Product Inroduction
RTN – Radio Transmission Node
www.huawei.com
The OptiX RTN 900 products are available in two types: OptiX RTN 910 and OptiX RTN 950. The
IDU of the OptiX RTN 910 is 1U high and supports one or two IF boards. The IDU of the OptiX
RTN 950 is 2U high and supports one to six IF boards. The users can choose an appropriate type
based on the actual requirements.
The OptiX RTN 900 provides several types of service interfaces, facilitates installation and flexible
configuration. It can provide a solution that is integrated with the TDM microwave, Hybrid
microwave, and Packet microwave based on the network requirements. The solution can evolve
based on the service changes that occur due to radio mobile network evolution. Thus, this solution
can meet the transmission requirements not only 2G and 3G networks, but also future LTE and 4G
networks.
RTN 900 V1R1 support pure packet microwave, and RTN 900 V1R2 support TDM microwave and
Hybrid microwave.
2. Equipment Overview
– 2.1 Equipment Components
• IDU
• ODU
• Antenna
• Intermediate Frequency (IF) Cable
• Hybrid coupler
– 2.2 Equipment Characteristics
IDU 950
N-Type connector ODU
IF Cable
IF Jumper
IDU 950
IF Cable with N-Type Connector in both end IF Jumper with TNC connector and N-Type connector
Paired slots
for housing the service
interface boards or IF boards
•All the boards except the power supply board support hot swapping
Paired slots
Power(1+1)
The CST provides the time division cross-connection, system control and communication, and
clock processing functions. In addition, the CST provides the auxiliary interfaces and management
interfaces.
Grooms TDM service signals between boards. Supports full time division cross-connections
at the VC-12, VC-3, or VC-4 level.
Provides one Ethernet NM interface/NM serial interface .
Provides one NE cascade interface.
Support one external clock interface/ wayside E1 interface.
Note :
The external clock interface and wayside E1 interface are combined into one interface. One interface, however, can
implement only one of the three functions: external clock interface, wayside E1 service, and transparent transmission
of the overhead byte.
Note :
The CST boards can be inserted only in slots 7 and 8 in the IDU 950 chassis and form
a 1+1 protection group.
The CST board cannot be installed in the IDU 910 chassis.
• The CSH provides the 10 Gbit/s packet switching, full time division cross-connection,
system control and communication, and clock processing functions. In addition, the
CSH provides auxiliary interfaces and management interfaces.
–Supports full time division cross-connections at the VC-12, VC-3, or VC-4 level.
–Support Packet Switch, Provides the 10 Gbit/s packet switching capability.
–Provides one Ethernet NM interface/ NM serial interface.
–Provides one NE cascade interface.
–Provides one input and one output of the external clock. / Bypass E1 service
interface.
Note :
The external clock interface and wayside E1 interface are combined into one interface. One interface, however, can
implement only one of the three functions: external clock interface, wayside E1 service, and transparent transmission
of the overhead byte.
The CSH boards can be inserted only in slots 7 and 8 in the IDU 950 chassis and form
a 1+1 protection group.
The CSH board cannot be installed in the IDU 910 chassis.
The IF1 is a medium-capacity SDH IF board . The IF1 board has the following
functions
IF processing functions:
Maps SDH and PDH service signals.
Codes and decodes microwave frame signals.
Modulates and demodulates microwave frame signals and ODU control signals
Combines and splits service signals, ODU control signals, and -48 V power
supplies.
Support ATPC ( Automatic Transmit Power Control ) function.
Protection Processing functions:
Support 1+1 HSB/FD/SD protection.
Support 1+1 FD/SD hitless switching.
Support N+1 protection.
IDU 910:
The IF1 board can be
inserted in slot 3 or slot 4.
IDU 910
IDU 950:
The IF1 board can be inserted in any of
slots 1 to 6.
To configure a 1+1 FD/SD protection
group, the IFE2 boards must be inserted in
paired slots.
The paired slots supported by the IDU 950
are as follows: (slot 1, slot 2), (slot 3, slot IDU 950
5), and (slot 4, slot 6).
The IFU2 is a general IF board, which can support the Hybrid microwave transmission and Packet
microwave transmission at the same time. In this version, the IFU2 supports only the Hybrid
microwave transmission.
Supports the Hybrid microwave frames, and supports the pure transmission of E1 or Ethernet
signals.
Supports the adaptive modulation (AM) technology.
Provides a maximum of 56 MHz signal bandwidth and supports the highest modulation mode of
256QAM.
Maps service signals into microwave frame signals.
Codes and decodes microwave frame signals.
Modulates and demodulates microwave frame signals and ODU control signals.
Combines and splits service signals, ODU control signals, and -48 V power supplies.
IDU 950:
The IFU2 board can be inserted in any of
slots 1 to 6.
To configure a 1+1 FD/SD protection
group, the IFE2 boards must be inserted in
paired slots.
The paired slots supported by the IDU 950
are as follows: (slot 1, slot 2), (slot 3, slot IDU 950
5), and (slot 4, slot 6).
The IFX2 is a general IF board, which can support the XPIC (cross polarization interference cancellation)
function of the Hybrid microwave and SDH microwave..
Supports the XPIC function, provides the XPIC input and output interfaces, and supports the manual
configuration of the XPIC function.
Supports the Hybrid microwave frames and supports the pure and hybrid transmission for E1 or
Ethernet signals.
Supports the adaptive modulation (AM) technology.
Provides the maximum signal bandwidth of 56 MHz and supports the highest modulation mode of
256QAM.
Maps service signals into microwave frame signals.
Codes and decodes microwave frame signals.
Modulates and demodulates microwave frame signals and ODU control signals.
Combines and splits service signals, ODU control signals, and -48 V power supplies.
IDU 910:
The IFX2 board can be
inserted in slot 3 or slot 4.
IDU 910
IDU 950:
The IFX2 board can be inserted in any of
slots 1 to 6.
To configure a 1+1 FD/SD protection
group, the IFE2 boards must be inserted in
paired slots.
The paired slots supported by the IDU 950
are as follows: (slot 1, slot 2), (slot 3, slot IDU 950
5), and (slot 4, slot 6).
The SL1D is an SDH dual-port STM-1 board. The SL1D transmits and
receives 2xSTM-1 optical signals.
Supports the automatic laser shutdown (ALS) function.
Supports SNCP and LMSP.
Supports the inloop and outloop over optical interfaces.
Supports the outloop on VC-4 paths.
Supports the warm reset and cold reset on the board.
Supports the query of the board manufacturing information.
The SP3S is a 16xE1 75-ohm/120-ohm tributary board. The SP3D is a 32xE1 75-ohm/120-ohm
tributary board.
The E1 interface impedance of the SP3S/SP3D can be identified by the board feature code of
the bar code. In the bar code, the board feature code is the number next to the board name.
A 120
B 75
NOTE:
In the case of the OptiX RTN 900, only the ports 1-16 and 22-37 of the SP3D interface are used. Ports
1-16 correspond to E1 signals 1-16 and ports 22-37 correspond to E1 signals 17-32.
The AUX is the auxiliary and management interface board of the OptiX RTN 950
V1R2. One NE can house only one AUX.
The AUX provides multiple auxiliary interfaces and management interfaces, including
the one orderwire interface, one synchronous and asynchronous data interface, and one
four-input/two-output external alarm interface.
Provides one orderwire interface.
Provides one 64 kbit/s synchronous transparent data interface.
Supports one 19.2 kbit/s asynchronous transparent data interface.
Supports the input of four channels of external alarms.
Supports the output of two channels of external alarms.
Supports hot swapping.
Supports the detection of the board power supply.
One PIU board whose functional version is One PIU board whose functional version is TND1 accesses
TNC1 accesses two –48 V DC (or -60 V
one –48 V DC (or –60 V DC) power supply for the
DC) power supplies for the equipment. The
two power supplies function as a hot equipment. The PIU boards that have the functional version
backup for each other. of TND1 are fixedly inserted in slot 9 and slot 10. The two
PIU boards function as a hot backup for each other.
IDU 910:
The FAN board whose
functional version is TNC1 is
fixedly inserted in slot 6.
Accesses one +12 V power Indicator
supply for driving three fans,
each of which consumes 6 W
power.
IDU 950:
ESD Wrist Strap Jack
The FAN board whose
functional version is TND1 is
fixedly inserted in slot 11.
Accesses two +12 V power
supplies for driving six fans,
each of which consumes 6 W
power.