Sei sulla pagina 1di 15

IOT Based Mobile Controlled

Kyphosis Detection And Recovery


Measurement Technique Of
Human Spine
Presented By:

Anwesha Chowdhury
Sandip Kumar Karmakar
Dhiren Lalwani
Bikash Kumar Singh
Avik Bandyopadhyay
Kriti Ghorui
PROBLEM STATEMENT
 ORC (Ortho Spinal Round Back Curvature) Kyphosis is an
excessive outward spinal curve in the upper back.

 Kyphotic angle ranges between 20 to 45 degrees.

 But when the curvature is greater than threshold range, then


it’s called Kyphosis.

 Doctors usually prescribe PCPRB(Posture-Correction-Pain-


Relieving-Brace).

 Kyphosis patient can’t know how much bend of the thoracic


spine is recovered and how long he/she have to wear this belt.
NORMAL SPINE V/S KYPHOTIC
SPINE
PROPOSED WORK
 Introduce an IOT based mobile controlled
Kyphosis-Recovery-Measurement-Outercover-
Strip.
Measuring the bend of the upper thoracic spine.
Measuring the bend of the lower thoracic spine.
Mobile-Controlled-Data-Transferring-Box
 Provide analytical damage report
 Provide analytical and graphical report of the
recovery from our proposed Android Application.
SOLUTION TO KYPHOSIS
HOW RESISTANCE INCREASES WITH
THE INCREASE IN THE BEND ANGLE

NOTE: The resistance values mentioned here are specific to


the Flex Sensor which we are using and they are not
universal.
FLOW CHART OF OUR PROPOSED WORK
BLOCK DIAGRAM
CIRCUIT DIAGRAM
FLEX SENSOR CIRCUIT CONSISTING
OF A VOLTAGE DIVIDER AND AN
OPERATIONAL AMPLIFIER
COMPONENTS USED

Node Mcu Flex Arduino


ESP8266 Sensor Uno

Breadboar
Jumper wire
d
ADVANTAGES OF OUR
PROPOSED SYSTEM
 Low cost
 Low power
 Fully Automated
 Fast Response
 Reliable
 Pollution Free
REFERENCES
 Langford G. B. 1996. Flexible potentiometer. US 5 583 476. 

 Joshy A., S. Senthil kumar. 2012. A sensor network system for


identifying landslide detection, monitoring and predicting of
forewarning time. Int. J. Electr. Eng. Embedded Syst. 43-48.  

 Sye Loong Keoh, Sandeep S. Kumar, Hannes Tschofenig, Securing the


Internet of Things/; A Standardization Perspective, June 2014

 .Chabbila P. S. 2016. To detect status of door using flex sensor for


home application. EThesis@NIT Rourkela.
URL:http://ethesis.nitrkl.ac.in.
CONCLUSION
 The significance of technological advancement is at peak
in today’s modern world and we have tried to make a
crude effort at contributing to it by modifying the PCPRB.

 Our project aims at simplifying the process of


understanding the medical recovery of a patient.

 The KRMA is not only helpful for a patient to track the


recovery of Kyphosis but also helpful to understand how
long they have to continue their diagnosis using the belt.
Thank You