CERTIFICATO DI COLLAUDO STANDARD PER GRUPPO ELETTROGENO

GENERATING SET STANDARD TEST REPORT

PG1 0 .0 1
ALL. 1 S

COMMESSA/PROJECT ---/-- SN -----

GRUPPO 3F+N STANDARD NEUTRAL grounded (TN) PROTEZIONE DIFFERENZIALE no QUADRO LEXYS AMF
Gen.Set Differential Protection control board

MODEL P D T1 1 6 G 4 kVA 180 COS j 0.8 kW 144

MOTORE/ENGINE GENERATORE/ALTERNATOR
COS TRU T TO RE / M A NUF A CTURE R COS TRU T TO RE / M A NUF A CTURE R
Perkins MECC ALTE

TIP O/ TYP E TIP O/ TYP E


1 1 0 6 C E6 6 TAG4 ECO 38-1SN/4

M ATRI COL A / SN M ATRI COL A / SN

------- ---------

k VA 180 VO LTS 400 Hz 50

DATA/DATE --/--/----- ORA/HOUR --:-- ALT. / HT asl -- m TEMP. -- C

DATI / DATA
% S VOLT AMPERE HERTZ kW CO S PHI
0% 10,0 400, 0 0,0 50,0 0,0 0,0
25% 30,0 400, 0 52,0 50,0 36, 0 1,0
50% 50,0 400, 1 103,9 50,1 72, 0 1,0
75% 70,0 400, 1 155,9 50,1 108,0 1,0
90% 90,0 400, 0 187,1 50,0 129,6 1,0
100% 110, 0 400, 0 207,9 50,0 144,0 1,0
110% 120, 0 400, 0 228,6 50,0 158,4 1,0
40% 130, 0 400, 1 83,1 50,1 57, 6 1,0
0% 140, 0 400, 2 0,0 50,0 0,0 0,0