Sei sulla pagina 1di 20

ENGINEERING COLLEGE JHALAWAR

An autonomies collage of state government Rajasthan

A
Power Point Presentation
On
Kalisindh Thermal Power
Project

SUBMITTED TO:- SUBMITTED BY:-


Mr. ASHISH KHANDELWAL KARTIK MEHTA
Dept. of electrical engineering B.TECH – (VII sem.)
Roll-17EEJEE200
AN OVERVIEW OF KATPP
CONTENTS

1. INTRODUCTION
2. WORKING PRINCIPAL
3. BOILER
4. TURBINE
5. GENERATOR
6. TRANSFORMER
7. COOLING TOWER
8. SWITCHYARD
INTRODUCTION

LOCATION- Nimoda Village


CAPACITY- (2*600)Mw
WATER SOURCE- Kalisindh River
FUEL SOURCE- Chhattisgarh
AREA- 564 Hq.
WORKING PRINCIPAL
Kalisindh supper thermal power plant work on the principal or rankine cycle.
1-2 pressurisation of water
2-3 heat addition in boiler to boil water
4-5 raising the steam to super heat condition
5-6 Expansion in turbine in HPT
6-7 Reheating
7-8 Expansion in turbine in IPT and LPT
8-1 condensation of steam to get original water
BOILER

Fig -line diagram of water tube boiler

• Boiler is a device used for producing steam


• Boiler used in KATPP is water tube boiler
• Height- 97m
• Boiler motor rating- 15KW
Fig- supporting structure of boiler in KaTPP

Manufacturing CQ.GEAR BOX LTD.CHINA


Motor rating 15 KW
Speed 970 R.P.M.
Rated voltage 416 V
Rated current 28.4 A
STEAM TURBINE

• There are three types of turbine are


o High pressure
o Intermediate pressure
o Low pressure
STEAM CYCLE
GENERATOR

• An electrical generator is a machine which converts


mechanical energy into electrical energy through electro
mechanical energy conversion
• RATINGS- 706MVA, 18.525KA, 22KV, 0.85 lagging p. f.
• COOLING- hydrogen cooling
TRANSFORMER
The transformer used in kalisindh thermal power station is-
• Generating transformer
• Unit transformer
• Unit auxiliary transformer
• Unit service transformer
• Unit station transformer
• Current transformer
• Potential transformer

GT- 250MVA, 22kv/400kv


UT- 80MVA, 22kv/11kv
COOLING TOWERS

• A cooling tower is a heat rejection


device that rejects waste heat to the
atmosphere through the cooling of a
water stream to a lower temperature.
• In KaTPP two natural draught cooling
tower is present.
• height - 202 meter
400kv SWITCHYARD
SWITCHYARD
• Switchyard provide the facilities for switching,
protection & control of electric power

 Bus bar
 Circuit breaker
 Lighting arrester
 Isolator
 Current transformer
 Voltage transformer
 Wave traper
LIGHTING ARRESTER

These are equipment designed


to protect
insulators of power lines
CIRCUIT BREAKER

SF6 CB is used.
Rated for 420 & 245 kv,
3150A and 50Hz
ISOLATER
 pantograph Isolator used in this plant.
WAVE TRAP OR LINE TRAP
It blocks the high frequency carrier waves (24KHz to 500KHz)and power waves (50Hz to
60Hz) to pass through it.
Basically an inductor of rating in mille Henry.
OUT GOING LINE FROM KATPP

kaTPP
SWITCHYARD

400KV 220KV
BATAWADA 400KV JHALAWAR
220KV
BATAWADA JHALAWAR
Thank you