Portata massima 100 m3/h 130 m3/h 250 m3/h 400 m3/h 600 m3/h
Max flow rate 440 US gpm 573 US gpm 1100 US gpm 1760 US gpm 2640 US gpm
Area filtrante 1500 cm2 2200 cm2 3300 cm2 5400 cm2 6800 cm2
Screen area 235 in2 345 in2 520 in2 840 in2 1100 in2
Pressione minima
2 bar (29 psi)
Min working pressure
Pressione massima
10 bar (145 psi) - *16 bar (232 psi)
Max working pressure
Temperatura massima
60°C (140°F)
Max working temperature
Salinità
< 10.000 ppm TDS
Salinity
Acidità
pH 3 ÷ 9
Acidity
Valvola di scarico
1”½ BSPP 1”½ BSPP 2” BSPP 2” BSPP 2” BSPP
Drain valve
Avvio del ciclo di pulizia Pressione differenziale (0.8 bar, Regolabile), intervalli di tempo, manualmente
Flushing criteria Differential pressure (0.8 bar, Adjustable), time intervals and manual operation
Rete Cartuccia sandwich con maglia filtrante in poliestere - Cartuccia REPS triplo strato (AISI 316)
Screen types Sandwich cartridge with polyester inner mesh - REPS cartridge triple layer (AISI 316)
Guarnizioni cartuccia
EPDM
Cartridge gaskets
Alimentazione
230 Vac 50/60Hz
Rated operation voltage
Voltaggio di comando
24 Vdc
Control voltage
Motore
Elettrico o Idraulico - Electric or Hydraulic
Motor
MATERIALI - MATERIALS
Corpo filtro
304 SS / 316 SS / DUPLEX 2205
Filter body
Coperchio
304 SS / 316 SS / DUPLEX 2205
Cover
Supporto rete
304 SS / 316 SS / DUPLEX 2205
Screen support
Guarnizioni
EPDM
Gasket
3 [US gpm] A B C D E X
[m /h]
VTO L 2"/10A 2” BSPP 1”½ BSPP 1500 235 40 176 535 980 296 203 206 500 25
VTO L 3"/10A 3” BSPP 1”½ BSPP 1500 235 80 352 535 980 296 203 206 500 25
VTO L 100/10A DN100 1”½ BSPP 1500 235 100 440 535 1025 346 203 206 500 31
VTO L 100/20 DN100 1”½ BSPP 2200 345 130 572 535 1180 346 203 206 650 34
VTO L 100/35 DN100 2” BSPP 3300 520 140 616 580 1180 346 236 273 650 42
VTO L 150/35 DN150 2” BSPP 3300 520 250 1100 580 1180 346 236 273 650 46
VTO L 150/40P DN150 2” BSPP 3300 520 300 1320 580 1490 346 236 273 1000 54
VTO L 200/40P DN200 2”BSPP 5400 840 400 1760 580 1490 366 236 273 1000 67
VTO L 200/50 DN200 2” BSPP 6800 1100 450 1980 580 1650 366 236 273 1280 82
VTO L 250/50 DN250 2” BSPP 6800 1100 550 2420 580 1650 383 290 323 1280 92
Model
In/Out Drain
2 2
Weight
[kg]
Configurazione - Shape O
[cm ] [in ] 3
[m /h] [US gpm] A B C D E X Y
VTO O 2"/10A 2” BSPP 1”½ BSPP 1500 235 40 175 1325 500 450 213 206 500 650 38
VTO O 3"/10A 3” BSPP 1”½ BSPP 1500 235 80 350 1325 500 450 213 206 500 650 39
VTO O 100/10A DN100 1”½ BSPP 1500 235 100 440 1325 500 450 213 206 500 650 44
VTO O 3”/20 3” BSPP 1”½ BSPP 2200 345 80 350 1325 500 450 213 206 650 500 40
VTO O 100/20 DN100 1”½ BSPP 2200 345 130 570 1325 500 450 213 206 650 500 45
VTO O 100/35 DN100 2” BSPP 3300 520 140 620 1790 540 640 246 273 650 1000 68
Y
VTO O 150/35 DN150 2” BSPP 3300 520 250 1100 1790 540 640 246 273 650 1000 73
VTO O 150/40P DN150 2” BSPP 5400 840 300 1320 1790 540 640 246 273 1000 650 74
VTO O 200/40P DN200 2” BSPP 5400 840 400 1760 1790 540 640 286 273 1000 650 85
VTO O 200/50 DN200 2” BSPP 6800 1100 450 1980 1990 540 670 286 273 1000 650 88
VTO O 250/50 DN250 2” BSPP 6800 1100 550 2420 2010 600 670 317 324 1000 650 115
VTO O 300/50 DN300 2” BSPP 6800 1100 600 2640 2010 650 670 317 355 1000 650 148
Screen Area
Model Qmax* Dimensioni - Dimensions [mm] Peso
Weight
Configurazione - Shape Y
In/Out Drain
] [US gpm] A B C D E X
2 2 3 [kg]
[cm ] [in ] [m /h] [US gpm] A B C D E X
VTO Y 2"/10A 2” BSPP 1”½ BSPP 1500 233 40 176 730 790 395 - 206 500 22
VTO Y 3"/10A 3” BSPP 1”½ BSPP 1500 233 80 352 760 800 450 - 206 500 24
VTO Y 100/20 DN100 1”½ BSPP 2200 341 130 572 900 920 550 - 206 650 32
VTO Y 100/35 DN100 2” BSPP 3300 512 140 616 920 930 600 - 273 650 44
VTO Y 150/35 DN150 2” BSPP 3300 512 250 1100 990 950 745 - 273 650 48
VTO Y 150/40P DN150 2” BSPP 5400 837 300 1320 1200 1200 745 - 273 1000 58
*Le portate vengono riferite a filtri con rete filtrante da 120 µm e acqua a 20 °C con NTU < 1.
Flow rates are referred to filters with 120 µm filtrating mesh and water with temperature of 20 °C and NTU < 1.
Perdite di carico riferite a filtri con rete filtrante da 120 µm e acqua pulita
Head losses are referred to filters with 120 µm filtrating mesh and clean water.e of 20 °C and NTU < 1.