Sei sulla pagina 1di 7

NBC STANDARDS:

HOTEL

FIXTURES PUBLIC ROOMS NON-RESIDENTIAL


STUFF
TOILET SUITE INDIVIDUAL GUEST
COMPRISING 1 WC , ROOM WITH _________
WASHBASIN WITH ATTACHED TOILET
SHOWER AND FOR MALE AND
BATHTUB FEMALE
GUEST ROOMS WITH COMMON FACILITIES
PUBLIC ROOMS
FACILITIES MALE FEMALE
WATER-CLOSETS 1 /100 PERSON UPTO 2/100 PERSONS OR
400 UPTO 200
OVER 400 ADD 1/250 OVER 200 ADD 1/100
OR PART THEREOF OR PART THEREOF
ABLUTION TAP ONE IN EACH WATER ONE IN EACH WATER
CLOSET CLOSET
URINALS 1/50 PERSON OR PART -
THEREOF
1 WATER TAP WITH DRAINING ARRANGEMENTS SHALL BE PROVIDED FOR
EVERY 50 PERSONS OR PART THEREOF IN VICINITY OF WATER CLOSETS AND
URINALS
WASHBASINS 1 PER WC/URINAL 1 PER WC
BATH(SHOWER) 1 PER 10 PERSON OR PART THEREOF
CLEANER’S SINK 130 ROOMS , MINIMUM 1 PER FLOOR
KITCHEN SINK 1 PER KITCHEN
GUEST ROOMS WITH COMMON FACILITIES
NON-RESIDENTIAL STUFF
FACILITIES MALE FEMALE
WATER-CLOSETS 1 FOR UPTO 15 1 FOR UPTO 12
2 FOR 16-35 2 FOR13-25
3 FOR 36-65 3 FOR 26-40
4 FOR 66-100 4 FOR 41-57
5 FOR 58-77
6 FOR 78-100
ABLUTION TAP ONE IN EACH WATER ONE IN EACH WATER
CLOSET CLOSET
URINALS NIL UPTO 6 -
1 FOR 7-20
3 FOR 46-70
4 FOR 71-100
1 WATER TAP WITH DRAINING ARRANGEMENTS SHALL BE PROVIDED FOR
EVERY 50 PERSONS OR PART THEREOF IN VICINITY OF WATER CLOSETS AND
URINALS
FACILITIES MALE FEMALE
WASHBASINS 1 FOR UPTO 15 1 FOR UPTO 12
2 FOR 16-35 2 FOR 13-25
3 FOR 36-65 3 FOR 26-40
4 FOR 66-100 4 FOR 41-57
BATH(SHOWER) -----------------------------------------------
CLEANER’S SINK 1/30 ROOMS , MINIMUM 1 PER
FLOOR
KITCHEN SINK 1 PER KITCHEN

NOTE :-
-- SOME WC MAY BE EUROPEAN STYLE IF DESIRED
--MALE POPULATION MAY BE OBSERVED AS 2/3RD AND FEMALE
POPULATION AS 1/3RD
--PROVISION FOR ADDITIONAL AND SPECIAL FITTINS WHERE
REQUIRED SHALL BE MADE.
OFFICE BUILDING

FIXTURES PUBLIC TOILETS


 Unit could be common for
1. Executive Male/Female or separate
rooms and depending on the number
conference of user of each facility.

halls in office
STAFF TOILET
buildings.
• For individual officer rooms.
(Toilets
comprising one
WC, one
washbasin)
OFFICE BUILDING
PUBLIC TOILETS /
FIXTURES STAFF TOILETS
2.Main office MALE
FEMALE
toilets for staff
and visitors. 1 per 25 1 per 15
1. WC ----1 in each water –
closet----
2. Ablution tap 1 per 25 1 per 25
3. Washbasins 1 per 100 1 per
4. Drinking water 100
-------------1 per floor-------------
fountain
5. Cleaner’s sink
PUBLIC TOILETS
6. Urinals Nil up to 6
1 for 7 – 20
2 for 21 – 45
3 for 46 – 70
4 for 71 – 100
Add @3% for 101 – 200
Add @2.5% for over 200
STAFF TOILETS
Nil up to 6

Potrebbero piacerti anche