SPECIFICATION
This set of Specifications shall administer the methods of construction
as well as the kinds of materials to be used for the proposed building shown
in the plans and detailed drawings.
The plans, detailed drawings and these Specifications shall be
complementing each other so that what is shown in one, although not shown
in the other, shall be considered as appearing on both.
GENERAL CONDITIONS
All parts of the construction shall be finished with first class
workmanship to the fullest extent of the meaning of plans and specification.
These specifications are intended to cover the construction of the proposed
Two-Storey Residential Building as shown on the plans and described in
these specifications.
The construction shall conform to all the requirements of the National
Building Code, as well as the local rules and regulations of the
Municipality/City of Cagayan de Oro, Philippines.
2.0 REINFORCEMENT
# 16 G.I Wire
- To be used for all steel bar intersections
The concrete hollow block walls shall be laid, and the cells filled
with the cement mortar consisting 1 part of Portland cement and 3
parts sand by volume. They shall be reinforced with round deformed
bars with 10mm diameter, spaced not more than 0.80 on centers, both
ways.
E. DIVISION 5 - METALS
Install a 10mm double sided insulator in the top cord of the roof
frame and in the ceiling area.
Doors and door frames shall conform to the sizes, design and
kind of materials shown in the schedule of doors and windows or as
per the bill of materials.
2.0 WINDOWS
Steel casement windows for all window sets on sides and rear
with 3/16 thk. Glass to be provided with insect screen incorporated on
the window frame and fire escape. Size of bars to be used shall be
sq. bar. Verify also the design and sizes of windows reflected on
working drawings.
1.0
I. DIVISION 9 - FINISHES
DIVISION 10 - SPECIALTIES
1.0 In the toilet and bath accessories use the FLOVA bathroom or its
equivalent.
K. DIVISION 15 - MECHANICAL
L. DIVISION 12 - ELECTRICAL
The spare circuit shall be provided with an empty PVC pipe, size
19mm diameter which should extend at least 300mm aboce the ceiling
line. The grounding wires shall be identified and all wires shall be
color-coded for easy identification.
The panelboard shall be provided with a circuit directory.