Page 1
TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS (CHINA) CORPORATION
Index
1. 光伏系统及逆变器介绍 Introduction to PV System and Inverter

2. 逆变器相关警示图标 Inverter Warning Signs

3. 逆变器外观及结构介绍 Inverter Appearance and Structure

4. 逆变器电气连接 Inverter Electrical Connection

5. 逆变器的运行操作 Operating the inverter

6. 逆变器的运行状态信息 Inverter Running Status Information

7. 定期检查维护注意事项 Considerations of Regular Check and


Maintenance

Page 2
TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION
1. 光伏系统及逆变器介绍 Introduction to PV System and Inverter

Integrated AC breaker
PV module PV sub-array Fuse Integrated DC box

PV sub-array 2

PV sub-array 3

PV sub-array 16

Power Grid

Combiner Box
PV string Inverter

DC system AC system

Page 3
1. 光伏系统及逆变器介绍 Introduction to PV System and Inverter

光伏阵列将太阳能转变成直流电能,经逆变器的逆变后(直-交),接入变压器,经升压后,接入
中压或高压电网。
The Photovoltaic module converts solar energy into electric energy in the form of DC
energy. Converted again by the inverter, it becomes AC energy, flowing into the
transformer, then being boosted and injected into Medium or High Voltage Power
Grid.

逆变器是光电能量转化中的核心。
The inverter is key part of process of the photoelectric conversion.

Page 4
1. 光伏系统及逆变器介绍 Introduction to PV System and Inverter

Inverter
PV array

光伏逆变器的核心功能 Core functions of the inverter


◎ MPPT跟踪 ◎ MPPT tracking
◎ 直流转交流 ◎ DC to AC
◎ 并网(电网适应性) ◎ connect to grid (grid
adaptability)

Page 5
2. 逆变器相关警示图标 Inverter Warning Signs

请务必注意逆变器柜体相关警示标语!请认真阅读产品使用手册!
Please pay attention to the warning signs on inverter cabinet! Please read the
product manual carefully!

警告:警告标志表示有潜在的危险情况或条件,若不避免,会导致人员伤亡。
Warning: warning sign indicates potential dangerous situations or conditions
that, if not avoided, can result in loss of life or injury.

小心:小心标志表示有潜在的危险情况或条件,若不避免,会造成人员受伤或设备损坏。
Caution: caution sign indicates a potential dangerous situations or conditions
that, if not avoided, can result in injury to a person or damage to equipment.

注意:注意标志表示客户或维护人员在逆变器运行或维护工作时需要仔细观察。
Note: the sign indicates that a customer or maintenance personnel need to
carefully observe the inverter when it is running or under maintaining.

禁止:禁止标志表示客户或维护人员无论在逆变器安装、运行或维护时,都不能采取的行为。
Prohibited: A prohibited sign indicates the behavior that a customer or maintenance
personnel cannot take, regardless of the installation, operation, or maintenance of
the inverter.

Page 6
3. 逆变器的外观与结构介绍 Inverter Appearance and Structure

外观 Appearance 内部结构图
Construction
Input cabinet Inverter unit cabinet Output
cabinet

尺寸 Size: W2700xD730xH2075 直流输入 DC Input: 12-16 MCCB


重量 Weight: 2200kg 逆变柜inverter unit :Mitsubishi IGBT
输入 Input: 12-16 MCCB 交流输出 AC output: Mitsubishi AC
Breaker

Page 7
3. 逆变器的外观与结构介绍 Inverter Appearance and Structure
输入柜 Input cabinet 逆变柜 Inverter unit 输入柜 Output
cabinet cabinet

Page 8
3. 逆变器的外观与结构介绍 Inverter Appearance and Structure

电抗器 Reactor 备用电源 Backup power

Page 9
3. 逆变器的外观与结构介绍 Inverter Appearance and Structure

控制变压器 Control transformer 逆变器散热风机 Cooling fans

Page 10
4. 逆变器电气连接 Inverter Electrical Connection

接输入直流正极
connect to DC
1、直流输入侧接线 input positive
DC input wiring wire

打开输入柜,拆下防护罩挡板,接线时注意电
源的正负极,正极接开关上的+极,负极接开
关上的-极,压接端子紧固牢靠。
Open the input cabinet, remove the
protective cover. When wiring, please
pay attention to the polarity, positive
wire connects to +; while negative wire
connects to -. Terminal must be
tightened. 接输入直流负极
connect to DC
注:正负极直流电缆进入直流柜时请务必采
用前后分开接线! input negative
NOTE: when connecting the positive wire
and negative wire to the DC cabinet,
please be sure to use the front and
rear wiring!

Page 11
4. 逆变器电气连接 Inverter Electrical Connection

2、交流输出侧接线
AC output wiring

打开输出柜,拆下防护罩挡板,母线相序对
接逆变器上的相序连接,压接螺栓紧固牢靠
并做好紧固记号。
Open the output cabinet, remove the
protective cover. Bus phase sequence
connects in accordance with the phase
sequence of the inverter. Screw
tightening and make signs.

Page 12
4. 逆变器电气连接 Inverter Electrical Connection

3、逆变器控制电源接线
Inverter control power wiring Control power
AC220V
打开输出柜,拆下防护罩挡板,在输出柜的右侧下方
有控制接线端子,接线端子上1—2为控制电源进线
端,端子4—5为散热风机电源进线端,端子3—6为
接地保护线。
Open the output cabinet, remove the
protective cover. The control power terminal
is on the right bottom, the terminal 1-2
represent the input of the control power, the
terminal 4-5 represent power input of the
cooling fan, the terminal 3-6 represent the
protective earthing.
Cooling fan
AC220V

Page 13
4. 逆变器电气连接 Inverter Electrical Connection

4、逆变器通讯控制接线
Communication cable wiring

打开输出柜,拆下防护罩挡板,在输出柜的右侧下方有
控制接线端子,端子1-2为RS485接线端口。
Open the output cabinet, remove the protective 1positive
cover. The control terminal is on the right 2negative
bottom, the terminal 1-2 represent wiring ports
of RS485.

注: RS485通讯电缆请务必采用双绞线,以免通讯信
号造成干扰 !
Note: The communication cables of RS485
must be twisted-pair wire, which avoids the
signal interference.

Page 14
5.逆变器的运行操作 Operating the inverter

1、确认控制正常
Confirm the control power
打开输出柜挡板,确认图中所示位置接线紧
固,有AC220V电压输入。
Open the protective cover of the
output cabinet, confirm the
connection shown in the figure is
fastened and has AC220V power.
Input:
AC220V

Page 15
5.逆变器的运行操作 Operating the inverter

2、控制电源开关闭合
Confirm the control power
switch

在确保控制电压(AC220V)正常情况下,闭
合控制电源开关,如图所示(开关键往上)。
Make sure the control voltage
(AC220V) is acceptable, then close the
control power switch, shown in the
picture.

Make sure
8A,8AB are
switched off

Page 16
5.逆变器的运行操作 Operating the inverter

3、闭合断路器
Switch off breakers
闭合
72B1
在确认直流输入端接线正确,连接可靠,电压正常 等接线
后装好外护罩的情况下,闭合72B1到72B16接线 回路
Switch
回路,如图所示(开关闭合应在ON位置)。 off
Confirm that the DC input wiring is correct, 72B1-
72B16
the connection is reliable, the voltage is
normal and the outside cover is installed.
Then switch off the 72B1 to the 72B16, as
shown in the picture (the switch should be in
the on position). 确认进线
电缆口封
堵完好
Confirm
the inlet
cable is
blocked
in good
condition

Page 17
5.逆变器的运行操作 Operating the inverter

4、点击启动
Click the start button

如右图所示,直流DC、交流AC指示灯亮,无其
它指示灯亮,显示屏正常无故障显示,交直流
电压显示正常后,点击屏上主界面状态栏,点 启动
击“启动/停止” 。 start/停
As shown in the image on the right, 止stop
confirm that DC and AC indicator lights
are on, no other indicator lights are on,
the screen is normal and no fault is
displayed, AC and DC voltages are right; 交直流指示
灯AC/DC
then click on the main interface status indicator
bar on the screen, click "Start/Stop". light

Page 18
5.逆变器的运行操作 Operating the inverter

5、按启动/停止键
Press the start/stop button

长按启动键二到三秒,之后输出柜中交流断路器发出声响, 启动start/
逆变器启动完成,反之长按停止键二到三秒机器停止。 停止stop
Press the “start” for 2 or 3 seconds, after the AC
circuit breaker in the output cabinet makes a
sound, the inverter starts completely. Instead,
press the “stop” for 2 or 3 seconds to stop the
inverter.

警告 WARNING
请严格按照以上顺序操作,不得违规操作。如按照上一页步
骤操作,如果不能正常开机运行,为保证您的安全,断开电
源,不要做任何操作,并与我们联系,谢谢!
Please strictly follow the above steps to operate the
inverter, do not violate the operation. If you follow
the above steps and the inverter do not response,
please disconnect the power supply to ensure your
safe, do not try any other operate and contact us,
thank you!
Page 19
5.逆变器的运行操作 Operating the inverter

6.紧急停止
Emergency stop

可在紧急的情况下停止逆变器运行,按图中红框
标出的按钮即可。
Stop the inverter from running in an
emergency situation by pressing the
button marked in the Red box in the right
top figure.

复位时急停开关按照上箭头方向旋转,急停开关
弹起复位,所有的直流(72B1到72B16)开关应
复位一下,显示屏后的复位开关(RESET)向下按
下复位。显示屏上显示刷新,所有故障清除后,
运行逆变器。
When reset emergency stop button, rotate
the button according to the flow arrows,
then the button is bounce up. All the DC
breakers (72B1-72B16) need to be reset,
and the reset button at back side of the
screen should be pressed. Later the fault
disappears, start inverter again.
Page 20
6. 逆变器的运行状态信息 Inverter Running Status Information

1、工作状态
Running

LCD灯亮的情况:逆变器运行
LCD light on: inverter running

RUN------灯亮
RUN------light on

DC ON------灯亮
DC ON-----light on

AC ON------灯亮
AC ON-----light on

剩余灯都不亮。
Other lights are off

如图所示。
As shown in the right picture.

Page 21
6. 逆变器的运行状态信息 Inverter Running Status Information

2、逆变器待机状态
Standby

逆变器待机:逆变器的功率在待机功率以下
和太阳光照不足的情况下,逆变柜处于待机
状态,只有超过开机功率和太阳光照足的情
况下,逆变器会恢复为正常运行状态。待机
LCD灯在待机状态时绿灯亮,如图所示。
Inverter standby: if inverter running
power is under standby power or
solar energy is insufficient, the
inverter is in standby state.
The standby LCD light is green when
the inverter is on standby status, as
shown in the figure.

Page 22
6. 逆变器的运行状态信息 Inverter Running Status Information

3.故障信息查看
Fault information view

当显示屏中INV FAULT灯亮时,代表逆变
器有故障,按照下面步骤排查故障。
When the INV FAULT light is on, the
inverter is facing fault. Please
troubleshoot any fault by following
steps.
It indicate problem with the inverter ,
follow there steps to troubleshoot.
①点击LCD显示屏“信息”栏(此“信息”是闪
烁的),以此进入故障显示界面,如图所示
的红框内。
①Click on the bar on the LCD
(blinking), enter the fault information
interface, shown in the Red frame of
the picture.

Page 23
6. 逆变器的运行状态信息 Inverter Running Status Information

4.故障信息代码示意
Fault code examples
②如图所示,红框标出的故障显示为<电网异常>,即电网欠
电压,以此可根据提供的信息采取相应的解决办法。
②As shown in the figure, the fault information
marked by the red frame is shown as <grid
abnormal>. This information can lead to a related
solution.
代码指示意为:
Fault code examples:
UA+++ ----------------警告 warning
UF+++ ----------------故障 fault
U%0++ ----------------整流电路故障 rectifier circuit
U%1++ ----------------直流电路故障 DC circuit
U%2++ ----------------逆变电路故障 Inverter Circuit
U%3++ ----------------控制电路故障 control circuit
U%4++ ----------------旁路系统故障 by-pass system
U%5++ ----------------警告 warning
U%+00 -U%+49 ---------重要故障 major fault
U%+50 -U%+99 ---------次要故障 minor fault
*)“+”代表0到9的任意数字 “+”Mean 0-9
*)“%”代表“A”或“F” “%”Mean
“A” or “F”

Page 24
7.定期检查维护注意事项 Considerations of Regular Check and
Maintenance

检查对象 检查点 Detail


序号 判断标准Judgment
Check
Number 周期 Criteria
object 检查项目 Check item 检查方法method
period
集装箱内部屋顶,连接螺栓。 无损坏无漏雨现象和腐蚀,链接螺
The top of the internal in 每月 目测.触碰 visual 栓紧固良好。No damage, no
(1)-1 container ,connecting monthly inspection, touch. leakage of rain ,corrosion,
bolt. tighten the bolts.
线缆无破损,接线端紧固良好,进
外部线缆和连接,进出电缆口, 出电缆口封堵良好,无小动物活动
电缆桥架。External 每月 目测.触碰visual 痕迹。 Cable
(1)-2 cables ,cable portal, cable monthly inspection, touch. not be damaged ,tighten the
bridge. bolts ,cable portal plugged.no
animal tracks.
运行时无异常声响、异味和不正常
外部检查 运行时噪音,振动和气味。逆
目测.嗅觉.触碰 振动。保持逆变器室地面干净整洁
Visual 变器室干净整洁。Running 每周
(1)-3 Inspection noise, vibrate and smell, weekly
visual inspection, running any abnormal sound,
smell, touch. peculiar smell, abnormal
the E-room clean and tidy .
vibration. Clean and tidy .
集装箱滤网,逆变器滤网
每月 目测.触碰visual 空气进气和出气无阻塞。滤网清洁
(1)-4 Container filter screen,
monthly inspection, touch. 无阻塞。Filter screen no dust .
inverter filter screen.

观察集装箱内温度情况 无过热情
观察集装箱内温度情况 ,散 况,扇热风机正常运行空气流通无
每月 目测. visual
(1)-5 热风机。Container
monthly inspection
阻塞。Container temperature
temperature ,cooling fan normal and cooling fan
running normal.
Page 25
7.定期检查维护注意事项 Considerations of Regular Check and
Maintenance

1、逆变器过滤网维护
Inverter filter maintenance

逆变器过滤网要定期清理,有破损要及时更换,
保持逆变器散热顺畅。机器运行应关闭所有逆变
器柜门,保持逆变器内部清洁。
Inverter filters should be cleaned
regularly, any filter with damage need be
replaced in time. The cabinet doors should
be kept closing when the inverter is
running.

Page 26
7.定期检查维护注意事项 Considerations of Regular Check and
Maintenance

2、单元电容检查
Capacitor unit inspection

逆变器电容要定期检查,查看是否有电容漏液,变形
等现象,如有破损应及时更换。(注意:拆开单元防
护罩检查时,一定要断开交直流电源开关,确认没有
交直流电后才可以进行检查)
Inverter capacitor units should be check
regularly to see if there is any capacitor
leakage liquid, deformation and other
phenomena. The capacitor unit should be
replaced if any damage has been found.
(note: Before removing the protective cover,
disconnect all power supplies first.)

Page 27
7.定期检查维护注意事项 Considerations of Regular Check and
Maintenance

3、逆变器室温湿度
Indoor temperature and humidity

查看逆变器室内温度应在-20~50℃,湿度应在 5~95%无凝,
如果过温或过湿应检查散热风机排风是否正常,查明原因排除故
障,湿度太大请先除湿后达到正常湿度方可运行逆变器。
The indoor temperature of container should be between
-20~50℃; while humidity of that should be between 5~
95%, without condensation problems. Over temperature
or humidity situation need to be solved by checking the
cooling fans and making them operating normally.
Restart the inverter after troubleshooting.

Page 28
7.定期检查维护注意事项 Considerations of Regular Check and
Maintenance

4、电缆进出线口封堵
Cable portal block off

逆变器室电缆进出线口在设备运行前必须进行
封堵,现场巡检时也要定期检查是否有脱落现
象,及时封堵。防止小动物进入机器内造成机
器损坏事故。
The inlet and outlet cable portal of the
inverter container must be block off
before the inverter running. Regular
check should be implemented to find
out any shedding which need to be
repaired in time.