Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Product Presentation
DC UPS System
Krishnendu Chakrabarti
Director- Global Business Development
Users Demand
• Highest Reliability
• Long Life
• Should Boost and Float Charge the battery
• Load should not be interrupted in any condition
• Should not exceed maximum allowable voltage limit at load
terminal.
• Should meet the maximum load demand as and when
required during emergency.
• Should monitor all voltages and currents.
• Should annunciate in case of abnormalities in the system.
•
Out of Focus
• MTBF of the system
• MTTR
• Up time calculation
• Complete monitoring of the system including battery, DCDB
and the rectifiers.
• Efficiency
• Power Factor
• Total current harmonics distortion
• Remote interface
• Foot print
The Emerson Flagship Industrial DC UPS
for Heavy Duty Industries
Emerson FP-40RM:
The Industrial DC UPS from Emerson Network Power to protect:
•Transmission substations motorized switchgears
•Power Generation plants processes
•Highly critical processes and control systems
SCR Control System
Benefits
Very Simple
Architecture and easy
to Design.
Widely accepted
technology for last
more than 50 years
Large number of
Manufacturers due
simple technology.
Limitations
Not much scope to improve MTBF due to large number of connections over a long distance
NO scope to improve MTTR due to high volume components and discreet components.
Limited Up time reliability even with 2 x 100% redundancy.
Very difficult proposition to improve Power factor without large capacitor bank and number
of contactors.
Input current harmonics distortions can be controlled with complex 12, 18, 24 pulse design
Not possible for much improvement of Output AC ripple content.
Impossible to improve dynamic response and DC Voltage over shoot
Switch-Mode Technology
PWM 50-100kHz
Advantage Difficulties
Very high energy density means smallest footprint Very complex design
Very low volume of magnetic components ensures high needs special
dynamic response, high efficiency. machineries for high
High frequency switching make design simple for improved reliability.
power factor and THDI Only high volume
Sophisticated manufacturing process ensures very high production can control
reliability. cost.
What we get
Modular Design & Light Weight
Addition of Rectifier Allows For Easy Expansion (Parallel option for redundancy)
On-site Spare Rectifier Modules & Simple Repair Easy Serviceability
Hot Pluggable Rectifier Modules
DC ripple ≤0.1%, regulation ≤0.5%
Dynamic Response < 200 μs
THD < 5% and Input Power Factor ≥ 0.99
Efficiency ≥ 90% on rated Load
MTBF > 2,50,000 Hours
Smaller in size & less in weight.
Global Certification
Utmost Input Performances
for Project Savings
SMPS modules Impact Benefits
performances
Wide input voltage range ► Battery kept fully charged Compliant with the worst Utility
conditions
Possibility to have more load
Integrated Input Power On upstream transformer:
connected to the supply transformer
Factor Corrector (PFC): ► Input current through supply No need to replace the transformer
From 0.92 to 0.99 transformer is reduced by a larger unit
On upstream losses: Reduction of losses in cables
► Line current is reduced Reduction of cable size (-20% from
► Reduced I²R heating in the resistance of PF0.8 to PF0.99)
generators, transformers and cables Reduction of the upstream transformer
Reduction of upstream switchgear
Integrated Power Factor Corrector
Low rejected THDi ► Reduced disturbances for Upstream generator do not need to
<5% (in nominal the other loads connected nearby be oversized
conditions) ► Avoided interferences reflected to the Reduced stress on neutral cables
Mains (GenSet)
Reduced inrush current: Switchgear of smaller ratings can
<1.5 In for FP-60Z w input transformer be selected to pass the inrush
Hot-Swappable Power Modules
for High Availability of Power
Benefits
Rated Voltage: 24V Rated Voltage: 48V Rated Voltage: 110V Rated Voltage: 220V
Rated Current: 75A Rated Current: 50A Rated Current: 10A Rated Current: 5A
Max output power: 2175W Max output power: 2900W Max output power: 1170W Max output power: 1175W
Efficiency: ≥90% Efficiency: ≥91% Efficiency: ≥91% Efficiency: ≥91%
Input Power factor: 0.99 Input Power factor: 0.99 Input Power factor: 0.99 Input Power factor: 0.98
Three-Phase Modules
ER 11020/T ER 11040/T ER 22010/T ER 22020/T
Height: 132.3mm Height: 132.3mm Height: 176mm Height: 145mm
Width: 85.3mm Width: 85.3mm Width: 88mm Width: 72mm
Weight: ~3.5kg Weight: ~3.5kg Weight: ~6kg Weight: ~3kg
Rated Voltage: 110V Rated Voltage: 110V Rated Voltage: 220V Rated Voltage: 220V
Rated Current: 20A Rated Current: 40A Rated Current: 10A Rated Current: 20A
Max output power: 2860W Max output power: 5800W Max output power: 2860W Max output power: 5800W
Efficiency: ≥91% Efficiency: ≥93% Efficiency: ≥91% Efficiency: ≥93%
Input Power factor: 0.92 Input Power factor: 0.99 Input Power factor: 0.92 Input Power factor: 0.99
Output Performances
for Advanced DC Load Protection
Efficiency Benefits
24V/75A: >88%
Savings on the Air conditioning
48V/50A: >91%
110V/20A: >91%
220V/10A: >91%
110V/40A: >93%
220V/20A: >93%
Output Regulation
Static regulation: +/- 0.5% Fast and efficient output regulation to
Low ripple voltage: <0.5% permanently keep the load safe and
within accepted limits
Improved battery lifetime
EMU10: The FP-40RM Control and Displaying Unit
Features: Benefits
Size 7’’
User-friendly navigation
Touch Pad
Quick access to all the information
Push buttons
Coloured graphical display
3 LEDs: Normal, Warning, Alarm
USB port Quick Access
LEDs
Access to System parameters via 2 level buttons
password (User, Maintenance)
Front page drawing configured according to the
system design*
System drawing
Message area
RUN
EDU (standard):
DC measures module
CAN
485
HF ALARM
EAU01
1 to 6 RUN
NORMAL
EAU (optional):
EMERGENCY
ALARM
AC input measures module
HF
CAN
EGU01
POWER
CAN
EGU (optional):
EMU (standard) RS485
ALARM
Switching inputs
EBU01
RS 485
REMU
REMU (standard):
K7
K6
K3
K5
K1
Minimal Standard Configuration
1 MCB per
module
HF
It Uo
1 to 6 Output measures:
230 VAC 1ph •Output current
•Output voltage
EDU01
or
RUN
HF
CAN
485
ALARM
EDU
400 VAC 3ph
EMU Colored
TouchPad 7’’
Pre-Configured Options
Output
Input Dropping Distribution:
protection: Diodes: MCB/ MCCB/
MCB 10kA HF
3 contactors Switch
MCCB 36kA 7 steps It Uo
Uin Iin
1 to 6
Ub
EAU01
Ib RUN
EDU01
RUN
NORMAL
EMERGENCY
EAU
EAU
HF
CAN
485
ALARM
EDU
ALARM
Low voltage
Disconnect
Input measures: contactor
Line current(s)
Ph-N voltage(s)
Battery
Frequency Protection
MCB 10kA EGU01
EBU01
θ
POWER
CAN
EGU
EGU
POWER
EBU RS485
ALARM
EBU
COM
ALARM
RUN
Individual
Battery room
feeder
temperature
Battery Earth fault
Monitoring detection
Lead Acid/ Ni-Cd
Up to 216 cells/
Remote modules
Communication:
Modbus
IEC 61850
AC load Back-up
HF
It Uo
AC Mains
input DC output
1 to 6
Ub
Ib RUN
EDU01
HF
HF
CAN
485
ALARM
EDU
Inverters:
24Vdc in / 1.5 kVA out
48, 110, 220 Vdc in / 2.5kVA out
4 modules max
Inverter
+Static switch
AC output
Reserve
Manual bypass
Scalability and Pre-Configured Options
for Industrial Flexibility
Compatibility with any battery Benefits
Lead Acid
Wide output DC voltage window
Nickel Cadmium
Capability to Commission Vented NiCad cells
Vented
Recombination
System Flexibility
Wide choice of rectifying modules
Wide range of optional extras: System adaptation to meet most industrial
DC/AC inverter requirements
Dropping diodes
Monitoring solutions
…
Various Redundancy Levels
for High Availability of Power
Benefits
Several Redundancy
levels to Ensure High
Availability of the
DC load
Industrial flexibility