Sei sulla pagina 1di 7

0 50 150 250 350 450 1277

SKEW 90

WELD
WELD

C E

SKEW 270

FLAW DETAILS
DEFECT LENGTH mm HEIGHT mm LOCATION DEPTH mm TYPE OF FLAW A STAR TESTING & INSPECTION (M) SDN. BHD.
FROM “0” mm
No121, Jalan Kempas 1, Taman Desaru Utama,
A 7.5 2.5 50 0 TOE NOTCH 81930 Bandar Penawar, Johor
THIS DOCUMENT AND INFORMATION HEREIN IS THE
B 10 3 150 16 SWLOF PROPERTY OF A-STAR TESTING & INSPECTION AND
MUST NOT BE USED OR REPRODUCED WITHOUT
C 10 3 250 20 SLAG PRIOR WRITTEN PERMISSION

D 10 3 350 16 SWLOF
E 7.5 2.5 450
QUALIFICATION 40.4940.49mm ROOT NOTCH
BLOCK ATI-VAL-16"-THK
NOTE: ALL DIMENSIONS ARE IN "mm"
WPS - PROFILE

37.5® 37.5®

SKEW 90 SKEW 270

40.49

1.5

QUALIFICATION BLOCK ATI-VAL-16"-THK 40.49mm


A – TOE NOTCH

SKEW 90 SKEW 270

HEIGHT
THICKNESS

QUALIFICATION BLOCK ATI-VAL-16"-THK 40.49mm


B - SWLOF

SKEW 90 SKEW 270

DEPTH
THICKNESS

HEIGHT

QUALIFICATION BLOCK ATI-VAL-16"-THK 40.49mm


C - SLAG

SKEW 90 SKEW 270

DEPTH
THICKNESS

HEIGHT

QUALIFICATION BLOCK ATI-VAL-16"-THK 40.49mm


D - SWLOF

SKEW 90 SKEW 270

DEPTH HEIGHT
THICKNESS

QUALIFICATION BLOCK ATI-VAL-16"-THK 40.49mm


E – ROOT NOTCH

THICKNESS SKEW 90 SKEW 270

DEPTH

HEIGHT

QUALIFICATION BLOCK ATI-VAL-16"-THK 40.49mm

Potrebbero piacerti anche