TEST CERTIFICATE KCS ©., LTD. Certificate No? KS16E-467 S 29, Sandeok-ro, Sasang-gu, Busan, Korea a ¢ Tel :82-81-841-7701, Fax :82-51-341-708 | Page ( 2 Jof( 2) 1.Client Name: HYUNDAT ENGINEERTNGEOONSTRUCTION CO.,LTD. Address : 140-2 Kye-Dong, Chongro-Gu, Seoul, Korea 2.Calibration Subject Object Compression Testing Machines(MONO JACK) Manufacturer & Model name: HO-JU HYDRAULIC MACHINERY / 250 KN Serial number : HJHD-025-200-36 3.Date of Test: 21-May-16 4.Environment : — Temp.: ( 21.9 £0.4 ) Humidity: ( 40+ 2) ® RH Location: CPermanent Lab. ClMobile Lab. Mn Site Test. (HOMJU HYDRAULIC MACHINERY) 5.Test method ‘The above Calibration subject was tested according to the KCS test method for Tension/Compression Testing Machines(KCSI-FO02) with below Standards. @ List of used standards/specificat ions 7 a The due date of next oar; Discription | Manufacturer & Nodel nane | ‘Serial No. ae fhseson [Calibration Lab LOAD CELL POINT / 300 kN Peo141 1-Mar-17 KIS 6.Test result = Refer to the attatched Test Report 7.Measurement uncertainty + Refer to the attatched Test Report [Approved by |Affirm [Measurements performed by -ation| Nene © Jun-young Kim ino IName : Tae-nyung Kim G G The above test results is performed by KCS Co., Ltd. KCS Co., Ltd.) (MOE 1f any sisiteant instability or oar atvrse factor ( cverlod, eames ats, ete.) nanifests itself before, during or after calibration, and is Likely to affect the validity of the calibration KCS-R-001(Rev.2)(210%297) am KCS TEST RESULT Certificate No: KS16E-467 Page ( 2 Jof( 2) KCS CO., LTD. iWCS Compression Test Serial Number : 16759 Resolution: 10 bar The end KCS-R-002(Rev.2)(210% 297 )am 1. * Capacity? 250 kN Tester Test Load (kN) Refference Uncertainty Reading bar] Ist 2nd 3rd Load (KN) (®) 0 0.0 0.0 0.0 0.0 0.00 120 42.2 | 42.8 42.5 42.5 13.6 240 86.1 | 86.2 86.1 86.1 67 360 131.0 | 1311 | 131.0 131.0 4.41 480 176.0 | 176.5 | 176.2 176.2 3.28 600 222.0 | 222.4 | 222.2 222.2 2.60 * indicator PAKCS ‘Naser M. AL-Baddah & Partner. Co. AS y CGM dane aS HNBTC General Trading & Contracting .W.L.L aloud) Spe CXgl—iall 9 A_olall CALIBRATION CERTIFICATE NBTCFOIC Ti/Revo Certificate No: NBTC-IC-CN-029 Issue Date: (07 March 2017 Calibration On: 06/03/2017 Job Order No: | NBTC-IC-ON-016 Due On: 05/03/2018 Page No: 10f2 j CUSTOMER DETAILS: Name Address UNIT UNDER CALIBRATION (UUC) DETAILS: Hyundai Engineering & Construction. P.O Box : 24314 SAFAT 13104, KUWAIT. Description Analog Pressure Gauge Asset No 5431832213-006 Make + ENERPAC Range 0 ~ 1000 Bar Model G 4089L_ Least Count 10 Bar | Condition of tem Satisfactory | CALIBRATION INFORMATION: Calibration Method Used DKD R6-1 Temperature 22°C Relative Humidity 50 RH STANDARD TEST EQUIPMENT USED: Certificate No Make/Model Description Traceable to Validity CS/15/LB/648-03 _GE Pressure Calibrator | Inter National Standard 10/08/2017 Remarks: 1. The calibration is performed by the comparison of the measurement results of calibration object to the values of known reference standards and standard measuring equipment that are traceable to the international System of Units(SI)through recognized National Metrology Institutes. 2. This Certificate refers only to item under calibration. Calibration Results reported are valid at the time of & under the stated conditions of measurements. Calibration Laboratory shall not be liable for any change in calibration on account of malfunctioning of the instrument due to da 4, Certificate shall not be reproduced in ful Laboratory. Calibrated By Nikhil Jayadevan (Caltration Technician) 2.0 Box 9088, madi 61002 Pot Block 5 Shuaiba Industrial Ares, Kowal = Caused after the report is issued. aithout any prior information from NBTC Calibration ‘Authorized Signatory Neenu Mampilly (Technical Manages) mal eicabration@nbtegoup.com Lab Phone No, 1867777 Extn 4516 Naser M. AL-Baddah & Partner. Co. AS y TA dee pat AS General Trading & Contracting .W.LL Spe CXgL—iall 9 @—alal erry NaTHOICITRe® CALIBRATION RESULTS Certificate No: NBTC-IC-CN-029, Issue Date: 07 March 2017 Descriptior Analog Pressure Gauge Page No: 2orz sl. nag "6 | Reference Standard Input Pressure Error £% No ___| increase (BAR) | Decrease (BAR) | Increase Decrease 1 o o o o o : 200 200.40 200.20 0.04 0.02 3 400 400.50 400.40 -0.05 0.04 a 600 600.60 600.40 0.06 0.04 5 800 800.50 800.30 0.03 - . 1000 1000.40 1000.40 -0.04 0.04 ‘+58008808* END OF CALIBRATION RESULT#*####¢¢04 9.080208, ara s004 al: ection bt gous. com Plt Block 5, Shai Indus Ares, Kowa Lab Phone Wo 1867777.Extn A516

Potrebbero piacerti anche