0 valutazioniIl 0% ha trovato utile questo documento (0 voti)
13 visualizzazioni6 pagine
Low voltage motor feeder equipped with automatic circuit-breaker and contactor
Operable from motor control station and instrumentation control panel - Automatic control -agip
Low voltage motor feeder equipped with automatic circuit-breaker and contactor
Operable from motor control station and instrumentation control panel - Automatic control -agip
Low voltage motor feeder equipped with automatic circuit-breaker and contactor
Operable from motor control station and instrumentation control panel - Automatic control -agip
Documento di propriet aziendale. La Societ tuteler i propri diritti a termini di legge.
Data Compilato Foglio - di
Rev. Agip Sheet - of Compiled Date This document is Company Property. The Company lawfully reserves all rights. 0 NORMALIZZAZIONE INTERNA STANDARDIZATION CODICE Code - - Symbol 20114.EQP.ELE.STD 1 6 F.V. SET. '94 QUADRO BASSA TENSIONE - MOTOR CONTROL CENTER PARTENZA MOTORE B.T. CON INTERRUTTORE E CONTATTORE COMANDO DA COLONNINA E DA QUADRO STRUM. - COMANDO AUTOMATICO LVS758 Low voltage switchboard - Motor control center Low voltage motor feeder equipped with automatic circuit-breaker and contactor Operable from motor control station and instrumentation control panel - Automatic control LEGENDA CODICI APPARECCHIATURE AUSILIARIE Legend codes of auxiliary equipments Q1 CODICE - S2.C/S4.O S3 NOTE - HR HW INTERRUTTORE CIRCUITI AUSILIARI COMANDI E SEGNALAZIONI Red light - Protective relays operated White light - Contactor closed LAMPADA BIANCA - CONTATTORE CHIUSO LAMPADA ROSSA - INTERVENTO PROTEZIONI Notes Description Auxiliary controls and indications circuit-breaker Contactor opening push buttons Contactor closing push button PULSANTI DI APERTURA CONTATTORE PULSANTE DI CHIUSURA CONTATTORE DESCRIZIONE - Codes S6 MANIPOLATORE COMANDO APERTURA-CHIUSURA Start-stop control switch Controls mode selector "switch-off test from switchboard (PC) - Instruments control desk (ICD)" PREDISPOSITORE COMANDI "ESCLUSO-PROVA DA QUADRO (PC) - QUADRO STRUMENTAZIONE (ICD)" S1 LAMPADA BLU - CASSETTO ESTRATTO Blue light - Compartement drawn out HB Control mode selector "switch-instruments control desk (ICD) - Push button station (PBS)" PREDISPOSITORE COMANDO "QUADRO STRUMENTAZIONE (ICD) - COLONNINA (PBS)" S5 HG Green light - User available LAMPADA VERDE - UTENZA DISPONIBILE Documento di propriet aziendale. La Societ tuteler i propri diritti a termini di legge. Data Compilato Foglio - di Rev. Agip Sheet - of Compiled Date This document is Company Property. The Company lawfully reserves all rights. 0 NORMALIZZAZIONE INTERNA STANDARDIZATION CODICE Code - - Symbol SIMBOLO 20114.EQP.ELE.STD 2 6 F.V. SET. '94 QUADRO BASSA TENSIONE - MOTOR CONTROL CENTER PARTENZA MOTORE B.T. CON INTERRUTTORE E CONTATTORE COMANDO DA COLONNINA E DA QUADRO STRUM. - COMANDO AUTOMATICO LVS758 Low voltage switchboard - Motor control center Low voltage motor feeder equipped with automatic circuit-breaker and contactor Operable from motor control station and instrumentation control panel - Automatic control SCHEMA UNIFILARE One line diagram M * If required * QUANDO RICHIESTO PBS S6 A NOTE - 1CK Notes * * S3C HB S4O S5 HW A ICD F49 KM F50 S2O S1 QM 2 3 .......... V .......... V ..... Hz ..... Hz HG HR Q1 1CC 1CS Controls and indications COMANDI E SEGNALAZIONI MCC IP HG HW Documento di propriet aziendale. La Societ tuteler i propri diritti a termini di legge. Data Compilato Foglio - di Rev. Agip Sheet - of Compiled Date This document is Company Property. The Company lawfully reserves all rights. 0 NORMALIZZAZIONE INTERNA STANDARDIZATION CODICE Code - - Symbol SIMBOLO 20114.EQP.ELE.STD 3 6 F.V. SET. '94 QUADRO BASSA TENSIONE - MOTOR CONTROL CENTER PARTENZA MOTORE B.T. CON INTERRUTTORE E CONTATTORE COMANDO DA COLONNINA E DA QUADRO STRUM. - COMANDO AUTOMATICO LVS758 Low voltage switchboard - Motor control center Low voltage motor feeder equipped with automatic circuit-breaker and contactor Operable from motor control station and instrumentation control panel - Automatic control SCHEMA UNIFILARE One line diagram M 1 CT1 * If required * QUANDO RICHIESTO PBS S6 A NOTE - 1CK Notes * * S3C HB S4O S5 HG A ICD F49 KM F50 S2O S1 QM 2 3 .......... V .......... V ..... Hz ..... Hz HG HR A Q1 1CC 1CM 1CS Controls and indications COMANDI E SEGNALAZIONI MCC IP Documento di propriet aziendale. La Societ tuteler i propri diritti a termini di legge. Data Compilato Foglio - di Rev. Agip Sheet - of Compiled Date This document is Company Property. The Company lawfully reserves all rights. 0 NORMALIZZAZIONE INTERNA STANDARDIZATION CODICE Code - - Symbol SIMBOLO 20114.EQP.ELE.STD 4 6 F.V. SET. '94 QUADRO BASSA TENSIONE - MOTOR CONTROL CENTER PARTENZA MOTORE B.T. CON INTERRUTTORE E CONTATTORE COMANDO DA COLONNINA E DA QUADRO STRUM. - COMANDO AUTOMATICO LVS758 Low voltage switchboard - Motor control center Low voltage motor feeder equipped with automatic circuit-breaker and contactor Operable from motor control station and instrumentation control panel - Automatic control SCHEMA LOGICO COMANDI Controls logic diagram APERTO In "out of service" position Tray disconnecting commencement BLOCCO ESTERNO - External lock CHIUSURA MANUALE - APERTURA MANUALE - INIZIO ESTRAZIONE PARTE ESTRAIBILE - -F50 -S1 -QM IN POSIZIONE "FUORI SERVIZIO" - Hand closing Hand opening INTERVENTO - Operated Opened APERTO - MANCANZA TENSIONE COMANDI - -F49 -S6 -S5 -S2O -S4O -S1 In "opened" position INTERVENTO - Operated IN POSIZIONE "APRE" - Controls voltage out In "ICD-PBS" position In "ICD" position IN POSIZIONE "ICD-PBS" - PREMUTO - PREMUTO - Pushed Pushed IN POSIZIONE "ICD" - 1 opened closed CHIUSO APERTO QM opened In "test closure" position CONSENSO ESTERNO - BLOCCO ESTERNO - -KM -S5 -S6 -QM -S1 -F49 In "PBS" position In "closed" position CHIUSO (AUTORITENUTA) - IN POSIZIONE "CHIUDE" - IN POSIZIONE "PBS" - Closed (self retaining) External permission In "ICD" position IN POSIZIONE "ICD" - INTERVENTO - Closed CHIUSO - External lock Operated PARTE ESTRAIBILE IN POS. "PROVA" - -QM -S1 IN POSIZIONE "CHIUSURA PROVA" - Closed CHIUSO - Tray in "test" position closed CHIUSO KM & 1 1 1 1 1 1 1 & & & & & & & IN POSIZIONE "ICD-AUT" - -S5 In "ICD-AUT" position COMANDO AUTOMATICO APERTURA - Automatic opening control COMANDO AUTOMATICO CHIUSURA - Automatic closure control IN POSIZIONE "ICD-AUT" - -S5 In "ICD-AUT" position -S3C PREMUTO - Pushed IN POSIZIONE "ICD-MAN" - -S5 In "ICD-MAN" position Self retaining AUTORITENUTA - Documento di propriet aziendale. La Societ tuteler i propri diritti a termini di legge. Data Compilato Foglio - di Rev. Agip Sheet - of Compiled Date This document is Company Property. The Company lawfully reserves all rights. 0 NORMALIZZAZIONE INTERNA STANDARDIZATION CODICE Code - - Symbol SIMBOLO 20114.EQP.ELE.STD 5 6 F.V. SET. '94 QUADRO BASSA TENSIONE - MOTOR CONTROL CENTER PARTENZA MOTORE B.T. CON INTERRUTTORE E CONTATTORE COMANDO DA COLONNINA E DA QUADRO STRUM. - COMANDO AUTOMATICO LVS758 Low voltage switchboard - Motor control center Low voltage motor feeder equipped with automatic circuit-breaker and contactor Operable from motor control station and instrumentation control panel - Automatic control SCHEMA LOGICO SEGNALAZIONI Indications logic diagram 1 -KM -F49 -KM & APERTO - Opened & Operated CHIUSO - INTERVENTO - Closed HW ICD-HW HR HG ICD-HG ICD-HB INTERVENTO - Operated -F50 Closed CHIUSO - -QM Closed CHIUSO - -KM APERTO - Opened -KM PARTE ESTRAIBILE IN POS. "INSERITO" - Tray in "IN" position Tray in "IN" position PARTE ESTRAIBILE IN POS. "INSERITO" - Tray in "TEST" position PARTE ESTRAIBILE IN POS. "PROVA" - NOTA : LE SEGNALAZIONI HW E ICD-HW DEVONO ESSERE PREVISTE SOLO QUANDO MANCA L'AMPEROMETRO Note : HW and ICD-HW indicators to be provided if ammeter is missing Documento di propriet aziendale. La Societ tuteler i propri diritti a termini di legge. Data Compilato Foglio - di Rev. Agip Sheet - of Compiled Date This document is Company Property. The Company lawfully reserves all rights. 0 NORMALIZZAZIONE INTERNA STANDARDIZATION CODICE Code - - Symbol SIMBOLO 20114.EQP.ELE.STD 6 6 F.V. SET. '94 QUADRO BASSA TENSIONE - MOTOR CONTROL CENTER PARTENZA MOTORE B.T. CON INTERRUTTORE E CONTATTORE COMANDO DA COLONNINA E DA QUADRO STRUM. - COMANDO AUTOMATICO LVS758 Low voltage switchboard - Motor control center Low voltage motor feeder equipped with automatic circuit-breaker and contactor Operable from motor control station and instrumentation control panel - Automatic control MORSETTIERA Terminal strip CONSENSO BLOCCO CONSENSO BLOCCO Push button station control COMANDI feeder Control ALIM. 1CK COLONNINA COMANDO 2 1 L1 N 5 3 4 1CM MISURE Measure 9 8 7 6 12 10 11 N L1 COMANDO station control Push button COLONNINA COMANDI feeder Control ALIM. 1CK 1 2 4 3 5 9 6 7 8 11 10 12 Consent lock and controls Indications SEGNALAZIONI E COMANDI 1CC 16 15 13 14 19 18 17 1CS 23 22 20 21 24 SEGNALAZIONI Consent lock and controls E COMANDI 1CC Indications 1CS 16 14 13 15 17 18 19 23 21 20 22 24