Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
COMPANY PROFILE
THE COMPANY IS ENGAGED IN :-
ECONOMISERS (GILLED/ FINNED TUBES) TUBE BENDING ON CNC BENDING MACHINE , TURN KEY PROJECTS IN WASTE HEAT RECOVERY WHERE KSB PUMPS, KSB VALVES, CONTROL VALVES, HP & LP HEATERS
CLIENT PROFILE
ATRIA POWER CORPORATION LTD.
PROBLEM STATEMENT:The Solar Steam Generator system is used to recover the heat from Hot Thermic Fluid coming from solar field in the form of superheated steam.
ADVATAGES Less expensive as compared to Plate type coolers Can be used in systems with higher operating temperatures and pressures Pressure drop across a tube cooler is less Tube leaks are easily located and plugged since pressure test is comparatively easy Tubular coolers in refrigeration system can act as receiver also. Using sacrificial anodes protects the whole cooling system against corrosion Tube coolers may be preferred for lubricating oil cooling because of the pressure differential
DISADVANTAGES Heat transfer efficiency is less compared to plate type cooler Cleaning and maintenance is difficult since a tube cooler requires enough clearance at one end to remove the tube nest Capacity of tube cooler cannot be increased. Requires more space in comparison to plate coolers
APPLICATION Industrial Process HVAC Air Processing Compressor Cooling Chemical Petrochemical: Processing & Refining Power & Electrical Generation Metals and Mining Refrigeration Pulp & Paper One of the most common applications is the cooling of Hydraulic Fluid and oil in engines, transmissions and hydraulic power packs. With the right choice of materials they can also be used to cool or heat other mediums, such as swimming pool water or charge air.
DESIGN
HEAT EXCHANGER CONSISTS OF : SHELL Design DISH END Design TUBE Design FLANGE Design NOZZLE Design
SPECIFICATION
Type of Boiler Natural circulation shell and tube heat exchanger. HTF side data Name of HTF fluid - Therminol VP1 HTF flow - 90000 Kg/hr HTF pressure at inlet - 12 Kg/cm HTF inlet temperature - 375C-Superheater, 359C-Evaporator, 258C-Economiser HTF outlet temperature -359C-Superheater, 257C-Evaporator, 228C-Economiser HTF max. pressure drop across the equipments - <4 Kg/cm
Water/Steam side data Steam flow at super heater Steam pressure at super heater outlet Steam temp. at super heater Feed water flow at Economiser Feed water pressure at Economiser inlet Feed water temp. at Economiser Blow down loss
11700 Kg/hr 35 Kg/cm at 355 C at outlet 12099.6 Kg/hr 39 Kg/cm at 130 C at inlet 400 kg/hr
Design codes Pressure parts Structural design Non pressure parts Equipments (I) Pvt. Ltd. Inspection Stage wise and final inspection Power Equipments (I) Pvt. Ltd. Final dispatch inspection required by the purchaser
MATERIAL OF CONSTRUCTION
Tubes Tube sheets Shell Baffle plates Saddle support Flanges Pipes Structural Gasketsa Wound SS304For Steam + Water CAF SA 210 Gr. A1 / Equivalent SA 266 Gr. 2/4 / Equivalent SA 516 Gr. 70 SA 516 Gr. 70 IS 2062 Gr. B SA 105 / SA 516 Gr. 70 SA 106 Gr. B IS 2062 Gr. B For Thermic Fluid Spiral
PROVE THAT CALCULATED PRESSURE IS HIGHER THAN DESIGN PRESSURE. WP = ((2 * f * ( t - c ) )/ (D - t + c)) =(5679.1713 / 16.95625 WP = 334.93085 kg/cm2 334.93085 kg/cm2 is > THAN 25 kg/cm2 HENCE SAFE
16 mm or 0.63 inch 636 mm or 25.04 inch 63 Kg/cm2 or 895.9 psi 0.762 mm or 0.03 inch 318 mm or 12.52 inch
HENCE SAFE
25 Kg/cm2 or 355.5 psi 1387 Kg/cm2 or 19723 psi 16 mm or 0.63 inch 636 mm or 25.04 inch 37.5 Kg/cm2 or 533.3 psi 0.762 mm or 0.03 inch 318 mm or 12.52 inch
WP = (23664.675 / 25.639305 ) WP = 922.98427 psi or 64.9075 Kg/cm2 WP = 64.907473 kg/cm2 is > THAN 25 kg/cm2 HENCE SAFE
42 Kg/cm2 or 597.2 psi 1387 Kg/cm2 or 19723 psi 16 mm or 0.63 inch 660 mm or 25.98 inch 63 Kg/cm2 or 895.9 psi 3 mm or 0.118 inch 1.02
HENCE SAFE
PROVE THAT TUBESHEET THK IS HIGHER THAN REQUIRMENT AS PER ABOVE CLAUSE
AS PER RCB 7.132 TEMA TUBESHEET FORMULA FOR BENDING t = (FG*[W P / *S ]^(1/2) )/ 3 WHERE WP WORKING TUBE SIDE PRESSURE F PARAMETER FOR UNSUPPORTED TUBESHEET T ACTUAL THICKNESS Ph HYDROTEST PRESSURE G PARAMETER FOR FIXED TUBESHEET WHICH IS SAME AS INSIDE SHELL DIA. d TUBE DIAMETER PITCH BETWEEN TUBES S CODE ALLOWABLE STRESS psi 1 - 0.907 FOR TRIANGULAR (P/d)2 PATTERN t = 1.7366325 = 1.7366325 inch or 44.11 mm t = 44.11 mm HENCE SELECTED 115 mm THK IS OK
25 Kg/cm2 or 355.5 psi 1.25 115 mm or 4.528 inch 37.5 Kg/cm or 2 533.3 psi 628 mm or 24.72 inch 19.05 mm or 0.75 inch 30 mm or 1.181 inch 1387 Kg/cm or 2 19723 psi 0.634
42 Kg/cm2 597.2 psi 1203 Kg/cm2 17110 psi 7.01 mm 0.276 inch 58.98 mm 2.322 inch 63 Kg/cm2 895.9 psi 0.762 mm 0.03 inch 29.49 mm 1.161 inch
42 Kg/cm or 2 597.2 psi 1203 Kg/cm or 2 17110 psi 5.54 mm or 0.218 inch 49.22 mm or 1.938 inch 63 Kg/cm2 or 895.9 psi 0.762 mm or 0.03 inch 24.61 mm or 0.969 inch