/ Rev. 0 1 8 NORMALIZZAZIONE INTERNA 11602.EQP.ELE.STD CODICE - Code Sheet - of Compiled Date 1 INTERNAL NORMALIZATION F.V. Maggio '96 CASSONETTO M.T. IN OLIO M.V. oil filled disconnecting chamber TRASFORMATORI DI POTENZA IN OLIO Oil immersed power transformer Documento di proprieta' aziendale. La Societa' tutelera' i propri diritti a termini di legge. This document is Companyproperty. The Companylawfullyreserves all rights. C TR 3 8 3 6 1 4 2 4 5 7 12 10 11 9 drain plug cable lug legend separating plate 6 - CAPOCORDA 3 - FLANGIA 1 - CAMERA TERMINALI 5 - PIASTRA DI SEPARAZIONE cover for connecting and inspection 4 - COPERCHIO PER ISPEZIONE E COLLEGAMENTO 2 - ISOLATORE PASSANTE connector and disconnecting chamber flange bushing LEGENDA / 9 - ESSICATORE SILICAGEL 8 - CAVO ISOLATO IN CARTA 12 - VALVOLA DI SCARICO 11 - INDICATORE DI LIVELLO 10 - TAPPO DI RIEMPIMENTO paper-insulated cable silica gel dryer filling plug oil level indicator 7 - TERMINALE cable termination L Agip Foglio / di Compilato Data / Rev. 0 2 8 NORMALIZZAZIONE INTERNA 11602.EQP.ELE.STD CODICE - Code Sheet - of Compiled Date 1 INTERNAL NORMALIZATION F.V. Maggio '96 CASSONETTO M.T. IN ARIA M.V. air filled disconnecting chamber TRASFORMATORI DI POTENZA IN OLIO With connection chamber Documento di proprieta' aziendale. La Societa' tutelera' i propri diritti a termini di legge. This document is Companyproperty. The Companylawfullyreserves all rights. e e to earthing ALLA RETE DI TERRA 10 7 3 9 2 1 10 8 6 5 10 11 7 2 4 1 2 7 9 2 10 3 5 8 6 TR L C cable gland legend bushing flange connector and disconnecting chamber 2 - ISOLATORE PASSANTE 4 - COPERCHIO PER ISPEZIONE E COLLEGAMENTO cover for connecting and inspection 5 - PIASTRA FISSACAVI RIMOVIBILE 1 - CAMERA TERMINALI 3 - FLANGIA 6 - FISSAGGIO TERMINALE removable cable gland plate LEGENDA / extruded-insulated cable 10 - VALVOLA DI DRENAGGIO 11 - BULLONE PASSANTE DI TERRA DIAMETRO > 12 mm 8 - CAVO CON ISOLANTE ESTRUSO 9 - CAPOCORDA earthing bolt, diameter > 12 mm drain valve cable lug cable termination 7 - TERMINALE Agip Foglio / di Compilato Data / Rev. 0 3 8 NORMALIZZAZIONE INTERNA 11602.EQP.ELE.STD CODICE - Code Sheet - of Compiled Date 1 INTERNAL NORMALIZATION F.V. Maggio '96 TRASFORMATORI DI POTENZA IN OLIO Oil immersed power transformer CASSONETTO B.T. IN ARIA E CAVI UNIPOLARI L.V. air filled disconnecting chamber for single core cables Documento di proprieta' aziendale. La Societa' tutelera' i propri diritti a termini di legge. This document is Companyproperty. The Companylawfullyreserves all rights. 3 2 9 1 7 4 5 8 6 9 3 2 5 3 10 e n a c b 10 9 TR L C 4 - COPERCHIO PER ISPEZIONE E COLLEGAMENTO cable gland plate, non-magnetic or with non-magnetic 5 - PIASTRA PORTA PRESSACAVI, NON MAGNETICA cover for connecting and inspection 10 - MESSA A TERRA NEUTRO; QUANDO NON E' PREVISTA LA MESSA A TERRA DEL NEUTRO, legend 3 - FLANGIA 1 - CASSONETTO DI PROTEZIONE 2 - ISOLATORE PASSANTE bushing protection chamber flange LEGENDA / connection terminals 7 - TERMINALI cable gland or timber clamps with rubber seals single-core cable 6 - PRESSACAVI O REGOLI IN LEGNO CON TENUTA IN GOMMA 8 - CAVO UNIPOLARE O CON INSERTI NON MAGNETICI TRA I FORI inserts between holes 9 - VALVOLA DI DRENAGGIO drain valve CHIUDERE IL FORO DELLA PIASTRA direct earthing of neutral; when there is no earthing of neutral close hole on plate Agip Foglio / di Compilato Data / Rev. 0 4 8 NORMALIZZAZIONE INTERNA 11602.EQP.ELE.STD CODICE - Code Sheet - of Compiled Date 1 INTERNAL NORMALIZATION F.V. Maggio '96 TRASFORMATORI DI POTENZA IN OLIO Oil immersed power transformer CASSONETTO B.T. IN ARIA E CAVI UNIPOLARI L.V. air filled disconnecting chamber for single core cables Documento di proprieta' aziendale. La Societa' tutelera' i propri diritti a termini di legge. This document is Companyproperty. The Companylawfullyreserves all rights. 1 7 4 12 e n a c b 5 6 10 11 9 8 3 2 * 13 12 3 2 12 2 7 3 12 9 11 8 6 1 6 13 12 5 6 legend LEGENDA / L C TR protection chamber 2 - ISOLATORE PASSANTE 1 - CASSONETTO DI PROTEZIONE cover for connecting and inspection 4 - COPERCHIO PER ISPEZIONE E COLLEGAMENTO flange bushing 3 - FLANGIA 5 - SBARRE DI CONNESSIONE removable flexible bus-bars 7 - RACCORDI FLESSIBILI connection bus bars insulation supports (clamps) 6 - SUPPORTI ISOLANTI (DIAFRAMMI) O CON INSERTI NON MAGNETICI TRA I FORI 8 - PIASTRA PORTA PRESSACAVI, NON MAGNETICA cable gland plate, non-magnetic or with non-magnetic inserts between holes cable glands 9 - PRESSA CAVI 10 - TERMINALI connection terminal single-core cable 11 - CAVO UNIPOLARE drain valve 12 - VALVOLA DI DRENAGGIO CHIUDERE IL FORO DELLA PIASTRA of neutral close hole on plate direct earthing of neutral; when there is no earthing 10 - MESSA A TERRA NEUTRO; QUANDO NON E' PREVISTA LA MESSA A TERRA DEL NEUTRO, Agip Foglio / di Compilato Data / Rev. 0 5 8 NORMALIZZAZIONE INTERNA 11602.EQP.ELE.STD CODICE - Code Sheet - of Compiled Date 1 INTERNAL NORMALIZATION F.V. Maggio '96 TRASFORMATORI DI POTENZA IN OLIO Oil immersed power transformer COLLEGAMENTO CON CONDOTTO SBARRE B.T. Connected with L.V. bus duct Documento di proprieta' aziendale. La Societa' tutelera' i propri diritti a termini di legge. This document is Companyproperty. The Companylawfullyreserves all rights. 1 7 4 10 5 6 10 8 3 2 3 2 10 2 7 3 10 1 6 9 9 3 10 11 3 10 8 5 C L TR direct earthing of neutral; when there is no earthing of neutral close hole on plate 8 - PIASTRE DI CONNESSIONE 7 - RACCORDI FLESSIBILI 10 - VALVOLA DI DRENAGGIO 9 - FLANGIA DI CHIUSURA 11 - MESSA A TERRA NEUTRO; QUANDO NON E' protection chamber 2 - ISOLATORE PASSANTE 1 - CASSONETTO DI PROTEZIONE cover for connecting and inspection 4 - COPERCHIO PER ISPEZIONE E COLLEGAMENTO 3 - FLANGIA flange bushing LEGENDA / legend removable flexible connections CHIUDERE IL FORO DELLA PIASTRA PREVISTA LA MESSA A TERRA DEL NEUTRO, closing flange bus-bars connection plate drain valve 6 - SUPPORTI ISOLANTI (DIAFRAMMI) insulator support (clamp) connection bus-bars 5 - SBARRE DI CONNESSIONE C L TR Agip Foglio / di Compilato Data / Rev. 0 6 8 NORMALIZZAZIONE INTERNA 11602.EQP.ELE.STD CODICE - Code Sheet - of Compiled Date 1 INTERNAL NORMALIZATION F.V. Maggio '96 TRASFORMATORI DI POTENZA IN OLIO Oil immersed power transformer TIPICO COLLEGAMENTO A.T. CON CONDUTTORI AEREI Typical H.V. connection with overhead conductors Documento di proprieta' aziendale. La Societa' tutelera' i propri diritti a termini di legge. This document is Companyproperty. The Companylawfullyreserves all rights. 4 3 2 1 5 6 CASSONE TASFORMATORE trasformer tank LEGENDA / legend 5 - CONNESSIONE IN CORDA connection to overhead conductor pipe connection 6 - CONNESSIONE IN TUBO Buchholz relay 1 - TERMINALE PER ESTERNO ISOLATO IN OLIO 2 - CONSERVATORE OLIO insulated oil terminal oil conservator inspection porthole 3 - OBLO' DI ISPEZIONE 4 - RELE' BUCHHOLZ Agip Foglio / di Compilato Data / Rev. 0 7 8 NORMALIZZAZIONE INTERNA 11602.EQP.ELE.STD CODICE - Code Sheet - of Compiled Date 1 INTERNAL NORMALIZATION F.V. Maggio '96 TRASFORMATORI DI POTENZA IN OLIO Oil immersed power transformer TIPICO COLLEGAMENTO A.T. CON CAVO ISOLATO IN OLIO FLUIDO Typical H.V. connection to oil filled cable Documento di proprieta' aziendale. La Societa' tutelera' i propri diritti a termini di legge. This document is Companyproperty. The Companylawfullyreserves all rights. 7 3 2 1 10 9 4 5 6 5 2 2 8 CASSONE TRASFORMATORE transformer tank 1 - TERMINALE PER CAVO ISOLATO IN OLIO FLUIDO coupling flange 5 - FLANGIA DI ACCOPPIAMENTO 2 - OBLO' DI ISPEZIONE E COLLEGAMENTO 4 - GIUNTO DI DILATAZIONE 3 - COLLEGAMENTO ELETTRICO electrical connection porthole for inspection and connection expansion joint 6 - RELE' BUCHHOLZ Buchholz relay terminal oil filled cable LEGENDA / legend oil conservator 7 - CONSERVATORE OLIO filling plug 8 - TAPPO DI RIEMPIMENTO 9 - VALVOLA DI SCARICO drain plug Agip Foglio / di Compilato Data / Rev. 0 8 8 NORMALIZZAZIONE INTERNA 11602.EQP.ELE.STD CODICE - Code Sheet - of Compiled Date 1 INTERNAL NORMALIZATION F.V. Maggio '96 TRASFORMATORI DI POTENZA IN OLIO Oil immersed power transformer TIPICO COLLEGAMENTO A.T. CON CONDOTTO SBARRE ISOLATO IN SF6 Typical H.V. connection with SF6 insulated bus-duct Documento di proprieta' aziendale. La Societa' tutelera' i propri diritti a termini di legge. This document is Companyproperty. The Companylawfullyreserves all rights. 1 3 2 5 4 6 7 CASSONE TRASFORMATORE transformer tank 7 - FLANGIA DI ACCOPPIAMENTO coupling flange expansion joint 6 - GIUNTO DI DILATAZIONE inspection porthole electrical connection 3 - COLLEGAMENTO ELETTRICO 4 - OBLO' DI ISPEZIONE 5 - TUBO DI COLLEGAMENTO AL CONSERVATORE DELL'OLIO pipe connection to oil conserver 2 - TERMINALE ISOLATO IN OLIO 1 - CONDOTTO ISOLATO IN SF6 LEGENDA / SF6 insulated bus-duct oil insulated cable termination legend