General Electric

Micro Processor

Locos
Barometric Pressure
Sensor

Ambient Temperature
Sensor
Red Modules
(Current sensing through shunts)
(Provided in Back Panel)

AGAM Aux. Gen. Armature module

AGFM Aux. Gen. Field Module

BCAM Battery Charging Current Module

EXAM Exciter Gen. Armature Module

EXFM Exciter Gen. Field Module

TMFM Traction Motor Field Module


FRONT PANEL
BACK PANEL
Bright star
Front Panel GE Microprocessor Controlled Locos
Microprocessor
Relays

CPF
CPS

DID

Breakers
Front Panel GE Microprocessor Controlled Locos

Relays
Main Control Panel

CPF

Power Contactors
DID

Breakers
VCD Bypass Toggle Switch – Provided in control compartment
Cut in Position – Normal working
Cut out / Bypass position – Isolates VCD in Trail Loco and unmanned Loco
CKC1, CKC2 & CKC3
MCOS TM isolation Switches.
More than one TM can be isolated
TM Isolating Toggle Switches
Back Panel GE Microprocessor Controlled Locos

Relays
Field Shunting Resistors Main Control Panel

CPF

Power Contactors
DID

Breakers
Toggle Switches (Control Panel)

LBSS Load Box Selector Switch.


Load Box wkg. / Train wkg.)

LBTS Load Box Toggle Switch


For Self Load Box Test mode

DAS Diagnostic Access Switch.


For clearing Level 2 Faults

SCO Sensor Cut Out Switch


Cuts out Speed Sensor of isolated TMs only (to isolate
faulty Sensor)

LACS Locked Axle Cutout Switch.


Isolates locked axle protection

During Faulty Locked Axle, Toggle switches SCO, LACS to


be operated along with isolating defective TMs
Main Circuit Breaker – COB
For all train line circuit, Master Controller Circuit

Battery Circuit Breaker – CCB


For Battery Charging circuit

Crank Case Exhaust Breaker – CEB


For Switching ON / OFF crankcase exhaust motor

Fuel Pump Breaker 1 – FPB1


For Battery positive to FPM circuit

Fuel Pump Breaker 2 – FPB2


For Battery negative to FPM circuit

Microprocessor Signals Circuit Breaker – BCCB


2 Pole breaker connects +ve & -ve supply to
Microprocessor & associated signals
CPU Fan Circuit Breaker – FNB
For Switching ON / OFF CPU Cooling Fan Breaker

Engine Run Switch Circuit Breaker – ERS


For Supplying the Master Controller Contacts through PCR
relay

Generator Field Circuit Breaker – GFB


For Reverser / Braking coil Circuits

Exciter Field Circuit Breaker – ECB


For Exciter Field Circuit

Local Control Circuit Breaker – LCCB


2 pole breaker supplies +ve & –ve to loco control circuits
Auxiliary Field Circuit Breaker – AFCB
For Auxiliary Generator Field Circuit

Eddy Current Clutch Circuit Breaker – ECCB


2 pole breaker supplies +ve & -ve to ECC coil circuit

Dust Exhaust Blower Motor Circuit Breaker (Engine) – EBB1


For Switching ON/ OFF Blower Motors (Engine)

Dust Exhaust Blower Motor Circuit Breaker (Car body) – EBB2


For Switching ON/ OFF Blower Motors (Car body)

Dome Light Circuit Breaker – DLCB


For Switching ON/ OFF Dome Light
Light Circuit Breakers – LPB1 & LPB2
For Switching ON/ OFF Various lights
Head Light Circuit Breaker – HLPB
For Switching ON/ OFF Head light
Tripping of Breakers

ERS Throttle will not respond

LCCB, ECB, GFB Load meter will not respond

ECCB ECC / Radiator fan will not work


Hot Engine will be experienced

AFCB No AG output.
Battery will discharge

BCCB Display blank


Microprocessor OFF
Contactors

CKC1, CKC2 Cranking Control Contactors


CKC3

GS +ve , GS – ve Cranking Contactors

GFC Generator Field Contactor

S14, S25, S36 Series-parallel power Contactor’s

P1 TO P6 Parallel power Contactor

F1 to F6 Field Shunt Contactor


RELAYS
EXFR - Exciter Field relay
• For isolating Exciter shunt
Field during cranking

AGFR - Auxiliary Generator


Field relay
• For isolating AG shunt
Field during cranking

ABCR
• For supplying to the AV,
BV, CV and DV solenoid
ECR1 and ECR2
• Radiator fan relays like R1
& R2 in other Locos

MVR
• Magnet valve Relay, for
Air Drier

CRL
• Compressor Line Relay

DVR
• For connecting the DV
solenoid to the battery

FPR
• For control of Fuel Pump
Motor
PCR- Power Cut Out relay
• This is equivalent to
the DMR in other Locos
PCR FCR
FCR- Flasher Control
relay
• This gives supply to
Flasher light

RVR – Reverser Relay


Energized if RH is in
Neutral.
Reverser will be thrown
according to RH with
TH in IDLE.
FR/FWR- Field
Weakening relay FR
FR FSR RSR
• This relay will
energize during
1st transition

FSR & RSR


• Sanding relays for
applying sand in
Forward and
reverse direction
Other RELAYS PROVIDED
LAR Locked Axle Relay

WSR Wheel Slip Relay

BLR Bell Ring Relay

CGR / GR2 Ground Relay(Control)

PR1 Auto Flasher Relay

PR2 Auto Flasher Reset Relay


Load meter

Indicates the Average


Current flowing in the
Active TMs

Right side indicates


Motoring Current

Left side indicates


Braking Current
2 Line Display with Alpha Numeric keys
First line Parameters / Faults
Second Line Function Key Options
Ground Detection Module
GDM

GRCO1 & GRCO2