSM-D16/2
PLSM-D20/2
PLSM-D25/2
PLSM-D32/2
PLSM-D40/2

242412
242413
242414
242415
242416
242417
242418
242419
242420
242421
242422
242423
242424
242425
242426
242427
242428
242429
242430
242431
242432

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PLSM-D0,5/3
PLSM-D1/3
PLSM-D1,5/3
PLSM-D1,6/3
PLSM-D2/3
PLSM-D2,5/3
PLSM-D3/3
PLSM-D3,5/3
PLSM-D4/3
PLSM-D5/3
PLSM-D6/3
PLSM-D8/3
PLSM-D10/3
PLSM-D12/3
PLSM-D13/3
PLSM-D15/3
PLSM-D16/3
PLSM-D20/3
PLSM-D25/3
PLSM-D32/3
PLSM-D40/3

242481
242482
242483
242484
242485
242486
242487
242488
242489
242490
242491
242492
242493
242494
242495
242496
242497
242498
242499
242500
242501

1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40

3+N-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PLSM-D0,5/3N
PLSM-D1/3N
PLSM-D1,5/3N
PLSM-D1,6/3N
PLSM-D2/3N
PLSM-D2,5/3N
PLSM-D3/3N
PLSM-D3,5/3N
PLSM-D4/3N
PLSM-D5/3N
PLSM-D6/3N
PLSM-D8/3N
PLSM-D10/3N
PLSM-D12/3N
PLSM-D13/3N
PLSM-D15/3N
PLSM-D16/3N
PLSM-D20/3N
PLSM-D25/3N
PLSM-D32/3N
PLSM-D40/3N

242550
242551
242552
242553
242554
242555
242556
242557
242558
242559
242560
242561
242562
242563
242564
242565
242566
242567
242568
242569
242570

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

2-pole
SG54811

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
3-pole
SG63111

SG65611

Explanation PLSM:
P = XPole, LS = MCB, M = 10 kA

119

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLSM-D0,5/4
PLSM-D1/4
PLSM-D1,5/4
PLSM-D1,6/4
PLSM-D2/4
PLSM-D2,5/4
PLSM-D3/4
PLSM-D3,5/4
PLSM-D4/4
PLSM-D5/4
PLSM-D6/4
PLSM-D8/4
PLSM-D10/4
PLSM-D12/4
PLSM-D13/4
PLSM-D15/4
PLSM-D16/4
PLSM-D20/4
PLSM-D25/4
PLSM-D32/4
PLSM-D40/4

242619
242620
242621
242622
242623
242624
242625
242626
242627
242628
242629
242630
242631
242632
242633
242634
242635
242636
242637
242638
242639

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

4-pole
SG67811

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

Explanation PLSM:
P = XPole, LS = MCB, M = 10 kA

120

Protective Devices

Miniature Circuit Breakers PLS6, PLZ6


MW
High-quality miniature circuit breakers for commercial and residential
applications
Contact position indicator red - green
Guide for secure terminal connection
3-position DIN rail clip, permits removal from existing busbar system
Comprehensive range of accessories suitable for subsequent installation
Rated currents up to 63 A
Tripping characteristics B, C, D
Rated breaking capacity 6 kA according to IEC/EN 60898-1

SG72911

121

Protective Devices
Miniature Circuit Breakers PLS6, PLZ6
6 kA, Characteristic B
Rated current In (A)
SG26911

Type Designation

Article No.

Units per package

PLS6-B1
PLS6-B1,5
PLS6-B1,6
PLS6-B2
PLS6-B2,5
PLS6-B3
PLS6-B3,5
PLS6-B4
PLS6-B5
PLS6-B6
PLS6-B8
PLS6-B10
PLS6-B12
PLS6-B13
PLS6-B15
PLS6-B16
PLS6-B20
PLS6-B25
PLS6-B32
PLS6-B40
PLS6-B50
PLS6-B63

242640
242641
242642
242643
242644
242645
242646
242647
242648
242649
242650
242651
242652
242653
242654
242655
242656
242657
242658
242659
242660
242661

12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120

1+N-pole, 1.5 Module Units (MU)


1
PLS6-B1/1N
1.5
PLS6-B1,5/1N
1.6
PLS6-B1,6/1N
2
PLS6-B2/1N
2.5
PLS6-B2,5/1N
3
PLS6-B3/1N
3.5
PLS6-B3,5/1N
4
PLS6-B4/1N
5
PLS6-B5/1N
6
PLS6-B6/1N
8
PLS6-B8/1N
10
PLS6-B10/1N
12
PLS6-B12/1N
13
PLS6-B13/1N
15
PLS6-B15/1N
16
PLS6-B16/1N
20
PLS6-B20/1N
25
PLS6-B25/1N
32
PLS6-B32/1N

242709
242710
242711
242712
242713
242714
242715
242716
242717
242718
242719
242720
242721
242722
242723
242724
242725
242726
242727

8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80

1+N-pole, 2 Module Units (MU)


1
PLZ6-B1/1N
1.5
PLZ6-B1,5/1N
1.6
PLZ6-B1,6/1N
2
PLZ6-B2/1N
2.5
PLZ6-B2,5/1N
3
PLZ6-B3/1N
3.5
PLZ6-B3,5/1N
4
PLZ6-B4/1N
5
PLZ6-B5/1N
6
PLZ6-B6/1N
8
PLZ6-B8/1N
10
PLZ6-B10/1N
12
PLZ6-B12/1N
13
PLZ6-B13/1N
15
PLZ6-B15/1N
16
PLZ6-B16/1N
20
PLZ6-B20/1N
25
PLZ6-B25/1N
32
PLZ6-B32/1N
40
PLZ6-B40/1N
50
PLZ6-B50/1N
63
PLZ6-B63/1N

242770
242771
242772
242773
242774
242775
242776
242777
242778
242779
242780
242781
242782
242783
242784
242785
242786
242787
242788
242789
242790
242791

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

SG40111

SG58211

Explanation PLS6:
P = XPole, LS = MCB, 6 = 6 kA

MW

122

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS6-B1/2
PLS6-B1,5/2
PLS6-B1,6/2
PLS6-B2/2
PLS6-B2,5/2
PLS6-B3/2
PLS6-B3,5/2
PLS6-B4/2
PLS6-B5/2
PLS6-B6/2
PLS6-B8/2
PLS6-B10/2
PLS6-B12/2
PLS6-B13/2
PLS6-B15/2
PLS6-B16/2
PLS6-B20/2
PLS6-B25/2
PLS6-B32/2
PLS6-B40/2
PLS6-B50/2
PLS6-B63/2

242839
242840
242841
242842
242843
242844
242845
242846
242847
242848
242849
242850
242851
242852
242853
242854
242855
242856
242857
242858
242859
242860

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PLS6-B1/3
PLS6-B1,5/3
PLS6-B1,6/3
PLS6-B2/3
PLS6-B2,5/3
PLS6-B3/3
PLS6-B3,5/3
PLS6-B4/3
PLS6-B5/3
PLS6-B6/3
PLS6-B8/3
PLS6-B10/3
PLS6-B12/3
PLS6-B13/3
PLS6-B15/3
PLS6-B16/3
PLS6-B20/3
PLS6-B25/3
PLS6-B32/3
PLS6-B40/3
PLS6-B50/3
PLS6-B63/3

242908
242909
242910
242911
242912
242913
242914
242915
242916
242917
242918
242919
242920
242921
242922
242923
242924
242925
242926
242927
242928
242929

1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40

3+N-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PLS6-B1/3N
PLS6-B1,5/3N
PLS6-B1,6/3N
PLS6-B2/3N
PLS6-B2,5/3N
PLS6-B3/3N
PLS6-B3,5/3N
PLS6-B4/3N
PLS6-B5/3N
PLS6-B6/3N
PLS6-B8/3N
PLS6-B10/3N
PLS6-B12/3N
PLS6-B13/3N
PLS6-B15/3N
PLS6-B16/3N
PLS6-B20/3N
PLS6-B25/3N
PLS6-B32/3N
PLS6-B40/3N
PLS6-B50/3N
PLS6-B63/3N

242977
242978
242979
242980
242981
242982
242983
242984
242985
242986
242987
242988
242989
242990
242991
242992
242993
242994
242995
242996
242997
242998

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

2-pole
SG55411

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63
SG74311

SG73911

Explanation PLS6:
P = XPole, LS = MCB, 6 = 6 kA

3-pole

123

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS6-B1/4
PLS6-B1,5/4
PLS6-B1,6/4
PLS6-B2/4
PLS6-B2,5/4
PLS6-B3/4
PLS6-B3,5/4
PLS6-B4/4
PLS6-B5/4
PLS6-B6/4
PLS6-B8/4
PLS6-B10/4
PLS6-B12/4
PLS6-B13/4
PLS6-B15/4
PLS6-B16/4
PLS6-B20/4
PLS6-B25/4
PLS6-B32/4
PLS6-B40/4
PLS6-B50/4
PLS6-B63/4

243046
243047
243048
243049
243050
243051
243052
243053
243054
243055
243056
243057
243058
243059
243060
243061
243062
243063
243064
243065
243066
243067

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

4-pole
SG72911

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Miniature Circuit Breakers PLS6, PLZ6


6 kA, Characteristic C
Rated current In (A)
SG26911

Type Designation

Article No.

Units per package

PLS6-C0,16
PLS6-C0,25
PLS6-C0,5
PLS6-C0,75
PLS6-C1
PLS6-C1,5
PLS6-C1,6
PLS6-C2
PLS6-C2,5
PLS6-C3
PLS6-C3,5
PLS6-C4
PLS6-C5
PLS6-C6
PLS6-C8
PLS6-C10
PLS6-C12
PLS6-C13
PLS6-C15
PLS6-C16
PLS6-C20
PLS6-C25
PLS6-C32
PLS6-C40
PLS6-C50
PLS6-C63

242662
242663
242665
242664
242666
242667
242668
242669
242670
242671
242672
242673
242674
242675
242676
242677
242678
242679
242680
242681
242682
242683
242684
242685
242686
242687

12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120

1-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLS6:
P = XPole, LS = MCB, 6 = 6 kA

MW

124

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS6-C0,16/1N
PLS6-C0,25/1N
PLS6-C0,5/1N
PLS6-C0,75/1N
PLS6-C1/1N
PLS6-C1,5/1N
PLS6-C1,6/1N
PLS6-C2/1N
PLS6-C2,5/1N
PLS6-C3/1N
PLS6-C3,5/1N
PLS6-C4/1N
PLS6-C5/1N
PLS6-C6/1N
PLS6-C8/1N
PLS6-C10/1N
PLS6-C12/1N
PLS6-C13/1N
PLS6-C15/1N
PLS6-C16/1N
PLS6-C20/1N
PLS6-C25/1N
PLS6-C32/1N

242728
242729
242731
242730
242732
242733
242734
242735
242736
242737
242738
242739
242740
242741
242742
242743
242744
242745
242746
242747
242748
242749
242750

8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80

PLZ6-C0,16/1N
PLZ6-C0,25/1N
PLZ6-C0,5/1N
PLZ6-C0,75/1N
PLZ6-C1/1N
PLZ6-C1,5/1N
PLZ6-C1,6/1N
PLZ6-C2/1N
PLZ6-C2,5/1N
PLZ6-C3/1N
PLZ6-C3,5/1N
PLZ6-C4/1N
PLZ6-C5/1N
PLZ6-C6/1N
PLZ6-C8/1N
PLZ6-C10/1N
PLZ6-C12/1N
PLZ6-C13/1N
PLZ6-C15/1N
PLZ6-C16/1N
PLZ6-C20/1N
PLZ6-C25/1N
PLZ6-C32/1N
PLZ6-C40/1N
PLZ6-C50/1N
PLZ6-C63/1N

242792
242793
242795
242794
242796
242797
242798
242799
242800
242801
242802
242803
242804
242805
242806
242807
242808
242809
242810
242811
242812
242813
242814
242815
242816
242817

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1+N-pole, 1.5 MU
SG40111

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
1+N-pole, 2 MU
SG58211

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLS6:
P = XPole, LS = MCB, 6 = 6 kA

125

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS6-C0,16/2
PLS6-C0,25/2
PLS6-C0,5/2
PLS6-C0,75/2
PLS6-C1/2
PLS6-C1,5/2
PLS6-C1,6/2
PLS6-C2/2
PLS6-C2,5/2
PLS6-C3/2
PLS6-C3,5/2
PLS6-C4/2
PLS6-C5/2
PLS6-C6/2
PLS6-C8/2
PLS6-C10/2
PLS6-C12/2
PLS6-C13/2
PLS6-C15/2
PLS6-C16/2
PLS6-C20/2
PLS6-C25/2
PLS6-C32/2
PLS6-C40/2
PLS6-C50/2
PLS6-C63/2

242861
242862
242864
242863
242865
242866
242867
242868
242869
242870
242871
242872
242873
242874
242875
242876
242877
242878
242879
242880
242881
242882
242883
242884
242885
242886

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

PLS6-C0,16/3
PLS6-C0,25/3
PLS6-C0,5/3
PLS6-C0,75/3
PLS6-C1/3
PLS6-C1,5/3
PLS6-C1,6/3
PLS6-C2/3
PLS6-C2,5/3
PLS6-C3/3
PLS6-C3,5/3
PLS6-C4/3
PLS6-C5/3
PLS6-C6/3
PLS6-C8/3
PLS6-C10/3
PLS6-C12/3
PLS6-C13/3
PLS6-C15/3
PLS6-C16/3
PLS6-C20/3
PLS6-C25/3
PLS6-C32/3
PLS6-C40/3
PLS6-C50/3
PLS6-C63/3

242930
242931
242933
242932
242934
242935
242936
242937
242938
242939
242940
242941
242942
242943
242944
242945
242946
242947
242948
242949
242950
242951
242952
242953
242954
242955

1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40

2-pole
SG55411

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63
3-pole
SG74311

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLS6:
P = XPole, LS = MCB, 6 = 6 kA

126

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS6-C0,16/3N
PLS6-C0,25/3N
PLS6-C0,5/3N
PLS6-C0,75/3N
PLS6-C1/3N
PLS6-C1,5/3N
PLS6-C1,6/3N
PLS6-C2/3N
PLS6-C2,5/3N
PLS6-C3/3N
PLS6-C3,5/3N
PLS6-C4/3N
PLS6-C5/3N
PLS6-C6/3N
PLS6-C8/3N
PLS6-C10/3N
PLS6-C12/3N
PLS6-C13/3N
PLS6-C15/3N
PLS6-C16/3N
PLS6-C20/3N
PLS6-C25/3N
PLS6-C32/3N
PLS6-C40/3N
PLS6-C50/3N
PLS6-C63/3N

242999
243000
243002
243001
243003
243004
243005
243006
243007
243008
243009
243010
243011
243012
243013
243014
243015
243016
243017
243018
243019
243020
243021
243022
243023
243024

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

PLS6-C0,16/4
PLS6-C0,25/4
PLS6-C0,5/4
PLS6-C0,75/4
PLS6-C1/4
PLS6-C1,5/4
PLS6-C1,6/4
PLS6-C2/4
PLS6-C2,5/4
PLS6-C3/4
PLS6-C3,5/4
PLS6-C4/4
PLS6-C5/4
PLS6-C6/4
PLS6-C8/4
PLS6-C10/4
PLS6-C12/4
PLS6-C13/4
PLS6-C15/4
PLS6-C16/4
PLS6-C20/4
PLS6-C25/4
PLS6-C32/4
PLS6-C40/4
PLS6-C50/4
PLS6-C63/4

243068
243069
243071
243070
243072
243073
243074
243075
243076
243077
243078
243079
243080
243081
243082
243083
243084
243085
243086
243087
243088
243089
243090
243091
243092
243093

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

3+N-pole
SG73911

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63
4-pole
SG72911

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLS6:
P = XPole, LS = MCB, 6 = 6 kA

127

Protective Devices
Miniature Circuit Breakers PLS6, PLZ6
6 kA, Characteristic D
Rated current In (A)
SG26911

SG40111

SG58211

Explanation PLS6:
P = XPole, LS = MCB, 6 = 6 kA

MW

Type Designation

Article No.

Units per package

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PLS6-D1
PLS6-D1,5
PLS6-D1,6
PLS6-D2
PLS6-D2,5
PLS6-D3
PLS6-D3,5
PLS6-D4
PLS6-D5
PLS6-D6
PLS6-D8
PLS6-D10
PLS6-D12
PLS6-D13
PLS6-D15
PLS6-D16
PLS6-D20
PLS6-D25
PLS6-D32
PLS6-D40

242689
242690
242691
242692
242693
242694
242695
242696
242697
242698
242699
242700
242701
242702
242703
242704
242705
242706
242707
242708

12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120

1+N-pole, 1.5 MU
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25

PLS6-D0,5/1N
PLS6-D1/1N
PLS6-D1,5/1N
PLS6-D1,6/1N
PLS6-D2/1N
PLS6-D2,5/1N
PLS6-D3/1N
PLS6-D3,5/1N
PLS6-D4/1N
PLS6-D5/1N
PLS6-D6/1N
PLS6-D8/1N
PLS6-D10/1N
PLS6-D12/1N
PLS6-D13/1N
PLS6-D15/1N
PLS6-D16/1N
PLS6-D20/1N
PLS6-D25/1N

242751
242752
242753
242754
242755
242756
242757
242758
242759
242760
242761
242762
242763
242764
242765
242766
242767
242768
242769

8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80
8 / 80

1+N-pole, 2 MU
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PLZ6-D0,5/1N
PLZ6-D1/1N
PLZ6-D1,5/1N
PLZ6-D1,6/1N
PLZ6-D2/1N
PLZ6-D2,5/1N
PLZ6-D3/1N
PLZ6-D3,5/1N
PLZ6-D4/1N
PLZ6-D5/1N
PLZ6-D6/1N
PLZ6-D8/1N
PLZ6-D10/1N
PLZ6-D12/1N
PLZ6-D13/1N
PLZ6-D15/1N
PLZ6-D16/1N
PLZ6-D20/1N
PLZ6-D25/1N
PLZ6-D32/1N
PLZ6-D40/1N

242818
242819
242820
242821
242822
242823
242824
242825
242826
242827
242828
242829
242830
242831
242832
242833
242834
242835
242836
242837
242838

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1-pole

128

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS6-D0,5/2
PLS6-D1/2
PLS6-D1,5/2
PLS6-D1,6/2
PLS6-D2/2
PLS6-D2,5/2
PLS6-D3/2
PLS6-D3,5/2
PLS6-D4/2
PLS6-D5/2
PLS6-D6/2
PLS6-D8/2
PLS6-D10/2
PLS6-D12/2
PLS6-D13/2
PLS6-D15/2
PLS6-D16/2
PLS6-D20/2
PLS6-D25/2
PLS6-D32/2
PLS6-D40/2

242887
242888
242889
242890
242891
242892
242893
242894
242895
242896
242897
242898
242899
242900
242901
242902
242903
242904
242905
242906
242907

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PLS6-D0,5/3
PLS6-D1/3
PLS6-D1,5/3
PLS6-D1,6/3
PLS6-D2/3
PLS6-D2,5/3
PLS6-D3/3
PLS6-D3,5/3
PLS6-D4/3
PLS6-D5/3
PLS6-D6/3
PLS6-D8/3
PLS6-D10/3
PLS6-D12/3
PLS6-D13/3
PLS6-D15/3
PLS6-D16/3
PLS6-D20/3
PLS6-D25/3
PLS6-D32/3
PLS6-D40/3

242956
242957
242958
242959
242960
242961
242962
242963
242964
242965
242966
242967
242968
242969
242970
242971
242972
242973
242974
242975
242976

1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40

3+N-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PLS6-D0,5/3N
PLS6-D1/3N
PLS6-D1,5/3N
PLS6-D1,6/3N
PLS6-D2/3N
PLS6-D2,5/3N
PLS6-D3/3N
PLS6-D3,5/3N
PLS6-D4/3N
PLS6-D5/3N
PLS6-D6/3N
PLS6-D8/3N
PLS6-D10/3N
PLS6-D12/3N
PLS6-D13/3N
PLS6-D15/3N
PLS6-D16/3N
PLS6-D20/3N
PLS6-D25/3N
PLS6-D32/3N
PLS6-D40/3N

243025
243026
243027
243028
243029
243030
243031
243032
243033
243034
243035
243036
243037
243038
243039
243040
243041
243042
243043
243044
243045

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

2-pole
SG55411

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
3-pole
SG74311

SG73911

Explanation PLS6:
P = XPole, LS = MCB, 6 = 6 kA

129

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS6-D0,5/4
PLS6-D1/4
PLS6-D1,5/4
PLS6-D1,6/4
PLS6-D2/4
PLS6-D2,5/4
PLS6-D3/4
PLS6-D3,5/4
PLS6-D4/4
PLS6-D5/4
PLS6-D6/4
PLS6-D8/4
PLS6-D10/4
PLS6-D12/4
PLS6-D13/4
PLS6-D15/4
PLS6-D16/4
PLS6-D20/4
PLS6-D25/4
PLS6-D32/4
PLS6-D40/4

243094
243095
243096
243097
243098
243099
243100
243101
243102
243103
243104
243105
243106
243107
243108
243109
243110
243111
243112
243113
243114

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

4-pole
SG72911

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

Explanation PLS6:
P = XPole, LS = MCB, 6 = 6 kA

130

Protective Devices

Miniature Circuit Breakers PLS4, PLZ4


MW

High-quality miniature circuit breakers for residential applications


Contact position indicator red - green
Guide for secure terminal connection
3-position DIN rail clip, permits removal from existing busbar system
Comprehensive range of accessories suitable for subsequent installation
Rated currents up to 63 A
Tripping characteristics B, C
Rated breaking capacity 4.5 kA according to IEC/EN 60898-1

SG36011

131

Protective Devices
Miniature Circuit Breakers PLS4, PLZ4
4.5 kA, Characteristic B
Rated current In (A)
SG28411

Explanation PLS4:
P = XPole, LS = MCB, 4 = 4.5 kA

Type Designation

Article No.

Units per package

PLS4-B1
PLS4-B1,5
PLS4-B1,6
PLS4-B2
PLS4-B2,5
PLS4-B3
PLS4-B3,5
PLS4-B4
PLS4-B5
PLS4-B6
PLS4-B8
PLS4-B10
PLS4-B12
PLS4-B13
PLS4-B15
PLS4-B16
PLS4-B20
PLS4-B25
PLS4-B32
PLS4-B40
PLS4-B50
PLS4-B63

243141
243142
243143
243144
243145
243146
243147
243148
243149
243150
243151
243152
243153
243154
243155
243156
243157
243158
243159
243160
243161
243162

12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120

243189
243190
243191
243192
243193
243194
243195
243196
243197
243198
243199
243200
243201
243202
243203
243204
243205
243206
243207
243208
243209
243210

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

SG20711

MW

1+N-pole, 2 Module Units (MU)


PLZ4-B1/1N
1
PLZ4-B1,5/1N
1.5
PLZ4-B1,6/1N
1.6
PLZ4-B2/1N
2
PLZ4-B2,5/1N
2.5
PLZ4-B3/1N
3
PLZ4-B3,5/1N
3.5
PLZ4-B4/1N
4
PLZ4-B5/1N
5
PLZ4-B6/1N
6
PLZ4-B8/1N
8
PLZ4-B10/1N
10
PLZ4-B12/1N
12
PLZ4-B13/1N
13
PLZ4-B15/1N
15
PLZ4-B16/1N
16
PLZ4-B20/1N
20
PLZ4-B25/1N
25
PLZ4-B32/1N
32
PLZ4-B40/1N
40
PLZ4-B50/1N
50
PLZ4-B63/1N
63

132

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS4-B1/2
PLS4-B1,5/2
PLS4-B1,6/2
PLS4-B2/2
PLS4-B2,5/2
PLS4-B3/2
PLS4-B3,5/2
PLS4-B4/2
PLS4-B5/2
PLS4-B6/2
PLS4-B8/2
PLS4-B10/2
PLS4-B12/2
PLS4-B13/2
PLS4-B15/2
PLS4-B16/2
PLS4-B20/2
PLS4-B25/2
PLS4-B32/2
PLS4-B40/2
PLS4-B50/2
PLS4-B63/2

243237
243238
243239
243240
243241
243242
243243
243244
243245
243246
243247
243248
243249
243250
243251
243252
243253
243254
243255
243256
243257
243258

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PLS4-B1/3
PLS4-B1,5/3
PLS4-B1,6/3
PLS4-B2/3
PLS4-B2,5/3
PLS4-B3/3
PLS4-B3,5/3
PLS4-B4/3
PLS4-B5/3
PLS4-B6/3
PLS4-B8/3
PLS4-B10/3
PLS4-B12/3
PLS4-B13/3
PLS4-B15/3
PLS4-B16/3
PLS4-B20/3
PLS4-B25/3
PLS4-B32/3
PLS4-B40/3
PLS4-B50/3
PLS4-B63/3

243285
243286
243287
243288
243289
243290
243291
243292
243293
243294
243295
243296
243297
243298
243299
243300
243301
243302
243303
243304
243305
243306

1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40

3+N-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PLS4-B1/3N
PLS4-B1,5/3N
PLS4-B1,6/3N
PLS4-B2/3N
PLS4-B2,5/3N
PLS4-B3/3N
PLS4-B3,5/3N
PLS4-B4/3N
PLS4-B5/3N
PLS4-B6/3N
PLS4-B8/3N
PLS4-B10/3N
PLS4-B12/3N
PLS4-B13/3N
PLS4-B15/3N
PLS4-B16/3N
PLS4-B20/3N
PLS4-B25/3N
PLS4-B32/3N
PLS4-B40/3N
PLS4-B50/3N
PLS4-B63/3N

243333
243334
243335
243336
243337
243338
243339
243340
243341
243342
243343
243344
243345
243346
243347
243348
243349
243350
243351
243352
243353
243354

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

2-pole
SG22911

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63
SG31411

SG35211

Explanation PLS4:
P = XPole, LS = MCB, 4 = 4.5 kA

3-pole

133

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS4-B1/4
PLS4-B1,5/4
PLS4-B1,6/4
PLS4-B2/4
PLS4-B2,5/4
PLS4-B3/4
PLS4-B3,5/4
PLS4-B4/4
PLS4-B5/4
PLS4-B6/4
PLS4-B8/4
PLS4-B10/4
PLS4-B12/4
PLS4-B13/4
PLS4-B15/4
PLS4-B16/4
PLS4-B20/4
PLS4-B25/4
PLS4-B32/4
PLS4-B40/4
PLS4-B50/4
PLS4-B63/4

243381
243382
243383
243384
243385
243386
243387
243388
243389
243390
243391
243392
243393
243394
243395
243396
243397
243398
243399
243400
243401
243402

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

4-pole
SG37111

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Miniature Circuit Breakers PLS4, PLZ4


4.5 kA, Characteristic C
Rated current In (A)
SG28411

Type Designation

Article No.

Units per package

PLS4-C0,16
PLS4-C0,25
PLS4-C0,5
PLS4-C0,75
PLS4-C1
PLS4-C1,5
PLS4-C1,6
PLS4-C2
PLS4-C2,5
PLS4-C3
PLS4-C3,5
PLS4-C4
PLS4-C5
PLS4-C6
PLS4-C8
PLS4-C10
PLS4-C12
PLS4-C13
PLS4-C15
PLS4-C16
PLS4-C20
PLS4-C25
PLS4-C32
PLS4-C40
PLS4-C50
PLS4-C63

243163
243164
243166
243165
243167
243168
243169
243170
243171
243172
243173
243174
243175
243176
243177
243178
243179
243180
243181
243182
243183
243184
243185
243186
243187
243188

12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120

1-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLS4:
P = XPole, LS = MCB, 4 = 4.5 kA

MW

134

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLZ4-C0,16/1N
PLZ4-C0,25/1N
PLZ4-C0,5/1N
PLZ4-C0,75/1N
PLZ4-C1/1N
PLZ4-C1,5/1N
PLZ4-C1,6/1N
PLZ4-C2/1N
PLZ4-C2,5/1N
PLZ4-C3/1N
PLZ4-C3,5/1N
PLZ4-C4/1N
PLZ4-C5/1N
PLZ4-C6/1N
PLZ4-C8/1N
PLZ4-C10/1N
PLZ4-C12/1N
PLZ4-C13/1N
PLZ4-C15/1N
PLZ4-C16/1N
PLZ4-C20/1N
PLZ4-C25/1N
PLZ4-C32/1N
PLZ4-C40/1N
PLZ4-C50/1N
PLZ4-C63/1N

243211
243212
243214
243213
243215
243216
243217
243218
243219
243220
243221
243222
243223
243224
243225
243226
243227
243228
243229
243230
243231
243232
243233
243234
243235
243236

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

PLS4-C0,16/2
PLS4-C0,25/2
PLS4-C0,5/2
PLS4-C0,75/2
PLS4-C1/2
PLS4-C1,5/2
PLS4-C1,6/2
PLS4-C2/2
PLS4-C2,5/2
PLS4-C3/2
PLS4-C3,5/2
PLS4-C4/2
PLS4-C5/2
PLS4-C6/2
PLS4-C8/2
PLS4-C10/2
PLS4-C12/2
PLS4-C13/2
PLS4-C15/2
PLS4-C16/2
PLS4-C20/2
PLS4-C25/2
PLS4-C32/2
PLS4-C40/2
PLS4-C50/2
PLS4-C63/2

243259
243260
243262
243261
243263
243264
243265
243266
243267
243268
243269
243270
243271
243272
243273
243274
243275
243276
243277
243278
243279
243280
243281
243282
243283
243284

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1+N-pole, 2MU
SG20711

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63
2-pole
SG22911

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLS4:
P = XPole, LS = MCB, 4 = 4.5 kA

135

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS4-C0,16/3
PLS4-C0,25/3
PLS4-C0,5/3
PLS4-C0,75/3
PLS4-C1/3
PLS4-C1,5/3
PLS4-C1,6/3
PLS4-C2/3
PLS4-C2,5/3
PLS4-C3/3
PLS4-C3,5/3
PLS4-C4/3
PLS4-C5/3
PLS4-C6/3
PLS4-C8/3
PLS4-C10/3
PLS4-C12/3
PLS4-C13/3
PLS4-C15/3
PLS4-C16/3
PLS4-C20/3
PLS4-C25/3
PLS4-C32/3
PLS4-C40/3
PLS4-C50/3
PLS4-C63/3

243307
243308
243310
243309
243311
243312
243313
243314
243315
243316
243317
243318
243319
243320
243321
243322
243323
243324
243325
243326
243327
243328
243329
243330
243331
243332

1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40
1 / 40

PLS4-C0,16/3N
PLS4-C0,25/3N
PLS4-C0,5/3N
PLS4-C0,75/3N
PLS4-C1/3N
PLS4-C1,5/3N
PLS4-C1,6/3N
PLS4-C2/3N
PLS4-C2,5/3N
PLS4-C3/3N
PLS4-C3,5/3N
PLS4-C4/3N
PLS4-C5/3N
PLS4-C6/3N
PLS4-C8/3N
PLS4-C10/3N
PLS4-C12/3N
PLS4-C13/3N
PLS4-C15/3N
PLS4-C16/3N
PLS4-C20/3N
PLS4-C25/3N
PLS4-C32/3N
PLS4-C40/3N
PLS4-C50/3N
PLS4-C63/3N

243355
243356
243358
243357
243359
243360
243361
243362
243363
243364
243365
243366
243367
243368
243369
243370
243371
243372
243373
243374
243375
243376
243377
243378
243379
243380

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

3-pole
SG31411

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63
3+N-pole
SG35211

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLS4:
P = XPole, LS = MCB, 4 = 4.5 kA

136

Protective Devices
Rated current In (A)

Type Designation

Article No.

Units per package

PLS4-C0,16/4
PLS4-C0,25/4
PLS4-C0,5/4
PLS4-C0,75/4
PLS4-C1/4
PLS4-C1,5/4
PLS4-C1,6/4
PLS4-C2/4
PLS4-C2,5/4
PLS4-C3/4
PLS4-C3,5/4
PLS4-C4/4
PLS4-C5/4
PLS4-C6/4
PLS4-C8/4
PLS4-C10/4
PLS4-C12/4
PLS4-C13/4
PLS4-C15/4
PLS4-C16/4
PLS4-C20/4
PLS4-C25/4
PLS4-C32/4
PLS4-C40/4
PLS4-C50/4
PLS4-C63/4

243403
243404
243406
243405
243407
243408
243409
243410
243411
243412
243413
243414
243415
243416
243417
243418
243419
243420
243421
243422
243423
243424
243425
243426
243427
243428

1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30
1 / 30

4-pole
SG37111

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Explanation PLS4:
P = XPole, LS = MCB, 4 = 4.5 kA

137

Protective Devices

Miniature Circuit Breakers PLS6-DC


MW

High-quality miniature circuit breakers for DC-applications


Contact position indicator red - green
Guide for secure terminal connection
3-position DIN rail clip, permits removal from existing busbar system
Comprehensive range of accessories suitable for subsequent installation
Rated currents up to 50 A
Tripping characteristic C
Rated breaking capacity 10 kA according to IEC/EN 60947-2
Up to 250 V DC per pole

SG45311

138

Protective Devices
Miniature Circuit Breaker PLS6-DC for direct current application
10 kA, Characteristic C
Rated current In (A)
SG45311

SG55411

MW

Type Designation

Article No.

Units per package

1
2
3
4
6
10
13
16
20
25
32
40
50

PLS6-C1-DC
PLS6-C2-DC
PLS6-C3-DC
PLS6-C4-DC
PLS6-C6-DC
PLS6-C10-DC
PLS6-C13-DC
PLS6-C16-DC
PLS6-C20-DC
PLS6-C25-DC
PLS6-C32-DC
PLS6-C40-DC
PLS6-C50-DC

243115
243116
243117
243118
243119
243120
243121
243122
243123
243124
243125
243126
243127

12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120
12 / 120

2-pole
1
2
3
4
6
10
13
16
20
25
32
40
50

PLS6-C1/2-DC
PLS6-C2/2-DC
PLS6-C3/2-DC
PLS6-C4/2-DC
PLS6-C6/2-DC
PLS6-C10/2-DC
PLS6-C13/2-DC
PLS6-C16/2-DC
PLS6-C20/2-DC
PLS6-C25/2-DC
PLS6-C32/2-DC
PLS6-C40/2-DC
PLS6-C50/2-DC

243128
243129
243130
243131
243132
243133
243134
243135
243136
243137
243138
243139
243140

1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60
1 / 60

1-pole

139

Protective Devices

Miniature Circuit Breakers PL7

High-quality miniature circuit breakers for commercial and residential


applications
Contact position indicator red - green
Guide for secure terminal connection
3-position DIN rail clip, permits removal from existing busbar system
Comprehensive range of accessories suitable for subsequent installation
Rated currents up to 63 A
Tripping characteristics B, C, D
Rated breaking capacity 10 kA according to IEC/EN 60898-1

SG06511

140

Protective Devices
Miniature Circuit Breakers PL7
10 kA, Characteristic B
Rated Current In (A)
SG06211

SG06311

SG06411

Type Designation

Article No.

Units per package

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL7-B1/1
PL7-B1,5/1
PL7-B1,6/1
PL7-B2/1
PL7-B2,5/1
PL7-B3/1
PL7-B3,5/1
PL7-B4/1
PL7-B5/1
PL7-B6/1
PL7-B8/1
PL7-B10/1
PL7-B12/1
PL7-B13/1
PL7-B15/1
PL7-B16/1
PL7-B20/1
PL7-B25/1
PL7-B32/1
PL7-B40/1
PL7-B50/1
PL7-B63/1

165052
165048
165049
264839
165053
165055
165054
264850
165056
262673
165057
262674
165050
262675
165051
262676
262677
262678
262679
262690
262691
262692

12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120

1+N-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32

PL7-B1/1N
PL7-B1,5/1N
PL7-B1,6/1N
PL7-B2/1N
PL7-B2,5/1N
PL7-B3/1N
PL7-B3,5/1N
PL7-B4/1N
PL7-B5/1N
PL7-B6/1N
PL7-B8/1N
PL7-B10/1N
PL7-B12/1N
PL7-B13/1N
PL7-B15/1N
PL7-B16/1N
PL7-B20/1N
PL7-B25/1N
PL7-B32/1N

165214
165212
165213
165218
165217
165220
165219
165221
165222
262727
165223
262728
165215
262729
165216
262740
262741
262742
262743

8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80

2-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL7-B1/2
PL7-B1,5/2
PL7-B1,6/2
PL7-B2/2
PL7-B2,5/2
PL7-B3/2
PL7-B3,5/2
PL7-B4/2
PL7-B5/2
PL7-B6/2
PL7-B8/2
PL7-B10/2
PL7-B12/2
PL7-B13/2
PL7-B15/2
PL7-B16/2
PL7-B20/2
PL7-B25/2
PL7-B32/2
PL7-B40/2
PL7-B50/2
PL7-B63/2

165079
165077
165078
165083
165082
165085
165084
165086
165087
262761
165088
262762
165080
262764
165081
262765
262766
262767
262768
262769
263350
263351

6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60

1-pole

141

Protective Devices
SG06511

SG06711

SG06611

Rated Current In (A)

Type Designation

Article No.

Units per package

3-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL7-B1/3
PL7-B1,5/3
PL7-B1,6/3
PL7-B2/3
PL7-B2,5/3
PL7-B3/3
PL7-B3,5/3
PL7-B4/3
PL7-B5/3
PL7-B6/3
PL7-B8/3
PL7-B10/3
PL7-B12/3
PL7-B13/3
PL7-B15/3
PL7-B16/3
PL7-B20/3
PL7-B25/3
PL7-B32/3
PL7-B40/3
PL7-B50/3
PL7-B63/3

165112
165110
165111
165116
165115
165118
165117
116709
165119
263386
165120
263387
165113
263388
165114
263389
263390
263391
263392
263393
263400
263401

4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40

3+N-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL7-B1/3N
PL7-B1,5/3N
PL7-B1,6/3N
PL7-B2/3N
PL7-B2,5/3N
PL7-B3/3N
PL7-B3,5/3N
PL7-B4/3N
PL7-B5/3N
PL7-B6/3N
PL7-B8/3N
PL7-B10/3N
PL7-B12/3N
PL7-B13/3N
PL7-B15/3N
PL7-B16/3N
PL7-B20/3N
PL7-B25/3N
PL7-B32/3N
PL7-B40/3N
PL7-B50/3N
PL7-B63/3N

165251
165249
165250
165255
165254
165257
165256
165258
165259
263982
165260
263983
165252
263984
165253
263985
263986
263987
263988
263989
263990
263991

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

4-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL7-B1/4
PL7-B1,5/4
PL7-B1,6/4
PL7-B2/4
PL7-B2,5/4
PL7-B3/4
PL7-B3,5/4
PL7-B4/4
PL7-B5/4
PL7-B6/4
PL7-B8/4
PL7-B10/4
PL7-B12/4
PL7-B13/4
PL7-B15/4
PL7-B16/4
PL7-B20/4
PL7-B25/4
PL7-B32/4
PL7-B40/4
PL7-B50/4
PL7-B63/4

165146
165144
165145
165153
165152
165157
165156
165159
165161
165163
165165
165147
165148
165149
165150
165151
165154
165155
165158
165160
165162
165164

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

142

Protective Devices
Miniature Circuit Breakers PL7
10 kA, Characteristic C
Rated Current In (A)
SG06211

SG06311

Type Designation

Article No.

Units per package

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL7-C0,16/1
PL7-C0,25/1
PL7-C0,5/1
PL7-C0,75/1
PL7-C1/1
PL7-C1,5/1
PL7-C1,6/1
PL7-C2/1
PL7-C2,5/1
PL7-C3/1
PL7-C3,5/1
PL7-C4/1
PL7-C5/1
PL7-C6/1
PL7-C8/1
PL7-C10/1
PL7-C12/1
PL7-C13/1
PL7-C15/1
PL7-C16/1
PL7-C20/1
PL7-C25/1
PL7-C32/1
PL7-C40/1
PL7-C50/1
PL7-C63/1

262693
262694
262695
262696
262697
165058
262698
262699
165061
165063
165062
262700
165064
262701
165065
262702
165059
262703
165060
262704
262705
262706
262707
262708
262709
262710

12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120

1+N-pole
0.16
0.25
0.5
0.75
1
1,5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32

PL7-C0,16/1N
PL7-C0,25/1N
PL7-C0,5/1N
PL7-C0,75/1N
PL7-C1/1N
PL7-C1,5/1N
PL7-C1,6/1N
PL7-C2/1N
PL7-C2,5/1N
PL7-C3/1N
PL7-C3,5/1N
PL7-C4/1N
PL7-C5/1N
PL7-C6/1N
PL7-C8/1N
PL7-C10/1N
PL7-C12/1N
PL7-C13/1N
PL7-C15/1N
PL7-C16/1N
PL7-C20/1N
PL7-C25/1N
PL7-C32/1N

165224
165225
165226
165227
165230
165228
165229
262744
165233
165235
165234
262745
165236
262746
165237
262747
165231
262748
165232
262749
262750
262751
262752

8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80

1-pole

143

Protective Devices
SG06411

SG06511

Rated Current In (A)

Type Designation

Article No.

Units per package

2-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL7-C0,16/2
PL7-C0,25/2
PL7-C0,5/2
PL7-C0,75/2
PL7-C1/2
PL7-C1,5/2
PL7-C1,6/2
PL7-C2/2
PL7-C2,5/2
PL7-C3/2
PL7-C3,5/2
PL7-C4/2
PL7-C5/2
PL7-C6/2
PL7-C8/2
PL7-C10/2
PL7-C12/2
PL7-C13/2
PL7-C15/2
PL7-C16/2
PL7-C20/2
PL7-C25/2
PL7-C32/2
PL7-C40/2
PL7-C50/2
PL7-C63/2

165089
165090
263352
165091
263353
165092
165093
263354
165096
165098
165097
263355
165099
263356
165100
263357
165094
263358
165095
263359
263360
263361
263362
263363
263364
263365

6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60

PL7-C0,16/3
PL7-C0,25/3
PL7-C0,5/3
PL7-C0,75/3
PL7-C1/3
PL7-C1,5/3
PL7-C1,6/3
PL7-C2/3
PL7-C2,5/3
PL7-C3/3
PL7-C3,5/3
PL7-C4/3
PL7-C5/3
PL7-C6/3
PL7-C8/3
PL7-C10/3
PL7-C12/3
PL7-C13/3
PL7-C15/3
PL7-C16/3
PL7-C20/3
PL7-C25/3
PL7-C32/3
PL7-C40/3
PL7-C50/3
PL7-C63/3

165121
165122
263402
165123
263403
165124
165125
263404
165128
165130
165129
263405
165131
263406
165132
263407
165126
263408
165127
263409
263410
263411
263412
263413
263414
263415

4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40

3-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

144

Protective Devices
SG06711

SG06611

Rated Current In (A)

Type Designation

Article No.

Units per package

3+N-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL7-C0,16/3N
PL7-C0,25/3N
PL7-C0,5/3N
PL7-C0,75/3N
PL7-C1/3N
PL7-C1,5/3N
PL7-C1,6/3N
PL7-C2/3N
PL7-C2,5/3N
PL7-C3/3N
PL7-C3,5/3N
PL7-C4/3N
PL7-C5/3N
PL7-C6/3N
PL7-C8/3N
PL7-C10/3N
PL7-C12/3N
PL7-C13/3N
PL7-C15/3N
PL7-C16/3N
PL7-C20/3N
PL7-C25/3N
PL7-C32/3N
PL7-C40/3N
PL7-C50/3N
PL7-C63/3N

165261
165262
165263
165264
165267
165265
165266
165271
165270
165273
165272
165274
165275
263992
165276
263993
165268
263994
165269
263995
263996
263997
263998
263999
264000
264001

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

PL7-C0,16/4
PL7-C0,25/4
PL7-C0,5/4
PL7-C0,75/4
PL7-C1/4
PL7-C1,5/4
PL7-C1,6/4
PL7-C2/4
PL7-C2,5/4
PL7-C3/4
PL7-C3,5/4
PL7-C4/4
PL7-C5/4
PL7-C6/4
PL7-C8/4
PL7-C10/4
PL7-C12/4
PL7-C13/4
PL7-C15/4
PL7-C16/4
PL7-C20/4
PL7-C25/4
PL7-C32/4
PL7-C40/4
PL7-C50/4
PL7-C63/4

165166
165167
165168
165169
165172
165170
165171
165178
165177
165182
165181
165184
165186
165188
165190
165173
165174
165175
165176
107329
165179
165180
165183
165185
165187
165189

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

4-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

145

Protective Devices
Miniature Circuit Breakers PL7
10 kA, Characteristic D
Rated Current In (A)
SG06211

SG06311

SG06411

Type Designation

Article No.

Units per package

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL7-D0,5/1
PL7-D1/1
PL7-D1,5/1
PL7-D1,6/1
PL7-D2/1
PL7-D2,5/1
PL7-D3/1
PL7-D3,5/1
PL7-D4/1
PL7-D5/1
PL7-D6/1
PL7-D8/1
PL7-D10/1
PL7-D12/1
PL7-D13/1
PL7-D15/1
PL7-D16/1
PL7-D20/1
PL7-D25/1
PL7-D32/1
PL7-D40/1

165066
165071
165067
165068
262711
165072
165074
165073
262712
165075
262713
165076
262714
165069
262715
165070
262716
262717
262718
262719
262720

12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120

1+N-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25

PL7-D0,5/1N
PL7-D1/1N
PL7-D1,5/1N
PL7-D1,6/1N
PL7-D2/1N
PL7-D2,5/1N
PL7-D3/1N
PL7-D3,5/1N
PL7-D4/1N
PL7-D5/1N
PL7-D6/1N
PL7-D8/1N
PL7-D10/1N
PL7-D12/1N
PL7-D13/1N
PL7-D15/1N
PL7-D16/1N
PL7-D20/1N
PL7-D25/1N

165238
165241
165239
165240
262753
165244
165246
165245
262754
165247
262755
165248
262756
165242
262757
165243
262758
262759
262760

8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80

2-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL7-D0,5/2
PL7-D1/2
PL7-D1,5/2
PL7-D1,6/2
PL7-D2/2
PL7-D2,5/2
PL7-D3/2
PL7-D3,5/2
PL7-D4/2
PL7-D5/2
PL7-D6/2
PL7-D8/2
PL7-D10/2
PL7-D12/2
PL7-D13/2
PL7-D15/2
PL7-D16/2
PL7-D20/2
PL7-D25/2
PL7-D32/2
PL7-D40/2

165101
108184
165102
165103
263366
165106
108185
165107
263367
165108
263368
165109
263369
165104
263380
165105
263381
263382
263383
263384
263385

6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60

1-pole

146

Protective Devices
Rated Current In (A)

Type Designation

Article No.

Units per package

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL7-D0,5/3
PL7-D1/3
PL7-D1,5/3
PL7-D1,6/3
PL7-D2/3
PL7-D2,5/3
PL7-D3/3
PL7-D3,5/3
PL7-D4/3
PL7-D5/3
PL7-D6/3
PL7-D8/3
PL7-D10/3
PL7-D12/3
PL7-D13/3
PL7-D15/3
PL7-D16/3
PL7-D20/3
PL7-D25/3
PL7-D32/3
PL7-D40/3

165133
165136
165134
165135
263416
165139
165141
165140
263417
165142
263418
165143
263419
165137
263420
165138
263421
263422
263423
263424
263425

4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40

3+N-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL7-D0,5/3N
PL7-D1/3N
PL7-D1,5/3N
PL7-D1,6/3N
PL7-D2/3N
PL7-D2,5/3N
PL7-D3/3N
PL7-D3,5/3N
PL7-D4/3N
PL7-D5/3N
PL7-D6/3N
PL7-D8/3N
PL7-D10/3N
PL7-D12/3N
PL7-D13/3N
PL7-D15/3N
PL7-D16/3N
PL7-D20/3N
PL7-D25/3N
PL7-D32/3N
PL7-D40/3N

165277
165280
165278
165279
165284
165283
165286
165285
165287
165288
264002
165289
264003
165281
264004
165282
264005
264006
264007
264008
264009

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

4-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL7-D0,5/4
PL7-D1/4
PL7-D1,5/4
PL7-D1,6/4
PL7-D2/4
PL7-D2,5/4
PL7-D3/4
PL7-D3,5/4
PL7-D4/4
PL7-D5/4
PL7-D6/4
PL7-D8/4
PL7-D10/4
PL7-D12/4
PL7-D13/4
PL7-D15/4
PL7-D16/4
PL7-D20/4
PL7-D25/4
PL7-D32/4
PL7-D40/4

165191
165194
165192
165193
165201
165200
165205
165204
165207
165209
165210
165211
165195
165196
165197
165198
165199
165202
165203
165206
165208

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

3-pole
SG06511

SG06711

SG06611

147

Protective Devices

Miniature Circuit Breakers PL6

High-quality miniature circuit breakers for commercial and residential


applications
Contact position indicator red - green
Guide for secure terminal connection
3-position DIN rail clip, permits removal from existing busbar system
Comprehensive range of accessories suitable for subsequent installation
Rated currents up to 63 A
Tripping characteristics B, C, D
Rated breaking capacity 6 kA according to IEC/EN 60898-1

SG62211

148

Protective Devices
Miniature Circuit Breakers PL6
6 kA, Characteristic B
Rated Current In (A)
SG45411

SG51411

SG51511

Type Designation

Article No.

Units per package

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-B1/1
PL6-B1,5/1
PL6-B1,6/1
PL6-B2/1
PL6-B2,5/1
PL6-B3/1
PL6-B3,5/1
PL6-B4/1
PL6-B5/1
PL6-B6/1
PL6-B8/1
PL6-B10/1
PL6-B12/1
PL6-B13/1
PL6-B15/1
PL6-B16/1
PL6-B20/1
PL6-B25/1
PL6-B32/1
PL6-B40/1
PL6-B50/1
PL6-B63/1

164740
164736
164737
286516
164741
164743
164742
286517
164744
286518
164745
286519
164738
286520
164739
286521
286522
286523
286524
286525
286526
286527

12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120

1+N-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32

PL6-B1/1N
PL6-B1,5/1N
PL6-B1,6/1N
PL6-B2/1N
PL6-B2,5/1N
PL6-B3/1N
PL6-B3,5/1N
PL6-B4/1N
PL6-B5/1N
PL6-B6/1N
PL6-B8/1N
PL6-B10/1N
PL6-B12/1N
PL6-B13/1N
PL6-B15/1N
PL6-B16/1N
PL6-B20/1N
PL6-B25/1N
PL6-B32/1N

164903
164901
164902
164907
164906
164911
164910
164913
164914
106025
164915
106026
164904
106027
164905
106028
164908
164909
164912

8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80

2-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-B1/2
PL6-B1,5/2
PL6-B1,6/2
PL6-B2/2
PL6-B2,5/2
PL6-B3/2
PL6-B3,5/2
PL6-B4/2
PL6-B5/2
PL6-B6/2
PL6-B8/2
PL6-B10/2
PL6-B12/2
PL6-B13/2
PL6-B15/2
PL6-B16/2
PL6-B20/2
PL6-B25/2
PL6-B32/2
PL6-B40/2
PL6-B50/2
PL6-B63/2

164803
164801
164802
286550
164806
164808
164807
286551
164809
286552
164810
286553
164804
286554
164805
286555
286556
286557
286558
286559
286560
286561

6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60

1-pole

149

Protective Devices
Rated Current In (A)

Type Designation

Article No.

Units per package

1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-B1/3
PL6-B1,5/3
PL6-B1,6/3
PL6-B2/3
PL6-B2,5/3
PL6-B3/3
PL6-B3,5/3
PL6-B4/3
PL6-B5/3
PL6-B6/3
PL6-B8/3
PL6-B10/3
PL6-B12/3
PL6-B13/3
PL6-B15/3
PL6-B16/3
PL6-B20/3
PL6-B25/3
PL6-B32/3
PL6-B40/3
PL6-B50/3
PL6-B63/3

164868
164866
164867
286584
164871
164873
164872
286585
164874
286586
164875
286587
164869
286588
164870
286589
286590
286591
286592
286593
286594
286595

4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40

3+N-pole
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-B1/3N
PL6-B1,5/3N
PL6-B1,6/3N
PL6-B2/3N
PL6-B2,5/3N
PL6-B3/3N
PL6-B3,5/3N
PL6-B4/3N
PL6-B5/3N
PL6-B6/3N
PL6-B8/3N
PL6-B10/3N
PL6-B12/3N
PL6-B13/3N
PL6-B15/3N
PL6-B16/3N
PL6-B20/3N
PL6-B25/3N
PL6-B32/3N
PL6-B40/3N
PL6-B50/3N
PL6-B63/3N

165002
165000
165001
165007
165006
165009
165008
165010
165011
106035
165012
106036
165003
165004
165005
106037
106038
106039
106040
106041
106903
106904

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

4-pole
1
1.5
1.6
2
2.5
3
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-B1/4
PL6-B1,5/4
PL6-B1,6/4
PL6-B2/4
PL6-B2,5/4
PL6-B3/4
PL6-B4/4
PL6-B5/4
PL6-B6/4
PL6-B8/4
PL6-B10/4
PL6-B12/4
PL6-B13/4
PL6-B15/4
PL6-B16/4
PL6-B20/4
PL6-B25/4
PL6-B32/4
PL6-B40/4
PL6-B50/4
PL6-B63/4

166489
166487
166488
166496
166495
166499
166501
166503
166505
166507
166490
166491
166492
166493
166494
166497
166498
166500
166502
166504
166506

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

3-pole
SG62211

SG64711

150

Protective Devices
Miniature Circuit Breakers PL6
6 kA, Characteristic C
Rated Current In (A)
SG45411

SG51411

Type Designation

Article No.

Units per package

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-C0,16/1
PL6-C0,25/1
PL6-C0,5/1
PL6-C0,75/1
PL6-C1/1
PL6-C1,5/1
PL6-C1,6/1
PL6-C2/1
PL6-C2,5/1
PL6-C3/1
PL6-C3,5/1
PL6-C4/1
PL6-C5/1
PL6-C6/1
PL6-C8/1
PL6-C10/1
PL6-C12/1
PL6-C13/1
PL6-C15/1
PL6-C16/1
PL6-C20/1
PL6-C25/1
PL6-C32/1
PL6-C40/1
PL6-C50/1
PL6-C63/1

164746
164747
164748
164749
164754
164750
164751
286528
164755
164757
164756
286529
164758
286530
164759
286531
164752
286532
164753
286533
286534
286535
286536
286537
286538
286539

12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120

1+N-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32

PL6-C0,16/1N
PL6-C0,25/1N
PL6-C0,5/1N
PL6-C0,75/1N
PL6-C1/1N
PL6-C1,5/1N
PL6-C1,6/1N
PL6-C2/1N
PL6-C2,5/1N
PL6-C3/1N
PL6-C3,5/1N
PL6-C4/1N
PL6-C5/1N
PL6-C6/1N
PL6-C8/1N
PL6-C10/1N
PL6-C12/1N
PL6-C13/1N
PL6-C15/1N
PL6-C16/1N
PL6-C20/1N
PL6-C25/1N
PL6-C32/1N

164916
164917
164918
164919
164922
164920
164921
106029
164925
164929
164928
106030
164931
106031
164932
106032
164923
106033
164924
106034
164926
164927
164930

8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80

1-pole

151

Protective Devices
Rated Current In (A)

Type Designation

Article No.

Units per package

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-C0,16/2
PL6-C0,25/2
PL6-C0,5/2
PL6-C0,75/2
PL6-C1/2
PL6-C1,5/2
PL6-C1,6/2
PL6-C2/2
PL6-C2,5/2
PL6-C3/2
PL6-C3,5/2
PL6-C4/2
PL6-C5/2
PL6-C6/2
PL6-C8/2
PL6-C10/2
PL6-C12/2
PL6-C13/2
PL6-C15/2
PL6-C16/2
PL6-C20/2
PL6-C25/2
PL6-C32/2
PL6-C40/2
PL6-C50/2
PL6-C63/2

164811
164812
164813
164814
164817
164815
164816
286562
164820
164822
164821
286563
164823
286564
164824
286565
164818
286566
164819
286567
286568
286569
286570
286571
286572
286573

6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60

3-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-C0,16/3
PL6-C0,25/3
PL6-C0,5/3
PL6-C0,75/3
PL6-C1/3
PL6-C1,5/3
PL6-C1,6/3
PL6-C2/3
PL6-C2,5/3
PL6-C3/3
PL6-C3,5/3
PL6-C4/3
PL6-C5/3
PL6-C6/3
PL6-C8/3
PL6-C10/3
PL6-C12/3
PL6-C13/3
PL6-C15/3
PL6-C16/3
PL6-C20/3
PL6-C25/3
PL6-C32/3
PL6-C40/3
PL6-C50/3
PL6-C63/3

164876
164877
164878
164879
164882
164880
164881
286596
164885
164887
164886
286597
164888
286598
164889
286599
164883
286600
164884
286601
286602
286603
286604
286605
286606
286607

4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40

2-pole
SG51511

SG62211

152

Protective Devices
Rated Current In (A)

Type Designation

Article No.

Units per package

0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-C0,16/3N
PL6-C0,25/3N
PL6-C0,5/3N
PL6-C0,75/3N
PL6-C1/3N
PL6-C1,5/3N
PL6-C1,6/3N
PL6-C2/3N
PL6-C2,5/3N
PL6-C3/3N
PL6-C3,5/3N
PL6-C4/3N
PL6-C5/3N
PL6-C6/3N
PL6-C8/3N
PL6-C10/3N
PL6-C12/3N
PL6-C13/3N
PL6-C15/3N
PL6-C16/3N
PL6-C20/3N
PL6-C25/3N
PL6-C32/3N
PL6-C40/3N
PL6-C50/3N
PL6-C63/3N

165013
165014
165015
165016
165019
165017
165018
106905
165022
165024
165023
106906
165025
106907
165026
106908
165020
106909
165021
106910
106911
106912
106913
106914
106915
106916

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

4-pole
0.16
0.25
0.5
0.75
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL6-C0,16/4
PL6-C0,25/4
PL6-C0,5/4
PL6-C0,75/4
PL6-C1/4
PL6-C1,5/4
PL6-C1,6/4
PL6-C2/4
PL6-C2,5/4
PL6-C3/4
PL6-C3,5/4
PL6-C4/4
PL6-C5/4
PL6-C6/4
PL6-C8/4
PL6-C10/4
PL6-C12/4
PL6-C13/4
PL6-C15/4
PL6-C16/4
PL6-C20/4
PL6-C25/4
PL6-C32/4
PL6-C40/4
PL6-C50/4
PL6-C63/4

166508
166509
166510
166511
166514
166512
166513
166521
166520
166525
166524
166527
166529
166531
166533
166515
166516
166517
166518
166519
166522
166523
166526
166528
166530
166532

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

3+N-pole
SG64711

153

Protective Devices
Miniature Circuit Breakers PL6
6 kA, Characteristic D
Rated Current In (A)
SG45411

SG51411

SG51511

Type Designation

Article No.

Units per package

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL6-D0,5/1
PL6-D1/1
PL6-D1,5/1
PL6-D1,6/1
PL6-D2/1
PL6-D2,5/1
PL6-D3/1
PL6-D3,5/1
PL6-D4/1
PL6-D5/1
PL6-D6/1
PL6-D8/1
PL6-D10/1
PL6-D12/1
PL6-D13/1
PL6-D15/1
PL6-D16/1
PL6-D20/1
PL6-D25/1
PL6-D32/1
PL6-D40/1

164760
164765
164761
164762
286540
164766
164768
164767
286541
164769
286542
164770
286543
164763
286544
164764
286545
286546
286547
286548
286549

12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120

1+N-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25

PL6-D0,5/1N
PL6-D1/1N
PL6-D1,5/1N
PL6-D1,6/1N
PL6-D2/1N
PL6-D2,5/1N
PL6-D3/1N
PL6-D3,5/1N
PL6-D4/1N
PL6-D5/1N
PL6-D6/1N
PL6-D8/1N
PL6-D10/1N
PL6-D12/1N
PL6-D13/1N
PL6-D15/1N
PL6-D16/1N
PL6-D20/1N
PL6-D25/1N

164933
164936
164934
164935
164943
164942
164947
164946
164948
164949
164950
164951
164937
164938
164939
164940
164941
164944
164945

8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80

2-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL6-D0,5/2
PL6-D1/2
PL6-D1,5/2
PL6-D1,6/2
PL6-D2/2
PL6-D2,5/2
PL6-D3/2
PL6-D3,5/2
PL6-D4/2
PL6-D5/2
PL6-D6/2
PL6-D8/2
PL6-D10/2
PL6-D12/2
PL6-D13/2
PL6-D15/2
PL6-D16/2
PL6-D20/2
PL6-D25/2
PL6-D32/2
PL6-D40/2

164825
164828
164826
164827
286574
164831
164833
164832
286575
164834
286576
164835
286577
164829
286578
164830
286579
286580
286581
286582
286583

6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60

1-pole

154

Protective Devices
Rated Current In (A)

Type Designation

Article No.

Units per package

0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL6-D0,5/3
PL6-D1/3
PL6-D1,5/3
PL6-D1,6/3
PL6-D2/3
PL6-D2,5/3
PL6-D3/3
PL6-D3,5/3
PL6-D4/3
PL6-D5/3
PL6-D6/3
PL6-D8/3
PL6-D10/3
PL6-D12/3
PL6-D13/3
PL6-D15/3
PL6-D16/3
PL6-D20/3
PL6-D25/3
PL6-D32/3
PL6-D40/3

164890
164893
164891
164892
286608
164896
164898
164897
286609
164899
286610
164900
286611
164894
286612
164895
286613
286614
286615
286616
286617

4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40

3+N-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL6-B0,5/3N
PL6-B1/3N
PL6-B1,5/3N
PL6-B1,6/3N
PL6-B2/3N
PL6-B2,5/3N
PL6-B3/3N
PL6-B3,5/3N
PL6-B4/3N
PL6-B5/3N
PL6-B6/3N
PL6-B8/3N
PL6-B10/3N
PL6-B12/3N
PL6-B13/3N
PL6-B15/3N
PL6-B16/3N
PL6-B20/3N
PL6-B25/3N
PL6-B32/3N
PL6-B40/3N

165027
165030
165028
165029
165037
165036
165041
165040
165043
165045
165046
165047
165031
165032
165033
165034
165035
165038
165039
165042
165044

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

4-pole
0.5
1
1.5
1.6
2
2.5
3
3.5
4
5
6
8
10
12
13
15
16
20
25
32
40

PL6-B0,5/4
PL6-B1/4
PL6-B1,5/4
PL6-B1,6/4
PL6-B2/4
PL6-B2,5/4
PL6-B3/4
PL6-B3,5/4
PL6-B4/4
PL6-B5/4
PL6-B6/4
PL6-B8/4
PL6-B10/4
PL6-B12/4
PL6-B13/4
PL6-B15/4
PL6-B16/4
PL6-B20/4
PL6-B25/4
PL6-B32/4
PL6-B40/4

166534
166537
166535
166536
166544
166543
166548
166547
166550
166552
166553
166554
166538
166539
166540
166541
166542
166545
166546
166549
166551

3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30
3/30

3-pole
SG62211

SG64711

155

Protective Devices

Miniature Circuit Breakers PL7-DC

High-quality miniature circuit breakers for DC-applications


Contact position indicator red - green
Guide for secure terminal connection
3-position DIN rail clip, permits removal from existing busbar system
Comprehensive range of accessories suitable for subsequent installation
Rated currents up to 50 A
Tripping characteristic C
Rated breaking capacity 10 kA according to IEC/EN 60947-2
Up to 250 V DC per pole

SG06211

156

Protective Devices
Miniature Circuit Breakers PL7-DC for AC/DC
10 kA, Characteristic C
Rated Current In (A)
SG06211

SG06411

Type Designation

Article No.

Units per package

1
2
3
4
6
10
13
16
20
25
32
40
50

PL7-C1/1-DC
PL7-C2/1-DC
PL7-C3/1-DC
PL7-C4/1-DC
PL7-C6/1-DC
PL7-C10/1-DC
PL7-C13/1-DC
PL7-C16/1-DC
PL7-C20/1-DC
PL7-C25/1-DC
PL7-C32/1-DC
PL7-C40/1-DC
PL7-C50/1-DC

264851
264883
264884
264885
264886
264887
264888
264889
264890
264891
264892
264893
264894

12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120

2-pole
1
2
3
4
6
10
13
16
20
25
32
40
50

PL7-C1/2-DC
PL7-C2/2-DC
PL7-C3/2-DC
PL7-C4/2-DC
PL7-C6/2-DC
PL7-C10/2-DC
PL7-C13/2-DC
PL7-C16/2-DC
PL7-C20/2-DC
PL7-C25/2-DC
PL7-C32/2-DC
PL7-C40/2-DC
PL7-C50/2-DC

264895
264896
264897
264898
264899
264900
264901
264902
264903
264904
264905
264906
264907

6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60

1-pole

157

Protective Devices

Miniature Circuit Breakers PL4

High-quality miniature circuit breakers for commercial and residential


applications
Contact position indicator red - green
Guide for secure terminal connection
3-position DIN rail clip, permits removal from existing busbar system
Comprehensive range of accessories suitable for subsequent installation
Rated currents up to 63 A
Tripping characteristics B, C
Rated breaking capacity 4.5 kA according to IEC/EN 60898-1

SG62211

158

Protective Devices
Miniature Circuit Breakers PL4
4.5 kA, Characteristic B
Rated Current In (A)
SG45411

SG51511

Type Designation

Article No.

Units per package

1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL4-B1/1
PL4-B1,5/1
PL4-B1,6/1
PL4-B2/1
PL4-B2,5/1
PL4-B3/1
PL4-B3,5/1
PL4-B4/1
PL4-B5/1
PL4-B6/1
PL4-B8/1
PL4-B10/1
PL4-B12/1
PL4-B13/1
PL4-B15/1
PL4-B16/1
PL4-B20/1
PL4-B25/1
PL4-B32/1
PL4-B40/1
PL4-B50/1
PL4-B63/1

164711
164706
164707
164713
164712
164715
164714
164716
164717
293113
164718
293114
164708
164709
164710
293115
293116
293117
293118
293119
293120
293121

12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120

2-pole
1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL4-B1/2
PL4-B1,5/2
PL4-B1,6/2
PL4-B2/2
PL4-B2,5/2
PL4-B3/2
PL4-B3,5/2
PL4-B4/2
PL4-B5/2
PL4-B6/2
PL4-B8/2
PL4-B10/2
PL4-B12/2
PL4-B13/2
PL4-B15/2
PL4-B16/2
PL4-B20/2
PL4-B25/2
PL4-B32/2
PL4-B40/2
PL4-B50/2
PL4-B63/2

164773
164771
164772
164778
164777
164780
164779
164781
164782
293131
164783
293132
164774
164775
164776
293133
293134
293135
293136
293137
293138
293139

6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60

1-pole

159

Protective Devices
Rated Current In (A)

Type Designation

Article No.

Units per package

1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL4-B1/3
PL4-B1,5/3
PL4-B1,6/3
PL4-B2/3
PL4-B2,5/3
PL4-B3/3
PL4-B3,5/3
PL4-B4/3
PL4-B5/3
PL4-B6/3
PL4-B8/3
PL4-B10/3
PL4-B12/3
PL4-B13/3
PL4-B15/3
PL4-B16/3
PL4-B20/3
PL4-B25/3
PL4-B32/3
PL4-B40/3
PL4-B50/3
PL4-B63/3

164838
164836
164837
164843
164842
164845
164844
164846
164847
293149
164848
293150
164839
164840
164841
293151
293152
293153
293154
293155
293156
293157

4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40

3+N-pole
1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL4-B1/3N
PL4-B1,5/3N
PL4-B1,6/3N
PL4-B2/3N
PL4-B2,5/3N
PL4-B3/3N
PL4-B3,5/3N
PL4-B4/3N
PL4-B5/3N
PL4-B6/3N
PL4-B8/3N
PL4-B10/3N
PL4-B12/3N
PL4-B13/3N
PL4-B15/3N
PL4-B16/3N
PL4-B20/3N
PL4-B25/3N
PL4-B32/3N
PL4-B40/3N
PL4-B50/3N
PL4-B63/3N

164954
164952
164953
164961
164960
164965
164964
164967
164969
164971
164973
164955
164956
164957
164958
164959
164962
164963
164966
164968
164970
164972

1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30

3-pole
SG62211

SG64711

160

Protective Devices
Rated Current In (A)

Type Designation

Article No.

Units per package

PL4-B1/4
PL4-B1,5/4
PL4-B1,6/4
PL4-B2/4
PL4-B2,5/4
PL4-B3/4
PL4-B3,5/4
PL4-B4/4
PL4-B5/4
PL4-B6/4
PL4-B8/4
PL4-B10/4
PL4-B12/4
PL4-B13/4
PL4-B15/4
PL4-B16/4
PL4-B20/4
PL4-B25/4
PL4-B32/4
PL4-B40/4
PL4-B50/4
PL4-B63/4

166441
166439
166440
166448
166447
166452
166451
166454
166456
166458
166460
166442
166443
166444
166445
166446
166449
166450
166453
166455
166457
166459

1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30

Type Designation

Article No.

Units per package

PL4-C0,16/1
PL4-C0,25/1
PL4-C0,5/1
PL4-C0,75/1
PL4-C1/1
PL4-C1,5/1
PL4-C1,6/1
PL4-C2/1
PL4-C2,5/1
PL4-C3/1
PL4-C3,5/1
PL4-C4/1
PL4-C5/1
PL4-C6/1
PL4-C8/1
PL4-C10/1
PL4-C12/1
PL4-C13/1
PL4-C15/1
PL4-C16/1
PL4-C20/1
PL4-C25/1
PL4-C32/1
PL4-C40/1
PL4-C50/1
PL4-C63/1

164719
164720
164721
164722
164728
164723
164724
164730
164729
164732
164731
164733
164734
293122
164735
293123
164725
164726
164727
293124
293125
293126
293127
293128
293129
293130

12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120
12/120

4-pole
1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

Miniature Circuit Breakers PL4


4.5 kA, Characteristic C
Rated Current In (A)
SG45411

1-pole
0,16
0,25
0,5
0,75
1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

161

Protective Devices
Rated Current In (A)
SG51511

SG62211

Type Designation

Article No.

Units per package

0,16
0,25
0,5
0,75
1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL4-C0,16/2
PL4-C0,25/2
PL4-C0,5/2
PL4-C0,75/2
PL4-C1/2
PL4-C1,5/2
PL4-C1,6/2
PL4-C2/2
PL4-C2,5/2
PL4-C3/2
PL4-C3,5/2
PL4-C4/2
PL4-C5/2
PL4-C6/2
PL4-C8/2
PL4-C10/2
PL4-C12/2
PL4-C13/2
PL4-C15/2
PL4-C16/2
PL4-C20/2
PL4-C25/2
PL4-C32/2
PL4-C40/2
PL4-C50/2
PL4-C63/2

164784
164785
164786
164787
164790
164788
164789
164795
164794
164797
164796
164798
164799
293140
164800
293141
164791
164792
164793
293142
293143
293144
293145
293146
293147
293148

6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60
6/60

3-pole
0,16
0,25
0,5
0,75
1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL4-C0,16/3
PL4-C0,25/3
PL4-C0,5/3
PL4-C0,75/3
PL4-C1/3
PL4-C1,5/3
PL4-C1,6/3
PL4-C2/3
PL4-C2,5/3
PL4-C3/3
PL4-C3,5/3
PL4-C4/3
PL4-C5/3
PL4-C6/3
PL4-C8/3
PL4-C10/3
PL4-C12/3
PL4-C13/3
PL4-C15/3
PL4-C16/3
PL4-C20/3
PL4-C25/3
PL4-C32/3
PL4-C40/3
PL4-C50/3
PL4-C63/3

164849
164850
164851
164852
164855
164853
164854
164860
164859
164862
164861
164863
164864
293158
164865
293159
164856
164857
164858
293160
293161
293162
293163
293164
293165
293166

4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40
4/40

2-pole

162

Protective Devices
Rated Current In (A)
SG64711

Type Designation

Article No.

Units per package

0,16
0,25
0,5
0,75
1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL4-C0,16/3N
PL4-C0,25/3N
PL4-C0,5/3N
PL4-C0,75/3N
PL4-C1/3N
PL4-C1,5/3N
PL4-C1,6/3N
PL4-C2/3N
PL4-C2,5/3N
PL4-C3/3N
PL4-C3,5/3N
PL4-C4/3N
PL4-C5/3N
PL4-C6/3N
PL4-C8/3N
PL4-C10/3N
PL4-C12/3N
PL4-C13/3N
PL4-C15/3N
PL4-C16/3N
PL4-C20/3N
PL4-C25/3N
PL4-C32/3N
PL4-C40/3N
PL4-C50/3N
PL4-C63/3N

164974
164975
164976
164977
164980
164978
164979
164987
164986
164991
164990
164993
164995
164997
164999
164981
164982
164983
164984
164985
164988
164989
164992
164994
164996
164998

1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30

4-pole
0,16
0,25
0,5
0,75
1
1,5
1,6
2
2,5
3
3,5
4
5
6
8
10
12
13
15
16
20
25
32
40
50
63

PL4-C0,16/4
PL4-C0,25/4
PL4-C0,5/4
PL4-C0,75/4
PL4-C1/4
PL4-C1,5/4
PL4-C1,6/4
PL4-C2/4
PL4-C2,5/4
PL4-C3/4
PL4-C3,5/4
PL4-C4/4
PL4-C5/4
PL4-C6/4
PL4-C8/4
PL4-C10/4
PL4-C12/4
PL4-C13/4
PL4-C15/4
PL4-C16/4
PL4-C20/4
PL4-C25/4
PL4-C32/4
PL4-C40/4
PL4-C50/4
PL4-C63/4

166461
166462
166463
166464
166467
166465
166466
166474
166473
166478
166477
166480
166482
166484
166486
166468
166469
166470
166471
166472
166475
166476
166479
166481
166483
166485

1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30

3+N-pole

163

Protective Devices
Miniature Circuit Breakers PLS..., PLZ...
High selectivity between MCB and back-up fuse due to low let-through
energy
Compatible with standard busbar
Twin-purpose terminal (lift/open-mouthed) above and below
Busbar positioning optionally above or below
Meets the requirements of insulation co-ordination,
distance between contacts 4 mm, for secure isolation
Suitable for applications up to 48 V DC (use PLS6-DC for higher DC voltages)

Accessories:
Auxiliary switch for
subsequent installation
Tripping signal contact for
subsequent installation
Remote control and automatic switching device
Shunt trip release
Undervoltage release
Compact enclosure
Additional terminal 35mm2
Switching interlock

ZP-IHK

286052

ZP-NHK
Z-FW/LP
ZP-ASA/..
Z-USA/..
KLV-TC-2
KLV-TC-4
Z-HA-EK/35
Z-IS/SPE-1TE

248437
248296
248438, 248439
248288-248291
276240
276241
263960
274418

Connection diagrams
1-pole

1+N-pole (1.5MU)

1+N-pole (2MU)

3-pole

3+N-pole

4-pole

2-pole

Technical Data
Electrical
Design according to
IEC/EN 60898-1
Current test marks as printed onto the device
Rated voltage
AC: 230/400V
DC: 48V (per pole,
max. 2 poles)
Rated frequency
50/60 Hz
Rated breaking capacity according to IEC/EN 60898-1
PLSM, PLZM
10 kA
PLS6, PLZ6
6 kA
PLS4, PLZ4
4.5 kA
Characteristic
B, C, D
Back-up fuse
PLSM
max. 125 A gL
PLS6
max. 100 A gL
PLS4
max. 80 A gL
Selectivity class
3
Rated peak withstand voltage Uimp
4 kV (1.2/50s)
Endurance
electrical comp.
4,000 operating cycles
mechanical comp.
20,000 operating cycles
Line voltage connection
optional (above/below)

Mechanical
Frame size
Device height
Device width
Mounting

Degree of protection
Upper and lower terminals
Terminal protection
Terminal capacity
(1p+N, 1.5MU)
Terminal fastening torque
(1p+N, 1.5MU)
Busbar thickness
Mounting

Dimensions (mm)

66

45 mm
80 mm
17.5 mm per pole (1MU)
26.3 mm: device 1P+N (1.5MU)
quick fastening with
3 lock-in positions on
DIN rail IEC/EN 60715
IP20
open mouthed/lift terminals
finger and hand touch safe,
BGV A3, VE-EN 6
1-25 mm2
1-25 mm2 / 1-2x10 mm2 (N)
2-2.4 Nm
2-2.4 Nm / 1,2-1,5 Nm (N)
0.8 - 2 mm
(except N 0.5 MU)
independent of position

Protective Devices
Tripping Characteristics (IEC/EN 60898-1)
Tripping characteristic C

TRIPPING CURRENT

Minutes
TRIPPING TIME
TRIPPING CURRENT

Seconds

TRIPPING TIME

Minutes

Tripping characteristic D

Seconds

Seconds

TRIPPING TIME

Minutes

Tripping characteristic B

TRIPPING CURRENT

Quick-acting (B), slow (C), very slow (D)

Effect of the Ambient Temperature on Thermal Tripping Load Capacity of Series Connected Miniature Circuit
Breakers
Behaviour
Adjusted rated current values according to the ambient temperature

Load capacity factor KN

Ambient temperature T [C]

Number of devices (n) 1-pole

Effect of Power Frequency


Effect of power frequency on the tripping behaviour IMA of the quick release

IMA(f)/IMA(50Hz) [%]

Power frequency f [Hz]


50
60
100
162/3
91
100
101
106

200
115

300
134

400
141

67

Protective Devices
Let-through energy PLSM, characteristic B, 1-pole

Let-through energy PLSM, characteristic C, 1-pole

Let through energy I2t [A2 sec]

Let through energy I2t [A2 sec]

Let-through Energy PLSM

Prospective short-circuit current [A]

Prospective short-circuit current [A]

Let through energy I2t [A2 sec]

Let-through energy PLSM, characteristic D, 1-pole

Prospective short-circuit current [A]

68

Protective Devices
Short Circuit Selectivity PLSM towards DII-DIV fuse link
In case of short circuit, there is selectivity between the miniature circuit breakers PLSM and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link DII-DIV*)

Short circuit selectivity characteristic C towards fuse link DII-DIV*)

PLSM DII-DIV gL/gG

PLSM DII-DIV gL/gG

In [A]

10

In [A]

10

16

1.0

<0.51) 1.2

16

20

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

25

35

50

63

80

100

0.75

1.0

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

20

25

35

50

63

80

100

1.5

<0.51) 1.0

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

2.0

<0.51)

0.8

2.5

<0.51) <0.51) 0.8

3.0

<0.51)

1.0

<0.51) 1.2

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.6

10.02)

10.02)

1.5

<0.51)

1.0

2.2

10.02) 10.02) 10.02) 10.02) 10.02)

1.5

10.02) 10.02) 10.02) 10.02) 10.02)

0.8

3.5

<0.51) <0.51) 0.7

<0.51)

0.6

1.0

<0.51) <0.51) 0.6

0.9

<0.51)

<0.51)

<0.51)

10.02)

10.02)

10.02)

<0.51)

2.0

<0.51) <0.51) 0.8

1.6

10.02) 10.02) 10.02) 10.02) 10.02)

1.4

10.02)

10.02)

2.5

<0.51)

0.8

1.4

10.02) 10.02) 10.02) 10.02) 10.02)

1.3

10.02) 10.02) 10.02) 10.02) 10.02)

3.0

<0.51) <0.51) 0.8

0.9

10.02) 10.02) 10.02) 10.02) 10.02)

3.5

<0.51)

0.6

0.9

2.2

4.5

10.02) 10.02) 10.02)

10.02)

10.02)

10.02)

10.02)

<0.51)

3.6

10.02)

10.02)

10.02)

<0.51)

2.0

3.5

8.5

10.02) 10.02)

<0.51) <0.51) 0.6

0.8

1.8

3.6

9.7

10.02) 10.02)

10.02)

<0.51)

0.6

0.7

1.5

2.7

7.3

10.02) 10.02)

<0.51)

0.6

0.9

1.8

3.2

7.4

10.02)

<0.51)

<0.51) 0.5

0.8

1.6

2.6

5.2

8.3

10.02)

<0.51) 0.5

0.6

1.4

2.4

5.5

10.02) 10.02)

<0.51)

0.6

1.3

2.2

4.7

8.7

10.02)

<0.51) 0.6

1.3

2.0

3.6

5.4

10.02)

10

0.5

0.8

1.4

2.2

3.9

6.0

10.02)

13

0.5

0.7

1.3

2.0

3.6

5.4

10.02)

10

0.6

1.2

1.9

3.2

4.6

8.4

13

1.3

1.9

3.3

5.0

9.4

20

1.2

1.8

3.1

4.4

7.8

16

1.2

1.8

3.2

4.4

8.0

25

1.2

1.8

3.0

4.2

7.3

20

1.2

1.8

3.1

4.1

7.0

16

32

2.8

3.9

6.8

25

40

1.7

2.7

3.8

6.5

32

50

2.5

3.5

5.7

40

5.3

50

63

<0.51)

1.7

2.8

3.8

6.5

2.7

3.7

6.2

3.5

5.9

63
Short circuit selectivity characteristic D towards fuse link DII-DIV*)
1)

PLSM DII-DIV gL/gG


In [A]

10

2)

16

20

25

35

50

63

80

100

3.0

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

0.5

0.5

1.0

<0.51) <0.51) 1.0

2.4

10.02) 10.02) 10.02) 10.02) 10.02)

1.5

<0.51)

0.7

1.2

3.5

7.7

10.02) 10.02) 10.02)

2.0

<0.51) <0.51) 0.6

1.0

2.8

5.8

10.02) 10.02) 10.02)

2.5

<0.51)

0.6

1.4

2.3

4.6

10.02) 10.02) 10.02)

3.0

<0.51) <0.51) 0.6

0.9

2.3

4.3

10.02) 10.02) 10.02)

3.5

<0.51)

0.6

0.9

2.1

4.0

10.02) 10.02) 10.02)

<0.51) 0.6

0.9

2.0

3.8

9.5

10.02) 10.02)

<0.51)

0.5

0.7

1.7

3.1

7.0

10.02) 10.02)

0.5

0.7

1.5

2.6

5.3

9.1

10.02)

<0.51)

0.7

1.4

2.2

3.9

6.0

10.02)

0.7

1.2

1.9

3.4

5.0

9.5

1.2

10
13

<0.51)

<0.51)

<0.51)

1.8

3.2

4.6

8.6

16

1.6

2.7

4.0

7.4

20

1.5

25
32
40

2.5

3.5

6.7

2.4

3.4

6.2

2.8

5.0
4.8

69

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

5.5

Protective Devices
Short Circuit Selectivity PLSM towards D01-D03 fuse link
In case of short circuit, there is selectivity between the miniature circuit breakers PLSM and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link D01-D03*)

Short circuit selectivity characteristic C towards fuse link D01-D03*)

PLSM D01-D03 gL/gG

PLSM D01-D03 gL/gG

In [A]

10

In [A]

10

1.0

<0.51) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

16

20

25

35

50

63

80

100

0.75

<0.51) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.5

<0.51) 4.1

2.0

<0.51)

20

25

35

50

63

80

100

0.6

2.5

<0.51) <0.51) 0.6

3.0

<0.51)

1.0

<0.51) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.0

10.02)

10.02)

1.5

<0.51) 0.5

0.6

0.9

10.02) 10.02) 10.02) 10.02) 10.02)

1.0

10.02) 10.02) 10.02) 10.02) 10.02)

2.0

<0.51) <0.51) 0.5

0.7

10.02) 10.02) 10.02) 10.02) 10.02)

0.5

1.0

10.02)

10.02)

10.02)

2.5

<0.51)

0.7

10.02) 10.02) 10.02) 10.02) 10.02)

3.5

<0.51) <0.51) 0.5

0.9

7.0

10.02) 10.02) 10.02) 10.02)

3.0

<0.51) <0.51) <0.51) 0.6

1.9

5.2

10.02) 10.02) 10.02)

<0.51)

10.02)

10.02)

3.5

<0.51)

0.6

1.8

4.7

9.5

10.02) 10.02)

7.0

10.02) 10.02)

<0.51) <0.51) <0.51) 0.6

1.6

4.0

7.6

10.02) 10.02)

10.02)

<0.51)

1.3

3.1

5.7

10.02) 10.02)

<0.51)

<0.51)

<0.51)

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

16

10.02)

0.5

0.9

2.5

10.02)

<0.51) 0.5

0.8

1.7

4.0

<0.51)

10.02)

10.02)

10.02)

10.02)

10.02)

<0.51)

<0.51)

0.5

<0.51)

0.5

0.8

1.6

3.6

6.0

10.02)

<0.51)

0.5

0.8

1.4

2.8

4.3

8.2

10.02)

<0.51) <0.51) <0.51) 1.2

2.7

4.5

10.02) 10.02)

<0.51)

1.2

2.5

4.0

8.6

10.02)

10

0.5

0.7

1.3

2.4

3.4

6.0

10.02)

13

<0.51) 0.7

1.2

2.3

3.2

5.3

10.02)

10

<0.51) <0.51) 1.2

2.3

3.1

5.4

10.02)

16

0.6

1.1

2.2

2.9

4.6

10.0

13

1.1

2.2

3.0

4.9

10.02)

20

1.1

2.1

2.8

4.4

9.3

16

1.1

2.1

2.8

4.4

9.5

25

1.1

2.0

2.7

4.2

8.7

20

1.0

2.0

2.6

4.0

8.3

2.0

1.9

2.5

3.8

7.8

2.5

3.7

7.3

3.5

7.0

32

2.6

4.0

8.0

25

40

2.5

3.8

7.5

32

50

2.3

3.4

6.7

40

6.2

50

63

<0.51)

0.5

<0.51)

63
Short circuit selectivity characteristic D towards fuse link D01-D03*)
1)

PLSM D01-D03 gL/gG

2)

In [A]

10

16

20

25

35

50

63

80

100

0.5

<0.51)

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

1.0

<0.51) <0.51) 0.7

1.3

10.02) 10.02) 10.02) 10.02) 10.02)

1.5

<0.51)

0.6

0.9

2.8

9.0

10.02) 10.02) 10.02)

2.0

<0.51) <0.51) 0.6

0.8

2.2

6.7

10.02) 10.02) 10.02)

2.5

<0.51)

0.5

0.7

1.9

5.4

10.02) 10.02) 10.02)

3.0

<0.51) <0.51) 0.5

0.7

1.8

4.8

9.3

10.02) 10.02)

3.5

<0.51)

0.5

0.7

1.7

4.7

8.6

10.02) 10.02)

<0.51) 0.5

0.7

1.7

4.6

7.7

10.02) 10.02)

<0.51)

0.6

1.5

3.5

5.8

10.02) 10.02)

<0.51) 0.5

1.3

2.9

4.5

9.0

10.02)

<0.51)

0.5

1.2

2.4

3.5

6.0

10.02)

0.5

1.1

2.2

3.0

5.0

10.02)

1.1

2.1

2.9

4.6

10.02)

16

1.9

2.6

3.9

9.0

20

1.7

2.3

3.5

8.0

2.2

3.4

7.5

2.9

6.0

10
13

25
32
40

<0.51)

<0.51)

<0.51)

<0.51)

5.7

70

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

6.5

Protective Devices
Short Circuit Selectivity PLSM towards NH-00 Fuses
In case of short circuit, there is selectivity between the miniature circuit breakers PLSM and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link NH-00*)

Short circuit selectivity characteristic C towards fuse link NH-00*)

PLSM NH-00 gL/gG

PLSM NH-00 gL/gG

In [A] 16

20

1.0

0.9

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

0.75

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.5

0.8

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

2.0

<0.51)

0.5

1.0

2.5

<0.51) 0.5

1.0

3.0

<0.51)

0.5

0.9

2.1

3.5

<0.51) 0.5

0.9

1.8

<0.51)

0.8

1.3

2.3

<0.51) <0.51) 0.7

1.1

1.6

<0.51)

0.7

1.1

1.5

2.0

3.3

<0.51) <0.51) 0.6

1.0

1.3

1.7

2.6

<0.51)

<0.51)

25

32

35

40

50

63

80

100 125 160

In [A] 16

20

25

32

35

40

50

63

80

100 125 160

1.0

0.9

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

2.5

10.02)

10.02)

1.5

<0.51)

0.6

1.3

4.2

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

2.3

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

2.0

<0.51) 0.6

1.0

2.5

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

8.0

10.02)

10.02)

2.5

<0.51)

1.0

2.1

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

5.5

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

3.0

<0.51) <0.51) 0.7

1.2

1.8

2.6

4.7

6.6

10.02) 10.02) 10.02) 10.02)

3.5

<0.51)

0.7

1.1

1.7

2.4

4.2

6.0

10.02) 10.02) 10.02) 10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

4.3

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

2.2

3.6

4.8

8.9

10.02) 10.02) 10.02)

4.3
3.3

0.5

<0.51)

<0.51) <0.51) 0.7

1.0

1.5

2.1

3.6

5.0

10.0

10.02) 10.02) 10.02)

7.6

10.02)

10.02)

<0.51)

0.6

0.8

1.2

1.7

2.8

3.8

8.7

10.02) 10.02) 10.02)

5.2

10.02) 10.02) 10.02)

<0.51) <0.51) 0.5

0.8

1.2

1.5

2.5

3.3

5.7

10.02) 10.02) 10.02)

<0.51)

0.5

0.8

1.1

1.5

2.3

2.9

4.9

10.02) 10.02) 10.02)

0.5

0.7

1.0

1.4

2.0

2.5

3.8

8.0

10.02) 10.02)

10.02)

10

<0.51)

0.6

0.9

1.2

1.5

2.2

2.7

4.0

9.0

10.02)

13

<0.51) 0.6

0.8

1.1

1.4

2.1

2.6

3.8

7.9

10.02) 10.02)

10
13

1.0

1.3

1.9

2.4

3.6

7.0

10.02) 10.02)

16

0.5

20
25

10.02)

<0.51)

<0.51)

0.7

1.0

1.3

1.9

2.4

3.4

6.4

9.3

10.02)

0.7

1.0

1.3

1.9

2.4

3.3

6.0

8.7

10.02)

16

1.0

1.3

1.8

2.3

3.3

6.0

8.8

10.02)

20

1.0

1.2

1.7

2.2

3.2

5.5

7.7

10.02)

1.6

2.1

3.0

5.2

7.3

10.02)

2.1

2.9

5.0

7.0

10.02)

2.8

4.8

6.7

10.0

4.5

6.3

9.5

5.9

8.4

0.7

32

1.0

1.3

1.8

2.3

3.2

5.7

8.0

10.02)

0.9

1.2

1.7

2.2

3.1

5.4

7.6

10.02)

25
32

40

2.1

3.0

5.1

7.2

10.02)

50

1.9

2.8

4.7

6.6

9.5

40

4.4

6.3

8.6

50

63

63
Short circuit selectivity characteristic D towards fuse link NH-00*)
1)

PLSM NH-00 gL/gG

2)

In [A] 16

20

25

32

35

40

50

63

80

100 125 160

0.5

2.1

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

10.02)

10.02) 10.02) 10.02)

1.0

<0.51) 0,6

1.4

4.3

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.5

<0.51)

0.9

1.6

2.7

4.0

8.0

10.02) 10.02) 10.02) 10.02) 10.02)

2.0

<0.51) <0.51) 0.8

1.3

2.1

3.1

6.0

8.6

10.02) 10.02) 10.02) 10.02)

2.5

<0.51)

0.7

1.2

1.8

2.6

4.8

6.9

10.02) 10.02) 10.02) 10.02)

3.0

<0.51) <0.51) 0.7

1.1

1.7

2.4

4.3

6.0

10.02) 10.02) 10.02) 10.02)

3.5

<0.51)

0.7

1.1

1.7

2.4

4.2

5.6

10.02) 10.02) 10.02) 10.02)

<0.51) <0.51) 0.7

1.0

1.6

2.2

3.8

5.2

10.0

10.02) 10.02) 10.02)

<0.51)

<0.51)

<0.51)

<0.51)

0.6

0.9

1.4

1.9

3.2

4.1

7.1

10.02) 10.02) 10.02)

<0.51) 0.5

0.8

1.2

1.6

2.6

3.3

5.5

10.02) 10.02) 10.02)

0.5

0.8

1.1

1.5

2.2

2.7

4.1

8.7

10.02) 10.02)

10

0.5

0.7

1.0

1.3

1.9

2.5

3.6

7.2

10.02) 10.02)

1.0

1.3

1.9

2.3

3.4

6.5

9.5

10.02)

1.1

1.6

2.0

3.0

5.5

8.0

10.02)

1.4

1.8

2.8

5.0

7.5

10.02)

1.8

2.7

4.8

7.0

10.02)

2.4

4.1

6.2

9.3

4.0

6.0

9.0

13
16
20
25
32
40

71

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

Protective Devices
Short Circuit Selectivity PLSM towards cylindrical fuse links
In case of short circuit, there is selectivity between the miniature circuit breakers PLSM and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse links CH10x38 gG, CH14x51 gG, CH22x58 gG*)

PLSM CH10x38 gG

CH15x51 gG

CH22x58 gG

In [A] 16

20

25

32

20

25

32

40

50

16

20

25

32

40

50

63

80

100

0.5

>10

>10

>10

>10

>10

>10

>10

>10

1.2

>10

>10

>10

>10

>10

>10

>10

>10

<0.5 0.6

1.2

3.6

0.5

1.0

5.2

>10

>10

<0.5 0.5

1.1

>10

>10

>10

>10

>10

>10

<0.5 0.5

0.8

1.4

0.5

0.9

3.7

>10

>10

<0.5 0.5

1.0

8.0

>10

>10

>10

>10

>10

<0.5 <0.5 0.7

1.2

<0.5 0.7

1.7

4.0

>10

<0.5 <0.5 0.8

2.3

5.1

>10

>10

>10

>10

<0.5 <0.5 0.6

0.9

<0.5 0.7

1.3

2.0

2.7

<0.5 <0.5 0.7

1.5

2.2

2.6

5.6

10

>10

10

<0.5 <0.5 0.6

0.9

<0.5 0.6

1.1

1.5

2.0

<0.5 <0.5 0.6

1.2

1.6

1.9

3.2

4.8

9.0

13

<0.5 <0.5 0.6

0.8

<0.5 0.6

1.0

1.4

1.9

<0.5 <0.5 0.6

1.2

1.5

1.7

3.0

4.3

7.7

16

<0.5 0.5

0.8

<0.5 0.5

1.0

1.4

1.8

<0.5 0.5

1.1

1.4

1.6

2.7

3.8

6.3

20

0.5

0.8

<0.5 0.9

1.3

1.6

0.5

1.1

1.4

1.6

2.6

3.7

6.0

0.7

0.9

1.3

1.6

1.0

1.3

1.5

2.5

3.5

5.6

1.2

1.5

1.3

1.5

2.4

3.3

5.2

1.4

2.3

3.2

5.0

2.1

2.9

4.5

2.8

4.2

25
32
40

1.5

50
63

no selectivity

Short circuit selectivity characteristic C towards fuse links CH10x38 gG, CH14x51 gG, CH22x58 gG*)

PLSM CH10x38 gG

CH15x51 gG

CH22x58 gG

In [A] 16

20

25

32

20

25

32

40

50

16

20

25

32

40

50

63

80

100

0.5

1.9

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

<0.5 >10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

<0.5 0.6

1.2

3.6

0.5

1.0

4.5

>10

>10

<0.5 0.6

1.1

>10

>10

>10

>10

>10

>10

<0.5 0.5

0.8

1.4

<0.5 0.7

1.4

2.4

3.7

<0.5 <0.5 0.8

1.8

2.7

3.5

9.3

>10

>10

<0.5 <0.5 0.7

1.2

<0.5 0.7

1.2

2.0

2.9

<0.5 <0.5 0.7

1.5

2.2

2.7

6.7

>10

>10

<0.5 <0.5 0.6

0.9

<0.5 <0.5 1.0

1.4

2.0

<0.5 <0.5 0.6

1.1

1.6

1.9

4.2

7.0

>10

10

<0.5 <0.5 0.5

0.8

<0.5 <0.5 0.9

1.3

1.7

<0.5 <0.5 0.6

1.1.

1.5

1.8

2.9

4.1

7.5

13

<0.5 <0.5 0.5

0.8

<0.5 <0.5 0.9

1.3

1.7

<0.5 <0.5 0.5

1.0

1.4

1.7

2.7

3.8

6.5

16

<0.5 0.5

0.8

<0.5 <0.5 0.8

1.2

1.6

<0.5 <0.5 1.0

1.3

1.5

2.6

3.5

5.8

20

<0.5 0.7

<0.5 0.8

1.2

1.5

<0.5 0.9

1.2

1.4

2.5

3.3

5.4

25

0.7

0.8

1.1

1.4

0.9

1.2

1.4

2.3

3.2

5.0

1.1

1.4

1.1

1.3

2.2

3.0

4.8

1.2

2.0

2.8

4.6

1.9

2.6

4.2

2.3

3.7

32
40

1.3

50
63

72

no selectivity

Protective Devices
Short circuit selectivity characteristic D towards fuse links CH10x38 gG, CH14x51 gG, CH22x58 gG*)

PLSM CH10x38 gG

CH15x51 gG

CH22x58 gG

In [A] 16

20

25

32

20

25

32

40

50

16

20

25

32

40

50

63

80

100

0.5

0.9

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

>10

<0.5 >10

>10

>10

>10

>10

>10

>10

>10

<0.5 0.6

1.5

>10

>10

>10

>10

>10

>10

<0.5 0.5

0.6

1.6

<0.5 1.0

1.7

>10

>10

<0.5 0.5

0.8

2.1

3.3

4.3

>10

>10

>10

<0.5 <0.5 0.8

1.3

<0.5 0.7

1.4

2.4

3.4

<0.5 <0.5 0.7

1.7

2.5

3.2

8.2

>10

>10

<0.5 <0.5 0.7

1.2

<0.5 0.7

1.3

2.0

3.1

<0.5 <0.5 0.7

1.6

2.3

3.0

7.0

>10

>10

<0.5 <0.5 0.6

1.0

<0.5 <0.5 1.0

1.6

2.0

<0.5 <0.5 0.6

1.3

1.7

2.1

4.2

7.0

>10

10

<0.5 <0.5 0.6

0.8

<0.5 <0.5 0.9

1.3

1.7

<0.5 <0.5 0.5

1.1

1.4

1.6

2.8

4.1

7.1

13

<0.5 <0.5 0.5

0.8

<0.5 <0.5 0.9

1.3

1.6

<0.5 <0.5 0.5

1.0

1.4

1.6

2.7

3.8

6.5

16

<0.5 0.5

0.7

<0.5 <0.5 0.8

1.1

1.4

<0.5 <0.5 1.0

1.2

1.4

2.3

3.2

5.5

20

<0.5 0.7

<0.5 0.7

1.0

1.3

<0.5 0.8

1.1

1.3

2.1

2.9

4.6

25

0.7

0.7

1.0

1.2

0.8

1.0

1.2

2.0

2.8

4.0

0.9

1.0

1.7

2.3

3.8

1.0

2.0

2.2

3.6

32
40

73

no selectivity

Protective Devices
Let-through energy PLS6, characteristic B, 1-pole

Let-through energy PLS6, characteristic C, 1-pole

Let through energy I2t [A2 sec]

Let through energy I2t [A2 sec]

Let-through Energy PLS6

Prospective short-circuit current [A]

Prospective short-circuit current [A]

Let through energy I2t [A2 sec]

Let-through energy PLS6, characteristic D, 1-pole

Prospective short-circuit current [A]

74

Protective Devices
Short Circuit Selectivity PLS6 towards DII-DIV fuse link
In case of short circuit, there is selectivity between the miniature circuit breakers PLS6 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link DII-DIV*)

Short circuit selectivity characteristic C towards fuse link DII-DIV*)

PLS6

DII-DIV gL/gG

PLS6

In [A]

10

20

25

35

50

63

80

100

In [A]

10

16

20

25

35

50

63

80

100

1.0

<0.51) 1.2

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

0.75

1.0

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

1.5

<0.51) 1.0

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

1.0

<0.51) 1.2

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

2.0

<0.51)

0.8

1.6

6.02)

6.02)

6.02)

6.02)

6.02)

1.5

<0.51)

1.0

2.2

6.02)

6.02)

6.02)

6.02)

6.02)

2.5

<0.51) <0.51) 0.8

1.5

6.02)

6.02)

6.02)

6.02)

6.02)

2.0

<0.51) <0.51) 0.8

1.6

6.02)

6.02)

6.02)

6.02)

6.02)

3.0

<0.51)

0.8

1.4

6.02)

6.02)

6.02)

6.02)

6.02)

2.5

<0.51)

0.8

1.4

6.02)

6.02)

6.02)

6.02)

6.02)

3.5

<0.51) <0.51) 0.7

1.3

6.02)

6.02)

6.02)

6.02)

6.02)

3.0

<0.51) <0.51) 0.8

0.9

6.02)

6.02)

6.02)

6.02)

6.02)

<0.51)

0.6

1.0

3.6

6.02)

6.02)

6.02)

6.02)

3.5

<0.51)

0.6

0.9

2.2

4.5

6.02)

6.02)

6.02)

<0.51) <0.51) 0.6

0.9

2.0

3.5

6.02)

6.02)

6.02)

<0.51) <0.51) 0.6

0.8

1.8

3.6

6.02)

6.02)

6.02)

6.02)

6.02)

<0.51)

6.02)

6.02)

16

<0.51)

<0.51)

<0.51)

<0.51)

0.6

0.9

1.8

3.2

6.02)

<0.51) 0.5

0.8

1.6

2.6

5.2

6.02)

6.02)
6.02)

1.5

2.7

<0.51) 0.5

0.6

1.4

2.4

5.5

6.02)

6.02)

<0.51)

6.02)

0.8

1.4

2.2

3.9

13

0.5

0.7

1.3

2.0

3.6

5.4

6.02)

10

25

<0.51)

0.7

0.5

20

<0.51)

0.6

10

0.6

<0.51)

6.02)

6.02)

16

DII-DIV gL/gG

<0.51)

<0.51)

0.6

1.3

2.2

4.7

6.02)

<0.51) 0.6

1.3

2.0

3.6

6.02)

6.02)

13

1.3

1.9

3.3

5.0

6.02)

1.2

1.9

3.2

4.6

6.02)

1.2

1.8

3.1

4.4

6.02)

16

1.2

1.8

3.2

4.4

6.02)

20

1.2

1.8

3.1

4.1

6.02)

1.7

2.8

3.8

6.02)

2.7

3.7

6.02)

3.5

5.9

1.2

32

1.8

3.0

4.2

6.02)

1.7

2.8

3.9

6.02)

25
32

40

2.7

3.8

6.02)

50

2.5

3.5

5.7

40

5.3

50

63

63
Short circuit selectivity characteristic D towards fuse link DII-DIV*)

PLS6

DII-DIV gL/gG

In [A]

10

1)
2)

16

20

25

35

50

63

80

100

3.0

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

2.4

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

0.5

0.5

1.0

<0.51) <0.51) 1.0

1.5

<0.51)

0.7

1.2

3.5

6.02)

2.0

<0.51) <0.51) 0.6

1.0

2.8

5.8

6.02)

6.02)

6.02)

2.5

<0.51)

0.6

1.4

2.3

4.6

6.02)

6.02)

6.02)

3.0

<0.51) <0.51) 0.6

0.9

2.3

4.3

6.02)

6.02)

6.02)

3.5

<0.51)

6.02)

6.02)

<0.51)

<0.51)

<0.51)

0.6

0.9

2.1

4.0

6.02)

<0.51) 0.6

0.9

2.0

3.8

6.02)

6.02)

6.02)

<0.51)

6.02)

6.02)

0.5

0.7

1.7

3.1

6.02)

0.5

0.7

1.5

2.6

5.3

6.02)

6.02)

<0.51)

6.02)

0.7

1.4

2.2

3.9

6.02)

0.7

1.2

1.9

3.4

5.0

6.02)

1.2

1.8

3.2

4.6

6.02)

16

1.6

2.7

4.0

6.02)

20

1.5

2.5

3.5

6.02)

2.4

3.4

6.02)

2.8

5.0

10
13

25
32
40

4.8

75

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

5.5

Protective Devices
Short Circuit Selectivity PLS6 towards D01-D03 fuse link
In case of short circuit, there is selectivity between the miniature circuit breakers PLS6 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link D01-D03*)

Short circuit selectivity characteristic C towards fuse link D01-D03*)

PLS6

PLS6

D01-D03 gL/gG
16

D01-D03 gL/gG

In [A]

10

20

25

35

50

63

80

100

In [A]

10

20

25

35

50

63

80

100

1.0

<0.51) 6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

0.75

<0.51) 6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

1.5

<0.51) 4.1

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

1.0

<0.51) 6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

2.0

<0.51)

0.6

1.0

6.02)

6.02)

6.02)

6.02)

6.02)

1.5

<0.51)

0.6

0.9

6.02)

6.02)

6.02)

6.02)

6.02)

2.5

<0.51) <0.51) 0.6

1.0

6.02)

6.02)

6.02)

6.02)

6.02)

2.0

<0.51) <0.51) 0.5

0.7

6.02)

6.02)

6.02)

6.02)

6.02)

3.0

<0.51)

0.5

1.0

6.02)

6.02)

6.02)

6.02)

6.02)

2.5

<0.51)

0.7

6.02)

6.02)

6.02)

6.02)

6.02)

3.5

<0.51) <0.51) 0.5

0.9

6.02)

6.02)

6.02)

6.02)

6.02)

3.0

<0.51) <0.51) <0.51) 0.6

1.9

5.2

6.02)

6.02)

6.02)

<0.51)

6.02)

6.02)

6.02)

3.5

<0.51)

0.6

1.8

4.7

6.02)

6.02)

6.02)

<0.51) <0.51) <0.51) 0.6

1.6

4.0

6.02)

6.02)

6.02)
6.02)

<0.51)

<0.51)

<0.51)

16

0.5

<0.51)

0.5

0.9

2.5

6.02)

<0.51) 0.5

0.8

1.7

4.0

6.02)

6.02)

6.02)

<0.51)

6.02)

6.02)

<0.51)

1.3

3.1

5.7

6.02)

2.7

4.5

6.02)

6.02)
6.02)

<0.51)

0.5

<0.51)

0.5

0.8

1.6

3.6

6.02)

0.5

0.8

1.4

2.8

4.3

6.02)

6.02)

<0.51) <0.51) <0.51) 1.2

6.02)

<0.51)

10

0.5

0.7

1.3

2.4

3.4

6.02)

13

<0.51) 0.7

1.2

2.3

3.2

5.3

6.02)

16

0.6

20
25

<0.51)

<0.51)

0.5

<0.51)

1.2

2.5

4.0

6.02)

10

<0.51) <0.51) 1.2

2.3

3.1

5.4

6.02)

13

1.1

2.2

3.0

4.9

6.02)

1.1

2.2

2.9

4.6

6.02)

1.1

2.1

2.8

4.4

6.02)

16

1.1

2.1

2.8

4.4

6.02)

20

1.0

2.0

2.6

4.0

6.02)

1.9

2.5

3.8

6.02)

2.5

3.7

6.02)

3.5

6.02)

1.1

32

2.0

2.7

4.2

6.02)

2.0

2.6

4.0

6.02)

25
32

40

2.5

3.8

6.02)

50

2.3

3.4

6.02)

40

6.02)

50

63

63
Short circuit selectivity characteristic D towards fuse link D01-D03*)
1)

PLS6

D01-D03 gL/gG

In [A]

10

16

20

25

35

50

63

80

100

0.5

<0.51)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

1.0

<0.51) <0.51) 0.7

1.3

6.02)

6.02)

6.02)

6.02)

6.02)

1.5

<0.51)

0.6

0.9

2.8

6.02)

6.02)

6.02)

6.02)

2.0

<0.51) <0.51) 0.6

0.8

2.2

6.02)

6.02)

6.02)

6.02)

2.5

<0.51)

0.5

0.7

1.9

5.4

6.02)

6.02)

6.02)

3.0

<0.51) <0.51) 0.5

0.7

1.8

4.8

6.02)

6.02)

6.02)

3.5

<0.51)

6.02)

6.02)

<0.51)

<0.51)

<0.51)

2)

0.5

0.7

1.7

4.7

6.02)

<0.51) 0.5

0.7

1.7

4.6

6.02)

6.02)

6.02)

<0.51)

6.02)

<0.51)

0.6

1.5

3.5

5.8

6.02)

<0.51) 0.5

1.3

2.9

4.5

6.02)

6.02)

<0.51)

6.02)

0.5

1.2

2.4

3.5

6.02)

0.5

1.1

2.2

3.0

5.0

6.02)

1.1

2.1

2.9

4.6

6.02)

16

1.9

2.6

3.9

6.02)

20

1.7

2.3

3.5

6.02)

2.2

3.4

6.02)

2.9

6.02)

10
13

25
32
40

5.7

76

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

6.02)

Protective Devices
Short Circuit Selectivity PLS6 towards NH-00 Fuses
In case of short circuit, there is selectivity between the miniature circuit breakers PLS6 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link NH-00*)

Short circuit selectivity characteristic C towards fuse link NH-00*)

PLS6 NH-00 gL/gG

PLS6 NH-00 gL/gG

In [A] 16

20

1.0

0.9

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

0.75

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

1.5

0.8

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

2.0

<0.51)

0.5

1.0

2.5

<0.51) 0.5

1.0

3.0

<0.51)

0.5

3.5

<0.51) 0.5

<0.51)

0.8

1.3

2.3

<0.51) <0.51) 0.7

1.1

1.6

<0.51)

0.7

1.1

1.5

2.0

<0.51) <0.51) 0.6

1.0

1.3

1.7

<0.51)

<0.51)

25

32

35

40

50

63

80

100 125 160

In [A] 16

20

25

32

35

40

50

63

80

100 125 160

1.0

0.9

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

2.5

6.02)

6.02)

1.5

<0.51)

0.6

1.3

4.2

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

2.3

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

2.0

<0.51) 0.6

1.0

2.5

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

0.9

2.1

6.02)

6.02)

6.02)

2.5

<0.51)

1.0

2.1

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

0.9

1.8

5.5

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

3.0

<0.51) <0.51) 0.7

1.2

1.8

2.6

4.7

6.02) 6.02) 6.02) 6.02) 6.02)

3.5

<0.51)

0.7

1.1

1.7

2.4

4.2

6.02) 6.02) 6.02) 6.02) 6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

4.3

6.02)

6.02)

6.02)

2.2

3.6

4.8

6.02) 6.02) 6.02) 6.02)

<0.51) <0.51) 0.7

1.0

1.5

2.1

3.6

5.0

6.02) 6.02) 6.02) 6.02)

3.3

4.3

6.02)

6.02)

6.02)

<0.51)

0.6

0.8

1.2

1.7

2.8

3.8

6.02) 6.02) 6.02) 6.02)

2.6

3.3

5.2

6.02) 6.02) 6.02)

<0.51) <0.51) 0.5

0.8

1.2

1.5

2.5

3.3

5.7

6.02) 6.02) 6.02)

<0.51)

0.5

0.8

1.1

1.5

2.3

2.9

4.9

6.02) 6.02) 6.02)

0.5

0.7

1.0

1.4

2.0

2.5

3.8

6.02) 6.02) 6.02)

6.02)

<0.51)

10

0.6

0.9

1.2

1.5

2.2

2.7

4.0

6.02)

13

<0.51) 0.6

0.8

1.1

1.4

2.1

2.6

3.8

6.02) 6.02) 6.02)

10

6.02)

13

1.0

1.3

1.9

2.4

3.6

6.02) 6.02) 6.02)

0.5

20
25

<0.51)

0.7

1.0

1.3

1.9

2.4

3.4

6.02)

0.7

1.0

1.3

1.9

2.4

3.3

6.02) 6.02) 6.02)

16

1.0

1.3

1.8

2.3

3.3

6.02) 6.02) 6.02)

6.02)

20

1.0

1.2

1.7

2.2

3.2

5.5

6.02) 6.02)

1.6

2.1

3.0

5.2

6.02) 6.02)

2.1

2.9

5.0

6.02) 6.02)

2.8

4.8

6.02) 6.02)

4.5

6.02) 6.02)

0.7

32

6.02)

6.02)

<0.51)

<0.51)

16

6.02)

6.02)

0.5

1.0

1.3

1.8

2.3

3.2

5.7

6.02)

0.9

1.2

1.7

2.2

3.1

5.4

6.02) 6.02)

25

6.02)

32

40

2.1

3.0

5.1

6.02)

50

1.9

2.8

4.7

6.02) 6.02)

40

4.4

6.02)

50

63

6.02)

63

5.9

Short circuit selectivity characteristic D towards fuse link NH-00*)


1)

PLS6 NH-00 gL/gG

2)

In [A] 16

20

25

32

35

40

50

63

80

100 125 160

0.5

2.1

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)

6.02) 6.02) 6.02)

1.0

<0.51) 0,6

1.4

4.3

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

1.5

<0.51)

0.9

1.6

2.7

4.0

6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

2.0

<0.51) <0.51) 0.8

1.3

2.1

3.1

6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

2.5

<0.51)

0.7

1.2

1.8

2.6

4.8

6.02) 6.02) 6.02) 6.02) 6.02)

3.0

<0.51) <0.51) 0.7

1.1

1.7

2.4

4.3

6.02) 6.02) 6.02) 6.02) 6.02)

3.5

<0.51)

0.7

1.1

1.7

2.4

4.2

5.6

6.02) 6.02) 6.02) 6.02)

<0.51) <0.51) 0.7

1.0

1.6

2.2

3.8

5.2

6.02) 6.02) 6.02) 6.02)

<0.51)

<0.51)

<0.51)

<0.51)

0.6

0.9

1.4

1.9

3.2

4.1

6.02) 6.02) 6.02) 6.02)

<0.51) 0.5

0.8

1.2

1.6

2.6

3.3

5.5

6.02) 6.02) 6.02)

0.5

0.8

1.1

1.5

2.2

2.7

4.1

6.02) 6.02) 6.02)

10

0.5

0.7

1.0

1.3

1.9

2.5

3.6

6.02) 6.02) 6.02)

1.0

1.3

1.9

2.3

3.4

6.02) 6.02) 6.02)

1.1

1.6

2.0

3.0

5.5

6.02) 6.02)

1.4

1.8

2.8

5.0

6.02) 6.02)

1.8

2.7

4.8

6.02) 6.02)

2.4

4.1

6.02) 6.02)

4.0

6.02) 6.02)

13
16
20
25
32
40

77

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

6.02)

Protective Devices
Let-through energy PLS4, characteristic B, 1-pole

Let-through energy PLS4, characteristic C, 1-pole

Let through energy I2t [A2 sec]

Let through energy I2t [A2 sec]

Let-through Energy PLS4

Prospective short-circuit current [A]

Prospective short-circuit current [A]

Short Circuit Selectivity PLS4 towards DII-DIV fuse link


In case of short circuit, there is selectivity between the miniature circuit breakers PLS4 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
1) Selectivity limit current I under 0.5 kA
*) basically in accordance with EN 60898-1 D.5.2.b
s
2)

Selectivity limit current Is = rated breaking capacity Icn of the MCB


no selectivity

Short circuit selectivity characteristic B towards fuse link DII-DIV*)

Short circuit selectivity characteristic C towards fuse link DII-DIV*)

PLS4

PLS4

DII-DIV gL/gG
16

DII-DIV gL/gG

In [A]

10

20

25

35

50

63

80

100

In [A]

10

16

20

25

35

50

63

80

100

1.0

<0.51) 1.2

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

0.75

1.0

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

<0.51) 1.0

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.0

<0.51) 1.2

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51) <0.51) 0.8

1.6

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

<0.51) <0.51) 1.0

2.2

4.52)

4.52)

4.52)

4.52)

4.52)

2.5

<0.51)

0.8

1.5

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51)

0.8

1.6

4.52)

4.52)

4.52)

4.52)

4.52)

3.0

<0.51) <0.51) 0.8

1.4

4.52)

4.52)

4.52)

4.52)

4.52)

2.5

<0.51) <0.51) 0.8

1.4

4.52)

4.52)

4.52)

4.52)

4.52)

3.5

<0.51)

0.7

1.3

4.52)

4.52)

4.52)

4.52)

4.52)

3.0

<0.51)

0.8

0.9

4.52)

4.52)

4.52)

4.52)

4.52)

<0.51) <0.51) 0.6

1.0

3.6

4.52)

4.52)

4.52)

4.52)

3.5

<0.51) <0.51) 0.6

0.9

2.2

4.52)

4.52)

4.52)

4.52)

<0.51)

4.52)

4.52)

<0.51)

0.6

0.8

1.8

3.6

4.52)

4.52)

4.52)

<0.51) <0.51) 0.6

0.7

1.5

2.7

4.52)

4.52)

4.52)

4.52)

4.52)

<0.51)

<0.51)

<0.51)

0.6

0.9

2.0

3.5

4.52)

<0.51) 0.6

0.9

1.8

3.2

4.52)

4.52)

4.52)

<0.51)

4.52)

4.52)

<0.51)

0.6

1.4

2.4

4.52)

<0.51) <0.51) 0.6

1.3

2.2

4.52)

4.52)

4.52)
4.52)

10
13
16

<0.51)

<0.51)

0.5

0.8

1.6

2.6

4.52)

0.5

0.8

1.4

2.2

3.9

4.52)

4.52)
4.52)

10

0.5

0.7

1.3

2.0

3.6

4.52)

0.6

1.2

1.9

3.2

4.52)

4.52)

1.3

2.0

3.6

13

1.3

1.9

3.3

4.52)

4.52)

16

1.2

1.8

3.2

4.4

4.52)

1.2

1.8

3.1

4.1

4.52)

1.7

2.8

3.8

4.52)

2.7

3.7

4.52)

3.5

4.52)

20

1.2

1.8

3.1

4.4

25

1.2

1.8

3.0

4.2

4.52)

20

2.8

3.9

4.52)

25

2.7

3.8

4.52)

32

3.5

4.52)

40

4.52)

50

40
50
63

1.7

2.5

63

78

0.5

4.52)

4.52)

32

<0.51)

<0.51)

0.6

4.52)

Protective Devices
In case of short circuit, there is selectivity between the miniature circuit breakers PLS4 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
1) Selectivity limit current I under 0.5 kA
s
*) basically in accordance with EN 60898-1 D.5.2.b
2) Selectivity limit current I = rated breaking capacity I of the MCB
s
cn
no selectivity

Short Circuit Selectivity PLS4 towards D01-D03 fuse link


Short circuit selectivity characteristic B towards fuse link D01-D03*)

Short circuit selectivity characteristic C towards fuse link D01-D03*)

PLS4

D01-D03 gL/gG

PLS4

D01-D03 gL/gG

In [A]

10

16

20

25

35

50

63

80

100

In [A]

10

16

20

25

35

50

63

80

100

1.0

<0.51)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

0.75

<0.51)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

<0.51) 4.1

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.0

<0.51) 4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51)

0.6

1.0

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

<0.51)

0.6

0.9

4.52)

4.52)

4.52)

4.52)

4.52)

2.5

<0.51) <0.51) 0.6

1.0

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51) <0.51) 0.5

0.7

4.52)

4.52)

4.52)

4.52)

4.52)

3.0

<0.51)

0.5

1.0

4.52)

4.52)

4.52)

4.52)

4.52)

2.5

<0.51)

0.7

4.52)

4.52)

4.52)

4.52)

4.52)

3.5

<0.51) <0.51) 0.5

0.9

4.52)

4.52)

4.52)

4.52)

4.52)

3.0

<0.51) <0.51) <0.51) 0.6

1.9

4.52)

4.52)

4.52)

4.52)

<0.51)

4.52)

4.52)

4.52)

3.5

<0.51)

0.6

1.8

4.52)

4.52)

4.52)

4.52)

<0.51) <0.51) <0.51) 0.6

1.6

4.0

4.52)

4.52)

4.52)

4.52)

4.52)

<0.51)

<0.51)

<0.51)

0.5

<0.51)

0.5

0.9

2.5

4.52)

<0.51) 0.5

0.8

1.7

4.0

4.52)

4.52)

4.52)

<0.51)

4.52)

4.52)

<0.51)

1.3

3.1

4.52)

2.7

4.52)

4.52)

4.52)
4.52)

<0.51)

0.5

<0.51)

0.5

0.8

1.6

3.6

4.52)

<0.51)

0.5

0.8

1.4

2.8

4.3

4.52)

4.52)

<0.51) <0.51) <0.51) 1.2

4.52)

<0.51)

10

10

0.5

0.7

1.3

2.4

3.4

4.52)

13

<0.51) 0.7

1.2

2.3

3.2

4.52)

4.52)
4.52)

13

1.1

16

0.6

20
25

<0.51)

0.5

<0.51)

1.2

2.5

4.0

4.52)

<0.51) <0.51) 1.2

2.3

3.1

4.52)

4.52)

2.2

3.0

4.52)

4.52)

1.1

2.2

2.9

4.52)

1.1

2.1

2.8

4.4

4.52)

16

1.1

2.1

2.8

4.4

4.52)

20

1.0

2.0

2.6

4.0

4.52)

1.9

2.5

3.8

4.52)

2.5

3.7

4.52)

3.5

4.52)

1.1

32

2.0

2.7

4.2

4.52)

2.0

2.6

4.0

4.52)

25
32

40

2.5

3.8

4.52)

50

2.3

3.4

4.52)

40

4.52)

50

63

4.52)

63

Short Circuit Selectivity PLS4 towards NH-00 fuse link


Short circuit selectivity characteristic B towards fuse link NH-00*)

Short circuit selectivity characteristic C towards fuse link NH-00*)

PLS4 NH-00 gL/gG

PLS4 NH-00 gL/gG

In [A] 16

20

25

32

35

40

50

63

80

100 125 160

1.0

0.9

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

0.8

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

2.0

<0.51)

0.5

1.0

2.5

<0.51) 0.5

1.0

3.0

<0.51)

0.5

3.5

<0.51) 0.5

<0.51)

0.8

1.3

2.3

<0.51) <0.51) 0.7

1.1

1.6

<0.51)

0.7

1.1

1.5

2.0

3.3

<0.51) <0.51) 0.6

1.0

1.3

1.7

2.6

<0.51)

<0.51)

4.52)

In [A] 16

4.52)

20

25

32

35

40

50

63

80

100 125 160

0.75

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52) 4.52) 4.52)

1.0

0.9

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

2.5

4.52)

4.52)

1.5

<0.51)

0.6

1.3

4.2

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

2.3

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

0.9
0.9

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51) 0.6

1.0

2.5

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

2.1

4.52)

4.52)

2.5

<0.51)

1.0

2.1

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

1.8

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

3.0

<0.51) <0.51) 0.7

1.2

1.8

2.6

4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

3.5

<0.51)

0.7

1.1

1.7

2.4

4.2

4.52) 4.52) 4.52) 4.52) 4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.3

4.52)

4.52)

4.52)

4.52)

2.2

3.6

4.52) 4.52) 4.52) 4.52) 4.52)

0.5

<0.51)

<0.51) <0.51) 0.7

1.0

1.5

2.1

3.6

4.52) 4.52) 4.52) 4.52) 4.52)

4.3

4.52)

4.52)

<0.51)

0.6

0.8

1.2

1.7

2.8

3.8

4.52) 4.52) 4.52) 4.52)

3.3

4.52) 4.52) 4.52) 4.52)

<0.51) <0.51) 0.5

0.8

1.2

1.5

2.5

3.3

4.52) 4.52) 4.52) 4.52)

<0.51)

0.5

0.8

1.1

1.5

2.3

2.9

4.52) 4.52) 4.52) 4.52)

0.5

0.7

1.0

1.4

2.0

2.5

3.8

4.52) 4.52) 4.52)

4.52)

4.52)

10

<0.51)

0.6

0.9

1.2

1.5

2.2

2.7

4.0

4.52)

13

<0.51) 0.6

0.8

1.1

1.4

2.1

2.6

3.8

4.52) 4.52) 4.52)

10

4.52)

13

1.0

1.3

1.9

2.4

3.6

4.52) 4.52) 4.52)

16
20
25
32

0.5

4.52)

<0.51)

0.7

1.0

1.3

1.9

2.4

3.4

4.52)

0.7

1.0

1.3

1.9

2.4

3.3

4.52) 4.52) 4.52)

16

1.0

1.3

1.8

2.3

3.3

4.52) 4.52) 4.52)

4.52)

20

1.0

1.2

1.7

2.2

3.2

4.52) 4.52) 4.52)

1.6

2.1

3.0

4.52) 4.52) 4.52)

2.1

2.9

4.52) 4.52) 4.52)

2.8

4.52) 4.52) 4.52)

0.7

4.52)

4.52)

<0.51)

1.0

1.3

1.8

2.3

3.2

4.52)

4.52)

0.9

1.2

1.7

2.2

3.1

4.52) 4.52) 4.52)

25

4.52)

32

40

2.1

3.0

4.52)

50

1.9

2.8

4.52) 4.52) 4.52)

40

4.52)

50

4.52) 4.52) 4.52)

63

4.52) 4.52)

63

4.4

4.52)

4.52)

79

Protective Devices
Miniature Circuit Breakers PLS6-DC
High selectivity between MCB and back-up fuse due to low let-through
energy
Compatible with standard busbar
Twin-purpose terminal (lift/open-mouthed) above and below
Busbar positioning optionally above or below
Meets the requirements of insulation co-ordination,
distance between contacts 4 mm, for secure isolation
Rated breaking capacity 10 kA according to IEC/EN 60947-2
Rated voltage up to 250 V (per pole), = 4 ms
Take into account polarity!

Accessories:
Auxiliary switch for
subsequent installation
Tripping signal contact for
subsequent installation
Remote control and automatic switching device
Shunt trip release
Undervoltage release
Compact enclosure
Additional terminal 35mm2
Switching interlock

ZP-IHK
ZP-NHK
Z-FW/LP
ZP-ASA/..
Z-USA/..
KLV-TC-2
KLV-TC-4
Z-HA-EK/35
Z-IS/SPE-1TE

286052
248437
248296
248438, 248439
248288-248291
276240
276241
263960
274418

Connection diagrams
1-pole

2-pole

Technical Data
Electrical
Design according to
IEC/EN 60947-2
Current test marks as printed onto the device
Rated voltage
DC
1-2 A type: 220V (per pole)
3-50 A types: 250V (per pole)
Rated breaking capacity
according to IEC/EN 60947-2
10 kA
Characteristic
C
Back-up fuse
max. 100 A gL
Selectivity class
3
Rated peak withstand voltage Uimp
4 kV (1.2/50s)
Endurance
electrical comp.
4,000 operating cycles
mechanical comp.
20,000 operating cycles
Line voltage connection
optional (above/below)

Mechanical
Frame size
Device height
Device width
Mounting

Degree of protection
Upper and lower terminals
Terminal protection
Terminal capacity
Terminal fastening torque
Busbar thickness
Mounting

Note: not for PV string protection!

Dimensions (mm)
1P

2P

Connection examples
Connection example at 250V=, 1-pole

Connection example at 500V=, 2-pole

80

45 mm
80 mm
17.5 mm per pole (1MU)
quick fastening with
3 lock-in positions on
DIN rail IEC/EN 60715
IP20
open mouthed/lift terminals
finger and hand touch safe,
BGV A3, VE-EN 6
1-25 mm2
2-2.4 Nm
0.8 - 2 mm
independent of position

Protective Devices
Tripping characteristic PLS6-DC

Let-through Energy PLS6-DC

Type C

Type C, 250 V d.c., = 5 ms (acc. to IEC/EN 60947-2)

81

Protective Devices
Miniature Circuit Breakers PL7
High selectivity between MCB and back-up fuse due to low let-through
energy
Twin-purpose terminal (lift/open-mouthed) above and below
Busbar positioning optionally above or below
Meets the requirements of insulation co-ordination,
distance between contacts 4 mm, for secure isolation
Suitable for applications up to 48 V DC (use PL7-DC for higher DC voltages)

Accessories:
Auxiliary switch for
subsequent installation

ZP-IHK
ZP-WHK

Tripping signal contact for


subsequent installation
Remote control and automatic switching device
Shunt trip release
Undervoltage release
Compact enclosure
Additional terminal 35mm2
Switching interlock

ZP-NHK
Z-FW/LP
ZP-ASA/..
Z-USA/..
KLV-TC-2
KLV-TC-4
Z-HA-EK/35
Z-IS/SPE-1TE

286052
286053
248437
248296
248438, 248439
248288-248291
276240
276241
263960
274418

Connection diagrams
1-pole

1+N-pole (1.5MU)

3-pole

3+N-pole

2-pole

Technical Data
Electrical
Design according to
IEC/EN 60898-1
Current test marks as printed onto the device
Rated voltage
AC: 230/400V
DC: 48V (per pole,
max. 2 poles)
Rated frequency
50/60 Hz
Rated breaking capacity
IEC/EN 60898-1
10 kA
Characteristic
B, C, D
Back-up fuse
max. 125 A gL
Selectivity class
3
Rated peak withstand voltage Uimp
4 kV (1.2/50s)
Endurance
electrical comp.
4,000 operating cycles
mechanical comp.
20,000 operating cycles
Line voltage connection
optional (above/below)

Mechanical
Frame size
Device height
Device width
Mounting

Degree of protection
Upper and lower terminals
Terminal protection
Terminal capacity
(1p+N, 1.5MU)
Terminal fastening torque
(1p+N, 1.5MU)
Busbar thickness
Mounting

Dimensions (mm)
2P

82

45 mm
80 mm
17.5 mm per pole (1MU)
26.3 mm: device 1P+N (1.5MU)
quick fastening with
3 lock-in positions on
DIN rail IEC/EN 60715
IP20
open mouthed/lift terminals
finger and hand touch safe,
BGV A3, VE-EN 6
1-25 mm2
1-25 mm2 / 1-2x10 mm2 (N)
2-2.4 Nm
2-2.4 Nm / 1,2-1,5 Nm (N)
0.8 - 2 mm
(except N 0.5 MU)
independent of position

Protective Devices
Tripping Characteristics (IEC/EN 60898-1)

TRIPPING CURRENT

TRIPPING TIME
TRIPPING CURRENT

Seconds

Minutes

Minutes
TRIPPING TIME

Seconds

Seconds

TRIPPING TIME

Tripping characteristic D

Tripping characteristic C

Minutes

Tripping characteristic B

TRIPPING CURRENT

Quick-acting (B), slow (C), very slow (D)

Effect of the Ambient Temperature on Thermal Tripping Load Capacity of Series Connected Miniature Circuit
Breakers
Behaviour
Adjusted rated current values according to the ambient temperature

Load capacity factor KN

Ambient temperature T [C]

Number of devices (n) 1-pole

Effect of Power Frequency


Effect of power frequency on the tripping behaviour IMA of the quick release

IMA(f)/IMA(50Hz) [%]

Power frequency f [Hz]


50
60
100
162/3
91
100
101
106

200
115

300
134

400
141

83

Protective Devices
Let-through energy PL7, characteristic B, 1-pole

Let-through energy PL7, characteristic C, 1-pole

Let through energy I2t [A2 sec]

Let through energy I2t [A2 sec]

Let-through Energy PL7

Prospective short-circuit current [A]

Prospective short-circuit current [A]

Let through energy I2t [A2 sec]

Let-through energy PL7, characteristic D, 1-pole

Prospective short-circuit current [A]

84

Protective Devices
Short Circuit Selectivity PL7 towards DII-DIV fuse link
In case of short circuit, there is selectivity between the miniature circuit breakers PL7 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link DII-DIV*)

Short circuit selectivity characteristic C towards fuse link DII-DIV*)

PL7

DII-DIV gL/gG

PL7

In [A]

10

20

25

35

<0.51) <0.51) 0.8

1.6

10.02) 10.02) 10.02) 10.02) 10.02)

<0.51) <0.51) 0.6

1.0

3.6

<0.51)

16

<0.51)

50

63

80

100

10.02) 10.02) 10.02) 10.02)

In [A]

10

16

0.75

1.0

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.0

<0.51) 1.2

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.6

<0.51)

1.0

2.2

10.02) 10.02) 10.02) 10.02) 10.02)

25

35

50

63

80

100

0.6

0.9

2.0

3.5

8.5

<0.51) 0.6

0.9

1.8

3.2

7.4

10.02) 10.02)

<0.51) <0.51) 0.8

1.6

10.02) 10.02) 10.02) 10.02) 10.02)

<0.51)

<0.51)

0.6

0.8

1.8

3.6

9.7

10.02) 10.02)

<0.51) <0.51) 0.6

0.7

1.5

2.7

7.3

10.02) 10.02)

13

<0.51)

20

10.02)

10

10.02)

DII-DIV gL/gG

0.5

0.8

1.6

2.6

5.2

8.3

10.02)

0.5

0.8

1.4

2.2

3.9

6.0

10.02)

<0.51)

0.6

1.4

2.4

5.5

10.02) 10.02)

<0.51) <0.51) 0.6

1.3

2.2

4.7

8.7

10.02)

1.3

2.0

3.6

5.4

10.02)

0.5

16

0.7

1.3

2.0

3.6

5.4

10.02)

0.6

1.2

1.9

3.2

4.6

8.4

<0.51)

0.5

<0.51)

20

1.2

1.8

3.1

4.4

7.8

10

25

1.2

1.8

3.0

4.2

7.3

13

1.3

1.9

3.3

5.0

9.4

1.7

2.8

3.9

6.8

16

1.2

1.8

3.2

4.4

8.0

40

2.7

3.8

6.5

20

1.2

1.8

3.1

4.1

7.0

50

2.5

3.5

5.7

25

1.7

2.8

3.8

6.5

5.3

32

2.7

3.7

6.2

3.5

5.9

32

63

40

0.6

50
63

Short circuit selectivity characteristic D towards fuse link DII-DIV*)

PL7

DII-DIV gL/gG

In [A]

10

16

<0.51)

<0.51)

20

1)
2)

25

35

50

63

80

100

10.02)

10.02)

0.6

1.0

2.8

5.8

10.02)

<0.51) 0.6

0.9

2.0

3.8

9.5

10.02) 10.02)

<0.51)

0.5

0.7

1.7

3.1

7.0

10.02) 10.02)

0.5

0.7

1.5

2.6

5.3

9.1

10.02)

<0.51)

0.7

1.4

2.2

3.9

6.0

10.02)

0.7

1.2

1.9

3.4

5.0

9.5

1.2

10
13

1.8

3.2

4.6

8.6

16

1.6

2.7

4.0

7.4

20

1.5

25
32
40

2.5

3.5

6.7

2.4

3.4

6.2

2.8

5.0
4.8

85

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

5.5

Protective Devices
Short Circuit Selectivity PL7 towards D01-D03 fuse link
In case of short circuit, there is selectivity between the miniature circuit breakers PL7 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link D01-D03*)

Short circuit selectivity characteristic C towards fuse link D01-D03*)

PL7

PL7

D01-D03 gL/gG

In [A]

10

20

25

35

<0.51) <0.51) 0.6

16

1.0

10.02) 10.02) 10.02) 10.02) 10.02)

50

63

80

100

<0.51) <0.51) 0.5

0.9

2.5

10.02) 10.02) 10.02) 10.02)


10.02)

D01-D03 gL/gG

In [A]

10

0.75

<0.51) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

16

20

25

35

50

63

80

100

1.0

<0.51) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.6

<0.51) 0.5

0.6

0.9

10.02) 10.02) 10.02) 10.02) 10.02)

<0.51)

0.5

0.8

1.7

4.0

7.0

10.02)

<0.51) 0.5

0.8

1.6

3.6

6.0

10.02) 10.02)

<0.51) <0.51) 0.5

0.7

10.02) 10.02) 10.02) 10.02) 10.02)

<0.51)

0.6

1.6

4.0

7.6

10.02) 10.02)

0.5

0.8

1.4

2.8

4.3

8.2

10.02)

10

0.5

0.7

1.3

2.4

3.4

6.0

10.02)

<0.51) <0.51) 0.5

1.3

3.1

5.7

10.02) 10.02)

13

<0.51)

<0.51)

1.2

2.7

4.5

10.02) 10.02)

<0.51) <0.51) <0.51) 1.2

2.5

4.0

8.6

10.02)

1.2

2.3

3.1

5.4

10.02)

16

0.7

1.2

2.3

3.2

5.3

10.02)

0.6

1.1

2.2

2.9

4.6

10.0

<0.51)

<0.51)

<0.51)

<0.51)

<0.51)

<0.51)

20

1.1

2.1

2.8

4.4

9.3

10

25

1.1

2.0

2.7

4.2

8.7

13

1.1

2.2

3.0

4.9

10.02)

2.0

2.6

4.0

8.0

16

1.1

2.1

2.8

4.4

9.5

40

2.5

3.8

7.5

20

1.0

2.0

2.6

4.0

8.3

50

2.3

3.4

6.7

25

1.9

2.5

3.8

7.8

6.2

32

2.5

3.7

7.3

3.5

7.0

32

63

40
50
63

Short circuit selectivity characteristic D towards fuse link D01-D03*)

PL7

D01-D03 gL/gG

In [A]

10

16

20

1)
2)

25

35

50

63

80

100
10.02)

<0.51)

0.7

1.7

4.6

7.7

10.02)

<0.51) <0.51) 0.6

1.5

3.5

5.8

10.02) 10.02)

0.5

<0.51)

0.5

1.3

2.9

4.5

9.0

10.02)

<0.51) 0.5

1.2

2.4

3.5

6.0

10.02)

0.5

1.1

2.2

3.0

5.0

10.02)

1.1

2.1

2.9

4.6

10.02)

16

1.9

2.6

3.9

9.0

20

1.7

2.3

3.5

8.0

2.2

3.4

7.5

2.9

6.0

10
13

25
32
40

5.7

86

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

6.5

Protective Devices
Short Circuit Selectivity PL7 towards NH-00 Fuses
In case of short circuit, there is selectivity between the miniature circuit breakers PL7 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link NH-00*)

Short circuit selectivity characteristic C towards fuse link NH-00*)

PL7

PL7

NH-00 gL/gG

In [A] 16

20

25

32

35

<0.51) 0.5

1.0

2.5

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

<0.51) <0.51) 0.8

1.3

2.3

<0.51)

0.7

1.1

1.6

2.2

3.6

4.8

8.9

10.02)

<0.51) <0.51) 0.7

1.1

1.5

2.0

3.3

4.3

7.6

10.02) 10.02) 10.02)

<0.51)

10.02)

10.02)

<0.51)

<0.51)

40

4.3

50

63

80

100 125 160

In [A] 16

10.02) 10.02) 10.02) 10.02) 10.02) 10.02)


10.02)

NH-00 gL/gG

10.02)

20

25

32

35

40

50

63

80

100 125 160

0.75

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.0

0.9

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

1.6

<0.51)

0.6

1.3

4.2

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

<0.51) 0.6

1.0

2.5

10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02) 10.02)

<0.51)

0.7

1.0

1.5

2.1

3.6

5.0

10.0

10.02) 10.02) 10.02)

0.6

1.0

1.3

1.7

2.6

3.3

5.2

10.02)

10

<0.51) 0.6

0.9

1.2

1.5

2.2

2.7

4.0

9.0

10.02) 10.02)

<0.51) <0.51) 0.6

0.8

1.2

1.7

2.8

3.8

8.7

10.02) 10.02) 10.02)

13

<0.51)

10.02)

<0.51)

0.5

0.8

1.2

1.5

2.5

3.3

5.7

10.02) 10.02) 10.02)

<0.51) <0.51) 0.5

0.8

1.1

1.5

2.3

2.9

4.9

10.02) 10.02) 10.02)

0.5

0.7

1.0

1.4

2.0

2.5

3.8

8.0

10.02) 10.02)

16

0.6

0.8

1.1

1.4

2.1

2.6

3.8

7.9

10.02)

0.5

0.7

1.0

1.3

1.9

2.4

3.4

6.4

9.3

10.02)

8
10

<0.51)

<0.51)

20

0.7

1.0

1.3

1.9

2.4

3.3

6.0

8.7

10.02)

25

0.7

1.0

1.3

1.8

2.3

3.2

5.7

8.0

10.02)

13

1.0

1.3

1.9

2.4

3.6

7.0

10.02) 10.02)

16

1.0

1.3

1.8

2.3

3.3

6.0

8.8

10.02)

1.0

1.2

1.7

2.2

3.2

5.5

7.7

10.02)

1.6

2.1

3.0

5.2

7.3

10.02)

2.1

2.9

5.0

7.0

10.02)

2.8

4.8

6.7

10.0

4.5

6.3

9.5

5.9

8.4

2.2

3.1

5.4

7.6

10.02)

40

2.1

3.0

5.1

7.2

10.02)

20

50

1.9

2.8

4.7

6.6

9.5

25

4.4

6.3

8.6

32

32

0.9

1.2

1.7

63

40
50
63

Short circuit selectivity characteristic D towards fuse link NH-00*)

PL7

1)

NH-00 gL/gG

In [A] 16

2)

20

25

32

35

40

50

63

80

100 125 160

<0.51)

0.7

1.0

1.6

2.2

3.8

5.2

10.0

10.02) 10.02) 10.02)

<0.51) 0.6

0.9

1.4

1.9

3.2

4.1

7.1

10.02) 10.02) 10.02)

<0.51)

0.5

0.8

1.2

1.6

2.6

3.3

5.5

10.02) 10.02) 10.02)

0.5

0.8

1.1

1.5

2.2

2.7

4.1

8.7

10.02) 10.02)

10

0.5

0.7

1.0

1.3

1.9

2.5

3.6

7.2

10.02) 10.02)

1.0

1.3

1.9

2.3

3.4

6.5

9.5

10.02)

1.1

1.6

2.0

3.0

5.5

8.0

10.02)

1.4

1.8

2.8

5.0

7.5

10.02)

1.8

2.7

4.8

7.0

10.02)

2.4

4.1

6.2

9.3

4.0

6.0

9.0

13
16
20
25
32
40

<0.51)

87

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

Protective Devices
Miniature Circuit Breakers PL6
High selectivity between MCB and back-up fuse due to low let-through
energy
Twin-purpose terminal (lift/open-mouthed) above and below
Busbar positioning optionally above or below
Meets the requirements of insulation co-ordination,
distance between contacts 4 mm, for secure isolation
Suitable for applications up to 48 V DC

Accessories:
Auxiliary switch for
subsequent installation

ZP-IHK
ZP-WHK

Tripping signal contact for


subsequent installation
Remote control and automatic switching device
Shunt trip release
Undervoltage release
Compact enclosure
Additional terminal 35mm2
Switching interlock

ZP-NHK
Z-FW/LP
ZP-ASA/..
Z-USA/..
KLV-TC-2
KLV-TC-4
Z-HA-EK/35
Z-IS/SPE-1TE

286052
286053
248437
248296
248438, 248439
248288-248291
276240
276241
263960
274418

Connection diagrams
1-pole

2-pole

3-pole

Technical Data
Electrical
Design according to
IEC/EN 60898-1
Current test marks as printed onto the device
Rated voltage
AC: 230/400V
DC: 48V (per pole,
max. 2 poles)
Rated frequency
50/60 Hz
Rated breaking capacity
IEC/EN 60898-1
6 kA
Characteristic
B, C, D
Back-up fuse
max. 100 A gL
Selectivity class
3
Rated peak withstand voltage Uimp
4 kV (1.2/50s)
Endurance
electrical comp.
4,000 operating cycles
mechanical comp.
20,000 operating cycles
Line voltage connection
optional (above/below)
Min. voltage
12 V AC/DC

Mechanical
Frame size
Device height
Device width
Mounting

Degree of protection
Upper and lower terminals
Terminal protection
Terminal capacity
Terminal fastening torque
Busbar thickness
Mounting

Dimensions (mm)

88

45 mm
80 mm
17.5 mm per pole (1MU)
quick fastening with
3 lock-in positions on
DIN rail IEC/EN 60715
IP20
open mouthed/lift terminals
finger and hand touch safe,
BGV A3, VE-EN 6
1-25 mm2
2-2.4 Nm
0.8 - 2 mm
independent of position

Protective Devices
Tripping Characteristics (IEC/EN 60898-1)

TRIPPING CURRENT

TRIPPING TIME
TRIPPING CURRENT

Seconds

Minutes

Minutes
TRIPPING TIME

Seconds

Seconds

TRIPPING TIME

Tripping characteristic D

Tripping characteristic C

Minutes

Tripping characteristic B

TRIPPING CURRENT

Quick-acting (B), slow (C), very slow (D)

Effect of the Ambient Temperature on Thermal Tripping Load Capacity of Series Connected Miniature Circuit
Breakers
Behaviour
Adjusted rated current values according to the ambient temperature

Load capacity factor KN

Ambient temperature T [C]

Number of devices (n) 1-pole

Effect of Power Frequency


Effect of power frequency on the tripping behaviour IMA of the quick release

IMA(f)/IMA(50Hz) [%]

Power frequency f [Hz]


50
60
100
162/3
91
100
101
106

200
115

300
134

400
141

89

Protective Devices
Let-through energy PL6, characteristic B, 1-pole

Let-through energy PL6, characteristic C, 1-pole

Let through energy I2t [A2 sec]

Let through energy I2t [A2 sec]

Let-through Energy PL6

Prospective short-circuit current [A]

Prospective short-circuit current [A]

Let through energy I2t [A2 sec]

Let-through energy PL6, characteristic D, 1-pole

Prospective short-circuit current [A]

90

Protective Devices
Short Circuit Selectivity PL6 towards DII-DIV fuse link
In case of short circuit, there is selectivity between the miniature circuit breakers PL6 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link DII-DIV*)

Short circuit selectivity characteristic C towards fuse link DII-DIV*)

PL6

DII-DIV gL/gG

PL6

In [A]

10

20

25

35

50

63

80

100

In [A]

10

20

25

35

50

63

80

100

<0.51) <0.51) 0.8

1.6

6.02)

6.02)

6.02)

6.02)

6.02)

<0.51) <0.51) 0.8

1.6

6.02)

6.02)

6.02)

6.02)

6.02)

<0.51) <0.51) 0.6

1.0

3.6

6.02)

6.02)

6.02)

6.02)

<0.51) <0.51) 0.6

0.8

1.8

3.6

6.02)

6.02)

6.02)

<0.51)

6.02)

6.02)

<0.51)

6.02)

6.02)

16

<0.51)

0.6

0.9

2.0

3.5

6.02)

<0.51) 0.6

0.9

1.8

3.2

6.02)

6.02)

6.02)

<0.51)

6.02)

10
13

0.6

0.7

1.5

2.7

<0.51) 0.5

0.6

1.4

2.4

5.5

6.02)

6.02)

<0.51)

6.02)

0.5

0.8

1.6

2.6

5.2

0.5

0.8

1.4

2.2

3.9

6.02)

6.02)

10

16

16

6.02)

6.02)

0.5

DII-DIV gL/gG

<0.51)

<0.51)

0.6

1.3

2.2

4.7

6.02)

<0.51) 0.6

1.3

2.0

3.6

6.02)

6.02)

13

1.3

1.9

3.3

5.0

6.02)

0.7

1.3

2.0

3.6

5.4

6.02)

0.6

1.2

1.9

3.2

4.6

6.02)

16

1.2

1.8

3.2

4.4

6.02)

20

1.2

1.8

3.1

4.1

6.02)

1.7

2.8

3.8

6.02)

2.7

3.7

6.02)

3.5

5.9

20

1.2

1.8

3.1

4.4

6.02)

25

1.2

1.8

3.0

4.2

6.02)

25

2.8

3.9

6.02)

32

40

2.7

3.8

6.02)

40

50

2.5

3.5

5.7

50

32

1.7

63

5.3

Short circuit selectivity characteristic D towards fuse link DII-DIV*)

PL6

DII-DIV gL/gG

In [A]

10

16

<0.51)

<0.51)

20

1)
2)

25

35

50

63

80

100

6.02)

6.02)

0.6

1.0

2.8

5.8

6.02)

<0.51) 0.6

0.9

2.0

3.8

6.02)

6.02)

6.02)

<0.51)

6.02)

6.02)

0.5

0.7

1.7

3.1

6.02)

0.5

0.7

1.5

2.6

5.3

6.02)

6.02)

<0.51)

6.02)

0.7

1.4

2.2

3.9

6.02)

0.7

1.2

1.9

3.4

5.0

6.02)

1.2

1.8

3.2

4.6

6.02)

16

1.6

2.7

4.0

6.02)

20

1.5

2.5

3.5

6.02)

2.4

3.4

6.02)

2.8

5.0

10
13

25
32
40

4.8

91

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

5.5

Protective Devices
Short Circuit Selectivity PL6 towards D01-D03 fuse link
In case of short circuit, there is selectivity between the miniature circuit breakers PL6 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link D01-D03*)

Short circuit selectivity characteristic C towards fuse link D01-D03*)

PL6

PL6

D01-D03 gL/gG
16

D01-D03 gL/gG

In [A]

10

20

25

35

50

63

80

100

In [A]

10

20

25

35

50

63

80

100

<0.51) <0.51) 0.6

1.0

6.02)

6.02)

6.02)

6.02)

6.02)

<0.51) <0.51) 0.5

16

0.7

6.02)

6.02)

6.02)

6.02)

6.02)

<0.51) <0.51) 0.5

0.9

2.5

6.02)

6.02)

6.02)

6.02)

<0.51) <0.51) <0.51) 0.6

1.6

4.0

6.02)

6.02)

6.02)

6.02)

6.02)

<0.51)

1.3

3.1

5.7

6.02)

6.02)

2.7

4.5

6.02)

6.02)
6.02)

<0.51)

0.5

0.8

1.7

4.0

6.02)

<0.51) 0.5

0.8

1.6

3.6

6.02)

6.02)

6.02)

<0.51) <0.51) <0.51) 1.2

6.02)

<0.51)

0.5

0.8

1.4

2.8

4.3

6.02)

10

0.5

0.7

1.3

2.4

3.4

6.02)

6.02)

13

<0.51)

16

<0.51)

<0.51)

0.5

<0.51)

1.2

2.5

4.0

6.02)

10

<0.51) <0.51) 1.2

2.3

3.1

5.4

6.02)

13

1.1

2.2

3.0

4.9

6.02)

0.7

1.2

2.3

3.2

5.3

6.02)

0.6

1.1

2.2

2.9

4.6

6.02)

16

1.1

2.1

2.8

4.4

6.02)

20

1.0

2.0

2.6

4.0

6.02)

1.9

2.5

3.8

6.02)

2.5

3.7

6.02)

3.5

6.02)

20

1.1

2.1

2.8

4.4

6.02)

25

1.1

2.0

2.7

4.2

6.02)

25

2.6

4.0

6.02)

32

2.5

3.8

6.02)

40

3.4

6.02)

50

32

2.0

40
50

2.3

6.02)

63

Short circuit selectivity characteristic D towards fuse link D01-D03*)

PL6

D01-D03 gL/gG

In [A]

10

16

<0.51)

<0.51)

20

1)
2)

25

35

50

63

80

100

6.02)

6.02)

6.02)

6.02)

6.02)

6.02)
6.02)

0.6

0.8

2.2

6.02)

<0.51) 0.5

0.7

1.7

4.6

<0.51)

<0.51)

0.6

1.5

3.5

5.8

6.02)

<0.51) 0.5

1.3

2.9

4.5

6.02)

6.02)

<0.51)

6.02)

0.5

1.2

2.4

3.5

6.02)

0.5

1.1

2.2

3.0

5.0

6.02)

1.1

2.1

2.9

4.6

6.02)

16

1.9

2.6

3.9

6.02)

20

1.7

2.3

3.5

6.02)

2.2

3.4

6.02)

2.9

6.02)

10
13

25
32
40

5.7

92

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

6.02)

Protective Devices
Short Circuit Selectivity PL6 towards NH-00 Fuses
In case of short circuit, there is selectivity between the miniature circuit breakers PL6 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
*) basically in accordance with EN 60898-1 D.5.2.b

Short circuit selectivity characteristic B towards fuse link NH-00*)

Short circuit selectivity characteristic C towards fuse link NH-00*)

PL6

PL6

NH-00 gL/gG

In [A] 16

20

25

32

35

20

25

32

35

<0.51) 0.5

1.0

2.5

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

<0.51) 0.6

1.0

2.5

6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

<0.51) <0.51) 0.8

1.3

2.3

6.02) 6.02) 6.02) 6.02) 6.02) 6.02)

<0.51)

0.7

1.1

1.6

2.2

3.6

<0.51) <0.51) 0.7

1.1

1.5

2.0

3.3

<0.51)

<0.51)

<0.51)

40

4.3

50

63

80

100 125 160

NH-00 gL/gG

In [A] 16

40

50

63

80

100 125 160

<0.51) <0.51) 0.7

1.0

1.5

2.1

3.6

5.0

6.02) 6.02) 6.02) 6.02)

4.8

6.02)

6.02)

<0.51)

0.6

0.8

1.2

1.7

2.8

3.8

6.02) 6.02) 6.02) 6.02)

4.3

6.02) 6.02) 6.02) 6.02)

<0.51) <0.51) 0.5

0.8

1.2

1.5

2.5

3.3

5.7

6.02) 6.02) 6.02)

<0.51)

0.5

0.8

1.1

1.5

2.3

2.9

4.9

6.02) 6.02) 6.02)

0.5

0.7

1.0

1.4

2.0

2.5

3.8

6.02) 6.02) 6.02)

6.02)

6.02)

0.6

1.0

1.3

1.7

2.6

3.3

5.2

6.02)

10

<0.51) 0.6

0.9

1.2

1.5

2.2

2.7

4.0

6.02) 6.02) 6.02)

10

13

<0.51)

6.02)

13

1.0

1.3

1.9

2.4

3.6

6.02) 6.02) 6.02)

16

6.02)

6.02)

6.02)

<0.51)

<0.51)

0.6

0.8

1.1

1.4

2.1

2.6

3.8

6.02)

0.5

0.7

1.0

1.3

1.9

2.4

3.4

6.02) 6.02) 6.02)

16

1.0

1.3

1.8

2.3

3.3

6.02) 6.02) 6.02)

6.02)

6.02)

20

1.0

1.2

1.7

2.2

3.2

5.5

6.02) 6.02)

1.6

2.1

3.0

5.2

6.02) 6.02)

2.1

2.9

5.0

6.02) 6.02)

2.8

4.8

6.02) 6.02)

4.5

6.02) 6.02)

20

0.7

1.0

1.3

1.9

2.4

3.3

6.02)

25

0.7

1.0

1.3

1.8

2.3

3.2

5.7

6.02) 6.02)

25

6.02)

32

32

0.9

1.2

1.7

40
50

2.2

3.1

5.4

6.02)

2.1

3.0

5.1

6.02) 6.02)

40

4.7

6.02)

6.02)

50

4.4

6.02) 6.02)

63

1.9

2.8

63

5.9

Short circuit selectivity characteristic D towards fuse link NH-00*)

PL6

1)

NH-00 gL/gG

In [A] 16

20
<0.51)

25

2)

32

35

40

50

63

80

100 125 160

6.02)

6.02)

6.02) 6.02) 6.02)

<0.51)

0.8

1.3

2.1

3.1

6.02)

<0.51) <0.51) 0.7

1.0

1.6

2.2

3.8

5.2

6.02) 6.02) 6.02) 6.02)

<0.51)

0.6

0.9

1.4

1.9

3.2

4.1

6.02) 6.02) 6.02) 6.02)

<0.51) 0.5

0.8

1.2

1.6

2.6

3.3

5.5

6.02) 6.02) 6.02)

0.5

0.8

1.1

1.5

2.2

2.7

4.1

6.02) 6.02) 6.02)

10

0.5

0.7

1.0

1.3

1.9

2.5

3.6

6.02) 6.02) 6.02)

1.0

1.3

1.9

2.3

3.4

6.02) 6.02) 6.02)

1.1

1.6

2.0

3.0

5.5

6.02) 6.02)

1.4

1.8

2.8

5.0

6.02) 6.02)

1.8

2.7

4.8

6.02) 6.02)

2.4

4.1

6.02) 6.02)

4.0

6.02) 6.02)

13
16
20
25
32
40

93

Selectivity limit current Is under 0.5 kA


Selectivity limit current Is = rated breaking capacity Icn of the MCB
no selectivity

6.02)

Protective Devices
Miniature Circuit Breakers PL7-DC
High selectivity between MCB and back-up fuse due to low let-through
energy
Compatible with standard busbar
Twin-purpose terminal (lift/open-mouthed) above and below
Busbar positioning optionally above or below
Meets the requirements of insulation co-ordination,
distance between contacts 4 mm, for secure isolation
Rated breaking capacity 10 kA according to IEC/EN 60947-2
Rated voltage up to 250 V (per pole), = 4 ms
Take into account polarity!

Accessories:
Auxiliary switch for
subsequent installation
Tripping signal contact for
subsequent installation
Remote control and automatic switching device
Shunt trip release
Undervoltage release
Compact enclosure
Additional terminal 35mm2
Switching interlock

ZP-IHK
ZP-NHK
Z-FW/LP
ZP-ASA/..
Z-USA/..
KLV-TC-2
KLV-TC-4
Z-HA-EK/35
Z-IS/SPE-1TE

286052
248437
248296
248438, 248439
248288-248291
276240
276241
263960
274418

Connection diagrams
1-pole

2-pole

Technical Data
Electrical
Design according to
IEC/EN 60947-2
Current test marks as printed onto the device
Rated voltage
DC
1-2 A type: 220V (per pole)
3-50 A types: 250V (per pole)
Rated breaking capacity
according to IEC/EN 60947-2
10 kA
Characteristic
C
Back-up fuse
max. 100 A gL
Selectivity class
3
Rated peak withstand voltage Uimp
4 kV (1.2/50s)
Endurance
electrical comp.
4,000 operating cycles
mechanical comp.
20,000 operating cycles
Line voltage connection
optional (above/below)

Mechanical
Frame size
Device height
Device width
Mounting

Degree of protection
Upper and lower terminals
Terminal protection
Terminal capacity
Terminal fastening torque
Busbar thickness
Mounting

Note: not for PV string protection!

Dimensions (mm)
1P

2P

Connection examples
Connection example at 250V=, 1-pole

Connection example at 500V=, 2-pole

94

45 mm
80 mm
17.5 mm per pole (1MU)
quick fastening with
3 lock-in positions on
DIN rail IEC/EN 60715
IP20
open mouthed/lift terminals
finger and hand touch safe,
BGV A3, VE-EN 6
1-25 mm2
2-2.4 Nm
0.8 - 2 mm
independent of position

Protective Devices
Tripping characteristic PL7-DC

Let-through Energy PL7-DC

Type C

Type C, 250 V d.c., = 5 ms (acc. to IEC/EN 60947-2)

95

Protective Devices
Miniature Circuit Breakers PL4
High selectivity between MCB and back-up fuse due to low let-through
energy
Twin-purpose terminal (lift/open-mouthed) above and below
Busbar positioning optionally above or below
Meets the requirements of insulation co-ordination,
distance between contacts 4 mm, for secure isolation
Suitable for applications up to 48 V DC

Accessories:
Auxiliary switch for
subsequent installation

ZP-IHK
ZP-WHK

Tripping signal contact for


subsequent installation
Remote control and automatic switching device
Shunt trip release
Undervoltage release
Compact enclosure
Additional terminal 35mm2
Switching interlock

ZP-NHK
Z-FW/LP
ZP-ASA/..
Z-USA/..
KLV-TC-2
KLV-TC-4
Z-HA-EK/35
Z-IS/SPE-1TE

286052
286053
248437
248296
248438, 248439
248288-248291
276240
276241
263960
274418

Connection diagrams
1-pole

2-pole

3-pole

Technical Data
Electrical
Design according to
IEC/EN 60898-1
Current test marks as printed onto the device
Rated voltage
AC: 230/400V
DC: 48V (per pole,
max. 2 poles)
Rated frequency
50/60 Hz
Rated breaking capacity
IEC/EN 60898-1
4.5 kA
Characteristic
B, C, D
Back-up fuse
max. 100 A gL
Selectivity class
3
Rated peak withstand voltage Uimp
4 kV (1.2/50s)
Endurance
electrical comp.
4,000 operating cycles
mechanical comp.
20,000 operating cycles
Line voltage connection
optional (above/below)
Min. voltage
12 V AC/DC

Mechanical
Frame size
Device height
Device width
Mounting

Degree of protection
Upper and lower terminals
Terminal protection
Terminal capacity
Terminal fastening torque
Busbar thickness
Mounting

Dimensions (mm)

96

45 mm
80 mm
17.5 mm per pole (1MU)
quick fastening with
3 lock-in positions on
DIN rail IEC/EN 60715
IP20
open mouthed/lift terminals
finger and hand touch safe,
BGV A3, VE-EN 6
1-25 mm2
2-2.4 Nm
0.8 - 2 mm
independent of position

Protective Devices
Let-through energy PL4, characteristic B, 1-pole

Let-through energy PL4, characteristic C, 1-pole

Let through energy I2t [A2 sec]

Let through energy I2t [A2 sec]

Let-through Energy PL4

Prospective short-circuit current [A]

Prospective short-circuit current [A]

Short Circuit Selectivity PL4 towards DII-DIV fuse link


In case of short circuit, there is selectivity between the miniature circuit breakers PL4 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
1) Selectivity limit current I under 0.5 kA
*) basically in accordance with EN 60898-1 D.5.2.b
s
2)

Selectivity limit current Is = rated breaking capacity Icn of the MCB


no selectivity

Short circuit selectivity characteristic B towards fuse link DII-DIV*)

Short circuit selectivity characteristic C towards fuse link DII-DIV*)

PL4

PL4

DII-DIV gL/gG
16

DII-DIV gL/gG

In [A]

10

20

25

35

50

63

80

100

In [A]

10

16

20

25

35

50

63

80

100

1.0

<0.51) 1.2

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

0.75

1.0

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

<0.51) 1.0

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.0

<0.51) 1.2

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51) <0.51) 0.8

1.6

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

<0.51) <0.51) 1.0

2.2

4.52)

4.52)

4.52)

4.52)

4.52)

2.5

<0.51)

0.8

1.5

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51)

0.8

1.6

4.52)

4.52)

4.52)

4.52)

4.52)

3.0

<0.51) <0.51) 0.8

1.4

4.52)

4.52)

4.52)

4.52)

4.52)

2.5

<0.51) <0.51) 0.8

1.4

4.52)

4.52)

4.52)

4.52)

4.52)

3.5

<0.51)

0.7

1.3

4.52)

4.52)

4.52)

4.52)

4.52)

3.0

<0.51)

0.8

0.9

4.52)

4.52)

4.52)

4.52)

4.52)

<0.51) <0.51) 0.6

1.0

3.6

4.52)

4.52)

4.52)

4.52)

3.5

<0.51) <0.51) 0.6

0.9

2.2

4.52)

4.52)

4.52)

4.52)

<0.51)

4.52)

4.52)

<0.51)

0.6

0.8

1.8

3.6

4.52)

4.52)

4.52)

<0.51) <0.51) 0.6

0.7

1.5

2.7

4.52)

4.52)

4.52)

4.52)

4.52)

<0.51)

<0.51)

<0.51)

0.6

0.9

2.0

3.5

4.52)

<0.51) 0.6

0.9

1.8

3.2

4.52)

4.52)

4.52)

<0.51)

4.52)

4.52)

<0.51)

0.6

1.4

2.4

4.52)

<0.51) <0.51) 0.6

1.3

2.2

4.52)

4.52)

4.52)
4.52)

10
13
16

<0.51)

<0.51)

0.5

0.8

1.6

2.6

4.52)

0.5

0.8

1.4

2.2

3.9

4.52)

4.52)
4.52)

10

0.5

0.7

1.3

2.0

3.6

4.52)

0.6

1.2

1.9

3.2

4.52)

4.52)

1.3

2.0

3.6

13

1.3

1.9

3.3

4.52)

4.52)

16

1.2

1.8

3.2

4.4

4.52)

1.2

1.8

3.1

4.1

4.52)

1.7

2.8

3.8

4.52)

2.7

3.7

4.52)

3.5

4.52)

20

1.2

1.8

3.1

4.4

25

1.2

1.8

3.0

4.2

4.52)

20

2.8

3.9

4.52)

25

2.7

3.8

4.52)

32

3.5

4.52)

40

4.52)

50

40
50
63

1.7

2.5

63

97

0.5

4.52)

4.52)

32

<0.51)

<0.51)

0.6

4.52)

Protective Devices
In case of short circuit, there is selectivity between the miniature circuit breakers PL4 and the upstream fuses up to the specified values of the selectivity limit
current Is [kA] (i. e. in case of short-circuit currents Iks under Is, only the MCB will trip, in case of short circuit currents above this value both protective devices
will respond).
1) Selectivity limit current I under 0.5 kA
s
*) basically in accordance with EN 60898-1 D.5.2.b
2) Selectivity limit current I = rated breaking capacity I of the MCB
s
cn
no selectivity

Short Circuit Selectivity PL4 towards D01-D03 fuse link


Short circuit selectivity characteristic B towards fuse link D01-D03*)

Short circuit selectivity characteristic C towards fuse link D01-D03*)

PL4

D01-D03 gL/gG

PL4

D01-D03 gL/gG

In [A]

10

16

20

25

35

50

63

80

100

In [A]

10

16

20

25

35

50

63

80

100

1.0

<0.51)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

0.75

<0.51)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

<0.51) 4.1

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.0

<0.51) 4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51)

0.6

1.0

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

<0.51)

0.6

0.9

4.52)

4.52)

4.52)

4.52)

4.52)

2.5

<0.51) <0.51) 0.6

1.0

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51) <0.51) 0.5

0.7

4.52)

4.52)

4.52)

4.52)

4.52)

3.0

<0.51)

0.5

1.0

4.52)

4.52)

4.52)

4.52)

4.52)

2.5

<0.51)

0.7

4.52)

4.52)

4.52)

4.52)

4.52)

3.5

<0.51) <0.51) 0.5

0.9

4.52)

4.52)

4.52)

4.52)

4.52)

3.0

<0.51) <0.51) <0.51) 0.6

1.9

4.52)

4.52)

4.52)

4.52)

<0.51)

4.52)

4.52)

4.52)

3.5

<0.51)

0.6

1.8

4.52)

4.52)

4.52)

4.52)

<0.51) <0.51) <0.51) 0.6

1.6

4.0

4.52)

4.52)

4.52)

4.52)

4.52)

<0.51)

<0.51)

<0.51)

0.5

<0.51)

0.5

0.9

2.5

4.52)

<0.51) 0.5

0.8

1.7

4.0

4.52)

4.52)

4.52)

<0.51)

4.52)

4.52)

<0.51)

1.3

3.1

4.52)

2.7

4.52)

4.52)

4.52)
4.52)

<0.51)

0.5

<0.51)

0.5

0.8

1.6

3.6

4.52)

<0.51)

0.5

0.8

1.4

2.8

4.3

4.52)

4.52)

<0.51) <0.51) <0.51) 1.2

4.52)

<0.51)

10

10

0.5

0.7

1.3

2.4

3.4

4.52)

13

<0.51) 0.7

1.2

2.3

3.2

4.52)

4.52)
4.52)

13

1.1

16

0.6

20
25

<0.51)

0.5

<0.51)

1.2

2.5

4.0

4.52)

<0.51) <0.51) 1.2

2.3

3.1

4.52)

4.52)

2.2

3.0

4.52)

4.52)

1.1

2.2

2.9

4.52)

1.1

2.1

2.8

4.4

4.52)

16

1.1

2.1

2.8

4.4

4.52)

20

1.0

2.0

2.6

4.0

4.52)

1.9

2.5

3.8

4.52)

2.5

3.7

4.52)

3.5

4.52)

1.1

32

2.0

2.7

4.2

4.52)

2.0

2.6

4.0

4.52)

25
32

40

2.5

3.8

4.52)

50

2.3

3.4

4.52)

40

4.52)

50

63

4.52)

63

Short Circuit Selectivity PL4 towards NH-00 fuse link


Short circuit selectivity characteristic B towards fuse link NH-00*)

Short circuit selectivity characteristic C towards fuse link NH-00*)

PL4

PL4

NH-00 gL/gG

In [A] 16

20

25

32

35

40

50

63

80

100 125 160

1.0

0.9

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

1.5

0.8

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

2.0

<0.51)

0.5

1.0

2.5

<0.51) 0.5

1.0

3.0

<0.51)

0.5

3.5

<0.51) 0.5

<0.51)

0.8

1.3

2.3

<0.51) <0.51) 0.7

1.1

1.6

<0.51)

0.7

1.1

1.5

2.0

3.3

<0.51) <0.51) 0.6

1.0

1.3

1.7

2.6

<0.51)

<0.51)

4.52)

NH-00 gL/gG

In [A] 16

4.52)

20

25

32

35

40

50

63

80

100 125 160

0.75

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52) 4.52) 4.52)

1.0

0.9

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

2.5

4.52)

4.52)

1.5

<0.51)

0.6

1.3

4.2

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

2.3

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

0.9
0.9

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

2.0

<0.51) 0.6

1.0

2.5

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

2.1

4.52)

4.52)

2.5

<0.51)

1.0

2.1

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

1.8

4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

3.0

<0.51) <0.51) 0.7

1.2

1.8

2.6

4.52) 4.52) 4.52) 4.52) 4.52) 4.52)

3.5

<0.51)

0.7

1.1

1.7

2.4

4.2

4.52) 4.52) 4.52) 4.52) 4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.52)

4.3

4.52)

4.52)

4.52)

4.52)

2.2

3.6

4.52) 4.52) 4.52) 4.52) 4.52)

0.5

<0.51)

<0.51) <0.51) 0.7

1.0

1.5

2.1

3.6

4.52) 4.52) 4.52) 4.52) 4.52)

4.3

4.52)

4.52)

<0.51)

0.6

0.8

1.2

1.7

2.8

3.8

4.52) 4.52) 4.52) 4.52)

3.3

4.52) 4.52) 4.52) 4.52)

<0.51) <0.51) 0.5

0.8

1.2

1.5

2.5

3.3

4.52) 4.52) 4.52) 4.52)

<0.51)

0.5

0.8

1.1

1.5

2.3

2.9

4.52) 4.52) 4.52) 4.52)

0.5

0.7

1.0

1.4

2.0

2.5

3.8

4.52) 4.52) 4.52)

4.52)

4.52)

10

<0.51)

0.6

0.9

1.2

1.5

2.2

2.7

4.0

4.52)

13

<0.51) 0.6

0.8

1.1

1.4

2.1

2.6

3.8

4.52) 4.52) 4.52)

10

4.52)

13

1.0

1.3

1.9

2.4

3.6

4.52) 4.52) 4.52)

16
20
25
32

0.5

4.52)

<0.51)

0.7

1.0

1.3

1.9

2.4

3.4

4.52)

0.7

1.0

1.3

1.9

2.4

3.3

4.52) 4.52) 4.52)

16

1.0

1.3

1.8

2.3

3.3

4.52) 4.52) 4.52)

4.52)

20

1.0

1.2

1.7

2.2

3.2

4.52) 4.52) 4.52)

1.6

2.1

3.0

4.52) 4.52) 4.52)

2.1

2.9

4.52) 4.52) 4.52)

2.8

4.52) 4.52) 4.52)

0.7

4.52)

4.52)

<0.51)

1.0

1.3

1.8

2.3

3.2

4.52)

4.52)

0.9

1.2

1.7

2.2

3.1

4.52) 4.52) 4.52)

25

4.52)

32

40

2.1

3.0

4.52)

50

1.9

2.8

4.52) 4.52) 4.52)

40

4.52)

50

4.52) 4.52) 4.52)

63

4.52) 4.52)

63

4.4

4.52)

4.52)

98

Protective Devices
Miniature Circuit Breakers PL6-DC
High selectivity between MCB and back-up fuse due to low let-through
energy
Compatible with standard busbar
Twin-purpose terminal (lift/open-mouthed) above and below
Busbar positioning optionally above or below
Meets the requirements of insulation co-ordination,
distance between contacts 4 mm, for secure isolation
Rated breaking capacity 10 kA according to IEC/EN 60947-2
Rated voltage up to 250 V (per pole), = 4 ms
Take into account polarity!

Accessories:
Auxiliary switch for
subsequent installation
Tripping signal contact for
subsequent installation
Remote control and automatic switching device
Shunt trip release
Undervoltage release
Compact enclosure
Additional terminal 35mm2
Switching interlock

ZP-IHK
ZP-NHK
Z-FW/LP
ZP-ASA/..
Z-USA/..
KLV-TC-2
KLV-TC-4
Z-HA-EK/35
Z-IS/SPE-1TE

286052
248437
248296
248438, 248439
248288-248291
276240
276241
263960
274418

Connection diagrams
1-pole

2-pole

Technical Data
Electrical
Design according to
IEC/EN 60947-2
Current test marks as printed onto the device
Rated voltage
DC
1-2 A type: 220V (per pole)
3-50 A types: 250V (per pole)
Rated breaking capacity
according to IEC/EN 60947-2
6 kA
Characteristic
C
Back-up fuse
max. 100 A gL
Selectivity class
3
Rated peak withstand voltage Uimp
4 kV (1.2/50s)
Endurance
electrical comp.
4,000 operating cycles
mechanical comp.
20,000 operating cycles
Line voltage connection
optional (above/below)

Mechanical
Frame size
Device height
Device width
Mounting

Degree of protection
Upper and lower terminals
Terminal protection
Terminal capacity
Terminal fastening torque
Busbar thickness
Mounting

Note: not for PV string protection!

Dimensions (mm)
1P

2P

Connection examples
Connection example at 250V=, 1-pole

Connection example at 500V=, 2-pole

99

45 mm
80 mm
17.5 mm per pole (1MU)
quick fastening with
3 lock-in positions on
DIN rail IEC/EN 60715
IP20
open mouthed/lift terminals
finger and hand touch safe,
BGV A3, VE-EN 6
1-25 mm2
2-2.4 Nm
0.8 - 2 mm
independent of position

Protective Devices
Tripping characteristic PL6-DC

Let-through Energy PL6-DC

Type C

Type C, 250 V d.c., = 5 ms (acc. to IEC/EN 60947-2)

100