2.Sapa egalizare 0.03 21 0.63 1.35 0.8505 3.Bariera de vapori - 0.01 0.01 1.35 0.0135 5.Sapa slab armata 0.03 21 0.63 1.35 0.8505 6.Hidroizolatie - 0.04 0.04 1.35 0.054 7.Sapa adeziv 0.03 14.2 0.426 1.35 0.5751 8.Gresie ceramica 0.015 11 0.165 1.35 0.22275 PERMANENTE 5.416 7.312 9.Utila - - 2 1.05 2.1 10.Zapada - - 1.2 1.5 1.8 VARIABILE 3.9 INCARCARI 11.212 VALOAREA DE CALCUL [KN/m 2 ] TIP INCARCARE GROSIME STRAT [m] [KN/m 3 ] VALOARE NORMATA [KN/m 2 ] COEFICIENT INCARCARII VARIABILE PERMANENTE 4.Termoizolatie din polistiren extrudat 0.02025 1.35 0.015 0.3 0.05 INCARCARI 11.212 VALOAREA DE CALCUL [KN/mp] 11.21 INCARCARI PLANSEU CURENT 1.Planseu b.a. 0.14 25 3.5 1.35 4.725 2.Sapa slab aramta 0.03 21 0.63 1.35 0.8505 3.Gresie ceramica 0.015 11 0.165 1.35 0.22275 4.Tencuiala 0.025 19 0.475 1.35 0.64125 PERMANENTE 4.77 6.4395 5.Pereti despartitori 15-20cm - - 0.5 1.35 0.675 6.Utila - - 3 1.05 3.15 VARIABILE 3.825 INCARCARI 10.2645 VALOAREA DE CALCUL [KN/mp] 10.26 TIP INCARCARE GROSIME STRAT [m] [KN/m 3 ] VALOARE NORMATA [KN/m 2 ] COEFICIENT INCARCARII VALOAREA DE CALCUL [KN/m 2 ] PERMANENTE VARIABILE (cvasipermanente) VARIABILE PERETI EXT/INT 35cm H = 3.1 m 1.Tencuiala 0.025 19 1.4725 1.35 1.987875 2.B.C.A. 0.3 9.5 8.835 1.35 11.92725 3.Tencuiala 0.025 19 1.4725 1.35 1.987875 PERMANENTE 15.903 PERETI INTERIORI 25cm H = 3.1 m 1.Tencuiala 0.025 19 1.4725 1.35 1.987875 2.B.C.A. 0.2 9.5 5.89 1.35 7.9515 3.Tencuiala 0.025 19 1.4725 1.35 1.987875 PERMANENTE 11.93 TIP INCARCARE GROSIME STRAT [m] [KN/m 3 ] VALOARE NORMATA [KN/m] COEFICIENT INCARCARII VALOAREA DE CALCUL [KN/m] PERMANENTE PERMANENTE TIP INCARCARE GROSIME STRAT [m] [KN/m 3 ] VALOARE NORMATA [KN/m] COEFICIENT INCARCARII VALOAREA DE CALCUL [KN/m] PERMANENTE 11.93 Greutate Atic = 0.50x0.30*25 = 3.75 KN/m Gatic x coeficient G.F.=3.75x1.35= 5.06 KN/m PREDIMENSIONARE ELEMENTE STRUCTURALE : Predimensionarea placii: h placa =h*P/180 +2cm = (5.80x2+5.20x2)/180+0.02 = 0.14 m P=perimetrul maxim intalnit la un ochi de placa h = inaltimea minima de placa Inaltimea placii se va alege = 0.14 m = 14 cm Predimensionarea grinzii La grinzile din beton armat monolit, dimensiunile seciunii transversale se adopt, de regul, multiplu de 50mm pentru i multiplu de 100mm pentru h 80cm Hgr long = L/(8..12) = 600/10 = 60 cm Hgr trasn = l/(812) = 550/10 55 cm unde : L =deschiderea l =traveea Inaltimea grinzii longit. bgr = Hgr/2 = 60/2 = 30 cm Inaltimea grinzii transv bgr = Hgr/2=55/2 = 27.5 cm Voi alege urmatoarele dimensiuni pentru grinzile structurii: Pentru deschidere voi considera grinda cu dimensiunile : 60 x 30 cm Pentru traveea voi considera grinda cu dimensiunile : 55x30cm Predimensionarea stalpilor: -voi presupune latura stalpilor initiala de 30cm STALP DE COLT Nst.colt = Nterasa+Nplanseu cr. * 2 + Natic + Npereti ext + Npereti int + Ngreutate proprie ARIA AFERENTA A STALPULUI = 7.27 mp Lungimea peretilor ext = 5.27 m Lungimea aticului = 5.27 m Nst.colt = 521.64 KN STALP PERIMETRAL Nst.perim = Nterasa+Nplanseu cr. * 2 + Natic + Npereti ext + Npereti int + Ngreutate proprie ARIA AFERENTA A STALPULUI = 15.51 mp Lungimea peretilor ext = 5.5 m Lungimea aticului = 5.5 m Lungimea aticului = 5.5 m Nst.perim = 984.57 KN STALP CENTRAL Nst.central = Nterasa+Nplanseu cr. * 2+ Npereti int + Ngreutate proprie ARIA AFERENTA A STALPULUI = 26 mp Nst.perim = 1452.45 KN n = N / (bxhxfcd ) 0.40 => b = h = (N/(nxfcd)) fcd = 13 N/mm2 PTR STALP DE COLT b = h = 0.32 m = 35 cm PTR STALP PERIMETRAL b = h = 0.44 m = 45 cm PTR STALP CENTRAL b = h = 0.53 m = 55 cm Din predimensionare rezulta urmatoarele laturi ale stalpilor : Stalp de colt : 35 x 35 cm Stalp perimetral : 45 x 45 cm Stalp central : 55 x 55 cm EVALUAREA ZAPEZII Localitatea unde va fi amplasata constructia : CONSTANTA -> ag = 0.16 g Valoarea caracteristica a incarcarii data din zapada este data de formula: sk = i*Ce*Ct*sok = 0.8*1*1*1.5 = 1.2 KN/mp Ct =coeficient termic, pentru acopersuri cu termoizolatie uzuala = 1 Ce = coeficient de expunere al constructiei = 1 pentru expunere normala i = coeficient de forma al acoperisului. Pentru 0< < 30 grade -i = 0.8 CALCULUL ELEMENTELOR STRUCTURALE CALCULUL PLACII Determinarea momentelor din camp M1 si M2 si din reazem M1' si M2', s-au obtinut conform relatiilor 3.3.4.1-3.3.4.13 din STAS 10107-2/92 Coeficientii din relatiile de calcul sunt determinate printr-un calcul elastic exact al pacilor, considerand coeficientul de deformatie transversala al betonului =0. In prima schema conventionala de rezemare a placilor, panourile se considera incastrate perfect pe reazemele interediare si simplu rezemate pe conturul planseului. Pe suprafetele tuturor panourilor aceste scheme se aplica o incarcare gravitationala q1 = ( P+U/2 ) se vor rezulta valorile momentelor M 1 1 = 1 x q 1 x l 1 2 M 1 = x q x l 2 M 1 2 = 2 x q 1 x l 2 2 In a doua schema conventionala de rezemare a placilor, se considera simplu rezemare pe tot conturul acestora. Pe suprafetele tuturor placilor se aplica o incarcare conventionala dirijata alternant de sus in jos si de jos in sus a carei intensitate pe unitatea de suprafata este data de relatia q2 - +- P/2, rezultand in acest fel , valorile momentelor incovoietoare pe cele doua directii : M 2 1 = 1 x q 2 x l 1 2 M 2 2 = 2 x q 2 x l 2 2 Momentele maxime si respectiv minime in campuri se obtin prin adunarea momentelor incovoietoare produse de incarcarea q1 pe prima schema conventionala de rezemare, cu momentele incovoietoare produse de incarcarea q2 pe a doua schema conventionala de rezemare. In final, valorile momentelor incovoietoare pe cele doua directii sunt: M 1 = M 1 1 + M 2 1 M 2 = M 1 2 + M 2 2 SCHEMA CONVENTIONALA NR 1.