TECHNICAL SPECIFICATION

SERBATOIO SOLUZIONE AMMONIACALE


Equipment:
AQUA AMMONIA TANK
Date: 22/03/2019 Redecam Code: 1AI1_TK-DS-01
Job: C119001 - Lehigh Hanson (US) Equipment Code: G2-401-TK
Rev: 3 Quantity: 1
Issued by: FEF Approved by: MEA

CONDIZIONI AMBIENTALI SITE CONDITIONS Imperial units Metric units


Posizione dell'impianto Plant location 13573 Tehachapi Blvd, Kern county - Tehachapi, CA 93561
Temperatura minima Minimum temperature F: 5 °C : -15
Temperatura media Average temperature F : 71.6 °C : 22
Temperatura massima Maximum temperature F : 104 °C : 40
Altitudine Plant altitude ft s.l. : 4291' 4" m s.l. : 1308
Pressione atmosferica Atmospheric pressure inWG : 347.4 mbar : 865.4
Umidità relativa Relative Humidity % : min 71% @7°C, max 91% @30°C
Pioggia Rainfall in/year : 13.3 mm/y : 338
Vento Wind load
Codice di riferimento Reference code IBC 2012
Classe terreno Terrain class Suburban
Velocità del vento (max 10 m dal suolo) Max wind speed 10 m above ground ft/sec : 162.4 m/s : 49.5
Velocità del vento (media) Average wind speed ft/sec : 24.3 m/s : 7.4
Sismicità Earthquake hazard
Codice di riferimento Governing code UBC97 (International) IBC (USA)
Zona sismica Seismic zone UBC Zone 4 (International) IBC (USA)

SERBATOIO SOLUZIONE AMMONIACALE AQUA AMMONIA TANK


Costruttore Manufacturer by Bidder
Liquido contenuto Liquid to be stored Aqua ammonia 19% NH3 content
Tipo Type Double wall
Orientamento Orientation Vertical
Posizione Location Outdoor
Zona Atex Atex Zone no

PARAMETRI DI PROGETTO DESIGN DATA Imperial units Metric units


Capacità Capacity US gallons : 20,000 m3 : 75.7
Pressione di design serbatoio interno Inner tank design pressure psig : 30 bar : 2.1
Note: this is the min acceptable negative pressure,
Inner tank min operating negative
Minima depressione di lavoro serbatoio interno psig : -0.36 mbar : -24.5 meaning that a design negative pressure for inst. equal to -
pressure
0.2 psig is not accepted
Pressione di design serbatoio esterno Outer tank design pressure atmospheric
Dimensioni (DN x H) - Opzione 1 Dimensions (L x W x H) - Option 1 ft : 9.2x40.7 ft mm : 2800 (W) x 12400 (H) mm, outer tank
Dimensioni (DN x H) - Opzione 2 Dimensions (L x W x H) - Option 2 ft : 10.8x37 ft mm : 3300 (W) x 11277 (H) mm, outer tank
Peso Weight lb : by Bidder kg : by Bidder
Materiale Material /: carbon steel
Codice di riferimento Reference design code /: ASME VIII code stamped
Painting shall be 3 coats as follows: Primer Coat: 3-5 mils DFT Sherwin Williams Macropoxy 646
Verniciatura serbatoio esterno Outer tank external painting : epoxy primer, Intermediate Coat: 5 mils DFT Sherwin Williams Macropoxy 646 epoxy primer, Finish
Coat: 5 mils DFT Sherwin Williams Acrolon 218 urethane – White
Verniciatura serbatoio interno Inner tank internal painting : Carboline Plasite 4500 S
Verniciatura intercapedine Jacket internal painting : by Bidder

ITEMS TO BE INCLUDED
- All tank anchor chairs and lift lugs
- all tank attachments, as listed in the annex A. Tank to include all necessary ports for installation of the instrumentation listed in annex A. An additional 1-1/2” port with blind flange will be added to the tank for
plant’s possible use of a temperature sensor
- MSHA approved steel ladder (with cage and safety gate) for the access to the top of the tank from bottom of containment
- manway, handrail, toe plate and platforms on the top of the tank. The platforms shall be configured to provide easy access to all components located on the top of the tank. The design shall meet MSHA
standards. The toe plate shall be steel
- predisposition for tank grounding

NOTES
All Annexes are part of the technical specification

Tank shall be designed for all loads associated with transportation, handling, erection, and equipment mounted on the tank (including ladders, platforms, and ancillary equipment)

The tank and anchor bolt system shall be designed by the Seller for the above noted loads acting separately or in combination

All documents shall be provided in English

Seller shall provide a nameplate on all equipment with the following:


a) Manufacturer’s label with essential technical data
b) Necessary safety precautions

Stamping on the tank or on nameplate shall include, in addition to the stamping required by ASME Code: 1) the head and shell thicknesses, 2) the gross volumetric capacity in US gallons, 3) the total outside
surface area of the container in square feet

Sheet 1 of 6
TECHNICAL SPECIFICATION
SERBATOIO SOLUZIONE AMMONIACALE
Equipment:
AQUA AMMONIA TANK
Date: 22/03/2019 Redecam Code: 1AI1_TK-DS-01
Job: C119001 - Lehigh Hanson (US) Equipment Code: G2-401-TK
Rev: 3 Quantity: 1
Issued by: FEF Approved by: MEA
REFERENCE CODES AND STANDARDS

Work performed and materials furnished by Seller shall be in accordance with the codes and ordinances listed below and in accordance with all other applicable codes or standards. The latest edition or
supplement thereto in effect at the time of bidding shall be considered to be the issue in effect.
a) American Society of Mechanical Engineers (ASME)
b) American Institute of Steel Construction (AISC)
c) American Concrete Institute (ACI)
d) American Welding Society (AWS)
e) American National Standards Institute (ANSI)
f) American Society for Testing Materials (ASTM)
g) Building Officials and Code Administrators National Code (BOCA)
h) Occupational Safety and Health Administration (OSHA)
i) Occupational Safety and Health Standards for General Industry
j) C2 National Electrical Safety Code
k) Institute of Electrical and Electronics Engineers (IEEE)
l) International Electrotechnical Commission (IEC)
m) Insulated Power Cable Engineers Association (IPCEA)
n) International Building Code (IBC)
o) Mine Safety and Health Administration (MSHA)
p) National Electrical Manufacturers Association (NEMA)
q) National Fire Protection Association (NFPA)
r) NFPA 70 National Electrical Code (NEC)
s) Steel Structures Painting Council (SSPC)
t) Underwriters Laboratories (UL)
u) Division of Occupational Safety and Health (Cal/OSHA)
The Seller shall design to the intent of these codes and standards; however, the Seller has the right to take exception to a specific standard where there are conflicts with the Seller’s own processes or design
standards. If the Seller intends to take exception to a specific standard, it must state so in their proposal.

DOCUMENTATION
Preliminary with offer (not to exceed value)
Loads and foundation drawings (autocad format) allowing to the client to design and engineer the tank foundations
General arrangement drawings (autocad format)
Official 1 week from PO
Tank arrangement drawing for review/approval
Official 2 weeks from PO
ASME Section VIII design, construction, testing and stamping for vessel
Tank final G.A. drawings stamped by a licensed engineer
Material Certification Records
Weld Procedures
Seismic/Wind calculations
Hydro test report and procedures
NDE reports
1 month before delivery
O&M Manuals
Decommissioning procedure

Sheet 2 of 6
ANNEX A
LIST OF OPENINGS TO BE FORESEEN ON THE TANK

In
NOZZLE FOR communication ID in P&ID Type of connection Connection rate Size of the connection Notes
with
1 Pressure Relief Valve & Vacuum Breaker Inner wall - flanged ANSI 150# 2"
2 Level transmitter with integral display Inner wall LIT flanged ANSI 150# 4"
3 Pressure transmitter with integral display Inner wall PIT flanged ANSI 150# 4"
4 Ammonia tank high level switch Inner wall LSH flanged ANSI 150# 4"
5 Level switch, for alarm notification of accumulation of liquid in the interstice volume Outer wall LSH flanged ANSI 150# 4"
6 Drain valve, for interstice volume Outer wall - flanged ANSI 150# 2"
7 Dessiccant breather, for interstice volume Outer wall - flanged ANSI 150# 1 1/2"
8 Local temperature indicator predisposition Inner wall - flanged with cap ANSI 150# 1 1/2"
9 Lockable drain valve Inner wall - flanged ANSI 150# 2"
10 Liquid return line from the pump skid Inner wall - manual valve flanged ANSI 300# 2"
11 Liquid extraction line to the pumps Inner wall - manual valve flanged ANSI 150# 1 1/2"
12 Liquid filling up from the truck Inner wall - manual valve flanged ANSI 150# 2"
13 Vapor return to the truck Inner wall - manual valve flanged ANSI 150# 2"
14 Pressure relief vent coming from the pipeline Inner wall - flanged ANSI 300# 2"
suitable for introducing one man +
15 Manway Inner wall - bolted to be defined by Bidder Designed according to ASME VIII requirements
ladder

3
1 2
13
14 8 12
7
10

5
11

9
6

Sheet 3 of 6
OPTION 1

OUTER TANK INNER TANK


INNER SHELL THICKNESS SUMMARY OPTION 1
OPTION 2 SKETCH