Sei sulla pagina 1di 20

NOKIA XL Project

RET Antenna Mapping

25 July 2022

Confidential Nokia and XL Axiata


LADDER 2
Kathrein 84510866

Y1 Y2 must be used for 4T4R

Antenna Type ALD RETU ALD productCode ALD serialNumber antModel sectorID
Kathrein 84510866 1 1 32866 XXXXX-R1 84510866_R1 RET_900_X
Kathrein 84510866 2 1 32866 XXXXX-Y1 84510866_Y1 RET_1800-2100_X-A
Kathrein 84510866 3 1 32866 XXXXX-Y2 84510866_Y2 RET_1800-2100_X-B
Commscope 6P-2L4M-D3

Y1 Y2 must be used for 4T4R

Ladder Antenna Type Variant ALD RETU ALD productCode ALD serialNumber antModel sectorID
Ladder 2 Commscope 6P-2L4M-D3 1 1 COMMRET2S CNXXXXXR1 6P-2L4M-D3 RET_900_X
Ladder 2 Commscope 6P-2L4M-D3 2 1 COMMRET2S CNXXXXXY1 6P-2L4M-D3 RET_1800-2100_X-A
Ladder 2 Commscope 6P-2L4M-D3 3 1 COMMRET2S CNXXXXXY2 6P-2L4M-D3 RET_1800-2100_X-B
Commscope RVV-45A-R3

Y1 Y2 must be used for 4T4R

Ladder Antenna Type Variant ALD RETU ALD productCode ALD serialNumber antModel sectorID
Ladder 2 Commscope RVV-45A-R3 1 1 RVV-45A-R3 CNXXXXX1 RVV-45A-R3 RET_900_X
Ladder 2 Commscope RVV-45A-R3 2 1 RVV-45A-R3 CNXXXXX2 RVV-45A-R3 RET_1800-2100_X-A
Ladder 2 Commscope RVV-45A-R3 3 1 RVV-45A-R3 CNXXXXX3 RVV-45A-R3 RET_1800-2100_X-B
Rosenberger MB-G7W92U9X65V-00 Hybrid

Y1 Y2 must be used for 4T4R


Y3 Y4 unused. It’s for Twin Beam 2T2R

Ladder Antenna Type Variant ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Ladder 2 Rosenberger MB-G7W92U9X65V-00 1 1 1 ICU-005 XXXXX-MM 649064-R1 RET_900_X
Ladder 2 Rosenberger MB-G7W92U9X65V-00 1 1 2 ICU-005 XXXXX-MM 649064-Y1 RET_1800-2100_X-A
Ladder 2 Rosenberger MB-G7W92U9X65V-00 1 1 3 ICU-005 XXXXX-MM 649064-Y2 RET_1800-2100_X-B
Ladder 2 Rosenberger MB-G7W92U9X65V-00 1 1 4 ICU-005 XXXXX-MM 649064-Y3 RET_unused_X-A Y3 Used for Twin Beam
Ladder 2 Rosenberger MB-G7W92U9X65V-00 1 1 5 ICU-005 XXXXX-MM 649064-Y4 RET_unused_X-B Y4 Used for Twin Beam
Ladder 2 Rosenberger MB-G7W92U9X65V-00 2 1 1 ICU-005 XXXXX-Y3 649064-Y3 RET_unused_X-A Y3 Used for Twin Beam
Ladder 2 Rosenberger MB-G7W92U9X65V-00 2 2 1 ICU-005 XXXXX-Y1 649064-Y1 RET_1800-2100_X-A
Ladder 2 Rosenberger MB-G7W92U9X65V-00 2 3 1 ICU-005 XXXXX-R1 649064-R1 RET_900_X
Ladder 2 Rosenberger MB-G7W92U9X65V-00 2 4 1 ICU-005 XXXXX-Y2 649064-Y2 RET_1800-2100_X-B
Ladder 2 Rosenberger MB-G7W92U9X65V-00 2 5 1 ICU-005 XXXXX-Y4 649064-Y4 RET_unused_X-B Y4 Used for Twin Beam
Ladder 2 Rosenberger MB-G7W92U9X65V-00 3 1 1 ICU-005 XXXXX-Y3 661308-Y3 RET_unused_X-A Y3 Used for Twin Beam
Ladder 2 Rosenberger MB-G7W92U9X65V-00 3 2 1 ICU-005 XXXXX-Y1 661308-Y1 RET_1800-2100_X-A
Ladder 2 Rosenberger MB-G7W92U9X65V-00 3 3 1 ICU-005 XXXXX-R1 661308-R1 RET_900_X
Ladder 2 Rosenberger MB-G7W92U9X65V-00 3 4 1 ICU-005 XXXXX-Y2 661308-Y2 RET_1800-2100_X-B
Ladder 2 Rosenberger MB-G7W92U9X65V-00 3 5 1 ICU-005 XXXXX-Y4 661308-Y4 RET_unused_X-B Y4 Used for Twin Beam
Ladder 2 Rosenberger MB-G7W92U9X65V-00 4 1 1 SCU-002 XXXXX-R1 669125-R1 RET_900_X
Ladder 2 Rosenberger MB-G7W92U9X65V-00 4 1 2 SCU-002 XXXXX-Y3 669125-Y3 RET_unused_X-A Y3 Used for Twin Beam
Ladder 2 Rosenberger MB-G7W92U9X65V-00 4 1 3 SCU-002 XXXXX-Y1 669125-Y1 RET_1800-2100_X-A
Ladder 2 Rosenberger MB-G7W92U9X65V-00 4 1 4 SCU-002 XXXXX-Y2 669125-Y2 RET_1800-2100_X-B
Ladder 2 Rosenberger MB-G7W92U9X65V-00 4 1 5 SCU-002 XXXXX-Y4 669125-Y4 RET_unused_X-B Y4 Used for Twin Beam
Rosenberger BA-G7W8W8W8X65V-10

Mostly Y1 Y2 are used but some sites are used Y1 Y3 or Y2 Y3


RET mapping need to inline with actual port. Actual Connection check is
needed.
For preventive, Y1, Y2, Y3 Tilt should be set as same value.

Ladder Antenna Type Variant ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 1 1 1 ICU-005 XXXXX-MM 653561-R1 RET_900_X
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 1 1 2 ICU-005 XXXXX-MM 653561-Y1 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 1 1 3 ICU-005 XXXXX-MM 653561-Y2 RET_1800-2100_X-B/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 1 1 4 ICU-005 XXXXX-MM 653561-Y3 RET_1800-2100_X-B/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 2 1 1 ICU-005 XXXXX-Y3 653561-Y3 RET_1800-2100_X-B/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 2 2 1 ICU-005 XXXXX-Y1 653561-Y1 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 2 3 1 ICU-005 XXXXX-R1 653561-R1 RET_900_X
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 2 4 1 ICU-005 XXXXX-Y2 653561-Y2 RET_1800-2100_X-B/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 3 1 1 ICU-005 XXXXX-Y3 660790-Y3 RET_1800-2100_X-B/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 3 2 1 ICU-005 XXXXX-Y1 660790-Y1 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 3 3 1 ICU-005 XXXXX-R1 660790-R1 RET_900_X
Ladder 2 Rosenberger BA-G7W8W8W8X65V-10 3 4 1 ICU-005 XXXXX-Y2 660790-Y2 RET_1800-2100_X-B/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Rosenberger BA-G7W9W9X65V

Ladder Antenna Type Variant ALD RETU ALD productCode ALD serialNumber antModel sectorID
Ladder 2 Rosenberger BA-G7W9W9X65V-11 1 1 ECU-003/ECU-003N XXXXX-MM 663418-Y1 RET_1800-2100_X-A
Ladder 2 Rosenberger BA-G7W9W9X65V-11 1 2 ECU-003/ECU-003N XXXXX-MM 663418-R1 RET_900_X
Ladder 2 Rosenberger BA-G7W9W9X65V-11 1 3 ECU-003/ECU-003N XXXXX-MM 663418-Y2 RET_1800-2100_X-B
Comba ODI-065R17M18JJJ-G

Mostly Y1 Y2 are used.


RET mapping need to inline with actual port. Actual
Connection check is needed.
For preventive, Y1, Y2, Y3 Tilt should be set as same value.
Antenna Type ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Comba ODI-065R17M18JJJ-G 1 1 IRCU-502 XXXXX-Y3 17M18JJJ-HMBL RET_unused_X HMBL=Y3
Comba ODI-065R17M18JJJ-G 2 1 IRCU-502 XXXXX-Y1 17M18JJJ-HMBR RET_1800-2100_X-A HMBR=Y1
Comba ODI-065R17M18JJJ-G 3 1 IRCU-502 XXXXX-Y2 17M18JJJ-HMTL RET_1800-2100_X-B HMTL=Y2
Comba ODI-065R17M18JJJ-G 4 1 IRCU-502 XXXXX-R1 17M18JJJ-LMC RET_900_X LMC=R1
Kathrein 80010892V01

Mostly Y1 Y2 are used.


RET mapping need to inline with actual port. Actual Connection check is needed.
For preventive, Y1, Y2, Y3, Y4 Tilt should be set as same value.

Antenna Type ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Kathrein 80010892V01 1 1 86010153V01 XXXXX-R1 80010892V01_R1 RET_900_X
Kathrein 80010892V01 2 1 86010153V01 XXXXX-Y1 80010892V01_Y1 RET_1800-2100_X-A/RET_unused_X-A Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Kathrein 80010892V01 3 1 86010153V01 XXXXX-Y2 80010892V01_Y2 RET_1800-2100_X-B/RET_unused_X-B Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Kathrein 80010892V01 4 1 86010153V01 XXXXX-Y3 80010892V01_Y3 RET_1800-2100_X-A/RET_unused_X-A Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Kathrein 80010892V01 5 1 86010153V01 XXXXX-Y4 80010892V01_Y4 RET_1800-2100_X-B/RET_unused_X-B Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Kathrein 80010872

Sample shown Y1 Y3 is used. Other sites could be used Y1 Y2 or Y2 Y3


RET mapping need to inline with actual port. Actual Connection check is needed.
For preventive, Y1, Y2, Y3 Tilt should be set as same value.

Antenna Type ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Kathrein 80010872 1 1 86010153 XXXXX-R1 80010872_R1 RET_900_X
Kathrein 80010872 2 1 86010153 XXXXX-Y1 80010872_Y1 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Kathrein 80010872 3 1 86010153 XXXXX-Y2 80010872_Y2 RET_1800-2100_X-B/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Kathrein 80010872 4 1 86010153 XXXXX-Y3 80010872_Y3 RET_1800-2100_X-B/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3 should set same
Huawei AQU4518R9

Sample shown RB LB is used. Other sites could be used


RB LT or LB LT.
RET mapping need to inline with actual port. Actual
Connection check is needed.
For preventive, RB LB LT Tilt should be set as same value.
Antenna Type ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Huawei AQU4518R9 1 1 RET INSIDE XXXXXLB AQU4518R9 RET_1800-2100_X-A Check Actual connection, Angle LB, RB, LT should set same
Huawei AQU4518R9 2 1 RET INSIDE XXXXXRB AQU4518R9 RET_1800-2100_X-B Check Actual connection, Angle LB, RB, LT should set same
Huawei AQU4518R9 3 1 RET INSIDE XXXXXXr AQU4518R9 RET_900_X
Huawei AQU4518R9 4 1 RET INSIDE XXXXXLT AQU4518R9 RET_unused_X Check Actual connection, Angle LB, RB, LT should set same
Huawei AQU4518R9v06

Sample shown Ly1 RTy2 is used. Other sites could be used Ly1 RBy3 or RTy2 RBy3.
RET mapping need to inline with actual port. Actual Connection check is needed.
For preventive, Ly1 RTy2 RBy3 Tilt should be set as same value.
Ladder Antenna Type Variant ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Ladder 2 Huawei AQU4518R9v06 1 1 1 AIMM20M22v01 XXXXXr1 AQU4518R9v06 RET_900_X
Ladder 2 Huawei AQU4518R9v06 1 2 1 AIMM20M22v01 XXXXXLy1 AQU4518R9v06 RET_1800-2100_X-A Check Actual connection, Angle Ly1, RTy2, RBy3 should set same
Ladder 2 Huawei AQU4518R9v06 1 3 1 AIMM20M22v01 XXXXXRTy2 AQU4518R9v06 RET_1800-2100_X-B Check Actual connection, Angle Ly1, RTy2, RBy3 should set same
Ladder 2 Huawei AQU4518R9v06 1 4 1 AIMM20M22v01 XXXXXRBy3 AQU4518R9v06 RET_unused_X Check Actual connection, Angle Ly1, RTy2, RBy3 should set same
Ladder 2 Huawei AQU4518R9v06 2 1 1 AIMM20M22 XXXXXr1 AQU4518R9v06 RET_900_X
Ladder 2 Huawei AQU4518R9v06 2 2 1 AIMM20M22 XXXXXLy1 AQU4518R9v06 RET_1800-2100_X-A Check Actual connection, Angle Ly1, RTy2, RBy3 should set same
Ladder 2 Huawei AQU4518R9v06 2 3 1 AIMM20M22 XXXXXRTy2 AQU4518R9v06 RET_1800-2100_X-B Check Actual connection, Angle Ly1, RTy2, RBy3 should set same
Ladder 2 Huawei AQU4518R9v06 2 4 1 AIMM20M22 XXXXXRBy3 AQU4518R9v06 RET_unused_X Check Actual connection, Angle Ly1, RTy2, RBy3 should set same
Kathrein 84510892

RET mapping need to inline with actual port. Actual Connection check is needed.
For preventive, Y1, Y2, Y3, Y4 Tilt should be set as same value.
Ladder Antenna Type ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Ladder 2 Kathrein 84510892 1 1 32892 YXNXXX_R1 84510892_R1 RET_900_X
Ladder 2 Kathrein 84510892 2 1 32892 YXNXXX_Y1 84510892_Y1 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Ladder 2 Kathrein 84510892 3 1 32892 YXNXXX_Y2 84510892_Y2 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Ladder 2 Kathrein 84510892 4 1 32892 YXNXXX_Y3 84510892_Y3 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Ladder 2 Kathrein 84510892 5 1 32892 YXNXXX_Y4 84510892_Y4 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Ladder 2 Kathrein 84510892 1 1 32100 YXMXXX_R1 84510892_R1 RET_900_X
Ladder 2 Kathrein 84510892 2 1 32100 YXMXXX_Y1 84510892_Y1 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Ladder 2 Kathrein 84510892 3 1 32100 YXMXXX_Y2 84510892_Y2 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Ladder 2 Kathrein 84510892 4 1 32100 YXMXXX_Y3 84510892_Y3 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
Ladder 2 Kathrein 84510892 5 1 32100 YXMXXX_Y4 84510892_Y4 RET_1800-2100_X-A/RET_unused_X Check Actual connection, Angle Y1,Y2,Y3, Y4 should set same
LADDER 3
Rosenberger MB-G64O9X65V-00

Y1 Y2 for Multi Sector


Y3 Y4 for Main Sector

Ladder Antenna Type Variant ALD RETU ALD productCode ALD serialNumber antModel sectorID
Ladder 3 Rosenberger MB-G64O9X65V-00 1 1 1 ECU-003L XXXXX-MM 675375-R1 RET_900_X
Ladder 3 Rosenberger MB-G64O9X65V-00 1 1 2 ECU-003L XXXXX-MM 675375-Y1/2 RET_1800-2100_MX-A/B
Ladder 3 Rosenberger MB-G64O9X65V-00 1 1 3 ECU-003L XXXXX-MM 675375-Y3/4 RET_1800-2100_X-A/B
Ladder 3 Rosenberger MB-G64O9X65V-00 2 1 1 ECU-003L XXXXX-MM 676777-R1 RET_900_X
Ladder 3 Rosenberger MB-G64O9X65V-00 2 1 2 ECU-003L XXXXX-MM 676777-Y1/2 RET_1800-2100_MX-A/B
Ladder 3 Rosenberger MB-G64O9X65V-00 2 1 3 ECU-003L XXXXX-MM 676777-Y3/4 RET_1800-2100_X-A/B
Ladder 3 Rosenberger MB-G64O9X65V-00 3 1 1 ECU-003L XXXXX-MM 678111-R1 RET_900_X
Ladder 3 Rosenberger MB-G64O9X65V-00 3 1 2 ECU-003L XXXXX-MM 678111-Y1/2 RET_1800-2100_MX-A/B
Ladder 3 Rosenberger MB-G64O9X65V-00 3 1 3 ECU-003L XXXXX-MM 678111-Y3/4 RET_1800-2100_X-A/B
Ladder 3 Rosenberger MB-G64O9X65V-00 4 1 1 ECU-003L XXXXX-MM K006246-R1 RET_900_X
Ladder 3 Rosenberger MB-G64O9X65V-00 4 1 2 ECU-003L XXXXX-MM K006246-Y1Y2 RET_1800-2100_MX-A/B
Ladder 3 Rosenberger MB-G64O9X65V-00 4 1 3 ECU-003L XXXXX-MM K006246-Y3Y4 RET_1800-2100_X-A/B
Rosenberger G4WHE-01V

Y1 Y2 for Multi Sector


Y3 Y4 for Main Sector

Antenna Type ALD RETU ALD productCode ALD serialNumber antModel sectorID
Rosenberger G4WHE-01V 1 1 SCU-002L XXXXX-MM K004637-R1 RET_900_X
Rosenberger G4WHE-01V 1 2 SCU-002L XXXXX-MM K004637-Y1 RET_1800-2100_MX-A
Rosenberger G4WHE-01V 1 3 SCU-002L XXXXX-MM K004637-Y2 RET_1800-2100_MX-B
Rosenberger G4WHE-01V 1 4 SCU-002L XXXXX-MM K004637-Y3 RET_1800-2100_X-A
Rosenberger G4WHE-01V 1 5 SCU-002L XXXXX-MM K004637-Y4 RET_1800-2100_X-B
Commscope R2HH-6533D-R5

B1 B3 for Multi Sector


B2 B4 for Main Sector

Ladder Antenna Type Variant ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Ladder 3 Commscope R2HH-6533D-R5 1 1 COMMRET2 CNXXXXXB1 R2HH-6533D-R5 RET_1800-2100_MX-A B1=Y1
Ladder 3 Commscope R2HH-6533D-R5 2 1 COMMRET2 CNXXXXXB3 R2HH-6533D-R5 RET_1800-2100_MX-B B3=Y2
Ladder 3 Commscope R2HH-6533D-R5 3 1 COMMRET2 CNXXXXXB2 R2HH-6533D-R5 RET_1800-2100_X-A B2=Y3
Ladder 3 Commscope R2HH-6533D-R5 4 1 COMMRET2 CNXXXXXB4 R2HH-6533D-R5 RET_1800-2100_X-B B4=Y4
Ladder 3 Commscope R2HH-6533D-R5 5 1 COMMRET2 CNXXXXXR1 R2HH-6533D-R5 RET_900_X R1=R1
Commscope R2HH-6533C-R3

Y1 Y3 for Multi Sector


Y2 Y4 for Main Sector

Ladder Antenna Type Variant ALD RETU ALD productCode ALD serialNumber antModel sectorID Remarks
Ladder 3 Commscope R2HH-6533C-R3 1 1 COMMRET2 CNXXXXXR1 R2HH-6533C-R3 RET_900_X
Ladder 3 Commscope R2HH-6533C-R3 2 1 COMMRET2 CNXXXXXY1 R2HH-6533C-R3 RET_1800-2100_MX-A/B CNXXXXXY1 RET covering Multi sector Cell (Y1-Y3)
Ladder 3 Commscope R2HH-6533C-R3 3 1 COMMRET2 CNXXXXXY2 R2HH-6533C-R3 RET_1800-2100_X-A/B CNXXXXXY2 RET covering Main sector Cell (Y2-Y4)
Project Briefing (Kickoff) 6 March_Customer
Final

Potrebbero piacerti anche