Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
MEMBRANE ULTRAFILTRAZIONE
ULTRAFILTRATION MEMBRANES
hytek Hydrotecnologies
Hydrotecnologies
hytek Hydrotecnologies
Questo capitolo rapresenta una descrizione dei moduli Du- This section includes the description of DuPont Ultrafiltration
Pont Ultrafiltration SFP / D-2660, SFP / D-2860, SFP / D-2880, In- SFP/D-2660, SFP/D-2860, SFP/D-2880, IntegraFlux™ SFP/D-
tegraFlux ™ SFP / D- 2860XP, SFP / D-2880XP, IntegraPac ™ IP 2860XP, SFP/D-2880XP modules, IntegraPac™ IP/D-51, In-
/ D-51, IntegraPac Moduli e skid ™ IP / D-77, IntegraPac ™ IP tegraPac™ IP/D-77, IntegraPac™ IP/D-51XP, IntegraPac™
/ D-51XP, IntegraPac ™ IP / D-77XP e moduli IntegraFlux ™ IP/D- 77XP modules and skids and IntegraFlux™ UXA-2680XP
UXA-2680XP. modules.
Caratteristiche del modulo di ultrafiltrazione DuPont DuPont Ultrafiltration Module Features
I moduli di ultrafiltrazione DuPont sono realizzati con membrane The DuPont Ultrafiltration Modules are made of high strength,
a fibra cava ad alta resistenza aventi le seguenti carattersistiche: hollow fiber membranes with features and benefits including:
• Pori con diametro nominale di 0,03 µm idonei alla rimozione • 0.03 µm nominal pore diameter for removal of bacteria, vi-
di batteri, virus e particolati inclusi i colloidi. ruses, and particulates including colloids.
• Compatte fibre in PVDF per un’elevata resistenza mecca- • PVDF fibers free of macro voids for high mechanical stren-
nica e un’eccellente resistenza chimica per garantire lunga gth with excellent chemical resistance offering long
durata e maggiore affidabilità. membrane life and reliable operation.
• Fibre in PVDF idrofilico per una facile pulizia e bagnabilità • Hydrophilic PVDF fibers for easy cleaning and wettability
per un mantenimento a lungo termine delle prestazioni. that help maintain long term performance.
• Flusso dall’ esterno verso l’ interno per un’elevato carico di • Outside-In flow configuration for high tolerance to feed so-
di solidi in alimento e una migliorata pulibilità con aria. lids and the use of air scour cleaning.
• Il guscio estero in PVC-U è caratterizzato da un’ ottima resisten- • U-PVC housings eliminate the need for pressure vessels and
za ai raggi UV ed elimina la necessità di vessels ad alta pressione. are resistant to UV light.
• Inoltre i moduli XP offrono una permeabilità superiore fino al • In addition, the XP fiber products provide up to 35% higher
35% rispetto ai moduli della generazione precedente, miglio- permeability than previous generation modules improving
randone così l’efficienza e la produttività. operating efficiencies and productivity.
La configurazione di flusso dall’ esterno verso l’ interno, con- The outside-in flow configuration allows the use of highly ef-
sente una migliore pulizia con aria e migliora sia la rimozione fective air scour cleaning which enhances particle removal
delle particelle che il recupero. La modalità operativa in “de- and improves recovery. A dead-end flow format achieves hi-
ad-end”consente maggiori recuperi e sensibili risparmi ener- gher recovery and energy savings. The module housing desi-
getici. Il design del modulo elimina la necessità di disporre gn eliminates the need for separate pressure vessels while the
separatamente i vessels e il loro orientamento verticale con- vertical orientation allows gravity draining and facilitates the
sente sia lo svuotamento per gravità che l’ eliminazione dell’ removal of air from cleaning and integrity testing processes.
Una sezione trasversale della fibra è mostrata in figura 7/ A cross section of the standard fiber is shown in Figure 7.
La figura 7 mostra la sezione standard di una fibra / Figure Wall Cross Section of the Hollow Fiber
1126
Una sezione trasversale della fibra è mostrata in figura 7/ A cross section of the standard fiber is shown in Figure 7.
Hydrotecnologies hytek
aria nei processi di pulizia. Le membrane a fibra cava hanno The hollow fiber membranes are 1.3 mm outside diameter
un diametro esterno di 1,3 mm e interno di 0,7 mm e sono and 0.7 mm inside diameter and are made from PVDF poly-
realizzate con polimero in PVDF. Le fibre sono resistenti gra- mer. The fibers are strong because of a combination of the
zie al polimero in PVDF, una sottostruttura densa con strato PVDF polymer, dense substructure and selective active layer
attivo e selettivo disposto verso il lato di alimento della fibra. formed on the feed side of the fiber. The PVDF membranes
Le membrane in PVDF offrono un’elevata resistenza chimica, offer high chemical resistance, coping with NaOCl concen-
permettendo concentrazioni di NaOCl fino a 2000 mg/L e trations up to 2000 mg/L, and are tolerant to temperatures
temperature di 40 ° C. L’idrofilia delle fibre in PVDF è ottenuta of 40°C. The hydrophilicity of the PVDF fibers is increased by
in prduzione grazie ad un trattamento a marchio brevettato. using a proprietary treatment during manufacturing.
La dimensione nominale dei pori da 0,03 μm combina eleva- The 0.03 μm nominal pore size combines high filtration perfor-
La figura 7 mostra la sezione standard di una fibra / Figure Wall Cross Section of the Hollow Fiber
te prestazioni con alte portate. I pori più piccoli rispetto alle mance and high flux. The smaller pore size provides stabile
membrane di microfiltrazione offrono prestazioni più stabili a long term filtration performance compared to microfiltration
lungo termine. membranes.
Certificazioni Doupont ultrafiltrazione DuPont Ultrafiltration Certifications
La tabella 4 illustra le certificazioni per il portafoglio dei pro- Table 4 covers the certifications for the DuPont Ultrafiltration
dotti di Ultrafiltrazione della DuPont. product portfolio.
Per rimuovere il liquido conservante presente nei moduli DuPont, The DuPont Ultrafiltration Modules should be rinsed prior to
questi devono essere risciacquati prima dell’avvio. Il lavaggio startup to remove preservative fluid shipped in the modules.
deve essere prolungato fino a quando non si vede più schiu- Flushing should be performed until no foam is observed in the
ma nell’acqua di lavaggio. A seconda del tipo di applicazione, wash water. Depending on the treatment application, addi-
può essere necessario un ulteriore risciacquo e smaltimento del tional rinsing or disposal of the filtrate may be required.
filtrato. I moduli certificati NSF 61 / ANSI richiedono le seguenti NSF / ANSI Standard 61 certified modules require the following
procedure di risciacquo prima di produtte acqua potabile: conditioning rinse prior to producing potable water:
1. Sciacquare i moduli ad una velocità di filrazione di almeno 1. Rinse the modules at a feed rate of 40 LMH minimum for a
40 LMH per un periodo di 4 ore. period of 4 hours.
2. Raggiungere un volume di risciacquo totale minimo di 160 2. Achieve a minimum total rinse volume of 160 LMH hours
LMH ore utilizzando l’acqua disponibile in alimento. using the feed water available.
3. La velocità di spurgo del concentrato deve essere impo- 3. The concentrate bleed rate should be set from between
stata tra 0 e 20% di quanto filtrato. 0 – 20% with the balance being filtrate.
4. Durante il ciclo di risciacquo, eseguire i protocolli standard 4. During the rinse cycle, perform standard cleaning protocols
di DuPont specificamente studiati per i tipi di acqua in ali- as per DuPont’s recommendations which are specifically de-
mento. signed to consider the feed water quality available.
5. Il filtrato non deve essere utilizzato come acqua potabile 5. The filtrate should be sent to the appropriate disposal sy-
e deve essere raccolto in un sistema di smaltimento appro- stem based on the regulations that apply to the location
priato in base alle norme applicabili nel luogo in cui viene where the conditioning rinse is carried out and not used as
effettuato il risciacquo. potable water.
6. Le normative locali potrebbero richiedere un ulteriore con- 6. Local regulations may require additional conditioning of
dizionamento del sistema prima di produrre acqua potabile. the system prior to producing potable water.
1127
hytek Hydrotecnologies
Module:
IntegraPac™
Module:
IntegraPac™ Skid:
IntegraPac™
IntegraFlux™SFD/SFP series:
Skid:
IntegraPac™
Famiglia DouPont moduli di Utrafiltrazione SFP/D e IntegraFlux™ / Family of DuPont Ultrafiltration SFP/D
and IntegraFlux™ modules
1128
Hydrotecnologies hytek
DESCRIZIONE DEL PROCESSO DI ULTRAFILTRAZIONE DUPONT DUPONT ULTRAFILTRATION PROCESS DESCRIPTION
Le condizioni operative base dei moduli di ultrafiltrazione Du- The basic operating conditions for the DuPont Ultrafiltration
Pont sono riportate di seguito nella Tabella 9. I parametri ope- Modules are shown in Table 9 below. Operating parameters
rativi per le fasi di pulizia sono forniti nella Sezione 6. for the cleaning steps are provided in Section 6.
All’avvio dell’impianto, i moduli devono essere lavati per ri- At initial plant start-up the modules must be flushed in order to
muovere eventuali residui di sostanze chimiche e/o aria rima- remove any residual storage chemicals or air trapped during
sta intrappolata durante l’installazione. Il flusso di risciacquo è the module installation. This flush occurs on the outside of the
all’esterno delle fibre, cioè non viene prodotto alcun filtrato. fibers, i.e., no filtrate is produced. Once the initial flush is done,
Una volta terminato il lavaggio, l’impianto può iniziare a pro- the plant can begin producing filtrate. When starting the ini-
durre. All’avvio, il flusso deve essere aumentato gradualmen- tial filtration cycle the flow should be slowly increased before
te fino al raggiungimento delle condizioni di progetto. being put into operation at the design conditions.
FILTRAZIONE FILTRATION
Il più delle volte i sistemi di ultrafltrazione operano filtrando Ultrafiltration systems are most of the time in Filtration mode
tutto il flusso in alimento. L’acqua in ingresso viene pompata while in operation. The feed water is pumped through the
attraverso la membrana e convertita in filtrato. In genere tutti membrane and is converted to filtrate.
i flussi in ingresso vengono convertiti in filtrato, in quella che Typically all feed is converted to filtrate, in what is referred as
viene definita filtrazione senza scarto “dead-end” (diversa- dead-end filtration
mente dalla filtrazione definita in “cross-flow” in cui una parte (as opposed to cross-flow filtration where a fraction of the
dell’ alimento viene scartato). In genere i cicli di filtrazione feed leaves the system as reject).
hanno una durata che va dai 20 ai 90 minuti, a seconda delle Filtration cycles typically range from 20 – 90 minutes, depen-
caratteristiche dell’ alimento. La Figura 25 mostra uno sche- ding on the feed water source and quality. Figure 25 shows a
ma del ciclo di ultrafiltrazione DuPont. diagram of the Filtration step in DuPont Ultrafiltration Modules.
Fig.25
I sistemi di ultrafiltrazione sono in genere progettati per funzio- Ultrafiltration systems are typically designed to operate at
nare a portata costante. Man mano che i solidi si accumulano constant flowrate. As the solids build on the membrane surfa-
sulla superficie della membrana, la pressione transmembrana ce, the transmembrane pressure (TMP) increases and even-
(TMP) aumenta e alla fine i contaminanti devono essere rimossi tually the foulants must be removed through a Backwash se-
attraverso un controlavaggio. Il controlavaggio generalmente quence. The Backwash sequence is generally initiated based
inizia dopo un certo tempo di funzionamento. In alternativa, on time.
può essere avviato anche in base al volume del filtrato o con Alternatively, it can be initiated based on volume of filtrate
un differenziale di pressione (quest’ultimo è consigliato quando or TMP set point (the latter is more appropriate for highly va-
l’ alimento è variabile). Il cliclo di controlavaggio include insuf- riable feed water quality). The Backwash sequence includes
flamento di aria, scarico a gravità, controlavaggio con flusso di- Air Scour, Gravity Drain, Backwash through the module top
retto all’uscita superiore del modulo, controlavaggio con flusso outlet, Backwash through the module bottom outlet and a
diretto verso l’uscita inferiore del modulo e un flussaggio finale. final Forward Flush or rinse.
1129
hytek Hydrotecnologies
Fig.26
1130
Hydrotecnologies hytek
CONTROLAVAGGIO DALL’ ALTO BACKWASH TOP
Dopo la fase di scarico per gravità, viene avviata la fase di After the gravity drain step, the backwash step is initiated. Fil-
controlavaggio. L’acqua filtrata viene pompata al contrario, trate water is pumped backwards, i.e., from the inside to the
cioè dall’interno verso l’esterno delle fibre, al fine di spingere il outside of the fibers, in order to push the accumulated mate-
materiale accumulato dalla membrana. Quindi viene espul- rial off the membrane. Then it is flushed out to waste through
so per essere scaricato attraverso l’uscita superiore del mo- the top module outlet (see Figure 28). The Backwash flux ran-
dulo (vedi Figura 28). Il flusso di controlavaggio varia da 100 a ges from 100 – 120 LMH, and the duration of the step is 30 – 45
120 LMH e dura 30 - 45 secondi. A volte, a seconda dell’appli- seconds. Sometimes, depending on the application, chlorine
cazione, può essere aggiunto al flusso di controlavaggio del might be added to the backwash stream to help remove
cloro per aiutare a rimuovere i contaminanti o inibire l’attività foulants or inhibit microbiological activity. Air scour can be
microbiologica. Può anche essere abbinata aria per aumen- combined with the Backwash Top step to increase cleaning
tare l’ efficacia di pulizia. effectiveness.
Fig.28
1131
hytek Hydrotecnologies
Fig.30
1132
Hydrotecnologies hytek
MODULI DuPont SERIE 26 e 28 / DuPont UF and 26/28 SERIES MODULES
Il modulo 2660 è una è un’ eccellente scelta per sistemi con The 2660 module is an excellent choice for systems capaci-
produzione fino a 50 m3 / ora (220 gpm). Questo modulo da ties of 50 m3/hr (220 gpm) or less. This 1.5 m (60 inch) length
1,5 m (60 pollici) offre efficienze più elevate rispetto a mo- module offers higher efficiencies over a wider range of feed
duli di lunghezza superiore. Il modulo con diametro di 15 cm water conditions compared to longer length modules. The 15
(6 pollici) consente un design più compatto per installazioni cm (6 inch) diameter module allows a more compact design
compatte. Il 2860, il più corto, è consigliato per tutti i sitemi for space constrained installations.
dove occorre limitare l’ altezza. Il 2880 ha una superficie fil- The 2860, which is shorter in length, is recommended for smal-
trante superiore al 2860 pur mantenendo la stessa impronta ler systems and where building height is a concern. The 2880
del modello 2860, permettendo la realizzazione di sistemi più has higher membrane area for the same footprint offering a
economici. Su ogni modulo ci sono quattro connessioni. Il flus- more economical design.
so in ingresso entra e viene distribuito nei moduli attraverso There are four connections in each module. Feed flow en-
la porta di alimentazione laterale situata nella parte laterale ters and is distributed into the modules through the side feed
inferiore di ciascun modulo. L’ingresso dell’aria si trova nel- port located at the side bottom of each module. The air inlet
la parte inferiore e viene utilizzato per il lavaggio con aria e is located at the bottom of the module and is used for air
per i test d’ integrità. Il concentrato (scarico proveniente dall’ scouring and integrity testing. The concentrate (discharge of
esterno della fibra) è la porta posta in alto al centro, mentre il waste flows from the outside of the fiber) is the top central
filtrato (flusso all’interno della fibra) si trova nella porta lateria- port and the filtrate (inside of fiber) is located at the side top
le e superiore del modulo. port of the module.
La Tabella 5 mostra le dimensioni, i collegamenti e le specifi- Table 5 shows dimensions, connections and specifications for
che riferite ai moduli di Ultrafiltrazione DuPont SFP/D e SFP/D the DuPont Ultrafiltration SFP/D and SFP/D XP modules family,
XP, come illustrato nelle pagine seguenti. Sottolineiamo che as depicted in the next pages. Note that manufacturing and
le tolleranze di fabbricazione, di espansione termica e lo thermal expansion tolerances and the thickness of the base
spessore della clip di base, non sono inclusi nella tabella. Per clip are not included in the dimensions below. Refer to the
queste informazioni riferirsi ai disegni d’ installazione. installation drawings for this information.
Tabella 5 / Table 5
Pr oduct Name DuPont Ul t r af i l t r at i on S F P/D and Int egr aF l ux™S F P/D XP modul es f ami l y
SFP/D-2860 SFP/D-2880
Product Model SFP/D-2660
SFP/D-2860XP SFP/D-2880XP
Units SI US SI US SI US
ActiveArea 33 m2 355 ft 2 51m2 549 ft 2 77m2 829 ft 2
1500
Fibers Length 59.1in 1500 mm 59.1in 2000 mm 78.7in
mm
MaxModuleInlet Pressure
6.25 bar 90.65 psi 6.25 bar 90.65 psi 6.25 bar 90.65 psi
@ 20°C/68°F
MaxModuleInlet Pressure
4.75 bar 68.89 psi 4.75 bar 68.89 psi 4.75 bar 68.89 psi
@ 40°C/104°F
Length - L 1863mm 73.3in 1863mm 73.3in 2363mm 93.0 in
1500
Length - L1 59.1in 1500 mm 59.1in 2000 mm 78.7in
mm
Length - L2 1613mm 63.5 in 1633mm 64.3 in 2133mm 84.0 in
Length - L3 1713mm 67.4 in 1823mm 71.8in 2323mm 91.4in
Diameter 165mm 6.5 in 225 mm 8.9 in 225 mm 8.9 in
Width - W1 125mm 4.9 in 180 mm 7.1in 180 mm 7.1in
Width - W2 250 mm 9.8 in 342 mm 13.5in 342 mm 13.5in
Empty / Shipping/ Flooded 25/30/41 55/66/90
48/55/83 106/121/183 61/71/100 135/156/220
Weight kg lbs
Volumeper module 16L 4.2 gal 35 L 9.3 gal 39 L 10.3gal
DN50 NPS 2"
DN50 NPS 2" DN50 NPS 2"
FeedPort Side Side
Side Coupling Side Coupling Side Coupling Side Coupling
Coupling Coupling
DN50 NPS 2"
DN50 NPS 2" DN50 NPS 2"
Filtrate Port Side Side
Side Coupling Side Coupling Side Coupling Side Coupling
Coupling Coupling
NPS 1
DN32
1/4" DN50 NPS 2" DN50 NPS 2"
Concentrate Port Top
Top Top Coupling Top Coupling Top Coupling Top Coupling
Coupling
Coupling
G3/8” (Standard)or DN32Glued G3/8” (Standard)or DN32Glued
Air Scour Connection G3/8” (Standard)
Fitting (Option)Bottom Fitting (Option)Bottom
Housing UPVC UPVC UPVC UPVC UPVC UPVC
1133
hytek Hydrotecnologies
Description The DuPont ultrafiltration (UF) modules are made from high
strength, hollow fiber membranes that have excellent features
and benefits:
0.03 µm nominal pore diameter for removal of bacteria,
viruses, and particulates including colloids to protect
downstream processes, such as RO
PVDF polymeric hollow fibers for high strength and chemical
resistance allows longer membrane life
Hydrophilic PVDF fibers for easy cleaning and wettability that
help maintain long term performance
Outside In flow configuration for high tolerance to feed solids
that helps reduce the need for pretreatment processes
U-PVC housing, helping to eliminate the need for costly pressure vessels
This module is an ideal choice for systems capacities of 50 m3/hr (220 gpm) or less. The
shorter, 60 inch length module offers higher efficiencies over a wider range of feed water
conditions compared to longer length modules. The smaller, 6 inch diameter module
allows a more compact design for space constrained installations.
DuPont Ultrafiltration Modules can be used for a wide variety of treatment applications
such as surface water, seawater, industrial wastewaters, and secondary effluent
wastewater.
Typical Properties
Weight
Membrane area Module volume (empty/ water filled)
Model Type Part # m2 ft2 liters gallons kg lbs
1134
Hydrotecnologies hytek
Dimensions SFP and SFD 2660 (6-inch diameter)
Important Proper start-up of an ultrafiltration system is essential to prepare the membranes for
Information operating service and to prevent membrane damage. Following the proper start-up
sequence also helps ensure that system operating parameters conform to design
specifications so that system water quality and productivity goals can be achieved.
Before initiating system start-up procedures, membrane pretreatment, installation of the
membrane modules, instrument calibration and other system checks should be
completed.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
Operation Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other
Guidelines sequences to prevent possible membrane damage. Flush the ultrafiltration system to
remove shipping solution prior to start-up. Remove residual air from the system prior to
start-up. Manually start the equipment. Depending on the application, filtrate obtained
from initial operations should be discarded.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
General If operating limits and guidelines given in this bulletin are not strictly followed, the
Information limited warranty will be null and void.
To control biological growth during extended system shutdowns, it is recommended
that storage solution be injected into the membrane modules.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en) and
Technical Service Bulletins.
1135
Product DuPont has a fundamental concern for all who make, distribute, and use its products, and
for the environment in which we live. This concern is the basis for our product stewardship
hytek Hydrotecnologies
Esploso DuPont Modello SFP-2660 e SFD-2660 / DuPont Spare Parts Modules Model SFP-2660
and SFD-2660
1136
Hydrotecnologies hytek
Moduli Ultrafiltrazione DuPont Modello SFP-2860, SFD 2860, SFP-2880 e SFD-2880 / DuPont Ultrafil-
tration Modules Model SFP-2860, SFD 2860, SFP-2880 and SFD-2880
Description DuPont Ultrafiltration (UF) modules are made from high mechanical
strength, PVDF hollow fiber membranes. The modules provide excellent
performance andindustry leading membrane area. These modules have the
following properties and characteristics:
0.03 µm nominal pore diameter for removal of bacteria, viruses, and
particulates including colloids to protect downstream processes
such as RO
PVDF polymeric hollow fibers for high mechanical strength and
chemical resistance providing long membrane life and reliable
operation.
Hydrophilic PVDF fibers for easy cleaning and wettability that help
maintain long term performance
Outside-In flow configuration allowing a wide range of solids in the
feed water minimizing the need for pretreatment processes and
reducing the backwash volume compared to Inside-Out
configurations U-PVC housing, helping to eliminate the need for
costly pressure vessels
Typical Properties
Weight
Membrane Area Hold-Up Volume (empty/water filled)
Product Type m2 ft2 liters gallons kg lbs
SFP-2860 Industrial 51 549 35 9.3 48/83 106/183
SFD-2860 NSF/ANSI 61 51 549 35 9.3 48/83 106/183
Drinking Water
SFP-2880 Industrial 77 829 39 10.3 61/100 135/220
SFD-2880 NSF/ANSI 61 and 419 77 829 39 10.3 61/100 135/220
Drinking Water
1137
hytek Hydrotecnologies
Important Proper start-up of an ultrafiltration system is essential to prepare the membranes for
Information operating service and to prevent membrane damage. Following the proper start-up
sequence also helps ensure that system operating parameters conform to design
specifications so that system water quality and productivity goals can be achieved.
Before initiating system start-up procedures, membrane pretreatment, installation of the
membrane modules, instrument calibration and other system checks should be
completed.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
Operation Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other
Guidelines sequences to prevent possible membrane damage. Flush the ultrafiltration system to
remove shipping solution prior to start-up. Remove residual air from the system prior to
start-up. Manually start the equipment. Depending on the application, filtrate obtained
from initial operations should be discarded.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
General l If operating limits and guidelines given in this bulletin are not strictly followed, the
Information limited warranty will be null and void.
l To control biological growth during extended system shutdowns, it is recommended
that storage solution be injected into the membrane modules.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en) and
Technical Service Bulletins.
Product DuPont has a fundamental concern for all who make, distribute, and use its products, and
Stewardship for the environment in which we live. This concern is the basis for our product stewardship
philosophy by which we assess the safety, health, and environmental information on our
1138 products and then take appropriate steps to protect employee and public health and our
environment. The success of our product stewardship program rests with each and every
individual involved with DuPont products—from the initial concept and research, to
Hydrotecnologies hytek
Esploso DuPont Modello SFP-2860, SFD 2860, SFP-2880 e SFD-2880 / DuPont Spare Parts Model
SFP-2860, SFD 2860, SFP-2880 and SFD-2880
1139
hytek Hydrotecnologies
Moduli Ultrafiltrazione DuPont Modello SFP-2860XP, SFD 2860XP, SFP-2880XP e SFD-2880XP / Du-
Pont Ultrafiltration Modules Model SFP-2860XP, SFD 2860XP, SFP-2880XP and SFD-2880XP
Typical Properties
Weight
Membrane Area Volume (empty/water filled)
Product Type m2 ft 2 liters gallons kg/lbs kg/lbs
SFP-2860XP Industrial 51 549 35 9.3 48/83 106/183
SFD-2860XP NSF/ANSI 61 and 419 51 549 35 9.3 48/83 106/183
SFP-2880XP Industrial 77 829 39 10.3 61/100 135/220
SFD-2880XP NSF/ANSI 61 and 419 77 829 39 10.3 61/100 135/220
1140
Hydrotecnologies hytek
Dimensions SFP-2860XP, SFD-2860XP, SFP-2880XP, and SFD-2880XP (8-inch diameter)
Operation Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other
Suggested SI Units
sequences to prevent possible membrane damage.2 Flush the ultrafiltration system to
US Units
Guidelines
Operating Filtrate Flux (25ºC) 40 – 110 l/m hr 24 – 65 gfd
remove shipping solution prior to start-up. Remove3 residual air from the system prior to
Flow Range Per Module1 2.0 8.5 m /hr 8.8 37.4 gpm
Conditions start-up. Manually start the equipment. Depending on the application, filtrate obtained
Temperature 1 40ºC 34 104ºF
from initial operations should be discarded. – –
Maximum Inlet ModulePressure (20ºC) 6.25 bar 90.65 psi
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
– –
Maximum Inlet ModulePressure (40ºC) 4.75 bar 68.89 psi
General If operating limits and guidelines given in2.1
Maximum Operating TMP
this
bar
bulletin are not strictly30.5
followed, the
psi
Information limited warranty will be
Maximum Operating Air Scour Flow
null and void. 3
12 Nm /hr 7.1 scfm
To control biological growth during extended
Maximum BackwashPressure
system shutdowns, it is
2.5 bar
recommended
36 psi
that storage
Operating pH
solution be injected into the membrane modules.
2 11
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en) and
Maximum NaOCl 2,000 mg/L
Technical Service Bulletins. –
Maximum Particle Size 300 µm
Flow Configuration Outside in, dead end flow
Expected Filtrate Turbidity ≤ 0.1 NTU
Expected Filtrate SDI ≤ 2.5
1
Flow range represents DUPONT™ Ultrafiltration SFP-2860XP, SFD-2860XP, SFP-2880XP, and SFP-2880XP
Product DuPont has a fundamental concern for all who make, distribute, and use its products, and
Modules for filtrate flux range shown
Stewardship for the environment in which we live. This concern is the basis for our product stewardship
Important Proper
philosophy upwhich
start-by of an ultrafiltration
we assess the system
safety,ishealth,
essential
andto prepare the membranes
environmental informationfor on our
Information operating service and to prevent membrane damage. Following
products and then take appropriate steps to protect employee and public healththe proper start-up
and our
sequence also helps
environment. The
ensure that system operating parameters
success of our product stewardship
conform to design
program rests with each and every
specifications so that system water quality and productivity goals can be achieved.
individual involved with DuPont products—from the initial concept and research, to
Before initiating system start-up procedures,
manufacture, use, sale, disposal,
membrane pretreatment, installation of the
and recycle of each product.
membrane modules, instrument calibration and other system checks should be
completed.
DuPont strongly encourages its customers to review both their manufacturing processes
Customer Notice Please
and theirrefer to the Ultrafiltration
applications of DuPontTechnical
products from the(Form
Manual No. 45-D00874-en).
standpoint of human health and
Operation Avoid
environmental quality to ensure that DuPont products are not usedcleaning
any abrupt pressure variations during start-up, shutdown, in ways or forother
which they
Guidelines sequences to prevent possible membrane damage. Flush the ultrafiltration
are not intended or tested. DuPont personnel are available to answer your questions system and
to to
remove reasonable
provide shipping solution prior
technical to start-up.
support. DuPont Remove
productresidual air from
literature, the system
including prior to
safety data
start-up. Manually start the equipment. Depending on the application, filtrate
sheets, should be consulted prior to use of DuPont products. Current safety data sheets are obtained
from initialfrom
available operations
DuPont.should be discarded.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
General If operating
Please
be aware limits
of theand guidelines given in this bulletin are not strictly followed, the
following:
Information limited
warranty will be
The use of this product null in
and void.
and of itself does not necessarily guarantee the removal
To control biological growth during
of cysts and pathogens from water. extended cyst shutdowns,
system
Effective and pathogen is recommended
it reduction is
that dependent
storage solution be injected into the membrane modules.
on the complete system design and on the operation and maintenance
Please of refer
theto the Ultrafiltration Technical Manual (Form No. 45-D00874-en) and
system.
Technical Service Bulletins.
Regulatory Note NSF/ANSI 61 and 419 certified drinking water modules require specific conditioning
procedures prior to producing potable water. Please refer to the Ultrafiltration Technical
Manual (Form No. 45-D00874-en) flushing section for specific procedures. Drinking
water modules may be subjected to additional regulatory restrictions in some countries.
Product Please
DuPont check local regulatory
has a fundamental guidelines
concern for all and
whoapplication statusand
make, distribute, before
useuse and sales.
its products, and 1141
Stewardship for the environment in which we live. This concern is the basis for our product stewardship
philosophy by which we assess the safety, health, and environmental information on our
products and then take appropriate steps to protect employee and public health and our
hytek Hydrotecnologies
Esploso DuPont Modello SFP-2860XP, SFD 2860XP, SFP-2880XP e SFD-2880XP / DuPont Spare
Parts Model SFP-2860XP, SFD 2860XP, SFP-2880XP and SFD-2880XP
1142
Hydrotecnologies hytek
Moduli serie IntegraFlux™ / IntegraFlux™ Series Modules
I moduli di ultrafiltrazione IntegraFlux ™ con fibra XP sono realiz- IntegraFlux™ Ultrafiltration Modules with XP fiber are made
zati con membrane in PVDF a fibra cava ad alta permeabilità from high permeability, high mechanical strength, hollow
ed elevata resistenza meccanica. I moduli offrono prestazioni fiber PVDF membranes. The modules provide excellent per-
eccellenti, una superficie filtrante che la rende leader nel setto- formance, industry leading membrane area with low energy
re grazie ai bassi consumi energetici e di prodotto chimico. I mo- and chemical consumption. IntegraFlux™ modules have up
duli IntegraFlux ™ hanno una permeabilità fino al 35% superiore to 35% higher permeability than previous generation modules,
rispetto ai moduli della generazione precedente, contribuendo helping to improve operating efficiencies and productivity.
al miglioramento dell’efficienza operativa e della produttività. These modules are an excellent choice for systems with ca-
Questi moduli sono ideali per la realizzazione di impianti con pacities greater than 50 m3/hr (220 gpm). The shorter SFP-
produzione superiore a 50 m3 /ora (220 gpm). I moduli più corti, 2860XP or SFD-2860XP modules are well suited for installations
SFP-2860XP e SFD-2860XP, sono adatti per installazioni con altez- with limited height. Larger and longer, 20 cm (8 inch) diame-
za limitata. I moduli più grandi SFP-2880XP e SFD-2880XP, hanno ter and 2 m (80 inch) in length, the SFP-2880XP or SFD-2880XP
un diametro di 20 cm (8 pollici) e un’ altezza di 2 m (80 pollici), e modules offer a high effective membrane area combined
offrono una grande area filtrante con un’alta permeabilità per with high permeability that provides the most economical
sistemi più efficienti ed economici. Sono presenti quattro con- and efficient membrane system design.
nessioni per ciascun modulo. Il flusso da filtrare entra e viene di- There are four connections in each module. Feed flow en-
stribuito nei moduli attraverso la porta di alimentazione laterale ters and is distributed into the modules through the side feed
situata nella parte inferiore di ciascun modulo. L’ingresso dell’a- port located at the side bottom of each module. The air inlet
ria si trova nella parte inferiore del modulo e viene utilizzato per is located at the bottom of the module and is used for air
il lavaggio con aria e i test d’ integrità. Il concentrato (scarico scouring and integrity testing. The concentrate (discharge of
proveniente dall’ esterno della fibra) si trova al centro nella par- waste flows from the outside of the fiber) is the top central
te superiore, mentre il filtrato (flusso interno della fibra) è posto port and the filtrate (inside of fiber) is located at the side top
sempre nella parte superiore ma laterale. port of the module.
Moduli di Ultrafiltrazione IntegraPac™ IntegraPac™ Ultrafiltration Modules
Il design innovativo del tappo terminale aiuta l’accoppia- Innovative end-cap design helps direct coupling of Integra-
mento diretto dei moduli IntegraPac ™ riducendo la neces- Pac™ modules reducing the need for piping and manifolds.
sità di tubazioni e collettori. Questi moduli sono la scelta ide- These modules are an ideal choice for systems requiring a
ale per i sistemi che richiedono un ingombro ridotto. I moduli small footprint. The IP-77 and IPD-77 modules offer a high ef-
IP-77 e IPD-77 offrono un’area filtrante che contribuisce a fective membrane area, which contributes to a more econo-
un design compatto ed economico. I moduli IP-51 e IPD-51 mical membrane system design. The IP-51 and IPD-51 modules
sono più corti in altezza e sono adatti per applicazioni in cui are shorter in height and are suitable for applications where
esiste un vincolo di spazio. Il modulo IP-77XP offre un’area there is a head space constraint. The IP-77XP module offers a
filtrante con fibre ad alta permeabilità capaci di rendere high effective membrane area combined with high permea-
ancora più efficiente ed economico il sistema. Il modulo IP- bility fibers that offer an economical and efficient membra-
51XP è più corto in altezza ed è adatto per applicazioni in ne system design. The IP-51XP module is shorter in height and
cui questa rappresenta un limite, massimizzando la produt- is suitable for applications where height is a constraint while
tività e l’efficienza tramite fibre ad alta permeabilità. Il mo- maximizing productivity and efficiency with high permeability
dulo IntegraPac ™ viene mostrato in Figura 13. Vi sono sei fibers. The IntegraPac™ module is shown in Figure 13. There
connessioni su ciascun modulo. Il flusso in alimento entra nei are six connections on each module. Feed flow enters and is
moduli e viene distribuito attraverso le porte laterali situate distributed into the modules through the side feed ports loca-
sul tappo terminale inferiore (flusso out side-in). Il collega- ted on the bottom end cap. Feed flow enters the module on
mento dell’aria si trova sul lato terminale del tappo inferiore the outside of the fiber. The air connection is located on the
e viene utilizzato per il lavaggio con aria e per i test d’ inte- side of the bottom end cap and is used for air scouring and
grità. Il concentrato (scarico proveniente dall’ esterno della integrity testing. The concentrate (discharge of waste flows
fibra) si trova al centro nella parte superiore, mentre il filtrato from the outside of fiber) and filtrate port (inside of fiber) are
(flusso interno della fibra) è posto sempre nella parte supe- located on the top cap. Included with the module are the
riore ma lateralmente. couplers, air fitting, and transparent filtrate elbow.
La tabella 6 mostra le dimensioni, i collegamenti e le specifiche Table 6 shows dimensions, connections and specifications for
dei moduli IntegraPac ™ IP-51, IntegraPac ™ IP-77 e Integra- the IntegraPac™ IP-51, IntegraPac™ IP-77 and IntegraPac™
Pac ™ IP-51XP, IntegraPac ™ IP-77XP. Notare che le tolleranze IP-51XP, IntegraPac™ IP-77XP modules family. Note that ma-
di fabbricazione, di espansione termica e lo spessore della clip nufacturing and thermal expansion tolerances and the thi-
di base non sono inclusi nelle dimensioni seguenti. Per queste ckness of the base clip are not included in the dimensions
informazioni fare riferimento ai disegni d’ installazione. below. Refer to the installation drawings for this information.
Tab.6
Pr oduct Name Int egr aPac™f ami l y
IP/D-51 IP/D-77
Pr oduct Model
IP/D-51XP IP/D-77XP
Units SI US SI US
2 2 2
ActiveArea 51m 549 ft 77 m 829 ft 2
Fibers Length 1500 mm 59.1in 2000 mm 78.7in
MaxInlet Pressure @ 20°C/68°F 6.25 bar 90.65 psi 6.25 bar 90.65 psi
MaxInlet Pressure @ 40°C/104°F 4.75 bar 68.89 psi 4.75 bar 68.89 psi
Length - L 1998mm 78.28 in 2488 mm 97.95 in
Length - L1 1500 mm 59.1in 2000 mm 78.7in
Length - L2 1689mm 66.5 in 2189mm 86.2 in
Length - L3 1864mm 73.4in 2364 mm 91.3in
Diameter 225 mm 8.9 in 225 mm 8.9 in
Width - W1 360 mm 14.2in 360 mm 14.2in
Width - W2 342 mm 13.5in 342 mm 13.5in
Empty/ Shipping/ FloodedWeight 53/60/102 117/132/225 66/72/119 146/158/262
Volumeper module 49 L 13gal 53 L 14gal
DN100 NPS 4" DN100 NPS 4"
FeedPort
Side Coupling Side Coupling Side Coupling Side Coupling
DN40 NPS 11/2" DN40 NPS 11/2"
Filtrate Port
Top Union Top Union Top Union Top Union
DN100 NPS 4" DN100 NPS 4"
Concentrate Port
Side Coupling Side Coupling Side Coupling Side Coupling
Air ScourConnection G 3/8” G 3/8”
Housing UPVC UPVC UPVC UPVC
1144
Hydrotecnologies hytek
Moduli Ultrafiltrazione modello IP-51, IPD-51, IP-77, e IPD-77 / IntegraPac™ Ultrafiltration Modu-
les Model IP-51, IPD-51, IP-77, and IPD-77
Typical Properties
Weight
Membrane Area (empty/water filled) Hold-Up Volume
Product Type m2 ft 2 kg lbs liters gallons
IP-51 Industrial 51 549 53/102 117/225 49 13
IPD-51 NSF/ANSI 61 51 549 53/102 117/225 49 13
Drinking Water
IP-77 Industrial 77 829 66/119 146/262 53 14
IPD-77 NSF/ANSI 61 and 419 77 829 66/119 146/262 53 14
Drinking Water
1145
hytek Hydrotecnologies
Dimensions
Important Proper start-up of an ultrafiltration system is essential to prepare the membranes for
Information operating service and to prevent membrane damage. Following the proper start-up
sequence also helps ensure that system operating parameters conform to design
specifications so that system water quality and productivity goals can be achieved.
Before initiating system start-up procedures, membrane pretreatment, installation of the
membrane modules, instrument calibration and other system checks should be
completed.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
Operation Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other
Guidelines sequences to prevent possible membrane damage. Flush the ultrafiltration system to
remove shipping solution prior to start-up. Remove residual air from the system prior to
start-up. Manually start the equipment. Depending on the application, filtrate obtained
from initial operations should be discarded.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
General If operating limits and guidelines given in this bulletin are not strictly followed, the
Information limited warranty will be null and void.
To control biological growth during extended system shutdowns, it is recommended
that storage solution be injected into the membrane modules.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en) and
Technical Service Bulletins.
Product DuPont has a fundamental concern for all who make, distribute, and use its products, and
Stewardship for the environment in which we live. This concern is the basis for our product stewardship
philosophy by which we assess the safety, health, and environmental information on our
products and then take appropriate steps to protect employee and public health and our
1146 environment. The success of our product stewardship program rests with each and every
individual involved with DuPont products—from the initial concept and research, to
manufacture, use, sale, disposal, and recycle of each product.
Hydrotecnologies hytek
Moduli Ultrafiltrazione modello IP-51XP, IPD-51XP, IP-77XP, e IPD-77XP / IntegraPac™ Ultrafiltra-
tion Modules Model IP-51XP, IPD-51XP, IP-77XP, and IPD-77XP
Typical Properties
Weight
Membrane Area (empty/water filled) Hold-Up Volume
Product Type m2 ft 2 kg lbs liters gallons
IP-51XP Industrial 51 549 53/102 117/225 49 13
IPD-51XP NSF/ANSI 61 and 419 51 549 53/102 117/225 49 13
IP-77XP Industrial 77 829 66/119 146/262 53 14
IPD-77XP NSF/ANSI 61 and 419 77 829 66/119 146/262 53 14
1147
hytek Hydrotecnologies
Dimensions
Important Proper start-up of an ultrafiltration system is essential to prepare the membranes for
Information operating service and to prevent membrane damage. Following the proper start-up
sequence also helps ensure that system operating parameters conform to design
specifications so that system water quality and productivity goals can be achieved.
Before initiating system start-up procedures, membrane pretreatment, installation of the
membrane modules, instrument calibration and other system checks should be
completed.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
Operation Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other
Guidelines sequences to prevent possible membrane damage. Flush the ultrafiltration system to
remove shipping solution prior to start-up. Remove residual air from the system prior to
start-up. Manually start the equipment. Depending on the application, filtrate obtained
from initial operations should be discarded.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en).
General If operating limits and guidelines given in this bulletin are not strictly followed, the
Information limited warranty will be null and void.
To control biological growth during extended system shutdowns, it is recommended
that storage solution be injected into the membrane modules.
Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en) and
Technical Service Bulletins.
Product DuPont has a fundamental concern for all who make, distribute, and use its products, and
Stewardship for the environment in which we live. This concern is the basis for our product stewardship
philosophy by which we assess the safety, health, and environmental information on our
1148 products and then take appropriate steps to protect employee and public health and our
environment. The success of our product stewardship program rests with each and every
individual involved with DuPont products—from the initial concept and research, to
manufacture, use, sale, disposal, and recycle of each product.
Hydrotecnologies hytek
Esploso modello IP-51XP, IPD-51XP, IP-77XP, e IPD-77XP / Spare Parts Model IP-51XP, IPD-51XP,
IP-77XP, and IPD-77XP
1149
hytek Hydrotecnologies
Lo skid IntegraPac ™ con moduli IP / D-51 (XP) o IP / D-77 (XP) è The IntegraPac™ skid with IP/D-51(XP) or IP/D-77(XP) modules
basato su un design standard pre-ingegnerizzato costituito da is a pre-engineered, standardized skid design consisting of In-
moduli di Ultrafiltrazione IntegraPac ™, accessori e tubazioni. È tegraPac™ Ultrafiltration Modules, auxiliary parts and piping.
progettato per semplificare significativamente la fase di proget- It is designed to significantly streamline design, assembly and
tazione, assemblaggio e installazione, comprimendo al massi- installation, making possible lower skid costs, reduced engine-
mo i costi, facilitare il montaggio e riducendo gli ingombri e i ering design costs, easy assembly, smaller footprint and shor-
tempi di consegna. Le caratteristiche peculiari sono: tened delivery schedule. Features include:
• L’accoppiamento diretto dei moduli elimina le tubazioni extra, • Direct coupling of modules eliminate ancillary piping, help
aiutando a ridurre gli ingombri e i costi. saving costs and reducing footprint.
• Kit modulare e scalabile per progettazioni che coprono una • Modular and scalable for design across a wide range of
vasta gamma di portate. flowrates.
• Materiali di alta qualità e resistenti alla corrosione grazie ad un’ • Materials of construction selected for corrosion resistance
ampia compatibilità chimica. and chemical compatibility.
• Spedito in kit non assemblati per una riduzione dei costi di tra- • Shipped unassembled to lower transportation cost and help
sporto e minori rischi di rotture dovue allo stesso. prevent damage in transit.
• I componenti standardizzati e prefabbricati, eliminano la misu- • Standardized and pre-fabricated components eliminate
razione, il taglio, l’incollaggio e la saldatura. measuring, cutting, gluing and welding.
• Facilmente accessibile per le ispezioni, manutenzioni o sosti- • Easily accessible for physical inspection or replacement at
tuzioni. end of life.
• Raccordo per il filtrato a gomito di facile utilizzo e di colore • Operator-friendly transparent filtrate elbow designed and
trasparente, progettato per una facile verifica d’ integrità. located for easy visual integrity inspection.
• Idoneo per alta pressione per consentire l’alimentazione diret- • High pressure rating to enable direct feed to reverse osmosis
ta con la pompa ad alta pressione dell’ impianto osmosi. feed pumps.
La Tabella 7 illustra i dettagli degli skid per IntegraPac ™ IP / D-51, Table 7 shows skid details for the IntegraPac™ IP/D-51, Inte-
IntegraPac ™ IP / D-77 e IntegraPac ™ IP / D-51XP, IntegraPac graPac™ IP/D-77 and IntegraPac™ IP/D-51XP, IntegraPac™
™ kid IP / D-77XP, illustrati nella Figura 15 e nella Figura 16. IP/D-77XP skids, as depicted in Figure 15 and Figure 16.
1150
Hydrotecnologies hytek
Tab.7
1151
hytek Hydrotecnologies
Tab.15
1152
Hydrotecnologies hytek
Tab.16
1153
hytek Hydrotecnologies
dizzer® XL: Moduli di Ultrafiltrazione per soluzioni personalizza- dizzer® XL: Ultrafiltration modules for custom rack solutions in
te su skid an open platform configuration.
dizzer® L Series dizzer® L Series
Moduli di ultrafiltrazione a cartuccia per una semplice sosti- Cartridge type ultrafiltration modules for streamlined replace-
tuzione del singolo modulo in un impianto. ment of individual membrane filtration elements.
dizzer® P dizzer® P
Moduli di Ultrafiltrazione a cartuccia per applicazioni su pic- Cartridge type ultrafiltration modules for small-scale applica-
cola scala, ad es. al punto d’ uso e al punto d’ ingresso. tions, e.g. point-of-use and point-of-entry.
T-Rack 3.0® T-Rack 3.0®
Skid ottimizzato per l’uso su impianti di grandi dimensioni, ad Optimized rack for use in large-scale plants e.g. pretreat-
es. sistemi di pretrattamento per la dissalazione dell’acqua ment systems for sea water desalination and waste water
di mare e il riutilizzo delle acque reflue. reuse.
LA FAMIGLIA DI PRODOTTI INGE® THE INGE® PRODUCT FAMILY
• Tecnologia a membrana Multibore® • Multibore® Membrane Technology
La membrana Multibore® sviluppata da inge GmbH (vedi The Multibore® membrane developed by inge GmbH
Figura 2.1-1) combina sette capillari dello stesso diametro in (see Figure 2.1-1) combines seven capillaries of the
un’unica fibra. Ciò fornisce una stabilità meccanica significa- same diameter into a single fiber. This provides signi-
tivamente più elevata rispetto alle convenzionali membrane ficantly higher mechanical stability than conventional
a fibra cava a singolo foro. Le membrane Multibore® vengo- singlebore hollow fiber membranes. Multibore® membra-
no generalmente utilizzate in modalità senza uscita e vengo- nes are typically operated in dead-end mode and are
no lavate ad intervalli regolari. In linea di principio è anche backwashed at regular intervals. Crossflow operation at low
possibile il funzionamento a flusso tangenziale a basse veloci- velocities is also feasible in principle, though it is only used in
tà, sebbene venga utilizzato solo in determinate circostanze. certain circumstances.
1154
Hydrotecnologies hytek
portate di controlavaggio e una minor area della membra- backwash water and a smaller membrane area.
na (impianto più picolo). Le fibre con un diametro capillare Fibers with a capillary diameter larger than > 0.9 mm (> 0.035
maggiore di > 0,9 mm (> 0,035 pollici) sono la scelta per quel- inch) are the choice for applications involving continuously
le applicazioni con elevati livelli di solidi, come ad esempio le high levels of solids – for example backwash waters of con-
acque di controlavaggio di filtri convenzionali o i sistemi UF di ventional media filters, or 2nd-stage UF systems (treating the
2 ° stadio (trattamento dell’acqua di lavaggio non chimica di non-chemical backwash water of a 1st-stage UF system). As a
un sistema UF di 1 ° stadio). Come indicazione, questi capillari first indication these larger capillaries should be considered
più grandi, dovrebbero essere impiegati per acque con con- for water with a concentration of suspended solids grea-
centrazioni di solidi sospesi superiori ai 50 mg / l. La decisione ter than 50 mg/l. The final decision for the used capillary
finale e la scelta del diametro, dipende da diversi fattori come: diameter is depending on different factors like filtration
il tempo di filtrazione, il tempo di controlavaggio e la natura time, backwash time and the nature of the particles. The lar-
delle particelle. Un diametro più grande aumenta significa- ger diameter significantly increases the solids content that
tivamente la quantità di solidi che possono essere gestiti dai can be handled by the capillaries and in principle, enables
capillari e, in linea di principio, consente velocità di flusso più higher flow velocities and lower pressure drops in a semi cros-
elevate e minori perdite di carico nei sistemi semi-tangenziali. sflow operation, if employed.
La membrana Multibore® viene “filata” in una singola fase di The Multibore® membrane is “spun” in a single production
produzione e ricavata da una sola soluzione polimerica in un step from just one polymer solution in a patented production
processo brevettato. La rotazione delle membrane tramite l’ process. Spinning the membranes using just one material cre-
utilizzo di un solo materiale, crea una membrana “integrale”. ates what is known as an “integral” membrane. Unlike com-
A differenza delle membrane composite, che sono costituite posite membranes, which consist of multiple layers of va-
da più strati di vari materiali, le membrane integrali non pre- rious materials, integral membranes do not pose the risk of
sentano il rischio di distaccamento dei singoli strati. Questo individual layers peeling away. This is a huge advantage
è un enorme vantaggio in termini d’ integrità del prodotto. in terms of membrane integrity.
Il materiale della membrana a base di PES, viene modificato The PES based membrane material is modified in a way that
in modo da aumentare l’idrofilia della stessa. Questa mag- boosts the hydrophilicity of the membrane. This increased hy-
giore idrofilia riduce la tendenza che ha la superficie della drophilicity reduces the tendency of the membrane surface
membrana ad assorbire sostanze organiche, migliorandone to adsorb organics, thereby improving operating performan-
così le prestazioni a livello di incrostazioni. Il processo di pro- ce with less membrane fouling. The manufacturing process
duzione da origine ad una superficie filtrante sottile definita produces a defined thin filtration surface (interface) on the
(interfaccia) con all’interno sette capillari con bassissima resi- inside of the seven capillaries with extremely low resistance to
stenza alla permeabilità e con pori interni che misurano circa permeation and with inner pores measuring approximately
20 nanometri (vedere Figura 2.1-2). Questa dimensione dei 20 nanometers (see Figure 2.1-2). This pore size is sub-
pori è sostanzialmente inferiore rispetto alle altre membra- stantially smaller compared to low pressure membranes
ne ad ultrafiltrazione a bassa pressione presenti sul mercato. of most other ultrafiltration membranes on the market. This
Ciò garantisce una reiezione del virus di oltre 4 log senza la ensures a virus rejection of more than 4 log units without any
necessità di pretrattamento (come ad es. la coagulazione), pretreatment step like coagulation and in addition a better
apportando anche una migliore rimozione dei contaminanti removal of foulants if used as pretreatment for reverse osmo-
utilizzati per gli impianti ad osmosi inversa. Nonostante i pori sis plants. In spite of the smaller pores, the Multibore® mem-
più piccoli, la membrana Multibore® mostra una permeabilità brane shows a substantially higher permeability because
sostanzialmente più elevata grazie alla sua maggiore porosi- of the higher surface porosity. This is translated into a very
tà. Questo si traduce in un’ alto un risparmio energetico. energy efficient operation.
I singoli capillari sono saldamente collegati tra loro da una The individual capillaries are firmly connected to each other
struttura di supporto omogenea che ha una permeabilità di by a homogeneous support structure that has a permeability
circa 1.000 volte superiore a quella dell’ effettiva interfaccia some 1,000 times higher than that of the actual filtration
di filtrazione dei capillari. Questi sono posizionati a distan- interface of the capillaries. The capillaries are spaced at
ze definite tra loro per garantire una distribuzione uniforme defined distances from each other to ensure a uniform distri-
dell’acqua all’interno della membrana Multibore® garanten- bution of water within the Multibore® membrane and superior
do altresì una stabilità complessiva superiore. overall stability.
Pori più piccoli, pressione più bassa, resistenza ineguagliabile Smaller pores, lower pressure, the unmatched resistance
a pulizie chimiche con alti valori di pH per la rimozone di so- against high pH cleaning for removing organic foulants
stanze organiche e, naturalmente, la sua stabilità, sono solo al- and of course the stability are only a few unique characteri-
cune delle caratteristiche che rendono Multibore® PES unica. stics of the Multibore® PES membrane.
Le membrane di ultrafiltrazione Multibore® funzionano “al Multibore® ultrafiltration membranes operate “inside-out”,
contrario”, il che significa che l’acqua di alimentazione viene which means that the feed water flows from the inside
1155
hytek Hydrotecnologies
filtrata dall’interno verso l’esterno dei capillari, mentre il con- to the outside of the capillaries in filtration mode and flows in
trolavaggio scorre nella direzione opposta, cioè dall’esterno the reverse direction, i.e. from the outside to the inside of the
all’interno dei capillari. capillaries, in backwash mode.
Le membrane di ultrafiltrazione inge® Multibore® rimuovo- inge® Multibore® ultrafiltration membranes reliably remove
no dall’acqua in modo affidabile, particelle, batteri e virus, particles, bacteria and viruses from a variety of water
anche in condzioni di variabilità dell’ affluente. Il manteni- sources, even if fluctuations in the quality of the feed wa-
mento dell’integrità delle fibre preseni nella membrana è un ter exist. Maintaining the integrity of the membrane fibers is
prerequisito fondamentale per garantire che i contaminanti a key prerequisite for ensuring that contaminants are properly
vengano rimossi correttamente dal sistema. Sebbene i difetti removed from the system. Although capillary defects are ex-
capillari siano estremamente improbabili a causa della stra- tremely unlikely due to the extraordinary stability of Multibore®
ordinaria stabilità delle Multibore®, l’integrità delle membrane membranes, the integrity of the membranes or capillaries can
o dei capillari può essere negativamente influenzata da so- still be affected negatively by factors such as non-approved
stanze non tollerate nell’acqua di alimentazione e, in partico- substances in the feed water and, in particular, by excessive
lare, da eccessivi ed improri stress meccanici. mechanical stress caused by improper operation.
• Tecnologia dei moduli dizzer® • dizzer® Module Technology
Le membrane UF sviluppate da inge, GmbH vengono inserite The UF membranes developed by inge GmbH are enca-
all’ interno di un vessel in pressione. Questi fanno parte della sed in a pressure housing. The resulting array is known as
serie inge® dizzer® ovvero dei moduli verticali, che racchiu- the vertical inge® dizzer® module Series, which includes uni-
dono caratteristiche e design unici per applicazoni in ultrafil- que design features tailored to the specific requirements
trazione nel settore del trattamento delle acque. Particolare of ultrafiltration in the water treatment industry. Particular
attenzione è stata prestata all’ottimizzazione delle caratteri- attention has been paid to optimizing the hydrodynamic
stiche idrodinamiche del modulo interno al fine di migliorare characteristics of the internal module design in order to
l’efficienza del controlavaggio e l’integrità della membrana. improve backwash efficiency and membrane integrity.
MODALITÀ OPERATIVE DELLA MEMEBRANA MEMEBRANE OPERATING MODES
• Filtrazione • Filtration
Nella modalità di filtrazione, l’acqua da filtrare viene trattata In filtration mode, the source water is treated by being
spingendola dentro la membrana di ultrafiltrazione dal lato forced through the ultrafiltration membrane from the feed
di alimentazione verso il lato del filtrato. I contaminanti dell’ side to the filtrate side. The contaminants in the water,
acqua, che vengono bloccati dall’ area filtrante, si concen- which are blocked by the filtration surface, accumulate
trano sulla superficie interna dei capillari. Il filtrato fluisce nel on the inner surface of the membrane capillaries. The filtrate
serbatoio del trattato / controlavaggio, che funge sia da flows into the filtrate/backwash tank, which serves as a sto-
contenitore per l’acqua di controlavaggio che d’ accumulo rage container for the backwash water and the water
per l’acqua destinata ad ulteriori processi o consumi. In alter- that is to be used for further processing or consumption.
nativa, il filtrato potrà essere convogliato direttamente alle Alternatively, the filtrate can be piped directly to the ultima-
utenze finali. In questo caso il serbatoio avrà esclusivamente te consumers, in which case the tank is used solely as a
la funzione di stoccaggio per l’ acqua di lavaggio. La quan- storage container for backwash water. The amount of
tità di acqua che può essere trattata da ciascun modulo UF, water that can be treated by each UF module depends on
dipende da una serie di fattori, incluso l’origine dell’acqua a number of factors, including the origin of the water being
da trattare (ad es. acqua di falda, acque superficiali, acqua treated (e.g. ground water, surface water, sea water, or pre-
di mare o acque reflue pretrattate), le sue caratteristiche (ad treated waste water), the composition of the source water
es. torbidità, quantità di solidi, sostanze organiche / inorga- (e.g. turbidity, concentration of solids, dissolved organics/
niche, temperatura) e la strategia di costo prescelta (costo inorganics, temperature), and the chosen cost strategy
capitale, costi operativi). (capital cost, operating costs).
I seguenti schemi illustrano le due modalità operative: “Fil- The diagrams below show the two operating modes “Filtration
trazione dall’ alto” e “Filtrazione dal basso” in modalità “de- Top” and “Filtration Bottom” in dead-end mode. Figure 3.1-1
ad-end” (senza scarico). La Figura 3.1-1 mostra una “filtrazio- shows filtration being performed from top (FT) with the sour-
ne dall’alto” (FT) eseguita alimentando il modulo nella parte ce-water being fed into the top of the module, while Figure
superiore, mentre la Figura 3.1-2 mostra una “filtrazione dal 3.1-2 shows filtration being performed from bottom (FB) with
basso” con alimento del modulo dal basso. the source-water being fed into the bottom of the module.
Feed Top
Feed BW Drain
Top Top Filtrate FILTRATE
Filtrate
BW
Supply
Control Valve
FEED Feed BW Drain UF
Bottom Bottom Module(s)
Feed Bottom
BACKWASH
WASTE
Caustic
Hypo
Acid
CEB
Feed Top
Feed BW Drain
Top Top Filtrate FILTRATE
Filtrate
BW
Supply
Control Valve
FEED Feed BW Drain UF
Bottom Bottom Module(s)
Feed Bottom
BACKWASH
WASTE
Caustic
Hypo
Acid
CEB
1157
hytek Hydrotecnologies
Serie dizzer ® XL W per installazioni in piattaforma / dizzer ® XL W Series for Open Platform
Installation
Module Specifications
Module reference dizzerXL ® dizzerXL ® dizzerXL ® dizzerXL ® dizzerXL ®
0.9 MB 38 W 0.9 MB 60 W 0.9 MB 80 W 1.5 MB 25 W 1.5 MB 40 W
Module type 1 2 3 1 2
Module type 1 2 3
Module length (L) mm inch 985 ±1.5 38.78 1485 ±1.5 58.46 1720 ±1.5 67.72
Distance top / bottom feed port (L1) mm inch 1100 ±3 43.31 1600 ±3 62.99 1834 ±3 72.20
Length with end caps (L2) mm inch 1180 ±3 46.46 1680 ±3 66.14 1914 ±3 75.35
Common Characteristics
Dimensions
B
Distance feed top port - filtrate port (B) mm inch 190 ±1.5 7.48 D d
Outer diam. end cap coupling max. (C) mm inch 295 11.61
L2
L
Material
1158
Hydrotecnologies hytek
dizzer ® XL W Series| for Open Platform Installation
dizzer ® XL W Series| for Open Platform Installation
Pressure
Pressure
Maximumoperating
Maximum operatingpressure
pressure[4]
[4]
bar
bar psi psi5 5 72 72
Maximumrate
Maximum rateofofpressure
pressurechange
change bar/sec
bar/sec psi/sec
psi/sec 0.5 0.5 7.25 7.25
Note
[1] Module with Connecting Kit (end caps and couplings).
The descriptions, designs, data and product information contained herein are
Please contact inge GmbH if you want to order replacement Note in good faith and are based on inge GmbH’s current knowledge
presented
[1] Module with Connecting Kit (end caps and couplings).
modules without Connecting Kit. and The descriptions,
experience. designs,
inge GmbH data accept
cannot and product information
any liability contained
for the accuracy of herein
this are
Please contact inge GmbH if you want to order replacement
Modules are delivered with end caps ports aligned with the presented
product in good
information, whichfaith and are
is provided at nobased
charge onand ingeforGmbH’s
guidancecurrent
only. ingeknowledge
modules without Connecting Kit. and experience.
products are designedinge to beGmbH cannot
operated accept anywith
in accordance liability
the for the accuracy of this
corresponding
filtrate / backwash port with a tolerance of ± 3 mm.
Modules arethat
delivered with end caps ® product
In the event the alignment needs toports aligned the
be modified, withend
the inge product information, which isThe
documentation. provided
product at information
no charge and andfor guidance
products areonly. inge
filtrate / backwash port with a tolerance products
protected by are designed
copyright to be
and/or operated
other in accordance
intellectual property laws with the corresponding
worldwide.
cap couplings can be loosened to align theof ± 3caps
end mm. ports with
In the event that the alignment needs to be modified, end However, inge ®inge GmbHdocumentation.
product cannot guarantee Thethat the product
product information
information and
and products are
the filtrate / backwash port as desired. After alignment, thethe
end
products can beby
protected used without infringing
copyright third party
and/or other intellectual
intellectual property
property rights.
laws worldwide.
cap couplings can be loosened to align the
cap couplings must be fastened with a torque wrench whose end caps ports with
The However,
products and ingeproduct
GmbH information may onlythat
cannot guarantee be used, distributed
the product and
information and
the filtrate value
tightening / backwash
must beport as40
set at desired.
Nm. After alignment, the end marketed withcan
the beexpress
products usedprior permission
without infringingof inge
third GmbH. No warranties
party intellectual of
property rights.
[2] cap couplings
Please must
refer to the be fastened
latest version ofwith
the Multibore ®
a torque wrench whose
datasheet. any kind regarding the products, either expressed or implied, including, but not
The products and product information may only be used, distributed and
[3] tightening
For membrane value mustoperating
related be set atconditions,
40 Nm. please refer to [2]. limited to, warranties
marketed of merchantability,
with the fitness for a
express prior permission ofparticular
inge GmbH. purpose or no
No warranties of
[4] The design pressure ®datasheet. third party rights are made, other than as expressly set out in the contractual
[2] Please refer to the corresponds
latest versiontoofthe
themaximum
Multibore permitted any kind regarding the products, either expressed or implied, including, but not
agreement with the customer. Mechanical stability and full functionality
[3] operating
For membrane pressure in continuous
related operating operation at the
conditions, specified
please limited
refer to [2]. of inge to, warranties of merchantability, fitness for a®particular purpose or no
®products can only be provided by genuine inge parts. inge GmbH
[4] design temperature. Higher operating pressures
The design pressure corresponds to the maximum permitted than 5 bar may third party rights are made, other than as expressly set out in the contractual
reserves the right to modify products and product information at any time
be possible pressure
in certainincases. However, this mustatfirst bespecified
verified agreement with the customer. Mechanical stability and full functionality
operating continuous operation the without prior information. Current product information can be obtained from
®products can only be provided by genuine inge ® parts. inge GmbH
of ingewww.dupontwatersolutions.com
and approved by inge GmbH. the website
design temperature. Higher operating pressures than 5 bar may reserves the right to modify products and product information at any time
be possible in certain cases. However, this must first be verified without prior information. Current product information can be obtained from
and approved by inge GmbH. the website www.dupontwatersolutions.com
1159
hytek Hydrotecnologies
Module Specifications
Module reference dizzer ® XL dizzer ® XL dizzer ® XL dizzer ® XL dizzer ® dizzer ®
0.9 MB 36 WR 0.9 MB 60 WR 1.5 MB 25 WR 1.5 MB 40 WR 3000Plus WR 5000Plus WR
Module type 1 2 1 2 1 2
Module type 1 2
Module length (L) mm inch 985 ±1.5 38.78 1485 ±1.5 58.46
Distance top / bottom feed port (L1) mm inch 1100 ±3 43.31 1600 ±3 62.99
Length with end caps (L2) mm inch 1180 ±3 46.46 1680 ±3 66.14
Common Characteristics
Dimensions
B
Outer diam. end cap coupling max. (C) mm inch 295 11.61
L2
L
Material
1160
Hydrotecnologies hytek
dizzer ® XL/Plus WR Series | for Open Platform Installation
Note
[1] Module with Connecting Kit (end caps and couplings).
The descriptions, designs, data and product information contained herein are
Please contact inge GmbH if you want to order replacement
presented in good faith and are based on inge GmbH’s current knowledge
modules without Connecting Kit. and experience. inge GmbH cannot accept any liability for the accuracy of this
Modules are delivered with end caps ports aligned with the product information, which is provided at no charge and for guidance only. inge
filtrate / backwash port with a tolerance of ± 3 mm. products are designed to be operated in accordance with the corresponding
In the event that the alignment needs to be modified, the end inge ® product documentation. The product information and products are
Note
[1] Module with Connecting Kit (end caps and couplings). protected by copyright and/or other intellectual property laws worldwide.
cap couplings can be loosened to align the end caps ports with The descriptions, designs, data and product information contained herein are
Please contact inge GmbH if you want to order replacement However,
the filtrate / backwash port as desired. After alignment, the end
inge GmbH cannot guarantee that the product information and
presented in good faith and are based on inge GmbH’s current knowledge
products can be used without infringing third party intellectual property rights.
modules
cap without
couplings must Connecting Kit. a torque wrench whose
be fastened with and experience. inge GmbH cannot accept any liability for the accuracy of this
The products and product information may only be used, distributed and
Modules are
tightening delivered
value must bewith end
set at caps ports aligned with the
40 Nm. product
marketed withinformation,
the express which is provided
prior permission ofat no charge
inge GmbH. No andwarranties
for guidance
of only. inge
[2] filtraterefer
Please / backwash portversion
to the latest with aoftolerance of ± ®
the Multibore 3 datasheet.
mm. products
any kind are the
regarding designed to either
products, be operated
expressedinoraccordance with the
implied, including, corresponding
but not
[3] In the
For event that
membrane the alignment
related needs to be
operating conditions, modified,
please refer tothe
inge ® product documentation. The product information and products are
[2].end limited to, warranties of merchantability, fitness for a particular purpose or no
protected by copyright and/or other intellectual property laws worldwide.
[4] cap
The couplings
design cancorresponds
pressure be loosened to to
thealign the end
maximum caps ports withthird party rights are made, other than as expressly set out in the contractual
permitted
However,
agreement withinge
the GmbH
customer.cannot guarantee
Mechanical thatand
stability the full
product information and
functionality
the filtratepressure
operating / backwash port as operation
in continuous desired. After alignment,
at the specified the end ® products ® parts. inge
products
of inge can can
be used
only without infringing
be provided third party
by genuine inge intellectual property
GmbH rights.
design temperature.
cap couplings must Higher operating
be fastened withpressures
a torquethan 5 bar
wrench may
whose reserves
The the right toand
products modify products
product and product
information mayinformation
only be used, at anydistributed
time and
be possible invalue
tightening certain cases.
must However,
be set this must first be verified
at 40 Nm. without prior information.
marketed Current product
with the express information
prior permission can be
of inge obtained
GmbH. from
No warranties of
[2] and approved
Please refer toby inge
the latest version of the Multibore ® datasheet. the website
GmbH. any kindwww.dupontwatersolutions.com
regarding the products, either expressed or implied, including, but not
[3] For membrane related operating conditions, please refer to [2]. limited to, warranties of merchantability, fitness for a particular purpose or no
third party rights are made, other than as expressly set out in the contractual
[4] The design pressure corresponds to the maximum permitted
agreement with the customer. Mechanical stability and full functionality
operating pressure in continuous operation at the specified
of inge ® products can only be provided by genuine inge® parts. inge GmbH
design temperature. Higher operating pressures than 5 bar may reserves the right to modify products and product information at any time
be possible in certain cases. However, this must first be verified without prior information. Current product information can be obtained from
and approved by inge GmbH. the website www.dupontwatersolutions.com
1161
hytek Hydrotecnologies
LineGuard UF-100 è la nuova generazione di impianti di ultra- LineGuard UF-100 is the next generation of Point Of Entry ul-
filtrazione POE (Point Of Entry), in grado di erogare fino a 60 trafiltration systems, able to provide up to 60 LPM, removing
L/min., rimuovendo il 99,99% dei virus e dei batteri. LineGuard 99.99% of viruses and 99.99% of bacteria.
UF-100 dispone di due moduli di ultrafiltrazione X-Flow, con The LineGuard UF-100 has two X-Flow UF modules with billions
miliardi di pori microscopici, sufficientemente piccoli da trat- of microscopic pores small enough to retain all micro-organi-
tenere tutti i microorganismi, inclusi batteri e virus, cisti, sedi- sms including bacteria, viruses and cysts as well as sediment
menti e torbidità.. and turbidity
CARATTERISTICHE TECNICHE TECHNICAL CHARACTERISTICS
• Temperatura ambiente: min. +1 °C, max. +50 °C • Ambient temperature: min +1°C, max +50 °C
• Temperatura di stoccaggio: min. +1 °C, max. +50 °C • Storage temperature: min +1°C, max +50 °C
• Temperatura dell’acqua di alimentazione: min. +1 °C, max. +40 °C • Feed water temperature: min +1°C, max +40 °C
• Umidità relativa: fino al 100% • Relative humidity: up to 100%
• Tensione di alimentazione: 90-264 VCA • Supply voltage: 90-264 VAC
• Consumo energetico durante la pulizia: max. 20 W • Power consumption during cleaning: max. 20 W
• Consumo energetico durante la filtrazione: max. 1 W • Power consumption during filtering: max. 1 W
• Pressione in ingresso massima: 4 bar • Maximum inlet pressure: 4 bar
SPECIFICHE DEL PRODOTTO PRODUCT SPECIFICATIONS
• Acqua di alimentazione: 22 mm, 3/4” (raccordo a saldare • Feed water: 22 mm, 3/4 inch (solder or compression fit-
o a pressare) ting)
• Permeato: 22 mm, 3/4” (raccordo a saldare o a pressare) • Permeate: 22 mm, 3/4 inch (solder or compression fitting)
• Connessione allo scarico: 22 mm, 3/4” (raccordo a saldare • Connection to drain: 22 mm, 3/4 inch (solder or compression
o a pressare) fitting)
DIMENIONI E PESO DIMENSIONS AND WEIGHT:
• Prodotto: Altezza 1.150 mm/Larghezza 316 mm/Profondità • Product: Height 1150 mm/Width 316 mm/Depth 209 mm/
209 mm/Peso 38 kg Weight 38 kg
• Imballo: Lunghezza 1.200 mm/Larghezza 400 mm/Altezza • Packaging: Length 1200 mm/Width 400 mm/Height 350
350 mm/Peso 40 kg mm/Weight 40 kg
PRESTAZIONI PERFORMANCE
Portata iniziale(1): __________________________ 60 l/min. @ 2 bar, Initial flow rate(1): ________________________60 l/min @ 2 bar,
sufficiente per collegare 4 rubinetti sufficient for 4 tap connections
Capacità totale(1): ______________________________ > 5.000 m3 Total capacity(1): _______________________________________________________ > 5.000 m3
Efficienza impianto(1): ________________________________________________________ > 98% System efficiency(1): ___________________________________________________________ > 98%
Cicli di pulizia: ___ Controlavaggio e lavaggio in equicorrente Cleaning cycles: _______________ Backwash and forward flush
Superficie della membrana: ________________________ 4,5 m2 Membrane area: ___________________________________ 4.5 m2
Unità di controllo: ___________________________ Tipo CWS EC 2 Control unit: ________________________________ Type CWS EC 2
Menu lingua: __________ Inglese, tedesco, spagnolo, francese Menu language: __________ English, German, Spanish, French
Dati in ingresso: ________________ Parametri del ciclo di pulizia Input data: _____________________ Cleaning cycle parameters
Dati in uscita: _________________ Volume totale, perdita di ca- Output data: _________________ Total volume, pressure drop,
rico, indicazione delle prestazioni performance indication
CONFORMITÀ COMPLIANCE
Ritenzione biologica: ______________ Virus(2): > 99,99% (log 4) / Biological retention Viruses(2): ________________ >99.99% (log 4)
Batteri(3) > 99,99999% (log 7) Bacteria(3) : ______________________________>99.99999% (log 7)
Sicurezza dei materiali: ____ Prove di estrazione secondo NSF/KTW Material safety Extraction: _______ tests according to NSF/KTW
Integrità strutturale testata a: ____ Pressione idrostatica di 12 bar Structural integrity tested at: _____ Hydrostatic pressure 12 bar
NSF P231: _______________________________________ Conforme NSF P231: _______________________________________ Compliant
UL: _____________________________________________ Conforme UL: _____________________________________________ Compliant
KIWA ATA: _______________________ In attesa di approvazione KIWA ATA: ________________________________________ Pending
(1) Flow rates and capacity depend on incoming water conditions (1) Flow rates and capacity depend on incoming water conditions
(2) Tested by Vitens water research using MS2 bacteriophages (2) Tested by Vitens water research using MS2 bacteriophages
(3) Tested by KIWA water research using Legionella Pneumophilia (3) Tested by KIWA water research using Legionella Pneumophilia
1162
Hydrotecnologies hytek
DIMENSIONI / DIMENSIONS
10 10
210
100
1156
315
36
55
55
600
1 - Module left
4 4
2 - Module right
3 - NO feed water valve
Po 6
4 - NC drain valve
1 2 5 - Pressure sensor feed water Installazione tubazioni / Piping Installation
6 - Pressure sensor filtered water
3 3 7 - Flow sensor filtered water
Pi
8 - Feed water shut-off valve 1 - Drain
5
F with integrated drain valve
2 - Filtered water
7 9 - Bypass valve
3 - Feed water
10 - Filtered water shut-off valve
with integrated drain valve ø 22 mm pipe ends
11 - Feed water (adapter to 3/4”)
12 - Filtered water
13 - Drain
14 - Back flow preventor 1 2 3
15 - Pressure reducing valve
16 - Pressure relief valve
Remark: appendages 8-16 are not included with
the LineGuard
10 8
12 16
11
9 15 14
13
1163