19A 5G Site Design Solution

HUAWEI TECHNOLOGIES CO., LTD.


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 2


Distribution RAN – Site Panorama

Features:
AAU RRU
• The fronthaul fiber between the AAU/RRU

and the BBU is shorter than 100 m.

• Application: Europe (99%), China Mobile


Clock

Site power (90%), and China Telecom (50%).


supply solution

BBU BBU cabinet


Note: The meaning of the AAU/RRU is the same as that of the RF module.
Site

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 3


Centralized RAN – Site Panorama Features:
1. BBUs are placed in a centralized manner.
 The baseband processing boards of the
AAU Clock BBUs are not interconnected.
Site power
supply solution  The baseband processing boards are
interconnected through USUs.

BBU power
2. Fronthaul fiber between the AAU/RRU and
supply solution
the BBU:
 80% within 10 km.
Fronthaul  20% ranges from 10 km to 20 km.
link
BBU
3. Application:
 Japan SoftBank (with USUs)

BBU cabinet  South Korea U+ (without USU)


 Top three tier-1 operators in China
(typically without USUs)
Site BBU concentrator  Canada Telus (typically without USUs)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 4


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 5


Introduction to the BBU5900

 BBU5900
 BBU5900 Power Module
 BBU5900 Fan Module

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 6


BBU5900
In 19A, only UBBPfw1 and UBBPfw2 are developed to support 5G.
The UBBPfw1 and UBBPfw2 are full-width boards. Therefore, the 19A must work together with the BBU5900.
The UBBPfw1 and UBBPfw2 cannot be inserted into the BBU3910 or BBU3900.

A. Purpose D. Technical Specifications D. Appearance


 Accommodates the BBU boards.
Item Specifications
Dimensions (H x W x D) 86 mm x 442 mm x 310 mm
B. Composition
Weight ≤ 18 kg (full configuration)
 One BBU5900 (by default)
Input voltage -38.4 V DC to -57 V DC
 One fan module (by default) Operating temperature -20 ºC to +55 ºC (long term)
 One power module (by default) Relative humidity 5% RH to 95% RH
 The main control board and Ingress protecting rate IP20
other service boards, such as Maximum heat dissipation capability 2100 W BBU5900 Introduction (English)

baseband processing board, are


not included.
C. Configuration Principle Note 1: The BBU5900 does not claim the short-term operating temperature.
Note 2: The heat dissipation capability depends on the fan.
 Determined based on the site
conditions.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 7


BBU5900 Power Unit
The power supply unit of the BBU5900 is UPEUe. Remarks: The UPEUe cannot be inserted into the BBU3900 or BBU3910.

A. Purpose E. Appearance
 Converts –48 V DC power into +12 V DC power.
(+12 V supplies power to the service boards through the backplane. The fan module is not supported by 12 V power
supply.)
 Provides two ports transmitting RS485 signals and eight ports transmitting Boolean signals.
(Boolean alarm signal inputs support only dry contacts and Open Collector (OC) inputs.)
(Boolean alarm signals are transmitted to the main control board through the backplane and then reported to the EMS.)

B. Composition D. Technical specifications Port Introduction


 N/A UPEUe Introduction (English)
Panel Identifier Connector Type Quantity Remarks
C. Configuration Principles EXT-ALM0 RJ45 connector 1 Port for Boolean signal inputs 0 to 3.
 The BBU5900 is delivered with one UPEUe by default.
EXT-ALM1 RJ45 connector 1 Port for Boolean signal inputs 4 to 7.
 If the power consumption of the service boards in the BBU is greater
than 1100 W (excluding the fan module), add one UPEUe. MON0 RJ45 connector 1 Port for RS485 signal input 0.
 If the power consumption of the service boards is less than 1100 W
MON1 RJ45 connector 1 Port for RS485 signal input 1.
(excluding the fan module) and the capacitor redundancy feature is
required, add one UPEUe.
 One UPEUe supports 1~8 dry contact alarms.
 If 9~16 dry contact alarms need to be reported, manually configure one
more UEIUb.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 8


BBU5900 Input Power Cable
E. Appearance
A. Purpose
 Connects the power distribution equipment and the BBU
power unit (UPEUe).

B. Composition
 One branch power cable

C. Configuration Principles (1) HDEPC connector


 Quantity: Determined based on the number of BBU (2) EPC4 connector

power modules.
One UPEUe is configured with one power cable.
Two UPEUes are configured with two power cables. (1) EPC4 connector
(1) HDEPC
(2) Scale line
 Length: Maximum 20 m. It is recommended that the connector
(3) Sliders
(2) Slider
length be within 6 m. (4) Hole for the
(3) Terminal
conductor
D. Technical Specifications

BBU5900 Power Cable Introduction (English) HDEPC Installation Guide (English) EPC4 Installation Guide (English)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 9


BBU5900 Fan Module
The BBU5900 fan module is FANf.

A. Purpose E. Appearance
 The FANf module performs the following functions:
• Dissipates heat for other boards in the BBU.
• Controls the speed of fans, monitors the temperature of fans, and
reports the status, temperature, and in-position signals of fans.
• Provides a read/write electronic label.

B. Composition D. Technical Specifications


 N/A FANf Introduction (English)

C. Configuration Principle
 The BBU5900 is delivered with one FANf by default.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 10


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 11


Power Supply Solution for the BBU5900 and the Base
Station

 Power distribution equipment


 DCDU-12B
 EPU02D-02
 APU (Newly added from November 30, 2018)
 Solution for the BBU5900 and the base stations interconnecting to the power
distribution equipment

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 12


DCDU-12B Features: The output is equal to the input.

A. Purpose
 Provides 10 DC power outputs. DC input terminals NEG(-) Two M6 one-hole OT terminals.
 The output voltage is equal to RTN(+) Maximum:
the input voltage. • One pair of 35 mm 2 cables.
• Two pairs of 25 mm 2 cables.
DC output terminal LOAD0 ~ Uses EPC5 connector. Single through-current
B. Composition LOAD5 Supports cables with the cross- capability is 30 A
 DCDU12B case 2 2
sectional area of 3.3 mm to 10 mm . (derated). 25 A is used.
 DCDU12B input power cable
 Six EPC5 connectors (delivered by DC output terminal LOAD0 ~ Uses EPC4 connector. Single through-current
default) LOAD9 Supports cables with cross-sectional capability is 30 A
 Four EPC5 connectors (delivered by area of 1.5 mm2 to 4 mm2. (derated). 25 A is used.
default)
 DCDU12B ground cable EPC5 connector EPC4 connector
D. Technical Specifications
DCDU12B Introduction (English)

E. Appearance

Install EPC5 connector (English) Install EPC4 connector (English)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 13


EPU02D-02 Features: No matter how much the input voltage is, the output is 57 V.

A. Purpose D. Technical Specifications


 Provides a maximum of four up-converting outputs and four non-up-converting outputs. EPU02D-02 Introduction (English)
 Four up-converting outputs use EPC5 connector and the output voltage is -57 V.
 Four non-up-converting outputs use EPC4 connector and the output voltage is
equal to the input voltage.

B. Composition E. Appearance
 Up converter case (EPU02D-02)
 Two up converters (BDU65-03)
 One management module (PMU12A)
 One monitoring cable (included)

C. Configuration Principles
 Length of the input power cable: 12 m by default.
(1) EPU02D series subrack
 Types of ground cables: Determined based on the region. (2) BDU65-03
 Length of the ground cable: 2 m by default. (3) PMU 12 A

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 14


Interconnection Solution Between the BBU5900 Power
Module and the Power Distribution Equipment
There are three types of power distribution equipment: DCDU-12B, EPU02D-02, and APU (to be provided from November 30, 2018).
The choice of power distribution equipment depends on the RF module of the site. Different RF modules require different power distribution equipment. For details, see
Reference.
Assume that one BBU5900 has two UPEUes.
6 EPC5 connectors 4 EPC4 connectors BDU65-03 BDU65-03 4 EPC4 connectors
DCDU-12B EPU02D-02

BBU5900 power cable BBU5900 power cable

UPEU
UPEU

UPEU
UPEU
Important notes: The external frames of EPU02D and EPU02D-02 are the same, but the two sets of equipment are different. For details, see
http://support.huawei.com.
HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 15
EPU02D-02 Monitoring Signal Cable
E. Appearance
A. Purpose
 Reports the environment variables and alarm parameters of
the EPU02D-02 to the BBU5900 power module (UPEUe).
(1) RJ45 connector
 The environment variables of the EPU02D-02 are output by
the COM port of the PMU12A. X1 End X2 End Wire Type

 The PMU12A alarm uses the RS485 serial port protocol. X1.1 X2.1
Twisted pair
X1.2 X2.2
X1.3 X2.3
Twisted pair
X1.6 X2.6
B. Composition
X1.4 X2.4
 One cable Twisted pair
X1.5 X2.5
X1.7 X2.7
Twisted pair
D. Technical Specifications X1.8 X2.8
Remarks:
EPU02D-02 and BBU monitor Cable Introduction (English) The EPU is an active device and reports alarms and status. The EPU must be
connected to the BBU.
The DCDU is a passive device and does not report alarms or status.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 16


PU
COMING SOON
2018-11-30

90%

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 17


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 18


BBU5900 Service Boards

 Main control board: UMPTe


 baseband processing board: UBBPfw1

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 19


Main Control Board UMPTe
A. Purpose
 Manages configurations and devices, monitors performance, and processes signaling of a base station.
 Processes signaling and manages resources for other BBU boards.
 Provides the USB port, transmission port, and maintenance port for signal transmission, automatic software upgrade, and BBU maintenance
on the LMT or U2000.

E. Appearance
B. Composition C. Configuration Principle
 One board main body  TBD
UMPTe Introduction (English)

D. Technical Specifications

UMPTe1: Not includes satellite card. (In the initial phase of the NR, the TDD system is used, requiring
time synchronization. The main control board that does not contain the satellite card is not
UMPTe type recommended.)
UMPTe2: Delivered outside China (including the GPS satellite card).
UMPTe3: Delivered in China (including BeiDou/GPS dual-mode satellite card).
Transmission interfaces 2 x FE/GE (electrical interface, RJ45), 2 x FE/GE/10GE (optical interface, SFP)
Transmission bandwidth (DL+UL) 10 Gbps
RAT G/U/L/NB-IoT/NR

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 20


Baseband Processing Board UBBPfw1
A. Purpose CPRI1 CPRI3 CPRI5 Silkscreen description
CPRI0CPRI2 CPRI4 CPRI4
 Provides eCPRI/CPRI port for communication
E. Appearance
with RF modules.
 Processes uplink and downlink baseband signals.
 Supports the multiplex of baseband resources 3SFP cage QSFP cage Explanation

among different modes, thereby implementing 3QSFP cage

multimode concurrency. Connector description

D. Main Parameters Cage Module

B. Composition Fronthaul interface 3SFP + 3QSFP + HEI


SFP (CPRI): 24.33024/10.1376 or lower
 Board body Supported fronthaul interface SFP (eCPRI): 25.78125/10.3125
rate (Gbps) QSFP (CPRI)*: 24.33024/10.1376 or lower
QSFP (eCPRI)*: 25.78125/10.3125
C. Configuration Principles NR (TDD)-sub 6 GHz: 3*100M 64T4R
 Configured based on BBU Supported cell bandwidth NR (TDD)-sub 6 GHz+SUL-sub 3 GHz: 3x100 MHz 64TRX + 3x10
flavors MHz/20 MHz 2R/4R
specifications. NR (TDD)-mmWave: 3x1000 MHz 4T4R
Note 1: Unit: Gbit/s
Note 2: * means that QSA support is required.
Note 3: For details about cell specifications supported by different rates, see Reference.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 21


Baseband Processing Board UBBPfw2

The UBBPfw2 board is customized for Korea.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 22


QSA
QSA is short for QSFP to SFP adapter.

Three QSAs are inserted into three QSFP cages of the UBBPfw1 and UBBPfw2. Six SFP cages are displayed
on the board.

Time when the purchased QSA is provided: 19AC9X TR5 (TBD)


Time when the Huawei-developed QSA is provided: TBD

Typical application specifications of purchased QSA:


 Convert QSFP+ (4x10.1376 Gbps@CPRI protocol) to SFP+ (1x10.1376 Gbps@CPRI protocol)
 Convert QSFP+ (4x10.3125 Gbps@ETH protocol) to SFP+ (1x10.3125 Gbps@ETH protocol)
 Convert QSFP28 (4x24.33024 Gbps@CPRI protocol) to SFP28 (1x24.33024 Gbps@CPRI protocol)
 Convert QSFP28 (4x25.78125 Gbps@ETH protocol) to SFP28 (1x25.78125 Gbps@ETH protocol)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 23


Huawei-developed QSA (2018)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 24


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 25


Uplink and Downlink Decoupling and BBU Interconnection
Solution
In dual-subrack scenarios, the uplink and downlink decoupling feature requires dual-subrack BBU
interconnection.
Dual-subrack BBU interconnection is interconnected through the CI port and the HEI port.
 CI port interconnection is the interconnection solution between main control boards in different BBUs.
 CI interconnection solution 1 - cable interconnection
 CI interconnection solution 2 - optical cable interconnection
 HEI port interconnection is the interconnection solution between baseband processing boards in different
BBUs.
 HEI interconnection solution 1 - cable interconnection
 HEI interconnection solution 2 - optical cable interconnection
Key points: This slide describes the interconnection solution for uplink and downlink decoupling.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 26


Principles of Uplink and Downlink Decoupling (SUL)
The figure on the left is used as an example.
Assume that the NR downlink is on the frequency band F2 (3.5 GHz), and
the uplink of NR and LTE are sharing the same frequency F1 (1.8 GHz).
When the NR terminal is in the short distance coverage, the uplink and
downlink of the NR terminal work on F2 (3.5 GHz).
When the NR terminal moves towards the cell edge, as the uplink coverage
of F2 (3.5 GHz) decreases, the uplink of the NR terminal is switched to F1
(1.8 GHz), and the downlink of the NR terminal is maintained at F2 (3.5
GHz). In this way, the uplink and downlink coverage areas of F2 are
effectively expanded.

High-frequency Low-frequency
coverage, for example, coverage, for For details, please refer to
3.5 GHz frequency example, 1.8 GHz
band frequency band this technical document.

Cell radius

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 27


Base Station Uplink and Downlink Decoupling Connection
Solution
Single BBU Two BBUs
Dual Star CPRI MUX Dual Star CPRI MUX
Connection Connection Connection Connection

LTE/NR LTE/NR LTE/NR RRU


NR AAU NR AAU LTE/NR RRU NR AAU NR AAU
RRU RRU

HEI interface
HEI interface

UBBP(L) UBBP(NR) UBBP(L) UBBP(NR)


UBBP(NR) UBBP(NR)
UBBP(L) UBBP(L)

UMPT UMPTe UMPT UBBP(NR)


UMPT UMPTe UMPT UMPTe

BBU5900 BBU5900 BBU39x0 BBU5900 BBU39x0 BBU5900


Uplink and downlink decoupling is implemented by a BBU CPRI-MUX connection
single BBU. BBU dual-star connection  CI port interconnection is required.
Dual-subrack interconnection is not involved.  CI port interconnection is required.  HEI port interconnection is required.

In co-subrack scenarios, the CPRI MUX connection mode is In inter-subrack scenarios, the CPRI MUX connection mode is preferred.
preferred. The CPRI MUX solution has one CPRI optical cable less than the dual-star solution.
The CPRI MUX solution has one CPRI optical cable less than Baseband processing board--LTE: UBBPd/UBBPe; NR: UBBPfw1
the dual-star solution.
Control Board--LTE: UMPT; NR: UMPTe (5G RAN2.0 supports L & NR in one UMPTe).

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 28


BBU CI Port Interconnection Solution - Background

Application scenarios:
4G BBU + 5G BBU
(inter-connection between MPT) 1. The two subracks are separate-MPT: Implement NSA (optional).
2. The two subracks are co-MPT: CI interconnection is required for the two MPTs.
BBU39x0 BBU5900
Support LTE Support NR 3. The two LNR subracks implement uplink and downlink decoupling.

LTE RRU NR AAU


BBU CI port interconnection has three solutions:
UBBP(NR)
1. If the cabling distance is less than 2 m, cables are used.
2. If the cabling distance is less than 5 m, cables are used.
3. If the cabling distance is less than 10 m, optical modules and the optical
UMPT(L) UMPT(NR)
cables are used.

The maximum interconnection distance of CI ports is 100 m. Currently,


Router or switch
only 10 m optical cables are provided.
If the interconnection distance is greater than 10 m and less than 100 m,
submit an RM workflow.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 29


BBU CI Interface Interconnection Solution 1 -Cable Solution

D. Technical Specifications Precautions:


Length: 2 m or 5 m Use only the SFP cables provided by Huawei.
Maximum rate: 10 Gbit/s Huawei-provided SFP cables are able to distinguish the root BBU from the leaf BBU.
Interface: SFP electrical connector The SFP labeled as Master must be inserted into the root BBU.
This is not an SFP optical
module, but an SFP
electrical connector.
E. Appearance

CI Interconnection Signal Cable Introduction (English) Code


Components | Accessories -BTS3900-UMPT
02231MHS
Interconnection Cable, 2.0 m
Components | Accessories -BTS3900-UMPT
02231MHT
Interconnection Cable, 5.0 m

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 30


BBU CI Port Interconnection Solution 2 - Optical Cable
Solution Single-core bidirectional optical module-SFP+-1270 nm(Tx)/1330
34060544-001 nm(Rx)-2.5~11.3 Gbit/s--8.2 dBm-0.5 dBm--14.4 dBm-LC-single mode-
10 km--40~85 degc
Single-core bidirectional optical module-SFP+-1330 nm(Tx)/1270
34060546-001 nm(Rx)-2.5~11.3 Gbit/s--8.2 dBm-0.5 dBm--14.4 dBm-LC-single mode-
B. Composition D1. Technical Specifications 10 km--40~85 degc
Optical Cable Parts-DLC/UPC-DLC/UPC-single mode-10 m-2 cores-
 Two single-fiber bidirectional optical modules Blue color ring 14136286 0.034 m/0.34 m-GYFJH-2G.657A2-7.0 mm-2 mm-LSZH-Armored
branch
 One DLC interface multi-mode optical fiber Purple color ring
D2. Technical Specifications
E1. Optical Module Appearance Length: 10 m/armored.
E2. Optical Cable Appearance
1A 2A
C. Configuration Principles
 Number of optical modules: One pair of (1) DLC connector
(2) Armored fiber optic cable
single-fiber bidirectional optical modules. (3) Branch optical cable
 Number of single-mode optical fibers on the (0.34 m on both sides)
1B 2B
DLC interface: one cable with the length of F1. Important Notes for Installation F2. Important Notes for Installation
10 m (the pigtails on both sides are 0.34 m).
Insert the blue color ring into the CI port of the
Separate A and B. You only need to use 1A and 2A.
Currently, a single-mode fiber longer than 10 m
main control board where the root BBU is
can be provided by Huawei. However, the pigtails
located.
on the two sides of the fibers are 0.34 m and
Insert the purple color ring into the CI port of
0.03 m, respectively, which is not suitable for CI
the main control board where the leaf BBU is
port interconnection.
located.
Installing BBU Interconnection Signal Cables (English)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 31


Uplink and Downlink Decoupling Solution - Dual Star

18B inter-subrack scenario: dual-star connection Scenario description:


LTE is deployed on the inventory BBU3900/3910, and NR is deployed on the newly built
BBU5900.
1.8 GHz RRU AAU5612 x 3 Constraints:
• The LTE baseband processing board must be UBBPd or UBBPe. LBBPc is not supported.
• The LTE main control board must be the UMPTa/b/e. The LMPT is not supported.
• The main control board of the LTE subrack must be connected to the CI port of the main
control board of the NR subrack.
UBBPfw1
Working principles:
UBBPd/e The CPRI data at the 1.8 GHz frequency band is sent to the LTE and the NR baseband
processing board and then goes through the LTE uplink and downlink baseband processing and
NR uplink baseband processing respectively.

UMPTx(L) CI
UMPTe(N)
Add a group of optical modules and optical cables between the RRU and the BBU.
The types of optical modules and types of optical cables are the same as those of existing LTE.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 32


Uplink and Downlink Decoupling Solution - CPRI MUX

18B inter-subrack scenario: CPRI-MUX connection Scenario description:


LTE is deployed on the inventory BBU3900/3910, and NR is deployed on the
newly built BBU5900.
1.8 GHz RRU AAU5612 x 3
Constraints:
• The LTE baseband processing board must be UBBPd or UBBPe. LBBPc is
not allowed.
• The LTE main control board must be the UMPTa/b/e. The LMPT is not
UBBPfw1
supported.
UBBPd/e • The main control board in the LTE subrack must be connected to the CI port
of the main control board of the NR subrack.

UMPTx(L) CI
UMPTe(N) The following slide focus on the red interconnection solution.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 33


BBU HEI Port Interconnection Solution 1 - Cable Solution

A. Purpose D. Technical Specifications


 The HEI ports on the UBBP are interconnected, which is
used for uplink and downlink decoupling. HEI Interconnection Signal Cable Introduction (English)

E. Appearance
B. Composition
 One QSFP port cable main body

C. Configuration Principles (1) QSFP electrical connector

 Quantity: One cable is configured between two UBBPs.


Note: Different from CI interconnection cables, HEI interconnection cables are
 Length: 2 m or 5 m. not distinguished by Master and Slave.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 34


BBU HEI Port Interconnection Solution 2 - Optical Cable
Solution

A. Purpose D. Technical Parameter


 The HEI ports on the UBBP are interconnected,
HEI Interconnection Signal Cable Introduction (English)
which is used for uplink and downlink decoupling.
E2. Appearance
B. Composition
 Two QSFP multi-mode optical modules
 One MPO multi-mode optical fiber

C. Configuration Principles
 Quantity: One cable is configured between two UBBPs.
(1) MPO connector
 Length: 10 m, 30 m, or 100 m. For any other (2) Strap
(3) MPO connector
requirements, submit an RM workflow.
Note: The optical module interconnection of HEI port is different from that
of the CI port. Color rings need to be distinguished for CI, but not for HEI.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 35


Uplink and Downlink Decoupling RF Modules and Boards
Supported by 19A
Bands & Spectrum RF Modules Control & BB Boards

Spectrum RF Module (SUL ready) xTxR


UL & DL Decoupling Bands Boards LTE 5G NR
AAU5612 64T64R
5G NR@3.5 GHz + LTE@1.8 GHz 3.5 GHz AAU5613 64T64R Control UMPTa/b/e UMPTe
AAU5313 32T32R
RRU3939 2T2R Baseband UBBPd/e UBBPfw1
LTE+5G NR SUL BW Requirement RRU3971 4T4R
RRU5901 4T4R
SUL@1.8 GHz: (1710~1875 MHz)
RRU5904 4T4R
1800
or RRU5501 4T4R
LTE+NR LTE+NR MHz UBBPfw1 supports:
RRU3959 2T2R
3x100 MHz 64T64R + 3x20 MHz 4R
15 MHz 20 MHz RRU3632 2T4R
RRU3962 2T4R 3x100 MHz 32T32R + 3x20 MHz 4R
RRU5905 2T2R

Page 36 HUAWEI TECHNOLOGIES CO., LTD.


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 37


Introduction to BBU Transmission Solution
LTE and NR co-subrack and co-MPT scenarios
Typical configuration: One UMPTe with the total bandwidth less than 10 Gbit/s is configured for NR and LTE.

LTE and NR co-subrack but separate-MPT scenarios


Typical configuration: One UMPTe with the total bandwidth less than 10 Gbit/s is configured for NR. One UMPTa/b/e with the
total bandwidth less than 1 Gbit/s is configured for LTE.

Electrical port backhaul solution: The Ethernet cable solution is used, supporting only GE.
Optical port backhaul solution: The optical module and optical cable solution (mainly introduced) are used, supporting 10GE.

Optical port backhaul solution:


Types of optical module: Single-mode SFP optical module instead of the multi-mode SFP optical module is recommended.
Optical module rate: The NR backhaul bandwidth is greater than GE. Therefore, 10GE optical module instead of 2.5GE or
GE is used by default.
Optical cable: Single-mode optical fibers are used.
 End A of the optical fiber: The DLC interface is used to insert into the SFP optical module.
 End B of the optical fiber: Provides 2xLC, 2xSC, and 2xFC interfaces.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 38


BBU Transmission Optical Module
Note 1: Single-mode optical module instead of multi-mode optical module is recommended.
Note 2: The 5G NR is configured with 10 Gbit/s transmission optical modules instead of 2.5 Gbit/s or 1 Gbit/s modules.

A. Purpose D. Technical Specifications


 Connects the main control board to  Single-mode E. Appearance
the transmission equipment.  Supported distance: 10 km
 Mandatory.  Interface: DLC
 Operating temperature: -40 ºC~85 ºC
B. Composition  Working wavelength: 1310 nm
 One SFP single-mode module  Supported rate: 9.95 Gbit/s~10.5 Gbit/s

C. Configuration Principles
 Quantity: One for each UMPT
 One user transmission backup feature can be configured.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 39


Transmission Optical Fiber
A. Purpose and Important Notes FC SC LC
Connects the transmission optical modules and transmission equipment.
If the A side of jumper is adapted to the Double-LC interface, the B side must be adapted to the customer's transmission equipment or ODF rack.

B. Composition D. Main Parameters


Optical cable body E. Appearance
N/A

C. Configuration Principles
 Quantity:
(1) DLC connector
If one optical module is required in the transmission solution,
(2) Branch optical cable
configure one optical cable.
(3) Branch optical cable label
If two optical modules are required in the transmission
(4) FC connector
solution, configure two optical cables.
(5) LC connector
 Length:
(6) SC connector
Determined based on the site survey. 10 m, 20 m, and 30 m
are provided.
 Port type:
Determined based on the ODF. FC, LC, and SC are provided.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 40


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 41


RF Modules Newly Added in 19A

 AAU5613
 AAU5313
 AAU5310
 RRU5258
 HAAU5213

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 42


AAU5613
D. Main Parameters E. Appearance
Item Specifications
A. Purpose Frequency band 3400 MHz~3600 MHz: Global/China
3600 MHz~3800 MHz: Europe
AAU5613 is the main body of the RF 3480 MHz~3689 MHz: 3UK
OBW 200 MHz
module, performing the functions of
Channel quantity 64T64R
transmitting and receiving signals.
Transmit power 200 W
Port type Two SFPs
B. Composition
Port Rate 25.78125 Gbit/s or 10.3125 Gbit/s
• AAU5613 body (including Power consumption*
installation accessories and Dimensions 795 mm x 395 mm x 220 mm
Weight 45 kg (not including mounting kits)
angle adjusting components).
Operating temperature –40 ºC to +55 ºC (without solar radiation)

C. Configuration Principle Wind resistance Front: 550 N (150 km/h)


Side: 222 N (150 km/h)
• One for one sector. Back: 515 N (150 km/h)
Operational wind speed 150 km/h
*: To achieve the claimed effectiveness, the
following four conditions should be met: 25°C, Rated wind velocity 200 km/h
50% load, 3:1 uplink/downlink configuration, and Relative humidity 5% RH to 100% RH
batch 70% modules configured.
Ingress protection rating IP65

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 43


AAU5313 Overview
D. Main Parameters
Item Specifications
A. Purpose
Frequency band 3400 MHz~3600 MHz
AAU5313 is the main body of the RF
E. Appearance
OBW 200 MHz
module, performing the function of Channel quantity 32T32R
Transmit power 200 W
transmitting and receiving signals.
Port type Two SFPs
Port rate 25.78125 Gbit/s or 10.3125 Gbit/s
B. Composition
Power consumption* 1019 W
• AAU5313 body (including installation Dimensions 699 mm x 395 mm x 195 mm

accessories and angle adjusting Weight 29.5 kg


Operating temperature –40 ºC to +55 ºC (without solar radiation)
components).
Wind resistance Front: 435 N (150 km/h)
Side: 170 N (150 km/h)
C. Configuration Principle Back: 450 N (150 km/h)
Maximum operating wind 150 km/h
• One for one sector. speed
*: To achieve the claimed effectiveness, the Rated wind velocity 200 km/h
following four conditions should be met: 25°C,
Relative humidity 5% RH to 100% RH
50% load, 3:1 uplink/downlink configuration, and
batch 70% modules configured. Ingress protection rating IP65

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 44


AAU5310 Overview
D. Main Parameters
Item Specifications
A. Purpose Frequency band 3400 MHz~3600 MHz
3600 MHz~3800 MHz
AAU5310 is the main body of the RF
OBW 100 MHz
module, performing the functions of Channel quantity 32T32R E. Appearance
transmitting and receiving signals. Transmit power 100 W
Port type Two SFPs
B. Composition
Port rate 25.78125 Gbit/s or 10.3125 Gbit/s
• AAU5310 body (including installation Power consumption* 650 W
accessories and angle adjusting Dimensions 699 mm x 395 mm x 130 mm

components). Weight 20.9 kg


Operating temperature TBD
• The AAU power cable is not included.
Wind resistance Front: 415 N (150 km/h)
• The AAU ground cable is not included. Side: 100 N (150 km/h)
Back: 425 N (150 km/h)
C. Configuration Principle Maximum operating wind 150 km/h
speed
• One for one sector.
Maximum wind speed 200 km/h
*: To achieve the claimed effectiveness, the
following four conditions should be met: 25°C, Relative humidity 5% RH to 100% RH
50% load, 3:1 uplink/downlink configuration, and Ingress protection rating IP65
batch 70% modules configured.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 45


RRU5282 Overview
D. Main Parameters
A. Purpose
Item Specifications
RRU5282 is the main body of the RF
Frequency band 3400 MHz~3600 MHz E. Appearance
module, performing the functions of 3600 MHz~3800 MHz

transmitting and receiving signals. OBW 200 MHz


Channel quantity 8T8R
B. Composition Transmit power 8x30 W
• RRU5258 body (including installation Port type Two SFPs

accessories and angle adjusting Port rate 24.33024 G/10.1376 G

components). Power consumption* 765 W


Dimensions 480 mm x 356 mm x 140 mm (without the housing)
• The AAU power cable is not included.
Weight 25 kg (without the housing)
• The AAU ground cable is not included.
Operating temperature -40 ºC to +55 ºC (without solar radiation)
C. Configuration Principle Wind resistance Front: 260 N (at 150 km/h)
Side: 75 N (at 150 km/h)
• One for one sector. Back: 260 N (at 150 km/h)
*: To achieve the claimed effectiveness, the Relative humidity 5% RH to 100% RH
following four conditions should be met: 25°C,
50% load, 3:1 uplink/downlink configuration, and Ingress protection rating IP65
batch 70% modules configured.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 46


HAAU5213 Overview
D. Main Parameters
A. Purpose Item Specifications
HAAU5213 is the main body of the RF Frequency band 28 GHz: 26.5 GHz-29.5 GHz
E. Appearance
26 GHz: 24.25 GHz-27.5 GHz
module, performing the functions of
OBW 1000 MHz
transmitting and receiving signals.
Channel quantity 4T4R

B. Composition ERIP 28 G: 65dBm@800M, 63dBm@1G


26 G: 62dBm@800M, 60dBm@1G
• HAAU5213 body (including installation
Interface type Two SFPs
accessories and angle adjusting Interface rate 25.78125 Gbit/s or 10.3125 Gbit/s
components). Power consumption* 680 W

• The AAU power cable is not included. Dimensions 585 mm x 300 mm x 152 mm (without the housing)
Weight 20 kg (without the housing)
• The AAU ground cable is not included.
Operating temperature -40 ºC to +50 ºC (without solar radiation)
C. Configuration Principle Wind resistance Front: 285 N (at 150 km/h)
Side: 110 N (at 150 km/h)
• One for one sector Back: 290 N (at 150 km/h)
*: To achieve the claimed effectiveness, the Relative humidity 5% RH to 100% RH
following four conditions should be met: 25°C,
Ingress protection rating IP65
50% load, 3:1 uplink/downlink configuration, and
batch 70% modules configured.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 47


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 48


Fronthaul Interconnection Solution Between the BBU and
AAU/RRU

 Typical Interconnection Solution


 Optical Module Selection
 Optical Fiber Selection in the DRAN Scenario
 Optical Fiber Selection in the CRAN Scenario

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 49


Typical Interconnection Solution Between the BBU and the
AAU/RRU

One group of optical modules + single optical cable Two groups of optical modules + two optical cables

AAU/RRU AAU/RRU AAU/RRU AAU/RRU AAU/RRU AAU/RRU

SFP connector

SFP connector
SFP optical module (10
Gbit/s or 25 G bit/s)
SFP optical module (10
Gbit/s or 25 G bit/s) QSA adapter

UBBPfw1 UBBPfw1

SFP x 3 QSFP x 3 SFP x 3 QSFP x 3

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 50


AAU/RRU Bandwidth Description and Optical Module
Selection
Suggestion: 1x25 Gbit/s is preferred.
Note: There are two fronthaul solutions. AAU5613/AAU5310/AAU5313 Alternative 1 Alternative 2
 Alternative 1: One group of optical modules + 100 M 1x25 Gbit/s 2x10 Gbit/s

single optical cable. 80 M 1x25 Gbit/s 2x10 Gbit/s


60 M 1x25 Gbit/s 2x10 Gbit/s
 Alternative 2: Two groups of optical modules + two
40 M 1*10 Gbit/s
optical cables (working in load-sharing mode).
RRU5282 Alternative 1 Alternative 2
100 M 1x25 Gbit/s 2x10 Gbit/s
Selection principle: 80 M 1x10 Gbit/s
 Fronthaul bandwidth 60 M 1x10 Gbit/s
 Quantity of optical fibers 40 M 1x10 Gbit/s
 Optical module cost
Example: When the total carrier bandwidth of the AAU5613 is 100 Mbit/s,
the required fronthaul bandwidth is at least 20 Gbit/s. The options are 1x25
Gbit/s or 2x10 Gbit/s, and therefore, alternative 1 is recommended.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 51


25G-SFP-Optical Module-Two-fiber Bidirectional

A. Purpose
 Connects the BBU baseband
D. Main Parameters E. Appearance
processing board and RRU/AAU.
Item Specifications
Type Single-mode Single-mode Multi-mode

B. Composition Port Double LC Double LC Double LC


Fiber type Single-mode Single-mode Multi-mode
Optical module main body
Maximum transmission 10 km 300 m (will be released in 100 m
distance November, 2018)
Supported rate 25.78125 G @ eCPRI Same as left Same as left
C. Configuration Principle 10.3125 G @ eCPRI
24.33024 G @ CPRI
For details about the quantity, 10.1376 G @ CPRI
9.8030 G @ CPRI
see RRU/AAU Bandwidth
Operating temperature -40 ºC ~ +85 ºC -40 ºC ~ +85 ºC -40ºC ~ +85ºC
Calculation.
Suggestions:
10 km single-mode optical module is recommended for short-distance scenarios before November, 2018.
300 m single-mode optical module is recommended for short-distance scenarios from November, 2018.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 52


Introduction to the 10G SFP Optical Module (Dual-fiber
Bidirectional)
A. Purpose D. Main Parameters
 Connects the BBU baseband Item Specifications
processing board and Type Multi-mode Single-mode Single-mode Single-mode
RRU/AAU. Port Double LC Double LC Double LC Double LC

B. Composition Fiber type Multi-mode Single-mode Single-mode Single-mode


Maximum 100 m 1.4 m 10 km 20 km
Optical module main body.
transmission distance
Supported rate 10.3125 G @ eCPRI Same as left Same as left Same as left
10.1376 G @ CPRI
C. Configuration Principle 9.8030 G @ CPRI
For details about the quantity, Operating -40 ºC ~ +85 ºC Same as left Same as left Same as left
see RRU/AAU Bandwidth temperature

Calculation. Suggestion: Single-mode dual-fiber bidirectional optical module is preferred in the DRAN scenario.
Note: The cost of a 10 G single-mode optical module is the same as that of a multi-mode optical module.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 53


Introduction to the 10G SFP Optical Module (Single-fiber
Bidirectional)
A. Purpose
 Connects the BBU baseband D. Main Parameters E. Appearance
processing board and RRU/AAU. Item Specifications
 It is generally used in CRAN and Type Single-mode Single-mode Single-mode Single-mode
saves optical fiber scenarios. Port LC LC LC LC
Wavelength TX=1270 nm TX=1330 nm TX=1270 nm TX=1330 nm
RX=1330 nm RX=1270 nm RX=1330 nm RX=1270 nm
B. Composition Maximum 10 km 10 km 20 km 20 km
Optical module main body transmission
distance
Supported rate 10.3125 G @ eCPRI Same as left Same as left Same as left
C. Configuration Principle 10.1376 G @ CPRI
9.8030 G @ CPRI
For details about the quantity, see
Operating
RRU/AAU Bandwidth temperature

Calculation. Suggestions: Select only when the optical fibers are limited in the CRAN scenario.
Note: The single-fiber bidirectional optical module has LC interface, rather than DLC interface.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 54


Introduction to the Optical Fiber
1 3 2 1

1. Fibers used for direct connection


Mainly used in the DRAN scenario. (1) Double LC connector
The BBU is directly connected to the AAU/RRU. (2) Branch optical cable on the BBU side (0.34 m)
(3) Branch optical cable on the RRU/AAU side (0.03 m)

2. RF module pigtail 3. BBU pigtail


1 2 2 1
4 ODF 4
3 ODF 3

Main fiber optic cable


(1) Double LC connector Provided by (1) Double LC connector
(2) Branch optical cable on the RRU side (0.03 m) customers (2) Branch optical cable on the BBU side (0.34 m)
(3) Branch optical cable on the ODF side (0.8 m) (3) Branch optical cable on the ODF side (0.8 m)
(4) Connector for adapting to the ODF (4) Connector for adapting to the ODF

Mainly applied in the CRAN scenarios.


Jumper between the BBU and the ODF: The type of the optical connector on the ODF needs to be surveyed.
Cable adjustment between the RRU/AAU and ODF: The optical connector type of the ODF needs to be surveyed.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 55


SFP Multi-mode/Single-mode Directly-connected Optical
Cable
A. Purpose and Important Notes
Generally used in the DRAN scenarios. The distance between the BBU baseband processing board and the
AAU/RRU is less than 100 m.
The CPRI link directly connects the BBU baseband processing board and the AAU/RRU. Both sides of
the optical cable are Double-LC ports.
Able to work with 10G-SFP-multi-mode/single-mode optical module or 25G-SFP-multi-mode/single-mode Double LC port
optical module.
You need to distinguish the BBU side from the AAU/RRU side during installation. Labels are attached to the
optical cables.

E. Appearance

C. Configuration Principles
 Quantity:
If one AAU/RRU is configured with one pair of optical modules, configure one optical
cable.
If one AAU/RRU is configured with two optical modules, configure two optical cables. (1) Double LC connector
 Length: (2) Branch optical cable
Determined based on the site survey. 10 types of cables ranging from 10 m to 100 m (3) Branch optical cable
are provided.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 56


Pigtails Connected to the BBU

A. Purpose and Important Notes FC SC LC


Generally used in the CRAN scenarios to connect the BBU baseband processing board and the ODF rack in the customer's equipment room.
If one side of the jumper is adapted to the Double-LC port, the other side must be adapted to the customer's ODF rack.
Able to work with 10G-SFP-single-mode optical module or 25G-SFP-single-mode optical module.

B. Composition D. Main Parameters E. Appearance


Optical cable body. TBD

C. Configuration Principles
(1) DLC connector
 Quantity: (2) Branch optical
If one AAU/RRU is configured with one pair of optical modules, configure cable
one optical cable. (3) Branch optical
If one AAU/RRU is configured with two optical modules, configure two cable label

optical cables. (4) FC connector

 Length: (5) LC connector


(6) SC connector
Determined based on the site survey. 10 m, 20 m, and 30 m are provided.
 Port type:
Determined based on the customer's ODF. FC, LC, and SC are provided.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 57


Pigtails Connected to the RRU

A. Purpose and Important Notes FC SC LC


Generally used in the CRAN scenarios to connect the AAU/RRU to the ODF rack in the customer's equipment room.
If one side of the jumper is adapted to the Double-LC port, the other side must be adapted to the customer's ODF.
Able to work with 10G-SFP-single-mode optical module or 25G-SFP-single-mode optical module.
E. Appearance
B. Composition
Optical cable body.

(1) DLC connector


C. Configuration Principles
(2) Branch optical
 Quantity:
cable
If one AAU/RRU is configured with one pair of optical modules, configure
(3) Branch optical
one optical cable.
cable label
If one AAU/RRU is configured with two optical modules, configure two (4) FC connector
optical cables. (5) LC connector
 Length: (6) SC connector
Determined based on the site survey.
 Port:
Determined based on the customer's ODF. FC, LC, and SC are provided.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 58


Recommended Fronthaul Solution for CRAN Architecture
Term Explanation:
 Gray optical modules, gray optical modules, and white optical modules: Refer to optical modules with the transmit wavelength of 1330 nm or 1550 nm.
 Colored optical module: A series of optical modules that comply with CWDM or DWDM Protocol.

Wavelength division multiplexing (WDM): Transmit multiple optical waves with different wavelengths synchronously in a single fiber.
It makes full use of the large bandwidth resources in the low loss area of the single-mode optical fiber. Using the multiplexer, it combines the optical waves of
different wavelengths at the transmit end, and then transmits the signals to the single-mode optical fiber. In the receiving part, the demultiplexer adopts the
multiplexing method of separating the optical waves of different wavelengths. Because the optical waves of different wavelengths are independent of each
other, the bidirectional transmission can be solved.
Different number of wavelengths can be multiplexed using different wavelength division multiplexers (demultiplexers or multiplexers).
According to the different channel spacing, WDM can be classified into Coarse Wavelength Division Multiplexing (CWDM) and Dense Wavelength Division
Multiplexing (DWDM).
Appendix: MO Introduction

Huawei Wireless Product Line released the DWDM passive WDM solution for wireless fronthaul from 19AC9x.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 59


HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 60
DWDM Optical Modules
80 wavelengths defined in the DWDM Protocol 48 wavelengths released by Huawei Wireless
Channel Frequency Wavelength Channel Frequency Wavelength Channel Frequency Wavelength
60 196.00 1529.55 44 194.40 1542.14 28 192.80 1554.94
59 195.90 1530.33 43 194.30 1542.94 27 192.70 1555.75
58 195.80 1531.12 42 194.20 1543.73 26 192.60 1556.55
57 195.70 1531.90 41 194.10 1544.53 25 192.50 1557.36
56 195.60 1532.68 40 194.00 1545.32 24 192.40 1558.17
55 195.50 1533.47 39 193.90 1546.12 23 192.30 1558.98
54 195.40 1534.25 38 193.80 1546.92 22 192.20 1559.79
53 195.30 1535.04 37 193.70 1547.72 21 192.10 1560.61
52 195.20 1535.82 36 193.60 1548.51 20 192.00 1561.42
51 195.10 1536.61 35 193.50 1549.32 19 191.90 1562.23
50 195.00 1537.40 34 193.40 1550.12 18 191.80 1563.05
49 194.90 1538.19 33 193.30 1550.92 17 191.70 1563.86
48 194.80 1538.98 32 193.20 1551.72 16 191.60 1564.68
47 194.70 1539.77 31 193.10 1552.52 15 191.50 1565.50
46 194.60 1540.56 30 193.00 1553.33 14 191.40 1566.31
45 194.50 1541.35 29 192.90 1554.13 13 191.30 1567.13

Frequency unit: THz Specified in the DWDM Protocol.


Wavelength unit: Nm

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 61


Optical Modules to be Delivered by October 30, 2018
Six types of 26G optical modules with fixed wavelengths are to be provided from October 30, 2018.

Three types are fixed at the BBU side (the frequency value ends with an even number).
The other three types are fixed at the RF module side (the frequency value ends with an odd number).

The optical modules on the BBU side can only send wavelengths according to 60# The optical modules on the RF module side can only receive wavelengths
196.0THz. according to 60# 196.0THz.
The optical modules on the BBU side can only receive wavelengths according to 59# The optical modules on the RF module side can only send wavelengths
195.9THz. according to 59# 195.9THz.

34061920 34061921
Optical modules must be used in pairs.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 62


Introduction to the Outdoor Multiplexer and Demultiplexer 1
On site
Outdoor multiplexer and Internal cross section
demultiplexer (IP65)

210 mm (W) * 290


mm (H) * 60 mm (D)
Optical cable description

Pole mounting kits


The diameter of the optical cable is 7 mm.
The pigtail length of the optical cable is 30 mm.

Note: Supports 14 optical fibers. Twelve optical fibers support twelve RRUs, one is a convergence optical fiber, and one is reserved.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 63


Introduction to the Outdoor Multiplexer and Demultiplexer 2
Four types of mounting bracket and four types of outdoor
Outdoor multiplexer and demultiplexer mounting bracket
multiplexer and demultiplexer support the installation of 12-
wavelength flange.
For example: Support the interconnection with the 25# to 36#
optical modules.

Four types of mounting bracket and four types of outdoor


multiplexer and demultiplexer support the installation of 24-
wavelength flange.
No. Name Quantity Material For example: Support the interconnection with the 25# to 60#
1 Mounting bracket 1 1.5 mm galvanized steel plate + powder optical modules.
2 2LC/PC adapter 12 Huawei BOM number: 14130249
3 LC/PC adapter 2 Huawei BOM number: 14300121
Note: The 12-wavelength and 24-wavelength mounting brackets differ only in
the number of flanges.

Ultimate planning: Outdoor multiplexer and demultiplexer have six BOM numbers.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 64


Indoor Multiplexer and Demultiplexer 1: Case

Support
Support
Two 24-wavelength boards + two 12-wavelength boards
Six 12-wavelength boards
One 48-wavelength board + two 12-wavelength boards

Width: 19 inch Width: 19 inch


Height: 1 U Height: 1 U

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 65


Indoor Multiplexer and Demultiplexer 2: Board
12-wavelength board has four plans.

24-wavelength board has two plans.

48-wavelength board has one plan.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 66


Introduction to DWDM Cables

Core point:

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 67


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 68


Trace Length of the DC Power Cable for the 19A RF Module
Applicable to countries outside China, China Unicom, and China Telecom Applicable to China Mobile
0~70 m 5.3 mm^2 AAU5310 China national 0~70 m 6 mm^2
American standard
AAU5310 71~100 m 8.2 mm^2 DCDU+ single-cable standards 71~100 m 10 mm^2
DCDU+ single-cable 0~70 m 6 mm^2
European standard HAAU5213 China national 0~70 m 6 mm^2
71~100 m 10 mm^2
DCDU+ single-cable standards 71~100 m 10 mm^2
0~70 m 5.3 mm^2
American standard
HAAU5213 71~100 m 8.2 mm^2 AAU5313 China national
0~100 m 10 mm^2
DCDU+ single-cable 0~70 m 6 mm^2 EPU+ single-cable standards
European standard
71~100 m 10 mm^2 China national
0~70 m 4 mm^2
AAU5313 European standard 0~100 m 10 mm^2 RRU5258 standards
EPU+ single-cable American standard 0~70 m 8.2 mm^2 EPU+ single-cable China national
71~100 m 6 mm^2
0~70 m 6 mm^2 standards
European standard
AAU5313 71~100 m 10 mm^2 China national
DCDU+ dual-cable 0~70 m 5.3 mm^2 0~70 m 6 mm^2
American standard AAU5613 standards
71~100 m 8.2 mm^2 DCDU+ dual-cable China national
0~70 m 4 mm^2 0~100 m 10 mm^2
European standard standards
RRU5258
71~100 m 6 mm^2
EPU+ single-cable AAU5613 China national To be provided from To be provided from
American standard 0~100 m 5.3 mm^2 APU+ single-cable standards November 30, 2018 November 30, 2018
RRU5258 European standard 0~100 m 6 mm^2
DCDU+ dual-cable American standard 0~100 m 5.3 mm^2
0~70 m 6 mm^2 AAU5313 and RRU5258 do not provide the DCDU+ dual-cable solution for
European standard China Mobile.
AAU5613 0~100 m 10 mm^2
DCDU+ dual-cable 0~70 m 5.3 mm^2
American standard
0~100 m 8.2 mm^2
If the trace length exceeds 100 m, the blade power supply solution can be used.
To be provided from To be provided from
European standard
AAU5613 November 30, 2018 November 30, 2018
APU+ single-cable To be provided from To be provided from
American standard
November 30, 2018 November 30, 2018

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 70


Up Converter 2.0 or EPU02D-02
A. Purpose D. Technical Specifications
 The up converter case provides two up converter slots, one management module Up converter 2.0 description (English)
slot, and four power terminals.
 Up converter: Boosts the input voltage to the -57 V.
 Management module: Connects to the BBU and communicates with the BBU.
 Four power terminals (30 A fuse): The output voltage is equal to the input voltage.
Supply power for the BBU5900.

E. Appearance
B. Composition
 Up converter case (included)
 Two up converters (included)
 One management module (included)
 One monitoring cable (included)
 Input power cable of the up converter (configuration and site survey are required)
 Ground cable of the up converter (configuration and site survey are required)

C. Configuration Principles
 Each case supports two up converters and a maximum of four AAUs/RRUs.
 Types of input power cables: Determined based on the region.
 Length of the input power cable: The default value is 12 m, which can be manually changed. (1) EPU02D series subrack
 Types of ground cables: Determined based on the region. (2) BDU65-03
(3) PMU 12A
 Length of the ground cable: The default value is 2 m.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 71


DCDU-12B + Single-cable Solution
DCDU-12B Upper-Level Circuit Breakers (English)
ODM03D Introduction (English)

DCDU-12B BBU5900
RF module

DCDU input
BBU power cable

Customer DC RF module
power ground
distribution box cable
RF module power cable

Power Interface (English)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 72


EPU + Single-cable Solution
EPU02D-02+ single-cable solution EPU02D-02 Introduction (English)

RF module
Monitoring cable
COM_IN MON0

EPU02D-02 BBU5900

DCDU input
BBU power cable RRU5258
ground
cable

Customer DC
power
distribution box RRU power cable

Power Interface (English)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 73


DCDU + Dual-cable Solution
DCDU-12B+ dual-cable solution
Function of ODM03D: Combines the dual-cable into a single-cable.
DCDU-12B Upper-Level Circuit Breakers (English) RF module
ODM03D Introduction (English)

DCDU-12B BBU5900

DCDU input
BBU power cable
RF
module
ground
cable

Customer DC
power
distribution box
RF module power cable

Power Interface (English)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 74


APU + Single-cable Solution
RF module
COM_IN Monitoring cable MON0

APU BBU5900

BBU power RF
DCDU input cable module
power cable ground
cable

Customer DC
power
distribution box
RF module
power cable

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 75


AAU5310 or AC Power Supply

AAU5310 is mainly delivered to Korea, where the Centralize RAN scenario is used.
The power supply solution of the AAU5310 must be adopted in the outdoor. Blade power supplies and blade
batteries are recommended.

Blade power supply and blade battery in the wireless configurator are OPM30 VB and TBD.
Blade power supply and blade battery in the energy configurator are DPU40D and DBU40B.

In some scenarios, the AAU power supply distance is long. When the existing DCDU-12B, EPU02D-02, or APU
does not meet the requirements, AC power supply is recommended. The power supply and battery of the AC
blade are deployed under the tower.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 76


Blade Power (Rectifier) – DPU40D/OPM30VB

(1) Power input port 90–290 V AC


(2) Load output port 1
-42 V DC to -58 V DC
(3) Load output port 2 Fuse 30A
Specification (4) Load output port 3
With PLC

Volume: 6 L (300 mm x 50 mm x 400 mm) Float charge: -54.5 V DC


(5) Battery output port
Weight: 7 kg With PLC
Rated power: 2000 W (6) COM_DIN port
Working temperature: -40 ℃ to 55 ℃ (7) COM_ALM port 4 dry contactors
Input voltage: 220 V AC single-phase (8) Ground screw
DC distribution: 3*30 A (load), 1*40 A (battery)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 77


Blade Battery – DBU40/TBD

(1) Ground screw

(2) COM_IN/OUT port

Volume: 12 L (300 mm x 120 mm x 400 mm) (3) Battery output port 1


Weight: 27 kg
(4) Battery output port 2
Working temperature: -40 ℃ to 55 ℃
Voltage: -48 V DC
Capacity: 40 Ah/2000 W

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 78


Site Configuration Solution for Blade Power Supply/Battery
(Korea)
Power Consumption per AAU5310 is (note)
The input voltage range: -36 V~ -57 V DC

AAU5310  AAU5310 power cable: For details,


see Configuration Manual.
 AAU5310 ground cable: For details,
Pole
see Configuration Manual.
 DPU40D/OPM30VB input power
Blade power and
blade battery cable: For details, see Configuration
Manual.
AC distribution box

48 V DC
220 V AC

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 79


Remote Monitoring, Maintenance and Test, and Upgrade
Solutions for Blade Power Supply/Battery
The PLC port is used for remote monitoring, maintenance and test, and
AC Input -48 V upgrade.

PLC
DBU40B • PLC (Power Line Carrier Communication) is an approach to utilize the existing power
DPU40D
lines for the transmission of information.
• By source, the signal is modulated on carrier frequency and injected onto power line.
-48 V
• By sink, the signal is filtered out and demodulated.

AAU/RRU
Channel
Source modulate filter coupling
coding
Power
BBU line
PLC
eCPRI/CPRI Channel
Sink demodulate filter coupling
decoding

EMS
PLC communication block diagram

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 80


The Maintenance and Test Function of the Remote EMS
for Blade Power Supply/Battery Real-time data
Battery Status
Voltage
Part Name
POWER SYSTEM
POWER SYSTEM
Alarm
AC Failure
AC Overvoltage
Battery Current POWER SYSTEM AC Undervoltage
Battery Remain Capacity POWER SYSTEM DC Overvoltage
Temperature
The EMS provides various maintenance and test Total Discharge Power
POWER SYSTEM DC Undervoltage
POWER SYSTEM Input DC Overvoltage
Battery Backup Time
functions for blade power supply and battery. Battery SOH
POWER SYSTEM Input DC Undervoltage
Total Capacity POWER SYSTEM Parallel Fail
Battery Voltage POWER SYSTEM Address Conflict
Battery Current POWER SYSTEM HVDC Failure
No Monitoring Function Cell Voltage Rectifier Module Rectifier Fault
Cell Temperature Rectifier Module Rectifier Protection
1 Alarm Management Capacity Rectifier Module Communication Failure
Slot No. Rectifier Module Rectifier Power Failure
2 Battery Management Operating Status Rectifier Module Rectifier Overvoltage
DC Output Voltage Rectifier Module Inverter Fault
3 Running Information DC Output Current
DC Output Power
Rectifier Module Inverter Protection
Rectifier Module SPD Fault
4 Parameter Setting Remotely AC Voltage
Real-time Efficiency
Battery Cell ESMU Communication Failure
Battery Cell Board Hardware Fault
Rectifier Temp.
5 Inventory Management Cur. Limiting Status
Battery Cell Low Temperature
Bar Code Battery Cell Low Temperature Protection
6 Report Management E-Label Battery Cell Discharge High Temperature Protection
Rated Output Current Battery Cell Charge High Temperature Protection
7 Software Upgrade Remotely Module Type Battery Cell Overcharge Protection
Input DC Voltage Battery Cell Overdischarge Protection
Total Output Current Battery Cell Battery Electrochemical Cell Fault
Total DC Power Battery Cell Address Conflict
PSU Group Sample Valid Num Battery Cell Upgrade Failed
Total AC Power Battery Cell Overcharge
Rectifier Amount Battery Cell Overdischarge
System Voltage Battery Cell Charge Overcurrent
Total Load Current Battery Cell Charge Overcurrent Protection
AC Voltage
Battery Cell Discharge Overcurrent
AC Current
Battery Cell Discharge Overcurrent Protection
AC Frequency
Parallel Status Battery Group All ESMU Communication Failure
Mains Power Consumption Battery Group Battery Discharge
DC Load Power Consumption Battery Group Battery Charge Overcurrent
HVDC Voltage Battery Group High Battery Temperature
HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. HVDC Current PageBattery
81 Group Low Battery Temperature
HVDC Failure Status Battery Group ESMU Missing
Support Third-Party Power and Battery
···
Reasons:
1. The third-party power supply and
battery cannot provide the PLC
Third-part MEB
function. power supply
2. The AAU5310/RRU5282 does not
provide the physical alarm interface.

CPRI/eCPRI
Results:
1. The MEB alarm cable needs to be
added.
2. The MEB supports six dry contact
alarms. Dry contact
alarm cable
EMS

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 82


MEB Alarm Cable

To third-party
power supply To MEB

Dry Contact Color Remarks


X2 White and blue Boolean input 0+
X3 Blue Boolean input 0- (GND)
X4 White and orange Boolean input 1+
X5 Orange Boolean input 1- (GND)
Power
X6 Red and blue Boolean input 2+
Power Output
X7 Blue Boolean input 2- (GND)
Input
X8 Red and orange Boolean input 3+
X9 Orange Boolean input 3- (GND)
ALM X10 Red and green Boolean input 4+
Port X11 Green Boolean input 4- (GND)
X12 Red and Brown Boolean input 5+
X13 Brown Boolean input 5- (GND)

For third part power supply, Support 6 dry contract alarms

83 Huawei Confidential
Specifications of MEB-06D

Item Specification
Dimensions (H x W x D) 240 mm x 86 mm x 60 mm
Weight 1.3 kg (2.87 lb)
Input power -48 V DC;
voltage range: -36 V DC to -57 V DC
Rated current 40 A
Power consumption 5W
Ambient temperature (long-term • With solar radiation of 1120 W/m ²: -40 ℃ to +50 ℃
operation) • Without solar radiation: -40 ℃ to +55 ℃
Relative humidity 5% RH to 95% RH
Ingress protection (IP) rating IP65

• Working normally when the wind speed is 45 m/s or lower


Wind resistance
• No damage when the wind speed is 55 m/s or lower
MEB-06D
Noise None

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 84


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 85


5G Time Synchronization Requirements: Reference Source
Synchronization Precision between Base Stations ≤±1.5us

Neighboring eNB D D S U D D
Impacts and requirements of NR (TDD) base station clock source faults:
Interference
 Downlink interferes uplink between base stations -> Inter-base station out-of-synchronization
Faulty eNB D D S U D D tolerance time
 Downlink interferes uplink between UEs -> Inter-UE guard interval

TSync <= Min(TDL_UL- Tprop_BS2BS-TBS on off, TAoffset - TBS off on )

Synchronization requirement Typical


RAT Sub-carrier Factors affecting synchronization
Min (between base stations and between UEs) service
Downlink to uplink: Gap~70us; Uplink to downlink: TAoffset 20us; Between base stations: 3us; Absolute precision:
SC=15K(Sub 6G) Basic service
TBS off on 17us ±1.5us
Downlink to uplink: Gap~35us; Uplink to downlink: TAoffset 13us; Between base stations: 3us; Absolute precision:
NR(TDD) SC=30K(Sub 6G) Basic service
TBS off on 10us ±1.5us
Downlink to uplink: Gap~8.9us; Uplink to downlink: TAoffset 6us; Between base stations: 3us; Absolute precision:
SC=120K(Sub 6G) Basic service
TBS off on 3us ±1.5us
Between base stations: 3us; Absolute precision:
LTE(TDD) - Downlink to uplink: Gap~70us; Uplink to downlink: TBS off on 17us Basic service
±1.5us

The clock synchronization specifications of 5G NR (TDD) are basically the same as those of LTE
TDD: ±1.5us

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 86


Five Time Synchronization Solutions for 5G NR (TDD)

To mainly use GPS To mainly use 1588v2


1588v2 (core layer BITS)
3 1588v2 is enabled on the entire bearer network.

GPS 1588v2 (access layer BITS)


1 Deploy the GPS at the site. 4 From lower-layer of the BITS to the core
layer. 1588v2 is enabled on the access ring.

GPS is mainly used, and 1588v2


2 1588v2 (core layer + access layer BITS)
(core BITS) is added. 5
Phrase 1: IEEE 1588v2 is enabled on the
Phrase 1: The GPS is deployed
access ring.
at the site.
Phase 2: 1588v2 is enabled on the entire
Phase 2: 1588v2 is enabled after
bearer network
the bearer network is mature.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 87


Time Synchronization Solution 1: Single GPS Solution

GPS satellite/BeiDou satellite Solution introduction: Deploy the GPS at the site.
Solution features
 Precision: The base station obtains the air clock source
directly, so the precision is high.
 Reliability: There is no single point of failure, and the
impact scope is small.
 Security: Only use the air clock source, which brings
security risks.
 Deployment period: Deployed at the site, so the
deployment period is relatively short.
 O&M: Easy to locate the fault.
 Cost: GPS is required for each site, so the hardware
cost is high.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 88


Suggestions on 5G Clock Deployment Solution
For details, see the attachment.

Preferred choice Second choice


LTE(TDD/FDD) The GPS is mainly used, and GPS only.
With existing 1588v2 is added. (Condition: Sensitive to network construction
GPS available (Core layer BITS) costs.)

Dual-layer 1588v2 (core layer BITS+ access


network BITS)
(Condition: Sensitive to security, and the
LTE(FDD) The GPS is mainly used, and 1588v2 network is mature.)
With existing 1588v2 is added.
GPS unavailable (Core layer BITS)
GPS only
(Condition: Insensitive to security, but sensitive
to costs)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 89


GPS Time Serving Solution
A. Purpose D1. Main specifications of the GPS antenna D2. Main specifications of the D3. Main
 Provides time GPS surge protector specifications of GPS
synchronization. Frequency range (MHz) 1575.42±5
Rated working voltage 5 VDC
mounting bracket
Gain (dBi) 38±2 (including LNA)
Fixing hole spacing:
DC power supply voltage 4V~6V Rated working current 3A
B. Composition 150 mm x 150 mm
Nominal discharge current
 GPS antenna Power supply current ≤45 mA 10 kA Height of the GPS
In (8/20μs)
 GPS surge protector Antenna interface mode N(Female) mounting bracket:
Maximum discharge
 GPS mounting bracket Antenna dimension current Imax (8/20μs)
20 kA 2m
96 mm × 112 mm
 Installation auxiliary (Diameter x height) Voltage limit (8/20μs20kA) ≤15 V
equipment package and Antenna weight 0.20 kg 1200 MHz ~
D3. Appearance of
so on. Working frequency the GPS mounting
2600 MHz
Operating temperature -40 ℃ ~ 85 ℃
Insertion loss ≤0.2 dB bracket
Saving temperature -55℃ ~ 85 ℃
C. Configuration Port type (Input/Output) N(F)/N(M)
Operating humidity 95%
Principles Operating wind speed 140 km/h
 New built 5G base
Maximum wind speed 200 km/h
station:
Configure a set of GPS E1. Appearance E2. Appearance
installation suite.
 If the installed base
station has GPS, you
can skip this step.
GPS antenna installation (English)

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 90


Contents
 Site Panorama
 Introduction to the BBU
 Power Supply Solution for the BBU and Base Station
 Introduction to the BBU Service Boards
 Uplink and Downlink Decoupling and BBU Interconnection Solution
 BBU Transmission Solution
 NR RF Module Newly Added in 19A
 RF Module Fronthaul Solution
 RF Module Power Supply Solution
 Clock Solution
 Others

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 91


RRU5258 Top of Cabinet Jumper Package

A. Purpose E. Appearance
D. Technical Specifications
 Connects the RF output port of the The cables of 2 m, 3 m, 4 m, 6 m, and 10 m are 4.3-10 female
RRU and the antenna. available.

There are three types of cables:


N male (RRU5258 side) -N male (selected according
to the antenna system)
B. Composition
N male (RRU5258 side) -7/16DIN male (selected
 Nine cold shrink tubes N female
according to the antenna system)
 Two auxiliary equipment packages
N male (RRU5258 side) -4.3-10 male (selected
 Nine RF jumpers
according to the antenna system)

There are three types of auxiliary equipment package:


For general area, cold area, and India. DIN female
C. Configuration Principles
 Each RRU5258 is configured with one top of cabinet jumper package.
 Types of RF jumper: Determined based on the antenna RF connector.
 Length of the RF jumper: Determined based on the distance between the antenna and the RRU.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 92


Cabinet Solution

 For details, see the 18B cabinet solution.

 For details, see the 19A cabinet solution.

HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 93


Thank you
www.huawei.com

Copyright © 2018 Huawei Technologies Co., Ltd. All Rights Reserved.


The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and
operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to
differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and
constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.