Sei sulla pagina 1di 17

SOLUTION FOR RESIDENTIAL

Residential Category

High End Residential Mid-End Residential


Solution For High-End Residential

Kitchen

Closet
Living Room

Bedroom
Bathroom
Mostly Problem Occured

Oil Fumes Stick On The Household Molds


Wall

Peeling Walls Smelly Closets


Daikin Home Central Air
Conditioning Solution

IS THERE ANY SOLUTION


FOR THOSE PROBLEMS?
VRV HCAC Line Up
Living and Bed Room Application

3DDirect airflow
Airflow to the
ensures bed
uniform Gentle circulationdoesn’t
Air distribution of airflow
distribution throughout largeofspaces
reach all corner room

Presence Sensor

Floor Sensor
Moisture Control Intelligent 3D Airflow

Airflow can be adjust


through remote control and
Intelligent 3D Airflow the flap can move up to 450
up and down.
Issue in The Kitchen and Closet

Oil fumes trapped and stick


on the walls

Humid and heat released causes


coating walls adhesiveness
decrease, consequently it easy
to peel.

High moisture and wet clothes


make an odor for room.

Is there any solution to solve the problem?


Kitchen and closet needs special cooling to distribute
fresh air at the same time. For kitchen, special filter
becomes important to absorb oil fumes from the
combustion process.
Indoor Unit for Kitchen and Closet Use
Create a comfortable environment by
delivering gentle airflow and control
moisture level. And also rapid removal
heat by filtering oil fumes for kitchen  The difference for kitchen use:
use.
Smart fin with wider spacing and
smooth surface to prevent
grease holding.
 2,2 kW effectively correspond to cooling and
dehumidify kitchen and closet area between
8 – 10 m2.
VRV Indoor Unit for Kitchen Specification
and Closet Use Capacity ( k
Cooling 2.20
W)
Capacity ( k
Heating 2.20
 Air outlet closed W)
seamlessly to prevent Dimension Indoor unit 540×555×230
dust and mosquitoes. D×W×H 640×625×60 ( Insi
Panel
(mm) de the ceiling 45)
Issue In The Bathroom
Generally, bathroom
always in wet condition
that will lead molds to
grow more easy.

Dump problems, molds,


and bad air circulation will
make unpleasant odors.

Is there any solution to solve the problem?


Bathroom has higher moisture level than the other rooms
in the house. It is necessary for the air system that able to
reduce humidity automatically, and also has exhaust
function to remove odor in the bathroom.
Indoor Unit for Bathroom Use
 Overcoming high humidity problem and
create fresh environment in the
bathroom.
 Ventilation function can be used to
remove moisture and odours.
Specification
Capacity ( k
Cooling 1.95
W)
Capacity ( k
VRV Indoor Unit for Heating 3.20
W)
Bathroom Use Dimension Indoor Unit 540×555×230
D×W×H Exhaust Fan 370×245×200
(mm) //////////////////////////////////////////////////
Panel 640×625×60

Exhaust

90°Angle 120°Angle Ceiling


Return Supply
Flap, direct Flap, wider air
Air Air
to floor flow range
Special Airconditioning Process

Dehumidification/Dry Mode
After used, the room with dump
Discharge
circumtance led to high humidity. Then,
Intake indoor unit automatically run a dry mode,
and the moisture will be brought with
return air to exhaust.
Dehumidification capacity: 1.4L / H
High Humidity Area

Cooling Drying Mode


The use of reheat dehumidification,
indoor environment 28 ℃, relative
Exhaust humidity 60%, 6kg clothing 2.5h to
Discharge Intake Discharge Intake complete drying.
Heating Drying Mode
The use of heating drying clothes,
the same 6kg clothing 2.5h complete
<Cooling Drying Mode> <Heating Drying Mode>
drying.
Moisture Control
【 Comfort Cooling Mode 】
•Maintain indoor temperature
•Controlling the moisture level
•To bring better comfort
environment

【 Sweet Dream Mode 】


•Temperatur control between 26℃±2℃
•Indoor moisture level between 45%-60%
•Provide user restful sleep

【 Auto Moisture Control 】


•Intelligent Moisture Control
•Automatically turn ON when the moisture
level is higher than 75%,
•Automatically turn OFF when the moisture
level is lower than 60%
Specification

Outdoor Unit
Capacity
4 5 6 8 9 10 12
(HP)
COP 3.70 3.46 3.31 3.73 3.42 3.88 3.68

Model Name RPZQ4AAV RPZQ5AAV RPZQ6AAV RPZQ8AAY RPZQ9AAY RPZQ10AAY RPZQ12AAY

Appearance
Moisture Control Indoor Unit
Capacity Range (HP)
Model
0.8 1 1.25 1.6 2 2.5

FPEKQ-AV1
(Kitchen Use)

Moisture
Control FPEBQ-AV1
Ceiling (Bathroom Use)

Cassette

FPECQ-AV1
(Closet Use)

FPRSQ-APV1
Ceiling (Moisture Control
Mounted Duct Intelligent 3D
Airflow)
Ceiling Duct Indoor Unit

Capacity Range (HP)


Model
0.8 1 1.25 1.6 2 2.5

FPDSQ-APV1
Ceiling
(Intelligent 3D
Mounted Duct
Airflow)

Medium Static
Ceiling FPSQ-CV1
Mounted Duct

Compact
Ceiling FPDQ-APV1
Mounted Duct

Potrebbero piacerti anche