Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
DATA SHEET N
OGGETTO
D'ALESSANDRO
TERMOMECCANICA
A*
DS-107
DATA
REV.
02/03/2015
B
e
N1
N5 N4
T1 T2 T3 T4
T5
N5 N4
H5
T8
L4
L1
H6
H7 *
T
T8
T7
N1
N2
L2
C
T6
H4
T8
muro / wall
H
H1
H2
H3
N2 N3
N3
L3
E **
dimensioni / dimension
A*
MODELLI
models
CSA130 GM
CSA180 GM
CSA230 GM
CSA300 GM
CSA400 GM
CSA500 GM
CSA650 GM
CSA800 GM
CSA950 GM
E **
H1
H2
H3
H4
H5
H6
H7 *
L1
L2
L3
L4
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
3500
3800
4100
4600
4950
5300
6200
6650
7100
1600
1900
2200
2200
2550
2900
3050
3500
3950
950
1000 1650 1000 950 1900
905 1330 2300 2450 980 1700
1250 2150
1550
1450
1800 2600 1000 1300 2000 1250 1150 2000 1000 1230 1700 3000 3200 1270 2000
2150
2050
1550 2000 3650 4050 1560 2500
1600 2500 1700 1600 2050
2500 3500
2950
150
200
300
880
1180
1480
1330
1680
2030
1940
2390
2840
290
300
300
850
350
300
450
note: le dim ensioni A* e H7* sono com prensive del m ontaggio KIT pneum atico pulizia fascio tubiero (optional) - la dim ensione E** riferita alla distanza m inim a per le operazioni di m anutenzione (consultare m anuale )
n o te s: th e d im e n sio n s A *a n d H 7 * in c lu d e d th e in sta lla tio n o f K IT p n e u m a tic c le a n in g syste m (o p tio n a l) - th e d im e n sio n E ** it's re fe rre d to th e m in im a l d ista n c e fo r m a in te n a n c e o p e ra tio n (se e th e m a n u a l)
CS130
GM
MODEL BOILER
potenza nominale
nominal output
potenza al focolare
firebox output
tensione di rete
net tension
N1
(kW)
144,3
199,8
255,3
332,6
444
554
720
885
1053
N2
(%)
> 90
(bar)
(bar)
4,5
(C)
90
(V)
N3
(kWh)
29,4
40,6
67,7
90,4
141
80
196
110
7 h 1/4
250
140
5 h 3/4
326
184
4h
355
203
580
740
1015
1250
flangeUNI2276-67
scarico
manicotto
N4
stub-ends
N5
manicotto
sochet
113
146,9
Q.ty
180,6
T1
214,9
T2
3 h 1/2
384
221
2 h 1/2
462
276
2h
532
333
1 h 1/2
597
381
T3
T4
T5
T6
1485
1920
2330
2735
180 (20%)
T7
T8
650-950
DN 65
DN80
DN 100
DN 65
DN80
DN 100
DN 40
DN 40
DN 40
DN 25
DN 25
DN 25
DN 15
DN 15
DN 15
350
300
350
467
584
800
996
1
1
1
1
1
1
2
TIPO
UNITA'
DIMENSIONI
description
type
unit
dimension
foro
mm
50
mm
300x300
ISO7/1 - DN
20
ISO7/1 - DN
65
ISO7/1 - DN
65
hole
Boccaporto ispezione
Foro quadro
Ispection hatch
Hole square
tronchetto
nozzle
manicotto
socket
manicotto
socket
Foro quadro
Hole square
Hole+flange
Tubo+flangia
Hole+flange
1195
1580
1936
850x670
1000x710
(l./h)
590
1490
3065
1200
1400
1700
2200
mm
480x480
mm
190(CSA GM130-500)
220(CSA GM 650-950)
mm
(CSA130-230GM-340x250)
(CSA300-500GM-390x250)
(CSA650-950GM-450x300)
450
730x460
1000
130-230 300-500
DESCRIZIONE
-20 (30%)
(mm)
(Kg)
inlet water
socket
Pos.
40
450
trochetto
560
9h
flangeUNI2276-67
ritorno
discharge
q.ty
q.ty
servizi / service
3,5
52
outlet water
POS. Q.t
(dm)
mandata
950
(mm)
type
800
(Pa)
depression flue
description
650
(C)
TIPO
Pos.
500
(l.)
DESCRIZIONE
400
(C)
POS.
300
(mbar)
CSA950
GM
230
(mbar)
CSA650 CSA800
GM
GM
180
(h/min) 12 h 1/2
CSA400 CSA500
GM
GM
130
(dm)
CSA300
GM
(kW)
(Kg/h)
CSA180 CSA230
GM
GM
2400
3800
4500
2290
5200
(Kg)
1650
1800
2000
3000
3500
4100
4800
5700
6800
(Kg)
2650
3000
3400
4700
5700
6500
8600
10200
12000
(1) NOTA: nella riga del consumo a regime indicata la quantit di combustibile necessario ad alimentare il generatore. Il p.c.i. (potere calorifico inferiore) del
combustibile pari a 17.6 MJ (4.9 kWh/kg) come da tabella 7 della norma EN303-5:2012 per il combustibile di prova C
I dati qui riportati non sono impegnativi, la DALESSANDRO TERMOMECCANICA S.r.l. si riserva di modificare caratteristiche e dimensioni senza alcun preavviso
All the information here are not binding, the DALESSANDRO TERMOMECCANICA S.r.l. reserves modify features and dimensions without some notice
LDM
(1) NOTES: i n the l i ne of max fuel consumpti on i t's i ndi cated the necessary fuel amount to feedi ng the generator. The p.c .i . (i nferi or heati ng power) the c ombusti bl e
i s equal to 17.6 MJ (4.9 kWh/kg) how the tabl e 7 the rul e EN-303-5:2012 for the fuel test "C"