INDICE
1 AVVERTENZE ................................................................................................................................................... 2
ITALIANO
2 LAYOUT E COMPONENTI ................................................................................................................................. 2
2.1 DESCRIZIONE COMPONENTI ..................................................................................................................................... 3
2.2 DESCRIZIONE MORSETTIERA J13 ............................................................................................................................... 3
3 CARATTERISTICHE TECNICHE........................................................................................................................... 3
4 COLLEGAMENTI ELETTRICI .............................................................................................................................. 4
4.1 FOTOCELLULE A BUS-2EASY ....................................................................................................................................... 5
4.1.1 INDIRIZZAMENTO FOTOCELLULE BUS-2EASY .................................................................................................................5
4.1.2 MEMORIZZAZIONE ACCESSORI BUS-2EASY ..................................................................................................................5
4.2 FOTOCELLULE TRADIZIONALI ..................................................................................................................................... 6
4.3 COLLEGAMENTI INGRESSO SAFE ................................................................................................................. 7
5 PROGRAMMAZIONE ...................................................................................................................................... 8
5.1 PROGRAMMAZIONE 1° LIVELLO ............................................................................................................................... 8
5.2 PROGRAMMAZIONE 2° LIVELLO .............................................................................................................................. 10
6 MEMORIZZAZIONE CODIFICA RADIO .......................................................................................................... 12
6.1 MEMORIZZAZIONE DEI RADIOCOMANDI DS ........................................................................................................... 12
6.2 MEMORIZZAZIONE DEI RADIOCOMANDI SLH ........................................................................................................ 13
6.3 MEMORIZZAZIONE DEI RADIOCOMANDI LC/RC (SOLO PER ALCUNI MERCATI) ...................................................... 13
6.3.1 MEMORIZZAZIONE REMOTA RADIOCOMANDI LC/RC ................................................................................................13
6.4 PROCEDURA DI CANCELLAZIONE DEI RADIOCOMANDI ........................................................................................ 13
7 MESSA IN FUNZIONE .................................................................................................................................... 14
7.1 VERIFICA DEI LEDS .................................................................................................................................................... 14
7.2 FUNZIONAMENTO A BATTERIA ................................................................................................................... 14
7.3 POSIZIONAMENTO DEI FINECORSA ........................................................................................................................ 15
7.4 CONFIGURAZIONI MASTER/SLAVE ........................................................................................................................... 16
7.4.1 CABLAGGI MASTER/SLAVE.......................................................................................................................................... 16
7.4.2 PROCEDURA DI SETUP MASTER/SLAVE ........................................................................................................................ 16
7.5 SETUP ....................................................................................................................................................................... 17
8 PROVA DELL’AUTOMAZIONE ......................................................................................................................... 17
9 SEGNALAZIONE ALLARMI ED ERRORI ............................................................................................................ 17
9.1 ALLARMI .................................................................................................................................................................. 17
9.2 ERRORI ................................................................................................................................................................... 17
10 LOGICHE DI FUNZIONAMENTO .................................................................................................................. 18
DICHIARAZIONE CE DI CONFORMITÁ
Fabbricante: )$$&6S$
Indirizzo: 9LD&DODUL=ROD3UHGRVD%2/2*1$,7$/,$
Dichiara che: /·DSSDUHFFKLDWXUDHOHWWURQLFD(
qFRQIRUPHDLUHTXLVLWLHVVHQ]LDOLGLVLFXUH]]DGHOOHVHJXHQWLGLUHWWLYH&((
&('LUHWWLYD%DVVD7HQVLRQH
&('LUHWWLYD&RPSDWLELOLWj(OHWWURPDJQHWLFD
1RWDDJJLXQWLYD
4XHVWRSURGRWWRqVWDWRVRWWRSRVWRDWHVWLQXQDFRQILJXUD]LRQHWLSLFD
RPRJHQHDWXWWLSURGRWWLGLFRVWUX]LRQH)$$&6S$
%RORJQD
/·$PPLQLVWUDWRUH'HOHJDWR
$0DUFHOODQ
AVVERTENZE
$WWHQ]LRQHËLPSRUWDQWHSHUODVLFXUH]]DGHOOHSHUVRQHVHJXLUHDWWHQWDPHQWHWXWWDO·LVWUX]LRQH
8QDHUUDWDLQVWDOOD]LRQHRXQHUUDWRXVRGHOSURGRWWRSXzSRUWDUHDJUDYLGDQQLDOOHSHUVRQH
/HJJHUHDWWHQWDPHQWHOHLVWUX]LRQLSULPDGLLQL]LDUHO·LQVWDOOD]LRQHGHOSURGRWWRHFRQVHUYDUOHSHUULIHULPHQWLIXWXUL
,O VLPEROR HYLGHQ]LD OH QRWH LPSRUWDQWL SHU OD VLFXUH]]D GHOOH SHUVRQH H O·LQWHJULWj
GHOO·DXWRPD]LRQH
,OVLPEROR ULFKLDPDO·DWWHQ]LRQHVXOOHQRWHULJXDUGDQWLOHFDUDWWHULVWLFKHRGLOIXQ]LRQDPHQWRGHO
SURGRWWR
E721 1 532014 - Rev. D
E721
ITALIANO
1 AVVERTENZE
Prima di effettuare qualsiasi tipo di intervento sull’apparecchiatura elettronica (collegamenti,
manutenzione) togliere sempre l’alimentazione elettrica.
2 LAYOUT E COMPONENTI
/ SAFE
/ SAFE
SENSORE
FINECORSA
)LJ
ITALIANO
6: 38/6$17(352*5$00$=,21(´F” Potenza assorbita :
6: 38/6$17(352*5$00$=,21(´-” da rete stand-by
Carico max. $
6: 38/6$17(352*5$00$=,21(´+” per motore
6: 38/6$17(',´SETUP” Alimentazione 9
accessori
/HGV /('',&21752//267$72,1*5(66,
Corrente max 9 PD[P$
- &211(7725($/,0(17$=,21(35,0$5,$ accessori %86($6<PD[P$
- &211(7725(35,0$5,275$6)250$725( Temperatura &
ambiente
- &211(7725(6(&21'$5,275$6)250$725( Carico lampeg- 9 :
- &211(7725(%$77(5,((0(5*(1=$$&&(6625,2 giatore
Carico uscita 9 P$ (2)
- &211(7725(02725(
Fusibili di ) 7$9a
- &211(7725(86&,7$/$03(**,$725((24 V= - 15W) protezione
&211(7725(%/2&&202725((&217$7726%/2&&2 Logiche di 6HPLDXWRPDWLFD6HPLDXWRPDWLFD
-
02725( funzionamento ´SDVVRSDVVR´$XWRPDWLFD$XWRPDWLFD
´SDVVRSDVVR”$XWRPDWLFDFRQIXQ]LRQH
- &211(7725(86&,7$287
WLPHU$XWRPDWLFD6LFXUH]]H$XWRPDWLFD
- &211(7725(86%3(5&2//(*$0(1723& 6LFXUH]]H´SDVVRSDVVR´$XWRPDWLFDFRQ
LQYHUVLRQHLQSDXVD6HPLDXWRPDWLFD´E”
- &211(7725(&2//(*$0(172',6326,7,9,%86($6<
/RJLFDPLVWD´E&”8RPRSUHVHQWH
- &211(7725(,1*5(66,,10256(77,(5$ Tempo di lavoro 3URJUDPPDELOHGDDPLQ
&211(7725(02'8/25,&(9(17(5$',2 Tempo di pausa 3URJUDPPDELOHGDDPLQ
-
3(5201,'(& OPEN A / OPEN B
/&' ',63/$<',6(*1$/$=,21((352*5$00$=,21( Forza motore 3URJUDPPDELOHVXOLYHOOL
Velocità motore 3URJUDPPDELOHVXOLYHOOL
) )86,%,/(3527(=,21(
apertura-chiusura
2.2 DESCRIZIONE MORSETTIERA J13 Ingressi/Uscite in $OLPHQWDWRUH%DWWHULD0RWRUH0RGXOR
connettore ;)%DWWHULHVEORFFRHOHWWULFREORF
N° INGRESSO DESCRIZIONE
FRPRWRUH%ORFFR0RWRUH86%
1 23(1$ 'LVSRVLWLYRFRQFRQWDWWR
N.AFKH Ingressi/Uscite in %86($6<23(1$23(1%&/26(6$)(
SURYRFDO·DSHUWXUDWRWDOH morsettiera 67236$)(*1')RWRFHOOXOH$SHUWXUDH
GHOFDQFHOOR &KLXVXUD9 $OLPHQWD]LRQHGLUHWH
2-6 *1' 1HJDWLYRDOLPHQWD]LRQH /DPSHJJLDQWH6EORFFRHOHWWULFREORFFR
DFFHVVRUL PRWRUH287
3 23(1% 'LVSRVLWLYRFRQFRQWDWWR
'()$8/7 N.A.FKHSURYRFDO·DSHUWXUD
SDU]LDOHGHOFDQFHOOR
CLOSE 'LVSRVLWLYRFRQFRQWDWWR
N.A.FKHSURYRFDOD (1) Le tipologie di utilizzo degli ingressi 3 e
FKLXVXUDGHOFDQFHOOR 4 sono impostabili attraverso la configu-
6$)( 'LVSRVLWLYRFRQFRQWDWWR razione dei relativi parametri al 2° livello
N.C.FKHSURYRFD di programmazione (parametro Ob e SP).
O·LQYHUVLRQHLPPHGLDWDH Per l’esatta descrizione sul funzionamento
FRPSOHWDGHOFDQFHOOR dell’automazione in relazione alle logiche
4 6723 'LVSRVLWLYRFRQFRQWDWWR selezionate, fare riferimento alle tabelle
'()$8/7 N.C.FKHSURYRFDO·DUUHVWR che si trovano in fondo a questo manuale
GHOFDQFHOOR (Par. 10 - LOGICHE DI FUNZIONAMENTO).Per
6$)( 'LVSRVLWLYRFRQFRQWDWWR quanto riguarda i cablaggi da effettuare
N.C.FKHSURYRFD utilizzando questi ingressi configurati come
O·LQYHUVLRQHLPPHGLDWDH
FRPSOHWDGHOFDQFHOOR SAFE, fare riferimento agli schemi indicati
in Fig.13 e Fig. 14
5 )6:23 'LVSRVLWLYRFRQFRQWDWWR
N.C.FKHSURYRFD
O·LQYHUVLRQHGHOPRWR (2) Il carico dell’uscita deve ritenersi già
GXUDQWHO·DSHUWXUDGHO
FDQFHOOR incluso nella corrente max disponibile per
gli accessori
7 )6:&/ 'LVSRVLWLYRFRQFRQWDWWR
N.C. FKHSURYRFD
O·LQYHUVLRQHGHOPRWR
GXUDQWHODFKLXVXUDGHO
FDQFHOOR
8 9 3RVLWLYRDOLPHQWD]LRQH
DFFHVVRUL
/ SAFE
/ SAFE
3HULOFROOHJDPHQWRGHOOH
IRWRFHOOXOHHGHLGLVSRVL
WLYLGLVLFXUH]]DULIHULUVLDO
SDUDJUDIR
230 V ~
115 V ~
=
CONTATTO
SBLOCCO MOTORE
(Blocca il motore quan-
do si aziona la maniglia
= di sblocco motore)
)LJ
E721
E721 E721
E721
C720
C 72 C721
C 721
)LJ
$ )RWRFHOOXOHFRQLQWHUYHQWRLQ&+,8685$
% )RWRFHOOXOHFRQLQWHUYHQWRLQ$3(5785$
& )RWRFHOOXOHFRQLQWHUYHQWRLQ$3(5785$H&+,8685$
)LJ
ITALIANO
FKHGHYRQRSURWHJJHUH 'LS 'LS 'LS 'LS 5LI 7LSRORJLD
Sicurezze in chiusura: LQWHUYHQJRQR VROWDQWR GXUDQWH LO
2)) 2)) 2)) 2))
PRYLPHQWRGLFKLXVXUDGHOO·DXWRPD]LRQHTXLQGLVRQR
DGDWWHDSURWHJJHUHOD]RQDGLFKLXVXUDGDOULVFKLRGL 2)) 2)) 2)) 21
LPSDWWR 2)) 2)) 21 2))
Sicurezze in apertura: LQWHUYHQJRQRVROWDQWRGXUDQWHLO % $3(5785$
2)) 2)) 21 21 Max 6 coppie
PRYLPHQWRGLDSHUWXUDGHOO·DXWRPD]LRQHTXLQGLVRQR
DGDWWHDSURWHJJHUHOD]RQDGLDSHUWXUDGDOULVFKLRGL 2)) 21 21 2))
LPSDWWR
Sicurezze in apertura/chiusura: LQWHUYHQJRQRVLDGXUDQWH 2)) 21 21 21
LOPRYLPHQWRGLDSHUWXUDHFKLXVXUDGHOO·DXWRPD]LRQH 21 2)) 2)) 2))
TXLQGLVRQRDGDWWHDSURWHJJHUHWXWWDOD]RQDGLPR
21 2)) 2)) 21
YLPHQWD]LRQHGDOULVFKLRGLLPSDWWR
21 2)) 21 2))
4.1 FOTOCELLULE A BUS-2EASY &+,8685$
21 2)) 21 21 $ Max 7 coppie
4XHVWD VFKHGD q SURYYLVWD GL FLUFXLWR %86($6< FKH
FRQVHQWHGLFROOHJDUHIDFLOPHQWHXQHOHYDWRQXPHURGL 21 21 2)) 2))
GLVSRVLWLYL%86($6<DXVLOLDULDOODVLFXUH]]DDGHVILQRD 21 21 2)) 21
FRSSLHGLIRWRFHOOXOHRSSRUWXQDPHQWHSURJUDPPDWL
XWLOL]]DQGRVRODPHQWHGXHFDYLVHQ]DSRODULWj 21 21 21 2))
3ULPDGLFROOHJDUHOHIRWRFHOOXOHqRSSRUWXQRVFHJOLHUQH 2)) 21 2)) 2)) $3(5785$H
LOWLSRGLIXQ]LRQDPHQWR)LJLQEDVHDOOD]RQDGLPRYL & &+,8685$
2)) 21 2)) 21 Max 2 coppie
PHQWRFKHGHYRQRSURWHJJHUHHSRVL]LRQDUHLGLSVZLWFK
VLDVXOWUDVPHWWLWRUHHVLDVXOULFHYLWRUHYHGL)LJFRPH 21 21 21 21 ,038/6223(1
GD7DE
4.1.2 MEMORIZZAZIONE ACCESSORI BUS-2EASY
)LJ DL1 $OOLQHD ,QTXDOVLDVLPRPHQWRqSRVVLELOHDJJLXQJHUHIRWRFHOOXOH
PHQWR H DFFHVVRUL %86($6< DOO·LPSLDQWR VHPSOLFHPHQWH VH
DL2 6WDWR JXHQGRODVHJXHQWHSURFHGXUD
%86($6<$OL ,QVWDOODUHHSURJUDPPDUHJOLDFFHVVRULFRQO·LQGLUL]]R
RX TX PHQWD]LRQH GHVLGHUDWRYHGLSDU
DL2 DS1 'LS 7RJOLHUHDOLPHQWD]LRQHDOODVFKHGD
DL1
VZLWFKHVSHUOD &ROOHJDUHLGXHFDYLGHJOLJOLDFFHVVRUL%86($6<DOOD
PRUVHWWLHUDURVVD-SRODULWjLQGLIIHUHQWH
ON ON
DS1 DS1
1 2 3 4 1 2 3 4
SURJUDPPD
DL2 ]LRQH $OLPHQWDUHODVFKHGD
BUS BUS BUS BUS 3UHPHUHUDSLGDPHQWHXQDYROWDLOSXOVDQWH6(7836:
SHU HVHJXLUH O·LVFUL]LRQH GHJOL DFFHVVRUL 9HULILFDUH LO
RX - TX IXQ]LRQDPHQWRGHLGLVSRVLWLYLD%86($6<LQVWDOODWL
/DVFKHGDKDPHPRUL]]DWRJOLDFFHVVRUL%86($6<
6HJXLUHOHLQGLFD]LRQHGHOODWDEHOODVHJXHQWHSHUFRQWUROODUH
4.1.1 INDIRIZZAMENTO FOTOCELLULE BUS-2EASY LOEXRQRVWDWRGHOFROOHJDPHQWR%86($6<
È importante dare sia al trasmettitore che
La stessa procedura va eseguita su una
al ricevitore lo stesso indirizzo.
centrale MASTER anche per l’acquisizione
di una centrale SLAVE collegata al BUS-
Accertarsi che non vi siano due o più cop-
2EASY con collegamento POLARIZZATO.
pie di fotocellule con lo stesso indirizzo.
Tab. 2 - Descrizione led BUS-2EASY
Se non si utilizza alcun accessorio BUS- 1RUPDOHDWWLYLWjOHGDFFHVRDQFKHLQDV
2EASY, lasciare libero il connettore BUS- Acceso
VHQ]DGLIRWRFHOOXOH1HVVXQDIRWRFHOOXOD
2EASY (J12 - fig. 1). fisso
LVFULWWDLPSHJQDWD
Lampeg-
$OPHQRXQDIRWRFHOOXODLVFULWWDLPSHJQDWD
giante
RQRQDOOLQHDWD
lento
Spento
(flash ogni /LQHD%86($6<LQFRUWRFLUFXLWR
2,5 sec.)
/LQHD%86($6<GLVDWWLYDWDQRQIRUQLVFH
DOLPHQWD]LRQH
Spento
)XQ]LRQDPHQWRDEDWWHULD
&HQWUDOHSURJUDPPDWDFRPH6/$9(
E721 5 532014 - Rev. D
4.2 FOTOCELLULE TRADIZIONALI &ROOHJDPHQWRGLXQDFRSSLDGLIRWRFHOOXOHLQFKLXVXUD
HXQDLQDSHUWXUD
&ROOHJDPHQWRFRSSLDGLIRWRFHOOXOHLQFKLXVXUD
ITALIANO
FRQVLFXUH]]D)$,/6$)(attivata
Impostare nel secondo livello di programmazione
o1 = 01
OUT
Altre sicurezze
OUT
OUT
&ROOHJDPHQWRFRSSLDGLIRWRFHOOXOHLQFKLXVXUD )LJ
FRQVLFXUH]]D)$,/6$)(H6723disattivata
&ROOHJDPHQWRGLGXHFRSSLHGLIRWRFHOOXOHLQFKLXVXUD
Altre sicurezze
)LJ
&ROOHJDPHQWRXQDFRSSLDGLIRWRFHOOXOHLQDSHUWXUD
Altre sicurezze
)LJ )LJ
ITALIANO
)LJ
)LJ
Altre sicurezze
Altre sicurezze
OPEN A OPEN A
GND GND
OPEN B / CLOSE - OUT SAFE / OPEN B / CLOSE
- OUT SAFE / STOP STOP
FSW OP FSW OP
GND GND
FSW CL FSW CL
+24V +24V )LJ
Nel caso venga disattivata la sicurezza Fail Safe (parametro configurabile nel 2° livello di programmazio-
ne), il negativo da utilizzare per la gestione dell’ingresso SAFE dovrà essere il - (vedi Fig. 14).
Altre sicurezze
OPEN A
Altre sicurezze OPEN A
GND
OPEN B / CLOSE GND
SAFE / STOP - SAFE / OPEN B / CLOSE
- FSW OP STOP
GND FSW OP
FSW CL GND
+24V FSW CL
+24V )LJ
Nel caso non vengano utilizzati dispositivi con contatto N.C. (Altre sicurezze) l’ingresso SAFE divrà essere
ponticellato al -OUT con FAIL SAFE attivato o al GND con FAIL SAFE disattivato.
E721 7 532014 - Rev. D
5 PROGRAMMAZIONE La modifica dei parametri di program-
mazione diventa efficace appena viene
3HUSURJUDPPDUHLOIXQ]LRQDPHQWRGHOO·DXWRPD]LRQHqQH
eseguita, mentre la memorizzazione
FHVVDULRDFFHGHUHDOODPRGDOLWj´352*5$00$=,21(”
ITALIANO
ITALIANO
,OWHPSRGLSDXVDDIURQWHGLXQFRPDQGRGLDSHUWXUDPARZIALE+DHIIHWWRVRODPHQWHVHq
VWDWDVHOH]LRQDWDXQDORJLFDDXWRPDWLFD5HJRODELOHGDDVHFDSDVVLGLXQVHFRQGR
,QVHJXLWRODYLVXDOL]]D]LRQHFDPELDLQPLQXWLHGHFLQHGLVHFRQGLVHSDUDWLGDXQSXQWRHLO
WHPSRVLUHJRODDSDVVLGLVHFRQGLILQRDOYDORUHPDVVLPRGL 9.5 PLQXWL
(6VHLOGLVSOD\LQGLFD2.5 LOWHPSRGLSDXVDFRUULVSRQGHDPLQHVHF
Parametro non visualizzato in modalità SLAVE
FORZA MOTORE:
FO 5HJRODLOOLYHOORGLIRU]DGHOPRWRUH
50
01 IRU]DPLQLPD
50 IRU]DPDVVLPD
Variando il valore della forza è consigliabile eseguire un nuovo SETUP (vedi
par. 7.3)
VELOCITÀ APERTURA:
So 5HJRODVXOLYHOOLODYHORFLWjGLDSHUWXUDGHOPRWRUH
08
01 YHORFLWjPLQLPD
10 YHORFLWjPDVVLPD
Variando il valore della velocità è consigliabile eseguire un nuovo SETUP
(vedi par. 7.3)
VELOCITÀ CHIUSURA:
Sc 5HJRODVXOLYHOOLODYHORFLWjGLFKLXVXUDGHOPRWRUH
08
01 YHORFLWjPLQLPD
10 YHORFLWjPDVVLPD
Variando il valore della velocità è consigliabile eseguire un nuovo SETUP
(vedi par. 7.3)
RALLENTAMENTO IN APERTURA:
ro 5HJRODORVSD]LRGLUDOOHQWDPHQWRFRPHSHUFHQWXDOHGHOODFRUVDWRWDOHGHOFDQFHOOR5H
20
JRODELOHGD5 FRQYHORFLWj10 FRQYHORFLWjIUDH15 FRQYHORFLWj!D99
DSDVVLGL
5-10-15 UDOOHQWDPHQWRPLQLPR
99 UDOOHQWDPHQWRPDVVLPR
RALLENTAMENTO IN CHIUSURA:
rc 5HJRODORVSD]LRGLUDOOHQWDPHQWRFRPHSHUFHQWXDOHGHOODFRUVDWRWDOHGHOFDQFHOOR5H
20
JRODELOHGD5 FRQYHORFLWj10 FRQYHORFLWjIUDH15 FRQYHORFLWj!D99
DSDVVLGL
5-10-15 UDOOHQWDPHQWRPLQLPR
99 UDOOHQWDPHQWRPDVVLPR
VELOCITÀ IN RALLENTAMENTO:
Sr 5HJRODODYHORFLWjGHOFDQFHOORGXUDQWHLOUDOOHQWDPHQWR
0
0 YHORFLWj%$66$
1 YHORFLWj$/7$
STATO DELL’AUTOMAZIONE:
St 8VFLWDGDOODSURJUDPPD]LRQHPHPRUL]]D]LRQHGHLGDWLHULWRUQRDOODYLVXDOL]]D]LRQHGHOORVWDWRGHOO·DX
WRPD]LRQH
00 &+,862 07 )$,/6$)(LQFRUVR
01 $3(572 08 YHULILFDGLVSRVLWLYL%86($6<LQFRUVR
02 )HUPRSRL´$35(” 09 3UHODPSHJJLRSRL´$35(”
03 )HUPRSRL´&+,8'(” 10 3UHODPSHJJLRSRL´&+,8'(”
04 ,Q´3$86$” 11 $3(572LQ$SHUWXUD3DU]LDOH
05 ,QIDVHGLDSHUWXUD 12 ,Q3$86$$SHUWXUD3DU]LDOH
06 ,QIDVHGLFKLXVXUD
PROGRAMMAZIONE 2° LIVELLO
ITALIANO
(·SRVVLELOHUHJRODUHO·DPSLH]]DGHOO·DSHUWXUDSDU]LDOHGHOO·DQWDFRPHSHUFHQWXDOHGHOODFRUVD
WRWDOHGHOFDQFHOOR
5HJRODELOHGDDDSDVVLGL
00 QHVVXQDDSHUWXUDSDU]LDOH
01 DSHUWXUDSDU]LDOHPLQLPD
99 DSHUWXUDSDU]LDOHPDVVLPD
TEMPO LAVORO (time-out):
t (·RSSRUWXQRLPSRVWDUHXQYDORUHVXSHULRUHDOWHPSRQHFHVVDULRDOFDQFHOORSHUDSULUHH 2.0
FKLXGHUHFRPSOHWDPHQWH
5HJRODELOHGD 0 D 59 VHFDSDVVLGLVHFRQGR,QVHJXLWRODYLVXDOL]]D]LRQHFDPELDLQ
PLQXWLHGHFLQHGLVHFRQGLVHSDUDWLGDXQSXQWRHLOWHPSRVLUHJRODDSDVVLGLVHFRQGL
ILQRDOYDORUHPDVVLPRGL9.5 PLQXWL
(6VHLOGLVSOD\LQGLFD2.5 LOWHPSRGLSDXVDFRUULVSRQGHDPLQHVHF
In caso di impianto con configurazione MASTER/SLAVE sarà necessario impostare
un TEMPO LAVORO sulla centrale MASTER che tenga conto dei tempi di
movimentazione di entrambe le ante.
OUT 1:
o1 &RQVHQWHGLLPSRVWDUHO·XVFLWD287RSHQFROOHFWRU1$DWWLYDLQXQDGHOOHVHJXHQWLIXQ]LRQL 00
00 6HPSUHDWWLYDIRUQLVFHWHQVLRQH9 FRQDVVRUELPHQWRPDVVLPRGLP$
01 )$,/6$)(9HULILFDLOFRUUHWWRIXQ]LRQDPHQWRGHOOHIRWRFHOOXOHWUDGL]LRQDOLFROOHJDWH
02 /$03$'$63,$VSHQWDGDFKLXVRDFFHVDLQDSHUWXUDHDSHUWRSDXVDODPSHJJLDQWHLQFKLXVXUD
03 /8&(',&257(6,$YHGLIXQ]LRQHVXFFHVVLYD
04 $//$50(IXQ]LRQDPHQWRD%$77(5,$
05 FDQFHOOR$3(572RGLQ3$86$
06 FDQFHOOR&+,862
07 FDQFHOORLQ029,0(172
08 FDQFHOORLQ$3(5785$
09 FDQFHOORLQ&+,8685$
1 0 VLFXUH]]D$77,9$
1 1 XVFLWDWHPSRUL]]DWDDWWLYDELOHGDOVHFRQGRFDQDOHUDGLRYHGLIXQ]LRQHVXFFHVVLYD
1 2 XVFLWDDWWLYDELOHGDOVHFRQGRFDQDOHUDGLRIXQ]LRQHSDVVRSDVVR
TEMPORIZZAZIONE OUT 1 (visibile solo se al passo precedente è stata selezionata la voce
t1 03 o 11 ): 02
&RQVHQWHGLUHJRODUHODWHPSRUL]]D]LRQHGHOO·XVFLWD287QHOFDVRVLDVWDWDVHOH]LRQDWDXQD
IXQ]LRQHDWHPSRFRPHDGHV03 R 11 GD 1 D99 PLQXWLDSDVVLGLPLQXWR
OPEN B / CLOSE/SICUREZZA COSTA:
Ob ËSRVVLELOHVHOH]LRQDUHO·XVRGHOO·LQJUHVVR23(1%FRPHDSHUWXUDSDU]LDOHFRPDQGRGL&/26(
00
R6,&85(==$&267$
00 23(1%
01 &/26(
02 6,&85(==$&267$FRQWDWWR1&
Nel caso si selezioni una logica di funzionamento che prevede l’utilizzo del co-
mando di CLOSE (logica b, bC, C) questa funzione sarà preimpostata a 01 e
non sarà possibile modificarla.
STOP / SICUREZZA COSTA:
SP ËSRVVLELOHVHOH]LRQDUHO·XVRGHOO·LQJUHVVR6723FRPH6723R6,&85(==$&267$
00
00 6723
01 6,&85(==$&267$FRQWDWWR1&
INVERSIONE PARZIALE:
IP ËSRVVLELOHVHOH]LRQDUHODWLSRORJLDGLLQYHUVLRQHFRPSOHWDRSDU]LDOHDVHJXLWRGLXQRVWDFROR no
RDVHJXLWRGLLQWHUYHQWRGHOODFRVWDVHQVLELOH
Y $WWLYD]LRQHLQYHUVLRQHSDU]LDOH$VHJXLWRGLRVWDFRORRDWWLYD]LRQHFRVWDVHQVLELOH
O·DQWDLQYHUWHODPRYLPHQWD]LRQHSHUXQWHPSRGLFLUFD”SHUSRLIHUPDUVL
no 'LVDWWLYD]LRQHLQYHUVLRQHSDU]LDOH$VHJXLWRGLRVWDFRORRDWWLYD]LRQHFRVWDVHQVLELOHO·DQWD
LQYHUWHFRPSOHWDPHQWHODPRYLPHQWD]LRQHSRUWDQGRVLLQSRVL]LRQHGLDSHUWRRFKLXVR
BLOCCO MOTORE:
Lc ËSRVVLELOHVHOH]LRQDUHO·XWLOL]]RGHOEORFFRPRWRUHGXUDQWHLOIXQ]LRQDPHQWRDEDWWHULD Y
Y LOEORFFRPRWRUHFRQWLQXDDIXQ]LRQDUHUHJRODUPHQWHDQFKHGXUDQWHLOIXQ]LRQD
PHQWRDEDWWHULD
n o TXDQGRVLSDVVDDOIXQ]LRQDPHQWRDEDWWHULDLOEORFFRPRWRUHULPDQHVHPSUH
DSHUWR
E721 11 532014 - Rev. D
Display Funzione Default 1
RICHIESTA ASSISTENZA - CONTACICLI (abbinata alle due funzioni successive):
AS no
ITALIANO
Y DOUDJJLXQJLPHQWRGHOQXPHURGLFLFOLLPSRVWDELOHFRQOHIXQ]LRQLVXFFHVVLYH nc H
nd HIIHWWXDXQSUHODPSHJJLRGLVHFROWUHDTXHOORHYHQWXDOPHQWHJLjLPSRVWDWR
FRQODIXQ]LRQHPF SULPDGLRJQLPRYLPHQWD]LRQH
no OHIXQ]LRQLVXFFHVVLYHnc Hnd LQGLFDQRTXDQWLFLFOLKDHIIHWWXDWRO·LPSLDQWRILQRDG
XQPDVVLPRYLVXDOL]]DELOHGL99Ü990
6HLOQXPHURGLFLFOLHVHJXLWRqPDJJLRUHGLÜOHGXHIXQ]LRQLVXFFHV-
sive nc e nd visualizzeranno rispettivamente 99 e 99.
4XHVWDIXQ]LRQHSXzHVVHUHXWLOHSHULPSRVWDUHLQWHUYHQWLGLPDQXWHQ]LRQHSURJUDPPDWDR
SHUYHULILFDUHLFLFOLGLODYRURHVHJXLWL
PROGRAMMAZIONE CICLI (MIGLIAIA):
nc 6HAS Y LOGLVSOD\LQGLFDLOQXPHURGLPLJOLDLDGLFLFOLGRSRLOTXDOHVLULFKLHGHO·DVVLVWHQ]D
00
LPSRVWDELOHGD0 D99
6H AS no LOGLVSOD\LQGLFDLOQXPHURGLPLJOLDLDGLFLFOLHVHJXLWL,OYDORUHYLVXDOL]]DWRVL
DJJLRUQDFRQLOVXVVHJXLUVLGHLFLFOLLQWHUDJHQGRFRQLOYDORUHGLnd
Se AS = no premendo i tasti + e - per 5 sec. viene azzerato il contacicli.
PROGRAMMAZIONE CICLI (DECINE):
nd 6HAS Y LOGLVSOD\LQGLFDLOQXPHURGLGHFLQHGLFLFOLGRSRLOTXDOHVLULFKLHGHO·DVVLVWHQ]D
00
LPSRVWDELOHGD0 D99
6HAS no LOGLVSOD\LQGLFDLOQXPHURGLGHFLQHGLFLFOLHVHJXLWL,OYDORUHYLVXDOL]]DWRVLDJ
JLRUQDFRQLOVXVVHJXLUVLGHLFLFOLLQWHUDJHQGRFRQLOYDORUHGLnc
(VHPSLRVHO·LPSLDQWRKDHVHJXLWRÜYHUUjYLVXDOL]]DWR nc = 11 e
nd = 21
STATO DELL’AUTOMAZIONE:
St 8VFLWDGDOODSURJUDPPD]LRQHPHPRUL]]D]LRQHGHLGDWLHULWRUQRDOODYLVXDOL]]D]LRQHGHOORVWDWRGHOO·DXWRPD]LRQH
00 &+,862 07 )$,/6$)(LQFRUVR
01 $3(572 08 YHULILFDGLVSRVLWLYL%86($6<LQFRUVR
02 )HUPRSRL´$35(” 09 3UHODPSHJJLRSRL´$35(”
03 )HUPRSRL´&+,8'(” 10 3UHODPSHJJLRSRL´&+,8'(”
04 ,Q´3$86$” 11 $3(572LQ$SHUWXUD3DU]LDOH
05 ,QIDVHGLDSHUWXUD 12 ,Q3$86$$SHUWXUD3DU]LDOH
06 ,QIDVHGLFKLXVXUD
ITALIANO
divisi fra OPEN A ed OPEN B/CLOSE. divisi fra OPEN A ed OPEN B/CLOSE.
'RSRDYHUHVHJXLWRWXWWLLFROOHJDPHQWLHGDOLPHQWDWRODVFKHGDYHULILFDUHFRQODWDEHOODVRWWRVWDQWHORVWDWRGHLOHGV
LQUHOD]LRQHDOORVWDWRGHJOLLQJUHVVLLQILJODFRQGL]LRQHGLDXWRPD]LRQHFKLXVDDULSRVR
7DOL /(' LQGLFDQR OR VWDWR GHJOL LQJUHVVL GHOOD VFKHGD H VRQR GL LPSRUWDQ]D ULOHYDQWH DL ILQL GHOOD PRYLPHQWD]LRQH
GHOO·DXWRPDWLVPR
1RWDUHFKH LED ACCESO FRQWDWWRFKLXVR LED SPENTO FRQWDWWRDSHUWR
< (1) F
BUS 2EASY
< (2)
< OPEN A -
< GND
< OPEN B / CLOSE < SAFE
+
R
A
C
1
RADIO XF
R
2
IO
E
FC
FC
IO
O
< STOP / SAFE
W
R
D
O
R
A
P
R
< FSW OP
R
SETUP
< GND
< FSW CL
< +24
USB
BATTERY
RELEASE
Y
R
)
R
F
OUT
-L
E
S
S
E IN
TO
R M
K
K
K
T
-N
N
T EC
C
T
T RI
C
C
(P A
- +
A
LO
LA
LO
LO
M
R
P
M
B
<
<
<
<
<
<
<
<
<
)LJ
,OHG)&$H)&&UDSSUHVHQWDQRLFRQWDWWL1&'HOILQH Gli ingressi STOP (SAFE), FSW CL, FSW OP, OPEN
FRUVDLQWHJUDWRVXOODVFKHGDFKHVHLPSHJQDWLVLDSURQR B configurato come SAFE sono ingressi di
VSHJQHQGRGLFRQVHJXHQ]DLOOHGUHODWLYR sicurezza con contatto N.C. (Normalmente
Chiuso) e quindi i led corrispondenti devono
essere ACCESI in condizione di automatismo
)&$ a riposo, si spegneranno all’impegno del
$XWRPD]LRQH&+,86$
)&& )&&LPSHJQDWR dispositivo connesso.
Gli ingressi OPEN A, OPEN B/CLOSE sono
)&$ )&$LPSHJQDWR ingressi con contatto N.A. (Normalmente
$XWRPD]LRQH$3(57$ Aperto) e quindi i led corrispondenti devono
)&&
essere SPENTI in condizione di automatismo
a riposo, si accenderanno all’impegno del
Tab. 3 - Descrizione led POWER dispositivo connesso.
In caso di apparecchiatura programmata
Acceso fisso $OLPHQWD]LRQHGLUHWHSUHVHQWH come SLAVE i led corrispondenti alla morset-
tiera J13 dovranno essere spenti.
Lampeggiante $OLPHQWD]LRQHDEDWWHULD Led ERROR lampeggiante indica allarme
in corso (situazione non pregiudicante il
Spento 6FKHGDVSHQWD funzionamento del cancello)
Led ERROR acceso fisso indica errore in
corso (situazione che blocca il funziona-
7.2 FUNZIONAMENTO A BATTERIA mento fino alla eliminazione della causa
dell’errore)
ATTENZIONE
3HURWWLPL]]DUHLFRQVXPLHVDOYDJXDUGDUQHODFDULFDGXUDQWHLOIXQ]LRQDPHQWRDEDWWHULDDGDXWRPD]LRQHIHUPDH
VLVWHPDLQVWDQGE\LOGLVSOD\/&'LOOHG%86HDV\HLOHG)&&H)&$ULVXOWDQRVSHQWLPHQWUHLOOHG32:(5ODPSHJJLD
,QTXHVWDIDVHqFRPXQTXHSRVVLELOHYLVXDOL]]DUHORVWDWRGHOO·DXWRPD]LRQH3HUIDUORqVXIILFLHQWHSUHPHUHEUHYHPHQWH
LOWDVWR+SUHVHQWHVXOODVFKHGD6XFFHVVLYDPHQWHDTXHVWDEUHYHSUHVVLRQHLOGLVSOD\/&'PRVWUDSHUFLUFDVHFRQGL
ORVWDWRGHOO·DXWRPD]LRQHSHUSRLVSHJQHUVLQXRYDPHQWH'XUDQWHXQDQRUPDOHPRYLPHQWD]LRQHLQYHFHWXWWLLOHG
GLGLDJQRVWLFDHOHVHJQDOD]LRQLGLVWDWRGHOGLVSOD\ULWRUQDQRFRHUHQWLFRQORVWDWRGHOO·DXWRPD]LRQHYHGL)LJ
ITALIANO
sia installata e collegata correttamente con tutti gli accessori di comando e sicurezza .
/·RSHUDWRUHqGRWDWRGLXQVHQVRUHPDJQHWLFRGLILQHFRUVDLQWHJUDWRGLUHWWDPHQWHVXOODVFKHGDHOHWWURQLFDGLFRPDQGR
/·DUUHVWRGHOFDQFHOORLQDSHUWXUDRLQFKLXVXUDDYYLHQHQHOPRPHQWRLQFXLLOPDJQHWHSRODUL]]DWRILVVDWRQHOODSDUWH
VXSHULRUHGHOODFUHPDJOLHUDDWWLYDLOVHQVRUH
9HULILFDUHFKHO·RSHUDWRUHVLDVWDWRSUHGLVSRVWRSHULOIXQ]LRQDPHQWRPDQXDOHFRPHGD
LVWUX]LRQLGHOO·RSHUDWRUH
3RUWDUHPDQXDOPHQWHLOFDQFHOORLQSRVL]LRQHG·aperturaODVFLDQGRPPGDOO·DUUHVWR
PHFFDQLFRGLILQHFRUVDYHGL)LJ
)DUVFRUUHUHVXOODFUHPDJOLHUDLOPDJQHWHFROTONDOQHOODGLUH]LRQHGHOPRWRUH$SSHQD
A
C
R O1
2
FC
FC
IO
LOOHGUHODWLYRDOILQHFRUVD)&$SUHVHQWHVXOODVFKHGDVLVSHJQHILVVDUORFRQOHDSSRVLWH
I
D
R
A
A
YLWL
E
R
3RUWDUHPDQXDOPHQWHLOFDQFHOORLQSRVL]LRQHGLchiusuraODVFLDQGRPPGDOO·DUUHVWR
PHFFDQLFRGLILQHFRUVD
)DU VFRUUHUH VXOOD FUHPDJOLHUD LO PDJQHWH FRO QUADRATO QHOOD GLUH]LRQH GHO PRWRUH
$SSHQDLOOHGUHODWLYRDOILQHFRUVD)&&SUHVHQWHVXOODVFKHGDVLVSHJQHILVVDUORFRQOH
DSSRVLWHYLWL
A
C
R O1
2
FC
FC
IO
&RQWUROODUHFKHDILQHPDQRYUDVLDLQDSHUWXUDFKHLQFKLXVXUDLOOHGGHOULVSHWWLYRILQHFRUVD
I
D
R
A
E
VLVSHQJDFRUUHWWDPHQWHHQHOFDVRDSSRUWDUHOHRSSRUWXQHPRGLILFKHDOODSRVL]LRQHGHL
R
PDJQHWLGLILQHFRUVD
Per evitare danneggiamenti dell’operatore e/o interruzioni del funzionamento
dell’automazione è necessario lasciare circa 40 mm dagli arresti meccanici
di finecorsa.
)LJ
MASTER/SLAVE
)LJ
SHUO·DSHUWXUDHODFKLXVXUDGHOYDUFRFROOHJDUHHFRQILJXUDUHGXHDSSDUHFFKLDWXUH(LQPRGDOLWj0DVWHU6ODYH
/·DSSDUHFFKLDWXUD0$67(5SDUDPHWURC t GHOSULPROLYHOORGLSURJUDPPD]LRQHFRQILJXUDWRFRPHM A GRYUjDYHUH
WXWWLLFROOHJDPHQWLQHFHVVDULDOFRUUHWWRIXQ]LRQDPHQWRGHOO·LPSLDQWRIRWRFHOOXOHVLFXUH]]HUDGLRLPSXOVLGLDSHUWXUD
ODPSHJJLDQWHPHQWUHO·DSSDUHFFKLDWXUD6/$9(SDUDPHWURC t GHOSULPROLYHOORGLSURJUDPPD]LRQHFRQILJXUDWRFRPH
S L QRQGRYUjDYHUHQHVVXQWLSRGLFDEODJJLRQHOODPRUVHWWLHUD-GDWRFKHYHQJRQRLJQRUDWLFRPSOHWDPHQWH
JOLLQJUHVVLSUHVHQWL/HGXHDSSDUHFFKLDWXUHFRPXQLFKHUDQQRWUDGLORURDWWUDYHUVRLO%86($6<WUDPLWHXQFDEODJJLR
DGXHSROLPOLARIZZATOVXOODPRUVHWWLHUD-
/·DSSDUHFFKLDWXUD0$67(5FRQWUROOHUjFRPSOHWDPHQWHO·DSSDUHFFKLDWXUD6/$9(WUDPLWHLO%86($6<HJHVWLUjWXWWHOH
PRYLPHQWD]LRQLHLWHPSLGLHQWUDPEHOHDQWH
Evitare qualsiasi tipo di collegamento e cablaggio sulla morsettiera J13 della centrale SLAVE
Il collegamento BUS tra le due schede dovrà essere POLARIZZATO rispettando la sequenza dei
poli della morsettiera J12 (POLO (1) - POLO (2)) - (vedi Fig. 19).
Configurando una centrale come SLAVE vengono forzati i valori di alcuni parametri di program-
mazione non più visualizzati nel menù (LO-PA-Pb-Ph-Op). RIportando la scheda in modalità
MASTER questi valori, forzati precedentemente, vengono mantenuti all’interno della programma-
zione.
7.4.1 CABLAGGI MASTER/SLAVE
(1) (1)
BUS 2 EASY BUS 2 EASY
(2) (2)
1RQHIIHWWXDUHDOFXQ
FROOHJDPHQWRD
TXHVWDPRUVHWWLHUD
La richiesta di SETUP tramite il lampeggio della sigla S0 sul display può presentarsi sia sulla cen-
trale MASTER che sulla centrale SLAVE. Nel secondo caso sulla centrale MASTER comparirà un
errore 91 . In ogni caso l’avvio di una procedura di SETUP potrà essere effettuato solamente dalla
centrale MASTER.
3HUHVHJXLUHLO6(783LQXQLPSLDQWR0$67(56/$9(VHJXLUHLSDVVDJJLVHJXHQWL
In caso di errore o non completamento della procedura di SETUP sopra descritta sarà necessario
ripeterla completamente partendo dal punto n.1.
ITALIANO
stato eseguito un SETUP, o se la scheda lo
richiede, sul display lampeggia la sigla FKHKDQQREORFFDWRLOIXQ]LRQDPHQWRGHOFDQFHOORVXO
S0 assieme al led SETUP ad indicare che GLVSOD\qSRVVLELOHYHGHUHLOQXPHURUHODWLYRDOODFRQGL
è necessario eseguire il SETUP. ]LRQHLQHVVHUH
Le segnalazioni di ALLARME o ERRORE spa-
Per il buon esito della procedura di SETUP
riranno al ciclo successivo solo se verrà
verificare accuratamente la corretta pola-
rimossa la causa scatenante.
rità dei finecorsa magnetici come descritto
il paragrafo precedente. 9.1 ALLARMI
3HUHVHJXLUHLO6(783VHJXLUHLSDVVDJJLVHJXHQWL Quando si verifica un ALLARME il led ERROR
inizia a lampeggiare e premendo contem-
1. Portare il cancello a metà della corsa (molto im-
poraneamente i tasti + e - sul display verrà
portante per la riuscita del SETUP) e verificare che visualizzato il numero relativo all’anomalia
entrambi i led FCA e FCC siano accesi. In caso con- in corso.
trario la scheda segnalerà errore 12 (vedi tab. 5)
,Q 7DE VRQR LQGLFDWL WXWWL JOL DOODUPL YLVXDOL]]DELOL D GL
7HQHUSUHPXWRLOSXOVDQWH6(7836:ILQFKpLOFDQFHOOR
VSOD\
LQL]LDLOPRYLPHQWRUDOOHQWDWRIHUPDQGRVLDOUDJJLXQ
JLPHQWR GHO ILQHFRUVD 6H LO ILQHFRUVD UDJJLXQWR q Tab. 4 - Allarmi
TXHOORGLFKLXVXUDFROQUADRATOO·DSSDUHFFKLDWXUD 22 &RUUHQWH02725(OLPLWDWD
PHPRUL]]HUj TXHO SXQWR FRPH DUUHVWR LQ chiusura
YLFHYHUVD VH LO ILQHFRUVD q TXHOOR GL DSHUWXUD FRQ 24 8VFLWD/$03LQFRUWRFLUFXLWR
TONDOO·DSSDUHFFKLDWXUDPHPRUL]]HUjTXHOSXQWR 27 5LOHYD]LRQHRVWDFRORYLVLELOHSHUVHF
FRPHDUUHVWRLQapertura,QTXHVWDIDVHVXOGLVSOD\ 0HPRULDFRGLFLUDGLR;)PRGXOHSLHQDYLVL
ODPSHJJLDS 1
30 ELOHSHUVHF
,O FDQFHOOR LQL]LD DXWRPDWLFDPHQWH LO PRYLPHQWR 40 5LFKLHVWD$VVLVWHQ]D
UDOOHQWDWRQHOODGLUH]LRQHRSSRVWDIHUPDQGRVLDOUDJ
JLXQJLPHQWRGHOILQHFRUVD6HLOILQHFRUVDUDJJLXQWR
46 5LSULVWLQRIRU]DWRSURJUDPPD]LRQHGHIDXOW
EORFFDHDOGLVLPSHJQR
IN APERTURA EORFFDLOIXQ]LRQDPHQWR EORFFDLOIXQ]LRQDPHQWR ULFKLXGHLOFDQFHOOR EORFFDLOIXQ]LRQDPHQWR YHGLSURJOLY QHVVXQHIIHWWR DSUH23(1EORFFD
PHPRUL]]D&/26(
EORFFDHDOGLVLPSHJQR
IN APERTURA EORFFDLOIXQ]LRQDPHQWR EORFFDLOIXQ]LRQDPHQWR ULFKLXGHLOFDQFHOOR EORFFDLOIXQ]LRQDPHQWR YHGLSURJOLY QHVVXQHIIHWWR DSUH23(1EORFFD
PHPRUL]]D&/26(
FRQWLQXDDGDSULUHH EORFFDHDOGLVLPSHJQR
IN APERTURA QHVVXQHIIHWWR QHVVXQHIIHWWR ULFKLXGHLOFDQFHOOR EORFFDLOIXQ]LRQDPHQWR YHGLSURJOLY
ULFKLXGHVXELWR DSUH
PHPRUL]]D&/26(
ITALIANO
CHIUSO DSUHHULFKLXGHGRSRLO PHQWHHFKL XGHGRSRLO QHVVXQHIIHWWR QHVVXQHIIHWWR QHVVXQHIIHWWR QHVVXQHIIHWWR QHVVXQHIIHWWR
WHPSRSDXVD WHPSRSDXVD% 23(1LQLELWR 23(1LQLELWR 23(1LQLELWR
EORFFDHDOGLVLPSHJQR
IN APERTURA EORFFDLOIXQ]LRQDPHQWR EORFFDLOIXQ]LRQDPHQWR ULFKLXGHLOFDQFHOOR EORFFDLOIXQ]LRQDPHQWR YHGLSURJOLY QHVVXQHIIHWWR DSUH23(1EORFFD
PHPRUL]]D&/26(
IN CHIUSURA ULDSUHLOFDQFHOOR ULDSUHLOFDQFHOOR QHVVXQHIIHWWR EORFFDLOIXQ]LRQDPHQWR QHVVXQHIIHWWR LQYHUWHLQDSHUWXUDYHGL EORDSUH23(1EO
FFDHDOGLVLPSHJQR
RFFD
SURJOLY PHPRUL]]D&/26(
FRQWLQXDDGDSULUHH EORFFDHDOGLVLPSHJQR
IN APERTURA LQYHUWHLQFKLXVXUD LQYHUWHLQFKLXVXUD ULFKLXGHLOFDQFHOOR EORFFDLOIXQ]LRQDPHQWR YHGLSURJOLY ULFKLXGHVXELWR DSUH
PHPRUL]]D&/26(
FRQWLQXDDGDSULUHH EORFFDHDOGLVLPSHJQRDSUHH
IN APERTURA EORFFDLOIXQ]LRQDPHQWR EORFFDLOIXQ]LRQDPHQWR ULFKLXGHLOFDQFHOOR EORFFDLOIXQ]LRQDPHQWR YHGLSURJOLY ULFKLXGHVXELWR
DOWHUPLQHFKLXGHVXELWR23(1
EORFFDPHPRUL]]D&/26(
'XUDQWHLOFLFORGLDSHUWXUDSDU]LDOHXQLPSXOVRGL23(1$SURYRFDO·DSHUWXUDWRWDOH
E721 19 532014 - Rev. D
LOGICA “SA” ,038/6,
STATO AUTOMAZIONE OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
$SUHLOFDQFHOORSDU]LDO
ITALIANO
EORFFDHDOGLVLPSHJQR
IN APERTURA QHVVXQHIIHWWR QHVVXQHIIHWWR ULFKLXGHLOFDQFHOOR EORFFDLOIXQ]LRQDPHQWR YHGLSURJOLY QHVVXQHIIHWWR DSUH
PHPRUL]]D&/26(
EORFFDHDOGLVLPSHJQR
IN APERTURA QHVVXQHIIHWWR / FKLXGHLOFDQFHOOR EORFFDLOIXQ]LRQDPHQWR YHGLSURJOLY QHVVXQHIIHWWR DSUHPHPRUL]]D
23(1&/26(
EORFFDHDOGLVLPSHJQR
IN APERTURA QHVVXQHIIHWWR / FKLXGHLOFDQFHOOR EORFFDLOIXQ]LRQDPHQWR YHGLSURJOLY QHVVXQHIIHWWR DSUHPHPRUL]]D
23(1&/26(
ENGLISH
5 PROGRAMMING ............................................................................................................................................ 8
5.1 1st LEVEL PROGRAMMING ........................................................................................................................................ 8
5.2 2nd LEVEL PROGRAMMING ...................................................................................................................................... 10
6 STORING RADIO CODE ................................................................................................................................ 12
6.1 STORING DS RADIOCONTROLS ............................................................................................................................... 12
6.2 STORING SLH RADIOCONTROLS ............................................................................................................................. 13
6.3 STORING LC/RC RADIOCONTROLS (ONLY FOR SOME MARKETS) ............................................................................ 13
6.3.1 STORING LC/RC RADIOCONTROLS REMOTELY ...........................................................................................................13
6.4 RADIOCONTROLS DELETION PROCEDURE .............................................................................................................. 13
7 OPERATIONAL START-UP ............................................................................................................................... 14
7.1 CHECKING THE LEDS ................................................................................................................................................ 14
7.2 BATTERY OPERATION ............................................................................................................................... 14
7.3 POSITIONING LIMIT SWITCHES ....................................................................................................................................
7.4 MASTER / SLAVE CONFIGURATIONS ......................................................................................................................... 16
7.4.1 MASTER / SLAVE WIRING ............................................................................................................................................ 16
7.4.2 MASTER/SLAVE SETUP PROCEDURE ............................................................................................................................. 16
7.5 SETUP ....................................................................................................................................................................... 17
8 TESTING THE AUTOMATED SYSTEM ........................................................................................................... 17
9 ALARM AND ERROR SIGNALS .................................................................................................................. 17
9.1 ALARMS ................................................................................................................................................................... 17
9.2 ERRORS .................................................................................................................................................................. 17
10 FUNCTION LOGICS .................................................................................................................................... 18
CE DECLARATION OF CONFORMITY
Manufacturer: )$$&6S$
Address: 9LD&DODUL=ROD3UHGRVD%2/2*1$,7$/<
Declares that: &RQWUROERDUG(
FRQIRUPVWRWKHHVVHQWLDOVDIHW\UHTXLUHPHQWVRIWKHIROORZLQJ((&GLUHFWLYHV
(&/RZ9ROWDJH'LUHFWLYH
(&(OHFWURPDJQHWLF&RPSDWLELOLW\'LUHFWLYH
$GGLWLRQDOQRWH
7KLVSURGXFWKDVXQGHUJRQHWHVWLQJLQDW\SLFDO
VWDQGDUGFRQILJXUDWLRQDOOSURGXFWVEXLOWE\)$$&6S$
%RORJQD
7KH0DQDJLQJ'LUHFWRU
$0DUFHOODQ
WARNINGS
$WWHQWLRQ7RHQVXUHWKHVDIHW\RISHRSOHLWLVLPSRUWDQWWKDW\RXUHDGDOOWKHIROORZLQJLQVWUXFWLRQV
,QFRUUHFWLQVWDOODWLRQRULQFRUUHFWXVHRIWKHSURGXFWFRXOGFDXVHVHULRXVKDUPWRSHRSOH
&DUHIXOO\UHDGWKHLQVWUXFWLRQVEHIRUHEHJLQQLQJWRLQVWDOOWKHSURGXFWDQGNHHSIRUIXWXUHUHIHUHQFH
7KHV\PERO KLJKOLJKWVQRWHVWKDWDUHLPSRUWDQWIRUSHUVRQDOVDIHW\DQGWKHSURWHFWLRQRIWKHDXWRPDWHG
V\VWHP
7KHV\PERO FDOOV\RXUDWWHQWLRQWRQRWHVRQSURGXFWVSHFLILFDWLRQVRURSHUDWLRQ
Install, upstream of the system, a differential thermal breaker with adequate tripping threshold.
/ SAFE
/ SAFE
SENSOR
LIMIT SWITCH
)LJ
ENGLISH
- (0(5*(1&<%$77(5<&211(&725$&&(6625< Output load 9 P$ (2)
- 02725&211(&725 Protection ) 7$9a
fuses
- )/$6+,1*/$03&211(&725(24 V= - 15W) Function 6HPLDXWRPDWLF6HPLDXWRPDWLF“VWHS“
02725/2&.$1'027255(/($6( logics $XWRPDWLF$XWRPDWLF“VWHS”$XWR
- PDWLFZLWKWLPHUIXQFWLRQ$XWRPDWLF
&217$&7&211(&725
6DIHW\GHYLFHV$XWRPDWLF6DIHW\GHYLFHV
- 287287387&211(&725 “VWHS“$XWRPDWLFZLWKUHYHUVHRQSDXVH
- 86%&211(&725)253&&211(&7,21 6HPLDXWRPDWLF“E”0L[HGORJLF“E&”
'HDGPDQ
- %86($6<'(9,&(&211(&7,21&211(&725
Work time 3URJUDPPDEOHIURPWRPLQ
- ,1387&211(&725,1&211(&725%/2&. Pause time 3URJUDPPDEOHIURPWRPLQ
- 5$',25(&(,9(502'8/(&211(&725)25201,'(& OPEN A / OPEN B
Motor power $GMXVWDEOHRYHUOHYHOV
/&' 6,*1$//,1*$1'352*5$00,1*',63/$<
Opening-closing $GMXVWDEOHRYHUOHYHOV
) 3527(&7,21)86( motor speed
Connector Inputs/ 3RZHUVXSSO\%DWWHU\0RWRU0RGXOH
2.2 DESCRIPTION OF TERMINAL BLOCK J13 Outputs ;)0RWRUORFNHOHFWULFUHOHDVHEDW
WHULHV0RWRU/RFN86%
INPUT No DESCRIPTION
Inputs/Outputs in %86($6<23(1$23(1%&/26(6$)(
1 23(1$ 'HYLFHZLWKN.OFRQWDFW terminal block 67236$)(*1'2SHQLQJDQGFORVLQJ
WKDWFDXVHVWRWDORSHQLQJ SKRWRFHOOV9 0DLQVSRZHUVXSSO\
RIWKHJDWH )ODVKHU(OHFWULFUHOHDVHPRWRUORFN287
2-6 *1' $FFHVVRU\SRZHU Programming VWDQGQGOHYHOZLWKNH\V)DQG
VXSSO\QHJDWLYH GLVSOD\
3 23(1% 'HYLFHZLWKN.O.FRQWDFW
'()$8/7 WKDWFDXVHVSDUWLDORSHQLQJ (1) The uses of inputs 3 and 4 can be set by
RIWKHJDWH configuring the corresponding parameters
CLOSE 'HYLFHZLWKN.O.FRQWDFW at programming level 2 (parameters Ob
WKDWFORVHVWKHJDWH and SP). For the exact description on how
6$)( 'HYLFHZLWK N.C.FRQWDFW to operate the automated system with the
WKDWFDXVHVWKHLPPHGLDWH chosen logics, please refer to the tables
DQGFRPSOHWHUHYHUVDORI featured at the end of this manual (Par.
WKHJDWH 10 - OPERATION LOGICS. As for the wiring
4 6723 'HYLFHZLWKN.CFRQWDFW required using these SAFE configured
'()$8/7 WKDWKDOWVWKHJDWH inputs, please refer to the diagrams shown
in Fig.13 and Fig. 14
6$)( 'HYLFHZLWK N.C.FRQWDFW
WKDWFDXVHVWKHLPPHGLDWH
DQGFRPSOHWHUHYHUVDORI (2) The output load must be considered
WKHJDWH as already included in the max. current
available for the accessories
5 )6:23 'HYLFHZLWKN.CFRQWDFW
WKDWUHYHUVHVWKHPRWLRQ
GXULQJJDWHRSHQLQJ
7 )6:&/ 'HYLFHZLWKN.CFRQWDFW
WKDWUHYHUVHVWKHPRWLRQ
GXULQJJDWHFORVLQJ
8 9 $FFHVVRU\SRZHUVXSSO\
SRVLWLYH
/ SAFE
/ SAFE
ENGLISH
7RFRQQHFWWKHSKRWRFHOOV
DQGVDIHW\GHYLFHVFRQ
VXOWSDUDJUDSK
230 V ~
115 V ~
=
MOTOR RELEASE
CONTACT
(Locks the motor when
the motor release han-
= dle is operated)
)LJ
E721
E721 E721
E721
C720
C 72 C721
C 721
)LJ
$ 3KRWRFHOOVWKDWRSHUDWHGXULQJ&/26,1*
% 3KRWRFHOOVWKDWRSHUDWHGXULQJ23(1,1*
& 3KRWRFHOOVWKDWRSHUDWHGXULQJ23(1,1*DQG&/26,1*
)LJ
ENGLISH
WKHHQWLUHPRYHPHQWDUHDIURPWKHULVNRILPSDFW 21 2)) 2)) 21
21 2)) 21 2))
4.1 BUS-2EASY PHOTOCELLS
21 2)) 21 21 $ &/26,1*
7KLVERDUGLVHTXLSSHGZLWKD%86($6<FLUFXLWWKDWFDQ Max. 7 pairs
EHXVHGWRHDVLO\FRQQHFWDKLJKQXPEHURIDX[LOLDU\%86 21 21 2)) 2))
($6<GHYLFHVWRWKHVDIHW\GHYLFHHJXSWRSDLUVRI
SKRWRFHOOV DSSURSULDWHO\ SURJUDPPHG XVLQJ RQO\ WZR 21 21 2)) 21
FDEOHVZLWKRXWSRODULW\ 21 21 21 2))
%HIRUHFRQQHFWLQJWKHSKRWRFHOOVLWLVDGYLVDEOHWRVHOHFW
2)) 21 2)) 2)) 23(1,1*DQG
WKHW\SHRIRSHUDWLRQ)LJRQWKHEDVLVRIWKHDUHDRI & &/26,1*
PRYHPHQWWKHFHOOVPXVWSURWHFWDQGWRSRVLWLRQWKHGLS 2)) 21 2)) 21 Max. 2 pairs
VZLWFKHVRQERWKWKHWUDQVPLWWHUDQGUHFHLYHUVHH)LJ 21 21 21 21 23(138/6(
DVLQ7DE
4.1.2 STORING BUS-2EASY ACCESSORIES
DL1 $OLJQ $W DQ\ WLPH LW LV SRVVLEOH WR DGG %86($6< SKRWRFHOOV
)LJ PHQW DQG DFFHVVRULHV WR WKH V\VWHP VLPSO\ E\ IROORZLQJ WKH
DL2 %86 SURFHGXUHEHORZ
($ 6<3RZHU ,QVWDOO DQG SURJUDPPH WKH DFFHVVRULHV ZLWK WKH
VXSSO\VWDWXV UHTXLUHGDGGUHVVVHHSDU
RX TX DS1 'LS &XWRIISRZHUWRWKHERDUG
DL2 V Z L W F K H V I R U &RQQHFWERWKFDEOHVRIWKH%86($6<DFFHVVRULHVWR
DL1
WKHUHGWHUPLQDOEORFN-SRODULW\LUUHOHYDQW
SURJUDPPLQJ
3RZHUWKHERDUG
ON ON
DS1 DS1
1 2 3 4 1 2 3 4
DL2
4XLFNO\ SUHVV WKH 6(783 SXVKEXWWRQ 6: RQFH WR
BUS BUS BUS BUS UHJLVWHUWKHDFFHVVRULHV&KHFNWKHRSHUDWLRQRIWKH
LQVWDOOHG%86($6<GHYLFHV
RX - TX
7KHERDUGKDVVWRUHGWKH%86($6<DFFHVVRULHV
OUT
ENGLISH
Other safety
devices
OUT
OUT
)LJ
&RQQHFWLRQRISDLURIFORVLQJSKRWRFHOOV
ZLWK)$,/6$)(DQG6723VDIHW\GHYLFHdeactivated
&RQQHFWLRQRIWZRSDLUVRIFORVLQJSKRWRFHOOV
Other safety
devices
)LJ
&RQQHFWLRQRIDSDLURIRSHQLQJSKRWRFHOOV
Other safety
devices
)LJ )LJ
E721 6 532014 - Rev. D
&RQQHFWLRQRIDSDLURIFORVLQJSKRWRFHOOVDSDLURIRSHQ &RQQHFWLRQRIQRVDIHW\DQGVWRSGHYLFH
LQJSKRWRFHOOVDQGDSDLURIRSHQLQJFORVLQJSKRWRFHOOV
)LJ
ENGLISH
)LJ
In case N.C. contact devices are not used (other safety devices) the SAFE input must be jumpered to -OUT
with FAIL SAFE enabled or to GND with FAIL SAFE disabled.
E721 7 532014 - Rev. D
5 PROGRAMMING Changes to the programming parameters
become effective as soon as they are
,WLVQHFHVVDU\WRDFFHVV352*5$00,1*PRGHLQRUGHU
carried out, while final memorisation
WRSURJUDPDXWRPDWHGV\VWHPRSHUDWLRQ occurs only upon exiting programming and
3URJUDPPLQJ LV GLYLGHG LQ WZR SDUWV VW /(9(/ DQG QG returning to the input state display. If the
/(9(/ unit is powered down before returning to
The status of the automated system is the input state display, all changes made
normally shown on the display. When will be lost.
push-button F is pressed or when F and
+ are pressed simultaneously, this gives It is possible to return to the input status
access to 1st or 2nd level programming. display and store all the parameters
During battery operation the display is off. modified to that moment from any point
Briefly press “+” to view the state of the of the 1st and 2nd level programming by
automated system. pressing keys F and - simultaneously.
ENGLISH
ENGLISH
50 PD[LPXPSRZHU
When the power value has been changed, it is advisable to perform a new
SETUP (see par. 7.3)
OPENING SPEED:
So $GMXVWVWKHPRWRURSHQLQJVSHHGWROHYHOV
08
01 PLQLPXPVSHHG
10 PD[LPXPVSHHG
When the speed value has been changed, it is advisable to perform a new
SETUP (see par. 7.3)
CLOSING SPEED:
Sc $GMXVWVWKHPRWRUFORVLQJVSHHGWROHYHOV
08
01 PLQLPXPVSHHG
10 PD[LPXPVSHHG
When the speed value has been changed, it is advisable to perform a new
SETUP (see par. 7.3)
SLOWING DURING OPENING
ro $GMXVWVWKHVORZLQJVSDFHDVDSHUFHQWDJHRIWKHWRWDOJDWHWUDYHO$GMXVWDEOHIURP5 ZLWK
20
VSHHG10 ZLWKVSHHGEHWZHHQDQG15 ZLWKVSHHG!WR99 LQVWHSV
5-10-15 PLQLPXPVORZLQJ
99 PD[LPXPVORZLQJ
SLOWING DURING CLOSING:
rc $GMXVWVWKHVORZLQJVSDFHDVDSHUFHQWDJHRIWKHWRWDOJDWHWUDYHO$GMXVWDEOHIURP5 ZLWK
20
VSHHG10 ZLWKVSHHGEHWZHHQDQG15 ZLWKVSHHG!WR99 LQVWHSV
5-10-15 PLQLPXPVORZLQJ
99 PD[LPXPVORZLQJ
SPEED DURING SLOWING:
Sr $GMXVWVJDWHVSHHGGXULQJVORZLQJ
0
0 /2:VSHHG
1 +,*+VSHHG
STATUS OF AUTOMATED SYSTEM:
St ([LWIURPSURJUDPPLQJGDWDVWRUDJHDQGUHWXUQWRJDWHVWDWXVGLVSOD\
00 &/26(' 07 )$,/6$)(LQSURJUHVV
01 23(1 08 %86($6<GHYLFHFKHFNLQSURJUHVV
02 6WRSWKHQ“23(1” 09 3UHIODVKLQJWKHQ“23(1”
03 6WRSWKHQ“&/26(” 10 3UHIODVKLQJWKHQ“&/26(”
04 ,Q“3$86(” 11 23(1LQ3DUWLDO2SHQLQJ
05 'XULQJRSHQLQJVWDJH 12 LQ3$86(3DUWLDO2SHQLQJ
06 'XULQJFORVLQJVWDJH
WDNHRII
Y DFWLYH
no H[FOXGHG
PREFLASHING:
PF $OORZVW\SHVRISUHIODVKLQJWREHVHOHFWHGZLWKDGXUDWLRQHTXDOWRVHFV
no
no QRSUHIODVKLQJ
OC SUHIODVKLQJEHIRUHHDFKPRYHPHQW
CL SUHIODVKLQJEHIRUHDFORVLQJPRYHPHQW
OP SUHIODVKLQJEHIRUHDQRSHQLQJPRYHPHQW
PA SUHIODVKLQJRQO\DWHQGRISDXVH
PREFLASHING TIME (visible only if preflashing is selected in the previous menu):
tP $GMXVWVSUHIODVKLQJWLPHIURP 1 WR10 VHFLQVHFRQGVWHSV
03
01 PLQLPXPSUHIODVKLQJ
10 PD[LPXPSUHIODVKLQJ
CLOSING PHOTOCELLS:
Ph $FWLYDWHWKHIXQFWLRQLI\RXZDQWWKHFORVLQJSKRWRFHOOVWRORFNPRYHPHQWDQGUHYHUVHLWRQ
no
GLVHQJDJHPHQW1RUPDOO\RSHUDWLRQRIWKHFORVLQJSKRWRFHOOVLPPHGLDWHO\SXWVWKHJDWH
LQWRUHYHUVHZKHQWKLVIXQFWLRQLVRII
Y UHYHUVDORQGLVHQJDJHPHQW
no LPPHGLDWHUHYHUVDOWRRSHQLQJ
Parameter not displayed in SLAVE mode
OPENING PHOTOCELLS:
oP $FWLYDWHWKHIXQFWLRQLI\RXZDQWWKHRSHQLQJSKRWRFHOOVWRORFNPRYHPHQWDQGUHYHUVHLW
no
GXULQJFORVLQJ1RUPDOO\ZLWKWKLVIXQFWLRQRIIRSHUDWLRQRIWKHRSHQLQJSKRWRFHOOVGHWHUPLQHV
WKHUHVXPSWLRQRIPRYHPHQWRQWKHLUGLVHQJDJHPHQW
no LPPHGLDWHUHYHUVDOWRFORVLQJ
no UHVXPSWLRQRIPRWLRQRQGLVHQJDJHPHQW
Parameter not displayed in SLAVE mode
ADMAP FUNCTION
Ad 3HUPLWVDFWLYDWLRQRIRSHUDWLRQLQDFFRUGDQFHZLWK)UHQFKVWDQGDUG1)3
no
Y DFWLYH
no H[FOXGHG
ENCODER:
EC 7KHYLUWXDOHQFRGHURQWKHERDUGRSHUDWHVDVDQDQWLFUXVKLQJGHYLFHDQGPDQDJHVWKH
02
VORZLQJDQGSDUWLDORSHQLQJVWDUWSRLQWV
,IWKHJDWHVWULNHVDQREVWDFOHGXULQJWKHRSHQLQJRUFORVLQJVWDJHWKHYLUWXDOHQFRGHUFDXVHV
UHYHUVDORIWKHPRWLRQ7KHVHFRQGREVWDFOHGHWHFWHGLQWKHVDPHGLUHFWLRQFDXVHVWKHPRWRU
WRVWRS$QDODUPLVVLJQDOOHGLQERWKFDVHVVHHVHFWLRQRQDODUPV
,WLVQHFHVVDU\WRDGMXVWWKHVHQVLWLYLW\RIWKHYLUWXDOHQFRGHUE\YDU\LQJWKHWLPHWKDWWKH
ERDUGZDLWVIRUEHIRUHFRQWUROOLQJUHYHUVDORIPRWLRQIURPDPLQLPXPRI0 VHFWRDPD[LPXP
RI10 VHFLQRQHVHFRQGVWHSV
00 PD[LPXPVHQVLWLYLW\
10 PLQLPXPVHQVLWLYLW\
E721 10 532014 - Rev. D
Display Function Default 1
PARTIAL OPENING:
PO ,WLVSRVVLEOHWRDGMXVWWKHZLGWKRIWKHSDUWLDOOHDIRSHQLQJDVDSHUFHQWDJHRIWKHWRWDOJDWH
50
WUDYHO
$GMXVWDEOHIURPWRLQVWHSV
00 QRSDUWLDORSHQLQJ
01 PLQLPXPSDUWLDORSHQLQJ
99 PD[LPXPSDUWLDORSHQLQJ
TIME-OUT
t ,WLVDGYLVDEOHWRVHWDYDOXHKLJKHUWKDQWKHWLPHWDNHQE\WKHJDWHWRRSHQRUFORVHIXOO\
2.0
$GMXVWDEOHIURP 0 WR59 VHFLQVHFRQGVWHSV6XEVHTXHQWO\GLVSOD\FKDQJHVWRPLQXWHV
DQGWHQVRIVHFRQGVVHSDUDWHGE\DSRLQWDQGWLPHLVDGMXVWHGLQVHFRQGVWHSVXSWR
ENGLISH
WKHPD[LPXPYDOXHRI9.5 PLQXWHV
(JLIWKHGLVSOD\VKRZV2.5 SDXVHWLPHLVPLQDQGVHFV
When using a system with MASTER/SLAVE configuration you must set a WORK TIME
on the MASTER unit that takes into account the movement time of both leaves.
OUT 1:
o1 $OORZVRXWSXW287RSHQFROOHFWRU12WREHDFWLYDWHGLQRQHRIWKHIROORZLQJIXQFWLRQV
00
00 $OZD\VHQDEOHGVXSSOLHV9YROWDJH ZLWKDPD[DEVRUSWLRQRIP$
01 )$,/6$)(PRQLWRUVWKHFRUUHFWRSHUDWLRQRIWKHFRQQHFWHGWUDGLWLRQDOSKRWRFHOOV
02 :$51,1*/,*+7RIIZKHQFORVHGRQGXULQJRSHQLQJDQGRSHQSDXVHIODVKLQJGXULQJFORVLQJ
03 &2857(6</,*+7VHHQH[WIXQFWLRQ
04 $/$50%$77(5<RSHUDWLRQ
05 JDWH23(1RU3$86('
06 JDWH&/26('
07 JDWHLQ027,21
08 JDWH23(1,1*
09 JDWH&/26,1*
1 0 $&7,9(VDIHW\
1 1 WLPHGRXWSXWWKDWFDQEHDFWLYDWHGE\VHFRQGUDGLRFKDQQHOVHHQH[WIXQFWLRQ
1 2 RXWSXWWKDWFDQEHDFWLYDWHGE\VHFRQGUDGLRFKDQQHOVWHSIXQFWLRQ
t1 TIMING OF OUT 1 (only if option 03 or 11 is selected at the previous step):
&DQ EH XVHG WR DGMXVW WLPLQJ RI RXWSXW 287 LI D WLPHG IXQFWLRQ ZDV VHOHFWHG
02
HJ03 RU 11 IURP1 WR99 PLQXWHVLQPLQXWHVWHSV
OPEN B / CLOSE / EDGE SAFETY DEVICE:
Ob ,WLVSRVVLEOHWRVHOHFWWKHXVHRI23(1%LQSXWDVSDUWLDORSHQLQJ&/26(FRPPDQGRU('*( 00
6$)(7<'(9,&(
00 23(1%
01 &/26(
02 6$)(7<('*(6$)(7<1&FRQWDFW
If you select a function logic that involves the use of the CLOSE command (logic b,
bC, C) this function will be preset to 01 and it will not be possible to change it.
STOP / EDGE SAFETY DEVICE
SP ,WLVSRVVLEOHWRVHOHFWWKHXVHRI6723LQSXWDV6723RU('*(6$)(7<'(9,&( 00
00 6723
01 6$)(7<('*(6$)(7<1&FRQWDFW
PARTIAL REVERSE:
IP ,WLVSRVVLEOHWRVHWWKHUHYHUVHW\SHFRPSOHWHRUSDUWLDOZKHQDQREVWDFOHLVHQFRXQWHUHG no
RUZKHQDVDIHW\HGJHLVWULJJHUHG
Y 3DUWLDOUHYHUVHDFWLYDWLRQ:KHQDQREVWDFOHLVHQFRXQWHUHGRUZKHQDVDIHW\HGJH
LVWULJJHUHGWKHOHDIUHYHUVHVPRYHPHQWIRUDSSUR[LPDWHO\”DQGZLOOWKHQVWRS
no 3DUWLDOUHYHUVHGHDFWLYDWLRQ:KHQDQREVWDFOHLVHQFRXQWHUHGRUZKHQDOHDIVDIHW\
HGJHLVWULJJHUHGLWFRPSOHWHO\UHYHUVHVPRYHPHQWDQGZLOOSODFHLWVHOILQRSHQRU
FORVHGSRVLWLRQ
MOTOR LOCK:
Lc ,WLVSRVVLEOHWRVHOHFWWKHXVHRIWKHPRWRUORFNGXULQJEDWWHU\RSHUDWLRQ Y
Y WKHPRWRUORFNFRQWLQXHVWRRSHUDWHUHJXODUO\HYHQGXULQJEDWWHU\RSHUDWLRQ
no ZKHQWKHV\VWHPVZLWFKHVWREDWWHU\RSHUDWLRQWKHPRWRUORFNUHPDLQVRSHQ
,I AS Y WKHGLVSOD\LQGLFDWHVWKHQXPEHURIWKRXVDQGVRIF\FOHVDIWHUZKLFKVHUYLFHLV
UHTXLUHGPD\EHVHWIURP0 WR99
,IAS no WKHGLVSOD\LQGLFDWHVWKHQXPEHURIWKRXVDQGVRIF\FOHVSHUIRUPHG7KHYDOXH
GLVSOD\HGLVXSGDWHGZLWKWKHVHTXHQFHRIF\FOHVLQWHUDFWLQJZLWKWKHYDOXHRInd
If AS = no press keys + and - for 5 sec. to zero the cycle counter.
CYCLE PROGRAMMING (TENS):
nd ,IAS Y WKHGLVSOD\LQGLFDWHVWKHQXPEHURIWHQVRIF\FOHVDIWHUZKLFKVHUYLFHLVUHTXLUHG
00
PD\EHVHWIURP0 WR99
,IAS no WKHGLVSOD\LQGLFDWHVWKHQXPEHURIWHQVRIF\FOHVSHUIRUPHG7KHYDOXHGLVSOD\HG
LVXSGDWHGZLWKWKHVHTXHQFHRIF\FOHVLQWHUDFWLQJZLWKWKHYDOXHRInc
Example: if the system has performed 11.218, it will display nc = 11 and
nd = 21
STATUS OF AUTOMATED SYSTEM:
St ([LWIURPSURJUDPPLQJGDWDVWRUDJHDQGUHWXUQWRJDWHVWDWXVGLVSOD\
00 &/26(' 07 )$,/6$)(LQSURJUHVV
01 23(1 08 %86($6<GHYLFHFKHFNLQSURJUHVV
02 6WRSWKHQ“23(1” 09 3UHIODVKLQJWKHQ“23(1”
03 6WRSWKHQ“&/26(” 10 3UHIODVKLQJWKHQ“&/26(”
04 ,Q“3$86(” 11 23(1LQ3DUWLDO2SHQLQJ
05 'XULQJRSHQLQJVWDJH 12 LQ3$86(3DUWLDO2SHQLQJ
06 'XULQJFORVLQJVWDJH
ENGLISH
3UHVVDQGKROGGRZQSXVKEXWWRQ+6:RU-6: :LWKLQWKLVVHFRQGSHULRGSUHVVWKHUHTXLUHGSXVK
DQGWKHQSUHVVWKH6(783SXVKEXWWRQ6:WRVWRUH EXWWRQRQWKH/&5&UHPRWHFRQWURO
WRWDO RSHQLQJ 23(1 $ RU SDUWLDO RSHQLQJ 23(1 % 7KH/('ZLOOFRPHRQZLWKDIL[HGOLJKWIRUVHFRQG
&/26(UHVSHFWLYHO\7KHFRUUHVSRQGLQJ/('ZLOOEHJLQ LQGLFDWLQJ WKDW WKH XQLW KDV EHHQ VWRUHG DQG WKHQ
WRIODVKVORZO\IRUVHFV UHVXPH IODVKLQJ IRU DQ DGGLWLRQDO VHFRQGV GXULQJ
5HOHDVHERWKSXVKEXWWRQV ZKLFKWLPHDQRWKHUUDGLRFRQWUROPD\EHVWRUHG
:LWKLQWKLVVHFSHULRGZKLOHWKHUDGLRFRQWURO/('LVVWLOO 2QFH WKH VHFRQGV DUH XS WKH /(' ZLOO JR RII WR
IODVKLQJSUHVVDQGKROGGRZQWKHUHTXLUHGSXVKEXWWRQ LQGLFDWHWKDWWKHSURFHGXUHLVFRPSOHWH
RQWKHUDGLRFRQWUROWKHUDGLRFRQWURO/('ZLOOFRPHRQ
ZLWKDIL[HGOLJKW 6.3.1 STORING LC/RC RADIOCONTROLS REMOTELY
7KHFRUUHVSRQGLQJ/('ZLOOFRPHRQZLWKDIL[HGOLJKW :LWK /&5& UDGLRFRQWUROV RWKHU UDGLRFRQWUROV PD\ EH
IRUVHFRQGVDQGWKHQJRRIIWRLQGLFDWHWKHVHWWLQJ VWRUHGLQUHPRWHPRGHLHZLWKRXWRSHUDWLQJGLUHFWO\RQ
KDVEHHQVWRUHG WKHERDUGXVLQJDSUHYLRXVO\VWRUHGUDGLRFRQWURO
5HOHDVHWKHUDGLRFRQWUROSXVKEXWWRQ 2EWDLQ D UDGLRFRQWURO DOUHDG\ VWRUHG RQ RQH RI LWV
FKDQQHOV23(1$RU23(1%&/26(
3UHVVWKHVWRUHGUDGLRFRQWUROSXVKEXWWRQWZLFHLQTXLFN
VXFFHVVLRQ 3UHVVDQGKROGGRZQSXVKEXWWRQV3DQG3VLPXOWD
QHRXVO\XQWLOERWK/('VIODVKVORZO\IRUVHFV
The automated system will carry out an :LWKLQVHFRQGVSXVKWKHSUHYLRXVO\VWRUHGUDGLRFRQ
opening control. Ensure the automated WUROSXVKEXWWRQWRDFWLYDWHWKHOHDUQLQJVWDJHRQWKH
device is free of any obstacle by people VHOHFWHGFKDQQHO
or things.
7KH/('RQWKHERDUGFRUUHVSRQGLQJWRWKHFKDQQHO
7RHQDEOHRWKHUUDGLRFRQWUROVZLWKWKHVDPHV\VWHPFRGH EHLQJVWRUHGIODVKHVIRUVHFRQGVZLWKLQZKLFKWLPH
WUDQVIHUWKHV\VWHPFRGHRIWKHVWRUHGUDGLRFRQWUROSXVK WKHFRGHRIDQRWKHUUDGLRFRQWUROPXVWEHVHQW
EXWWRQWRWKHFRUUHVSRQGLQJSXVKEXWWRQRIWKHUDGLRFRQ 7KH/('ZLOOFRPHRQZLWKDIL[HGOLJKWIRUVHFRQG
WUROVWREHDGGHGIROORZLQJWKHSURFHGXUHEHORZ LQGLFDWLQJ WKDW WKH XQLW KDV EHHQ VWRUHG DQG WKHQ
D 2QWKHVWRUHGUDGLRFRQWUROSUHVVDQGKROGGRZQ UHVXPH IODVKLQJ IRU DQ DGGLWLRQDO VHFRQGV GXULQJ
3DQG3VLPXOWDQHRXVO\ ZKLFK WLPH RWKHU UDGLRFRQWUROV PD\ EH VWRUHG DQG
E 7KHUDGLRFRQWURO/('ZLOOEHJLQWRIODVK WKHQLWZLOOJRRII
F 5HOHDVHERWKSXVKEXWWRQV
6.4 RADIOCONTROLS DELETION PROCEDURE
G 3UHVVWKHVWRUHGSXVKEXWWRQDQGKROGGRZQWKH
7R GHOHWH ALL WKH FRGHV RI WKH UDGLRFRQWUROV HQWHUHG
UDGLRFRQWURO/('ZLOOFRPHRQZLWKDIL[HGOLJKW
VLPSO\SUHVVGRZQWRJHWKHUWKHWZRSXVKEXWWRQV+6:
H %ULQJWKHUDGLRFRQWUROVFORVHUWRRQHDQRWKHUSUHVV DQG-6:WKHQSUHVVWKH6(783SXVKEXWWRQ6:IRU
DQGKROGGRZQWKHFRUUHVSRQGLQJSXVKEXWWRQRI VHFRQGDQGKROGWKHILUVWWZRSXVKEXWWRQVSUHVVHGIRU
WKHUDGLRFRQWUROWREHDGGHGUHOHDVLQJRQO\RQFH VHFV
WKH/('RQWKHUDGLRFRQWUROKDVLVVXHGDGRXEOH 7KH /('V 5$',2 DQG 5$',2 ZLOO IODVK TXLFNO\ IRU
IODVKWRLQGLFDWHWKDWLWKDVEHHQVWRUHG VHFV
I 3UHVVWKHVWRUHGUDGLRFRQWUROSXVKEXWWRQWZLFHLQ 7KH/('VZLOOFRPHRQZLWKDIL[HGOLJKWIRUVHFRQGV
TXLFNVXFFHVVLRQ DQGWKHQJRRIIGHOHWLRQFDUULHGRXW
The automated system will carry out an 5HOHDVHERWKSXVKEXWWRQV
opening control. Ensure the automated
device is free of any obstacle by people This operation is NOT reversible. All the codes
or things. of the radiocontrols stored as OPEN A and
as OPEN B/CLOSE will be deleted.
< (1) F
BUS 2EASY
< (2)
ENGLISH
< OPEN A -
< GND
< OPEN B / CLOSE < SAFE
+
R
A
C
1
RADIO XF
R
2
IO
E
FC
FC
IO
O
< STOP / SAFE
W
R
D
O
R
A
P
R
< FSW OP
R
SETUP
< GND
< FSW CL
< +24
USB
BATTERY
RELEASE
Y
R
)
R
F
OUT
-L
E
S
S
E IN
TO
R M
K
K
K
T
-N
N
T EC
C
T
T RI
C
C
(P A
- +
A
LO
LA
LO
LO
M
R
P
M
B
<
<
<
<
<
<
<
<
<
)LJ
/HGV)&$DQG)&&UHSUHVHQWWKH1&FRQWDFWVRIWKHOLPLW The STOP (SAFE), FSW CL, FSW OP, OPEN B inputs
VZLWFKEXLOWLQWRWKHERDUGWKDWRSHQZKHQHQJDJHGDQG configured as SAFE are safety inputs with N.C.
WXUQRIIWKHDVVRFLDWHG/(' (Normally Closed) contact and therefore the
corresponding LEDs must be ON when the
automated system is at rest, and off when
$XWRPDWHG V\VWHP )&$ the connected device is used.
&/26(' )&& )&&HQJDJHG
The OPEN A, OPEN B/CLOSE inputs are inputs
$XWRPDWHG V\VWHP )&$ )&$HQJDJHG with N.O. (Normally Open) contact and
23(1 therefore the corresponding LEDs must be
)&&
OFF when the automated system is at rest,
and on when the connected device is used.
Tab. 3 - Description of POWER LED
When using equipment programmed as
Fixed ON 0DLQVSRZHUHG SLAVE the LEDs corresponding to terminal
board J13 must be off.
Flashing %DWWHU\SRZHUHG
ERROR LED flashing indicates alarm in
progress (situation does not impair gate
Off %RDUGRII operation)
ERROR LED on with a fixed light indicates
an error in progress (situation that locks
operation until the cause of the error has
7.2 BATTERY OPERATION been removed)
ATTENTION
7RRSWLPLVHHQHUJ\FRQVXPSWLRQDQGSURWHFWWKHFKDUJHGXULQJEDWWHU\RSHUDWLRQZKHQWKHDXWRPDWHGV\VWHPLV
VWRSSHGDQGWKHV\VWHPLVRQVWDQGE\WKH/&'GLVSOD\WKH%86HDV\/('DQGWKH)&&DQG)&$/('ZLOOEHRII
ZKLOHWKH32:(5/('IODVKHV
,QWKLVSKDVHLWLVLQDQ\FDVHSRVVLEOHWRYLHZWKHVWDWHRIWKHDXWRPDWHGV\VWHP7RGRWKLVLWLVVXIILFLHQWWREULHIO\SUHVV
“”RQWKHERDUG)ROORZLQJEULHISUHVVXUHWKH/&'GLVSOD\VKRZVWKHVWDWHRIWKHDXWRPDWHGV\VWHPIRUDSSUR[LPDWHO\
VHFRQGVWRWKHQJRRIIDJDLQ,QVWHDGGXULQJQRUPDORSHUDWLRQDOOWKHGLDJQRVWLF/('VDQGWKHGLVSOD\VWDWHVLJQDOV
EHFRPHFRQVLVWHQWZLWKWKHVWDWHRIWKHDXWRPDWHGV\VWHPVHH)LJ
E721 14 532014 - Rev. D
7.3 POSITIONING LIMIT SWITCHES
To ensure correct positioning of the limit switch magnets, the control unit must be installed and
correctly connected with all control and safety accessories.
7KHRSHUDWRULVHTXLSSHGZLWKDPDJQHWLFOLPLWVZLWFKVHQVRUEXLOWGLUHFWO\LQWRWKHHOHFWURQLFFRQWUROERDUG
7KHJDWHLVVWRSSHGGXULQJRSHQLQJRUFORVLQJZKHQWKHSRODULVHGPDJQHWVHFXUHGWRWKHXSSHUSDUWRIWKHUDFN
DFWLYDWHVWKHVHQVRU
&KHFNWKDWWKHRSHUDWRULVVHWIRUPDQXDORSHUDWLQJPRGHDVGHVFULEHGLQWKHLQVWUXFWLRQV
IRUWKHRSHUDWRU
0RYHWKHJDWHWRopeningSRVLWLRQPDQXDOO\OHDYLQJPPIURPWKHOLPLWVZLWFKPH
FKDQLFDOVWRSVHH)LJ
A
C
R O1
2
FC
FC
IO
6OLGHWKHPDJQHWZLWKWKHCIRCLERQWKHUDFNLQWKHGLUHFWLRQRIWKHPRWRU$VVRRQDV
I
D
ENGLISH
A
E
R
WKH/('IRUWKH)&$OLPLWVZLWFKRQWKHERDUGJRHVRIIVHFXUHZLWKWKHDSSURSULDWHVFUHZV
0RYHWKHJDWHWRclosingSRVLWLRQPDQXDOO\OHDYLQJPPIURPWKHOLPLWVZLWFKPH
FKDQLFDOVWRS
6OLGHWKHPDJQHWZLWKWKHSQUARERQWKHUDFNLQWKHGLUHFWLRQRIWKHPRWRU$VVRRQDV
WKH/('IRUWKH)&&OLPLWVZLWFKRQWKHERDUGJRHVRIIVHFXUHZLWKWKHDSSURSULDWHVFUHZV
&KHFNWKDWWKHUHOHYDQWOLPLWVZLWFK/('JRHVRIIFRUUHFWO\DWWKHHQGRIWKHRSHQLQJDQG
A
C
R O1
2
FC
FC
IO
I
FORVLQJPRYHPHQWDQGPDNHWKHQHFHVVDU\FKDQJHVWRWKHSRVLWLRQRIWKHOLPLWVZLWFK
R
A
E
R
PDJQHWSRVLWLRQLIQHFHVVDU\
To avoid damage to the operator and/or interruptions in the operation of the
automated system, approximately 40 mm must be left from the mechanical
limit switch stops.
)LJ
MASTER/SLAVE
)LJ
Avoid any type of connection and wiring to terminal board J13 of the SLAVE unit.
The BUS connection between the two boards must be POLARISED following the sequence of the
poles of the J12 terminal board (POLE (1) - POLE (2)) - (see Fig. 19).
When a unit is configured as a SLAVE, this will force the values of some programming parameters
no longer displayed in the menu (LO-PA-Pb-Ph-Op). By placing the board in MASTER mode
again, the previously forced values are stored in the program.
(1) (1)
BUS 2 EASY BUS 2 EASY
(2) (2)
'RQRWFRQQHFW
DQ\WKLQJWRWKLV
WHUPLQDOERDUG
The SETUP request signalled by the flashing S0 on the display can occur both on the MASTER unit
and on the SLAVE unit. In the latter case, the MASTER unit will display an error 91 . In any case, the
SETUP procedure can only be started from the MASTER unit.
7R6(783D0$67(56/$9(V\VWHPIROORZWKHVWHSVEHORZ
In case of error or non-completion of the above-mentioned SETUP procedure, you must repeat it
completely starting from point no.1.
ENGLISH
successful SETUP) and check that both the FCA and 7DELQGLFDWHVDOOWKHDODUPVWKDWPD\EHVKRZQRQWKH
FCC LEDs are on. Otherwise, the board will signal GLVSOD\
error 12 (see tab. 5)
3UHVVDQGKROGWKH6(7836:SXVKEXWWRQXQWLOWKH Tab. 4 - Alarms
JDWHEHJLQVWRPRYHVORZO\DQGVWRSVZKHQLWUHDFKHV
WKHOLPLWVZLWFK,IWKHOLPLWVZLWFKUHDFKHGLVWKHFORVLQJ 22 /LPLWHG02725FXUUHQW
VZLWFKZLWKWKHSQUAREWKHGHYLFHVWRUHVWKDWSRLQW 24 /$03RXWSXWVKRUWFLUFXLWHG
DVWKHclosingVWRSFRQYHUVHO\LIWKHOLPLWVZLWFKLVWKH
RSHQLQJ VZLWFK ZLWK WKH CIRCLE WKH GHYLFH VWRUHV
27 2EVWDFOHGHWHFWLRQYLVLEOHIRUVHFV
;)UDGLRFRGHPHPRU\PRGXOHIXOOYLVLEOH
WKDWSRLQWDVWKHopeningVWRS'XULQJWKDWVWDJHS 1 30 IRUVHFV
IODVKHVRQWKHGLVSOD\
7KHJDWHDXWRPDWLFDOO\EHJLQVWRPRYHVORZO\LQWKH 40 6HUYLFHUHTXHVW
RSSRVLWHGLUHFWLRQDQGWKHQVWRSVZKHQLWUHDFKHVWKH 46 )RUFHGGHIDXOWSURJUDPPLQJUHVHW
OLPLWVZLWFK,IWKHOLPLWVZLWFKUHDFKHGLVWKHRSHQLQJ
VZLWFKZLWKWKHSQUAREWKHGHYLFHVWRUHVWKDWSRLQW
9.2 ERRORS
DVWKHopeningVWRSFRQYHUVHO\LIWKHOLPLWVZLWFKLV When an ERROR occurs, LED DL20 comes
WKHFORVLQJVZLWFKZLWKWKHSQUAREWKHGHYLFHVWRUHV on with a fixed light and a number relating
WKDW SRLQW DV WKH closing VWRS 'XULQJ WKDW VWDJH to the current fault appears on the display
S 3 IODVKHVRQWKHGLVSOD\ when the + and - keys are pressed.
$FFRUGLQJ WR WKH ILQDO OLPLW VZLWFK UHDFKHG WKH GH 7DELQGLFDWHVDOOWKHHUURUVWKDWPD\EHVKRZQRQWKH
YLFHWDNHVXSDVWDWXVRIFORVHG0 0 RURSHQ0 1 GLVSOD\
,QWKHVHFRQGFDVHLVVXHDQ23(1SXOVHWRFORVHWKH
JDWH Tab. 5 - Errors
01 %RDUGIDXOW\
03 0RWRUIDXOW\
8 TESTING THE AUTOMATED SYSTEM 0RWRUORFNORFNHGFORVHGFKHFNWKHPRWRU
$IWHULQVWDOODWLRQDQGSURJUDPPLQJFKHFNWKHV\VWHPLV 06 ORFNDQGUHSODFHLIQHFHVVDU\
RSHUDWLQJFRUUHFWO\$ERYHDOOFKHFNWKDWWKHVDIHW\GH *DWHWRRKHDY\RUWRRPXFKIULFWLRQWU\WR
YLFHVRSHUDWHFRUUHFWO\DQGHQVXUHWKDWWKHFXUUHQWVDIHW\ 07 LQFUHDVHPRWRUSRZHU
UHJXODWLRQVDUHPHW %86($6<GHYLFHHUURUHJVDPHDGGUHVV
08 RQWZRSKRWRFHOOSDLUVFKHFNDGGUHVV
10 %RWKOLPLWVZLWFKHVZLWKWKHVDPHSRODULW\
Remember that the second programming /LPLWVZLWFKHQJDJHGDWWKHEHJLQQLQJRI
level features the encoder configuration 12 6(783
parameter (parameter EC). This “virtual”
encoder located on the board acts as 15 7LPHRXWILQLVKHG
an anti-crushing device. During the open/ 1RFRPPXQLFDWLRQZLWKWKH6/$9(XQLW
closing phase, should the gate collide 90 6/$9(XQLWPLVVLQJ
with an obstacle, the “virtual” encoder
will cause the motion to reverse. At the 91 (UURURQWKH6/$9(XQLW
next motion in the same direction, an 92 (UURURQWKH6/$9(XQLW
obstacle in the same position will cause
the motor to stop. It is essential to correctly Errors 9 0 9 1 and 9 2 are displayed
configure this parameter to adjust the only on E721 configured as MASTER and
correct sensitivity of the “virtual” encoder in particular 9 1 and 9 2 indicate errors
with respect to obstacles during motion. present on the SLAVE unit. Should such
errors be displayed, we recommend you
check on the SLAVE unit the type of error
shown on the display to solve it and restore
correct operation of the system.
ORFNVDQGRSHQVRQ
'85,1*23(1,1* ORFNVRSHUDWLRQ ORFNVRSHUDWLRQ UHFORVHVWKHJDWH ORFNVRSHUDWLRQ VHHQGOHYHOSURJ QRHIIHFW GLVHQJDJHPHQW23(1
ORFNVVWRUHV&/26(
ORFNVDQGRSHQVRQ
UHYHUVHVWRRSHQLQJVHH GLVHQJDJHPHQW23(1
'85,1*&/26,1* UHRSHQVWKHJDWH UHRSHQVWKHJDWH QRHIIHFW ORFNVRSHUDWLRQ QRHIIHFW QGOHYHOSURJ ORFNVVWRUHV&/26(
ORFNVDQGRSHQVRQ
DURING OPENING ORFNVRSHUDWLRQ ORFNVRSHUDWLRQ UHFORVHVWKHJDWH ORFNVRSHUDWLRQ VHHQGOHYHOSURJ QRHIIHFW GLVHQJDJHPHQW23(1
ORFNVVWRUHV&/26(
ORFNVDQGRSHQVRQ
UHYHUVHVWRRSHQLQJVHH GLVHQJDJHPHQW23(1
DURING CLOSING ORFNVRSHUDWLRQ ORFNVRSHUDWLRQ QRHIIHFW ORFNVRSHUDWLRQ QRHIIHFW QGOHYHOSURJ ORFNVVWRUHV&/26(
UHVXPHVPRWLRQLQUHYHUVH UHVXPHVPRWLRQLQUHYHUVH QRHIIHFW QRHIIHFW QRHIIHFW QRHIIHFW23(1ORFNV
LOCKED GLUHFWLRQ$IWHU6723DOZD\V GLUHFWLRQ$IWHU6723DOZD\V FORVHVWKHJDWH 23(1&/26(LQKLELWHG 23(1LQKLELWHG &/26(LQKLELWHG VWRUHV&/26(
FORVHV FORVHV
LOGIC "A" PULSES
STATUS OF AUTOMATED SYSTEM OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
RSHQVWKHJDWHSDUWLDOO\
RSHQVDQGUHFORVHVDIWHU DQGFORVHVLWDIWHUSDXVH QRHIIHFW QRHIIHFW QRHIIHFW
CLOSED WKHSDXVHWLPH QRHIIHFW 23(1LQKLELWHG 23(1LQKLELWHG QRHIIHFW 23(1LQKLELWHG
WLPH%
ORFNVDQGRSHQVRQ
DURING OPENING QRHIIHFW QRHIIHFW UHFORVHVWKHJDWH ORFNVRSHUDWLRQ VHHQGOHYHOSURJ QRHIIHFW GLVHQJDJHPHQW
VWRUHV&/26(
FRQWLQXHVWRRSHQDQG ORFNVDQGRSHQVRQ
DURING OPENING QRHIIHFW QRHIIHFW UHFORVHVWKHJDWH ORFNVRSHUDWLRQ VHHQGOHYHOSURJ UHFORVHVLPPHGLDWHO\ GLVHQJDJHPHQW
VWRUHV&/26(
DURING CLOSING UHRSHQVWKHJDWH UHRSHQVWKHJDWH QRHIIHFW ORFNVRSHUDWLRQ QRHIIHFW UHYHUVHVWRRSHQLQJVHH GLOVRHQJDJHPHQW23(1
FNVDQGRSHQVRQ
QGOHYHOSURJ ORFNVVWRUHV&/26(
ENGLISH
LOCKED FORVHVWKHJDWH FORVHVWKHJDWH FORVHVWKHJDWH 23(1&/26(LQKLELWHG 23(1LQKLELWHG &/26(LQKLELWHG 23(1&/26(LQKLELWHG
DURING OPENING UHYHUVHVWRFORVLQJ UHYHUVHVWRFORVLQJ UHFORVHVWKHJDWH ORFNVRSHUDWLRQ VHHQGOHYHOSURJ FRQWLQXHVWRRSHQDQG RQGLOVRHQJDJHPHQWVWRUHV
FNVDQGRSHQV
UHFORVHVLPPHGLDWHO\ &/26(
FRQWLQXHVWRRSHQDQG ORFNVDQGRQGLVHQJDJHPHQW
DURING OPENING ORFNVRSHUDWLRQ ORFNVRSHUDWLRQ UHFORVHVWKHJDWH ORFNVRSHUDWLRQ VHHQGOHYHOSURJ UHFORVHVLPPHGLDWHO\
RSHQVDQGDWWKHHQGLPPHGLDWHO\
FORVHV23(1ORFNVVWRUHV&/26(
'XULQJWKHSDUWLDORSHQLQJF\FOHDQ23(1$SXOVHFDXVHVWRWDORSHQLQJ
E721 19 532014 - Rev. D
LOGIC "SA" PULSES
STATUS OF AUTOMATED SYSTEM OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
2SHQVWKHJDWHSDUWLDO \
RSHQVDQGUHFORVHVDIWHU DQGFO QRHIIHFW QRHIIHFW QRHIIHFW
CLOSED WKHSDXVHWLPH RVHVLWDIWHUSDXVH QRHIIHFW 23(1LQKLELWHG 23(1LQKLELWHG QRHIIHFW 23(1LQKLELWHG
WLPH%
ORFNVDQGRSHQVRQ
DURING OPENING QRHIIHFW QRHIIHFW UHFORVHVWKHJDWH ORFNVRSHUDWLRQ VHHQGOHYHOSURJ QRHIIHFW GLVHQJDJHPHQW
VWRUHV&/26(
ORFNVDQGRSHQVRQ
DURING OPENING QRHIIHFW / FORVHVWKHJDWH ORFNVRSHUDWLRQ VHHQGOHYHOSURJ QRHIIHFW GLVHQJDJHPHQWVWRUHV
23(1&/26(
DURING CLOSING RSHQVWKHJDWH / QRHIIHFW ORFNVRSHUDWLRQ QRHIIHFW UHYHUVHVWRRSHQLQJVHH GLOVRHQJDJHPHQWVWRUHV
FNVDQGRSHQVRQ
QGOHYHOSURJ 23(1&/26(
ORFNVDQGRSHQVRQ
DURING OPENING QRHIIHFW / FORVHVWKHJDWH ORFNVRSHUDWLRQ VHHQGOHYHOSURJ QRHIIHFW GLVHQJDJHPHQWVWRUHV
23(1&/26(
DURING CLOSING RSHQVWKHJDWH / QRHIIHFW ORFNVRSHUDWLRQ QRHIIHFW UHYHUVHVWRRSHQLQJVHH GLOVRHQJDJHPHQWVWRUHV
FNVDQGRSHQVRQ
QGOHYHOSURJ 23(1&/26(
FRANÇAIS
7 MISE EN SERVICE ........................................................................................................................................... 14
7.1 CONTRÔLE DES LEDS ................................................................................................................................................ 14
7.2 FONCTIONNEMENT À BATTERIE ................................................................................................................. 14
7.3. POSITIONNEMENT DES FINS DE COURSE.................................................................................................................. 15
7.4 CONFIGURATION MASTER/SLAVE ............................................................................................................................ 16
7.4.1 CÂBLAGES MASTER-SLAVE ........................................................................................................................................ 16
7.4.2 PROCÉDURE DE SETUP MASTER-SLAVE ....................................................................................................................... 16
7.5 SETUP ....................................................................................................................................................................... 17
8 TEST DE L'AUTOMATISME ........................................................................................................................... 17
9 SIGNALISATION D'ALARMES ET D'ANOMALIES ................................................................................................ 17
9.1 ALARMES ................................................................................................................................................................ 17
9.2 ERREURS .................................................................................................................................................................. 17
10 LOGIQUES DE FONCTIONNEMENT ............................................................................................................... 18
DÉCLARATION CE DE CONFORMITÉ
Fabricant : )$$&6S$
Adresse : 9LD&DODUL=ROD3UHGRVD%2/2*1(,7$/,(
Déclare que : /·DSSDUHLOODJHpOHFWURQLTXH(
HVWFRQIRUPHDX[FRQGLWLRQVUHTXLVHVHVVHQWLHOOHVGHVpFXULWpGHVGLUHFWLYHV&((
VXLYDQWHV
&('LUHFWLYH%DVVH7HQVLRQ
&('LUHFWLYHVXUOD&RPSDWLELOLWppOHFWURPDJQpWLTXH
1RWHVXSSOpPHQWDLUH
&HSURGXLWDpWpVRXPLVjGHVWHVWVGDQVXQHFRQILJXUDWLRQW\SLTXH
KRPRJqQHWRXVOHVSURGXLWVVRQWIDEULTXpVSDU)$$&6S$
%RORJQH
/
$GPLQLVWUDWHXU'pOpJXp
$0DUFHOODQ
AVERTISSEMENTS
$WWHQWLRQ,OHVWLPSRUWDQWSRXUODVpFXULWpGHVSHUVRQQHVGHVXLYUHjODOHWWUHWRXWHVOHVLQVWUXFWLRQV
8QH LQVWDOODWLRQ HUURQpH RX XQH XWLOLVDWLRQ HUURQpH GX SURGXLW SHXW SURYRTXHU GH JUDYHV GRPPDJHV DX[
SHUVRQQHV
/LUHDWWHQWLYHPHQWOHVLQVWUXFWLRQVDYDQWGHGpEXWHUO
LQVWDOODWLRQGXSURGXLWHWOHVFRQVHUYHUSRXUUpIpUHQFHVXOWpULHXUHV
/H V\PEROH PHW HQ pYLGHQFH OHV QRWHV LPSRUWDQWHV SRXU OD VpFXULWp GHV SHUVRQQHV HW O
LQWpJULWp GH
O
DXWRPDWLVPH
/HV\PEROH DWWLUHO
DWWHQWLRQVXUOHVQRWHVUHODWLYHVDX[FDUDFWpULVWLTXHVRXDXIRQFWLRQQHPHQWGXSURGXLW
2 PRÉSENTATION ET COMPOSANTS
FRANÇAIS
/ SAFE
/ SAFE
CAPTEUR
FIN DE COURSE
)LJ
FRANÇAIS
jSDVª$XWRPDWLTXHDYHFLQYHUVLRQHQ
- &211(&7(85'
(175e(6(1%251,(5 SDXVH6HPLDXWRPDWLTXH©Eª/RJLTXH
&211(&7(85'802'8/(5e&(37(855$',23285 PL[WH©E&ª+RPPHSUpVHQW
- Durée de fonc- 3URJUDPPDEOHGHjPLQ
201,'(&
tionnement
/&' e&5$1'(6,*1$/,6$7,21(7352*5$00$7,21
Temps de pause 3URJUDPPDEOHGHjPLQ
) )86,%/('(3527(&7,21 OPEN A / OPEN B
2.2 DESCRIPTION BORNIER J13 Force moteur 3URJUDPPDEOHVXUQLYHDX[
Vitesse du moteur 3URJUDPPDEOHVXUQLYHDX[
N° ENTRÉE DESCRIPTION d'ouverture-fer-
1 23(1$ 'LVSRVLWLIDYHFFRQWDFWN.O meture
TXLSURYRTXHO
RXYHUWXUH Entrées/Sorties $OLPHQWDWLRQ%DWWHULH0RWHXU0RGXOH
WRWDOHGXSRUWDLO dans le connec- ;)%DWWHULHVGHGpYHUURXLOODJH
teur pOHFWULTXHGHYHUURXLOODJHPRWHXU9HUURXLOOD
2-6 *1' 1pJDWLIG
DOLPHQWDWLRQGHV
DFFHVVRLUHV JH0RWHXU86%
Entrées/Sorties %86($6<23(1$23(1%&/26(6$)(
3 23(1% 'LVSRVLWLIDYHFFRQWDFWN.O.
TXLSURYRTXHO
RXYHUWXUH dans le bornier 67236$)(*1'3KRWRFHOOXOHVG
2XYHUWXUH
'()$8/7
SDUWLHOOHGXSRUWDLO HW)HUPHWXUH9$OLPHQWDWLRQGH
UpVHDX&OLJQRWDQW'pYHUURXLOODJHpOHFWULTXH
CLOSE 'LVSRVLWLIDYHFFRQWDFWN.O
TXLSURYRTXHODIHUPHWXUH YHUURXLOODJHPRWHXU287
GXSRUWDLO
6$)( 'LVSRVLWLIDYHFFRQWDFW N.F.
TXLSURYRTXHO·LQYHUVLRQ
LPPpGLDWHHWFRPSOqWHGX (1) Les types d’utilisation des entrées
SRUWDLO 3 et 4 peuvent être sélectionnés à
4 6723 'LVSRVLWLIDYHFFRQWDFW travers la configuration des paramètres
'()$8/7 N.F.TXLSURYRTXHO
DUUrW correspondants, au 2ème niveau de
GXSRUWDLO programmation (paramètres Ob et SP). Pour
6$)( 'LVSRVLWLIDYHFFRQWDFW N.F. la description exacte du fonctionnement
TXLSURYRTXHO·LQYHUVLRQ de l’automatisme par rapport aux logiques
LPPpGLDWHHWFRPSOqWHGX sélectionnées, se référer aux tableaux qui
SRUWDLO se trouvent à la fin de ce manuel (Par. 10
5 )6:23 'LVSRVLWLIDYHFFRQWDFWN.F. - LOGIQUES DE FONCTIONNEMENT). En ce
TXLSURYRTXHO
LQYHUVLRQ qui concerne les câblages à réaliser en
GXPRXYHPHQWSHQGDQW utilisant ces entrées configurées en tant
O
RXYHUWXUHGXSRUWDLO que SAFE, se référer aux schémas indiqués
7 )6:&/ 'LVSRVLWLIDYHFFRQWDFWN.F. dans les figures Fig.13 et Fig. 14.
TXLSURYRTXHO
LQYHUVLRQGX
PRXYHPHQWSHQGDQWOD (2) L'alimentation en sortie doit déjà être
IHUPHWXUHGXSRUWDLO comprise dans le courant maximum
8 9 3RVLWLIG
DOLPHQWDWLRQGHV disponible pour les accessoires
DFFHVVRLUHV
E721 3 532014 - Rev. D
4 BRANCHEMENTS ÉLECTRIQUES
Les câblages indiqués dans la Fig. 2 se réfèrent aux entrées de la carte avec une configuration par DÉFAUT.
/ SAFE
/ SAFE
3RXUODFRQQH[LRQGHV
SKRWRFHOOXOHVHWGHVGL
VSRVLWLIVGHVpFXULWpYRLU
OHSDUDJUDSKH
230 V ~
115 V ~
=
FRANÇAIS
CONTACT
DEVERROUILLAGE
DE MOTEUR
(Bloque le moteur quand
la poignée de déver-
= rouillage moteur est
actionnée)
)LJ
E721
E721 E721
E721
C720
C 72 C721
C 721
)LJ
$ 3KRWRFHOOXOHVDYHFLQWHUYHQWLRQHQ)(50(785(
% 3KRWRFHOOXOHVDYHFLQWHUYHQWLRQHQ289(5785(
& 3KRWRFHOOXOHVDYHFLQWHUYHQWLRQHQ289(5785(
HWHQ)(50(785(
)LJ
FRANÇAIS
2)) 21 2)) 21 Max 2 paires
$YDQWGHEUDQFKHUOHVSKRWRFHOOXOHVLOFRQYLHQWGHFKRLVLU
OHW\SHGHIRQFWLRQQHPHQW)LJVXUODEDVHGHOD]RQH 21 21 21 21 ,038/6,21
23(1
GHPRXYHPHQWTX
HOOHVGRLYHQWSURWpJHUHWGHSRVLWLRQQHU
OHV',36:,7&+(VVXUO
pPHWWHXUDLQVLTXHVXUOHUpFHSWHXU 4.1.2. MÉMORISATION DES ACCESSOIRES BUS-2EASY
YRLU)LJFRQIRUPpPHQWDX7DE WRXWPRPHQWRQSHXWDMRXWHUGHVSKRWRFHOOXOHVHWGHV
)LJ
DFFHVVRLUHV %86($6< j O·LQVWDOODWLRQ VLPSOHPHQW HQ
SURFpGDQWFRPPHVXLW
DL1 $OLJQH ,QVWDOOHUHWSURJUDPPHUOHVDFFHVVRLUHVDYHFO
DGUHVVH
RX TX PHQW VRXKDLWpHYRLUSDU
DL2
DL2 (WDW%86 &RXSHUO
DOLPHQWDWLRQjODFDUWH
DL1 ($6<$OLPHQ %UDQFKHUOHVGHX[FkEOHVGHVDFFHVVRLUHV%86($6<
ON
DS1
ON
DS1 WDWLRQ DXERUQLHUURXJH-SRODULWpLQGLIIpUHQWH
DS1 ',36:,7 $OLPHQWHUODFDUWH
1 2 3 4 1 2 3 4
DL2
BUS BUS BUS BUS
&+(6 SRXU OD $SSX\HUUDSLGHPHQWXQHIRLVVXUOHSRXVVRLU6(7836:
SRXUHIIHFWXHUO
LQVFULSWLRQGHVDFFHVVRLUHV9pULILHUOH
RX - TX
SURJUDPPD IRQFWLRQQHPHQWGHVGLVSRVLWLIVj%86($6<LQVWDOOpV
WLRQ
/DFDUWHDPpPRULVpOHVDFFHVVRLUHV%86($6<
6XLYUHOHVLQGLFDWLRQVGXWDEOHDXVXLYDQWSRXUFRQWU{OHUOH
ERQpWDWGXEUDQFKHPHQW%86($6<
Exécuter la même procédure sur une centrale
MASTER également pour la saisie d’une
centrale SLAVE connectée au BUS-2EASY par
4.1.1. ADRESSAGE DES PHOTOCELLULES BUS-2EASY l’intermédiaire d’une connexion POLARISÉE.
Il est important de donner la même adresse Tab. 2 - Description de la led BUS-2EASY
à l'émetteur et au récepteur.
$FWLYLWp QRUPDOH OHG DOOXPpH PrPH
Il faut s'assurer qu'il n'y ait pas deux ou Allumé fixe HQ O
DEVHQFH GH SKRWRFHOOXOHV $XFXQH
plusieurs paires de photocellules avec la SKRWRFHOOXOHLQVFULWHHQJDJpH
même adresse.
Clignotant $XPRLQVXQHSKRWRFHOOXOHLQVFULWHHQJD
Si l'on n'utilise aucun accessoire BUS-2EASY, lent JpHRXQRQDOLJQpH
laisser libre le connecteur BUS-2EASY (J12 -
Fig. 1). Éteint
(clignotement
/LJQH%86($6<HQFRXUWFLUFXLW
toutes les 2,5
sec.)
/LJQH%86($6<GpVDFWLYpHHOOHQHIRXUQLW
SDVG·DOLPHQWDWLRQ
Éteint
)RQFWLRQQHPHQWjEDWWHULH
&HQWUDOHSURJUDPPpHFRPPH6/$9(
OUT
Autres sécurités
OUT
OUT
)LJ
%UDQFKHPHQWSDLUHGHSKRWRFHOOXOHVHQIHUPHWXUH
DYHFVpFXULWp)$,/6$)(HW6723désactivée
%UDQFKHPHQWGHGHX[SDLUHVGHSKRWRFHOOXOHVHQIHUPHWXUH
FRANÇAIS
Autres sécurités
)LJ
%UDQFKHPHQWG·XQHSDLUHGHSKRWRFHOOXOHVHQRXYHUWXUH
Autres sécurités
)LJ )LJ
)LJ
FRANÇAIS
)LJ
Autres sécurités
Autres sécurités
OPEN A OPEN A
GND GND
OPEN B / CLOSE - OUT SAFE / OPEN B / CLOSE
- OUT SAFE / STOP STOP
FSW OP FSW OP
GND GND
FSW CL FSW CL
+24V +24V )LJ
En cas d’activation de la sécurité Fail Safe (paramètre configurable au 2ème niveau de programmation),
le négatif à utiliser pour la gestion de l’entrée SAFE devra être - (voir Fig. 14).
Autres sécurités
Autres sécurités OPEN A
GND OPEN A
OPEN B / CLOSE GND
SAFE / STOP - SAFE / OPEN B / CLOSE
- FSW OP STOP
GND FSW OP
FSW CL GND
+24V FSW CL
+24V )LJ
Si l’on utilise les dispositifs avec un contact N.F. (Autres sécurités), ponter l’entrée SAFE au négatif -OUT
avec FAIL SAFE activé ou à GND avec FAIL SAFE désactivé.
E721 7 532014 - Rev. D
5. PROGRAMMATION La modification des paramètres de
3RXUSURJUDPPHUOHIRQFWLRQQHPHQWGHO
DXWRPDWLVPHLOHVW programmation est immédiatement efficace,
tandis que la mémorisation définitive ne se
QpFHVVDLUHG
DFFpGHUjODPRGDOLWp©352*5$00$7,21ª
produit qu’à la sortie de la programmation et
/DSURJUDPPDWLRQVHGLYLVHHQGHX[SDUWLHVHU1,9($8qPH au retour de l’affichage de l’état des entrées. Si
1,9($8 l’on met l’armoire hors tension avant le retour
Normalement, l'état de l'automatisme est de l’affichage de l’état des entrées, toutes les
affiché à l'écran. En appuyant sur le poussoir variations effectuées seront perdues.
F, ou bien en appuyant simultanément sur Il est possible de revenir à l'affichage de
F et +, on accède respectivement à la l'état des entrées et de mémoriser tous les
programmation de 1er ou de 2ème niveau. paramètres modifiés jusqu'alors, depuis
L’afficheur est éteint durant le fonctionnement n'importe quel point de la programmation de
à batterie. Appuyer brièvement sur la touche
1er et 2ème niveau, en appuyant simultanément
+ pour afficher l’état de l’automatisme.
sur les touches F et -.
Afin de rétablir les réglages par défaut,
A l'allumage de la carte sur l'écran LCD1,
il suffit de recharger la valeur par défaut
la version logicielle de la carte apparaîtra
souhaitée pendant le premier passage de
pendant quelques secondes à deux chiffres
la programmation de 1er niveau.
séparés par le point décimal.
5.1 PROGRAMMATION DE 1er NIVEAU
3RXUDFFpGHUjODSURJUDPPDWLRQGHHUQLYHDXLOIDXWDSSX\HUVXUOHSRXVVRLUF
(QDSSX\DQWVXUODWRXFKHFHWHQODPDLQWHQDQWHQIRQFpHO·DIILFKHXULQGLTXHOHQRPGHODIRQFWLRQ
(QUHOkFKDQWOHSRXVVRLUO
pFUDQDIILFKHODYDOHXUGHODIRQFWLRQTXLSHXWrWUHPRGLILpHDYHFOHVWRXFKHVHW
(QDSSX\DQWjQRXYHDXVXUFHWHQOHPDLQWHQDQWHQIRQFpO
pFUDQPRQWUHOHQRPGHODIRQFWLRQVXLYDQWHHWF
$UULYpVjODGHUQLqUHIRQFWLRQODSUHVVLRQGXSRXVVRLUFSURYRTXHODVRUWLHGHODSURJUDPPDWLRQHWODVDXYHJDUGH
FRANÇAIS
GHVSDUDPqWUHV/
pFUDQUHFRPPHQFHG
DIILFKHUO
pWDWGHO
DXWRPDWLVPH
FRANÇAIS
VITESSE DE FERMETURE :
Sc 5qJOHVXUQLYHDX[ODYLWHVVHGHIHUPHWXUHGXPRWHXU
08
0 1 YLWHVVHPLQLPDOH
1 0 YLWHVVHPD[LPDOH
En modifiant la valeur de la vitesse, il est conseillé d'effectuer un nouveau
SETUP (voir par. 7.3)
RALENTISSEMENT EN OUVERTURE :
ro ,OUqJOHO
HVSDFHGHUDOHQWLVVHPHQWHQSRXUFHQWDJHGHODFRXUVHWRWDOHGXSRUWDLO5pJODEOH
20
jSDUWLUGH5 DYHFYLWHVVH10 DYHFYLWHVVHHQWUHHW15 DYHFYLWHVVH!j99
SDUSDVGH
5-10-15 UDOHQWLVVHPHQWPLQLPXP
99 UDOHQWLVVHPHQWPD[LPXP
RALENTISSEMENT EN FERMETURE :
rc ,OUqJOHO
HVSDFHGHUDOHQWLVVHPHQWHQSRXUFHQWDJHGHODFRXUVHWRWDOHGXSRUWDLO5pJODEOH
20
jSDUWLUGH5 DYHFYLWHVVH10 DYHFYLWHVVHHQWUHHW15 DYHFYLWHVVH!j99
SDUSDVGH
5-10-15 UDOHQWLVVHPHQWPLQLPXP
99 UDOHQWLVVHPHQWPD[LPXP
VITESSE EN RALENTISSEMENT :
Sr 5qJOHODYLWHVVHGXSRUWDLOSHQGDQWOHUDOHQWLVVHPHQW
0
0 YLWHVVH%$66(
1 YLWHVVH(/(9((
ÉTAT DE L'AUTOMATISME :
St 6RUWLHGHODSURJUDPPDWLRQPpPRULVDWLRQGHVGRQQpHVHWUHWRXUjO
DIILFKDJHGHO
pWDWGHO
DXWRPD
WLVPH
00 )(50e 07 )$,/6$)(HQFRXUV
01 289(57 08 YpULILFDWLRQGHVGLVSRVLWLIV%86($6<HQ
02 $UUrWpSXLV©2895(ª FRXUV
03 $UUrWpSXLV©)(50(ª 09 3UpFOLJQRWHPHQWHQVXLWH©2895(ª
04 (Q©3$86(ª 10 3UpFOLJQRWHPHQWHQVXLWH©)(50(ª
05 (QSKDVHG
RXYHUWXUH 11 289(57HQ2XYHUWXUH3DUWLHOOH
06 (QSKDVHGHIHUPHWXUH 12 (Q3$86(2XYHUWXUH3DUWLHOOH
Par
Écran Fonction
défaut 1
FORCE MAXIMALE AU DÉMARRAGE :
bo /HPRWHXUWUDYDLOOHjODIRUFHPD[LPDOHHQLJQRUDQWOHQLYHDXGHIRUFHVpOHFWLRQQpSHQGDQW
no
OHGpPDUUDJHGHODPDQXWHQWLRQ
Y DFWLI
no H[FOXV
PRÉ-CLIGNOTEMENT :
PF 3HUPHWGHVpOHFWLRQQHUW\SHVGHSUpFOLJQRWHPHQWG
XQHGXUpHpJDOHjVHFRQGHV
no
no DXFXQSUpFOLJQRWHPHQW
OC SUpFOLJQRWHPHQWDYDQWFKDTXHPDQXWHQWLRQ
FRANÇAIS
CL SUpFOLJQRWHPHQWDYDQWXQHPDQXWHQWLRQGHIHUPHWXUH
OP SUpFOLJQRWHPHQWDYDQWXQHPDQXWHQWLRQHQRXYHUWXUH
PA SUpFOLJQRWHPHQWXQLTXHPHQWjODILQG
XQHSDXVH
TEMPS DE PRÉ-CLIGNOTEMENT (visible uniquement si un pré-clignotement a été sélectionné
tP dans le menu précédent) : 03
5qJOHOHWHPSVGHSUpFOLJQRWHPHQWGH 1 j10 VHFSDUSDVG
VHFRQGH
01 SUpFOLJQRWHPHQWPLQLPXP
10 SUpFOLJQRWHPHQWPD[LPXP
PHOTOCELLULES EN FERMETURE :
Ph $FWLYHUODIRQFWLRQVLO
RQVRXKDLWHTXHOHVSKRWRFHOOXOHVGHIHUPHWXUHEORTXHQWOHPRXYH
no
PHQWHWO
LQYHUVHQWORUVGHODGpVDFWLYDWLRQ1RUPDOHPHQWDYHFFHWWHIRQFWLRQGpVDFWLYpH
O
LQWHUYHQWLRQGHVSKRWRFHOOXOHVHQIHUPHWXUHGpWHUPLQHXQHLQYHUVLRQLPPpGLDWHGXSRUWDLO
Y LQYHUVLRQORUVGHODGpVDFWLYDWLRQ
n o LQYHUVLRQLPPpGLDWHHQRXYHUWXUH
Paramètre non affiché en modalité SLAVE
PHOTOCELLULES EN OUVERTURE :
oP $FWLYHU OD IRQFWLRQ VL O
RQ VRXKDLWH TXH OHV SKRWRFHOOXOHV G
RXYHUWXUH EORTXHQW OH PRXYH
no
PHQWHWO
LQYHUVHQWORUVGHODGpVDFWLYDWLRQ1RUPDOHPHQWDYHFFHWWHIRQFWLRQGpVDFWLYpH
O
LQWHUYHQWLRQGHVSKRWRFHOOXOHVHQRXYHUWXUHGpWHUPLQHODUHSULVHGXPRXYHPHQWORUVGH
OHXUGpVDFWLYDWLRQ
Y LQYHUVLRQLPPpGLDWHHQIHUPHWXUH
n o UHSULVHGXPRXYHPHQWORUVGHODGpVDFWLYDWLRQ
Paramètre non affiché en modalité SLAVE
FONCTION ADMAP :
Ad 3HUPHWG
DFWLYHUOHIRQFWLRQQHPHQWVHORQOHVQRUPHVIUDQoDLVHV1)3
no
Y DFWLI
no GpVDFWLYp
ENCODER :
EC /
HQFRGHXU©YLUWXHOªSUpVHQWVXUODFDUWHIRQFWLRQQHFRPPHXQGLVSRVLWLIDQWLpFUDVHPHQW 02
HWJqUHOHVSRLQWVGHGpEXWGHUDOHQWLVVHPHQWHWG
RXYHUWXUHSDUWLHOOH
6LOHSRUWDLOSHQGDQWODSKDVHG
RXYHUWXUHRXGHIHUPHWXUHKHXUWHXQREVWDFOHO
HQFRGHU
©YLUWXHOªSURYRTXHO
LQYHUVLRQGXPRXYHPHQW/HVHFRQGREVWDFOHGpWHFWpGDQVODPrPH
GLUHFWLRQSURYRTXHO
DUUrWGXPRWHXU'DQVOHVGHX[FDVXQHDODUPHHVWVLJQDOpHYRLUSDU
DODUPHV
,OIDXWUpJOHUODVHQVLELOLWpGHO
HQFRGHU©YLUWXHOªHQPRGLILDQWOHWHPSVSHQGDQWOHTXHOOD
FDUWHDWWHQGDYDQWGHFRPPDQGHUO
LQYHUVLRQGXPRXYHPHQWG
XQPLQLPXPGH 0 VHFj
XQPD[LPXPGH10 VHFSDUSKDVHG
XQHVHFRQGH
00 VHQVLELOLWpPD[LPDOH
10 VHQVLELOLWpPLQLPDOH
E721 10 532014 - Rev. D
Par
Écran Fonction
défaut 1
OUVERTURE PARTIELLE :
PO ,OHVWSRVVLEOHGHUpJOHUO
DPSOHXUGHO
RXYHUWXUHSDUWLHOOHGXEDWWDQWHQSRXUFHQWDJHGHOD 50
FRXUVHWRWDOHGXSRUWDLO
5pJODEOHGHjSDUSDVGH
00 DXFXQHRXYHUWXUHSDUWLHOOH
01 RXYHUWXUHSDUWLHOOHPLQLPDOH
99 RXYHUWXUHSDUWLHOOHPD[LPDOH
DURÉE DE FONCTIONNEMENT (time-out) :
t ,OFRQYLHQWG
pWDEOLUXQHYDOHXUVXSpULHXUHDXWHPSVQpFHVVDLUHDXSRUWDLOSRXUV
RXYULUHWVH 2.0
IHUPHUWRWDOHPHQW
5pJODEOHGH0 j59 VHFSDUSDVG
VHFRQGH(QVXLWHO
DIILFKDJHFKDQJHHQPLQXWHVHW
GL[LqPHVGHVHFRQGHVpSDUpVSDUXQSRLQWHWOHWHPSVHVWUpJOpSDUSDVGHVHFRQGHV
MXVTX
jODYDOHXUPD[LPDOHGH9,5 PLQXWHV
(;VLO
pFUDQLQGLTXH2,5 OHWHPSVGHSDXVHFRUUHVSRQGjPLQHWVHF
En cas d’installation en configuration MASTER/SLAVE, sélectionner un TEMPS DE
FONCTIONNEMENT sur la centrale MASTER qui tienne compte des temps
d’actionnement des deux vantaux.
OUT 1 :
o1 3HUPHWGHUpJOHUODVRUWLH287RSHQFROOHFWRU12DFWLYHGDQVO
XQHGHVIRQFWLRQVVXLYDQWHV 00
00 7RXMRXUVDFWLYHIRXUQLWXQHWHQVLRQ9 DYHFDEVRUSWLRQPD[LPDOHGHP$
01 )$,/6$)(9pULILHOHIRQFWLRQQHPHQWFRUUHFWGHVSKRWRFHOOXOHVWUDGLWLRQQHOOHVUDFFRUGpHV
02 /$03(7e02,1pWHLQWHGHIHUPpHDOOXPpHHQRXYHUWXUHHWRXYHUWHSDXVHFOLJQRWDQWHQIHUPHWXUH
FRANÇAIS
03 /80,(5('(&28572,6,(YRLUIRQFWLRQVXLYDQWH
04 $/$50(GHIRQFWLRQQHPHQWj%$77(5,(
05 SRUWDLO289(57RXHQ3$86(
06 SRUWDLO)(50(
07 SRUWDLOHQ0289(0(17
08 SRUWDLOHQ289(5785(
09 SRUWDLOHQ)(50(785(
1 0 VpFXULWp$&7,9(
1 1 VRUWLHWHPSRULVpHSRXYDQWrWUHDFWLYpHGHSXLVOHVHFRQGFDQDOUDGLRYRLUIRQFWLRQVXLYDQWH
1 2 VRUWLHSRXYDQWrWUHDFWLYpHGHSXLVOHVHFRQGFDQDOUDGLRIRQFWLRQSDVjSDV
t1 TEMPORISATION OUT 1 (visible uniquement si le poste 03 ou 11 a été sélectionné à l'étape
précédente) :
02
3HUPHWGHUpJOHUODWHPSRULVDWLRQGHODVRUWLH287VLXQHIRQFWLRQDpWpVpOHFWLRQQpHjWHPSV
FRPPHSDUH[03RX11 GH1 j99 PLQXWHVSDUpWDSHVG
PLQXWH
OPEN B / CLOSE / SÉCURITÉ BORD:
Ob ,O HVW SRVVLEOH GH VpOHFWLRQQHU O
XWLOLVDWLRQ GH O
HQWUpH 23(1 % FRPPH RXYHUWXUH SDUWLHOOH 00
FRPPDQGHGH&/26(RX6e&85,7e%25'
00 23(1%
01 &/26(
02 6e&85,7e%25'FRQWDFW1)
Si l'on sélectionne une logique de fonctionnement qui prévoit l'utilisation de la
commande de CLOSE (logique b, bC, C), cette fonction sera préréglée sur 01
et il ne sera pas possible de la modifier.
STOP / SÉCURITÉ BORD :
SP ,OHVWSRVVLEOHGHVpOHFWLRQQHUO
XWLOLVDWLRQGHO
HQWUpH6723FRPPH6723RX6e&85,7e%25' 00
00 6723
01 6e&85,7e%25'FRQWDFW1)
INVERSION PARTIELLE :
IP 2QSHXWVpOHFWLRQQHUOHW\SHG·LQYHUVLRQFRPSOqWHRXSDUWLHOOHVXLWHjXQREVWDFOHRXjXQH no
LQWHUYHQWLRQGXERUGVHQVLEOH
Y $FWLYDWLRQGHO·LQYHUVLRQSDUWLHOOH(QSUpVHQFHG·XQREVWDFOHRXVXLWHjO·DFWLYDWLRQ
GX ERUG VHQVLEOH OH PRXYHPHQW GX YDQWDLO HVW LQYHUVp SHQGDQW HQYLURQ
VHFRQGHVSXLVV·DUUrWH
no 'pVDFWLYDWLRQGHO·LQYHUVLRQSDUWLHOOH(QSUpVHQFHG·XQREVWDFOHRXVXLWHjO·DFWLYDWLRQ
GXERUGVHQVLEOHOHPRXYHPHQWGXYDQWDLOHVWFRPSOqWHPHQWLQYHUVpFHOXLFLVH
SRVLWLRQQHHQSRVLWLRQRXYHUWHRXIHUPpH
BLOCAGE MOTEUR :
Lc ,OHVWSRVVLEOHGHVpOHFWLRQQHUO·XWLOLVDWLRQGXEORFDJHGHPRWHXUSHQGDQWOHIRQFWLRQQHPHQW Y
DYHFODEDWWHULH
Y OHEORFDJHGHPRWHXUFRQWLQXHGHIRQFWLRQQHUUpJXOLqUHPHQWPrPHSHQGDQW
OHIRQFWLRQQHPHQWDYHFODEDWWHULH
no TXDQGRQSDVVHDXIRQFWLRQQHPHQWSDUEDWWHULHOHEORFDJHGHPRWHXU
UHVWHWRXMRXUVRXYHUW
E721 11 532014 - Rev. D
Par
Ecran Fonction
défaut 1
DEMANDE D'ASSISTANCE - COMPTEUR DE CYCLES (combinée aux deux fonctions suivantes) :
AS Y ORUVTXHO
RQDWWHLQWOHQRPEUHGHF\FOHVUpJODEOHDYHFOHVIRQFWLRQVVXLYDQWHVnc HW no
nd HIIHFWXHXQSUpFOLJQRWHPHQWGHVHFHQSOXVGHFHOXLpYHQWXHOOHPHQWGpMj
pWDEOLDYHFODIRQFWLRQPF DYDQWWRXWHPDQXWHQWLRQ
no OHVIRQFWLRQVVXLYDQWHVnc HWnd LQGLTXHQWFRPELHQGHF\FOHVO
LQVWDOODWLRQDHIIHFWXpV
MXVTX
jXQPD[LPXPSRXYDQWrWUHDIILFKpGH99 990
Si le nombre de cycles effectué est supérieur à 99 990 les deux fonctions
suivantes nc et nd afficheront respectivement 99 et 99.
&HWWHIRQFWLRQSHXWrWUHXWLOHSRXUpWDEOLUGHVLQWHUYHQWLRQVG
HQWUHWLHQSURJUDPPpRXSRXU
YpULILHUOHVF\FOHVGHWUDYDLOHIIHFWXpV
PROGRAMMATION DES CYCLES (MILLIERS) :
nc 6L AS Y O
pFUDQ LQGLTXH OH QRPEUH GH PLOOLHUV GH F\FOHV DSUqV OHTXHO RQ GHPDQGH
00
O
DVVLVWDQFHUpJODEOHGH0 j99
6LAS no O
pFUDQLQGLTXHOHQRPEUHGHPLOOLHUVGHF\FOHVHIIHFWXpV/DYDOHXUDIILFKpH
HVWPLVHjMRXUDYHFODVXFFHVVLRQGHVF\FOHVHQLQWHUDJLVVDQWDYHFODYDOHXUGHnd
Si AS = no en appuyant sur les touches + et - pendant 5 sec., le compteur
de cycles est mis à zéro.
PROGRAMMATION DES CYCLES (DIZAINES) :
nd 6L AS Y O
pFUDQLQGLTXHOHQRPEUHGHGL]DLQHVGHF\FOHVDSUqVOHTXHOO
DVVLVWDQFH HVW
00
GHPDQGpHUpJODEOHGH0 j99
6LAS no O
pFUDQLQGLTXHOHQRPEUHGHGL]DLQHVGHF\FOHVHIIHFWXpV/DYDOHXUDIILFKpH
VHPHWjMRXUDYHFODVXFFHVVLRQGHVF\FOHVHQLQWHUDJLVVDQWDYHFODYDOHXUGHnc
FRANÇAIS
6.2. MÉMORISATION DES RADIOCOMMANDES SLH Utiliser les télécommandes LC/RC uniquement
avec un module récepteur à 433 MHz.
Il est possible de mémoriser au maximum 0DLQWHQLUOHSRXVVRLU+6:RX-6:HQIRQFpSXLV
256 codes divisés entre OPEN A et OPEN B/
DSSX\HU VXU OH SRXVVRLU 6(783 6: SRXU PpPRULVHU
CLOSE.
UHVSHFWLYHPHQWO
RXYHUWXUHWRWDOH23(1$RXO
RXYHUWXUH
6XU OD UDGLRFRPPDQGH 6/+ DSSX\HU HW PDLQWHQLU SDUWLHOOH23(1%&/26(/DOHGFRUUHVSRQGDQWHFRP
HQIRQFpVOHVSRXVVRLUV3HW3VLPXOWDQpPHQW PHQFHUDjFOLJQRWHUOHQWHPHQWSHQGDQWVHF
/D OHG GH OD UDGLRFRPPDQGH FRPPHQFHUD j FOL 5HOkFKHUOHSRXVVRLU
JQRWHU
'DQVFHGpODLGHVHFRQGHVDSSX\HUVXUOHSRXVVRLU
5HOkFKHUOHVGHX[SRXVVRLUV
VRXKDLWpVXUODWpOpFRPPDQGH/&5&
0DLQWHQLUOHSRXVVRLU+6:RX-6:HQIRQFpSXLV
DSSX\HUVXUOHSRXVVRLU6(7836:SRXUPpPRULVHU /DOHGV
DOOXPHUDGHIDoRQIL[HSHQGDQWVHFRQGH
UHVSHFWLYHPHQWO
RXYHUWXUHWRWDOH23(1$RXO
RXYHU HQLQGLTXDQWODPpPRULVDWLRQHIIHFWLYHSRXUUHFRP
WXUHSDUWLHOOH23(1%&/26(/DOHGFRUUHVSRQGDQWH PHQFHUHQVXLWHjFOLJQRWHUSHQGDQWDXWUHVVHFRQGHV
FRPPHQFHUDjFOLJQRWHUOHQWHPHQWSHQGDQWVHF SHQGDQW OHVTXHOOHV LO HVW SRVVLEOH GH PpPRULVHU XQH
5HOkFKHUOHVGHX[SRXVVRLUV DXWUHUDGLRFRPPDQGH
3HQGDQW FHV VHF WDQGLV TXH OD OHG GH OD UDGLR 8QHIRLVSDVVpHVOHVVHFRQGHVODOHGV
pWHLQWHQLQGL
FRPPDQGHFOLJQRWHHQFRUHHQIRQFHUHWPDLQWHQLU TXDQWODILQGHODSURFpGXUH
HQIRQFpOHSRXVVRLUVRXKDLWpVXUODUDGLRFRPPDQGH
6.3.1 MÉMORISATION À DISTANCE DE
ODOHGGHODUDGLRFRPPDQGHV
DOOXPHUDGHPDQLqUH
FRANÇAIS
IL[H RADIOCOMANDES LC/RC
/DOHGVXUODFDUWHV
DOOXPHUDIL[HSHQGDQWVHFRQGHV $YHF GHV UDGLRFRPPDQGHV /&5& RQ SHXW PpPRULVHU
SRXUV
pWHLQGUHHQVXLWHHQLQGLTXDQWODPpPRULVDWLRQ G
DXWUHV UDGLRFRPPDQGHV j GLVWDQFH F
HVWjGLUH VDQV
HIIHFWLYH LQWHUYHQLUGLUHFWHPHQWVXUODFDUWHHQXWLOLVDQWXQHUDGLR
5HOkFKHUOHSRXVVRLUGHODUDGLRFRPPDQGH FRPPDQGHSUpFpGHPPHQWPpPRULVpH
$SSX\HUGHX[IRLVVXFFHVVLYHPHQWHWUDSLGHPHQWVXU 6HSURFXUHUXQHUDGLRFRPPDQGHGpMjPpPRULVpHVXU
OHSRXVVRLUGHODUDGLRFRPPDQGHPpPRULVpH O
XQGHVGHX[FDQDX[23(1$RX23(1%&/26(
L’automatisme effectuera une ouverture. (QIRQFHUHWPDLQWHQLUHQIRQFpVOHVSRXVVRLUV3HW3
S'assurer que l'automatisme ne présente VLPXOWDQpPHQWMXVTX
jFHTXHOHVGHX[OHGVFOLJQRWHQW
aucun obstacle créé par des personnes OHQWHPHQWSHQGDQWVHFRQGHV
ou des biens. 'DQVXQGpODLGHVHFDSSX\HUVXUOHSRXVVRLUSUp
3RXU DFWLYHU G
DXWUHV UDGLRFRPPDQGHV D\DQW OH PrPH FpGHPPHQWPpPRULVpGHODUDGLRFRPPDQGHSRXU
FRGHG
LQVWDOODWLRQLOHVWQpFHVVDLUHGHWUDQVIpUHUOHFRGH DFWLYHUODSKDVHG
DSSUHQWLVVDJHVXUOHFDQDOFKRLVL
GHO
LQVWDOODWLRQGXSRXVVRLUGHODUDGLRFRPPDQGHPpPR /DOHGVXUODFDUWHFRUUHVSRQGDQWDXFDQDOHQDSSUHQ
ULVpHDXSRXVVRLUFRUUHVSRQGDQWGHVUDGLRFRPPDQGHVj WLVVDJHFOLJQRWHSHQGDQWVHFSHQGDQWOHVTXHOOHVLOIDXW
DMRXWHUHQVXLYDQWODSURFpGXUHVXLYDQWH WUDQVPHWWUHOHFRGHG
XQHDXWUHUDGLRFRPPDQGH
D VXUODUDGLRFRPPDQGHPpPRULVpHDSSX\HUHW /DOHGV
DOOXPHUDGHIDoRQIL[HSHQGDQWVHFRQGHHQ
PDLQWHQLUHQIRQFpVOHVSRXVVRLUV3HW3VLPXO LQGLTXDQWODPpPRULVDWLRQHIIHFWLYHHWUHFRPPHQFHUD
WDQpPHQW HQVXLWHjFOLJQRWHUSHQGDQWDXWUHVVHFRQGHVSHQ
E /D OHG GH OD UDGLRFRPPDQGH FRPPHQFHUD j GDQWOHVTXHOOHVLOHVWSRVVLEOHGHPpPRULVHUXQHDXWUH
FOLJQRWHU UDGLRFRPPDQGH
F 5HOkFKHUOHVGHX[SRXVVRLUV
G $SSX\HUVXUOHSRXVVRLUPpPRULVpHWOHPDLQWHQLU
6.4. PROCÉDURE D'EFFACEMENT DES RADIOCOMMANDES
HQIRQFpODOHGGHODUDGLRFRPPDQGHV
DOOXPHUD 3RXUHIIDFHUTOUSOHVFRGHVGHVUDGLRFRPPDQGHVLQVp
GHPDQLqUHIL[H UpHVLOVXIILWGHPDLQWHQLUOHVGHX[SRXVVRLUV+6:HW-
H $SSURFKHUOHVUDGLRFRPPDQGHVDSSX\HUVXUOH 6:HQIRQFpVSXLVG
DSSX\HUSHQGDQWXQHVHFRQGHVXU
SRXVVRLUFRUUHVSRQGDQWGHODUDGLRFRPPDQGHj OHSRXVVRLU6(7836:HWGHPDLQWHQLUHQIRQFpVOHVGHX[
DMRXWHUHWOHPDLQWHQLUHQIRQFpHQQHOHUHOkFKDQW SUHPLHUVSRXVVRLUVSHQGDQWVHF
TX
DSUqVOHGRXEOHFOLJQRWHPHQWGHODOHGGHOD /HVOHGV5$',2HW5$',2FOLJQRWHURQWUDSLGHPHQW
UDGLRFRPPDQGH TXL LQGLTXH OD PpPRULVDWLRQ SHQGDQWVHFRQGHV
HIIHFWLYH /HVOHGVV
DOOXPHURQWIL[HPHQWSHQGDQWVHFRQGHV
I $SSX\HU GHX[ IRLV VXFFHVVLYHPHQW HW UDSLGH SRXUV
pWHLQGUHHQVXLWHHIIDFHPHQWHIIHFWXp
PHQW VXU OH SRXVVRLU GH OD UDGLRFRPPDQGH
5HOkFKHUOHVGHX[SRXVVRLUV
PpPRULVpH
Cette opération N'est PAS réversible. Tous les
L’automatisme effectuera une ouverture.
codes des radiocommandes mémorisées se-
Il faut s'assurer que l'automatisme ne pré-
ront effacés, tant comme OPEN A que comme
sente aucun obstacle créé par des personnes
OPEN B/CLOSE.
ou des biens.
< (1) F
BUS 2EASY
< (2)
< OPEN A -
< GND
< OPEN B / CLOSE < SAFE
+
R
A
C
1
RADIO XF
R
2
IO
E
FC
FC
IO
O
< STOP / SAFE
W
R
D
O
R
A
P
R
< FSW OP
R
SETUP
< GND
< FSW CL
< +24
USB
FRANÇAIS
BATTERY
RELEASE
Y
R
)
R
F
OUT
-L
E
S
S
E IN
TO
R M
K
K
K
T
-N
N
T EC
C
T
T RI
C
C
(P A
- +
A
LO
LA
LO
LO
M
R
P
M
B
<
<
<
<
<
<
<
<
<
)LJ
A
C
R O1
2
FC
FC
IO
I
)DLUHFRXOLVVHUVXUODFUpPDLOOqUHO
DLPDQWDYHFOHRONDGDQVODGLUHFWLRQGXPRWHXU'qV
R
A
E
R
TXHODOHGUHODWLYHjODILQGHFRXUVH)&$SUpVHQWHVXUODFDUWHV
pWHLQWODIL[HUDYHFOHV
YLVDGKRF
0HWWUHPDQXHOOHPHQWOHSRUWDLOHQSRVLWLRQGH fermetureHQODLVVDQWPPGHO
DUUrW
PpFDQLTXHGHILQGHFRXUVH
)DLUHFRXOLVVHUVXUODFUpPDLOOqUHO
DLPDQWDYHFOHCARRÉGDQVODGLUHFWLRQGXPRWHXU'qV
TXHODOHGUHODWLYHjODILQGHFRXUVH)&&SUpVHQWHVXUODFDUWHV
pWHLQWODIL[HUDYHFOHV
YLVDGKRF
A
C
R O1
2
FC
FC
IO
&RQWU{OHUTX
jODILQGHODPDQRHXYUHWDQWHQRXYHUWXUHTX
HQIHUPHWXUHODOHGGHODILQ
I
D
R
A
A
GHFRXUVHUHVSHFWLYHV
pWHLJQHFRUUHFWHPHQWHWOHFDVpFKpDQWDSSRUWHUOHVPRGLILFDWLRQV
E
R
FRQYHQDEOHVjODSRVLWLRQGHVDLPDQWVGHILQGHFRXUVH
Pour éviter des dommages de l'opérateur et/ou des interruptions du
FRANÇAIS
fonctionnement de l'automatisme, il est nécessaire de laisser environ 40 mm
par rapport aux butées mécaniques de fin de course.
Pour un bon
fonctionnement de
l'opérateur, l'aimant
représentant le
ROND doit être
utilisé comme fin de
course d'OUVERTURE
et l'aimant avec le
CARRÉ doit être utilisé
comme fin de course
de FERMETURE
(VOIR FIG.17)
En cas d’installation
en configuration
MA STER/SL AVE, les
aimants de fin de
course devront être
installés d’après la
Fig. 18.
)LJ
MASTER/SLAVE
)LJ
Éviter tout type de connexion et de câblage sur le bornier J13 de la centrale SLAVE
La connexion BUS entre les deux cartes devra être POLARISÉE en respectant la séquence des deux
pôles du bornier J12 (POLE (1) - POLE (2)) - (voir Fig. 19).
Lorsqu’on configure une centrale comme SLAVE, on force les valeurs de certains paramètres de
programmation qui ne sont plus affichés dans le menu (LO-PA-Pb-Ph-Op). Lorsqu’on ramène
la carte en modalité MASTER, ces valeurs qui avaient été forcées sont maintenues à l’intérieur
de la programmation.
7.4.1 CÂBLAGES MASTER-SLAVE
FRANÇAIS
(1) (1)
BUS 2 EASY BUS 2 EASY
(2) (2)
1HUpDOLVHU
DXFXQHFRQQH[LRQ
jFHERUQLHU
La demande de SETUP par l’intermédiaire du clignotement du sigle S0 sur l’afficheur peut s’afficher
sur la centrale MASTER et sur la centrale SLAVE. Dans le second cas, l’erreur 91 s’affiche sur la
centrale MASTER. Quoi qu’il en soit, la procédure de SETUP ne pourra être exécutée que sur la
centrale MASTER.
3RXUH[pFXWHUOH6(783VXUXQHLQVWDOODWLRQ0$67(56/$9(SURFpGHUFRPPHVXLW
FRANÇAIS
HVW FHOOH G
RXYHUWXUH DYHF OH ROND O·DSSDUHLOODJH 4 0 'HPDQGHG
DVVLVWDQFH
PpPRULVHUD FH SRLQW FRPPH EXWpH HQ ouverture 5pWDEOLVVHPHQWIRUFpGHODSURJUDPPDWLRQ
'DQVFHWWHSKDVHS 1 FOLJQRWHjO
pFUDQ 4 6 SDUGpIDXW
/H SRUWDLO FRPPHQFH DXWRPDWLTXHPHQW OH 9.2 ERREURS
PRXYHPHQW UDOHQWL GDQV OD GLUHFWLRQ RSSRVpH HQ Quand une ERREUR se présente, la led
V
DUUrWDQWORUVTX
LODWWHLQWODILQGHFRXUVH6LODILQGH DL20 s'allume fixement et en appuyant
FRXUVHDWWHLQWHVHUDFHOOHGHO
RXYHUWXUHDYHFOHROND simultanément sur les touches + et - sur
O·DSSDUHLOPpPRULVHUDFHSRLQWFRPPHXQHEXWpHHQ l'écran, le numéro relatif à l'anomalie en
ouvertureLQYHUVHPHQWVLODILQGHFRXUVHHVWFHOOHGH cours sera affiché.
IHUPHWXUHDYHFOHCARRÉO·DSSDUHLOODJHPpPRULVHUD 'DQVOH7DEVRQWLQGLTXpHVWRXWHVOHVDQRPDOLHVSRXYDQW
FHSRLQWFRPPHXQDUUrWHQfermeture'DQVFHWWH rWUHDIILFKpHVjO
pFUDQ
SKDVHS 3 FOLJQRWHjO
pFUDQ Tab. 5 - Erreurs
6HORQODGHUQLqUHILQGHFRXUVHDWWHLQWHO
DSSDUHLOVH
PHWWUD j O
pWDW IHUPp 0 0 RX RXYHUW 0 1 'DQV OH 0 1 &DUWHHQSDQQH
VHFRQG FDV GRQQHU XQH LPSXOVLRQ 23(1 SRXU IDLUH 0 3 0RWHXUHQSDQQH
IHUPHUOHSRUWDLO %ORFDJHPRWHXUEORTXpIHUPpFRQWU{OHUOH
0 6 EORFDJHGXPRWHXUHWpYHQWXHOOHPHQWOH
UHPSODFHU
8 TEST DE L'AUTOMATISME 3RUWDLOWURSORXUGRXIURWWHPHQWVpOHYpVWHQWHU
ÉODILQGHO
LQVWDOODWLRQHWGHODSURJUDPPDWLRQFRQWU{OHUOHERQ 0 7 G
DXJPHQWHUODIRUFHGXPRWHXU
IRQFWLRQQHPHQWGHO
LQVWDOODWLRQ9pULILHUVXUWRXWO
LQWHUYHQWLRQ (UUHXUGLVSRVLWLI%86($6<H[PrPHDGUHVVH
FRUUHFWHGHVGLVSRVLWLIVGHVpFXULWpHWYpULILHUTXHO
LQVWDOODWLRQ
UHVSHFWHOHVQRUPHVGHVpFXULWpHQYLJXHXU 0 8 VXUGHX[SDLUHVGHSKRWRFHOOXOHVYpULILHUOHV
DGUHVVHV
Nous rappelons qu’au second niveau de 1 0 /HVGHX[ILQVGHFRXUVHDYHFODPrPHSRODULWp
programmation, on dispose du paramètre
de configuration de l’encoder (paramètre 1 2 )LQGHFRXUVHHQJDJpHDXGpEXW6(783
EC). Cet encoder « virtuel » présent sur 1 5 7LPHRXWpSXLVp
la carte fonctionne comme un dispositif $EVHQFHGHFRPPXQLFDWLRQDYHFODFHQWUDOH
anti-écrasement. Si, durant la phase 9 0 6/$9(FHQWUDOH6/$9(DEVHQWH
d’ouverture ou de fermeture, le portail
heurte un obstacle, l’encoder « virtuel » 9 1 (UUHXUVXUODFHQWUDOH6/$9(
provoque l’inversion du mouvement.
Au mouvement suivant dans la même 9 2 (UUHXUVXUODFHQWUDOH6/$9(
direction, un obstacle dans la même
position provoquera l’arrêt du moteur. Les erreurs 9 0 9 1 et 9 2 s’affichent
Il est fondamental de configurer uniquement sur E721 configuré comme
correctement ce paramètre pour régler MASTER et en particulier les codes 9 1 et
la sensibilité correcte de l’encoder 9 2 indiquent des erreurs sur la centrale
« virtuel » aux éventuels obstacles durant SLAVE. Si ces erreurs s’affichent, il est
le mouvement. recommandé de vérifier le type d’erreur
sur l’afficheur de la centrale SLAVE pour
la résoudre et rétablir le fonctionnement
correct de l’installation.
E721 17 532014 - Rev. D
10 LOGIQUES DE FONCTIONNEMENT
Si la commande SAFE est activée durant
Les effets sur les autres entrées à impulsion active l’actionnement du vantail, celle-ci en provoque
sont indiqués entre parenthèses. l’inversion immédiate et complète. Lorsque
La commande CLOSE est activable sur l’entrée OPEN l’automatisme est à l’arrêt, la commande
B à partir du 2ème niveau de programmation. maintenue active en empêche l’actionnement.
LOGIQUE « E » IMPULSIONS
ETAT DE L'AUTOMATISME OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
LOGIQUE « EP » IMPULSIONS
ETAT DE L'AUTOMATISME OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
LOGIQUE « A1 » IMPULSIONS
ETAT DE L'AUTOMATISME OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
RXYUHOHSRUWDLOSDUWLHOOH
V
RXYUHHWVHUHIHUPHDSUqV PHQWHWOHIHUPHDSUqVOH DXFXQHIIHW DXFXQHIIHW DXFXQHIIHW
FERME OHWHPSVGHSDXVH DXFXQHIIHW 23(1LQKLEp 23(1LQKLEp DXFXQHIIHW 23(1LQKLEp
WHPSVGHSDXVH%
FRQWLQXHjRXYULUHW EORFDJHHWRXYHUWXUHORUV
EN OUVERTURE DXFXQHIIHW DXFXQHIIHW UHIHUPHOHSRUWDLO EORTXHOHIRQFWLRQQHPHQW YRLUSURJqPHQLYHDX GHODOLEpUDWLRQ
UHIHUPHDXVVLW{W PpPRULVH&/26(
3HQGDQWOHF\FOHG
RXYHUWXUHSDUWLHOOHXQHLPSXOVLRQG
23(1$SURYRTXHO
RXYHUWXUHWRWDOH
E721 18 532014 - Rev. D
/2*,48(©$3ª ,038/6,216
ETAT DE L'AUTOMATISME OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
RXYUHOHSRUWDLOSDUWLHO H
V
RXYUHHWVHUHIHUPHDSUqV PHQWHWO DXFXQHIIHW DXFXQHIIHW DXFXQHIIHW
FERME OHWHPSVGHSDXVH HIHUPHDSUqVOH DXFXQHIIHW 23(1LQKLEp 23(1LQKLEp DXFXQHIIHW 23(1LQKLEp
WHPSVGHSDXVH%
FRANÇAIS
OUVERT EN PAUSE UHFKDUJHOHWHPSVGH UHFKDUJHOHWHPSVGH UHIHUPHOHSRUWDLO EORTXHOHIRQFWLRQQHPHQW DXFXQHIIHW SDXVH SDXVH
SDXVH SDXVH &/26(LQKLEp &/26(LQKLEp
LOGIQUE « S » IMPULSIONS
ETAT DE L'AUTOMATISME OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
RXYUHOHSRUWDLOSDUWLHO H
V
RXYUHHWVHUHIHUPHDSUqV PHQWHWO DXFXQHIIHW DXFXQHIIHW DXFXQHIIHW
FERME OHWHPSVGHSDXVH HIHUPHDSUqVOH DXFXQHIIHW 23(1LQKLEp 23(1LQKLEp DXFXQHIIHW 23(1LQKLEp
WHPSVGHSDXVH%
FRQWLQXHjRXYULUHW EORTXHHWRXYUHORUVGHOD
EN OUVERTURE LQYHUVHHQIHUPHWXUH LQYHUVHHQIHUPHWXUH UHIHUPHOHSRUWDLO EORTXHOHIRQFWLRQQHPHQW YRLUSURJqPHQLYHDX UHIHUPHDXVVLW{W OLEpUDWLRQ
PpPRULVDWLRQ&/26(
EORTXHHWUHIHUPH
OUVERT EN PAUSE UHIHUPHOHSRUWDLO UHIHUPHOHSRUWDLO UHIHUPHOHSRUWDLO EORTXHOHIRQFWLRQQHPHQW DXFXQHIIHW LPPpGLDWHPHQWORUVGHOD EORFDJHHWIHUPHWXUHO
GHODOLEpUDWLRQ
RUV
OLEpUDWLRQ
LQYHUVHHQRXYHUWXUHYRLU EORTXHHWjODOLEpUDWLRQ
EN FERMETURE URXYUHOHSRUWDLO URXYUHOHSRUWDLO DXFXQHIIHW EORTXHOHIRQFWLRQQHPHQW DXFXQHIIHW SURJqPHQLYHWjODILQ RXYUHHWjODILQIHUPH
IHUPHLPPpGLDWHPHQW DXVVLW{W
LOGIQUE « SP » IMPULSIONS
ETAT DE L'AUTOMATISME OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
RXYUHOHSRUWDLOSDUWLHO H
V
RXYUHHWVHUHIHUPHDSUqV PHQWHWO DXFXQHIIHW DXFXQHIIHW DXFXQHIIHW
FERME OHWHPSVGHSDXVH HIHUPHDSUqVOH DXFXQHIIHW 23(1LQKLEp 23(1LQKLEp DXFXQHIIHW 23(1LQKLEp
WHPSVGHSDXVH%
EORTXHHWUHIHUPH EORTXHHWUHIHUPH
OUVERT EN PAUSE UHIHUPHOHSRUWDLO UHIHUPHOHSRUWDLO UHIHUPHOHSRUWDLO EORTXHOHIRQFWLRQQHPHQW DXFXQHIIHW LPPpGLDWHPHQWORUVGHOD LPPpGLDWHPHQWORUVGHOD
OLEpUDWLRQ OLEpUDWLRQ
3HQGDQWOHF\FOHG
RXYHUWXUHSDUWLHOOHXQHLPSXOVLRQG
23(1$SURYRTXHO
RXYHUWXUHWRWDOH
E721 19 532014 - Rev. D
LOGIQUE « SA » IMPULSIONS
ETAT DE L'AUTOMATISME OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
RXYUHOHSRUWDLOSDUWLHO H
V
RXYUHHWVHUHIHUPHDSUqV PHQWHWO DXFXQHIIHW DXFXQHIIHW DXFXQHIIHW
FERME OHWHPSVGHSDXVH HIHUPHDSUqVOH DXFXQHIIHW 23(1LQKLEp 23(1LQKLEp DXFXQHIIHW 23(1LQKLEp
WHPSVGHSDXVH%
EORFDJHHWRXYHUWXUHORUV
EN OUVERTURE DXFXQHIIHW DXFXQHIIHW UHIHUPHOHSRUWDLO EORTXHOHIRQFWLRQQHPHQW YRLUSURJqPHQLYHDX DXFXQHIIHW GHODOLEpUDWLRQ
PpPRULVH&/26(
UHFKDUJHOHWHPSVGH UHFKDUJHOHWHPSVGH
OUVERT EN PAUSE UHIHUPHOHSRUWDLO UHIHUPHOHSRUWDLO UHIHUPHOHSRUWDLO EORTXHOHIRQFWLRQQHPHQW DXFXQHIIHW SDXVH SDXVH
&/26(LQKLEp &/26(LQKLEp
LOGIQUE « B » IMPULSIONS
ETAT DE L'AUTOMATISME OPEN A / CLOSE STOP FSW OP FSW CL FSW CL/OP
EORTXHHWRXYUHORUVGHOD
EN OUVERTURE DXFXQHIIHW / IHUPHOHSRUWDLO EORTXHOHIRQFWLRQQHPHQW YRLUSURJqPHQLYHDX DXFXQHIIHW OLEpUDWLRQPpPRULVDWLRQ
23(1&/26(
EORTXHHWRXYUHORUVGHOD
EN OUVERTURE DXFXQHIIHW / IHUPHOHSRUWDLO EORTXHOHIRQFWLRQQHPHQW YRLUSURJqPHQLYHDX DXFXQHIIHW OLEpUDWLRQPpPRULVDWLRQ
23(1&/26(
3HQGDQWOHF\FOHG
RXYHUWXUHSDUWLHOOHXQHLPSXOVLRQG
23(1$SURYRTXHO
RXYHUWXUHWRWDOH
$O
DOOXPDJHODFDUWHYpULILHOHVHQWUpHVHWVLXQHFRPPDQGH23(1$RX%HVWDFWLYHHOOHRXYUHOHEDWWDQWRXOHSRUWDLODXWUHPHQWHOOHOHIHUPH
E721 20 532014 - Rev. D
INHALTSVERZEICHNIS
1 HINWEISE ........................................................................................................................................................ 2
2 ANORDNUNG UND KOMPONENTEN ................................................................................................................ 2
2.1 BESCHREIBUNG DER KOMPONENTEN ........................................................................................................................ 3
2.2 BESCHREIBUNG KLEMMENBRETT J13 ......................................................................................................................... 3
3 TECHNISCHE EIGENSCHAFTEN ........................................................................................................................ 3
4 ELEKTRISCHE ANSCHLÜSSE ............................................................................................................................. 4
4.1 FOTOZELLEN BUS-2EASY ............................................................................................................................................. 5
4.1.1 ANSTEUERUNG DER BUS-2EASY-FOTOZELLEN ................................................................................................................5
4.1.2 SPEICHERUNG BUS-2EASY-ZUBEHÖRGERÄTE .................................................................................................................5
4.2 HERKÖMMLICHE FOTOZELLEN ................................................................................................................................... 6
4.3 ANSCHLÜSSE SAFE-EINGANG ...................................................................................................................... 7
5 PROGRAMMIERUNG ...................................................................................................................................... 8
5.1. PROGRAMMIERUNG 1. STUFE .................................................................................................................................. 8
5.2 PROGRAMMIERUNG 2. STUFE ................................................................................................................................. 10
6 SPEICHERUNG DES FUNKCODES .................................................................................................................. 12
6.1 SPEICHERUNG DER DS-FUNKSTEUERUNGEN............................................................................................................. 12
6.2 SPEICHERUNG DER SLH-FUNKSTEUERUNGEN .......................................................................................................... 13
6.3 SPEICHERUNG DER LC/RC-FUNKSTEUERUNGEN (NUR AUF EINIGEN MÄRKTEN) ....................................................... 13
6.3.1 FERNSPEICHERUNG DER LC/RC-FUNKSTEUERUNGEN ..................................................................................................13
6.4 LÖSCHEN DER FUNKSTEUERUNGEN ........................................................................................................................ 13
7 INBETRIEBNAHME ......................................................................................................................................... 14
7.1 ÜBERPRÜFUNG DER LEDS .......................................................................................................................................... 14
7.2 BATTERIEBETRIEB ...................................................................................................................................... 14
7.3 POSITIONIERUNG DER ENDSCHALTER ..................................................................................................................... 15
7.4 MASTER-SLAVE-KONFIGURATION ............................................................................................................................. 16
7.4.1 MASTER-SLAVE-VERDRAHTUNG ................................................................................................................................... 16
7.4.2 SETUP-VERFAHREN MASTER/SLAVE .............................................................................................................................. 16
7.5 SETUP ....................................................................................................................................................................... 17
8 TEST DER AUTOMATION ........................................................................................................................... 17
9 ANZEIGE ALARM- UND FEHLERMELDUNGEN ................................................................................................. 17
DEUTSCH
9.1 ALARME ................................................................................................................................................................... 17
9.2 FEHLERMELDUNGEN ............................................................................................................................................... 17
10 BETRIEBSLOGIKEN ...................................................................................................................................... 18
CE-KONFORMITÄTSERKLÄRUNG
Der Hersteller: FAAC S.p.A.
Anschrift: Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALIEN
erklärt, dass: das elektronische Gerät E721
den wesentlichen Sicherheitsanforderungen der folgenden weiteren E:G-5ichtlinien
entspricht
2006/95/EG Niederspannungsrichtlinie
2004/10/EG 5ichtlinie zur elektromagnetischen Verträglichkeit
Anmerkung:
Dieses Produkt wurde in einer typisch homogenen Konfiguration getestet
(sämtliche Bauprodukte der Firma FAAC S.p.A.).
HINWEISE
Achtung! Um die Personensicherheit zu gewährleisten, sollte die Anleitung aufmerksam befolgt werden.
Eine falsche Montage oder ein falscher Einsatz des Produktes können zu schwerwiegenden Verletzungen führen.
Die Anleitung aufmerksam lesen, bevor mit der Montage des Produktes begonnen wird. Die Anleitung griffbereit
aufbewahren, um auch in Zukunft Bezug auf sie nehmen zu können.
Mit diesem Symbol werden wichtige Hinweise in Bezug auf die Personensicherheit und die Unversehrtheit der
Automation gekennzeichnet.
Mit diesem Symbol soll auf die Hinweise in Bezug auf die Eigenschaften bzw. den Betrieb des Produktes
aufmerksam gemacht werden.
/ SAFE
/ SAFE
SENSOR
DEUTSCH
ENDSCHALTER
Fig.
Abb.11
DEUTSCH
Ver- und Entriegelung des Motors,
vollständige gffnen des Tors sorgt Motorverriegelung, USB
2-6 GND Negativ Versorgung Ein-/Ausgänge auf BUS-2EAS<, OPEN A, OPEN B/CLOSE/
Zubehörgeräte dem Klemmenbrett SAFE, STOP/SAFE, GND, Fotozellen zum
3(1) OPEN B Vorrichtung mit Schliesserkontakt, gffnen und Schließen, +24 V, Strom-
(DEFAULT) die die teilweise gffnung des Tors versorgung, Blinkleuchte, elektrische
bewirkt Entriegelung Motorverriegelung, OUT
/ SAFE
/ SAFE
230 V ~
115 V ~
=
KONTAKT
MOTORENTRIEGELUNG
(Blockiert den Motor,
wenn der Griff für die
Entriegelung des Motors
= betätigt wird)
Abb.
Fig. 2
DEUTSCH
E721
E721 E721
E721
C720
C 72 C721
C 721
Abb.
Fig.
Abb.
Fig. 44
DEUTSCH
DL1
ON
DS1
ON
DS1 Schalter für die 4. Die Karte an die Versorgung anschließen.
Programmie- 5. Einmal kurz die SETUP-Taste drücken (S:4), um die
1 2 3 4 1 2 3 4
DL2
BUS BUS BUS BUS rung Einschreibung der Zubehörgeräte durchzuführen.
hberprüfen, ob die montierten BUS-2EAS<-Vorrichtungen
RX - TX ordnungsgemäß funktionieren.
6. Die BUS-2EAS<-Zubehörteile wurden von der Karte
gespeichert.
Die Angaben der folgenden Tabelle befolgen, um zu
4.1.1 ANSTEUERUNG DER BUS-2EASY-FOTOZELLEN überprüfen, ob die BUS-2EAS<-Anschluss ordnungsgemäß
Es ist wichtig, dass sowohl dem Geber als funktioniert.
auch dem Empfänger dieselbe Adresse Dieselben Anweisungen sind an einem
gegeben wird. MASTER-Steuergerät zu befolgen, auch um
Sicherstellen, dass nicht zwei bzw. mehrere ein an den BUS-2EASY mit POLARISIERTEM
Fotozellenpaare dieselbe Adresse haben. Kabel angeschlossenes SLAVE-Steuergerät
Wenn kein BUS-2EASY-Zubehör verwendet zu erfassen.
wird, bleibt der BUS-2EASY-Stecker (J12 - Tab. 2 - Beschreibung BUS-2EASY-LED
Abb. 1) unbelegt
Normale Aktivität (LED eingeschaltet, auch
Dauerhaft
wenn keine Fotozellen vorhanden sind). Keine
eingeschaltet
angesteuerte Fotozelle belegt.
Blinkt Mindestens eine angesteuerte Fotozelle belegt
langsam bzw. nicht ausgerichtet.
Ausgeschaltet
(blinkt alle Kurzschluss BUS-2EAS<-Leitung.
2,5 sec)
- BUS-2EAS<-Leitung deaktiviert (keine
Versorgung)
Ausgeschaltet
- Batteriebetrieb
- Steuergerät als SLAVE programmiert
OUT
Andere Sicher-
heitsvorrichtungen
OUT
OUT
Andere Sicher-
heitsvorrichtungen
Abb. 6
DEUTSCH
Andere Sicher-
heitsvorrichtungen
Abb. 7 Abb. 10
E721 6 532014 - Rev. D
Anschluss eines Fotozellenpaars beim Schließvorgang, eines Paars beim Keine Sicherheits- bzw. Stoppvorrichtung angeschlossen
gffnungsvorgang sowie eines Paars beim gffnungs-/Schließvorgang
Abb. 12
Abb. 11
DEUTSCH
Andere
Andere Sicherheitseinrichtungen
Sicherheitseinrichtungen OPEN A
OPEN A
GND GND
OPEN B / CLOSE - OUT SAFE / OPEN B / CLOSE
- OUT SAFE / STOP STOP
FSW OP FSW OP
GND GND
FSW CL FSW CL
+24V +24V Abb. 1
Wenn die FailSafe-Sicherheitsfunktion deaktiviert wird (Parameter kann in der 2. Programmierstufe festgelegt
werden) muss - als Minuspol für die Verwaltung des SAFE-Eingangs verwendet werden (siehe Abb. 14).
DEUTSCH
bei 99 % in 1%-Schritten.
PROGRAMMIERUNG 2. STUFE
sofort umgekehrt.
Y = Umkehr beim Freiwerden
n o = Unverzügliche Umkehr während des gffnungsvorgangs.
Im SLAVE-Modus nicht angezeigter Parameter
PHOTOZELLEN WÄHREND DER ÖFFNUNG:
oP Die Funktion aktivieren, wenn die Fotozellen für den gffnungsvorgang die Bewegung
no
blockieren und die Bewegung beim Schließvorgang umkehren sollen. :enn diese Funktion
deaktiviert ist und die Fotozellen im gffnungsvorgang ausgelöst werden, läuft bei ihrem
Freiwerden normalerweise der Motor an.
Y = Unverzügliche Umkehr während des Schließvorgangs
n o = Anlauf der Bewegung beim Freiwerden.
Im SLAVE-Modus nicht angezeigter Parameter
FUNKTION ADMAP:
Ad Ermöglicht es, den Betrieb gemäß der französischen 5ichtlinie NFP 25/62 zu aktivieren.
no
Y = aktiv
n o = deaktiviert
ENCODER:
EC Der sich auf der Karte befindliche Åvirtuelle“ Geber (Encoder) dient als Sicherheitsvorrichtung für den 02
Quetschschutz und verwaltet die Punkte, an denen das Abbremsen und die Teilöffnung beginnen.
:enn das Tor während des gffnungs- bzw. Schließvorgangs gegen ein Hindernis stößt, sorgt der
Åvirtuelle“ Geber dafür, dass die Bewegung umgekehrt wird. :enn für dieselbe 5ichtung ein zweites
Hindernis geortet wird, hält der Motor an. In beiden Fällen wird ein Alarm angezeigt (siehe Abschnitt
Alarme).
Die Empfindlichkeit des Åvirtuellen“ Gebers muss eingestellt werden, wobei der Zeitraum, den die
Karte wartet, bevor die Umkehr der Bewegung veranlasst wird, von einem Minimum von 0 sec
bis zu einem Maximum von 10 sec in Schritten von einer Sekunde reichen kann.
00 = höchste Empfindlichkeit
10 = niedrigste Empfindlichkeit
E721 10 532014 - Rev. D
Display Funktion Default 1
TEILÖFFNUNG:
PO Die :eite der Teilöffnung des Flügels kann als Prozentsatz des vollständigen Torlaufs eingestellt werden.
50
Einstellbar von 0 bis 99% in 1%-Schritten.
00 = keine Teilöffnung
01 = minimale Teilöffnung
99 = maximale Teilöffnung
ARBEITSZEIT (Time-Out):
t Es muss ein :ert eingestellt werden, der höher als die Zeit ist, die das Tor zum vollständigen 2.0
gffnen und Schließen benötigt.
Einstellbar von 0 bis 59 sec in Schritten von 1 Sekunde. Nachfolgend schaltet die Anzeige
auf Minuten und Zehntelsekunden um (die durch einen Punkt getrennt sind) und die Zeit wird
mit Schritten von jeweils 10 Sekunden bis zum maximalen :ert von 9.5 Minuten eingestellt.
Z.B.: :enn das Display 2.5 anzeigt, beträgt die Pausenzeit 2 min und 50 sec..
Bei Anlagen mit MASTER-SLAVE-Konfiguration muss am MASTER-Steuergerät
eine BETRIEBSZEIT eingestellt werden, bei der die Bewegungsdauer beider Flügel
zu berücksichtigen ist.
OUT 1:
o1 Ermöglicht es, den Ausgang OUT (Open Collector 5UHEST5OMKONTAKT) in einer der folgenden 00
Funktionen zu aktivieren:
00 = Immer aktiv (liefert 24-V-Spannung = bei maximaler Stromaufnahme 100 mA)
01 = FAILSAFE (prüft den einwandfreien Betrieb der angeschlossenen herkömmlichen Fotozellen)
02 = KONT5OLLLAMPE (bei geschlossenem Tor ausgeschaltet, in der Schließphase und der Pause
eingeschaltet, in der Schließphase blinkend)
03 = SE5VICELAMPE (siehe folgende Funktion)
04 = ALA5M BATTE5IE-Betrieb
05 = Tor GEgFFNET bzw. in PAUSE
06 = Tor GESCHLOSSEN
07 = Tor in BE:EGUNG
08 = Tor in der gFFNUNGSPHASE
09 = Tor in der SCHLIESSPHASE
1 0 = Sicherheitsvorrichtung AKTIV
1 1 = Getakteter Ausgang, der vom zweiten Funkkanal aus aktiviert werden kann (siehe
nachfolgende Funktion)
1 2 = Ausgang, der vom zweiten Funkkanal aus aktiviert werden kann (Funktion Schrittbetrieb)
t1 VERZÖGERUNGSZEIT OUT 1 (nur sichtbar, wenn im vorangegangenen Schritt Punkt 03 bzw. 02
DEUTSCH
11 ) ausgewählt wurden:
Ermöglicht es, die Verzögerungszeit des Ausgangs OUT einzustellen, wenn eine Zeitfunktion
(Z.B. 03 bzw. 11 ) von 1 bis 99 Minuten in Schritten von 1 Minute ausgewählt wurde.
OPEN B / CLOSE/SICHERHEITSVORR. LEISTE E:
Ob Die Benutzung des Eingangs OPEN B kann als Teilöffnung bzw. SCHLIESS-Impuls ausgewählt 00
werden, oder SICHE5HEITSVO55. LEISTE.
00 = OPEN B
01 = CLOSE
02 = SICHE5HEITSLEISTE (gffnerkontakt)
Sollte eine Betriebslogik ausgewählt werden, die den Einsatz des SCHLIESS-Impulses
vorsieht (Logik b, bC, C), wird diese Funktion auf 01 voreingestellt und kann nicht
verändert werden.
STOP / SICHERHEITSVORR. LEISTE:
SP Die Benutzung des Eingangs STOP kann als STOP oder SICHE5HEITSVO55. LEISTE-Impuls aus- 00
gewählt werden.
00 = STOP
01 = SICHE5HEITSLEISTE (gffnerkontakt)
TEILUMKEHRUNG:
IP Es besteht die Möglichkeit, den Umkehrungstyp (vollständige Umkehrung oder Teilumkehrung) no
beim Erfassen eines Hindernisses oder dem Ansprechen der Sicherheitsleiste auszuwählen.
Y = Teilumkehrung aktiviert. Beim Erfassen eines Hindernisses oder beim Ansprechen
der Sicherheitsleiste wird die Bewegungsrichtung des Flügels für zirka 2“ umgekehrt,
und anschließend kommt dieser zum Stillstand
n o = Teilumkehrung deaktiviert. Beim Erfassen eines Hindernisses oder beim Ansprechen der
Sicherheitsleiste wird die Bewegungsrichtung des Flügels vollständig umgekehrt, und
dieser wird in die gffnungs- oder Schließposition gefahren.
MOTORVERRIEGELUNG:
Lc Es ist möglich, den Einsatz der Motorverriegelung während des Batteriebetriebs auszuwählen: Y
Y = die Motorverriegelung funktioniert auch während des Batteriebetriebs regelmäßig weiter
no = im Batteriebetrieb bleibt die Motorverriegelung stets geöffnet
E721 11 532014 - Rev. D
Display Funktion Default 1
KUNDENDIENSTANFORDERUNG - ZYKLUSZÄHLER (an die nachfolgenden Funktionen gekoppelt):
AS Y = beim Erreichen der Anzahl der Zyklen, die zusammen mit den nachfolgenden no
Funktionen nc und nd eingestellt werden können, wird vor sämtlichen Bewegungen
ein Vorblinkvorgang von 8 sec durchgeführt (abgesehen von dem bereits mit der
Funktion PF eingestellten Vorblinkvorgang).
no = die darauffolgenden Funktionen nc und nd zeigen an, wie viele Zyklen die Anlage
bis zu einem Maximum von 99Ü990 durchgeführt hat.
Wenn die Anzahl der durchgeführten Zyklen höher als 99 990 ist, zeigen die
beiden darauffolgenden Funktionen nc und nd beide 99 an.
Diese Funktion kann nützlich sein, um die Intervalle der programmierten Instandhaltung
einzustellen bzw. um die bereits durchgeführten Zyklen zu überprüfen.
ZYKLUSPROGRAMMIERUNG (MAL TAUSEND):
nc :enn AS
= Y zeigt das Display die Anzahl der Zyklen mal Tausend an, nach denen der
00
Kundendienst angefordert werden soll (einstellbar von 0 bis 99 ).
:enn A S = n o zeigt das Display die Anzahl der Zyklen mal Tausend an, die bereits
durchgeführt wurden. Der angezeigte :ert wird bei jedem Zyklus aktualisiert und
interagiert mit dem nd -:ert.
Wenn AS = no wird durch einen 5-sec-langen Druck der Tasten + und - der
Zykluszähler nullgestellt.
ZYKLUSPROGRAMMIERUNG (MAL ZEHN):
nd :enn AS = Y zeigt das Display die Anzahl Zyklen mal Zehn an, nach denen der Kundendienst
00
angefordert werden soll (einstellbar von 0 bis 99 ).
:enn AS = no zeigt das Display die Anzahl der Zyklen mal Zehn an, die bereits durchgeführt
wurden. Der angezeigte :ert wird bei jedem Zyklus aktualisiert und interagiert mit dem
nc -:ert.
Beispiel: Wenn die Anlage 11 218 Zyklen durchgeführt hat, werden
nc = 11 und nd = 21 angezeigt
STATUS DER AUTOMATION:
St Verlassen der Programmierung, Speichern der Daten und 5ückkehr zur Anzeige des Status der Automation.
DEUTSCH
halten, bis beide LEDs 5 sec lang langsam blinken.
Um die anderen Funksteuerungen mit demselben . Innerhalb von 5 sec die zuvor gespeicherte Taste der
Anlagencode zu aktivieren, muss der Anlagencode der Funksteuerung drücken, um die Lernphase auf dem
gespeicherten Taste der Funksteuerung an die Taste der ausgewählten Kanal zu aktivieren.
Funksteuerung, die hinzugefügt werden soll, übermittelt 4. Die LED auf der Karte, welche dem in der Lernphase
werden. Hierzu muss folgendermaßen vorgegangen befindlichen Kanal entspricht, blinkt 5 sec lang,
werden: während derer der Code einer anderen Funksteuerung
a. Die Tasten P1 und P2 auf der gespeicherten übermittelt werden muss.
Funksteuerung gleichzeitig drücken und gedrückt 5. Die LED leuchtet dauerhaft 1 Sekunde lang und zeigt
halten. an, dass die Speicherung erfolgt ist. Dann blinkt sie
b. Die LED der Funksteuerung beginnt zu blinken. weitere 5 sec, während derer andere Funksteuerungen
gespeichert werden können.
c. Beide Tasten loslassen.
d. Die gespeicherte Taste drücken und gedrückt 6.4 LÖSCHEN DER FUNKSTEUERUNGEN
halten (die LED der Funksteuerung leuchtet Um ALLE Codes der eingegebenen Funksteuerungen zu
dauerhaft). löschen, müssen die beiden Tasten + (S:) und - (S:2)
e. Die Funksteuerungen einander nähern, die Taste gedrückt werden. Dann eine Sekunde lang die SETUP-Taste
der Funksteuerung, die hinzugefügt werden soll, (S:4) und die beiden ersten Tasten 10 sec lang drücken
drücken und gedrückt halten und erst dann wieder werden.
loslassen, wenn die LED der Funksteuerung anzeigt, Die LEDs 5ADIO1 und 5ADIO2 blinken 10 sec lang
dass die Speicherung erfolgt ist. schnell.
f. Die Taste der gespeicherten Funksteuerung 2 Mal Die beiden LEDs leuchten 2 Sekunden lang und gehen
kurz hintereinander drücken. dann aus (Löschung erfolgt).
Die Automation öffnet sich. Sicherstellen, Beide Tasten loslassen.
dass die Automation frei von Hindernissen
Dieser Vorgang kann NICHT rückgängig
(Personen bzw. Gegenstände) ist.
gemacht werden. Es werden sämtliche
sowohl als OPEN A als auch als OPEN B/CLOSE
gespeicherten Codes der Funksteuerungen
gelöscht.
E721 13 532014 - Rev. D
7 INBETRIEBNAHME
7.1 ÜBERPRÜFUNG DER LEDS
Nachdem sämtliche Anschlüsse durchgeführt worden sind und die Karte mit Strom versorgt ist, muss in der unten
aufgeführten Tabelle der Status der LEDs im Vergleich zum Status der Eingänge überprüft werden (auf Abb. 16 ist die
Automation geschlossen und befindet sich in 5uhestellung).
Die LEDs zeigen den Status der Eingänge der Karte an und sind zum Bewegen des Automatismus von großer Bedeutung:
Dabei ist zu berücksichtigen, dass: LED AN = Kontakt geschlossen LED AUS = Kontakt offen
< (1) F
BUS 2EASY
< (2)
< OPEN A -
< GND
< OPEN B / CLOSE < SAFE
+
R
A
C
1
RADIO XF
R
2
IO
E
FC
FC
IO
O
< STOP / SAFE
W
R
D
O
R
A
P
R
< FSW OP
R
SETUP
< GND
< FSW CL
< +24
USB
BATTERY
RELEASE
Y
R
)
R
F
OUT
-L
E
S
S
E IN
TO
R M
K
K
K
T
-N
N
T EC
C
T
T RI
C
C
(P A
- +
A
LO
LA
LO
LO
M
R
P
M
B
<
<
<
<
<
<
<
<
<
Fig. 16
Abb. 16
Die LEDs FCA und FCC stellen die Arbeitskontakte des Die Eingänge STOP (SAFE), FSW CL, FSW
auf der Karte integrierten Endschalters dar, die sich im OP, OPEN B, konfiguriert als SAFE, sind
DEUTSCH
ACHTUNG
:ährend des Batteriebetriebs bei stehender Automation und System im 5uhemodus ist das Display LCD1 abgeschaltet und
die LED BUS 2easy sowie die LED FCC und FCA leuchten nicht, während die LED Power blinkt, um den Verbrauch zu optimieren
und die Ladung aufrechtzuerhalten.
In dieser Phase besteht auf jeden Fall die Möglichkeit, den Zustand der Automation anzuzeigen. Hierfür einfach kurz die
Taste + auf der Steuerkarte drücken. Nach diesem kurzen Tastendruck wird der Zustand der Automation für 2 Sekunden am
Display LCD1 angezeigt, das danach wieder abgeschaltet wird. :ährend einer normalen Bewegung arbeiten dagegen alle
Diagnose-LED und LED zur Statusanzeige des Displays wieder entsprechend dem Zustand der Automation (siehe Abb. 16).
E721 14 532014 - Rev. D
7.3 POSITIONIERUNG DER ENDSCHALTER
Um die Endschalter-Magneten ordnungsgemäß positionieren zu können, muss die Steuerzentrale
vorschriftsmäßig montiert und mit sämtlichen Zubehörgeräten der Steuerzentrale und den
Sicherheitsvorrichtungen verbunden werden.
Der Antrieb ist mit einem Magnetsensor (Endschalter) ausgestattet, welcher in der Karte der Steuerung integriert ist.
Der Stillstand des Tors erfolgt sowohl beim gffnen als auch beim Schließen in dem Moment, in dem der Sensor von dem
am oberen Teil der Zahnstange befestigten polarisierten Magneten, aktiviert wird.
1. Überprüfen, ob der Antrieb gemäß der entsprechenden Anleitungen für den manuellen Betrieb
eingerichtet ist.
2. Das Tor von Hand in die Öffnungsposition schieben und dabei einen Abstand von 40 mm zum
mechanischen Endanschlag lassen (siehe Abb. 17).
. Den Magneten mit dem RUNDEN ENDE auf der Zahnstange in 5ichtung des Motors gleiten
A
C
R O1
2
FC
FC
IO
I
lassen. Sobald die LED des FCA-Endschalters auf der Karte erlischt, kann dieser mit den
R
A
E
R
entsprechenden Schrauben befestigt werden.
4. Das Tor von Hand in die Schließposition schieben und dabei einen Abstand 40 mm zum
mechanischen Endanschlag lassen.
5. Den Magneten mit dem QUADRATISCHEN ENDE auf der Zahnstange in 5ichtung des Motors
gleiten lassen. Sobald das LED des FCC-Endschalters auf der Leiterplatte ausgeht, mit den
entsprechenden Schrauben befestigen.
A
C
R O1
2
FC
FC
IO
6. Sowohl beim gffnen als auch beim Schließen überprüfen, ob die LED des entsprechenden
I
D
R
A
Endschalters sich am Ende des Vorgangs ordnungsgemäß ausschaltet und falls notwendig die
E
R
entsprechenden bnderungen an der Position der Endschaltermagneten vornehmen.
Um eine Beschädigung des Antriebs und/oder Betriebsstörungen an der
Automation zu vermeiden, muss ein Abstand von etwa 40 mm zu den
mechanischen Endanschlägen gewahrt werden.
DEUTSCH
SCHLIESSVORGANG benutzt
werden.
(SIEHE ABB. 17)
Bei Anlagen mit MASTER-
SLAVE-Konfiguration müssen
die Magneten der Endschalter
gemäß den Anweisungen in
Abb. 18 eingebaut werden.
Abb, 17
MASTER/SLAVE
Abb. 18
Anschlüsse und Verdrahtungen für das SLAVE-Gerät auf der Klemmenleiste J13 sind zu vermeiden.
Die BUS-Verbindung zwischen den beiden Steuerkarten muss POLARISIERT sein, wobei die
Reihenfolge der Pole der Klemmenleiste J12 einzuhalten ist (POL (1) – POL (2)) – (siehe Abb. 19).
Bei der Konfiguration eines Steuergeräts als SLAVE werden die Werte einiger Programmierparameter
forciert und nicht mehr im Menü visualisiert (LO-PA-Pb-Ph-Op). Wird für die Steuerkarte erneut
der MASTER-Modus festgelegt, werden diese zuvor forcierten Werte in der Programmierung
beibehalten.
7.4.1 MASTER-SLAVE-VERDRAHTUNG
(1) (1)
BUS 2 EASY BUS 2 EASY
(2) (2)
Keine Anschlüsse an
diese Klemmenleiste
vornehmen.
DEUTSCH
Die SETUP-Anforderung, die durch das Blinken der Meldung S0 am Display angezeigt wird,
kann sowohl am MASTER-Steuergerät als auch am SLAVE-Steuergerät erscheinen. Wird sie am
SLAVE-Steuergerät visualisiert, erscheint am MASTER-Steuergerät der Fehlercode 91 . Auf jeden
Fall kann ein SETUP-Vorgang ausschließlich am MASTER-Steuergerät gestartet werden.
Für den SETUP-Vorgang bei einer MASTE5-SLAVE-Anlage sind folgende Schritte auszuführen:
1. Beide Flügel entriegeln, auf halben Hubweg fahren und wieder verriegeln (siehe Anweisung Nr. 1, Abschn. 7.5 SETUP)
2. Die SETUP-Taste am MASTE5-Steuergerät so lange drücken, bis das MASTE5-Tor die Bewegung startet.
. Das MASTE5-Tor führt einen vollständigen SETUP-Vorgang durch (siehe Abschn. 7.5 SETUP)
4. Nachdem der SETUP-Vorgang der MASTE5-Steuerkarte ordnungsgemäß abgeschlossen wurde, startet der komplette
SETUP-Vorgang der SLAVE-Steuerkarte (siehe Abschn. 7.5 SETUP).
5. :urde auch dieser Vorgang abgeschlossen, prüft das MASTE5-Steuergerät die Position des SLAVE-Flügels und fährt
diesen an dieselbe Position (offen oder geschlossen) des MASTE5-Flügels.
6. Vorgang abgeschlossen.
Bei Fehlern oder wurde der oben beschriebene SETUP-Vorgang nicht vollständig abgeschlossen,
sind die Schritte ab Punkt 1 zu wiederholen.
DEUTSCH
Anschlagstelle für die Schließphase. In dieser Phase blinkt
auf dem Display die Anzeige S3. Die Tab. 5 enthält sämtliche Fehlermeldungen, die auf
4. Je nach dem letzten erreichten Endschalter geht das dem Display angezeigt werden können.
Gerät in den geschlossenen (00) bzw. den geöffneten Tab. 5 - Fehlermeldungen
Status (01) über. Im zweiten Fall muss ein OPEN-Impuls
gegeben werden, damit sich das Tor schließt. 01 Karte defekt
03 Motor defekt
8 TEST DER AUTOMATION Motorverriegelung blockiert geschlossen (die Motor-
Am Ende der Montage und der Programmierung den ord- 06 verriegelung überprüfen und eventuell austauschen)
nungsgemäßen Betrieb der Anlage kontrollieren. Hierbei Das Tor ist schwer zu fahren bzw. weist eine hohe
vor allem überprüfen, ob die Sicherheitsvorrichtungen ord- 07 mechanische Schwergängigkeit auf (versuchen, die
Motorkraft zu erhöhen)
nungsgemäß funktionieren und die Anlage den geltenden
Fehler BUS-2EAS<-Vorrichtung (z.B.: dieselbe Adresse
Sicherheitsrichtlinien entspricht. 08 auf zwei Fotozellenpaaren; Adressen überprüfen)
Es wird darauf hingewiesen, dass der 10 Beide Endschalter haben dieselben Pole
Parameter für die Konfiguration des
Encoders in der zweiten Programmierstufe 12 Endschalter beim SETUP-Beginn belegt
zur Verfügung steht (Paramete rEC). Dieser 15 Time-Out abgelaufen
„virtuelle“ Encoder auf der Steuerkarte Keine Kommunikation mit dem SLAVE-Steuergerät –
dient als Quetschschutz. Wenn das Tor 90 kein SLAVE-Steuergerät angeschlossen
während des Öffnens oder Schließens
gegen ein Hindernis stößt, bewirkt der 91 Fehler am SLAVE-Steuergerät
„virtuelle“ Encoder die Umkehrung der
Bewegungsrichtung. Bei der nächsten 92 Fehler am SLAVE-Steuergerät
Bewegung in dieselbe Richtung bewirkt Die Fehlercodes 9 0 9 1 und 9 2 werden nur
ein Hindernis an derselben Position die an als MASTER konfigurierten E721-Geräten
Stillsetzung des Motors. Die korrekte angezeigt; insbesondere verweisen die Codes
E i n s t e l l u n g d i e s e s Pa r a m e t e r s z u r 9 1 und 9 2 auf Fehler am SLAVE-Steuergerät.
Regelung der korrekten Empfindlichkeit Werden diese Fehler angezeigt, zum Beheben
des „virtuellen“ Encoders auf eventuelle der Störung und Wiederherstellung des
Hindernisse während der Bewegung ist von einwandfreien Betriebs der Anlage den am
grundlegender Bedeutung. Display des SLAVE-Steuergeräts visualisierten
Fehlertyp überprüfen.
GESCHLOSSEN öffnet das Tor öffnet das Tor teilweise keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN unterdrückt) (OPEN unterdrückt) (OPEN unterdrückt)
GEgFFNET schließt das Tor wieder (1) schließt das Tor wieder schließt das Tor wieder keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
IM SCHLIESSVO5GANG öffnet das Tor wieder öffnet das Tor wieder keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe blockiert und öffnet sich
beim Freiwerden (OPEN
Prog. 2. Stufe) blockiert - speichert CLOSE)
BLOCKIE5T schließt das Tor schließt das Tor schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung (OPEN
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) blockiert - speichert CLOSE)
GESCHLOSSEN öffnet das Tor öffnet das Tor teilweise keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN unterdrückt) (OPEN unterdrückt) (OPEN unterdrückt)
GEÖFFNET schließt das Tor wieder (1) schließt das Tor wieder schließt das Tor wieder keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
IM SCHLIESSVORGANG blockiert den Betrieb blockiert den Betrieb keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe blockiert und öffnet sich
beim Freiwerden (OPEN
Prog. 2. Stufe) blockiert - speichert CLOSE)
Führt die Bewegung weiter Führt die Bewegung weiter
BLOCKIERT in umgekehrter 5ichtung in umgekehrter 5ichtung schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung (OPEN
aus. Nach dem STOP aus. Nach dem STOP (OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) blockiert - speichert CLOSE)
schließt das Tor immer. schließt das Tor immer.
DEUTSCH
GEÖFFNET IN PAUSE Erneuter Ablauf Pausenzeit Erneuter Ablauf Pausenzeit schließt das Tor wieder blockiert den Betrieb keine Auswirkung Erneuter Ablauf Pausenzeit Erneuter Ablauf Pausenzeit
(1) B (CLOSE unterdrückt) (CLOSE unterdrückt)
IM SCHLIESSVORGANG öffnet das Tor wieder öffnet das Tor wieder keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe blockiert und öffnet sich
beim Freiwerden
Prog. 2. Stufe) (speichert CLOSE)
BLOCKIERT schließt das Tor schließt das Tor schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
IM ÖFFNUNGSVORGANG keine Auswirkung (1) keine Auswirkung schließt das Tor wieder blockiert den Betrieb Siehe Prog. 2. Stufe öffnet sich weiter und blockiert und öffnet sich
beim Freiwerden
schließt sich sofort wieder (speichert CLOSE)
Erneuter Ablauf Pausenzeit Erneuter Ablauf Pausenzeit schließt das Tor wieder blockiert und beim
GEÖFFNET IN PAUSE (1) B blockiert den Betrieb keine Auswirkung Freiwerden schließt es Erneuter Ablauf Pausenzeit
(CLOSE unterdrückt)
sich sofort
IM SCHLIESSVORGANG öffnet das Tor wieder öffnet das Tor wieder keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe blockiert und öffnet sich
beim Freiwerden
Prog. 2. Stufe) (speichert CLOSE)
BLOCKIERT schließt das Tor schließt das Tor schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
(1) :ährend des Teilöffnungszyklus wird das Tor durch einen OPEN-A-Impuls vollständig geöffnet.
E721 18 532014 - Rev. D
LOGIK „AP“ IMPULSE
AUTOMATIONSSTATUS OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
öffnet das Tor teilweise
öffnet und schließt nach und keine Auswirkung keine Auswirkung keine Auswirkung
GESCHLOSSEN der Pausenzeit wieder schließt es nach der keine Auswirkung (OPEN unterdrückt) (OPEN unterdrückt) keine Auswirkung (OPEN unterdrückt)
Pausenzeit B
blockiert und öffnet sich
IM ÖFFNUNGSVORGANG blockiert den Betrieb (1) blockiert den Betrieb schließt das Tor wieder blockiert den Betrieb Siehe Prog. 2. Stufe keine Auswirkung beim Freiwerden (OPEN
blockiert - speichert CLOSE)
GEÖFFNET IN PAUSE blockiert den Betrieb (1) blockiert den Betrieb schließt das Tor wieder blockiert den Betrieb keine Auswirkung Erneuter Ablauf Pausenzeit Erneuter Ablauf Pausenzeit
(CLOSE unterdrückt) (CLOSE unterdrückt)
IM SCHLIESSVORGANG öffnet das Tor wieder öffnet das Tor wieder keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe blbeiockiert und öffnet sich
m Freiwerden (OPEN
Prog. 2. Stufe) blockiert - speichert CLOSE)
BLOCKIERT schließt das Tor schließt das Tor schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
GEÖFFNET IN PAUSE Erneuter Ablauf Pausenzeit Erneuter Ablauf Pausenzeit schließt das Tor wieder blockiert den Betrieb keine Auswirkung Erneuter Ablauf Pausenzeit Erneuter Ablauf Pausenzeit
(1) (CLOSE unterdrückt) (CLOSE unterdrückt)
IM SCHLIESSVORGANG öffnet das Tor wieder öffnet das Tor wieder keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe blockiert und öffnet sich
beim Freiwerden
Prog. 2. Stufe) (speichert CLOSE)
BLOCKIERT schließt das Tor schließt das Tor schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
DEUTSCH
der Pausenzeit wieder Pausenzeit B (OPEN unterdrückt) (OPEN unterdrückt) (OPEN unterdrückt)
IM ÖFFNUNGSVORGANG Schlkehrt während des kehrt während des schließt das Tor wieder blockiert den Betrieb Siehe Prog. 2. Stufe öffnet sich weiter und blockiert und öffnet sich
beim Freiwerden
ießvorgangs um (1) Schließvorgangs um schließt sich sofort wieder (speichert CLOSE)
blockiert und beim blockiert und schließt sich
GEÖFFNET IN PAUSE schließt das Tor wieder (1) schließt das Tor wieder schließt das Tor wieder blockiert den Betrieb keine Auswirkung Freiwerden schließt es beim Freiwerden
sich sofort
kehrt die gffnung um (siehe blockiert und öffnet sich
IM SCHLIESSVORGANG öffnet das Tor wieder öffnet das Tor wieder keine Auswirkung blockiert den Betrieb keine Auswirkung Prog. 2. Stufe) am Ende beim Freiwerden und am
schließt es sich sofort Ende schließt es sich sofort
BLOCKIERT schließt das Tor schließt das Tor schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
IM SCHLIESSVORGANG blockiert den Betrieb blockiert den Betrieb keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe blockiert und öffnet sich
beim Freiwerden
Prog. 2. Stufe) (speichert CLOSE)
Führt die Bewegung weiter Führt die Bewegung weiter
BLOCKIERT in umgekehrter 5ichtung in umgekehrter 5ichtung schließt das Tor wieder keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
aus. Nach dem STOP aus. Nach dem STOP (OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
schließt das Tor immer schließt das Tor immer
(1) :ährend des Teilöffnungszyklus wird das Tor durch einen OPEN-A-Impuls vollständig geöffnet.
E721 19 532014 - Rev. D
LOGIK „SA“ IMPULSE
AUTOMATIONSSTATUS OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
öffnet das Tor teilweise
öffnet und schließt nach und keine Auswirkung keine Auswirkung keine Auswirkung
GESCHLOSSEN der Pausenzeit wieder schließt es nach der keine Auswirkung (OPEN unterdrückt) (OPEN unterdrückt) keine Auswirkung (OPEN unterdrückt)
Pausenzeit B
blockiert und öffnet sich
IM ÖFFNUNGSVORGANG keine Auswirkung (1) keine Auswirkung schließt das Tor wieder blockiert den Betrieb Siehe Prog. 2. Stufe keine Auswirkung beim Freiwerden
(speichert CLOSE)
GEÖFFNET IN PAUSE schließt das Tor wieder (1) schließt das Tor wieder schließt das Tor wieder blockiert den Betrieb keine Auswirkung Erneuter Ablauf Pausenzeit Erneuter Ablauf Pausenzeit
(CLOSE unterdrückt) (CLOSE unterdrückt)
IM SCHLIESSVORGANG öffnet das Tor wieder öffnet das Tor wieder keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe blockiert und öffnet sich
beim Freiwerden
Prog. 2. Stufe) (speichert CLOSE)
BLOCKIERT schließt das Tor schließt das Tor schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
GESCHLOSSEN öffnet das Tor / keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN unterdrückt) (OPEN unterdrückt) (OPEN unterdrückt)
GEÖFFNET keine Auswirkung / schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
IM SCHLIESSVORGANG öffnet das Tor / keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe beiblmockiFreiertwund öffnet sich
erden (speichert
Prog. 2. Stufe) OPEN/CLOSE)
BLOCKIERT öffnet das Tor / schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
GESCHLOSSEN öffnet das Tor / keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
DEUTSCH
GEÖFFNET keine Auswirkung / schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
IM SCHLIESSVORGANG öffnet das Tor / keine Auswirkung blockiert den Betrieb keine Auswirkung kehrt die gffnung um (siehe beiblmockiFreiertwund öffnet sich
erden (speichert
Prog. 2. Stufe) OPEN/CLOSE)
BLOCKIERT öffnet das Tor / schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
GESCHLOSSEN öffnet das Tor / keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN unterdrückt) (OPEN unterdrückt) (OPEN unterdrückt)
IM ÖFFNUNGSVORGANG keine Auswirkung / schließt das Tor blockiert den Betrieb Siehe Prog. 2. Stufe keine Auswirkung blockiert und beim Freiwer-
den siehe Prog. 2. Stufe
GEÖFFNET keine Auswirkung / schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
IM SCHLIESSVORGANG öffnet das Tor / keine Auswirkung blockiert den Betrieb keine Auswirkung blockiert den Betrieb blockiert den Betrieb
BLOCKIERT öffnet das Tor / schließt das Tor keine Auswirkung keine Auswirkung keine Auswirkung keine Auswirkung
(OPEN/CLOSE unterdrückt) (OPEN unterdrückt) (CLOSE unterdrückt) (OPEN/CLOSE unterdrückt)
(1) :ährend des Teilöffnungszyklus wird das Tor durch einen OPEN-A-Impuls vollständig geöffnet.
(2) Beim Einschalten werden von der Karte die Eingänge überprüft, und wenn ein OPEN-A- bzw. ein OPEN-B-Befehl aktiv ist, öffnen sich der Flügel
bzw. das Tor, ansonsten werden sie geschlossen.
E721 20 532014 - Rev. D
ÍNDICE
1 ADVERTENCIAS ............................................................................................................................................... 2
2 ESQUEMA Y COMPONENTES........................................................................................................................... 2
2.1 DESCRIPCIÓN DE LOS COMPONENTES ..................................................................................................................... 3
2.2 DESCRIPCIÓN DEL TABLERO DE BORNES J13 ..........................................................................................................................3
3 CARACTERÍSTICAS TÉCNICAS ......................................................................................................................... 3
4 CONEXIONES ELÉCTRICAS ............................................................................................................................. 4
4.1 FOTOCÉLULAS A BUS-2EASY ....................................................................................................................................... 5
4.1.1 DIRECCIÓN DE LAS FOTOCÉLULAS A BUS-2EASY ..........................................................................................................5
4.1.2 MEMORIZACIÓN DE LOS ACCESORIOS BUS-2EASY ......................................................................................................5
4.2 FOTOCÉLULAS TRADICIONALES ................................................................................................................................. 6
4.3 CONEXIONES ENTRADA SAFE ...................................................................................................................... 7
5 PROGRAMACIÓN .......................................................................................................................................... 8
5.1 PROGRAMACIÓN DE 1° NIVEL .................................................................................................................................. 8
5.2 PROGRAMACIÓN DE 2° NIVEL ................................................................................................................................ 10
6 MEMORIZACIÓN CODIFICACIÓN RADIO ..................................................................................................... 12
6.1 MEMORIZACIÓN DE LOS RADIOMANDOS DS.......................................................................................................... 12
6.2 MEMORIZACIÓN DE LOS RADIOMANDOS SLH ....................................................................................................... 13
6.3 MEMORIZACIÓN DE LOS RADIOMANDOS LC/RC (SÓLO PARA ALGUNOS MERCADOS) .......................................... 13
6.3.1 MEMORIZACIÓN REMOTA DE LOS TELEMANDOS LC/RC .............................................................................................13
6.4 PROCEDIMIENTO DE ELIMINACIÓN DE LOS TELEMANDOS ..................................................................................... 13
7 PUESTA EN FUNCIONAMIENTO ..................................................................................................................... 14
7.1 COMPROBACIÓN DE LOS LED .................................................................................................................................. 14
7.2 FUNCIONAMIENTO CON BATERÍA .............................................................................................................. 14
7.3 COLOCACIÓN DE LOS FINALES DE RECORRIDO ..................................................................................................... 15
7.4 CONFIGURACIONES MASTER / SLAVE ...................................................................................................................... 16
7.4.1 CABLEADOS MASTER/SLAVE ....................................................................................................................................... 16
7.4.2 PROCEDIMIENTO DE SETUP MASTER/SLAVE ................................................................................................................ 16
7.5 SETUP ....................................................................................................................................................................... 17
8 PRUEBA DEL AUTOMATISMO .................................................................................................................... 17
9 SEÑALACIÓN DE ALARMAS Y ERRORES ........................................................................................................ 17
9.1 ALARMAS ................................................................................................................................................................. 17
9.2 ERRORES ................................................................................................................................................................. 17
10 LÓGICAS DE FUNCIONAMIENTO ................................................................................................................ 18
DECLARACIÓN CE DE CONFORMIDAD
Fabricante: FAAC S.p.A.
Dirección: Via Calari, 10 - 40069 Zola Predosa BOLONIA - ITALIA
Declara que: el equipo electrynico E721
cumple con los requisitos esenciales de seguridad de las siguientes directivas CEE
ESPAÑOL
2006/95/CE Directiva Baja Tensiyn
2004/108/CE Directiva Compatibilidad Electromagnptica
Nota adicional:
Este producto se ha sometido a pruebas en una configuraciyn ttpica
homogpnea (todos los productos estin fabricados por FAAC S.p.A.).
Bolonia, 01-12-2011
El Administrador Delegado
A. Marcellan
ADVERTENCIAS
£Atenciyn! Para la seguridad de las personas es sumamente importante seguir atentamente estas instrucciones.
Una instalaciyn incorrecta o una utilizaciyn inadecuada del producto pueden causar graves daxos a las
personas.
Lea detenidamente las instrucciones antes de empezar la instalaciyn del producto y guirdelas para futuras consultas.
El stmbolo indica informaciyn importante para la seguridad de las personas y para la integridad del
automatismo.
El stmbolo llama la atenciyn sobre las notas de las caractertsticas y del funcionamiento del producto.
E721 1 532014 - Rev. D
E721
1 ADVERTENCIAS
Desconecte la alimentación eléctrica antes de realizar cualquier intervención en la instalación
electrónica (conexiones, mantenimiento).
Coloque encima del equipo un interruptor magnetotérmico diferencial con un umbral de inter-
vención adecuado.
2 ESQUEMA Y COMPONENTES
/ SAFE
/ SAFE
SENSOR
FINAL DE RECORRIDO
ESPAÑOL
Fig. 1
/ SAFE
/ SAFE
Para la conexiyn de
las fotocplulas y de los
dispositivos de seguridad,
remttase al pirrafo 4.2
230 V ~
115 V ~
=
CONTACTO
DE DESBLOQUEO
DEL MOTOR
(Bloquea el motor cuan-
do se acciona la mani-
= lla de desbloqueo del
motor)
Fig. 2
E721
E721 E721
E721
C720
C 72 C721
C 721
ESPAÑOL
Fig.
Fig. 4
OUT
Otros dispositivos
de seguridad
OUT
OUT
Otros dispositivos
de seguridad
Fig. 6
Otros dispositivos
de seguridad
Fig. 7 Fig. 10
E721 6 532014 - Rev. D
Conexión de un par de fotocplulas en cierre, Ning~n dispositivo de seguridad y parada conectado
un par en apertura y un par en apertura/cierre
Fig. 12
Fig. 11
Programando: 2° nivel o 1=00 (FAIL SAFE DESACTIVADO) Programando: 2° nivel o 1=00 (FAIL SAFE DESACTIVADO)
2° nivel SP=01 (ENT5ADA 4 = BO5DE DE SEGU5IDAD) 2° nivel Ob=02 (ENT5ADA =BO5DE DE SEGU5IDAD)
Otros dispositivos de
Otros dispositivos de seguridad
seguridad OPEN A
GND OPEN A
OPEN B / CLOSE GND
SAFE / STOP - SAFE / OPEN B / CLOSE
- FSW OP STOP
GND FSW OP
FSW CL GND
+24V FSW CL
+24V Fig. 14
Si no se utilizan dispositivos con contacto N.C. (Otros dispositivos de seguridad) la entrada SAFE deberá
puentearse con el -OUT con FAIL SAFE activado, o con el GND con FAIL SAFE desactivado.
E721 7 532014 - Rev. D
5 PROGRAMACIÓN La modificación de los parámetros de
programación es eficaz tan pronto como
Para programar el funcionamiento del automatismo es
se ejecuta, mientras que la memorización
necesario acceder a la modalidad “P5OG5AMACIÐN”. definitiva sólo tiene lugar cuando se sale
La programación se divide en dos partes: 1° NIVEL, 2° NIVEL. de la programación y se regresa a la
Normalmente en la pantalla se muestra visualización del estado de las entradas.
el estado del automatismo. Pulsando Si se quita la alimentación al equipo antes
el pulsador F o pulsando a la vez F y de regresar a la visualización del estado
+ se accede respectivamente a la de las entradas, todas las modificaciones
programación de 1° o de 2° nivel. Durante realizadas se perderán.
el funcionamiento con batería el display Se puede volver a la vista del estado de las
está apagado. Presione brevemente
la tecla + para visualizar el estado del entradas, y memorizar todos los parámetros
automatismo. modificados hasta aquel momento, desde
cualquier punto de la programación de 1° y
Para restablecer las configuraciones 2° nivel pulsando a la vez los pulsadores F y -.
predeterminadas basta con recargar la
configuración predeterminada deseada en el Cuando se encienda la tarjeta en la pantalla
primer paso de la programación de 1° nivel. LCD1 aparecerá durante unos segundos la
versión del software de la tarjeta con dos
5.1 PROGRAMACIÓN DE 1° NIVEL cifras separadas por un punto decimal.
Para acceder a la programación de 1° nivel es necesario pulsar el pulsador F.
Si se presiona y mantiene presionada la tecla F en el display aparece el nombre de la función.
Soltando el pulsador, la pantalla muestra el valor de la función, que puede modificarse con los pulsadores + y -.
Volviendo a pulsar F (y mantenipndola pulsada) la pantalla muestra el nombre de la función siguiente, etc.
Al llegar a la ~ltima función, la presión del pulsador F provoca la salida de la programación y la memorización de
los parimetros. La pantalla vuelve a mostrar el estado del automatismo.
PROGRAMACIÓN DE 1° NIVEL
Valor
Panta- predeter-
Función
lla
minado 1
VALOR PREDETERMINADO:
dF 1 Configura los parimetros con valores de DEFAULT.
1
CU Si al soltar el pulsador F aparece el valor CU significa que se ha seleccionado la
configuración estindar a travps de los pulsadores y la pantalla. Si desea mantener
esta programación, vuelva a pulsar el pulsador F , de lo contrario, pulse + y selec-
cione el default 1 .
CONFIGURACIÓN MASTER/SLAVE
Ct MA Configura la tarjeta en modo MASTER
MA
SL Configura la tarjeta en modo SLAVE
Configurando la tarjeta en modo SLAVE no se visualizarán los parámetros
LO-PA-Pb-Ph-Op (para funcionamiento Master/Slave véase el párrafo 7.4.)
LÓGICAS DE FUNCIONAMIENTO:
LO E Semiautomitica E
EP
ESPAÑOL
PROGRAMACIÓN DE 2° NIVEL
Valor
Panta-
Función predeter-
lla
minado 1
POTENCIA MÁXIMA EN EL MOMENTO DEL ARRANQUE:
bo El motor trabaja con la mixima potencia (ignorando el nivel de potencia seleccionado)
no
durante el momento del arranque.
Y = activo
no = excluido
PARPADEO PREVIO:
PF Permite seleccionar 5 tipos de parpadeo previo, con una duración de segundos.
no
no = ninguno parpadeo previo.
OC = parpadeo previo antes de cualquier movimiento.
CL = parpadeo previo antes de cualquier movimiento durante el cierre.
OP = parpadeo previo antes de cualquier movimiento durante la apertura.
PA = parpadeo previo sólo al final de la pausa
TIEMPO DE PARPADEO PREVIO (visible sólo si se ha seleccionado un parpadeo previo en
tP el menú anterior): 03
5egula el tiempo de parpadeo previo de 1 a 10 segundos en pasos de 1 segundo.
01 = parpadeo previo mtnimo
10 = parpadeo previo miximo
FOTOCÉLULAS EN CIERRE:
Ph Active la función si desea que las fotocplulas de cierre bloqueen el movimiento y lo inviertan
no
para liberarlo. Normalmente, con esta función excluida, la intervención de las fotocplulas
de cierre determina una inversión inmediata de la cancela.
Y = inversión para liberación
no = inversión inmediata durante la apertura
Parámetro no visualizado en modo SLAVE
FOTOCÉLULAS EN APERTURA:
oP Active la función si desea que las fotocplulas de apertura bloqueen el movimiento y lo no
inviertan durante el cierre. Normalmente, con esta función excluida, la intervención de las
fotocplulas de apertura determina la recuperación del movimiento durante su liberación.
Y = inversión inmediata durante el cierre
n o = recuperación del movimiento durante la liberación
ESPAÑOL
< (1) F
BUS 2EASY
< (2)
< OPEN A -
< GND
< OPEN B / CLOSE < SAFE
+
R
A
C
1
RADIO XF
R
2
IO
E
FC
FC
IO
O
< STOP / SAFE
W
R
D
O
R
A
P
R
< FSW OP
R
SETUP
< GND
< FSW CL
< +24
USB
BATTERY
RELEASE
Y
R
)
R
F
OUT
-L
E
S
S
E IN
TO
R M
K
K
K
T
-N
N
T EC
C
T
T RI
C
C
(P A
- +
A
LO
LA
LO
LO
M
R
P
M
B
<
<
<
<
<
<
<
<
<
Fig. 16
Los LED FCA y FCC representan los contactos NC del final Las entradas STOP (SAFE), FSW CL, FSW
de carrera integrado en la tarjeta que, si estin ocupados, OP, OPEN B configurada como SAFE son
se abren apagando el LED correspondiente: entradas de seguridad con contacto N.C.
(Normalmente Cerrado) y, por lo tanto,
los correspondientes diodos deben estar
Automatismo FCA
ENCENDIDOS en condición de automatismo
CE55ADO en reposo, y se apagarán cuando se ocupe
FCC FCC ocupado
el dispositivo conectado.
FCA FCA ocupado Las entradas OPEN A, OPEN B/CLOSE son
Automatismo ABIE5TO
entradas con contacto N.A. (Normalmente
FCC
Abierto) y, por lo tanto, los correspondientes
diodos deben estar APAGADOS en condición
Tab. 3 - Descripción LED POWER de automatismo en reposo, y se encenderán
cuando se ocupe el dispositivo conectado.
ESPAÑOL
ATENCIÓN
Para optimizar los consumos y salvaguardar la carga, durante el funcionamiento con baterta, con el automatismo parado
y el sistema en stand-by, el display LCD1, el diodo BUS 2easy y los diodos FCC y FCA estin apagados, mientras que el
diodo PO:E5 destella.
En esta fase se puede visualizar el estado del automatismo. Para ello es suficiente presionar brevemente la tecla + presente
en la tarjeta. Despups de haber presionado esta tecla, el display LCD1 muestra durante unos 2 segundos el estado del
automatismo, para luego apagarse otra vez. Sin embargo, durante un movimiento normal, todos los diodos de diagnóstico
y las sexalizaciones del display vuelven a ser coherentes con el estado del automatismo (vpase Fig. 16).
E721 14 532014 - Rev. D
7.3 COLOCACIÓN DE LOS FINALES DE RECORRIDO
Para colocar correctamente los imanes de final de carrera, es necesario que la central de control
esté instalada y conectada correctamente con todos los accesorios de control y seguridad.
El operador dispone de un sensor magnptico de final de carrera, directamente integrado en la tarjeta electrónica de control.
La parada de la cancela, al abrirse o cerrarse, se produce en el momento en el que el imin polarizado, fijado en
la parte superior de la cremallera, activa el sensor.
A
C
R O1
2
FC
FC
IO
I
Cuando el LED que corresponde al final de carrera FCA presente en la tarjeta se apaga,
R
A
E
R
ftjelo con los tornillos correspondientes.
4. Ponga manualmente la cancela en posición de cierre dejando 40 mm con respecto
al tope mecinico de final de carrera.
5. Coloque en la cremallera el imin con la parte CUADRADA en la dirección del motor.
Cuando el LED que corresponde al final de carrera FCC presente en la tarjeta se apaga,
ftjelo con los tornillos correspondientes.
A
C
R O1
2
FC
FC
IO
6. Compruebe que al final de la maniobra, tanto en apertura como en cierre, el LED del
I
D
R
A
final de carrera correspondiente se apague correctamente y, si es necesario, aporte las
E
R
modificaciones oportunas a la posición de los imanes de final de carrera.
Para evitar que se produzcan daños en el operador y/o interrupciones del
funcionamiento del automatismo es necesario dejar unos 40 mm de distancia
de los topes mecánicos de final de carrera.
Para un funcionamiento
correcto del operador.
el imán que representa
la parte REDONDA debe
utilizarse como final de
carrera de APERTURA y
el imán con la parte
CUADRADA debe
utilizarse como final
de carrera de CIERRE
(VÉASE FIG. 17)
Si el equipo está
configurado MASTER/
SLAVE, los imanes de
los finales de carrera
deben estar instalados
como se muestra en la
Fig. 18.
ESPAÑOL
Fig. 17
MASTER/SLAVE
Fig. 18
Evite cualquier tipo de conexión y cableado en la regleta de bornes J13 de la central SLAVE
La conexión BUS entre las dos tarjetas deberá ser POLARIZADA respetando la secuencia de los
polos de la regleta de bornes J12 (POLO (1) - POLO (2)) - (véase la Fig. 19).
Al configurar una central como SLAVE se fuerzan los valores de algunos parámetros de
programación que ya no se visualizan en el menú (LO-PA-Pb-Ph-Op). Si se vuelve a poner
la tarjeta en modo MASTER, estos valores, forzados anteriormente, se mantienen dentro de la
programación.
7.4.1 CABLEADOS MASTER/SLAVE
(1) (1)
BUS 2 EASY BUS 2 EASY
(2) (2)
Evite cualquier tipo de
conexión y cableado
en la regleta de
bornes J1 de la
central SLAVE
1. Desbloquee ambas hojas, colóquelas a mitad del recorrido y bloqupelas de nuevo (vpase el procedimiento n° 1
Pirrafo 7.5 SETUP).
2. Mantenga presionado el pulsador SETUP de la tarjeta MASTE5 hasta que la cancela MASTE5 empiece el movimiento.
. Ahora la cancela MASTE5 realiza un procedimiento completo de SETUP (vpase pirrafo 7.5 SETUP).
4. Una vez terminado correctamente el SETUP de la tarjeta MASTE5 empieza el procedimiento completo de SETUP
de la tarjeta SLAVE (vpase pirrafo 7.5 SETUP).
5. Finalizado tambipn este procedimiento, la MASTE5 comprueba la posición de la hoja SLAVE y la coloca en la
misma posición (abierto o cerrado) que la hoja MASTE5.
6. Procedimiento completado.
CE55ADO abre la cancela abre la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto ning~n efecto
parcialmente (OPEN inhibido) (OPEN inhibido) (OPEN inhibido)
ABIE5TO vuelve a cerrar vuelve a cerrar vuelve a cerrar ning~n efecto ning~n efecto ning~n efecto ning~n efecto
la cancela (1) la cancela la cancela (OPEN/CLOSE inhibidos) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
CE55ADO abre la cancela abre la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto ning~n efecto
parcialmente (OPEN inhibido) (OPEN inhibido) (OPEN inhibido)
ABIERTO vuelve a cerrar vuelve a cerrar vuelve a cerrar ning~n efecto ning~n efecto ning~n efecto ning~n efecto
la cancela (1) la cancela la cancela (OPEN/CLOSE inhibidos) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
recarga el tiempo en recarga el tiempo vuelve a cerrar bloquea el recarga el tiempo recarga el tiempo en
ABIERTO EN PAUSA pausa (1) en pausa B la cancela funcionamiento ning~n efecto en pausa pausa
(CLOSE inhibido) (CLOSE inhibido)
BLOQUEADO cierra la cancela cierra la cancela cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (OPEN inhibido) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
recarga el tiempo en recarga el tiempo vuelve a cerrar bloquea el bloquea y cuando se recarga el tiempo en
ABIERTO EN PAUSA ning~n efecto pausa
pausa (1) en pausa B la cancela funcionamiento libera cierra ripido (CLOSE inhibido)
BLOQUEADO cierra la cancela cierra la cancela cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (OPEN inhibido) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
(1) Durante el ciclo de apertura parcial, un impulso de OPEN A provoca la apertura total
E721 18 532014 - Rev. D
LÐGICA “AP” IMPULSOS
ESTADO AUTOMATISMO OPEN A OPEN B CLOSE STOP FS: OP FSW CL FSW CL/OP
abre y vuelve a cerrar abre la cancela parcial- ning~n efecto ning~n efecto ning~n efecto
CERRADO despups del tiempo de mente y cierra despups del ning~n efecto (OPEN inhibido) (OPEN inhibido) ning~n efecto (OPEN inhibido)
pausa tiempo de pausa B
BLOQUEADO cierra la cancela cierra la cancela cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (OPEN inhibido) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
recarga el tiempo recarga el tiempo en vuelve a cerrar la cancela bloquea el recarga el tiempo recarga el tiempo en
ABIERTO EN PAUSA en pausa (1) pausa funcionamiento ning~n efecto en pausa pausa
(CLOSE inhibido) (CLOSE inhibido)
BLOQUEADO cierra la cancela cierra la cancela cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (OPEN inhibido) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
ABIERTO EN PAUSA vuelve a cerrar vuelve a cerrar la cancela vuelve a cerrar la cancela bloquea el ning~n efecto bloquea y cuando se bloquea y cuando se
la cancela (1) funcionamiento libera cierra ripido libera cierra
BLOQUEADO cierra la cancela cierra la cancela cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
ESPAÑOL
(OPEN/CLOSE inhibidos) (OPEN inhibido) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
bloquea el bloquea el vuelve a cerrar bloquea el contin~a abriendo y bloquea y cuando se libera abre
EN APERTURA funcionamiento (1) funcionamiento la cancela funcionamiento vpase prog. 2° niv. vuelve a cerrar ripido
y, al finalizar, cierra ripido (OPEN
bloquea - memoriza CLOSE)
ABIERTO EN PAUSA vuelve a cerrar vuelve a cerrar vuelve a cerrar bloquea el ning~n efecto bloquea y cuando se bloquea y cuando se
la cancela (1) la cancela la cancela funcionamiento libera cierra ripido libera cierra ripido
(1) Durante el ciclo de apertura parcial, un impulso de OPEN A provoca la apertura total
E721 19 532014 - Rev. D
LÐGICA “SA” IMPULSOS
ESTADO AUTOMATISMO OPEN A OPEN B CLOSE STOP FS: OP FSW CL FSW CL/OP
abre y vuelve a cerrar abre la cancela parcial- ning~n efecto ning~n efecto ning~n efecto
CERRADO despups del tiempo de mente y cierra despups del ning~n efecto (OPEN inhibido) (OPEN inhibido) ning~n efecto (OPEN inhibido)
pausa tiempo de pausa B
vuelve a cerrar la cancela vuelve a cerrar vuelve a cerrar bloquea el recarga el tiempo recarga el tiempo en
ABIERTO EN PAUSA (1) la cancela la cancela funcionamiento ning~n efecto en pausa pausa
(CLOSE inhibido) (CLOSE inhibido)
BLOQUEADO cierra la cancela cierra la cancela cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (OPEN inhibido) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
CERRADO abre la cancela / ning~n efecto ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN inhibido) (OPEN inhibido) (OPEN inhibido)
ABIERTO ning~n efecto / cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
BLOQUEADO abre la cancela / cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (OPEN inhibido) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
CERRADO abre la cancela / ning~n efecto ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN inhibido) (OPEN inhibido) (OPEN inhibido)
ABIERTO ning~n efecto / cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
BLOQUEADO abre la cancela / cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (OPEN inhibido) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
ESPAÑOL
CERRADO abre la cancela / ning~n efecto ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN inhibido) (OPEN inhibido) (OPEN inhibido)
EN APERTURA ning~n efecto / cierra la cancela bloquea el vpase prog. 2° niv. ning~n efecto bloquea y cuando se
funcionamiento libera vpase prog. 2° niv.
ABIERTO ning~n efecto / cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
EN CIERRE abre la cancela / ning~n efecto bloquea el ning~n efecto bloquea el bloquea el
funcionamiento funcionamiento funcionamiento
BLOQUEADO abre la cancela / cierra la cancela ning~n efecto ning~n efecto ning~n efecto ning~n efecto
(OPEN/CLOSE inhibidos) (OPEN inhibido) (CLOSE inhibido) (OPEN/CLOSE inhibidos)
(1) Durante el ciclo de apertura parcial, un impulso de OPEN A provoca la apertura total
(2) Cuando se enciende, la tarjeta comprueba las entradas y si un accionamiento de OPEN A o B esti activo abre la hoja o
la cancela, de lo contrario, cierra.
E721 20 532014 - Rev. D
INDEX
1 WAARSCHUWINGEN ....................................................................................................................................... 2
2 LAY-OUT EN COMPONENTEN .......................................................................................................................... 2
2.1 BESCHRIJVING COMPONENTEN ................................................................................................................................ 3
2.2 BESCHRIJVING KLEMMENBORD J13 .......................................................................................................................... 3
3 TECHNISCHE EIGENSCHAPPEN ........................................................................................................................ 3
4 ELEKTRISCHE AANSLUITINGEN ......................................................................................................................... 4
4.1 BUS-2EASY-FOTOCELLEN ............................................................................................................................................ 5
4.1.1 ADRESSERING BUS-2EASY-FOTOCELLEN ........................................................................................................................5
4.1.2 GEHEUGENOPSLAG BUS-2EASY-ACCESSOIRES ..............................................................................................................5
4.2 TRADITIONELE FOTOCELLEN ...................................................................................................................................... 6
4.3 AANSLUITINGEN SAFE-INGANG ................................................................................................................... 7
5 PROGRAMMERING ........................................................................................................................................ 8
5.1 PROGRAMMERING NIVEAU 1 ................................................................................................................................... 8
5.2 PROGRAMMERING NIVEAU 2 .................................................................................................................................. 10
6 GEHEUGENOPSLAG RADIOCODERING ......................................................................................................... 12
6.1 GEHEUGENOPSLAG VAN DE DS-RADIOBESTURINGEN .............................................................................................. 12
6.2 GEHEUGENOPSLAG VAN DE SLH-RADIOBESTURINGEN ........................................................................................... 13
6.3 GEHEUGENOPSLAG VAN DE LC/RC-RADIOBESTURINGEN (ALLEEN BESCHIKBAAR VOOR SOMMIGE LANDEN) ........ 13
6.3.1 GEHEUGENOPSLAG OP AFSTAND VAN DE LC/RC-RADIOBESTURINGEN .......................................................................13
6.4 RADIOBESTURINGEN UIT HET GEHEUGEN WISSEN ................................................................................................... 13
7 INBEDRIJFSTELLING ..................................................................................................................................... 14
7.1 CONTROLE VAN DE LEDs .......................................................................................................................................... 14
7.2 WERKING OP BATTERIJEN ......................................................................................................................... 14
7.3 POSITIONERING VAN DE EINDAANSLAG ................................................................................................................. 15
7.4 CONFIGURATIES MASTER / SLAVE ............................................................................................................................ 16
7.4.1 BEKABELING MASTER/SLAVE ....................................................................................................................................... 16
7.4.2 SET-UP-PROCEDURE MASTER/SLAVE ............................................................................................................................ 16
7.5 SETUP ....................................................................................................................................................................... 17
8 HET AUTOMATISCHE SYSTEEM TESTEN ........................................................................................................... 17
9 SIGNALERING VAN ALARMMELDINGEN EN FOUTEN ...................................................................................... 17
9.1 ALARMMELDINGEN.................................................................................................................................................. 17
9.2 FOUTEN ................................................................................................................................................................... 17
10 BEDRIJFSLOGICA'S .................................................................................................................................... 18
CE-VERKLARING VAN OVEREENSTEMMING
Fabrikant: FAAC S.p.A.
Adres: Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALIÊ
verklaart dat: De elektronische apparatuur E721
in overeenstemming is met de belangrijkste veiligheidseisen van de volgende
EEG-richtlijnen:
2006/95/EG Laagspanningsrichtlijn
2004/108/EG 5ichtlijn Elektromagnetische compatibiliteit
Extra opmerking:
Dit product is getest in een standaard, homogene configuratie
(gelijk voor alle producten van FAAC S.p.A.).
Bologna, 01-12-2011
De President-directeur
A.Marcellan
NEDERLANDS
WAARSCHUWINGEN
Let op! Het is belangrijk voor de veiligheid dat deze hele instructie zorgvuldig wordt opgevolgd.
Een onjuiste installatie of foutief gebruik van het product kan ernstig persoonlijk letsel veroorzaken.
Lees de instructies aandachtig door alvorens te beginnen met de installatie van het product en bewaar ze voor latere
raadpleging.
Het symbool markeert belangrijke informatie voor de persoonlijke veiligheid en de integriteit van het
automatische systeem.
Het symbool vestigt de aandacht op informatie met betrekking tot de eigenschappen of de werking
van het product.
E721 1 532014 - Rev. D
E721
1 WAARSCHUWINGEN
Alvorens werkzaamheden aan de elektronische apparatuur te verrichten (aansluitingen, onderhoud)
moet altijd eerst de elektrische voeding worden weggenomen.
Breng bovenstrooms van het systeem een thermomagnetische differentieelschakelaar aan met
een juiste inschakellimiet.
2 LAY-OUT EN COMPONENTEN
/ SAFE
/ SAFE
SENSOR
EINDAANSLAG
Fig. 1
NEDERLANDS
/ SAFE
/ SAFE
230 V ~
115 V ~
=
CONTACT
MOTORONTGRENDELING
(Blokkeert de motor
wanneer de hendel van
de motorontgrendeling
= wordt bewogen)
Fig. 2
E721
E721 E721
E721
C720
C 72 C721
C 721
Fig.
Fig. 4
Uit (knippert
Kortsluiting in BUS-2EAS<-lijn
elke 2,5 sec.)
-Lijn BUS-2EAS< gedeactiveerd (geeft geen
voeding)
Uit - :erking op batterijen.
- Besturingseenheid als SLAVE
geprogrammeerd
OUT
Overige
beveiligingen
OUT
OUT
Overige
beveiligingen
Fig. 6
Overige
beveiligingen
NEDERLANDS
Fig. 7 Fig. 10
E721 6 532014 - Rev. D
Aansluiting van ppn paar fotocellen bij sluiting, ppn paar Aansluiting zonder veiligheids- en stopvoorzieningen
bij opening en ppn paar bij opening/sluiting
Fig. 12
Fig. 11
Instellen: 2e niveauo 1=01 (FAIL SAFE GEACTIVEE5D) Instellen: 2e niveau o 1=01 (FAIL SAFE GEACTIVEE5D)
2e niveau SP=01 (INGANG 4 = VEILIGHEIDSLIJST) 2e niveau Ob=02 (INGANG = VEILIGHEIDSLIJST)
Andere veiligheidsvoorzieningen
Andere veiligheidsvoorzieningen OPEN A OPEN A
GND GND
OPEN B / CLOSE - OUT SAFE / OPEN B / CLOSE
- OUT SAFE / STOP STOP
FSW OP FSW OP
GND GND
FSW CL FSW CL
+24V +24V Fig. 1
Als de veiligheidsinrichting Fail-Safe wordt gedeactiveerd (parameter kan worden geconfigureerd in het
2e programmeerniveau), moet het negatief dat voor het beheer van de SAFE-ingang wordt gebruikt -
zijn (zie Fig. 14).
Aansluiting van een veiligheidsinrichting (andere veiligheidsinrichtingen) op de SAFE-ingang met functie FAIL-SAFE gedeactiveerd
Instellen: 2e niveauo 1=00 (FAIL SAFE GEDEACTIVEE5D) Instellen: 2e niveauo 1=00 (FAIL SAFE GEDEACTIVEE5D)
2e niveau SP=01 (INGANG 4 = VEILIGHEIDSLIJST) 2e niveau Ob=02 (INGANG =VEILIGHEIDSLIJST)
Andere veiligheidsvoorzieningen
OPEN A
Andere veiligheidsvoorzieningen OPEN A
GND
NEDERLANDS
PROGRAMMERING NIVEAU 1
PAUZETIJD A:
PA De pauzetijd ten opzichte van een commando voor VOLLEDIGE opening. Heeft alleen effect
20
als een automatische bedrijfslogica is geselecteerd. Instelbaar van 0 tot 59 sec. in stappen
van een seconde.
Vervolgens verandert de weergave in minuten en tienden van seconden (gescheiden door een punt)
en is de tijd instelbaar in stappen van 10 seconden, tot de maximumwaarde van 9.5 minuten.
Bijv.: als het scherm 2.5 aangeeft, correspondeert de pauzetijd met 2 min. en 50 sec.
Parameter niet weergegeven in SLAVE-modus
Indien de poort, tijdens het openen of het sluiten, tegen een obstakel botst, zorgt de virtuele
encoder voor de omkering van de beweging. Een tweede obstakel dat in dezelfde richting
wordt waargenomen, veroorzaakt de uitschakeling van de motor. In beide gevallen wordt er
een alarmmelding gegenereerd (zie par. alarmmeldingen)
De gevoeligheid van de virtuele encoder moet worden ingesteld door de wachttijd, voordat
de kaart het commando geeft tot omkering van de beweging, in te stellen van minimaal
0 sec tot maximaal 10 sec in stappen van een seconde.
00 = maximale gevoeligheid
10 = minimale gevoeligheid
E721 10 532014 - Rev. D
Display Functie Default 1
GEDEELTELIJKE OPENING:
PO Het is mogelijk de omvang van de gedeeltelijke opening van de vleugel in te stellen als 50
percentage van het totale loopvlak van de poort.
Instelbaar van 0 tot 99 %. in stappen van 1%.
00 = geen gedeeltelijke opening
01 = minimale gedeeltelijke opening
99 = maximale gedeeltelijke opening
WERKTIJD (time-out):
t Het is handig om een hogere waarde in te stellen dan de tijd die de poort nodig heeft om 2.0
volledig te openen en te sluiten.
Instelbaar van 0 tot 59 sec. in stappen van 1 seconde. Vervolgens verandert de weergave
in minuten en tienden van seconden (gescheiden door een punt) en is de tijd instelbaar in
stappen van 10 seconden, tot de maximumwaarde van 9.5 minuten.
Bijv.: als het scherm 2.5 aangeeft, correspondeert de pauzetijd met 2 min. en 50 sec.
In geval van een installatie met een MASTER/SLAVE-configuratie moet een WER
KINGSTIJD op de MASTER-besturingseenheid worden ingesteld die met de
bewegingstijd van beide vleugels rekening houdt.
OUT 1:
o1 Hiermee kan de uitgang OUT (open collector N.A.) worden geactiveerd in een van de 00
volgende funties:
00 = Altijd actief (geeft spanning 24V= met maximale absorptie van 100 mA)
01 = FAIL-SAFE (Controleer of de aangesloten traditionele fotocellen goed werken)
02 = CONT5OLELAMPJE (gedoofd als de poort dicht is, brandt tijdens het openen open/pauze, knippert
tijdens het sluiten)
03 = VE5LICHTING (zie volgende functie)
04 = ALA5M werkt op ACCU
05 = poort OPEN of in PAUZE
06 = poort DICHT
07 = poort in BE:EGING
08 = poort gaat OPEN
09 = poort gaat DICHT
1 0 = beveiliging ACTIEF
1 1 = tijdgeschakelde uitgang kan worden geactiveerd vanaf het tweede radiokanaal (zie
volgende functie)
1 2 = uitgang kan worden geactiveerd vanaf het tweede radiokanaal (werking stap-voor-stap)
t1 UITSCHAKELTIJD OUT 1 (alleen zichtbaar als bij de vorige stap het item 03 of 11 is geselecteerd):
Hiermee kan de uitschakeltijd van de uitgang OUT worden ingesteld indien een tijdswerking
02
is geselecteerd (zoals bijv. 03 of 11 ) van 1 tot 99 minuten, in stappen van 1 minuut
OPEN B / CLOSE / VEILIGHEIDSLIJST:
Ob Het is mogelijk om het gebruik van de ingang OPEN B te selecteren als gedeeltelijke opening 00
, commando CLOSE of VEILIGHEIDSLIJST.
00 = OPEN B
01 = CLOSE
02 = VEILIGHEIDSLIJST (NG-contact)
Indien er een bedrijfslogica is geselecteerd dat gebruik maakt van het
commando CLOSE (logica b, bC, C) dan is deze functie vooraf ingesteld als 01
en kan niet meer worden gewijzigd.
OPEN B / VEILIGHEIDSLIJST
SP Het is mogelijk om het gebruik van de ingang STOP te selecteren als STOP of VEILIGHEIDSLIJST. 00
00 = STOP
01 = VEILIGHEIDSLIJST (NG-contact)
GEDEELTELIJKE OMKERING:
IP Het type omkering (volledig of gedeeltelijk) vanwege een obstakel of na ingrijpen door de no
veiligheidslijst is instelbaar.
Y = Activering gedeeltelijke omkering. In geval van een obstakel of door activering van
NEDERLANDS
kanalen bestaan. Er kunnen maximaal 256 5. De bijbehorende led zal gedurende 1 seconde bran-
radiocoderingen, verdeeld over OPEN A en den en daarna doven, wat aangeeft dat de gegevens
OPEN B, worden ingevoerd zijn opgeslagen.
Om verschillende coderingssystemen op 6. Om meer en andere codes toe te voegen dan die
hetzelfde kanaal te gebruiken, moet het reeds zijn opgeslagen, moet de procedure vanaf punt
zelflerende proces van elk systeem worden 1 worden herhaald.
beëindigd en moet vervolgens de procedure
voor het andere worden herhaald.
Sluit geen enkele radiovoorziening op de als
SLAVE geconfigureerde apparatuur aan.
twee maal kort achter elkaar in. De 2 leds zullen gedurende 2 sec. branden en daarna
doven (wissen voltooid).
Het automatische systeem zal de poort
Laat de beiden toetsen weer los.
openen. Controleer of het automatische
systeem niet wordt gehinderd door obsta- Deze handeling kan NIET ongedaan worden
kels in de vorm van personen of voorwer- gemaakt. Alle codes van de radiobesturin-
pen. gen die zowel als OPEN A of OPEN B/CLOSE
in het geheugen zijn opgeslagen, zullen
worden gewist.
< (1) F
BUS 2EASY
< (2)
< OPEN A -
< GND
< OPEN B / CLOSE < SAFE
+
R
A
C
1
RADIO XF
R
2
IO
E
FC
FC
IO
O
< STOP / SAFE
W
R
D
O
R
A
P
R
< FSW OP
R
SETUP
< GND
< FSW CL
< +24
USB
BATTERY
RELEASE
Y
R
)
R
F
OUT
-L
E
S
S
E IN
TO
R M
K
K
K
T
-N
N
T EC
C
T
T RI
C
C
(P A
- +
A
LO
LA
LO
LO
M
R
P
M
B
<
<
<
<
<
<
<
<
<
Fig. 16
De leds FCA en FCC vertegenwoordigen de NG-contacten De ingangen STOP (SAFE), FSW CL, FSW OP,
OPEN B geconfigureerd als SAFE zijn ingangen
van de gewntegreerde eindaanslag op de kaart. :anneer
voor veiligheidsinrichtingen met NG-contact
ze zijn geactiveerd, openen ze, waardoor de bijbehorende (normaliter gesloten), dus als het automatisch
led dooft. systeem in de ruststand staat moeten de
bijbehorende leds BRANDEN; ze doven
Automatisch systeem FCA wanneer de aangesloten inrichting wordt
DICHT FCC FCC actief
ingeschakeld.
De ingangen OPEN A, OPEN B/CLOSE zijn
Automatisch systeem FCA FCA actief ingangen met NO-contact (normaliter
open), dus als het automatisch systeem in de
OPEN FCC ruststand staat moeten de bijbehorende leds
GEDOOFD zijn, ze gaan branden wanneer de
Tab. 3 - Beschrijving POWER-leds aangesloten inrichting wordt ingeschakeld.
In geval van als SLAVE geprogrammeerde
Brandt Netvoeding aanwezig. apparatuur moeten de bijbehorende leds
op klemmenbord J13 gedoofd zijn.
Knippert Accuvoeding. Als de led ERROR knippert, betekent dit dat
er een alarmmelding actief is (een situatie
die geen afbreuk doet aan de werking van
Uit Kaart uitgeschakeld.
de poort).
A
C
R O1
2
led op de kaart die bij de eindaanslag FCA hoort dooft, moet de magneet met de bijbehorende
FC
FC
IO
I
D
D
schroeven worden bevestigd.
R
A
E
R
. Breng de poort handmatig in de gesloten positie tot op 40 mm vanaf de mechanische
eindaanslag.
4. Schuif de magneet met het VIERKANT over de tandheugel in de richting van de motor. Zodra
de led op de kaart die bij de eindaanslag FCC hoort dooft, moet de magneet met de
bijbehorende schroeven worden bevestigd.
A
C
R O1
2
5. Controleer of aan het einde van de beweging, zowel in de geopende als in de gesloten
FC
FC
IO
I
D
R
A
positie, de led van de betreffende eindaanslag op de juiste wijze dooft en wijzig indien nodig
E
R
de positie van de eindaanslagmagneten.
Om schade aan de aandrijving en/of onderbrekingen van de werking van het
automatische systeem te voorkomen, moet er een afstand van circa 40 mm
vanaf de mechanische eindaanslagstops worden overgelaten.
Fig. 17
NEDERLANDS
MASTER/SLAVE
Fig. 18
De BUS-aansluiting tussen de twee kaarten moet GEPOLARISEERD zijn ten opzichte van de volgorde
van de polen van klemmenbord J12 (POOL (1) - POOL (2)) - (zie Fig. 19).
Als een besturingseenheid als SLAVE wordt geconfigureerd, worden de waarden van een aantal
programmeerparameters die niet meer in het menu zijn weergegeven, geforceerd (LO-PA-Pb-
Ph-Op). Als de kaart weer in de MASTER-modus wordt gebracht, worden deze eerder geforceerde
waarden in de programmering gehandhaafd.
7.4.1 BEKABELING MASTER/SLAVE
(1) (1)
BUS 2 EASY BUS 2 EASY
(2) (2)
Het SET-UP-verzoek, gesignaleerd door het knipperen van de code S0 op het display, kan op
zowel de MASTER- als de SLAVE-besturingseenheid verschijnen. In het tweede geval verschijnt op
de MASTER-besturingseenheid foutmelding 91 . In elk geval kan een SET-UP-procedure uitsluitend
vanaf de MASTER-besturingseenheid worden gestart.
1. Ontgrendel beide vleugels, zet ze half open en vergrendel ze weer (zie procedure n. 1 par. 7.5 SET-UP)
2. Houd de SET-UP-toets van de MASTE5-kaart ingedrukt tot de MASTE5-poort begint te bewegen.
. De MASTE5-poort voert nu een volledige SET-UP-procedure uit (zie par. 7.5 SET-UP)
4. Als de SET-UP-procedure van de MASTE5-kaart eenmaal correct is uitgevoerd, begint de volledige SET-UP-procedure
NEDERLANDS
Als de hierboven beschreven SET-UP-procedure niet volledig of verkeerd wordt uitgevoerd, moet
hij helemaal worden herhaald vanaf punt 1.
DICHT opent de poort opent de poort gedeeltelijk geen effect geen effect geen effect geen effect geen effect
(OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
OPEN sluit de poort weer (1) sluit de poort weer sluit de poort weer geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
GEBLOKKEE5D sluit de poort sluit de poort sluit de poort geen effect geen effect geen effect geen effect (OPEN blok-
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) keert - slaat CLOSE op)
DICHT opent de poort opent de poort gedeeltelijk geen effect geen effect geen effect geen effect geen effect
(OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
OPEN sluit de poort weer (1) sluit de poort weer sluit de poort weer geen effect geen effect Geen effect geen effect
(OPEN/CLOSE onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
DICHT opent en sluit weer na de opent de poort gedeeltelijk geen effect geen effect geen effect geen effect geen effect
pauzetijd en sluit na pauzetijd B (OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
GEOPEND IN PAUZE herlaad de pauzetijd (1) herlaad de pauzetijd B sluit de poort weer blokkeert de werking geen effect herlaad de pauzetijd herlaad de pauzetijd
(CLOSE onderdrukt) (CLOSE onderdrukt)
GEBLOKKEERD sluit de poort sluit de poort sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
DICHT opent en sluit weer na de opent de poort gedeeltelijk geen effect geen effect geen effect geen effect geen effect
pauzetijd en sluit na pauzetijd B (OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
GAAT OPEN geen effect (1) geen effect sluit de poort weer blokkeert de werking zie prog. niveau 2 gaat verder met openen disactivering
en sluit direct weer (slaat CLOSE op)
GEOPEND IN PAUZE herlaad de pauzetijd (1) herlaad de pauzetijd B sluit de poort weer blokkeert de werking geen effect blokkeert en sluit bij herlaad de pauzetijd
disactivering direct (CLOSE onderdrukt)
GEBLOKKEERD sluit de poort sluit de poort sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
(1) Tijdens de gedeeltelijke openingscyclus zorgt een impuls OPEN A voor de totale opening
E721 18 532014 - Rev. D
LOGICA “AP” IMPULSEN
STATUS AUTOMATISCH OPEN A OPEN B CLOSE STOP FS: OP FSW CL FSW CL/OP
S<STEEM
DICHT opent en sluit weer na de opent de poort gedeeltelijk geen effect geen effect geen effect geen effect geen effect
pauzetijd en sluit na pauzetijd B (OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
blokkeert en opent bij
GAAT OPEN blokkeert de werking (1) blokkeert de werking sluit de poort weer blokkeert de werking zie prog. niveau 2 geen effect disactivering (OPEN blok-
keert - slaat CLOSE op)
GEOPEND IN PAUZE blokkeert de werking (1) blokkeert de werking sluit de poort weer blokkeert de werking geen effect herlaad de pauzetijd herlaad de pauzetijd
(CLOSE onderdrukt) (CLOSE onderdrukt)
GAAT DICHT opent de poort weer opent de poort weer geen effect blokkeert de werking geen effect keert om in opening (zie disblacti
okkeert en opent bij
vering (OPEN blok-
prog. niveau 2) keert - slaat CLOSE op)
GEBLOKKEERD sluit de poort sluit de poort sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
DICHT opent en sluit weer na de opent de poort gedeeltelijk geen effect geen effect geen effect geen effect geen effect
pauzetijd en sluit na pauzetijd B (OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
blokkeert en opent bij
GAAT OPEN geen effect (1) geen effect sluit de poort weer blokkeert de werking keert om in sluiting geen effect disactivering
(slaat CLOSE op)
GEOPEND IN PAUZE herlaad de pauzetijd (1) herlaad de pauzetijd sluit de poort weer blokkeert de werking geen effect herlaad de pauzetijd herlaad de pauzetijd
(CLOSE onderdrukt) (CLOSE onderdrukt)
GEBLOKKEERD sluit de poort sluit de poort sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
DICHT opent en sluit weer na de opent de poort gedeeltelijk geen effect geen effect geen effect geen effect geen effect
pauzetijd en sluit na pauzetijd B (OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
GEOPEND IN PAUZE sluit de poort weer (1) sluit de poort weer sluit de poort weer blokkeert de werking geen effect blokkeert en sluit bij blokkeert en sluit bij
disactivering direct disactivering
keert om in opening (zie blokkeert en opent bij
GAAT DICHT opent de poort weer opent de poort weer geen effect blokkeert de werking geen effect prog. niveau 2) en sluit aan disactivering en sluit aan
het einde direct het einde direct
GEBLOKKEERD sluit de poort sluit de poort sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
DICHT opent en sluit weer na de opent de poort gedeeltelijk geen effect geen effect geen effect geen effect geen effect
pauzetijd en sluit na pauzetijd B (OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
GEOPEND IN PAUZE sluit de poort weer (1) sluit de poort weer sluit de poort weer blokkeert de werking geen effect blokkeert en sluit bij blokkeert en sluit bij
disactivering direct disactivering direct
DICHT opent en sluit weer na de Opent de poort gedeelte- geen effect geen effect geen effect geen effect geen effect
pauzetijd lijk en sluit na pauzetijd B (OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
blokkeert en opent bij
GAAT OPEN geen effect (1) geen effect sluit de poort weer blokkeert de werking zie prog. niveau 2 geen effect disactivering
(slaat CLOSE op)
GEOPEND IN PAUZE sluit de poort weer (1) sluit de poort weer sluit de poort weer blokkeert de werking geen effect herlaad de pauzetijd herlaad de pauzetijd
(CLOSE onderdrukt) (CLOSE onderdrukt)
GEBLOKKEERD sluit de poort sluit de poort sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
DICHT opent de poort / geen effect geen effect geen effect geen effect geen effect
(OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
blokkeert en opent
GAAT OPEN geen effect / sluit de poort blokkeert de werking zie prog. niveau 2 geen effect bij disactivering (slaat
OPEN/CLOSE op)
OPEN geen effect / sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
GEBLOKKEERD opent de poort / sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
DICHT opent de poort / geen effect geen effect geen effect geen effect geen effect
(OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
blokkeert en opent
GAAT OPEN geen effect / sluit de poort blokkeert de werking zie prog. niveau 2 geen effect bij disactivering (slaat
OPEN/CLOSE op)
OPEN geen effect / sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
GEBLOKKEERD opent de poort / sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
DICHT opent de poort / geen effect geen effect geen effect geen effect geen effect
(OPEN onderdrukt) (OPEN onderdrukt) (OPEN onderdrukt)
GAAT OPEN geen effect / sluit de poort blokkeert de werking zie prog. niveau 2 geen effect blokkeert en bij disactive-
ring, zie prog. niveau 2
NEDERLANDS
OPEN geen effect / sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
GAAT DICHT opent de poort / geen effect blokkeert de werking geen effect blokkeert de werking blokkeert de werking
GEBLOKKEERD opent de poort / sluit de poort geen effect geen effect geen effect geen effect
(OPEN/CLOSE onderdrukt) (OPEN onderdrukt) (CLOSE onderdrukt) (OPEN/CLOSE onderdrukt)
(1) Tijdens de gedeeltelijke openingscyclus zorgt een impuls OPEN A voor de totale opening
(2) Bij inschakeling controleert de kaart de ingangen en als een commando OPEN A of B actief is, wordt de vleugel of poort geopend,
of anders gesloten.
E721 20 532014 - Rev. D
QRWHQRWHVQRWHQRWDVDQPHUNXQJRSPHUNLQJHQ
SEDE - HEADQUARTERS
FAAC S.p.A.
Via Calari, 10
40069 Zola Predosa (BO) - ITALY
Tel. +39 051 61724 - Fax +39 051 758518
www.faac.it - www.faacgroup.com
ASSISTENZA IN ITALIA
SEDE
MILANO PADOVA
tel. +39 051 6172501
tel +39 02 66011163 tel +39 049 8700541
www.faac.it/ita/assistenza
filiale.milano@faacgroup.com filiale.padova@faacgroup.com
SUBSIDIARIES