Olympus NDT Products

Hardware and Software Available for


Your Application

info@rd-tech.com • www.rd-tech.com
Hardware

OmniScan, FOCUS, FOCUS LT,


TomoScan III, and QuickScan

info@rd-tech.com • www.rd-tech.com
Ultrasound Product Line
OmniScanMX
 Powerful, portable, field-rugged
 Battery-operated modular PA unit
QuickScan
 PC interface, 128 or more channels
 Reduced cost for industrial installations, rack-
mounted
TomoScan III
 PC interface
 12-bit system, for high speed, high PRF, high data-
rate applications; conventional or phased array
 Perfect for nuclear
FOCUS LT Phased Array System
 PC interface, high data rate transfer
 Up to 256 channels
 20 kHz PRF and 20 MHz bandwidth
Leader in Array Technology
Instrumentation Nomenclature

 Phased array units (FOCUS or QuickScan) are


defined as two numbers divided by a colon, e.g.,
32:128.
 This refers to an instrument with 32 multiplexed
pulsers and 128 individual channels.
 R/D Tech instruments are supplied in binary sizes,
e.g., 16:64, 16:128, 32:256, ….
 Instruments are custom-built for the application,
except OmniScan -> standard product.
 Typically have conventional channels as well for
additional scans.

Leader in Array Technology


Leader in Phased Array Technology

First system on site: 1993


More than 400 PA units sold
Improved technology
4th generation
Advanced PA technology
DDF-VFT-TRM
Now being discontinued and
replaced by FOCUS LT

Leader in Array Technology


FOCUS LT

•Replaces old
FOCUS
•“Smaller,
cheaper, faster”
•4 MB/s data
transfer
•Works on
TomoView

Leader in Array Technology


Industrial Product Line

 An economical
solution for
industrial
requirements, e.g.,
in-line inspections
on production plant.
 Rack-mounted.
 High PRF.
 Similar capabilities
to FOCUS, but less
QuickScan PA flexible.

Leader in Array Technology


Sizing Your Phased Array Instrument

 The power of instrument required depends on the


application.
 For example, if coverage is the key issue, then a
lot of elements are needed. However, it may only
be necessary to pulse 16 elements in a group, so a
16:256 may be adequate.
 If the application has limited access, but needs a
lot of steering, then an instrument with many
pulsers but relatively fewer elements, e.g., 32:64,
may be better.

Leader in Array Technology


OmniScan

info@rd-tech.com • www.rd-tech.com
OmniScan - Product Concept
Portable
Weight ~ 8.8 lbs or 4 kg (incl. test
module and one battery)
Size 8 in. × 11 in. × 4.5 in.
(20.3 cm x 27.9 cm x 11.4 cm)

Battery operation (from 6 to 8 hours)


1 or 2 batteries
Smart Li-Ion batteries
Replaceable without interruption

External/internal charger
Operating time > 3 h/battery
Charging time < 3 Leader
h/battery
in Array Technology
Omniscan product line - Built for the Field

 Splashproof and shockproof


 Large visible-everywhere
display
 Complete stand alone unit
(no computer connection, no
mouse, no keyboard)
 User-friendly interface
 One software, one system for
all technologies
 Probe Identification function

Leader in Array Technology


Omniscan product line - Specifications for PA
•16 active elements
•128 elements
•Up to 256 contexts
•Bandwidth: 0.75 to 18 MHz (-3
dB)
•0–10 µs in 2.5-ns increments
delay
•80 V pulser voltage-adjustable
pulse width
•DAC curve and TCG

Leader in Array Technology


OmniScan - Around the Equipment

USB ports
CompactFlash
slot
Probe
connectors
Microphone
input
Battery door
LAN
Headset output
Strap anchors
AC adaptor
input Serial link

Leader in Array Technology


OmniScan - Modular Concept
Modular/multitechnology unit

Leader in Array Technology


OmniScan - Software Concept
• Function keys and knob
interface for field used
• Data on RDTIFF file
exportable and compatible
with
- TomoView™
- MultiView™
• E-Z View™ for adequate
viewing and control in
operation conditions

Leader in Array Technology


OmniScan - Software

 Single-operator system (reduces costs)


 Mouse- and keyboard- compatible
 Dedicated for field use
 Flaw detector interface (easy transition from
manual to semi-automated)
 Remote console for easy operation with
only one operator
 Files compatible with TomoView.

Leader in Array Technology


OmniScan - Views
Channel name  X: 0  Y: 0

x1 pos x2 pos
End Y

y1 pos

y2 pos
Envelope
Zoom Y

Scale Y

Gate0

Gate1 Gate2

DAC

Begin Y

End X
Begin X

Scale X

Zoom X

A-scan B-scan C-scan

Sectorial-scan

And many combination displays.


Leader in Array Technology
New MultiChannel Software

New multichannel software allows multi-angle or multi-


display inspections simultaneously.
Good for weld code inspections or multi-information scans.
Can run eight channels, but can only display three at a time.

Leader in Array Technology


Manual OmniScan

Manual version of
OmniScan:
•No encoder
•No data collection
•Imaging only
•Can calibrate fully
•Really designed
for manual codes,
e.g. AWS
•Lower cost
Leader in Array Technology
TomoView Software

Phased array software, which can be


set-up or tailored to your needs

info@rd-tech.com • www.rd-tech.com
TomoView
PC-based UT software
 Real-time, multichannel,
angle-corrected top, side,
and front views
 Pulse-echo and TOFD
functions
 Logarithmic and linear
12-bit data
 RF, compressed, and C-scan
data
 Weld overlays
 User-defined screen and
report layouts
 Handles GB-size data files
 Online and offline modes

Leader in Array Technology


TomoView

 Can prepare Focal Laws on TomoView and


transport to OmniScan
 Can transport OmniScan data files to
TomoView for advanced analysis
 TomoView more difficult to use, but major
advantages, e.g. displays and data merging
 TomoView 2.7 Lite good for OmniScan
applications.

Leader in Array Technology


Overview – Phased-Array Features

Corrected S-scan view

Uncorrected S-scan View

Leader in Array Technology


Merging of data

 Raw UT data generated by different focal laws


(angles, focusing depths) can be merged off-line
to generate new UT data
 Merged data contain maximum amplitude of the
different focal laws
 Merged data can be treated as regular data, and
visualized as VC Top (C-scan), Side (B-scan), and
End (D-scan) Views

Leader in Array Technology


New TomoView 2.4 Multiviews

Leader in Array Technology