Sei sulla pagina 1di 4

CMS

ULTRASONIC
SYSTEM

PRODUCT PLUS
Compressional P waves time
propagation measurement through
materials

Visualization of the waveforms aimed


to a real time control

Palmtop and Bluetooth technology


allow measurement within 30m
distance from Acquisition Unit

Interchangeable transmitters allowing


use on many different types of
materials

Different acquisition settings (direct,


semi-direct, superficial)

Easy to use and high accuracy either


on laboratory tests and on site
surveys

Digital board card up to 1,25MHz


sample frequency

It fully respects Standard Guidelines


UNI EN 12504-4, ASTM D2845-08,
ASTM C597-02
SOLGEO CMS

Solgeo CMS ultrasonic system is able to perform


measures of compressional P waves time
propagation through different materials, with high
accuracy by allowing to visualize on a palmtop or
tablet PC the waveform of signal acquired.

It is made up of an acquisition unit and different


piezoelectric sensors among which high power
piezoeletrical transmitter (> 1.6 kV) and a
triggered hammer. It means extremely wide range
of use, even on bad quality materials.

High sensitivity of piezoelectric receivers,


frequency 55 kHz (optionally 80-20 kHz), allows
very high accuracy measurements both on
laboratory and on site surveys.

The palmtop, working with a Bluetooth technology,


can perform measurements within 30 m far from
the acquisition unit.

CMS is provided with DATASONIC software


package for downloading, processing and data
editing

Lapparecchiatura ultrasonica Solgeo CMS misura il tempo


di propagazione delle onde compressionali (onde P)
nei materiali con elevata precisione ed inoltre permette
la visualizzazione della forma donda effettiva del
segnale acquisito su di un computer palmare o tablet PC
controllandone la qualit in tempo reale.

costituita da una unit di acquisizione dati e da una


serie di sensori piezoelettrici tra cui un trasmettitore
piezoelettrico ad alta potenza ( >1.6 kV) ed un martello
strumentato che permettono un impiego anche in materiali
con scarse caratteristiche di propagazione e velocit.

Lelevata sensibilit dei ricevitori piezoelettrici, con


frequenza 55 kHz (opzionale 20 kHz), consentono di
effettuare misure estremamente precise sia su provini di
laboratorio sia in indagini in sito.

Il palmare, grazie alla tecnologia Bluetooth permette di


eseguire le misure in un raggio di 30 mt dallunit di
acquisizione.

Lapparecchiatura corredata dal software DATASONIC


per lo scarico, lelaborazione e la rappresentazione dei
dati acquisiti.
The transmitter sensor is equipped with a push-
button allowing the remote control of Data
Acquisition Unit (starting the measurement,
storing measured data, resetting the unit). This
procedure allows to operate far from the Central
Unit. Furthermore this set-up allows to manage the
system by only one person.

The HAMMER-Transducer equipping the CMS


System , characterized by low frequency and high
energy, is recommended when the energy is not
sufficient (e.g. materials with low propagation
characteristics, monumental masonry) and/or
materials of very large size.

La sonda trasmittente grazie ad un pulsante permette di


comandare a distanza lunit di acquisizione per eseguire
le diverse operazioni di misura (start, memorizzazione dei
dati, passaggio alla misura seguente). cos possibile
operare anche a una certa distanza dallacquisitore con
limpiego di un sol operatore.

Lapparecchiatura pu essere integrata con il sistema di


trasmissione sonico con martello strumentato per effettuare
misure laddove le caratteristiche dei materiali da indagare
(ad es. murature a sacco) o le distanze da percorrere
non siano raggiungibili con il sistema ultrasonico ad alta
frequenza.

Impulse frequency TSG55 = 55KHz TSG-Hi20 = 20 KHz CHARACTERISTICS


Transmission Pulse,
Voltage
1,6kV 1.6kV OF THE
Energy approx. 0,05 Joule approx.0,2 Joule PIEZOELECRICT
Weight 770 gr. 1450 gr
TRANSMITTER
Dimension :50mm x l:75 mm 1450 gr
TECHNICAL FEATURES

Converter type A/D, 12 bit converter


Display range +/- 2.5 Volt
Amplification Software driven; selectable gains: x 10, x 100, x 1000, x 5000
Acquisition frequency From 50Khz to 1.25Mhz
Standard 4096 samples (optional up to 8192 samples
Acquisition Buffer Duration of Acquisition from 0.32 ms to 400ms (option 800ms)
Standard multi-purpose connector with direct insertion into the PDA:
I/O between Central
I/O Central Unit PDA: Bluetooth, reach about 30 m.
Unit & internal PDA Internal PDA battery reloading
Surface mounted connector Type DB15:
I/O between Central I/O Central Unit - PC (use without PDA): RS232 serial type, baud rate
Unit & external PC selectable from 1200 to 115.000 bps.
USB I/O to transfer data from the internal PDA to an external PC
VDE connector 110 a 240Vac 50-60Hz:
Internal battery recharging unit: 500mA.
Internal PDA Power Supply: 5Vdc, 2A.
Power Supply Internal battery: 12V, 3.2Ah.
Stand-by: 50 hours, in operation: 10 hours.
Total recharging time: 8 hours
Receivers: Piezoelectric type, 55 kHz resonance frequency, optional
20-80 kHz,
internally pre-amplified Receiver - 20 dB.

- Transmitter: Piezoelectric type: Voltage for transmission pulse: 1,6


KV, with
Transducers trigger push-button for remote control functions, data acquisition
functions, signal
freeze and storage of data for data profile management.

- Ready for use with piezoelectric Hammer Transducer for low fre-
quency signal
measurements

SOLGEO S.r.l.: Via Pastrengo 9, 24068 Seriate (BG) - Tel. +39 035 4520075
Web site: www.solgeo.eu e-mail:info@solgeo.it

Potrebbero piacerti anche