SpectralWaveTM V-Node

CID Setup Menu


Explanation

V-Node CID 1
3-Node Setup System Configuration

192.168.1.1
LAN Slot 13
192.168.1.10 User
IP=192.168.1.11 192.168.2.1

GW=192.168.1.1

Slot 12 NW
192.168.2.2

LAN
192.168.3.1
192.168.3.1
Slot 13 NW
User
192.168.4.1

Slot 13 NW
192.168.4.2

LAN
192.168.5.1
192.168.5.1

V-Node CID 2
Node 001

Green Slot
indicated
unit not mounted

Pink Slot
indicated
unit mounted
without
registration
with MCP

V-Node CID 3
Communication Setup

Main Menu- Communication


Sub-Men
IP Parameter Setup
Physical layer setup
DCC Link Layer setup
Route Table

V-Node CID 4
DCC Setup (1)

Node 001 DCC Setup Display


Slot13 DCC1 Used

V-Node CID 5
DCC Setup (2)

DCC Pass Through Setting required only when other vendors NMS data intend to pass
through V-Node

Slot13 DCC1Port
Set to Enable

V-Node CID 6
DCC Setup (3)

Presently only slot 13


DCC port is activated and
marked with green

Routing Table
Indicated that network
possible to be reached
from this C-Node

V-Node CID 7
Database Upload/Download

Database Upload Database Download

1. It is required to upload the V-Node configuration data and save it regularly if NE configuration
data changed.

2. But it is not required to download data to NE unless necessary. The backup NE data is stored
in flash memory build inside MCP unit and two CS units. The two CS database is used as
master controller for auto restoration.

3. Therefore only the 3 units are all damages then download to NE from NMS or PC is required.

V-Node CID 8
Database Upload/Download Menu

Main Menu- File


Sub-Menu 1. Database Upload/Download
2. Close

Select all items Refer to


or partially items previous slide

Folder selection

V-Node CID 9
Configuration

Main Menu- Configuration


Sub-Men
Setup NE -- Initial Setup Navigation
Set NE Attribute
Packet Protection Configuration
Timing Source Configuration
Timing Source Attribute
Set 2M EXT Clock Output
MSP Group Configuration
MSP Configuration
Cross Connect Configuration
Port Configuration
Port Enable
Set Trace Message
Set HKA/HKC
Order wire and user CH configuration
Adjust NE Time
Laser management

V-Node CID 10
Setup NE
For initial NE setup follow the flow chart for the basic setup
1. Setup - NE Attribute
2. Setup - Physical Slot Configuration
3. Setup - Timing Source Configuration
4. Setup - Set Timing Source
5. Setup - Set Timing Source Attribute
6. Setup - Set Others

Default Setting

NE Name Setting

NE location Setting

V-Node CID 11
Setup Physical Slot Configuration Menu

1. Unit identification

2. Unit Selection

3. Select work normally

Step 1. Click the slot to be


registered

Press Install

Pink Slot indicated unit mounted without registration with MCP


Green Slot indicated unit not mounted

V-Node CID 12
Setup Timing Source Configuration Menu

V-Node CID 13
Setup Timing Source Menu

V-Node CID 14
Setup Timing Source Attribute Menu

V-Node CID 15
Setup Others Menu

V-Node CID 16
Packet Protection Configuration – 1
Board Protection- Default protection status indication when both units are registered.

Another pair of unit protection


Is power unit, for this setup
Only one power unit is registered.

Default 1 plus 1 Unit protection


Status Indication

V-Node CID 17
Packet Protection Configuration – 2
TPS Protection

Step 1 Create TPS protection


refer to next slide

Step 2 Modify TPS protection


configuration if required
refer to next slide

Step 3 Delete the protection


group if TPS is no more
required.

V-Node CID 18
Create Board Wizard

Step 1 Select Board to be set

Step 2 Select Protect Mode

Step 3 Finish

Modify Board Wizard

Step 1 Add or Delete

Step 2 Select Protect Mode

Step 3 Finish

V-Node CID 19
Set 2M EXT CLK Output

Note -- For this NE, no EXT CLK module is installed in CS Unit

V-Node CID 20
MSP Group Configuration

V-Node CID 21
MSP Group Configuration

V-Node CID 22
Cross Connect Configuration

Method 1. Use graphic setup

Method 2. Use navigation table

V-Node CID 23
Cross Connect Configuration ---- Method 1. Graphic setup

1. Select Build to create or delete to delete

2. Select Single setup or Multi-entry setup

3. Broadcast for one way or two way

2. 1 plus 1 Primary for SNC/P and 1 plus Backup


is auto buildup.

V-Node CID 24
Cross Connect Configuration ---- Method 2. By navigation table

V-Node CID 25
Method 2. By navigation table (1)

V-Node CID 26
Method 2. By navigation table (2)

V-Node CID 27
Port Configuration 1

V-Node CID 28
Port Configuration 2

STM-16 Unit

V-Node CID 29
Port Configuration 2
CS Unit

V-Node CID 30
Port Configuration
E12 Unit

V-Node CID 31
Port Configuration 2

STM-1/4 Unit

V-Node CID 32
Port Configuration 2

MCP Unit

V-Node CID 33
Port Enable - 1

STM-16 Unit

V-Node CID 34
Port Enable - 2

STM-1/4 Unit

V-Node CID 35
Port Enable - 3

E12 Unit

V-Node CID 36
Set Trace Message

STM-16 Unit

V-Node CID 37
Set Trace Message

STM-4/1Unit

V-Node CID 38
Set Trace Message

For E12 Unit

V-Node CID 39
Set HKA/HKC

HKA Interface

V-Node CID 40
Set HKA/HKC

HKC Interface

V-Node CID 41
Order wire and user CH configuration –Order wire attribute

V-Node CID 42
Order wire and user CH configuration –Order wire channel

V-Node CID 43
Order wire and user CH configuration –User channel

V-Node CID 44
Adjust NE Time

V-Node CID 45
Laser management -- Available for STM-1/4/16

Attribute setting

V-Node CID 46
Laser management -- Available for STM-1/4/16

Manual Open

V-Node CID 47
Alarm

Main Menu- Alarm


Sub-Men
Current Alarm
History Alarm
Actual Alarm
Alarm Attribute Setup
Event View
Set HKA/HKC Name

V-Node CID 48
Current Alarm/History Alarm/Actual Alarm

V-Node CID 49
Alarm Attribute -- 1

V-Node CID 50
Alarm Attribute -- 2

V-Node CID 51
Alarm Attribute -- 3

V-Node CID 52
Event View

V-Node CID 53
Set HKA and HKC Name

V-Node CID 54
Performance

Main Menu- Performance


Sub-Men
Current PM
History PM
PM Counter Reset
PM Item Setup
PM Attribute Setup

V-Node CID 55
Current PM

V-Node CID 56
PM Counter Reset

V-Node CID 57
PM Attribute –1 STM-1 Case

V-Node CID 58
PM Attribute –2 100BT Case

V-Node CID 59
PM Attribute Setup

V-Node CID 60
Maintenance

Main Menu- Maintenance


Sub-Men
Loop Back control
Equipment Reset
Equipment Initialization
Erase NE History Data
Set History Data save Mode
Upgrade F/W and FPGA

V-Node CID 61
Loop Back control

V-Node CID 62
Equipment Reset

V-Node CID 63
Equipment Initialization

Erase NE History Data

V-Node CID 64
Set History Data save Mode

V-Node CID 65
Upgrade F/W and FPGA

V-Node CID 66
Security

Main Menu- Security


Sub-Men
Operation Log
User Management

V-Node CID 67
Operation Log

V-Node CID 68
User Management

V-Node CID 69
LAN Interface

Main Menu- LAN Interface


Sub-Men
Ethernet Port Configuration
Layer 2 Configuration
Encapsulation and LCAS Configuration
Bandwidth Configuration

V-Node CID 70
Ethernet Port LAN Port Configuration

V-Node CID 71
Ethernet Port WAN Port Configuration

V-Node CID 72
Layer 2 Configuration --- 1a

Bridge -- General

V-Node CID 73
Layer 2 Configuration --- 1b

Bridge – Delay Parameters Setting

V-Node CID 74
Layer 2 Configuration --- 1c

Bridge – Queue Parameters Setting

V-Node CID 75
Layer 2 Configuration --- 1d

Bridge – Monitor Parameters Setting

V-Node CID 76
Layer 2 Configuration --- 1e

Bridge – VLAN Mode Setting

V-Node CID 77
Layer 2 Configuration --- 2

V-Node CID 78
Layer 2 Configuration --- 3

V-Node CID 79
Layer 2 Configuration --- 4

V-Node CID 80
Layer 2 Configuration --- 5

V-Node CID 81
Layer 2 Configuration --- 6

V-Node CID 82
Encapsulation and LCAS Configuration

V-Node CID 83
Bandwidth Configuration--- 1

Double Click to pop up window


As next slide indicated

V-Node CID 84
Bandwidth Configuration--- 2

V-Node CID 85
Ethernet Port Cross Connect Configuration 1

#01-AU1

V-Node CID 86
Ethernet Port Cross Connect Configuration 2

#02-AU1

V-Node CID 87
Ethernet Port Cross Connect Configuration 3

Each FE Unit has 2 AU Port for


Cross-connect

V-Node CID 88