Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
AVVISI AMS CONTROLLER IN VOLO SOLO PER DOPPIA AVARIA (CAUTION AMBRA)SENNO A TERRA (BLU)
CONTROL PANEL DARK COCKPIT SE TUTTO FUNZIONA TUTTI I P/B SONO NERI
CONTROL PANEL PER BLEED FAULT (LEAK) SUL P/B AVREMO UNA BARRA AMBRA E BISOGNERA METTERE IMP.SU OFF
190 TUTTI ICOMPONENTI PRINCIPALI PRELEV PNEUM SONO “AVANTI” SUL MOTORE
PRESSURE SENSOR 1 SUL CONDOTTO REGOLA MAX 100 PSI SEGNALE A RELAY RIT 3” CHIUSURA NAPRSOV
170 PRESSURE SENSOR 1 SULLA VALVOLA HPSOV A MONTE PRESS>190 PSI SEGNALE A RELAY CHIUSURA HPSOV
190 PRESSURE SENSOR 1 SULLA LINEA A MONTE VALVOLA HPSOV>190 PSI SEGNALE RELAY PER CHIUSURA HPSOV
I SENSORI DI PRESSIONE 190 PSI SONO MONTATI SUL PILONE
PRESSURIZZAZIONE TANK ACQUA POTABILE 36-41 PSI CON TUBO CON RESTRITTORE DA 1,5 MM
X BLEED VALVE PNEUMATICA COMANDATA DA TORQUE CHE RICEVE SEGNALE DA AMS DOPO 2MINUTI DALL’ATTERRAGGIO SI
POSIZIONA APERTA ON-OFF PER CONTROLLARE IL FUNZIONAMENTO
FAN AIR MODULA PER REGOLARE LA TEMPERATURA DELL IMPIANTO IN FAIL SAFE E OPEN
TORQUE MOTOR PR HPSOV E NAPRSOV PER ENTRAMBE GLI AEREI E NEL PILONE MA NEL 170 I FILTRI DELLE LINEE SONO SUL
CORPO DEL TORQUE MANTRE NEL 190 SONO STATI SPOSTATI SULLE VALVOLE
SENSORE PRESSIONE MANIFOLD SENTE LA PRESSIONE E INVIA IL SEGNALE ALL AMS VALORE NORMALE 45 PSI SONO DIETRO LA
PRIMA SEZIONE SLAT
PRECOOLER REGOLA LA TEMPERATURA TRAMITE LA FAN CONTROL VALVE A 204°C ED IN FUNZIONAMENTO IMPIANTO
ANTIGHIACCIO A 231°C (PER AVARIA CONTROLLA FINO A 259 X 2 MINUTI E 260 X 3 SECONDI)
LA HPSOV FORNISCA LA PRESSIONE ALL IMPIANTO IN CONDIZIONI DI SCARSO FLUSSO DAL MOTORE (HI PRESS) E REGOLA LA
PRESSIONE FINO A QUANDO AUMENTANDO LA PORTATA IL FLUSSO PROVENIENTE DALLA (LO PRESS) SIA SUFFICIENTE DOPODICHE
ANDRA’ IN CHIUSURA E SI APRIRA’ COMPLETAMENTE PER COADIUVARE LA LP IN FLT IDLE CON ANTIGHIACCIO ON OPPURE
PARZIALMENTE SEMPRE CON ANTIGHIACCIO IN ALTRE CONDIZIONI DI VOLO PER AUMENTARE LA TEMPERATURA DELL’ARIA.
CON IMPIANTO ANTIGHIACCIO ON LA FAN VALVE ANDRA IN CHIUSURA COMANDATA DALL AMS TRANNE CHE CON SAI ON E FLT
IDLE DOVE AVENDO LA HP FULL OPEN MODULERA’ SE RICHIESTO LA TEMPERATURA
ANTIGHIACCIO ON SINGLE BLEED LA X FEED APRE PER 5” SE LA PRESSIONE NEL MANIFOLD RESTA <90 PSI RESTA APERTA SENNO
CHIUDE
APU CHK VALVE SUL RACCORDO ALA FUSOLIERA SX FLABELLI CARICATI A MOLLA IN APERTURA (VALVOLA CHIUSA)
APU BLEED VALVE E SULL APU SI APRE QUANDO L’APU FORNISCE ALMENO 13 PSI
I CONDOTTI PNEUMATICI SONO IN SEZIONI UTITE TRAMITE DEI GIUNTI CHAMATI BELLOWS BALL JOINT
L’APU BLEED REQUEST E DETERMINATO DALL AMS CHE INVIA IL COMANDO AL FADEC TRAMITE LO SPDA
BLEED SUPPLY LOGIC RICHIEDE CHE NELL ‘IMPIANTO CI SIANO ALMENO 12 PSI DISPONIBILI
DA 204 A 234°C NORMALE-DA 235 A 259 < 2’NORMALE –DA 235 A 259 >2’SHUT OFF (HPSOV E NAPRSOV)->260°>3” SHUT OFF
AVVISO CAS AMBRA BLEED FAIL (RESETTABILE CON P/B OFF-ON)
OVERHEAT DETECTION 6 CANALI LOOP DOPPI PER 9 ZONE
ILCONTROLLER SONO DELLE SCHEDE ATTACCATE AL PROCESSOR DI OGNI CANALE DELL AMS (SLOT 18 E 25 SPDA 2)
SUL SINOTTICO BIANCO E OFF GREEN E ON E AMBRA E FAIL SOLO TRATTEGGIO POSIZIONE INDETERMINATA TRATTEGGIO CON
CROCE AVARIA INDETERMINATA
ENTRAMBE I CANALI DELLO STESSO LOOP DEVONO REGISTRARE L’ANOMALIA PER GENERARE UN AVVISO CAS IN VOLO
I LOOP DISCRIMINANO UN LEAK CON 2 DIVERSI RANGE DI FUNZ.TO 124°C DENTRO IL PYLON E 154°C FUORI DAL PYLON
L’AVVISO BLEED LEAK AMBRA POTREMO AVERLO PER DOPPIA AVARIA-DOPPIO RILEVAMENTO-SOVRAPRESSIONE>100 PSI
IL SENSORE DI SOVRAPRESSIONE MANIFOLD >100 PSI GENERA ANCHE UN AVVISO CAS BLEED OVERPRESS AMBRA
CROSS BLEED FAIL LINEA SUL PUSHBUTTON SE LA CROSSBLEED NON HA FUNZIONATO ..RITARDATO DI 35” (TEST AFTER LDG)
APU OVERHEAT ..DEVE ESSERE RILEVATA DA 2 SENSORI>124°C O DOPPIA AVARIA ODS AVVISO AMBRA BLEED APU LEAK
OZONE CONVERTERS SERVE PER ELIMINARE L’OZONO CHE PROVIENE DALLE BLEED MOTORI DURANTE IL VOLO AD ALTA
ALTITUDINE E CHE IN DETERMINATE LATITUDINI E TEMPI PROLUNGATI DI VOLO POTREBBE ESSERE NOCIVO.