0 valutazioniIl 0% ha trovato utile questo documento (0 voti)
19 visualizzazioni22 pagine
The electrical system of a 15 MW CFB power plant includes a single bus system with the generator paralleled to a 34.5 kV bus. There are 4.16 kV and 460 V station service buses. The generator is a 15 MW brushless turbogenerator that operates at 1800 rpm and is air cooled. For parallel operation, the generator and transformers must have the same phase sequence, voltage, frequency, and phase position. The main transformer steps up the 13.8 kV generator voltage to 34.5 kV, and auxiliary transformers provide lower voltages.
The electrical system of a 15 MW CFB power plant includes a single bus system with the generator paralleled to a 34.5 kV bus. There are 4.16 kV and 460 V station service buses. The generator is a 15 MW brushless turbogenerator that operates at 1800 rpm and is air cooled. For parallel operation, the generator and transformers must have the same phase sequence, voltage, frequency, and phase position. The main transformer steps up the 13.8 kV generator voltage to 34.5 kV, and auxiliary transformers provide lower voltages.
The electrical system of a 15 MW CFB power plant includes a single bus system with the generator paralleled to a 34.5 kV bus. There are 4.16 kV and 460 V station service buses. The generator is a 15 MW brushless turbogenerator that operates at 1800 rpm and is air cooled. For parallel operation, the generator and transformers must have the same phase sequence, voltage, frequency, and phase position. The main transformer steps up the 13.8 kV generator voltage to 34.5 kV, and auxiliary transformers provide lower voltages.
ELECTRICAL SYSTEM Overview • The electrical system is designed as single bus • The generator parallel in 34.5 kV bus • 4.16 kV station service bus • Operation section • Standby section ELECTRICAL SYSTEM Overview • 460 V station service bus • Low voltage station service bus • Coal conveying bus • Chemical water treatment bus • Low voltage station standby bus • Coal conveying standby bus • Coal water treatment standby bus • Emergency section bus ELECTRICAL SYSTEM ELECTRICAL SYSTEM ELECTRICAL SYSTEM ELECTRICAL SYSTEM Generator • Model: QFW-15-4 • Brushless Turbogenerator • Output power 15 MW / 18.75 MVA • 4 poles • Rotating Direction: CCW viewing from Turbine to Generator • Rated Voltage: 13.8 kV • Rated Current: 784 A ELECTRICAL SYSTEM Generator • Rated Speed: 1800 rpm • Armature winding is wye-connected • Cooling Type: Air Cooled ELECTRICAL SYSTEM Components of Generator • Field • Consists of coils of conductors within the generator that receive a voltage from a source and produce a magnetic flux • Armature • Part of a generator in which voltage is produced • Carry the full load current of generator ELECTRICAL SYSTEM • Prime Mover • Used to drive the generator • Type of rotating machine such as a diesel engine, a steam turbine • Rotor • Rotating component of the generator • Driven by prime mover • The rotor will be armature if the voltage output is generated there, the rotor will be the field if the field excitation is applied there ELECTRICAL SYSTEM ELECTRICAL SYSTEM Parallel Operation Conditions of Generator • Same phase sequence with system • Equal voltage with system • Same frequency with system • Same phase position with system ELECTRICAL SYSTEM Main Transformer • Model: S20000/34.5 • Rated Power: 20,000 kVA • Rated Voltage: (34.5±2x2.5%)/13.8 kV • Rated Current: 334.7/836.7 A • Vector Group: YnD5 • Cooling Type: ONAN ELECTRICAL SYSTEM ELECTRICAL SYSTEM High Voltage Auxiliary Transformer • Model: S11-3150/13.8 • Rated Power: 3150 kVA • Rated Voltage: (13800±2x2.5%)/4160 V • Rated Current: 131.8/437.2 A • Vector Group:DYn5 • Cooling Type: ONAN ELECTRICAL SYSTEM ELECTRICAL SYSTEM Start-up/Standby Transformer • Model: S11-3150/34.5 • Rated Power: 3150 kVA • Rated Voltage: (34500±2x2.5%)/4160 V • Rated Current: 52.7/437.2 A • Vector Group: YnYn10+D • Cooling Type: ONAN ELECTRICAL SYSTEM ELECTRICAL SYSTEM ELECTRICAL SYSTEM ELECTRICAL SYSTEM ELECTRICAL SYSTEM Parallel Operation Conditions of Transformer • Same vector group • Same ratio of transformation • Equal Impedance Voltage • Same phase sequence