Sei sulla pagina 1di 6

ASCENSORE PER AUTO MODELLO "CMC COVER B1 FREE Light "

Conoot so|uzioc c- -tziot|izzt-c stzi,


cvi1too |t cos1-uzioc oi t1ics1c1icc
-tnc o'tcccsso t| ct-tcc.
( La greenpark srl si riserva il dir it t o di apport ar e modifiche alle specifiche t ecniche)
Covcic1 so|u1io 1o -t1iot|izc stccs,
tvoioic 1c cos1-uc1io o tcs1c1ic ct-tcc
tcccssic -tns.
GREEN PARK SRL - VI A DEI COLLI n30 - 25013 CARPENEDOLO ( BS) - TEL.030/ 9698822 FAX 030/ 969303
www. greenparksrl.it mail: inf o@gr eenpar ksrl.it
CAR LI FT "CMC COVER B1Fr ee Light CAPACI TY KG 2500 mod."
( gr eenpar k r eser ves t he r ight t o modify t he t echnical specificat ions )
1
6
0
-
2
2
0
PORTA SEZI ONALE
AUTOMATI CA
I NGOMBRO A SOFFI TTO
MI N. 160mm MAX 220mm
4
0
0
PORTA AVVOLGI BI LE
AUTOMATI CA
400X450mm
PARAPETTO A PROTEZI ONE
DELLA FOSSA h 1200mm
CANCELLO AUTOMATI CO
COMPLETO DI SERRATURA
ELETTROMECCANI CA
OMOLOGATA
PESO E PORTATATA I N Kg MI SURE ESPRESSE I N mm
PARAPETTO DI ALTEZZA
1200mm POSTO A
PROTEZI ONE DELLA FOSSA
I N ACCORDO CON LA
NORMA SN EN I SO 14122-3
LAMI ERA ZI NCATA A CALDO
ANTI SCI VOLO,BUGNATA CON
RI LI EVO TI PO "MANDORLATO"
FOSSA REALI ZZATA
I N CALCESTRUZZO
ARMATO
PROTECTI ON PI T
AUTOMATI C GATE WI TH
ELECTROMECANI CAL AND
HOMOLOGATED LOCK
ROLLI NG AUTOMATI C
DOOR 400X450mm
AUTOMATI C SECTI ONAL DOOR
WI TH CEI LI NG ENCUMBER
160- 220mm
HOT GALVANI ZED STEEL PLATE,
MOD. ANTI SKI D
PI T PROTECTI ON h 1200mm BY
LAW SN EN I SO 14122- 3
PI T REALI ZED I N
REI NFORCED CONCRETE
VERSI ONE
VERSI ON
PROFONDI TA
FOSSA
PI T DEPHT
DI MENSI ONI FOSSA
PI T DI MENSI ONS
LARGH.
WI DTH
LUNGH.
LENGHT
F
A B
DI MENSI ONI PI ANALE
PLATFORM DI MENSI ONS
LARGH.
WI DTH
C
LUNGH.
LENGHT
D
CORSA
* E
STROKE
PORTATA
CAPACI TY
PESO
WEI GHT
TENSI ONE
VOLTAGE
STANDARD
LARGO
EXTRALARGO
2500
2600
2700
5360*
5360*
5360*
2440
2540
2640
5300*
5300*
5300*
3000- 3500*
3000- 3500*
3000- 3500*
2500
2500
2500
2800
2900
3000
220-380 volt
220-380 volt
220-380 volt
CORSA 3500 mm = LA LUNGHEZZA NECESSARI A PER LA FOSSA DEVE ESSERE DI 5500mm ( PI ANALE 5440mm)
650
650
650
TERMI NARE I L PARAPETTO PERI METRALE 100mm PRI MA
DEL FI LO DELLA FOSSA PER I NSTALLAZI ONE CANCELLO
100
ENDI NG THE LATERAL WALLS 100mm
BEFORE THE PI T EDGE
POSSI BI LI SOLUZI ONI
SOME POSSI BLE SOLUTI ONS
C0|00^ 30|OZ0|c 0^ O3^|c 0O^|00 |'c|1|^1^ c |'O3C1^
0^| |0|1^O10 30|0 0||031c. 0c^|c ^|Cc |c| C^30 v
3^ |^ |cCc331^ 0 O|^ 00||^ O3C1^ ^| |^|0 |1c||^10.
30|OZ0|c 0c^|c | U|^00 0 C0||c||c ^||'||^|10 O|^
101^|c |3c|v^1cZZ^ U^|^|1c|10 O|^ 101^|c ||01cZ0|c.
30|OZ0|c 31O0^1^ |^' 00vc v 3^ |^ |cCc331^ 0 ^vc|c
O| |^33^UU0 |3c|0 | c|1|^|3c |c 0|cZ0| ^| |^|0
1c||^.
011|^ 30|OZ0|c | U|^00 0 cv1^|c |U0|3| c31c||
00vO1 ^||'^|c|1O|^ 0c||c ^|1c 0 O| C|^33C0 C^|Cc||0
CONVENI ENT SOLUTI ON TO BE USED WHEN CAR LI FT ENTRY
AND EXI T ARE OPPOSI TE. I T' S I DEAL ALSO I F I T' S REQUI RED A
DOUBLE EXI T AT THE LOWER FLOOR.
CONVENI ET SOLUTI ON ABLE TO GI VE TO THE STRUCTURE A COMPLETE
PRI VACY AND TO ASSURE A TOTAL PROTECTI ON TOO
PLANNED SOLUTI ON WHERE THERE I S THE NECESSI TY TO HAVE GOT A FREE
TRANSI T I N BOTH DI RECTI ON AT THE GROUND LEVEL
OPTI MAL SOLUTI ON TO AVOI D EXTERNAL ENCUMBERED CAUSED TO THE
SPREAD OF THE CLASSI C GATE SHUTTERS .
GREEN PARK SRL - VI A DEI COLLI n30 - 25013 CARPENEDOLO ( BS) - TEL.030/ 9698822 FAX 030/ 969303
www. greenparksrl.it mail: inf o@gr eenpar ksrl.it
6
0
0
4
5
0
0O^0|0 c|c11|C0
7
5
0
2
5
0
5
0
0
1
0
0
0
MOTORE TI PO
POTENZA
( HP) ( kW)
TENSI ONE ELETTRI CA GI RI MOTORE
( g/ 1' )
ASSORB. SPUNTO
cent ralina
3 4 220 Volt
1400 16- 18 12- 14
cent ralina
cent ralina
3 4
5.5 4
380 Volt
380 Volt
1400
1400
11.5
14.5
6- 7
9- 10
( V) ( A)
UNI T
KI ND OF ENGI NE
POWER
ELECTRI C VOLTAGE ENGI NE RMP STARTI NG ABSORP. FUNCTI ONI NG ABSORP.
UNI T
UNI T
c|cc1-ic eot-o
POSI ZI ONAMENTO VANO TECNI CO E PORTE AI PI ANI
TECHNI CAL COMPARTMENT POSI TI ONI NG AND LANDI NG DOORS
( A)
ASSORB. A REGI ME
C^|Cc||0 C0| ^O10|^13|0 c
3c||^1O|^ |cCC^|C^ 0|0|0U^1^
tu1ont1ico ct1c Wi1 ncctict| to
ono|oct1co |ocr
1O3^Z0|c 000nn |c|
C0||cU^|c|10
v^|0 1cC|C0 v^|0 C0|3^
cocc1io ic, oitnc1c- 0nn,
-on 1c 1ccict| cont-1nc1
1o 1c |i1 st1
|^|^|c110 ^ ||01cZ0|c
0c||^ |033^ |03Z0|^1^
^ ||0 0c||^ 31c33^
-o1cc1ivc Wt|| iis
Wi1 1c i1
|O|3^|1c|^ 0 C0|^|00
|03Z0|^1^
^0 200nn 0^ 1c||^
co1-o| tc| |tcco t1
.20nn -on 1c c-ouo
|0|1^ 3cZ0|^|c C0|
|U0|3|0 30||110 0-220nn
scc1iot| ooo- Wi1 0-220nn
cci|ic vo|unc
|O|3^|1c|^ 0 C0|^|00
|03Z0|^1^
^0 200nn 0^ 1c||^
co1-o| tc| |tcco t1
.20nn -on 1c c-ouo
PI ANO I NTERRATO: POS. PORTA SEZI ONALE
1c|^0 0 3031cU|0 C0||0310
0^ |0|1^|1 c vc|c11^ |c|
3031c|c|c |^ |0|1^ 3cZ0|^|c
|033^
|.3. 1c|||^|c |O| |^1c|^| | ||c^
C0| | ||0 0c||^ |033^
LA GREEN PARK SRL FORNI RA' AL CLI ENTE TUTTI GLI SCHEM I NECESSARI PER LA PREDI SPOSI ZI ONE I N OPERA DELLE TUBAZI ONI CORRUGATE UTI LI PER I L
COLLEGAM ENTO TRA I VARI AUTOM ATI SM I E LA ZONA CENTRALI NA.
Cc|1|^||^ 0|^O|C^ C0||0||c ^||c |0||c
0c||^ 0|c11v^ |^CC|c 200 /2 Cc
0O^0|0 |^CC|^ C0||0||c ^||^
|0||^ Cc-c| 0/9- Cc 7-
UO0^ 0c||^ |0|1^ 3cZ0|^|c
|33^1^ ^| 1c|^0 0 3031cU|0
|^|c 0| 1c 3cC10|^| 000|
|`c0 10 1c 3O||0|1 ||^|c
3O||0|1 ||^|c C0||03c0 3Y ^
0|Z0|1^| 31cc| ||^1c ^|0 1w0
|0313 10 3O||0|1 1c 3cC10|^|
000|
|1
|.3. c|0|U 1c 30cw^||3 ||3 w1 1c
|1
LOWER LEVEL: SECTI ONAL DOOR
GREEN PARK SRL SUPPLI ES ALL THE DRAWI NGS NECESSARY TO PREDI SPOSE THECORRUGATED PI PE-LINE USEFUL FOR THE CONNECTION
BETWEEN AUTOM ATISM AND THE POWER ZONE
Y0|^O|C O|1 | ^CC0|0|U w1 1c
|^w 200 /2 Cc
c|cC1|C^| 30^|0 | ^CC0|0|U w1 1c
|^w Cc c| 0/9- Cc 7-
|^|UcZZ^ 9bnn
^|1cZZ^ 80nn
3|c330|c 80nn
WIDTH
HEIGHT
THICKNESS
GREEN PARK SRL - VI A DEI COLLI n30 - 25013 CARPENEDOLO ( BS) - TEL.030/ 9698822 FAX 030/ 969303
www. greenparksrl.it mail: inf o@gr eenpar ksrl.it
PI ANO TERRA: POSI ZI ONE DEL CANCELLO
C0|0||^ 0 3031cU|0 0c 3^11c|1.1c|||^|c | |^|^|c110
|c||c1|^|c 00nn |||^ 0c| ||0 0c||^ |033^
C^|Cc||0 CO30 ^ ||0
0c| v^|0
||0 |1c||0
0c| v^|0
3O11c| C0|O||3. 1c |^|^|c1|C |^|^|c1
|O31 3c c|0c0 00nn 3c|0|c 1c |1 c0Uc
C|03c0 U^1c | ||c w1 1c
c`1|c|c |1'3 c0Uc
|1c||^| |1'3 c0Uc
GROUND LEVEL: GATE' S POSI TI ON
STANDARD
Le seguent i quot e sono riferit e al modello CMC COVER B1FREE LI GHT largo
5360
2
6
0
0
8
0
0
2600
6
5
0
|O|1 0'^||0UU0 |
Cc|c|10 ^||^10
| |0|00 0c||^ |033^ |O0' c33c|c |c^|ZZ^10
C0| O| |^|0 O||0||c 0 C^|Cc31|OZZ0
^||^10 C0|||c1^|c|1c ||v0 0 |c|0c|Z^,
0||O|c |3|c11^|00 0Oc |O|1 0'^||0UU0
|^||UO|^1 |c||^ v31^ | |^|1^.
U|U|^ 0 |^CC0|1^
^C0O^ |0v^|^
nn b00xb00
|0ZZc11 0 |^CC0|1^
^C0O^ |0v^|^
N1
SEZI ONE FRONTALE
The follwing amount s r elat e t o t he CMC COVER B1FREE LI GHT large model
-tiWt1c- co||cc1io c-io
mm 500x500
|c||0|Cc0 C0|C|c1c
|O|C|O|3
|^|w^1c|
C0||cC10| wc||
THE BOTTOM OF THE PIT CAN BE PRODUCED USING A
HOMOGENEUS CONCRETE PLATFORM WITHOUT SLOPE, OR
RESPECTING TWO FULCRUMS AS SPECIFIED IN THE MAP VIEW
N1
8
0
0
SOLLECI TAZI ONI ED ANCORAGGI
STRESSES AND FASTENERS
LARGO
EXTRALARGO
N1
N1
N1
30 kN 3000 Kg
32 kN 3200 Kg
34 kN 3400 Kg
FRONTAL VI EW
VI STA I N PI ANTA
MAP VI EW
800
800 800
|O|1 0'^||0UU0 0c|
|^|10U|^|0 0^
|c^|ZZ^|c ||v 0
|c|0c|Z^
|c^|ZZ^|c |^ |^3C^ Cc|1|^|c 0c||^ |033^
|cUUc||c|1c | |c|0c|Z^ |c| |c||c11c|c |0 3C0|0
0c||'^C0O^ |0v^|^ ^||'|1c||0 0c| |0ZZc110 0
|^CC0|1^
CARI CHI STRESSES
SUPPORT POIN TS OF THE
PAN TOGRAPH MUST BE
REALIZED WITHOUT SLOPE
REALIZE THE CEN TRAL AREA OF THE PITE WITH A MINIMAL SLOPE TO
ALLOW THE DRAIN AGE OF THE WATER IN THE RAIN WATER COLLECTION
GREEN PARK SRL - VI A DEI COLLI n30 - 25013 CARPENEDOLO ( BS) - TEL.030/ 9698822 FAX 030/ 969303
www. greenparksrl.it mail: inf o@gr eenpar ksrl.it
FORNI RE UNA ADEGUATA ILLUM I NAZI ONE SU ENTRAM BI I PI ANI DI CARICO IN M ODO DA OTTENERE UNA
BUONA VISIONE DELLE M ANOVRA DI M OVI M ENTAZIONE
PULSANTIERE DI COM ANDO A TENUTA STAGNA, POSIZIONATE ALL' ESTERNO DELLA M ACCHINA IN POSIZIONE
FAVOREVOLE AD UN CONTROLLO DELLE M ANOVRE DI M OVIM ENTAZI ONE, COM PLETE DI LAM PEGGIANTE
CON PULSANTI LUM I NOSI DI SEGNALAZIONE PIANI , CHIAVE ESTRAIBILE E PULSANTE DI EM ERGENZA.
LE PROTEZIONI AI PI ANI SONO DOTATE DI SERRATURA ELETTROM ECCANICA OM OLOGATA
SEZIONATORE GENERALE DI ALI M ENTAZIONE ELETTRI CA M UNITO DI DISPOSI TI VO DI CHIUSURA PER IM PEDIRE
L' AZI ONAM ENTO DA PARTE DI PERSONALE NON AUTORIZZATO.
DATI TECNI CI
TECNI CAL DETAI LS
MONTAUTO: DI SPOSI TI VI DI SI CUREZZA PRESENTI
VANO MONTAUTO: DI SPOSI TI VI DI SI CUREZZA PRESENTI
PARAPETTO I N ACCI AI O O IN M URATURA DI ALTEZZA NON I NFERIORE AD 1200mm POSIZIONATO A FILO
DELLA FOSSA.
PIANALE RIVESTI TO I N LAM I ERA ZI NCATA A CALDO STRI ATA O BUGNATA CON RILIEVO TIPO " M ANDORLATO" .
VALVOLE DI TENUTA M ONTATE DIRETTAM ENTE SUI M ARTINETTI DI SPINTA.
TUBAZIONI I N ACCI AI O CATEGORIA R2.
VALVOLA DI M ASSIM A PRESSI ONE PER SOVRACCARICHI.
VALVOLA DI BLOCCO CONTRO IL RISCHIO DI ROTTURA CIRCUITO IDRAULICO.
I M PIANTO ELETTRICO IN BASSA TENSI ONE (24 VOLT) CON FUNZIONAM ENTO AD " UOM O PRESENTE" .
DISPOSI TI VO M ECCANI CO DI SI CUREZZA PER M ANUTENZIONI.
POSSI BI LI FI NI TURE SUL PI ANALE
POSSI BLE FI NI SHES ON THE PLATFORM
PLATFORM COVERED BY A STRIPED OR SKEPPED FLOOR, BOTH HOT DEEP GALVANIZED
ELECTRICAL WIRING IN LOW TENSION 24V WITH FUNCTIONING WITH DEAD M AN SWITCH.
STEEL PIPES OF R2 CATEGORY
M ECHANICAL SAFETY DEVICE USED DURING THE M AINTENANCE
LOCKING VALVE AGAINST THE RISK OF HYDRAULIC CIRCUIT DEM AGES
M AXIM AL PRESSION VALVE REQUIRED FOR OVERLOAD
SAFETY VALVE FIXED DIRECTLY ON THE CYLINDERS
PARAPET M ADE IN STEEL OR IN CONCRETE WITH A HEIGHT OF 1200mm POSITIONATED FINISH WITH THE PIT
WATERTIGHT CONTROL PANELS , PLACED OUTSIDE OF THE M ACHINE IN FAVOURABLE POSITIONG TO HAVE A GOOD CONTROL OF THE
HANDLING OPERATIONS; IT HAS GOT FLASHING INDICATORS, EM ERGENCY BUTTON REM OVABLE KEY
PROTECTIONS AT THE FLOORS WITH HAVE GOT AN ELECTRICAL HOM OLOGATED LOCK.
GENERAL ELECTRICITY SWITCH WITH A CLOSING DEVICE TO PREVENT OPERATION BY UNAUTHORIZED PEOPLE
ADEQUATE ILLUM INATION IS REQUIRED AT BOTH FLOOR. TO SEE VERY WELL ALL THE M ANOUVRES
RESISTENTE ED ELEGANTE, OFFRE IL
M ASSI M O DEL COM FORT E SI ABBINA
M ERAVIGLI OSAM ENTE CREANDO
UN' OASI SIM BI OTICA CON L' AM BI ENTE
CIRCOSTANTE
I L PVC VI ENE IM PI EGATO PER
RIVESTI RE I PIANALI GREENPARK
POI CHE CONSENTE DI REALIZZARE
QUALSIASI TIPO DI DESI GN CON UN
PESO RI DOTTO E UNO SPESSORE
M INIM O (mi n. 5mm - max 25mm)
QUESTO M ATERI ALE INNOVATI VO SI
PRESTA BENI SSIM O AL RIVESTI M ENTO
DEI PIANALI GREENPARK
CONFERENDO LORO UN ASPETTO
RISPETTOSO DELL' AM BIENTE OVE
I NSERITO
LA GRIGLIA D' AREAZIONE COLLOCATA
IN M ODO PARZIALE O TOTALE SUL
PIANALE, OFFRE A QUESTA SOLUZIONE,
GRAZIE ALL' ELEVATA DIFFUSIONE
DELLA LUM INOSITA E DEL RICIRCOLO
D' ARIA, UN VALORE AGGIUNTO.
PVC IS EM PLOYED TO COVER GREENPARK'S
PLATFORM S BECAUSE YOU CAN REALIZED WITH
IT EVERY KIND OF SOLUTION ALSO WITH ITS
REDUCED WEIGHT AND M INIM UM THICKNESS
HIGH RESISTANT AND ELEGANT SOLUTION TO
COVER OUR PLATFORM RESPECTING THE
ENVIRONM ENT
THIS INNOVATE M ATERIAL IS ONE OF THE BEST
SOLUTION TO RESPECT THE ENVIRONM ENT
WHERE THE CARLIFT IS POSITIONATED
VENTILATION GRID APPLIED TOTALLY OR
PARTIAL OFFERS HIGH BRIGHTNESS AND
OPTIM AL AREATION
RI VESTI MENTO I N LEGNO RI VESTI MENTO I N PVC RI V. I N ERBA SI NTETI CA PI ANALE GRI GLI ATO
STOPPAGE WHEELS USED FOR POSITIONATED CORRECTLY THE CAR ON THE PLATFORM
FERM ARUOTA M ECCANICO PER CORRETTO POSI ZI ONAM ENTO DELLA VETTURA
GREEN PARK SRL - VI A DEI COLLI n30 - 25013 CARPENEDOLO ( BS) - TEL.030/ 9698822 FAX 030/ 969303
www. greenparksrl.it mail: inf o@gr eenpar ksrl.it
ALCUNE DELLE NOSTRE REALI ZZAZI ONI
GREEN PARK SRL - VI A DEI COLLI n30 - 25013 CARPENEDOLO ( BS) - TEL.030/ 9698822 FAX 030/ 969303
www. greenparksrl.it mail: inf o@gr eenpar ksrl.it
SOME OF OUR WORKS

Potrebbero piacerti anche