Sei sulla pagina 1di 8

377387639.

xls Dilatari

Nr.
Marime Simbol U.M. Valoare
crt.
1 Diametru exterior de mm 32.0
2 Lungime conducta L m 10.0
3 Temperatura montaj tm C 10.0
4 Temperatura regim t C 80.0
5 Coef. dilatare liniara a mm/mK 0.026
6 Constanta material K --- 33.0
7 Diferenta temperatura Dt C 70.0
8 Alungire conducta Dl mm 18.2
9 Brat compensator B mm 796.388

Pag. 1/8
377387639.xls Detentor GIACOMINI

Tip robinet GIACOMINI R16 1/2"

Nr.
Marime Simbol U.M. Valoare
crt.
1 Debit apa q l/h 80.0
2 Deschidere robinet n ture 1.0
3 Coeficient debit Kv --- 0.57
4 Cadere presiune Dp mmCA 200.8
5 Cadere presiune Dp Pa 1969.8

Pag. 2/8
377387639.xls Aut Hidraulica Man. Inst. Inc.

Nr.
Marime Simbol U.M. Valoare
crt.
1 Putere termica P W 1850.0
2 Diferenta temperatura DT K 20.0
3 Banda proportionalitate BP K 2.0
Cadere de presiune
4 in racord C.I. Dp,rac bar 0.045
5 Debit apa q l/h 79.6
6 Debit apa q mc/h 0.0796
7 Coeficient debit Kv --- 0.0796
Cadere de presiune
8 in robinet Dp,rob bar 0.055
9 Autoritate hidraulica a --- 0.550

Pag. 3/8
377387639.xls Aut Hidraulica THB

Nr.
Marime Simbol U.M. Valoare
crt.
1 Putere termica P W 2000.0
2 Diferenta temperatura DT K 20.0
3 Presiune diferentiala disponibila DH kPa 32.0
4 Cadere de presiune in C.I. Dp,CI kPa 6.0
Cadere de presiune
5 in conducte, accesorii Dp,ca kPa 4.0
6 Debit apa q l/h 86.0
Cadere de presiune
7 pe vana de reglare Dp,V kPa 22.000
8 Coeficient debit necesar Kv --- 0.183
9 Coeficient debit ales Kv --- 0.25
Cadere reala de presiune
10 pe vana de reglare Dp,V' kPa 11.834
11 Autoritate hidraulica practica b' --- 0.370
12 Presiune diferentiala necompensata DH,necomp kPa 10.166
13 Presiune diferentiala necesara DH,nec kPa 21.83
14 Autoritate hidraulica teoretica b --- 0.542
15 Factor debit in exces Sq --- 1.211
16 Debit maxim prin vana q,max l/h 104.114

Pag. 4/8
377387639.xls Vana Echilibrare STAD

Vana Echilibrare STAD

Nr.
Marime Simbol U.M. Valoare
crt.
1 Debit apa q l/h 2500.0
2 Cadere presiune proiect Dp kPa 10.0
3 Coeficient debit necesar Kv --- 7.91
4 Tip vana echilibrare STAD --- DN25
5 Valoare presetare (rotatii) NR rotatii 3.50
6 Coeficient debit Kv --- 8.00
7 Presiune diferentiala reala Dp kPa 9.766
8 Tip vana echilibrare STAD --- DN32
9 Valoare presetare (rotatii) NR rotatii 2.50
10 Coeficient debit Kv --- 7.10
11 Presiune diferentiala reala Dp kPa 12.398

Pag. 5/8
377387639.xls Vana 3 Cai-Amestec

Vana Reglare cu 3 Cai: functie amestec, debit variabil in circuit primar

Nr.
Marime Simbol U.M. Valoare
crt.
1 Debit apa q l/s 2.0
2 Debit apa q l/h 7200.0
Cadere presiune proiect
3 (generator, accesorii) DpcG kPa 5.0
Presiune diferentiala necesara
4 pe vana cu 3 cai DpcV kPa 5.000
5 Coeficient debit necesar Kvs --- 32.199
6 Coeficient debit Kvs --- 25.0
7 Presiune diferentiala reala Dp kPa 8.294
8 Autoritate hidraulica practica b' --- 0.624
9 Coeficient debit Kvs --- 40.00
10 Presiune diferentiala reala Dp kPa 3.240
11 Autoritate hidraulica practica b' --- 0.393

Pag. 6/8
377387639.xls Vana 3 Cai-Ocolire

Vana Reglare cu 3 Cai: functie ocolire

Nr.
Marime Simbol U.M. Valoare
crt.
1 Debit apa q l/s 0.6
2 Debit apa q l/h 2160.0
Cadere presiune proiect
3 (consumator) DpcC kPa 20.0

Presiune diferentiala disponibila


4 DH kPa 50.0
Presiune diferentiala necesara
5 pe vana cu 3 cai DpcV kPa 20.000
6 Coeficient debit necesar Kvs --- 4.830
7 Coeficient debit Kvs --- 4.0
8 Presiune diferentiala reala Dp kPa 29.160
9 Autoritate hidraulica practica b' --- 0.593
10 Presiune diferentiala STAD-P DpSTAD-P kPa 0.840
11 Presiune diferentiala STAD-B DpSTAD-B kPa 20.000
12 Coeficient debit Kvs --- 6.00
13 Presiune diferentiala reala Dp kPa 12.960
14 Autoritate hidraulica practica b' --- 0.393
15 Presiune diferentiala STAD-P DpSTAD-P kPa 17.040
16 Presiune diferentiala STAD-B DpSTAD-B kPa 20.000

Pag. 7/8
377387639.xls Necesitate RegPresDif

Stabilire necesitate adoptare regulator presiune diferentiala

Marime Simbol U.M. Valoare


Incarcare termica de proiect
Putere termica furnizata P % 100.0%
Debit apa q % 100.0%
Sarcina pompare Hc kPa 100.0
Cadere de presiune in conducte Dpc kPa 60.0
Presiune diferentiala pe circuit DHcirc kPa 40.0
Presiune diferentiala pe vana de
reglare DpcV kPa 25.0
Autoritate hidraulica practica b' --- 0.625
Raport presiuni RDp --- 0.40
Incarcare termica redusa
Putere termica furnizata P % 50.0%
Debit apa q % 20.0%
Sarcina pompare H kPa 130.0
Factor reducere debit Fq --- 5.000
Factor reducere Dp FDp --- 25.000
Cadere de presiune in conducte Dp kPa 2.400
Presiune diferentiala pe circuit DHcirc kPa 127.600
Presiune diferentiala pe vana de
reglare inchisa DpV kPa 127.600
Autoritate hidraulica practica b' --- 0.196

Pag. 8/8