Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
www.huawei.com
Network Product Service Department
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 2
OptiX OSN 9800 Products
Specifications
U64: 2200 (H) x 600 (W) x 600 (D) (the subrack is integrated into a cabinet)
Hardware
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 3
OptiX OSN 9800 Products
Specifications
1900 (H) x 498 (W) x 295 (D) (without cabinet)
N63B, N66B Cabinet
Hardware
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 4
OptiX OSN 9800 Products
Specifications
847 mm (H) x 442 mm (W) x 295 mm (D)
N63B, N66B Cabinet 19-inch rack
Hardware
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 5
Slot Assignment
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 6
U16 9800
Fan Assembly
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page77
Page
U16 9800
PIU Board
AC PIU:
Supports a maximum of 60 A power distributio
n using OT terminals
Forms a hot backup using the active and stan
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page88
Page
UPS Subrack
UPS Subrack Design
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page99
Page
Contents
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 10
OSN9800 U16
• Dimension: 840mm (19RU )Height *442mm width*295mm depth
1+1 Fan Tray
• Compatible with 19inch or ETSI Rack installation
1+1
CTU
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 11
Contents
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 12
OTU Naming Rule
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 13
Tributary Units
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 14
Line Units
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 15
OptiX OSN 8800: Cross-Connect Units
List of boards
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 16
OptiX OSN 9800: Cross-Connect Units
UXCS :
Cross-connects a maximum of 5.6 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4 or flex) sign
als.
Performs packet switching of a maximum of 2.8 Tbit/s Ethernet services.
Cross-connects a maximum of 1.12 Tbit/s VC-4 signals.
Each service slot provides a cross-connect capacity of 400 Gbit/s.
Switching mode:
Auto switching, manual switching, and forced switching are supported.
Revertive switching is supported.
An UXCS board can be locked in a working or protection state
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 17
OptiX OSN 9800: Cross-Connect Units
TNS1UXCS
Back up Mode For the OptiX OSN 9800 U32/U16: M + N = 7, M ≤ 2.
Occupies one slot in the subrack (IU71-IU77)
Indicators
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 18
OSN9800 : OUT Unit(TNU2N401T53)
100Gbit/s Line Board
N401 : 100Gbit/s Line Board
Supports backplane cross-connections of 80 ODU0, 40
ODU1, 10 ODU2, 10 ODU2e, 2 ODU3, 1 ODU4, or 80 ODUf
lex signals from/to the cross-connect board
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 19
OptiX OSN 9800: Communication Units
CTU:
Manages NE configurations and offers NE alarm outputs.
Supports the backup of NE data. When the NE data changes, the real-time
database backup function immediately saves the changed configuration data into
the storage medium to ensure that no configuration data is lost after the NE is
reset (cold) or powered off. This NE data backup improves the reliability of the NE.
Supports IP over DCC.
Supports active/standby backup. Usually, two CTU boards are configured in a
subrack for 1+1 protection. If the active CTU board fails, the standby CTU board
automatically becomes active.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 20
Optical MUX/DEMUX Units
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 21
Optical MUX/DEMUX Units
D40/D40V
Supports C-band odd or even wavelengths.
Supports in-service optical power monitoring (10 dB).
Adjusts optical power of each channel of signals (D40V).
Optical splitter
IN D40V
MON AWG
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 22
Optical Multiplexing/Demultiplexing Units
FIU FIU
STAT
ACT
PROG
MON
OSC
O U T IN
TM
TC
TC
RC
IN
WDM
TM
RM
Main optical channel Optical splitter WDM side
RC OUT
WDM
MON
RM
FIU
OSC
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 23
Optical Amplifier Units
List of boards
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 24
Optical Amplifier Units
TN11OAU1 OAU1
STAT
ACT
PROG
LASER
RADIATION
DO NOT VIEW DIRECTLY
WITH OPTICAL
INSTRUMENTS
CLASS 1M LASER
PRODUCT
MON
Supports the gain lock function.
OUT
Supports transient state control.
IN
TDC
PDC
Supports performance and alarm monitoring
OAU1
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 25
Optical Amplifier Units
TN11OAU1
Functional block diagram of modules
OAU1
Optical splitter
1 2 5 3 4
PA BA OUT
IN VOA
MON
TDC RDC
DCM
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 26
Optical Amplifier Units
OBU1 OBU1
STAT
ACT
PROG
MON
O U T IN
TN12OBU1 Optical TN11OBU1 Optical
splitter splitter
B OUT B OUT
IN
VO A MON IN A MON OBU1
VI
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 27
SCC Units
TN51/TN52SCC
SCC
The TNK2SCC board is only used in the OptiX OSN 8800 T64E subra
ck.
The TN51/TN52SCC board is only used in the OptiX OSN 8800 T32E
subrack.
Cross-connects services in the subrack, manages configurations, an
d outputs alarms.
Supports SCC data backup and data backup of the external CF card. TNK2SCC
Supports IP over DCC.
Supports 1+1 hot backup.
Provides clock source for system communication.
Supports cascading of subracks.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 28
SCC Units
SCC
LED (SubRACK_ID)
0 indicates that the subrack that houses the board is a master sub
rack.
1–1F indicates that the subrack that houses the board is a slave s
ubrack.
EE indicates that AUX is offline and the subrack ID is unavailable.
Buttons
Used to test LEDs. When you press the LAMP TEST button, all
LAMP TEST LEDs on the current subrack will be on.
For T64 For T32
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 29
SCC Units
AUX
Provides the Ethernet communication port and m
anagement port, and inter-subrack communicatio
n port.
Does not provide external ports.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 30
Optical Monitoring Units (ST2/HSC1/SC2)
ST2/HSC1/SC2
Receives or transmits and processes one or two channels of OSC signals.
Ensures that the OSC performance is not affected when the line amplifier fails.
Be relatively independent of the SCC board. In other words, when the SCC board is unavailable
on an NE, the ST2/HSC1 board can implement ECC communication with the ST2/HSC1 board o
n the upstream or downstream NE, ensuring that the connected NEs are under monitoring.
Transmits signals by span and has 3R functions.
When ST2 works with SFIU, the RM1/TM1 working wavelength is 1511 nm and the RM2/TM2 wo
rking wavelength is 1491 nm. When ST2/HSC1 works with FIU, the working wavelength is 1511 n
m.
ST2 supports transparent transmission of two channels of electrical FE signals.
ST2 supports the 1588v2 clock feature.
ST2 supports transmission over a span with a maximum of 40 dB loss and HSC1 supports trans
mission over a span with a maximum of 53 dB loss.
Supports loopback.
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 31
Other Units
Variable optical attenuator unit VA1/4 One-/four-channel variable optical attenuator board 1
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 32
Thank you
www.huawei.com
Copyright © 2013 Huawei Technologies Co., Ltd. All rights reserved. Page 33