QUALIStar

Product
presentation

The Qualistar+, the latest in


Chauvin Arnoux's range of
electrical network analysers
Market

Current state of the power measurement market


Application markets
2 categories of users work on the installations

Continuity of Energy
service efficiency

• Corrective operations
• Preventive operations  Rising energy prices
• Periodic verifications  Growing environmental concerns
Continuous on-site maintenance

 An engineer is called upon to work on an installation


in all types of situations:
 Emergency intervention: fault or troubleshooting
 Preventive or predictive

 Area of use
 On-site intervention

 Types of interventions
 Immediate measurements
 Monitoring
Energy Efficiency = Savings
 People involved
 Technical teams on the sites
Teams in the front line in the event of a fault.
 External service providers
Intervene on request.
Often include certification organizations.
 Areas of use
 Identifying potential savings on sites
involving multiple types of consumption
 Measuring energy efficiency
 Ensuring that energy-saving initiatives are maintained over the long term
 Continuously measuring the effectiveness of the energy-saving initiatives
 Identifying power reserves in the energy distribution system
Energy efficiency
4 steps for an energy survey

  Audits: Complete diagnosis of the site

  Analyse: Assessment of potential savings

 Implementation:
 Complete and renovate the existing
system
  Install a new solution
 Follow-up:
 Scheduled campaigns
 Constant measurements
Main qualimetric measurements

Recordings Power
diagnosis

Troubleshooting
Chauvin Arnoux

Acknowledged expertise on the portable


power measurement market

115 years of experience


85 years of wattmeters
20 years of handheld wattmeters
Since 2001: the Qualistar

And today…
C.A 8335
What is a QualiSTAR?

 Power measurement
instruments offering all the
measurements required to
understand the operation of
your electrical network.

 Portable three-phase
wattmeters designed for
industrial environments and
suitable for use on the whole
low-voltage installation.

Plus years of experience…


The C.A 8335

A user-friendly diagnostic tool


 Large, easy-to-read colour
screen
 ¼ VGA
 diagonal 148 mm

 Lightweight, rugged casing for


use in the field
 Less than 2 kg
 Proven casing

 Keys for direct access


 Intuitive use
 Simplicity

 Operation on batteries
 More than 30 hours
Specially-designed ergonomics
A tool for working
 The QualiSTAR power measurement
instruments are particularly easy to handle
 Side strap making it easy to hold
 Stand to work in comfort
 Carrying bag for "hands-free" use
Instrument connections

 4 current inputs  1 USB interface


 for measuring all the channels  for communication
of a three-phase installation. between the instrument
 5 voltage inputs and a PC.
 for measuring all the voltages  1 mains adapter input
on a three-phase installation  for battery recharging
 mains power supply
Voltage and current
measurements

 Range:
 voltage up to 1,200 V RMS AC+DC
 current up to 6,500 A RMS AC+DC

Half-period RMS values as per IEC 61000-4-30

 Electrical safety
 IEC 61010 1,000 V CAT III – 600 V CAT IV
Customization of the inputs

 The instrument is delivered with a set of inserts and rings


supplied in 11 colours
 Customization of the measurement inputs and
leads/sensors
 Adaptation to all countries
Simple use

 Use of intuitive icons

 Online help at all times


Explanations of all the parameters
displayed on screen are always
available
 Multilingual
The online help, menus and information
messages are available in more than
20 languages
Simplicity: direct access

Transients Harmonics Wave forms

Alarms Trend Power values


Explicit screen
Time/date-stamp
Mode and battery status
used

Available curves
and measurements

Cursor data
Curve display filter

Tab for direct


access to other
measurementss
Wave forms
 Display of the wave forms of the voltages
and currents: qualitative view of signal
distortion for voltage or current, or per
phase.
 Comparison of amplitudes and display of
phase shifts between the fundamentals of
each phase, as well as between the
currents and voltages.
 Text summary of the min, max and
average parameters measured

 Verification of correct phase connection by


vectorial display
 Calculation of the shift angles between
phases and of the absolute value
 Unbalance measurement
Power / Energy modes

 Display of the power values and


associated factors (power factor,
displacement power factor and
tangent)

 Possibility of integrating this power


value for energy metering.

 Pictograms distinguishing between


energy consumed and energy
produced.
Harmonics mode
 Bargraph display of the harmonic distortion
levels of the voltages, currents and powers,
order by order up to the 50th order.

 Display of the THD in %, the RMS value and


the phase shift of each harmonic.

 The bars representing the harmonics are


signed. As the QualistarPlus is the receiver,
the positive harmonics are received and the
negative harmonics are transmitted
(pictogram).

 The expert mode allows distinction between


the harmonics inducing a negative, null
(addition in neutral) or positive sequence. It is
then possible to analyse the influence of the
harmonics on heating of the neutral or on
rotating machinery.
Simultaneous monitoring

Stream recording of the parameters


over very long periods(overvoltages,
drops and interruptions, etc.).

Triggering and capture of events


Monitoring of parameters which do not comply with
predefined characteristics.

Capture of very brief voltage and


current events
Recording mode

 Curve or bargraph display of the various


parameters recorded, as well as the min
and max values as a function of time.
 Verification of mains voltage stability.
 Monitoring of all the parameters over
time.
 Calculation of the energies consumed
and output
 Capacity (example): all the parameters
at one-second intervals for nearly one
month
Alarms mode

 Listing of the 10,000 alarms


recorded according to the
thresholds programmed in the
configuration
 Recording of power cuts from one
half-period to several hours
 Determination of energy
consumption overruns
 Detection of voltage variations on
the network
Transient mode

 Display of wave forms captured


after a transient.
 At 50 Hz, capture of transients
lasting less than 80 µs.
 Display of rapid variations
(interruptions, etc.)

C.A 8335: 210 screens


Inrush current mode
 Analysis of motor start-up: recording
of the curve over a period of more
than one minute at 50 Hz, with start-
up duration and peak values
 Display of the curve in envelope mode
(PEAK)
 Display of each half-period in RMS
mode
 Possibility of multiple zooms until
each period is displayed
Configuration

 A simple set-up screen, without


nested sub-menus, allows you to
set your instrument's
parameters as required:
 Adjustment of the screen
 Choice of colours for the traces
 Calculation mode for certain
parameters
 Type of electrical installation
 …
Screenshots

 A special key allows users to


save specific screens on the
analyser so that they can recall
and view them later on.

 The screenshot comprises a


.BMP file of the image and the
data for the curves.

C.A 8332B: 8 screens


C.A 8334B: 12 screens
C.A 8335: 50 screens
State at delivery

 The instrument is
delivered in a
carrying bag with:
 3 m measurement leads,
 Crocodile clips,
 A PC connection cable,
 Software for recovering
the data on a PC,
 The operating manuals
Current sensors

Choice of current sensors


according to user requirements

 Different types of current sensors


adapted to the measurement
ranges.

 Automatic recognition of the


sensors
Analysis of the results

 DataView: the software for the


Qualistar

 Recovery and back-up of the


data recorded
 Graphic display of curves and
trends
 Automatic production of
measurement campaign
reports
 Preparation of a measurement
campaign
CA's Qualimetry Offer

C.A 8352

C.A 8340

C.A 8335
C.A 8334B

C.A 8332B

C.A 8230
ns
tio
unc
F
Summary…

 Simple

 Compact and portable

 Large storage capacity

 Versatile

 4U / 4I

 Inrush mode

 1,200 V

 Safety