Sei sulla pagina 1di 6

ALUAFS, IS OAFS-ALU, SONOAFS-ALU, COMBIAFS

Pressure Loss Characteristics


TABLE-1 PRESSURE LOSS DIAGRAM
AIR VELOCITY (m/s)
30

26

24

22

20

18

16

14

12

10

10.000
9.000
8.000
7.000
6.000
5.000

s
m/

3.000

4.000

2.000
1.800
1.600
1.400

1.000
900
800
700

08
4

57
4

06

600

350

56

15
3 5
0
3

54

250

200

mm

300

R(
TE
ME
DIA

500
450
400

CT
DU

AIR VOLUME (m/h)

1.200

29
2

150

03

85

100
90
80
70

60
1

52

40
1

27

60
1

50

12

02
1 82

40
30
0.2

0.3

0.4

0.5

8 10

15

20

30

40 50

60

100

200

PRESSURE LOSS PER ONE METER OF FULLY EXTENDED DUCT ( Pa )

TABLE-2 BEND LOSS COEFFICIENTS

EQUIVALENT LENGHT
R

Z=Qx

R
90

2x90

Q=3 m

Q=4.5 m

D
300

Z = Equavalent lenght, m
Q = Bend loss coefficient
D = Duct diameter, mm

EXAMPLE

Temperature

45
Q=1.5 m

-20C

-0C

180
Q=7.5 m

+20C +40C +60C +80C +100C

Correction Fac. 1.158 1.073 1.000 0.936 0.880 0.830 0.785

(R/D=1)

Air Velocity
= 5 m/s
Duct Diameter = 203 mm
Pressure Loss = ?

90 Bend
= 1 piece
Duct Lenght = 4 m

Pressure Loss for 1 m Duct = 3 Pa(TABLE-1)


Bend Loss Coefficient
Equivalent Lenght
Pressure Loss

=3

(TABLE-2)
= 3 x 203 = 2.03 m
300
= (2.03 + 4)m x 3 Pa/m
= 18.09 Pa

POLYAFS, IS OAFS-POLY
Pressure Loss Characteristics
TABLE-1 PRESSURE LOSS DIAGRAM
AIR VELOCITY (m/s)
30

26

24

22

20

18

16

14

12

10

10.000
9.000
8.000
7.000
6.000
5.000
2m

4.000

/s

3.000

2.000
1.800
1.600
1.400

1.000
900
800
700

08

57

06

600

350

56

15
3 5
0
3

300

R(
TE
ME
DIA

500
450
400

CT
DU

AIR VOLUME (m/h)

1.200

mm

54

250

29

200

03

85

150

60

52

100
90
80
70

40

27

60

12
02
1 82

50
40
30

0.2

0.3

0.4

0.5

8 10

15

20

30

40 50

60

100

200

PRESSURE LOSS PER ONE METER OF FULLY EXTENDED DUCT ( Pa )

TABLE-2 BEND LOSS COEFFICIENTS

EQUIVALENT LENGHT
R

Z=Qx

R
90

2x90

Q=3 m

Q=4.5 m

D
300

Z = Equavalent lenght, m
Q = Bend loss coefficient
D = Duct diameter, mm

EXAMPLE

Temperature

45
Q=1.5 m

-20C

-0C

180
Q=7.5 m

+20C +40C +60C +80C +100C

Correction Fac. 1.158 1.073 1.000 0.936 0.880 0.830 0.785

(R/D=1)

Air Velocity
= 5 m/s
Duct Diameter = 203 mm
Pressure Loss = ?

90 Bend
= 1 piece
Duct Lenght = 4 m

Pressure Loss for 1 m Duct = 3.04 Pa (TABLE-1)


Bend Loss Coefficient
Equivalent Lenght
Pressure Loss

= 3 (TABLE-2)
= 3 x 203 = 2.03 m
300
= (2.03 + 4)m x 3.04 Pa/m
= 18.33 Pa

SEMIAFS, SEMIAFS-INOX
Pressure Loss Characteristics
TABLE-1 PRESSURE LOSS DIAGRAM
AIR VELOCITY (m/s)
30

26

24

22

20

18

16

14

12

10

10.000
9.000
8.000
7.000
6.000
5.000
2m

4.000

/s

3.000

2.000
1.800
1.600
1.400

1.000
900
800
700
600

350

00

50

R(
TE
ME
DIA

500
450
400

00

CT
DU

AIR VOLUME (m/h)

1.200

00

50

250

mm

300

200

00

150

80

60

1
100
90
80
70

50

40

27

60

10

50

00
1 80

40
30

0.2

0.3

0.4

0.5

8 10

15

20

30

40 50

60

100

200

PRESSURE LOSS PER ONE METER OF FULLY EXTENDED DUCT ( Pa )

TABLE-2 BEND LOSS COEFFICIENTS

EQUIVALENT LENGHT
R

Z=Qx

R
90

2x90

Q=3 m

Q=4.5 m

D
300

Z = Equavalent lenght, m
Q = Bend loss coefficient
D = Duct diameter, mm

EXAMPLE

Temperature

45
Q=1.5 m

-20C

-0C

180
Q=7.5 m

+20C +40C +60C +80C +100C

Correction Fac. 1.158 1.073 1.000 0.936 0.880 0.830 0.785

SEMIAFS (R/D=1)
SEMIAFS-INOX (R/D=5)

Air Velocity
= 5 m/s
Duct Diameter = 203 mm
Pressure Loss = ?

90 Bend
= 1 piece
Duct Lenght = 4 m

Pressure Loss for 1 m Duct = 3.12Pa (TABLE-1)


Bend Loss Coefficient
Equivalent Lenght
Pressure Loss

= 3 (TABLE-2)
= 3 x 200 = 2.0 m
300
= (2.0 + 4)m x 3.12 Pa/m
= 18.72 Pa

PVCAFS, IS OAFS-PVC
Pressure Loss Characteristics
TABLE-1 PRESSURE LOSS DIAGRAM
AIR VELOCITY (m/s)
30

26

24

22

20

18

16

14

12

10

10.000
9.000
8.000
7.000
6.000
5.000
2m

4.000

/s

3.000

1.200

1.000
900
800
700

600

350

57
06

56

15
3 5
0
3

mm

300

R(
TE
ME
DIA

500
450
400

08

CT
DU

AIR VOLUME (m/h)

2.000
1.800
1.600
1.400

54

250

29

200

03

150

85

60

1
100
90
80
70

52

40

27

60

12

50

02
1 82

40
30

0.2

0.3

0.4

0.5

8 10

15

20

30

40

50

60

100

200

PRESSURE LOSS PER ONE METER OF FULLY EXTENDED DUCT ( Pa )

TABLE-2 BEND LOSS COEFFICIENTS

EQUIVALENT LENGHT
R

Z=Qx

R
90

2x90

Q=3 m

Q=4.5 m

D
300

Z = Equavalent lenght, m
Q = Bend loss coefficient
D = Duct diameter, mm

EXAMPLE

Temperature

45
Q=1.5 m

-20C

-0C

180
Q=7.5 m

+20C +40C +60C +80C

Correction Fac. 1.158 1.073 1.000 0.936 0.880 0.830

(R/D=1)

Air Velocity
= 5 m/s
Duct Diameter = 203 mm
Pressure Loss = ?

90 Bend
= 1 piece
Duct Lenght = 4 m

Pressure Loss for 1 m Duct = 3.22Pa (TABLE-1)


Bend Loss Coefficient
Equivalent Lenght
Pressure Loss

=3

(TABLE-2)
= 3 x 203 = 2.03 m
300
= (2.03 + 4)m x 3.22 Pa/m
= 19.42 Pa

SONOAFS-ALU & SONOAFS-ALU F


Sound Attenuation Characteristics
TABLE - 1

L=1.000 mm

60

60
Lw1

Lw1

Lw3

Lw2
50

SOUND ATTENUATION (dB)

SOUND REDUCTION OF THE DUCT WALL (dB)

50

40

30

20

10

40

30

20

10

1/1 oct.

125

250
500
1.000
FREQUENCY (Hz)

2.000

4.000

18.4

15.2

11.1

16.3

10.8

9.3

1/1 oct.

125

250
500
1.000
FREQUENCY (Hz)

2.000

4.000

29.1

31.5

46.7

32.8

38.9

40.9

TABLE - 2

L=2.000 mm

60

60
Lw1

Lw1

Lw3

Lw2
50

SOUND ATTENUATION (dB)

SOUND REDUCTION OF THE DUCT WALL (dB)

50

40

30

40

30

20

20

10

10

125

250

500

1.000

2.000

4.000

125

1/1 oct.

21

17.9

13.3

11.9

250

500

1.000

2.000

4.000

49.2

44.6

FREQUENCY (Hz)

FREQUENCY (Hz)
13.8

18.6

1/1 oct.

27.7

43.4

39.1

Sound measurements of insulated air ducting according to ISO 7235:1991

42.8

SONOAFS-ALU S
Sound Attenuation Characteristics
TABLE - 1

L=1.000 mm

60

60
Lw1

Lw1

Lw3

Lw2
50

SOUND ATTENUATION (dB)

SOUND REDUCTION OF THE DUCT WALL (dB)

50

40

30

20

10

40

30

20

10

125

250

500

1.000

2.000

4.000

125

FREQUENCY (Hz)
1/1 oct.

20.2

21.8

16.7

14.8

250

500

1.000

15.6

18.7

1/1 oct.

11.7

20.6

45.4

46.2

TABLE - 2

28.1

Lw1
Lw3

Lw2
50

SOUND ATTENUATION (dB)

50

SOUND REDUCTION OF THE DUCT WALL (dB)

40.8

60
Lw1

40

30

40

30

20

20

10

10

125

250

500

1.000

2.000

4.000

125

FREQUENCY (Hz)
1/1 oct.

4.000

L=2.000 mm

60

2.000

FREQUENCY (Hz)

20.5

23.1

19.2

17.9

250

500

1.000

2.000

4.000

51.5

38.0

FREQUENCY (Hz)
17.3

21.3

1/1 oct.

8.5

19.6

49.9

Sound measurements of insulated air ducting according to ISO 7235:1991

50.8

Potrebbero piacerti anche