Sei sulla pagina 1di 23

Rate and register APM drives

Standard Single & Low Harmonic Drive


Presented by: Leo Fuchs

Confidential Property of Schneider Electric


To get the password for SoMove

Partner Country
Must be qualified as
APM partner • Train & Qualify Partner
(certificates)
Register on SE as
Panel Builder by partner • Support the partner
(link to PRM portal) • Check BfO account for PB

Send the password


request direct form
SoMove BfO - UIMS Number of
registered partner

SEPD

Create SoMove
Password
Confidential Property of Schneider Electric | Page 2
Altivar Process Modular
How to register a Partner?
APM Registration Form
 Link on SE-BOX: https://schneider-electric.box.com/v/APM-registration-form
 Red marked input fields are mandatory:

Confidential Property of Schneider Electric | Page 3


Altivar Process Modular
How to register a Partner?
APM Registration Form
 Enter the details for PRM and SoMove activation:

Confidential Property of Schneider Electric | Page 4


Altivar Process Modular
How to register a Partner?
Windows Login Name

Use the Key combination [Windows] + [R] and


type "CMD" into the window.

Type the command

"set username"

Confidential Property of Schneider Electric | Page 5


Altivar Process Modular
How to register a Partner?
APM Registration Form

 Enter details of APM representative and


send it back to APM-registration@schneider-electric.com

Confidential Property of Schneider Electric | Page 6


Altivar Process Modular
SoMove Partner Tab activation
Registration Email:

Partner: Schneider Employee:

Confidential Property of Schneider Electric | Page 7


Altivar Process Modular
PRM access for Schneider Employees

Here is how PAEs/Services/PMs can register :

Create Email Address with APM & SESA No. eg. APM_SESA94709@...
Use this Email Address to make a self-registration using https://www.schneider-electric.com/en/partners/  
Use Company with APM & Country eg. APM_Austria
send it back to APM-registration@schneider-electric.com

Confidential Property of Schneider Electric | Page 8


SoMove – APM Drive rating
What you need to be able to rate a APM Drive with SoMove
 Successful training for APM – offer

 You must be registered on partner portal as Panel Builder


 How to register you will find in the Register to SE-Partner Page.ppt

 Download SoMove (> V2.7.5) from SE Page (click here)


 and DTM ATV 9xx DTM (>2.2.1) & ATV 6xx DTM (>2.5.1) (Click here)

 Send the request for the APM-Partner Password


 Follow the instruction on the registration on next page

 Cable to connect with the APM drive


 USB – Modbus cable TCSMCNAM3M002P (click here) for Modbus serial or
 Standard Ethernet-Netzwerkkabel, RJ45 for Modbus IPV6

 Look
 in the integration manual – Standard / LH-Regen / Braking Unit

Confidential Property of Schneider Electric | Page 9


SoMove – APM Drive rating
What you need to be able to rate a APM Drive with SoMove

 To rate the standard APM drive see the tutorial


(click here)

 To rate the Low Harmonic APM drive see the tutorial


(click here)

 To rate the Braking Unit see the tutorial


(coming soon)

Confidential Property of Schneider Electric | Page 10


Error during Rating
Now serial number is shown

Internal Error 30/29  Not all Power Modules are supplied with 24 V

Confidential Property of Schneider Electric | Page 11


Error during Rating
Now serial number is shown

No Error on the HMI Power Supply is on the


connected on the control
No serial Number on the Modules
electronic and not on X4

Confidential Property of Schneider Electric | Page 12


Problems during Rating and Registration
Power supply 24V and Digi Link Cable

Digi Link
X21-X26

external 24 V
connection X4
on power module

Confidential Property of Schneider Electric | Page 13


Connection
APM: Altivar Process Modules – needed for Rating and Registration
HMI

Grid Voltage X1

DC Voltage X2

Motor Voltage X3

24 V Connection X5

Power board

Digi Link
Control
X21-X26
Electronics
Fan Command X6

external 24 V
connection X4
on power module
Confidential Property of Schneider Electric 14
Confidential Property of Schneider Electric | Page 15
Offer Overview – Control Unit (APM)
APM: Altivar Process Modules – Design Concept – ATV6B0
Motor Voltage X3
DC Voltage X2
Grid Voltage X1
24 V Connection HMI

Power board Control


Electronics

Modul Link
Board
Fan Command X6
Digi Link
X21-X26

Confidential Property of Schneider Electric 16


Problems during Rating and Registration
Power supply 24V, 230V, Module Link and Digi Link Cable

24 V Connection

Modul Link
Connection for
SoMove

Modul - Link

external 24 V

Digi - Link

Confidential Property of Schneider Electric | Page 17


Problems during Rating and Registration
Power supply 24V, 230V, Module Link and Digi Link Cable

Modul - Link

external 24 V

external 230 V

Confidential Property of Schneider Electric | Page 18


What you have to do after power unit change
For Standard power unit

Change the power unit.


• No additional rating
• No additional registration

Confidential Property of Schneider Electric | Page 19


Change Altivar Process Power Unit (APM)

Change the power unit, no additional rating or registration


necessary

Confidential Property of Schneider Electric | Page 20


Change Altivar Process LH Modules (APM)
APM: Altivar Process Modules – Design Concept – ATVxB0

Need Can Open Address Change the Inverter unit,


Change with HMI no additional rating or
registration necessary

Active Front End

Inverter
Confidential Property of Schneider Electric 21
After change the AFE Module of on APM LH-Regen-Drive

Confidential Property of Schneider Electric | Page 22


Question?

Confidential Property of Schneider Electric | Page 23

Potrebbero piacerti anche