Sei sulla pagina 1di 4

INCARCARI GRAVITATIONALE: TERASA CIRCULABILA

1.Planseu b.a. 0.14 25 3.5 1.35 4.725


2.Sapa egalizare 0.03 21 0.63 1.35 0.8505
3.Bariera de vapori - 0.01 0.01 1.35 0.0135
5.Sapa slab armata 0.03 21 0.63 1.35 0.8505
6.Hidroizolatie - 0.04 0.04 1.35 0.054
7.Sapa adeziv 0.03 14.2 0.426 1.35 0.5751
8.Gresie ceramica 0.015 11 0.165 1.35 0.22275
PERMANENTE 5.416 7.312
9.Utila - - 2 1.05 2.1
10.Zapada - - 1.2 1.5 1.8
VARIABILE 3.9
INCARCARI 11.212
VALOAREA
DE CALCUL
[KN/m
2
]
TIP INCARCARE
GROSIME
STRAT [m]
[KN/m
3
]
VALOARE
NORMATA
[KN/m
2
]
COEFICIENT
INCARCARII
VARIABILE
PERMANENTE
4.Termoizolatie din polistiren
extrudat
0.02025 1.35 0.015 0.3 0.05
INCARCARI 11.212
VALOAREA DE CALCUL [KN/mp] 11.21
INCARCARI PLANSEU CURENT
1.Planseu b.a. 0.14 25 3.5 1.35 4.725
2.Sapa slab aramta 0.03 21 0.63 1.35 0.8505
3.Gresie ceramica 0.015 11 0.165 1.35 0.22275
4.Tencuiala 0.025 19 0.475 1.35 0.64125
PERMANENTE 4.77 6.4395
5.Pereti despartitori 15-20cm - - 0.5 1.35 0.675
6.Utila - - 3 1.05 3.15
VARIABILE 3.825
INCARCARI 10.2645
VALOAREA DE CALCUL [KN/mp] 10.26
TIP INCARCARE
GROSIME
STRAT [m]
[KN/m
3
]
VALOARE
NORMATA
[KN/m
2
]
COEFICIENT
INCARCARII
VALOAREA
DE CALCUL
[KN/m
2
]
PERMANENTE
VARIABILE (cvasipermanente)
VARIABILE
PERETI EXT/INT 35cm H = 3.1 m
1.Tencuiala 0.025 19 1.4725 1.35 1.987875
2.B.C.A. 0.3 9.5 8.835 1.35 11.92725
3.Tencuiala 0.025 19 1.4725 1.35 1.987875
PERMANENTE 15.903
PERETI INTERIORI 25cm H = 3.1 m
1.Tencuiala 0.025 19 1.4725 1.35 1.987875
2.B.C.A. 0.2 9.5 5.89 1.35 7.9515
3.Tencuiala 0.025 19 1.4725 1.35 1.987875
PERMANENTE 11.93
TIP INCARCARE
GROSIME
STRAT [m]
[KN/m
3
]
VALOARE
NORMATA
[KN/m]
COEFICIENT
INCARCARII
VALOAREA
DE CALCUL
[KN/m]
PERMANENTE
PERMANENTE
TIP INCARCARE
GROSIME
STRAT [m]
[KN/m
3
]
VALOARE
NORMATA
[KN/m]
COEFICIENT
INCARCARII
VALOAREA
DE CALCUL
[KN/m]
PERMANENTE 11.93
Greutate Atic = 0.50x0.30*25 = 3.75 KN/m
Gatic x coeficient G.F.=3.75x1.35= 5.06 KN/m
PREDIMENSIONARE ELEMENTE STRUCTURALE :
Predimensionarea placii:
h
placa
=h*P/180 +2cm = (5.80x2+5.20x2)/180+0.02 = 0.14 m
P=perimetrul maxim intalnit la un ochi de placa
h = inaltimea minima de placa
Inaltimea placii se va alege = 0.14 m = 14 cm
Predimensionarea grinzii
La grinzile din beton armat monolit, dimensiunile seciunii transversale se adopt, de regul,
multiplu de 50mm pentru i multiplu de 100mm pentru h 80cm
Hgr long = L/(8..12) = 600/10 = 60 cm
Hgr trasn = l/(812) = 550/10 55 cm
unde :
L =deschiderea
l =traveea
Inaltimea grinzii longit. bgr = Hgr/2 = 60/2 = 30 cm
Inaltimea grinzii transv bgr = Hgr/2=55/2 = 27.5 cm
Voi alege urmatoarele dimensiuni pentru grinzile structurii:
Pentru deschidere voi considera grinda cu dimensiunile : 60 x 30 cm
Pentru traveea voi considera grinda cu dimensiunile : 55x30cm
Predimensionarea stalpilor: -voi presupune latura stalpilor initiala de 30cm
STALP DE COLT
Nst.colt = Nterasa+Nplanseu cr. * 2 + Natic + Npereti ext + Npereti int + Ngreutate proprie
ARIA AFERENTA A STALPULUI = 7.27 mp
Lungimea peretilor ext = 5.27 m
Lungimea aticului = 5.27 m
Nst.colt = 521.64 KN
STALP PERIMETRAL
Nst.perim = Nterasa+Nplanseu cr. * 2 + Natic + Npereti ext + Npereti int + Ngreutate proprie
ARIA AFERENTA A STALPULUI = 15.51 mp
Lungimea peretilor ext = 5.5 m
Lungimea aticului = 5.5 m Lungimea aticului = 5.5 m
Nst.perim = 984.57 KN
STALP CENTRAL
Nst.central = Nterasa+Nplanseu cr. * 2+ Npereti int + Ngreutate proprie
ARIA AFERENTA A STALPULUI = 26 mp
Nst.perim = 1452.45 KN
n = N / (bxhxfcd ) 0.40 => b = h = (N/(nxfcd))
fcd = 13 N/mm2
PTR STALP DE COLT b = h = 0.32 m = 35 cm
PTR STALP PERIMETRAL b = h = 0.44 m = 45 cm
PTR STALP CENTRAL b = h = 0.53 m = 55 cm
Din predimensionare rezulta urmatoarele laturi ale stalpilor :
Stalp de colt : 35 x 35 cm
Stalp perimetral : 45 x 45 cm
Stalp central : 55 x 55 cm
EVALUAREA ZAPEZII
Localitatea unde va fi amplasata constructia : CONSTANTA -> ag = 0.16 g
Valoarea caracteristica a incarcarii data din zapada este data de formula:
sk = i*Ce*Ct*sok = 0.8*1*1*1.5 = 1.2 KN/mp
Ct =coeficient termic, pentru acopersuri cu termoizolatie uzuala = 1
Ce = coeficient de expunere al constructiei = 1 pentru expunere normala
i = coeficient de forma al acoperisului. Pentru 0< < 30 grade -i = 0.8
CALCULUL ELEMENTELOR STRUCTURALE
CALCULUL PLACII
Determinarea momentelor din camp M1 si M2 si din reazem M1' si M2', s-au obtinut conform
relatiilor 3.3.4.1-3.3.4.13 din STAS 10107-2/92
Coeficientii din relatiile de calcul sunt determinate printr-un calcul elastic exact al pacilor,
considerand coeficientul de deformatie transversala al betonului =0.
In prima schema conventionala de rezemare a placilor, panourile se considera incastrate perfect pe
reazemele interediare si simplu rezemate pe conturul planseului. Pe suprafetele tuturor panourilor
aceste scheme se aplica o incarcare gravitationala q1 = ( P+U/2 ) se vor rezulta valorile momentelor
M
1
1
=
1
x q
1
x l
1
2
M
1
= x q x l
2
M
1
2
=
2
x q
1
x l
2
2
In a doua schema conventionala de rezemare a placilor, se considera simplu rezemare pe tot conturul
acestora. Pe suprafetele tuturor placilor se aplica o incarcare conventionala dirijata alternant de sus in
jos si de jos in sus a carei intensitate pe unitatea de suprafata este data de relatia q2 - +- P/2, rezultand
in acest fel , valorile momentelor incovoietoare pe cele doua directii :
M
2
1
=
1
x q
2
x l
1
2
M
2
2
=
2
x q
2
x l
2
2
Momentele maxime si respectiv minime in campuri se obtin prin adunarea momentelor incovoietoare
produse de incarcarea q1 pe prima schema conventionala de rezemare, cu momentele incovoietoare
produse de incarcarea q2 pe a doua schema conventionala de rezemare. In final, valorile momentelor
incovoietoare pe cele doua directii sunt:
M
1
= M
1
1
+ M
2
1
M
2
= M
1
2
+ M
2
2
SCHEMA CONVENTIONALA NR 1.