Aprobaciones

 UL o CUS para Estados Unidos


 CSA para Canada
 ATEX o CENELEC para Europa
 SAA para Australia
Certificado de Origen
Serie T
Sensor para altos flujos
Transmisores MVD
Tecnología MVD
Micro Motion Architecture – Sensors
 Sensors use 9-wire
cable with detection
in the transmitters

Long, expensive conduit runs

Where’s the problem?

Broken RTD?
All sensors work the same way
Best Diagnostic Coverage!

Process Sensor Core Transmitter System


Drive Overrange Drive coil failure EEPROM Power reset

Sensor temp max. EEPROM Cal factors not entered


Pickoff coil failure EEPROM DB
Core/Xmtr comms fail
Case temp max. EEPROM Totals RAM
RTD failure
Sen/core comms fail
Core temp max. EEPROM Program mA o/p sat
Sen. Not responding
Xmtr o/p failure
Den. Outside limits RAM mA o/p fixed
Xmtr warm-up
Slug flow Possible data loss Freq o/p sat
Sen type not entered
Flow overrange Freq o/p fixed
Burst mode
Event #1 trig
Cal. failure

New MVD Diagnostics Event #2 trig


Zero too low / high

Too noisy to zero


Current diagnostic
Elements of a Smart Sensor Installation

 Micro Motion 9-wire


Sensor
– New or Old
– Any Material
– D, Elite, R, F, T
– Any Size (D600
pending)
– Working Preferred!
Elements of a Smart Sensor Installation

 Core Processor
– Integral or Remote
– Holds Sensor Coefficients
– 18-30 volts DC
– 3 watts
– Modbus Output
Elements of a Smart Sensor Installation

 Signal Converter
– I.S. Barrier (except in safe
area)
– Local Display
– Wiring Terminals
– Outputs
MVD Sensors - What Information is
Available?

Primary variables
• Mass flow
• Volume flow
Enhanced density is a FUTURE
• Density RELEASE
• Temperature • Concentration
• Drive Gain • Standard Volume
• Net Solids
• API
• % Solids
• Corrected Density
Key MVD Transmitter Attributes
 Transmitter Flexibility (Compact Integral / Remote)
 Backward Compatibility
 Display for Zone1 / C1D1
 Fully stainless steel sensors
 4-wire cable
 Universal power supply AC/DC
 “MVD core processor” contains most parameters
 Limited reprogramming when replacing a Transmitter
 Display supports most start-up functions
 The most advanced Digital Coriolis transmitter line
Core Processor 4-Wire Interface MVD Sensor


4w
Power
Supply Drive

Signal Mini
Processing Pick-Off Barrier
Isolation Barrier RTD
Signal
Conditioning

Inputs/Outputs
Processing

Core Processor
Integrally or remotely mounted to the sensor
Model 1700/2700
Digitally processes raw signals from sensor
Transmitter
MVD Sensors - Exploded View
Cover

Ring

Puck Assy

Base

Feed thru
CORE PROCESSOR

New glass feedthrough


Gold plated Pins & Sockets
with tapped mounting hole Sockets with 4-finger contact
and alignment holes for easy Assembly with lubricant to prevent
fretting
core processor mounting
Core Processor

Model 3000

Local Operating Interface

Model 1700/2700 Model 2000


Model
Blind 1700
unit

Model 700
Core Processor Overview
Feature summary.
 4-wire interface (2-power, 2-communications).
Mounting Screw
 12 - 30 VDC input (17.3VDC for I.S.).
 RS-485 communications (modbus). Screw Terminals (4)
 Fully I.S. Design.
 Coriolis measurement.
 Flow, density, temp, ED, API, etc.
 Totalizer, cal factors.
 LED indicator.

Potting Shell
Transmitter Is a Modbus  ? Converter

 Foundation Fieldbus
 Profibus PA
 HART
 Modbus
 Analog Service Port: A temporary connection for
Diagnostics, Troubleshooting and Software
 Frequency Downloads… regardless of the installed output
board. The USP runs Modbus RTU, 38k baud.
 Discrete In/Out
Output and Power Supply Wiring Terminals
Three pairs of wiring terminals

Power Protection Flap


Prevents shocks to service
engineer when using Service Port

IP30 EExe Cover


Allows cover to be unscrewed
while unit is under power if the
output terminals are rated as
I.S.
Model 1700/2700 - LDO
Status LED (Tricolor)

STATUS

LCD
799.87456
Feedback LED FLOW
KG/H
SCROLL SELECT

Scroll Button Select Button

IR Receiver
Model 1700/2700 - Display Board (LDO)
 The display shows all process variables (or a selected subset)
 Flow totalizer can be started/stopped/reset Housing and display
 Multicolor status LED rotate up to 360 in
 Green - Normal Indication 90 steps.
 Yellow - Informational message
 Red - Critical alarm
 All basic startup functions are supported:
 Flow meter zero
 Output configuration
 Output simulation
 Communication settings
 Password security
 Certified Zone 1
 Two keys with an optical- feedback LED.
Model 1700/2700 - Display Board (LDO)
 Two LED indicators
– One multi-color LED for status:
Green - no alarm, normal operating mode
Flashing green - unacknowledged corrected condition
Yellow - acknowledged low severity alarm
Flashing yellow - unacknowledged low severity alarm
Red - acknowledged high severity alarm
Flashing red - unacknowledged high severity alarm
– One red LED for button confirmation
 NOT BACKLIT (future on enhanced display)
Moving to a Single Platform
So What Are the Details Behind Config
IO?

2 New Output Options


Model 1700
One mA; One frequency; RS-485

USP Address 111


Modbus 38.4k

Channel MAO1/HART
A Internal Power, 24v

Channel FO1
B Internal Power, 24v

RS-485
Channel
Modbus or HART
C
Model 1700
Intrinsically Safe: One mA; One frequency
Address 111
USP Modbus 38.4k

Channel MAO1/HART
A External Power

Channel FO1
B External Power

Channel
C
Model 1700 Output Assignments
Analog & IS Output Boards

Analog Output mA HART


Mass Flow Pv = Mass Flow
Volume Flow Volume Flow
API Corrected Volume Flow
Frequency Output Sv = Same as Pv
(follows the analog assignment) Tv = Same as Pv
Mass Flow Qv = Mass Flow
Volume Flow Volume Flow
Density
Display Capabilities Temperature
View Process Variables Drive Gain
View and Acknowledge Alarms External Pressure
Start, Stop, Reset Totalizers External Temperature
Perform Output Simulation Tests API Corrected Density
Change Measurement Units API Corrected Volume Flow
Assign Variables to Outputs API Corrected Volume Total
Scale Outputs API Corrected Volume Inventory
API Batch Avg Corrected Density
API Batch Avg Temperature
API CTL (table used)
Model 2700
One mA; One frequency
Address 111
USP Modbus 38.4k

Channel MAO1/HART
A Internal Power, 24v

Channel FO1 DO1


OR
B Internal Power, 24v Internal Power, 24v
or External Power or External Power

RS-485
Channel
Modbus or HART
C
Model 2700
Intrinsically Safe: Two mA; One frequency
Address 111
USP Modbus 38.4k

Channel MAO1/HART
A External Power

Channel FO1 DO1


OR
B External Power External Power

MA02
Channel
External Power
C
Model 2700 Output Assignments
Analog & IS Output Boards

Discrete Output
Analog Output FWD / REV
Mass Flow Event 1
Volume Flow Event 2
Density Event 1 or 2
Temperature Flow Switch
Drive Gain Zero In Progress
Corrected Density Fault
Corrected Volume Flow

Display Capabilities
Frequency Output View Process Variables
Mass Flow View and Acknowledge Alarms
Volume Flow Start, Stop, Reset Totalizers
Perform Output Simulation Tests
Change Measurement Units
Assign Variables to Outputs
Scale Outputs
Model 2700 Output Assignments
Analog & IS Output Boards

mA HART Sv = Same as Pv
Pv = Mass Flow
Tv = Mass flow
Volume Flow
Density Volume Flow
Temperature
API Corrected Volume Flow
Drive Gain
External Pressure Qv = Same as Pv plus
External Temperature
API Corrected Density Mass Total
API Corrected Volume Flow Mass Inventory
API Corrected Volume Total
API Corrected Volume Inventory Volume Total
API Batch Avg Corrected Density Volume Inventory
API Batch Avg Temperature
API CTL (table used)