Sei sulla pagina 1di 2

0 1 2 3 4 5 6 7 8 9

149
V1 V2
150 Visualizzatore Visualizzatore

SE1
151
1 2 3 10 11 1 2 3 10 11

501
502
503

505
506
507
13

13
5

5
FU1 FU3
3x40A 4A
FR1
.3
149

150

151

152

153

154

155

151

3
SB1 BQ1 BQ2
TV1
80VA
220-380V

4
24V

01
5
SB2
KL
.5
FU4
1x10A

6
1
SA1 KL KL
.5 .5

Q1 FR1
15ö32A
.5
U

13
7
M1
15 KW
L1

L2

L3

KL H1
TV2
20000VA
PRI:230V
SEC:400V

START
L1 L2 L3 L1 L2 L3
MOTOR M1

.6
.5
.2
400V - 60Hz 230V - 60Hz
.2
.3

2
Data =
Faccin srl 3HCD POWER 3HCD 15KW
Elab. UAA +

Appr. 16.Dic.2011 3HCD 15KW 230-400V Fg. 1


Modifica Data Nome Norma Orig. Sost. il Sost. da 2 Fg.
0 1 2 3 4 5 6 7 8 9

NAME Q.ty DESCRIPTION CODE BUILDER FACCIN CODE

BQ1 1 Linear transducer stroke=150 PZ34.A.150 GEFRAN SPA 920.033.115

BQ2 1 Linear transducer stroke=150 PZ34.A.150 GEFRAN SPA 920.033.115

FR1 1 Thermal relay 25ö32A RT1 25ö32A GE Power Controls

FU1 3 Fuses 40A 40A CH14 - 1431040 WEBER 920.023.000.040

FU3 1 Fuses 4A 4A CH10 - 1421004 WEBER 920.023.000.004

FU4 1 Fuses 10A 10A CH10 - 1421010 WEBER 920.023.000.010

H1 1 Light (green) P9MLD53610 GE Power Controls

KL 1 Contactor CL04 GE Power Controls

Q1 1 Three poles switch 40A DILOS 00 40A - D/061304-201 GE Power Controls 920.031.000.040

SA1 1 Push-button (black) - 1NO P9MPN53007 GE Power Controls

SB1 1 Mushroom head push-button - 1NC P9MER4RN GE Power Controls

SB2 1 Mushroom head push-button - 1NC P9MER4RN GE Power Controls

SE1 1 Emergency rope limit-switch 90ø FD 1883 PIZZATO 920.030.008

TV1 1 80VA PRI:220-380V SEC:24V 50/60Hz 80VA 6462 BRAGA TRASFORMATORI

TV2 1 20000VA PRI:230V SEC:400V 60Hz 20000VA 14156 BRAGA TRASFORMATORI

V1 1 Digital display 4T-96-4-01-0 4T-96-4-01-0 GEFRAN SPA 920.035.008

V2 1 Digital display 4T-96-4-01-0 4T-96-4-01-0 GEFRAN SPA 920.035.008

1
Data 16.Dic.2011 =
Faccin srl 3HCD COMPONENTS LIST 3HCD 15KW
Elab. UAA +

Appr. 16.Dic.2011 3HCD 15KW 230-400V Fg. 2


Modifica Data Nome Norma Orig. Sost. il Sost. da 2 Fg.