Sei sulla pagina 1di 34

TELEMETRY

SOLUTIONS

Universal Monitors

One System
1
Mission Statement

We are dedicated to finding solutions


that are unique and innovative ,
creating Energy and/or Time Savings
for our valued customers.
2
3
Sewer Plant

Da
t
Ce a
n te
r

o ol
Sch
nk
n a
Li rne Cond
n ten te
SA In t .X
R
GP Apt
33
Cond. X Antenna
GPR
Apt 33 RF S
Internet Link

13

Remote measurement for high
9
11

m e n tr
y Water meter
RF
Ele oo
l

5
rise apartments or
7 Sc h

1
3
condominiums. 5
7

1 4
Cia
Saneamento
Da Y st
t
Ce a House
n te
r #3
GPRS

o ol
Sch
na nk
t en Li rne Y st
SA
n te
R In t House #3
GP
RF
Y st Antena
House #3 RF
Link
Internet

Meter Automation for


13

11
Homes y
9 e ntr
m l
Ele hoo
S c
7

3 Y st 7
House #3
1 5
RF

3
Water Meter
1 5
Sewer Plant
Company
Da Z
t
Ce a Meter #3
n te
r GPRS

o ol
Sch
a nk
ten
n Li rne
SA
n te
R In t
GP

Company Antenna
Z RF
Meter #3
Link
Internet
Commercial & Industrial
13

9
Customers
11

entr
y
m l
Ele hoo
7
Sc

3 7

1 5

1 6
nk
Li rne
te
In t

na
en
nt
SA
R
Company A
GP
SMS
Private Business

Hospital School 7
GSM/GPRS

Topology:
Individualized
Metering
Administrator
Internet Client

Mobile
Router
Operator
Router

Data Center
WMNET Center -Concentrator

Meters

Communication
Gas Water Web Server Protection
Server

Radio Frequence Transmission


EOS System
8
Serrinha Reservoir
EAT Pedro Ludovico

Activation of the
Serrinha
Reservoir Pumps

Serrinha Reservoir

9
Electrical Energy Metering

10
10
Full 2 Way Automation via WMNET Solution

11
Full 2 Way Automation via WMNET Solution

12 88
Change to Cubic Model - 1

13
Change to Cubic Model - 2

14
Change to Cubic Model - 3

15
Change to Cubic Model - 4

16
EOS + Cubic System Layout
WMNET RF

Water Meter thermostat

Cubic Cellular
Wi-Fi
Pressure Inferred Wi-Max
Ethernet

Pump Control Temperature

Energy measurement Relay

Motion Sensor Energy Metering

Example Devices 17
Electric - Selective Load shedding
Selective Load shedding
 Control meter disconnect
 Leave essential systems active
 Monitor usage during load
shedding periods for violators

EO
S
18
Electric - Load Limiting
Bronze Silver
Selective Load Limiting
 Set usage limits by category
 Auto disconnect when limit is breached Gold
 Leave essential systems at 100%
 Monitor usage during load shedding periods for
Bronze
violators

Gold

EOS Silver

Set Usage Levels


Gold Steel
Category Rated Usage Usage Limit
Gold 100A 100A
Silver
Silver 100A 100A
Bronze 100A 30A
Steel
Steel 400A 100A
Silver

19
Water - Measuring Line Loss
Measuring Line Loss
 Aggregation for water and
electric systems
 Account for line loss
 Full asset Management
 Peak Time and non peak
times defined

20
PRODUCT FAMILIES
Metering and Control Communication Module Electric Energy Metering
Module Module
M2M – Machine to
To any kind of
Machine
(Flow, Pressure, Temperature, etc.)
Communication
MCC - Transparent
- Up to 4 meters
- Analog Inputs transmission
- RS232c or 485 Telemetry;
- Digital Inputs
M2ME
- Digital Inputs
- Pulse Counters - Internal or
External modem - ABNT Standard
WMNET MC - GPRS Transmission M2MC
- AC Power Supply
Multiple Device Monitoring or Metering
Radio Frequence
Transmiter Telemetry
- Analog Inputs
- Collect data from Concentrator
- Digital inputs external devices - TACE Interface
- Pulse Counters - Collects information - Data Storage
- GPRS Transmission of MBUS Protocol - Terminal
- Internal Battery - Data Storage Consultation
WMNET WMNET
Supply WMNET RF - RF Transmissio - Cellphone
MCB Center
Trasmission

21 11
11
Benefits
Where to use our products:
 Oil and Gas fields ---Pipelines, station, wells, tanks…
 Pump stations --- tanks, pump controller, valve controls, meter reading
 Sewer lift stations --- Flow sensors, Motors, level sensors
 AMR --- Pulse meter interface, development needed for message type meters
 Factory monitoring ---- individual equipment Metering, energy savings, loss prevention
 Prison Facility --- water and energy savings, remote monitoring, HVAC Controls
 Other application --- The system is flexible enough to monitor anything with the correct sensor.
Mixing and matching the hardware will supply will bring solutions needed in the field

How is AAMS/ADTS different:


 Modularized hardware for customizing data output and inputs
 Equipment that can handle all environment or lack of AC or DC power
 Link all of our equipment wirelessly through our own proprietary mesh network.
 Each device is also a repeater for the next, building a stronger mesh
 Small radio modules that can be customized to monitor anything
 Pipeline monitoring of pressure, temperature and leaks by using the mesh network architecture
 Local PLC (Programmable Logic Control)
 Full range of hardware within one company umbrella
22
Micro Controllers
Metering and Control
Module Uses of this equipment:
To any kind of SCADA stands for supervisory control and data acquisition. It generally refers to
(Flow, Pressure, Temperature, etc.) industrial control systems: computer systems that monitor and control
industrial, infrastructure, or facility-based processes

- Analog Inputs Telemetry is a technology that allows remote measurement and reporting of
- Digital Inputs information. Systems that need external instructions and data to operate require
WMNET MC the counterpart of telemetry and telecom.
- Pulse Counters
- GPRS Transmission
- Electricty Supply
Summary:
Three devices that are primarily used in this application. They are basically the
same device in three different enclosures.
WMNET MB
- Analog Inputs 1. WMNET MC – Multi functional Micro Controller. Has several connection points
to monitor a broad range of devices.
- Digital inputs
2. WMNET MB – Smaller build of the WMNET MC and runs on a battery pack of
- Pulse Counters lithium batteries. No AC or DC power required
- GPRS Transmission 3. WMNET MCB – Fully Submersible model of the WMNET MB.
- Internal Battery
WMNET
Supply Key notes:
MCB
Each device can be linked together with an internal Mesh radio if they are within
communication distance. This way only one device can backhaul the information
of the group.

23 13
13
Multiple Device Monotring or Metering
Multiple Device Monotring or Metering
Radio Frequency
Transmiter Telemetry
- Collect data from Concentrator
external devices - TACE Interface
- Collects information - Data Storage
of MBUS Protocol - Terminal
- Data Storage Consultation
WMNET RF - RF Transmission WMNET - Cellphone
Center
Trasmission

Radio Frequency Telemetry


Transmitter Concentrator

Summary: Summary:
Individual radios can connect to each or multiple devices based Computer system that independently runs its own network of
upon the device interface. They will pass data or control the devices. This device can read meters and control valves based
device through two-way communications. The data is sent on preprogrammed parameters. It can also run a billing
through a 2.4 GHz mesh radio system to a Concentrator that system and print bills on site.
then backhauls the data to a central database.

Key notes:
Key notes:
Each WMNET Center can query a unit in its mesh via touch
Each radio has two communications to the device and to the screen commands. It can also control about 2,500 radio units.
mesh radio system. Each Concentrator can control up to about
2,500 radios.

24 14
14
Machine to Machine Controllers

Communication Module Summary:


M2M – Machine to These devices are used to take over machines within a network. We basically
Machine interface with the machine and then take control. The units connect to a WMNET
device or link through an RF module.
Communication
MCC - Transparent
transmission Key notes:
- RS232c or 485 We can interface into any machine and adjust the hardware connection if needed.
This device is commonly used to get more use out of older equipment by letting
- Internal or
the M2M device control it.
External modem
M2MC

25 15
15
Energy Metering

Electric Energy Metering


Module
Summary:
This device is used to monitor commercial electric meters. The data collected can
pass through the same WMNET network or be linked in through an RF radio.

Key notes:
Can handle up to 4 electric meters
M2ME

26 16
16
Individual Measurement System

RF Transmission Module
• Interfaces into most devices or sensors
• Collects data from devices with analog, MBUS, BACnet, WMNET
digital voltage or pulse generated by sensors or devices. RF
*more available
• Transmits data to devices for control or change of state.
• Stores data locally
• Transmits to any node in its mesh system
• Operates on 2.4 GHz or 902-928 MHz
• Repeater for other radios in its mesh system
• 10 year battery life

27 17
17
NEW for 2011 - CUBIC
Communication
Central Processor or Main Board • GPRS
3 Customizable Application boards • Ethernet
• Wi-Fi
Power board
Human-Machine interface
3 Application Boards
•analog
•Digital
•RS232C, RS485, MBUS,
Internal Web-Server
MACnet
txt or e-mail alerts •Relay
•PWM
straight from the Cubic
LED Display
to you. •Three-line text
•6 button analog keyboard
•Soft keys and soft menus
•Small graphic display
•XY capacitive touch screen

•16 MIPS low-power RISC Microprocessor


Concentrator
•Primary Battery 3.6 V •Controls up to 1064
•Power-over-Ethernet (PoE) EOS RF Modules
•USB powered (next revision)
•10 Year Battery Life

28 18
18
Additional Features
Demand Management / Load Control

System is managed by the usage profiles from individual accounts.


Accounts can be charted and graphed for reporting
Accounts can be grouped ( commercial accounts, large users)
Usage on the system for a particular time period
Demand on the system at any given time

Load Control by remote valves.


Ability to shut off any customer via MOSAIC or Handheld
Remote Disconnect Via Internal electric relay
Remote shutoff via RSR (Remote Shutoff Relay)
Manage water mains via remote Valves
System security and contamination control

Distribution-Leak Management
Compatible with the Permalog + acoustic technologies used to pinpoint
Utility side leaks

29
REMOTE SHUTOFF VALVE

Available in EOS Mesh or standalone.

Operated via handheld computer.

Compact, IP68 enclosure.

Available in most residential and commercial sizes.

Can be ordered with “Complete” or “Life Support/Trickle” shutoff


options.

30
PermaLog Leak Noise Logger

Fact: A single 5 gpm leak in a main


will waste 2,600,000 gallons of
water per year!

PermaLogs detect and locate


leaks throughout the distribution
system

Read over EOS mesh network

Checks the entire distribution


system for leaks daily without
leaving the office!

31
Small Solution

Small Water Meter & Valve


Radio Frequence Transmiter
- Collect pulses
generated by
meters;

Small Motion Sensor + - Collects information of


MBUS Protocol;
- Data Storage;
WMNET RF
- RF Transmission

32 19
19
Individual Measurement System
SHS Series CT
KEY SPECIFICATIONS
Window Size: .4 Inches
Current Ranges : 5A CT: 0.05 - 7A AC
15A CT: 0.15-20A AC
Output Signal: 333 mV AC at rated current
Accuracy +/- 0.5% at 0.5% to 140% of rated current

ELECTRICAL
Output Signal: 333mV
Accuracy: +/- 1% at 0.5% to 140% of rated current
Phase Shift: +/- 0.5° at rated current
Frequency Range: 10 Hz to 10 KHz +
OTHER FEATURES
Weight: 4.8 oz Radio Frequence Transmiter
Dielectric Strength: 5000V around the case
600V rated leads
Storage Temperature: 220 °F
Case Protection: Plastic ABS/PVS or Epoxy
encapsulated housing
EOS RF
Safety: ETL Recognized per UL506

33 17
17
Central Database
Summary:
From a central database you get the graphic charts and customized graphics to run
and monitor the systems. You also have built in interface to smart phones.

Key notes:
Although systems like this are common, we have the ability to sell the customer
the software to run on their network and reside within their intranet. Having the
web-hosting is also an option.

34 20
20

Potrebbero piacerti anche