Gas Chromatography and Mass Spectrometry: A Practical Guide
Gas Chromatography and Mass Spectrometry: A Practical Guide
Gas Chromatography and Mass Spectrometry: A Practical Guide
Ebook997 pages8 hours

Gas Chromatography and Mass Spectrometry: A Practical Guide

Rating: 5 out of 5 stars

5/5

()

Read preview

About this ebook

The second edition of Gas Chromatography and Mass Spectrometry: A Practical Guide follows the highly successful first edition by F.G. Kitson, B.S. Larsen, and C.N. McEwen (1996), which was designed as an indispensible resource for GC/MS practitioners regardless of whether they are a novice or well experienced. The Fundamentals section has been extensively reworked from the original edition to give more depth of an understanding of the techniques and science involved with GC/MS. Even with this expansion, the original brevity and simple didactic style has been retained. Information on chromatographic peak deconvolution has been added along with a more in-depth understanding of the use of mass spectral databases in the identification of unknowns. Since the last edition, a number of advances in GC inlet systems and sample introduction techniques have occurred, and they are included in the new edition. Other updates include a discussion on fast GC and options for combining GC detectors with mass spectrometry. The section regarding GC Conditions, Derivatization, and Mass Spectral Interpretation of Specific Compound Types has the same number of compound types as the original edition, but the information in each section has been expanded to not only explain some of the spectra but to also explain why certain fragmentations take place. The number of Appendices has been increased from 12 to 17. The Appendix on Atomic Masses and Isotope Abundances has been expanded to provide tools to aid in determination of elemental composition from isotope peak intensity ratios. An appendix with examples on "Steps to follow in the determination of elemental compositions based on isotope peak intensities" has been added. Appendices on whether to use GC/MS or LC/MS, third-party software for use in data analysis, list of information required in reporting GC/MS data, X+1 and X+2 peak relative intensities based on the number of atoms of carbon in an ion, and list of available EI mass spectral databases have been added. Others such as the ones on derivatization, isotope peak patterns for ions with Cl and/or Br, terms used in GC and in mass spectrometry, and tips on setting up, maintaining and troubleshooting a GC/MS system have all been expanded and updated.
  • Covers the practical instruction necessary for successful operation of GC/MS equipment
  • Reviews the latest advances in instrumentation, ionization methods, and quantitation
  • Includes troubleshooting techniques and a variety of additional information useful for the GC/MS practitioner
  • A true benchtop reference
  • A guide to a basic understanding of the components of a Gas Chromatograph-Mass Spectrometer (GC-MS)
  • Quick References to data interpretation
  • Ready source for information on new analyses
LanguageEnglish
Release dateMay 17, 2011
ISBN9780080920153
Gas Chromatography and Mass Spectrometry: A Practical Guide

Related to Gas Chromatography and Mass Spectrometry

Related ebooks

Science & Mathematics For You

View More

Related articles

Reviews for Gas Chromatography and Mass Spectrometry

Rating: 5 out of 5 stars
5/5

3 ratings0 reviews

What did you think?

Tap to rate

Review must be at least 10 words

    Book preview

    Gas Chromatography and Mass Spectrometry - O. David Sparkman

    Table of Contents

    Cover Image

    Copyright

    Preface

    Acknowledgments

    Chapter 1. Introduction and History

    1.1. Instrumental Variables

    1.2. Operational Variables

    Chapter 2. Gas Chromatography

    2.1. Overview of a Gas Chromatograph

    2.2. Sample Introduction

    2.3. Separation of Components in the GC System

    2.4. Overview of GC Detectors

    2.5. Adding Versatility to the GC/MS System with Valves, Splitters, and Thermal Modulators

    Chapter 3. The GC/MS Interface

    3.1. Open-Split Interface

    3.2. Jet Separator

    Chapter 4. Mass Spectrometry Instrumentation

    4.1. Overview of Mass Spectrometers

    4.2. Resolution, Resolving Power, and Mass Accuracy

    4.3. Vacuum System

    4.4. Ionization Types

    4.5. m/z Analyzer Types

    4.6. Ion Detection

    4.7. m/z Scale Calibration

    4.8. Tuning the Mass Spectrometer

    4.9. Data Acquisition

    4.10. Tandem Mass Spectrometry (MS/MS)

    4.11. Conclusion

    Chapter 5. Mass Spectral Data Interpretation

    5.1. Using the Database Search

    5.2. Identification of a Molecular Ion Peak in an EI Mass Spectrum

    5.3. What to Do If There Is No Molecular Ion Peak

    5.4. Selecting the Spectrum to Be Interpreted

    5.5. Reading an EI Mass Spectrum

    5.6. Final Remarks

    Chapter 6. Quantitation with GC/MS

    6.1. Introduction

    6.2. Selection of the Quantitation Ion

    6.3. Quantitation Methods

    6.4. Making Standard Solutions

    6.5. External Standard Method

    6.6. Internal Standard Method

    6.7. Standard Additions

    6.8. Concluding Remarks

    Chapter 7. Acids

    7.1. GC Separations of Underivatized Carboxylic Acids

    7.2. General Derivatization Procedure for C8–C24 Carboxylic Acids

    7.3. GC Separation of Derivatized Carboxylic Acids

    7.4. Mass Spectral Interpretation

    Chapter 8. Alcohols

    8.1. GC Conditions for Underivatized Alcohols

    8.2. TMS Derivative of >C10 Alcohols

    8.3. Mass Spectral Interpretation

    8.4. Aminoalcohols

    Chapter 9. Aldehydes

    9.1. GC Separation of Underivatized Aldehydes

    9.2. Derivatization of Formaldehyde

    9.3. Mass Spectra of Aldehydes

    Chapter 10. Amides

    10.1. GC Separation of Underivatized Amides

    10.2. Derivatization of Amides

    10.3. GC Separation of Derivatized Amides (TMS or Methyl-8®)

    10.4. Mass Spectra of Amides

    10.5. Mass Spectra of Derivatized Amide

    Chapter 11. Amines

    11.1. GC Separations of Underivatized Amines

    11.2. Derivatization of Amines and Diamines

    11.3. GC Separation of Derivatized Amines

    11.4. Mass Spectral Interpretation of Amines

    11.5. Amino Alcohols (Aliphatic)

    11.6. Aminophenols

    11.7. Solvent Consideration

    Chapter 12. Amino Acids

    12.1. GC Separation

    12.2. Derivatization of Amino Acids and PTH–Amino Acids

    12.3. Mass Spectral Interpretation

    Chapter 13. Common Contaminants

    13.1. Contaminants Occasionally Observed after Derivatization with TMS Reagents

    13.2. Contaminants Occasionally Observed in Underivatized Samples

    13.3. Column Bleed

    Chapter 14. Drugs and Their Metabolites

    14.1. GC Separations

    14.2. Sample Preparation

    14.3. Derivatization of Drugs and Metabolites

    14.4. Mass Spectral Interpretation

    Chapter 15. Esters

    15.1. GC Separation of Esters of Carboxylic Acids

    15.2. Mass Spectra of Esters

    Chapter 16. Ethers

    16.1. GC Separation of Ethers

    16.2. Mass Spectra of Ethers

    Chapter 17. Fluorinated Compounds

    17.1. GC Separations

    17.2. Mass Spectra of Fluorinated Compounds

    Chapter 18. Gases

    18.1. GC Separations

    18.2. General Information

    Chapter 19. Glycols

    19.1. GC Separations

    19.2. Derivatization of Dry Glycols and Glycol Ethers

    19.3. Mass Spectral Interpretation

    Chapter 20. Halogenated Compounds (Other Than Fluorinated Compounds)

    20.1. GC Separations

    20.2. Mass Spectra of Halogenated Compounds (Other Than Fluorinated Compounds)

    Chapter 21. Hydrocarbons

    21.1. GC Separation of Hydrocarbons

    21.2. Mass Spectra of Hydrocarbon Compounds

    Chapter 22. Isocyanates

    22.1. GC Separations

    22.2. Mass Spectral Interpretation

    Chapter 23. Ketones

    23.1. GC Separation of Ketones

    23.2. Derivatives of Ketones

    23.3. Mass Spectra of Ketones

    Chapter 24. Nitriles

    24.1. GC Separation of Nitriles

    24.2. Mass Spectra

    Chapter 25. Nitroaromatics

    25.1. GC Separation of Nitroaromatics

    25.2. Mass Spectra of Nitroaromatics

    Chapter 26. Nitrogen-Containing Heterocyclic Compounds

    26.1. GC Separations of Nitrogen-Containing Heterocyclic Compounds

    26.2. Mass Spectra of Nitrogen-Containing Heterocyclics

    Chapter 27. Nucleosides (TMS Derivatives)

    27.1. Derivatization

    27.2. GC Separation of Derivatized Nucleosides

    27.3. Mass Spectra of TMS–Nucleosides [2]

    Chapter 28. Pesticides

    28.1. Chlorinated Pesticides

    28.2. Organophosphorus Pesticides

    28.3. Mass Spectra of Pesticides

    Chapter 29. Phenols

    29.1. GC Separations of Underivatized Phenols and Dihydroxybenzenes

    29.2. Derivatization of Phenols and Dihydroxybenzenes

    29.3. GC Separations of Derivatized Phenols and Dihydroxybenzenes

    29.4. Mass Spectra of Phenols

    29.5. Aminophenols

    29.6. Antioxidants

    Chapter 30. Phosphorus Compounds

    30.1. GC Separations

    30.2. Mass Spectra of Phosphorus Compounds

    Chapter 31. Plasticizers and Other Polymer Additives (Including Phthalates)

    31.1. GC Separations

    31.2. Mass Spectra

    Chapter 32. Prostaglandins (MO–TMS Derivatives)

    32.1. Derivatization (MO–TMS)

    32.2. GC Separation of Derivatized Prostaglandins

    32.3. Mass Spectra of MO–TMS Derivatives of Prostaglandins

    Chapter 33. Solvents and Their Impurities

    33.1. GC Separations of Industrial Solvent Mixtures

    33.2. GC Separations of Impurities in Industrial Solvents

    33.3. Mass Spectra of Solvents and Their Impurities

    Chapter 34. Steroids

    34.1. GC Separation of Underivatized Steroids

    34.2. Derivatization of Steroids

    34.3. GC Separation of Derivatized Steroids

    34.4. Mass Spectra of Underivatized Steroids

    34.5. Mass Spectra of TMS Derivatives of Steroids

    34.6. Mass Spectra of MO–TMS Derivatives

    Chapter 35. Sugars (Monosaccharides)

    35.1. GC Separation of Derivatized Sugars

    35.2. Mass Spectral Interpretation

    Chapter 36. Sulfur Compounds

    36.1. GC Separations

    36.2. Mass Spectra of Sulfur Compounds

    Appendix A. Definitions of Terms Related to Gas Chromatography

    Appendix B. Definitions of Terms Related to Mass Spectrometry

    Appendix C. Atomic Masses and Isotope Abundances and Other Information for the Determination of an Elemental Composition from Isotope Peak Intensity Ratios

    Appendix D. X+1 and X+2 Values for Ions Containing Atoms of C and H Based on Isotope Contributions

    Appendix E. Isotope Peak Patterns for Ions Containing Atoms of Cl and/or Br

    Appendix F. Steps to Follow in the Determination of an Elemental Composition Based on Isotope Peak Intensity Ratios

    Appendix G. Derivatization in GC/MS

    Appendix H. Points of Comparison of LC/MS vs GC/MS

    Appendix I. List of Available EI Mass Spectral Databases

    Appendix J. Information Required for Reporting a GC/MS Analysis

    Appendix K. Third-Party Software for Use with GC/MS

    Appendix L. GC Installation and Maintenance

    Appendix M. Troubleshooting Common GC Problems

    Appendix N. Maintenance, Operating Tips, and Troubleshooting for Mass Spectrometers

    Appendix O. Mixtures for Determining Mass Spectral Resolution

    Appendix P. Cross-Index Chart for GC Stationary Phases

    Appendix Q. Ions for Determining Unknown Structures

    Index

    Copyright © 2010 Elsevier Inc.. All rights reserved.

    Copyright

    Academic Press is an imprint of Elsevier

    30 Corporate Drive, Suite 400, Burlington, MA 01803, USA

    525 B Street, Suite 1900, San Diego, California 92101-4495, USA

    The Boulevard, Langford Lane, Kidlington, Oxford, OX51GB, UK

    Second edition 2011

    Copyright © 2011 Elsevier Inc. All rights reserved.

    No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher.

    Permissions may be sought directly from Elsevier’s Science & Technology Rights Department in Oxford, UK: phone: (+44) 1865 843830, fax (+44) 1865 853333, E-mail: permissions@elsevier.com. Alternatively you can submit your request online by visiting the Elsevier web site at http://elsevier.com/locate/permissions and selecting Obtaining permission to use Elsevier material

    Library of Congress Cataloging-in-Publication Data

    Sparkman, O. David (Orrin David), 1942–

    Gas chromatography and mass spectrometry : a practical guide / O David Sparkman,

    Zelda E. Penton, Fulton G. Kitson. – 2nd ed.

    p. cm.

    Includes index.

    ISBN 978-0-12-373628-4

    1. Gas chromatography. 2. Mass spectrometry. I. Penton, Zelda E.

    II. Kitson, Fulton G. III. Title.

    QD79.C45S66 2011

    543′.85–dc22

    2010027725

    British Library Cataloguing in Publication Data

    A catalogue record for this book is available from the British Library

    ISBN-13: 978-0-12-373628-4

    For information on all Academic Press publications visit our web site at elsevierdirect.com

    Printed and bound in USA

    11 12 9 8 7 6 5 4 3 2 1

    Preface

    The purpose of this book is to provide the practitioner of gas chromatography/mass spectrometry (GC/MS) with tools that will facilitate performing analyses and extracting information from the data of those analyses. To those ends, information regarding the tools available and a treatise on the evolution of the technique are also included. This book is not intended to be a detailed text on the theory of the technique of GC/MS; it includes information only on separation of components by gas chromatography (GC) followed by identification using mass spectrometry. No information is included on liquid chromatography/mass spectrometry (LC/MS).

    In Section I. The Fundamentals on GC/MS, the available instrumentation and techniques (Chapter 1, Chapter 2, Chapter 3, Chapter 4, Chapter 5 and Chapter 6) have been greatly expanded over the first edition. More attention is given to available databases of electron ionization (EI) spectra, their use, and the use of programs for deconvolution of coeluting chromatographic components using the mass spectral data as well as software that can be used to develop elemental compositions from mass spectral peaks.

    In Section II. GC Conditions, Derivatization, and Mass Spectral Interpretation of Specific Compound Types (Chapter 7, Chapter 8, Chapter 9, Chapter 10, Chapter 11, Chapter 12, Chapter 13, Chapter 14, Chapter 15, Chapter 16, Chapter 17, Chapter 18, Chapter 19, Chapter 20, Chapter 21, Chapter 22, Chapter 23, Chapter 24, Chapter 25, Chapter 26, Chapter 27, Chapter 28, Chapter 29, Chapter 30, Chapter 31, Chapter 32, Chapter 33, Chapter 34, Chapter 35 and Chapter 36), information pertaining to the use of packed columns has been eliminated due to the disuse of these columns and their replacement with PLOT (porous-layered open tubular) and WCOT (wall-coated open tubular) columns in the modern GC/MS laboratory. There is an overview of GC detectors included in Chapter 2 that should be useful for those considering the use of the gas chromatograph-mass spectrometer (GC-MS) for occasional GC applications. There are also some applications from which valuable information can be obtained by combining a selective GC detector with a mass spectrometer in a single analysis.

    Analytes are introduced to the ion source of the GC-MS in ways other than through a GC. These techniques are carefully detailed in Chapter 2 and Chapter 4 and their advantages and disadvantages are articulated.

    A good portion of the material in this book is tabular and should be used to gain information on how to perform an analysis of a specific sample category and then in the determination of the identity of the individual analytes. This is a book that should be both on the analyst’s desk and on the bench next to the instrument. The original edition did an excellent job of presenting the needed tools. This edition expands mainly on the narrative section of the original book and retains and updates those tabular data that were so helpful in the previous edition. At the same time, this edition expands on the techniques of mass spectral data interpretation. Chapter 3 is new and is relatively short because it covers the interface between the gas chromatograph and the mass spectrometer. Chapter 5 goes into more depth on the interpretation of mass spectra. Chapter 6 is a completely revised treatise on the use of GC/MS in the area of quantitation. The information in Section III. Appendices has been expanded and has more helpful tools for mass spectral interpretation. Additional general mass spectral interpretation information can also be found in the chapters on Specific Compound Types (Section II, Chapter 7, Chapter 8, Chapter 9, Chapter 10, Chapter 11, Chapter 12, Chapter 13, Chapter 14, Chapter 15, Chapter 16, Chapter 17, Chapter 18, Chapter 19, Chapter 20, Chapter 21, Chapter 22, Chapter 23, Chapter 24, Chapter 25, Chapter 26, Chapter 27, Chapter 28, Chapter 29, Chapter 30, Chapter 31, Chapter 32, Chapter 33, Chapter 34, Chapter 35 and Chapter 36).

    Much of the material contained in the GC Conditions, Derivatization, and Mass Spectral Interpretation of Specific Compound Types section of the first edition was from Fulton G. Kitson’s personal experiences in his 30-year career in GC and mass spectrometry. Much of this material has been retained, expanded, and its presentation somewhat modified; however, the existence of this material and the presentation style would not exist if it had not been from his experiences and efforts to organize it (Chapter 7, Chapter 8, Chapter 9, Chapter 10, Chapter 11, Chapter 12, Chapter 13, Chapter 14, Chapter 15, Chapter 16, Chapter 17, Chapter 18, Chapter 19, Chapter 20, Chapter 21, Chapter 22, Chapter 23, Chapter 24, Chapter 25, Chapter 26, Chapter 27, Chapter 28, Chapter 29, Chapter 30, Chapter 31, Chapter 32, Chapter 33, Chapter 34, Chapter 35 and Chapter 36 and several of the appendices).

    The number of appendices has been increased from 12 to 17. The appendix on Atomic Masses and Isotope Abundances has been expanded to provide tools to aid in the determination of an elemental composition from isotope peak intensity ratios. An appendix with examples on Steps to Follow in the Determination of an Elemental Composition Based on Isotope Peak Intensity Ratios has been added. Appendices on whether to use GC/MS or LC/MS; third-party software for use in data analysis; a list of information required in reporting GC/MS data; X+1 and X+2 peak relative intensities based on the number of atoms of carbon in an ion; and a list of available EI mass spectral databases have been added. Others such as the ones on derivatization; isotope peak patterns for ions with Cl and/or Br; terms used in GC and in mass spectrometry; and tips on setting up, maintaining, and troubleshooting a GC have all been expanded and updated as has the appendix on maintenance and troubleshooting problems in the mass spectrometer.

    Since the first commercial GC/MS system was introduced in the mid-1960s by the Swedish company LKB, a number of GC and GC/MS companies have emerged only to be merged into larger companies, acquire and lose their brand identity, or just fade into the pages of scientific instrument history. In late 2009, Agilent Technologies (the noncomputer/nonprinter part of Hewlett–Packard), which was spun off in the last part of the 20th century, announced that it was acquiring Varian, Inc., which itself was a scientific multiproduct-line company that was part of an earlier breakup of Varian, Corp. In addition to vacuum technology, laboratory spectroscopy instruments (near-IR, UV-vis, atomic absorption, and inductively coupled emission spectroscopy), nuclear magnetic resonance spectroscopy, and superconducting magnets, Varian was a major provider of GC and GC/MS instruments (with the internal ionization quadrupole ion trap (QIT) technology acquired from the then Finnigan Corp. in 1989). Varian also was a manufacturer of tandem quadrupole MS/MS instruments used in GC/MS and LC/MS. The GC business (instruments and supplies) and the ICPMS and tandem quadrupole products of the two companies were considered to be too similar, and the European Economic Community (EEC) requested that Agilent divest itself of these areas before the acquisition could go forward.

    Bruker Corporation (headquartered in Billerica, Massachusetts, and the publicly traded parent company of Bruker Scientific Instruments Division (Bruker AXS, Bruker BioSpin, Bruker Daltonics, and Bruker Optics) and Bruker Energy & Supercon Technologies Division) acquired ICPMS instruments, laboratory GC instruments, and GC/MS tandem quadrupole instruments businesses of Varian from Agilent Technologies. The three acquired product lines will form the core offerings in a newly established Bruker Chemical Analysis Division. Unfortunately, this divestiture will not retain the Varian company or product name. Agilent was not required to divest itself of the Varian internal ionization QIT GC/MS technology, and Varian is the only company currently offering such an instrument commercially. Even if Agilent continues the QIT GC/MS product line (which is very likely), the Varian name will no longer be used. Throughout this book, reference is made to Varian GC, QIT, and tandem quadrupole GC/MS technology. Because of these Agilent and Bruker acquisitions, the name Varian, with respect to analytical instrumentation, will be a total unknown to practitioners entering the field in 5 years. This is why we felt this explanation was necessary. The industry will change, but the information in the book will still be valid and usable.

    A very good source for peer support regarding GC and GC/MS is the Chromatography Forum at http://www.chromforum.org.

    Acknowledgments

    The greatest thanks for the aid in the preparation of this book go to the three authors of the first edition: Fulton G. Kitson, Barbara S. Larsen, and Charles N. McEwen. Fulton Kitson’s desire to share his many years of experience performing GC/MS analyses in a way that he felt would be most useful to new and experienced practitioners was carefully retained in this edition with expansion where necessary. Many people kindly provided information, encouragement, and assistance in the preparation of this book. Both of the current authors are grateful to Joan A. Sparkman, ODS’s wife, for her efforts in editing and organizing the manuscript for consistency of style. Just as ODS’s other three books have been all the better for her efforts, so will this one.

    ZEP would like to acknowledge and give special thanks to the following:

    Hal Bellows, formerly of Varian, Inc., and Valco Instruments for providing information on valves for GC and GC/MS and the thermal conductivity detector.

    Professor Aviv Amirav of Tel Aviv University for being very helpful in responding to questions on the pulsed-flame photometric detector and the DSI (direct sample interface), both of which he developed.

    Thomas Wampler of CDS Analytical, Inc., for providing helpful information on pyrolysis GC and the PyroProbe.

    ODS wishes to offer thanks to his graduate student, Matthew E. Curtis, who assisted in the acquisition of some of the spectra and spent time proofing Appendix Q. He also wishes to express thanks to his colleague, Patrick R. Jones, at the Pacific Mass Spectrometry Facility in the University of the Pacific for his encouragement and reading of some parts of the manuscript. As with his other books, ODS must also express thanks to his two canine mass spectrometrists, Maggie and Chili, who were constantly looking over his shoulder to make sure things were being properly done.

    Both authors acknowledge the support of the National Institute of Standards and Technology for their permission to use spectra from the NIST08 Mass Spectral Database (NIST08).

    Chapter 1. Introduction and History

    Gas chromatography/mass spectrometry (GC/MS) is the most ubiquitous analytical technique for the identification and quantitation of organic substances in complex matrices. The gas chromatograph-mass spectrometer (GC-MS) is indispensable in the fields of environmental science, forensics, health care, medical and biological research, health and safety, the flavor and fragrances industry, food safety, packaging, and many others. The instrumentation ranges in price from nearly 1 million dollars to just a few thousand. The size is large enough to require a 4-m×4-m room to that of an average briefcase (Figure 1.1).

    GC/MS is the synergistic combination of two powerful microanalytical techniques. The gas chromatograph separates the components of a mixture in time, and the mass spectrometer provides information that aids in the structural identification of each component. This combination has several advantages [1]. First, it separates components of a complex mixture so that mass spectra of individual compounds can be obtained for qualitative purposes; second, it can provide quantitative information on these same compounds. Mass spectrometry ionization techniques that require gas-phase analytes are ideally suited to GC/MS because sample volatility is a requirement of gas chromatography (GC). The gas chromatograph, the mass spectrometer, and the interface linking these two instruments are described in the following chapters.

    GC/MS can provide a complete mass spectrum from a few femtomoles of an analyte; ideally, this spectrum gives direct evidence for the nominal mass and provides a characteristic fragmentation pattern or chemical fingerprint that can be used as the basis for identification along with the gas chromatograph retention time.

    Mass spectrometry had its origin ca. late 1800s with the work of John Joseph Thomson [2] and Wilhelm (Willy) Carl Werner Otto Fritz Franz Wien [3]. Mass spectrometry was dominated by the measurement of the various nuclides * that made up the known elements of the time until the mid-part of the 20th century when the mass spectrometer’s use for the analysis of petroleum products and other organic compounds began to gain momentum.

    *A nuclide is an atomic species characterized by the total number of neutrons and protons in the nucleus. Although not synonymous with isotope, for the purposes of this book, a nuclide is one of the many atomic species that are characterized by both their atomic number and their mass number.

    Chromatography began about the same time as mass spectrometry (ca. 1900) with the seminal publication by Mikhail Semenovich Tsvet (two other papers appeared in German that are often mistakenly referenced as the beginning of chromatography: Tswett MS) 4.5.6. and 7.. The early practice of chromatography consisted of the application of liquid samples to short homemade columns of various absorbents or to absorbent paper. The report of partition chromatography by Archer John Porter Martin and Richard Laurence Millington Synge 8. and 9. in 1941 led to the development of GC by Martin and Anthony Tarfford James 10. and 11. in 1950.

    Very soon after the development of GC, attempts to interface the gas chromatograph with the mass spectrometer began. This was a natural development as the gas chromatograph separates organic compounds, and they eluted from the column in a purified state in the gas phase; and the mass spectrometers of that time required pure gas-phase analytes for ionization. However, the original gas chromatographs used packed columns with flow rates (20–30mLmin−1) that overwhelmed the required low pressures of the mass spectrometer. One of the main obstacles to the technique of GC/MS was this incompatibility in pressure requirements. Today’s instrumentation is faced with far fewer such problems because of the use of capillary columns with flow rates that are usually 1.5mLmin−1 or less, and much better pumping systems to maintain the vacuum required for the mass spectrometer.

    As will be forever debated, the actual first attempt to interface the gas chromatograph and the mass spectrometer was accomplished by either Joseph C. Holmes and Francis A. Morrell at Philip Morris, Inc., in Richmond, Virginia, who published their work on the interfacing of a gas chromatograph with a Consolidated Engineering Corporation (CEC) Model 21-103B magnetic-sector mass spectrometer in 1957 [12] or Roland S. Gohlke and Fred McLafferty (both at Dow Chemical Company in Midland, Michigan, at that time) who presented their work on interfacing a gas chromatograph with a time-of-flight (TOF) mass spectrometer at the 129th National American Chemical Society (ACS) meeting in April of 1956 in a symposium on Vapor Phase Chromatography[13]. This work was first published in a paper authored only by Gohlke in the April 1959 issue of Analytical Chemistry, almost a year after it was received by the journal on May 31, 1958 [14] and almost 3 years after the 129th ACS meeting. The Holmes/Morrell work was first presented at the Fourth Annual Meeting of American Society for Testing and Materials (ASTM) Committee E-14 on Mass Spectrometry and Allied Topics in Cincinnati, Ohio, in May of 1956.

    The GC-MS of today is a unique instrument. Gohlke/McLafferty and Holmes/Morrell treated their systems as a gas chromatograph being used as an inlet to a mass spectrometer; there are some who would treat the mass spectrometer as a detector for the gas chromatograph. Neither of these is true. The mass spectrometer is not a gas chromatograph detector, and the gas chromatograph is not an inlet for the mass spectrometer. It is important to remember that GC/MS is as different from either GC or mass spectrometry as GC and mass spectrometry are from one another. This is because an elevated pressure is required to separate the components of a mixture in a gas chromatograph and a greatly reduced pressure is required to separate the ions of various mass-to-charge ratios (m/z values) that characterize a pure component of that mixture.

    Both the Gohlke/McLafferty and the Holmes/Morrell attempts at interfacing the gas chromatograph and the mass spectrometer involved splitting a small portion of the gas chromatograph eluate to the mass spectrometer, with the remainder being diverted to either a conventional gas chromatograph detector or the atmosphere. This was necessary to circumvent the conflicting high-/low-pressure needs of the two instruments. In the 1960s, devices were developed to enrich the eluate from packed gas chromatograph columns with respect to the analyte. These devices, for the most part, have now fallen into disuse because of the use of capillary gas chromatograph columns that produce eluates much richer in analyte concentration than packed columns and improved vacuum systems. Today’s modern instrument has the exit end of the gas chromatograph column placed directly in the ion source of the mass spectrometer.

    A very significant factor in the evolution of GC/MS was the development of data systems. When GC/MS was first being explored, it was readily seen that the potential for the volume of data was overwhelming. A 10-minute chromatographic run, acquiring spectra at the rate of one per second, would result in a total of 600 spectra. Extracting the spectra associated with various chromatographic peaks and then dealing with the presence of mass spectral peaks that were due to background associated with the sample or the gas chromatograph column was quite daunting. * It was not until the development and commercialization of the minicomputer (ca. 1965) that it was possible to bring the computer to the GC-MS. Before that time, the data had to be brought from the mass spectrometer to the computer and input manually. When Digital Equipment Corp. (acquired by Compaq Computer, which was then acquired by Hewlett–Packard) introduced the first commercial minicomputer, the PDP-8, one of its first uses was to acquire and process GC/MS data 15. and 16.. Users quickly warmed to the abilities and speeds of these computers. As the minicomputer evolved, the speeds began to fade because of the overhead of the operating systems and software used to develop the GC/MS applications. As the speed of the second-generation individual computer (the microcomputer) continued to increase, the speed of the early 1970s GC/MS data systems was once again realized near the end of the 1990s.

    *The term peak has already been used twice in this paragraph: once referring to the chromatographic peak and once referring to the mass spectral peak. This is an excellent example why it is always important to identify the type of peak being discussed when GC/MS is involved. In GC/MS, the word peak should never be used unless it is preceded by chromatographic or mass spectral.

    Improvements in capillary column injectors 17.18.19. and 20., development of fused silica capillary columns [21], development of electronic flow and pressure control [22] and improvements in the bleed characteristics of open-tubular wall-coated columns [22] have led to easier-to-use GC/MS systems with lower and lower limits of detection. Improvements in gas chromatograph column stability, controlled rapid heating rates for fast chromatography, and reduced oven cool-down times have also partially contributed to the technique.

    The GC/MS instrument of today allows for more flexibility in ionization, speed of data acquisition, and ease of use for less-skilled practitioners who are more interested in answers than the art and science of the technique, and, very importantly, much smaller size. The GC/MS floor-standing instrumentation of the 1970s and early 1980s would fill a 10-m×10-m room. Some of today’s laboratory instrumentation can be accommodated by 2–4 square feet of benchtop space.

    GC/MS is limited to analytes that are not only volatile and thermally labile but can also withstand the harsh partitioning conditions of the gas chromatograph. * Even with this limitation, there are many analytes that can only be separated from complex mixtures and identified by GC/MS. Compounds that exist only in the gas phase at temperatures below 100°C cannot be separated and ionized using techniques other than GC/MS. Due to the ability to form stable, volatile derivatives of many compounds not suited for GC/MS in their natural forms, the number of possible analytes can be significantly expanded. Because of the extensive fragmentation experienced during electron ionization (EI), it is the most widely used GC/MS ionization technique; there are many compounds that produce unique patterns that can be used in conjunction with gas chromatographic retention-time data for an unambiguous identification.

    *Compounds that can be ionized by atmospheric pressure chemical ionization (APCI) used in combination with LC/MS must be volatile and nonlabile-like compounds analyzed by using GC/MS; however, in LC/MS, the analytes do not have to withstand the rigors of the gas chromatographic partitioning process. Therefore, the range of analytes for APCI LC/MS can be expanded in the direction of lack of volatility and thermal lability.

    Limits of detection can be lowered using special data acquisition techniques such as selected ion monitoring (SIM). ** Three-ion ratios can be used for unambiguous identification because of extensive fragmentation when SIM is employed [23]. *** Formation of electrophilic derivatives through the use of reagents such as perfluoropropionic anhydride allows limits of detection to be greatly reduced in the presence of complex matrices due to the ability to take advantage of techniques such as electron capture/resonance ionization.

    **In many cases, spectral acquisition of GC/MS data involves a contiguous range of m/z values recording any ion abundances at any m/z value in the range. Instruments such as the transmission quadrupole mass spectrometer can be operated where each acquisition cycle of the instrument measures the ion current for a few (usually less than 8) m/z values by jumping from value to value and spending a specified dwell time on each ion to measure its ion current (abundance). This technique is called selected ion monitoring (SIM).

    ***Three-ion ratios can also be used with full-spectrum acquisition methods. Although it may not appear to be necessary to use these ratios when a complete spectrum is generated by full-spectrum acquisition, the three-ion ratio is required in some regulated methods, such as screening for drugs of abuse.

    Figure 1.2 is a conceptual illustration of the GC-MS. There are a number of variables associated with a GC/MS analysis. These variables fall broadly into two categories—instrumental variables and operational variables. For the most part, the instrumental variable must be decided before the actual GC-MS is acquired. The operational variables are those decided for each specific analysis.

    1.1. Instrumental Variables

    • Automation (requiring some type of autosampler).

    • Type of sample introduction(s)—e.g., type of gas chromatograph injector, direct introduction, pyrolysis, gas sampling valves, etc. If subambient cooling is required, will it be CO2 or LN2?

    • Gas chromatograph oven-temperature requirements—e.g., subambient cooling (CO2 or LN2 option), rapid temperature ramping, minimal cool-down times, etc.

    • Requirement (if any) for conventional gas chromatograph detection.

    • Gas chromatographic mobile phase to be used.

    • Type of mass spectral ionization—e.g., EI, chemical ionization (CI), field ionization (FI), electron capture negative ionization (ECNI), etc.

    • Type of m/z analyzer—this is based on data requirements such as mass accuracy, spectral acquisition rate, lower limits of detection, linearity for quantitation, etc.

    • Data system requirements—e.g., analysis reporting, database searching, automated quantitation, accurate mass from integer data, etc.

    Some of these instrument variables can be added after the purchase and installation of the initial instrument, like software items; others such as analyzer and ionization types are not changeable. The same could be true for the sample introduction types and oven-temperature requirements. This is why a careful needs analysis should be performed before the instrument is purchased.

    1.2. Operational Variables

    • Gas chromatograph column to be used—e.g., length, diameter, stationary phase, thickness of stationary phase, etc.

    • Injector settings—e.g., temperature, split ratios, split times, etc.

    • Need for flow-rate adjustment to obtain proper linear velocity of mobile phase.

    • Calibration of m/z scale.

    • Gas chromatograph oven-temperature program rate(s)—e.g., initial hold time and temperature, temperature ramp(s), upper temperature and hold time, cool-down time, etc.

    • Temperature of interface between gas chromatograph and mass spectrometer.

    • Temperature of ion source and analyzer.

    • Type of ionization—e.g., EI, CI, FI (may require hardware change and introduction of an auxiliary gas).

    m/z range to be acquired.

    • Rate of spectral acquisition (may involve stating number of spectra to be averaged before storing data).

    • Spectral acquisition type (centroid [default] or profile) based on instrument type.

    The various gas chromatograph sample inlets, sample introduction methods, columns, GC detectors, and operating conditions are described in Chapter 2. The reason the gas chromatograph mobile phase, column size, and ionization type need to be known at the time of an instrument purchase is that this has bearing on the pumping system required for the m/z analyzer. This will be explained in more detail in Chapter 4.

    GC involves a lot more than just selecting an appropriate column length, diameter, and stationary phase. With modern open-tubular columns, sample injection has become as significant as the column selection. As detailed in Chapter 2, there are several different types of injectors; the most widely used injector is the so-called split/splitless injector used for a spilt or a splitless injection. Analytes are usually present in a solvent. Selection of the solvent, again, is as important as the column selection. Even though GC conditions are provided for many types of individual compounds in Section II, there are many analyses that require the determination of multiple types of compounds at the same time. For this reason and others, GC/MS is an experimental science. More often than not, an analysis must be developed. The chromatographic and data acquisition must be determined empirically.

    The most widely used ionization technique in GC/MS is EI. Probably greater than 90% of all GC/MS analyses are performed using EI. Many instruments require a physical change in the ion source when switching from one ionization technique to another. The internal ionization quadrupole ion trap (QIT) allows for EI and CI without any physical changes. Some manufacturers have combination EI/CI ion sources and others provide instructions for obtaining EI data from CI sources. FI is the least used GC/MS ionization technique and is only offered by two instrument manufacturers: Waters Corp. as a TOF and tandem quadrupole * instrument; and JEOL as a TOF GC/MS system. Another ionization technique that was available in the past for GC/MS is APCI. There are no commercial instruments offering this technique at this time. A paper was published with instructions on how to configure an atmospheric pressure ionization (API) instrument (mostly APCI and electrospray ionization (ESI) instruments used in liquid chromatography/mass spectrometry (LC/MS) to take the eluate from the gas chromatograph for APCI) [24].

    *Tandem quadrupole is a term used to describe an instrument used for mass spectrometry/mass spectrometry (MS/MS). This instrument is sometimes referred to as a tandem-in-space instrument, which means that ions from an initial ionization isolated by one mass spectrometer are activated in such a way as to bring about their subsequent decomposition. These ions produced by this decomposition of a precursor ion are then separated according to their m/z values, using a second m/z analyzer. The instrument is called a triple quadrupole because the two tandem QMF instruments are separated by a third device which brings about the collisional activation of the precursor ion. In the original design of this instrument, this third device was also a quadrupole operated in such a way as to be used only for collisional activation and not ion separation. Today, this third device is usually not a quadrupole but the name triple quadrupole remains.

    ECNI, also known as resonance electron capture negative ionization, is another somewhat widely used GC/MS technique because of the low detection limits that can be obtained for electrophilic compounds such as halogenated pesticides or halogenated derivatives. Due to the specificity of this technique, matrix compounds will not be detected for extremely low limits of quantitation, especially when used in conjunction with an SIM analysis.

    GC/MS has used many types of m/z analyzers to separate ions according to their m/z values. The device that is the most ubiquitous in GC/MS instrumentation is the transmission quadrupole analyzer also known as the quadrupole mass filter (QMF). The device that follows this in popularity is the QIT. Both of these devices are limited to producing data with an integer m/z value. Such data does not produce unambiguous elemental composition for ions. However, an accurate mass measurement, within±0.1 millimass units, does provide an unambiguous elemental composition. This has led to an increased popularity of the reflectron TOF analyzer, which will generate such data. The TOF provides lower detection limits than can be achieved with the QMF analyzer and does not produce skewed spectra due to spectral acquisitions occurring during rapid changes in the concentration of the analyte in the ion source due to the chromatographic peak width. The TOF analyzer will acquire spectra at a faster rate than can be achieved with any other type of analyzer. Software has been developed that allows for the assignment of accurate m/z values to QMF and QIT data through the use of mass spectral peaks of known purity and known exact m/z values, which has expanded the utility of these instruments.

    Magnetic-/electric-sector instruments (the double-focusing mass spectrometer), along with magnetic-sector (single-focusing) instruments that dominated mass spectrometry until the commercialization of the QMF by Finnigan Corp. (now Thermo Scientific of Thermo Fisher), Hewlett–Packard (the analytical instrument division of HP is now part of Agilent Technologies), and Extranuclear Corporation (Extrel CMS, LLC) in the late 1960s and early 1970s, are still in limited use and commercially available from at least three different manufacturers.

    GC/MS/MS (also known as tandem mass spectrometry) is another technique that is being increasingly employed for various types of analyses and will be discussed in more detail in Chapter 4. GC/MS/MS is commercially limited to the use of the triple quadrupole instrument (tandem-in-space) and to the QIT systems (tandem-in-time). Although commercially available, the Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (the magnetic ion trap) has also been used for GC/MS. These instruments are capable of very accurate mass measurements; but due to their complex operation, need for a cryogenically cooled superconducting magnet, and high initial cost, they are rarely found in a GC/MS laboratory.

    GC/MS presents a paradox (Figure 1.3). As GC has developed, the width of the chromatographic peak has continually been reduced; i.e., the elution time for a component has become less. Acquisition of a mass spectrum from a scanning beam-type instrument (the QMF and the double-focusing sector instrument) is obtained over a finite period. Narrow chromatographic peaks result in rapid changes of analyte concentration in the ion source during the acquisition of a single spectrum. This spectrum can exhibit a skew (relative intensities of peaks at different m/z values that are different from what would be observed if there was no change in concentration in the ion source during the spectral acquisition). This skew will not be that reproducible and will make searches against standard mass spectral databases difficult. Shorter acquisition time can reduce the spectral skewing; however, the quality of the spectrum can deteriorate because the time spent measuring the ion current for any single m/z is so short that there is such a poor signal-to-noise ratio that the spectrum is uninterpretable. Reducing the period of elution for the analyte from the gas chromatograph column would greatly reduce the chromatographic resolution (the peak capacity). This reduced elution period would also have a tendency to increase the analysis; and with the current interest in fast GC to shorten analysis times, this would not be acceptable. Instrument companies are offering QMF m/z analyzers with shorter scan time by reducing the noise, but the minimal signal will remain the same. This paradox, in part, is the reason that there is an increased interest in the pulsed instruments such as the QIT and TOF.

    New practitioners enter the field of GC/MS; and, like all newcomers, they lack the experience needed to do many of the tricks that come with time spent in developing methods and interpreting data. This book should make that path to gaining the experience and knowledge easier and aid in resolving some of the various paradoxes that will be encountered.

    References

    1. J. Abian, The coupling of gas and liquid chromatography with MS, J. Mass Spectrom.34 (1999) 157; –68.

    2. J.J. Thomson, On the masses of the ions in gas at low pressure, Lond. Edinb. Dublin Philos. Mag.48 (1899) 547; –67.

    3. W. Wien, Untersuchungen über die elektrische Entadung in verdünnten Gasen, Annalen der Physik und Chemie65 (1898) 440; –52.

    4. M.S. Tsvet, A new category of adsorption phenome and its application to biochemical analysis, Travl. Soc. Naturalistes Varisovic, 14 (Russian) (1903); (Mswett—German Transcription of the name).

    5. M.S. Tsvet, Tswett centenary issue, J. Chromatogr.73 (2) (1972) 303; (Mswett—German Transcription of the name).

    6. M.S. Tsvet, Ber. Deut. Bot. Ges.24 (1906) 316, 384; (Mswett—German Transcription of the name).

    7. M.S. Tswett, Les Chromophless Dans Le Monde Végétal et Animal. (1910) Varsovie (French), Paris.

    8. A. Martin, R.A. Synge, New form of chromatography employing two liquid phases. I. A theory of chromatography. II. Applications to the microdetermination the higher monoamino acids in proteins, Biochem. J.35 (1941) 1358; –68.

    9. A. Martin, R.A. Synge, Separation of the higher monoamino acids by counter-current liquid-liquid extraction: the amino acid composition of wool, Biochem. J.35 (1941) 91–121.

    10. A.T. James, A.J.P. Martin, Liquid-gas partition chromatography, Biochem. J. Proc.48 (1951) VII.

    11. A.T. James, A.J.P. Martin, Gas liquid partition chromatography: a technique for the analysis of volatile material, Analyst77 (1952) 915; –32.

    12. J. Holmes, F. Morrell, Oscillographic mass spectrometric monitoring of gas chromatography, Appl. Spectrosc.11 (1957) 86–87.

    13. R.S. Gohlke, F.W. McLafferty, Early GC-MS, J. Am. Soc. Mass Spectrom.4 (1993) 367; –71.

    14. R. Gohlke, Time-of flight mass spectrometry and gas liquid partition chromatography, Anal. Chem.31 (1959) 535; –41.

    15. W.E. Reynolds, V.A. Bacon, J.C. Bridges, T.C. Coburn, B. Halpern, J. Lederberg, E.C. Levinthal, E. Steed, R.B. Tucker, A computer operated mass spectrometry system, Anal. Chem.42 (1970) 1122; –9.

    16. C.C. Sweeley, B.D. Ray, W.I. Wood, J.F. Holland, On-line digital computer system for high-speed single focusing mass spectrometry, Anal. Chem.42 (1970) 1505; –16.

    17. D.H. Desty, A. Goldrup, B.A.F. Whyman, The potentialities of coated capillary columns for gas chromatography in the petroleum industry, J. Inst. Petro.45 (1959) 287; –98.

    18. G. Schomburg, Sampling systems in capillary chromatography, In: (Editor: R.E. Kaiser) Proceedings of the Fourth International Symposium on Capillary Chromatography (1981) Huethig, Heidelburg, Germany, pp. 371–404.

    19. A. Zlatkis, J.Q. Walker, Direct sample introduction for large bore capillary columns in gas chromatography, J. Gas Chromatogr.1 (5) (1963) 9–11.

    20. K. Grob, K. Grob Jr., On-column injection onto glass capillary columns, J. Chromatogr. A.151 (21) (1978) 311; –20.

    21. R.D. Dandeneau, E.H. Zerenner, An investigation of glasses for capillary chromatography, J. High. Res. Chromatogr.2 (6) (1979) 351; –6.

    22. K.D. Bartle, P. Myers, History of gas chromatography, Trends Anal. Chem.21 (9.10) (2002) 547; –57.

    23. J.A. Sphon, Use of mass spectrometry for confirmation of animal drug residues, J. Assoc. Off. Anal. Chem.81 (5) (1978) 1247; –52.

    24. C.N. McEwen, R.G. McKay, A combination atmospheric pressure LC/MS-GC/MS ion source: advantages of dual AP-LC/MS:GC/MS instrumentation, J. Am. Soc. Mass Spectrom.16 (11) (2005) 1730; –8.

    Chapter 2. Gas Chromatography

    2.1. Overview of a Gas Chromatograph

    The technique of gas chromatography (GC) was introduced by James and Martin in 1952 [1]. The basic operating principle of GC involves volatilization of the sample in a heated inlet or injector of a gas chromatograph, followed by separation of the components of the mixture in a specially prepared column. Only those compounds that can be vaporized without decomposition are suitable for GC analysis. These compounds include most solvents and pesticides, numerous components in flavors, essential oils, hydrocarbon fuels, and many drugs. Acids, amino acids, amines, amides, nonvolatile drugs, saccharides, and steroids are among the compound classes that frequently require derivatization to increase their volatility. (See Appendix G for more information on derivatization of compounds for analysis by gas chromatography/mass spectrometry (GC/MS).

    A carrier gas (sometimes referred to as the mobile phase), usually hydrogen or helium, is used to transfer the sample from the injector, through the column, and into a detector or mass spectrometer. The vast majority of columns used today are capillary tubes with a stationary phase coated on the inner wall. Separation of components is determined by the distribution (partitioning) of each component between the mobile phase (carrier gas) and the stationary phase. A component that spends little time in the stationary phase will elute quickly. After elution from the column, each component still in the carrier gas flows into a detector or a mass spectrometer. Detectors are dedicated tools designed specifically for use on a gas chromatograph; examples are thermal conductivity (TCD), flame ionization (FID), nitrogen–phosphorus (NPD), flame photometric (FPD), and electron capture (ECD). A mass spectrometer is a complex instrument that can be used with or without prior separation by a chromatographic instrument such as a gas chromatograph.

    Key features of gas chromatographs are separate ovens that heat the individual injectors, the column, each detector, and the transfer line to the mass spectrometer. The column, and sometimes the injector ovens, allows the temperature to be increased at a regular rate (temperature programming) during the separation of the compounds in the sample. Figure 2.1 is a schematic representation of a gas chromatograph-mass spectrometer (GC-MS).