Sei sulla pagina 1di 76

SIU (signaling interface unit) V502

ZTE University IN Team

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Objectives

After this class, you should master: SIU structure the function of each board hardware connection

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Topics

system structure
single board hardware connection

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Basic concepts

board (single boards )located in slotsuch as MPDTI


DSNis minimum part, unit is made up of one or many boards fulfilling

certain function, such as DT, DSN,

modulemade up of a pair of standby/master MP and SP and other single boards.

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Structure

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Structure

Main control unit


Switch unit clock synchronization unit

DT unit

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DT unit

the digital trunk unit provides E1 interface to be connected with SSP. Every unit is a digital trunk board that can

provide 120 trunk circuits and 4 E1 interfaces. The board


is connected to NET board .

D T I

PCM0 PCM1 PCM2 PCM3

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DT unit

1 2 3 4 5 6 7 8 9 1 0 P O W B DD TT I I 1 2 D T I 3 D T I 4 D T I 5 D T I 6

1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 D T I 7 D T I 8 DD TT I I 9 1 0 D T I 1 1 D T I 1 2 D T I 1 3 D T I 1 4 D T I 1 5 D T I 1 6

2 2 6 7 P O W B

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Main control unit

1 2 3 4 5 6 7 8 9 10 11121314151617181920 21222324252627 P O W B S M E M M P M P C O M M 1 C O M M 2 C O M M 3 C O M M 4 C O M M 5 C S S S S S S P M O T T T T T T E O M B B B B B B P N M D I 6 P O W B

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Main control unit

MP

COMM

MONI

PEPD

Sub-unit

Other board

Room environment

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Main control unit

Ethernet MP NO.7 COMM MON NT Server

HDLC link T net

POWER SYCK DSNIFBI

DT

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Switch unit

2 3 4 5 6 7 8 9 1 1 0 1 P CS S D O KY Y S W I C C N B K K

1 1 2 3 DD S S NN I B C T L

1 1 1 1 1 1 2 2 4 5 6 7 8 9 0 1 DD D D D DD F S S S S S S S B NN N N N NN I I I I I I I I I I I I I I I B C T L

2 2 2 2 2 2 2 3 4 5 6 7 F P B O I W I B

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Switch unit

D S N

D S N

Perform timeslot switching function.


Working mode: master/standby.

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Switch unit

1 2 31

0 ... ...

63

T-net

62 61

32

8K8K T net 64 bidirectional HW 8Mb/s(128TS)

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

T net HW assignment

Message communication

0 1 2 3

20 21 22

4 5 6

Inter-module

Sub-unit

DSN(T-net)
18 19 60 61 62 63

standby Self-loop test

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

T net HW assignment
2MHW DS DS NI NI 4*8M DS DS NI 16*8M NI DSN DSN T net 2MHW 8M HW*16 COMM COMM 4 HWHW0-HW3 to COMM

COMM board

42 HWHW20-HW62 to functional unit


8M HW*16

DS 16*8M DS NI NI
10*8M DS DS NI NI 16*8M FB FB II

sub-unit
8M HW*10

To SNM or other module


8M HW*16

HW4-HW19 SNM or other

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

module

univ.zte.com.cn

clock synchronization unit

Function:
Received the reference clock from the superior exchange(DTI) or receive from BITS, and create

synchronous clock to other parts.

Including: 2 SYCK boards

1 CKI board

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

clock synchronization unit


MP
4MHz/8KHz

DTU D S N I SP) 8MHz/8KHz SYCK

COMM MON D S N 16MHz/8kHz External clock signal (DTI) BITS

D S N I (MP)

F B I

8MHz/16MHz/8KHz

CKI
univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

FBI sub unit

provides information channel between PSM and SNM


both for SNM and PSM side a pair of FBIwhich is master/standby, for SNM side, BFBI provides support for

FBIfor PSM side BNET backboard provides support for


FBI.

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Background network configuration(OMM)

NTNT Server Server

MP MP
TCP/IP NT Client NT Client ..
1

router

router

DDN PSTN/PSPDN

NT Client

NT Client

NT Client

NT Client

NT Client

NT Client

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Single board-MP

Functions: The heart of SIU.


Control T net connection Control the data and command transmission between

foreground and background.


Perform message communication with sub-unit. Control master/standby switchover

Provide Ethernet interface

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Single board-MP

Structure
RAM-64MB HD- 2GB or above

CPU- Intel 586


Provide interface of IDE, I/O, VGA

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Single board-MP

IP address distribution

1 1 0 A A A A A A A A A A - - - B B B B B B B B

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Single board-MP

The connection from MP to other boards


Clock of MP is provided by DSNI, two cables from DSNI directly to MP.

a 10M Ethernet cable from MP to HUB,used to


communicate with background

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Single board-MP

MP foreground configuration
\CONFIG: Stores the configuration information \VERSION: Stores the version information \DATA Saves subscriber data \DATA\TEMP the temporary for saving the foreground data files. \DATA\V0100 the main directory for the foreground data

files
\DATA\V0101: the backup directory for the foreground data files
ZTE University univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

Single board-MP

panel indicator run fault master

standby

The power of MP is independent , it is not controlled by the side power, if master/standby indicator is off, means

MP offline

strongly suggested: shut down the MP before pull it out.


univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

SMEM

Function:
SMEM is used by MP to serve as message switch channel and data backup, designed for instant switch

between master/backup MP.

Indicators: HL1: normalrunningindicator

HL2: fault indicator

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

COMM

Classification of function MP-MP communication MP-PP communication NO.7 signaling board V5 signaling board: for access network

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

COMM

MP-MP communication board


Used for inter-module communication Handle 8 modules message. (not used in single

module)
Position: slot 13/14(fixed), 17/18,19/20 (changeable). Working mode: Active/Standby

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

COMM

MP-PP communication board


Used for intra-module communication Control T network connection 8 pair of TSs

Function units message connection: 24 pair of TSs


Position: slot 15/16(fixed), 17/18, 19/20(changeable) Handle 32 TS

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

COMM

NO.7 signaling: Provide NO.7 Signaling Link


Each board can provide 16 links MAX.96 links in a PSM

Position: from right to left. 24,23

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

COMM

V5 signaling : Provide V5 signaling link


Each board can provide 16 links. Position: from right to left. 24,23

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

COMM

through semi permanent connection between COMM and


switch unit to communicate with MP

Semi permanent

..

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

COMM

256Kb/s MP COMM 256Kb/s DSN

MP

COMM

256Kb/s 256Kb/s

DSN

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

COMM

Indicator:
Run (green): Flash slowly Failure (red)

NO.7 signaling: Run light flashes quickly once the first


link is active. When COMM board is failure or has no data

configuration, failure indicator lights constantly or run


indicator flashes quickly.

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DTI

Function:
Interface between digital switching system and digital switching system or digital switching system and digital

transmission system.
Clock extracting and re-timing Frame /multi-frame synchronization

Control, detect and alarm

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DTI

Slot: Multiple of 3, insert 2 boards continuously Classification: DTI for CAS DTI for CCS DTI for connecting RSM DTI for connecting RSU

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DTI

1 DTI comprises 4 sub-unit(4 PCM) Indictors HL1: Running light HL2: Error light HL3: 1st PCM Running light HL4: 2nd PCM Running light HL5: 3rd PCM Running light HL6: 4th PCM Running light If the data of the sub-unit of DTI is not configured, The indicator light is dark, otherwise, it is constant illumination or blinking.

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

E1 interface of DTI

PCM of DTI

PCM of DTI

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

SYCK

SYCK (synchronization oscillator)


Function according to the reference clock to generate the

synchronous clock for MPM.


SYCK SYCK

Working mode:Active/standby
The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

SYCK

panel indicator
HL1normal HL3master HL2 fault HL4standby

HL5 Fast capturing mode

HL6 Tracking mode


HL7 Hold mode HL8free run mode

HL12manual select clock

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

SYCK

HL9 HL11select clock reference


indicates 1 and off indicates 0. 000 no reference

indicator. On

001~100
101

selected from four input


select reference from CKI

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

SYCK

Push button 1: Manual selection of clock reference. 2: Manual selection of clock reference enable. 3: Active/standby switchover button. 4: Reset button

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

CKI

clock interface

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSN

T-network
Function

structure

is time division non-blocking

switching network.

Voice connection switching intra and inter module


Connect the communication time slots of each function unit to COMM board through semi-permanent

connection.

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSN

Capacity
8K*8k time slots 64 bi-direction HWs

The rate of each HW is 8Mb/s(8 Mb/s,128 time slots)

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSN

Position Slot 10,12

Working mode Active /standby

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSN

Indicators Run (Green) Normal running, Slowly flash Failure (Red)

Active status (Green)


Standby status (Green)

When DSN is not startup or no data configuration, run indicator flashes quickly. When no clock or board is fault, the failure indicator is on. During the power on, run indicator flashes quickly- stop-flashes quickly- flashes slowly and regularly.

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSNI

Classification:
An interface of MP level (MP DSNI) DSNI-C An interface of SP level (SP DSNI) DSNI-S

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSNI

DSNI-C
Drives the various signals transmitted between MP and T network.

Converts 8Mb/s data stream to 2Mb/s..


A pair of DSNI boards handle 4 HWs. Distributes 4M and 8K clocks to COMM board

MPCOMM(MPPP)DSNI(C) T- Network

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSNI

DSNIS
Drives the various signals transmitted between SP and T network.

No data rate conversion


A pair of DSNI boards can handle 16 HWs. Distributes 8M and 8K clocks to COMM board.

SP DSNI(S) T- Network

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSNI

Position and working mode DSNI(MP level)

Slot 13/14
Working mode: Load-sharing DSNI(SP level) Slot 15/16,17/18,19/20 Working mode: Active/Standby

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSNI

HWs distribution of DSNI board


A pair of the DSNI board can handle 16 HWS 13/14 DSNI(C) 03HW

21/22 DSNI(FBI)
19/20 DSNI 17/18 DSNI 15/16 DSNI

419HW
2035HW 3651HW 5262HW

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

DSNI

Indicators Run (Green) Flash slowly Failure (Red) Active status (Green) Standby status (Green)

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

FBI

Function
It applies synchronous multiplexing technique and optical fiber technique to implement the

interconnections of Modules .
Connect to MON by RS485and by MON to MP Reduce connection wires and increase anti-

interference ability of the system.

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

FBI

Indicators HL1 normal

HL2fault
HL3master HL4standby HL5error code indicator HL6conference phone

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

PEPD

Function: Monitor the environment of the room: temperature/humidity smog (by many sensors) Reports different alarm types to MP in time Located in slot 25 in CTL layerthe communication mode is same with COMM, MON to MP

indicator HL1Run HL2fault

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

The Message Channel


SNM or other PSM
FBI C MP O M M DSNI
TNET HW0 to

HW3

DSNI
function unit

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Connection between DSN and COMM


1M HW0 HW1 1M HW2 1M HW3 HW4 1M HW5 ... 1M HW12 HW13 1M HW14 HW15 1M HW16 HW17 1M HW18 HW19 HW20 HW21 ... HW28 HW29 HW30 HW31

8M
HW0 HW0 HW1 HW1

COMM1 COMM2 COMM3 COMM4 COMM5 COMM6 ... COMM13 COMM14

8M

DSNI

DSNDSN
HW2 HW2 HW3

8M 8M

DSNI

HW3

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Connection between DSN and COMM


SLU
20 21

DSNI

COMM

2*HW SLU 2*HW


DSNI

COMM

HW20-35

SLU

D S netwo N HW36-51 rk HW0~3 I

16*2M COMM COMM

MP

1*HW
DTU 60 1*HW DTU ASIG 1*HW
DSNI

HW52-61
COMM

MP

61

FBI

COMM COMM univ.zte.com.cn

HW4-19

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

Message channel

Suppose: MP want to send message to DTI

The message path:


MPCOMM DSNICTL T network DSNIDTI

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Voice Channel
2*HW SLU
20 21

DSNI

2*HW SLU SLU 2*HW


DSNI

HW20-35

HW36-51 network
HW52-61

1*HW DTU
60

DSNI

1*HW

61

FBI

DTU
ASIG 1*HW

HW4-19
The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Voice Channel

Suppose one subscriber in one SLU call another


subscriber in another SLU, how is the voice channel between the two subscribers?

SP---DSNI---DSN(T-network)---DSNI---SP

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Hardware Cable Connection

1.
2.

Connection
Connection

between
between

T-net
T-net

and
and

function
control

units
layer

3. Other cables

1) Monitor cable
2) Clock cable 3) The connection of E1 of DTI

4) Background network connection

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Connection between T-net and function units


HW 0 3 1
P O W E R B

52 62 1 4 D S N I C T L 1 5 D S N I 1 6 D S N I ~

HW

36 51 1 7 D S N I 1 8 D S N I 1 9 D S N I ~

HW

20 35 2 0 D S N I 2 1 F B I ~

HW

HW 4

19 2 2 F B I 2 3 2 4 2 5 2 6
2 7 P O W E R B

3 C K I

4 S Y C K

7 S Y C K

1 0 D S N

1 1

1 2 D S N

1 3 D S N I C T L

Spc0,1 Spc2,3 Spc4,5 Spc6,7 Spc8,9 Spc10,11 Spc12,13 Spc14,15

Spc16,17 Spc18,19 Spc20,21 Spc22,23 Spc24,25 Spc26,27 Spc28,29 Spc30,31

Spc32,33 Spc34,35 Spc36,37 Spc38,39 Spc40,41 Spc42,43 Spc44,45 Spc46,47

Spc48,49 Spc50,51 Spc52,53 Spc54,55 Spc56,57 Spc58,59

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Connection between T-net and function units


DTI

6# DSNI-SP 5#

4#
Spc0,1 Spc2,3 Spc4,5 Spc6,7 Spc8,9 Spc10,11 Spc12,13 Spc14,15 Spc16,17 Spc18,19 Spc20,21 Spc22,23 Spc24,25 Spc26,27 Spc28,29 Spc30,31 Spc32,33 Spc34,35 Spc36,37 Spc38,39 Spc40,41 Spc42,43 Spc44,45 Spc46,47 Spc48,49 Spc50,51 Spc52,53 Spc54,55 Spc56,57 Spc58,59

SYCK

3#

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Connection between T-net and function units

The relation between HW and backboard HW4----SPC0 HW5----SPC1

HW62----SPC58

Connection explanationone cable transfers 2 HW and corresponding clock signal

The relation between HW and DSNI or FBI board HW4~HW19------------ 21 22 board

HW20~HW35---------- 19 20 board
HW36~HW51---------- 17 18 board HW52~HW62---------- 15 16 board
The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Connection between T-net and control layer

256Kb/s MP COMM 256Kb/s T-net

MP

COMM

256Kb/s 256Kb/s

T-net

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Connection between T-net and control layer


P O W E R B P O W E R B

S M E M C K I S Y C K

MP S Y C K

MP D S N D S N

M P M P
D S N I C T L

M P M P
D S N I C T L

M P P P D S N I

M P P P D S N I

M P P P D S N I

M P P P D S N I

M P P P D S N I

M P P P D S N I

S T B F B I

S T B F B I

S T B

V 5

P E P D

M O N I

P O W E R B P O W E R B

COMM12D1 COMM12D2

COMM11D1 COMM11D2

COMM4D1 COMM4D2

COMM3D1 COMM3D2

COMM2D1 COMM2D2

DSNI1-C

DSNI0-C
MPC O,2 MPC 4,6 MPC 8,10 MPC 12,14 MPC 16,18 MPC 20,22 MPC 24,26 MPC 28.30

MPC 1,3 MPC 5,7 MPC 9,11 MPC 13,15 MPC 17,19 MPC 21,23 MPC 25,27 MPC 29,31

DSN DSN COMM1 COMM0

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Connection between T-net and control layer

The relation between HW line and backboard


One HW line is divided into 8 1M HW. So totally 4 HW line can be divided into 32 1M HWrespectively

MPC0----MPC31
The first pair COMM board(13,14) ---- MPC03 The second pair COMM board(15,16)----MPC47

.
The sixth pair COMM board(23,24) ---- MPC2023

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Connection between T-net and control layer

Note
1.The COMM board in 1516 have lines connected to T net, why?

2.MPC 28---31 is connected with MP board directlywhy


3.25---26 board in control layer have no HW from switching network unit,why?

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Other cables

Monitor cable
485 monitor cableused to monitor board without HW power boardincluding P powerSYCK board

DSNIFBI and so on
RS232 cablemonitor built-in SDH Environment monitor cablePEPD boardmonitor

infraredsmoketemperature and humidity.

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Other cables
P PWR P 6# W R B P W 5# R B P 4# W R B P 3# W R B P 2# W R A P 1# W R A ZTE University BDT P W R B P W R B P M W O R N B P W R B P W R A P W R A L P PWR

R
in out6# In out 5# In 4# out In 3# out In 2# out 1# In out univ.zte.com.cn

In out
In out In out

458

BDT

BCTL

BNET

In 485 out In out

BSLC

BSLC

In out

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

Other cables
Clock cable
DTI

6# DSNI-SP 5#
MP2

Connect to HUB
MP1

4#
DSNI1-C
MPC 1,3 MPC 5,7 MPC 9,11 MPC 13,15 MPC 17,19 MPC 21,23 MPC 25,27 MPC 29,31

DSNI0-C

3#

MPC O,2 MPC 4,6 MPC 8,10 MPC 12,14 MPC 16,18 MPC 20,22 MPC 24,26 MPC 28.30

SYCK

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

The connection of E1 of DTI

4 PCM of the first DTI

4 PCM of the second DTI

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

univ.zte.com.cn

Background network connection

Warn panel

NT SEVER
ZTE University

CLIENT

CHARGEING SEVER
univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

Potrebbero piacerti anche