Detailed description of electronics menu
bbbb 2
Detailed description of electronics menu
bbbb 3
Detailed description of electronics menu
LAMP
err
0 no error
1 Underrange error (signal)
2 Overrange error (signal)
3 Underrange reference counter
4 Overrange reference counter
bbbb 4
Detailed description of electronics menu
CUVET
err
0 no error
1 Underrange error (signal)
2 Overrange error (signal)
3 Underrange reference counter
4 Overrange reference counter
bbbb 5
Detailed description of electronics menu
Lamp 505
bbbb 6
Detailed description of electronics menu
cuvet 505
bbbb 7
SR3/SR75
bbbb 8
SR3/SR75
bbbb 9
SR3/SR75
bbbb 10
SR3/SR75
bbbb 11
SR3/SR75
Alternative check-solution
Cobalt 2 Sulfate
Absorbance maximum at 510nm
bbbb 12
Maintenance of syringe mechanisme
bbbb 13
Maintenance of optical mechanism
bbbb 14
Maintenance of optical mechanism
• Lamp adjustment
• Photo-sensor adjustment
• Cuvette-rotor adjustment
• Cleaning the optical filters
• Replace optical filters when
needed
bbbb 15
Reagent needle ball bearing
• When got rusty, replace the bearing
• Bearing gets rusty when it often gets wet, probably caused by bad
adjusted PLL.
bbbb 16
Vacuum pump membranes
• Membranes should be replaced every half year
• There are two types available
– Gray membrane pn: 6002-040
– Red Membrane pn: 3913-049
• Chamber kit should be replaced every two years
• There will almost always be a little liquid in the system, due to the
design of the system (waste gasks)
bbbb 17
2-way valves
• Consumption two-way valve is about 100/year/5000instr
• Consumption three-way valve is about 100/year/5000instr
bbbb 18
Syringe tips
• Regular lifetime of a sample tip should be 4-6 weeks (depending on
the workload)
bbbb 19
Air bubbles in the water system
• Air bubbles are trapped in the tubing system
• Use of fresh tapped de-ionized water contains a lot of dissolved
water
– Use a spare canister of water, so dissolved air can escape from
the water
• Use of system liquid avoids air bubbles sticking to the tubing
bbbb 20
Maintenance kits suggestions for
• ½ Yearly kit
improvement
• Yearly kit
• Food analysis instruments
bbbb 21
SD_error on reaction rotor
• Important not to make scratches
on the rotor when searching for
the slit to fit.
• Important not to touch the
cuvette with the fingers
• In future software it will be
possible to exclude cuvettes from
measurement
bbbb 22
Overfilling the drain positions of the needle
• September 2003 a drain modification has been send out to all XL
instruments (distributors) at that time. The content of the drain was
enlarged
bbbb 23
User items
Problems with TP, Mg, Ca, Glucose
• What are the problems
• Collect as much information as possible
bbbb 24
User items
How to improve low throughput
• make an inventory of test volume per analyte
• Separate 50% left and 50% right
• Separate incompatible tests, left and right
• Avoid a lot of incompatibilities
bbbb 25
User items
Incompatibilities (which are necessary or
not)
• Incompatibilities are depending on the reagents
• The reagent manufacturer should be able to advise
Lactate Test
LDH
L-Lactate + NAD+ ------------------- Pyruvate + NADH + H+
bbbb 26
User items
Incompatibilities (which are necessary or
not)
ALT Test
ALT
L-alanine + α-ketoglutarate ---------------------- L-glutamate + pyruvate
LDH
Pyruvate + NADH + H+ --------------------------- Lactate + NAD+
bbbb 27
User items
Incompatibilities (which are necessary or
not)
TRIG Test
Lipase
Triglicerides --------------------------- Glyserol + Fatty Acids
GDH
Glycerol + NAD+ -------------------- Dihydroxyacetone + NADH + H+
bbbb 28
User items
Selective unload possible?
• NO when bar-code option is switched off
bbbb 29
User items
Printer compatibility problems
• Flexor E and XL use an external printer. When the correct driver is
installed there should be no problem
• Only one complete patient report per page
• When report set-up is used, a non-proportional letter-type should be
use (Courier New, San Serif)
• Pictures factor horizontal 6 and vertical 6
bbbb 30
User items
Printout sequence
• Printer will print in the order of measurement and only completed
patient reports.
– This can be disturbed by a remeasurement
– To print e.g. no 15 before 1-14 is only possible by requesting
manually a print by F1(in evaluate samples)
bbbb 31
User items
Sample and dead volume
• Dead volume on cup 50ul
• Dead volume on tubes with standard rotor 500ul
• Low dead-volume rotor (E) pn: 6002-121 200ul
bbbb 32
User items
Programming applications
• Read insert sheet
• The used wavelength should be mentioned
• Should indicate endpoint, two point or kinetic
• Should give pipetting volumes
– Reduce these volume to min-max cuvette volume
• If test is a long endpoint, maybe it could run as a kinetic test
– This can be tested to run it as kinetic and use the longest reading
possible
bbbb 33
User items
When are the reagents, controls and standards
OK?
bbbb 34
User items
When are the reagents, controls and
standards OK?
• Calibration on 1 standard in duplicate
• Calibration on 1 standard also a reagent blank
• When a drift is seen on the QC graphic
– Recalibrate
– Refresh reagents
bbbb 35
User items
Power schemes of the PC and Monitor
• Vital advises to keep them switched on
– Screen can be switched off by its main-switch
bbbb 36
User items
ISE module disadvantages and
incompatibilities
• Minimum of samples / day = 25
• Ratio human sample : calibrators/controls
20 : 1
• Model 9130 VS is only compatible with Flexor / Selectra
• Q1 2005 Dry ISE will be introduced
bbbb 37