NAIK ENVIRO

OPERATION & MAINTANANCE


MANUAL FOR PACKAGE
SEWAGE TREATMENT PLANT
(STP)
1.5 mld, banganga.
Designed , Manufactured, Installed ,
Tested and Commissioned
by

NAIK ENVIRONMENTAL ENGINEERS PVT LTD


Address : A-686, Naikenviro House, TTC Industrial Area,
Pawan, Navi Mumbai- 400705. Tel: 022-27780811/2154
email : naikenviro@gmail.com Website: www.naikenviro.com
Patent No. 234990
PATENT CERTIFICATE
Project specifications
Objective of Work:
To treat and reuse the waste water for purpose like gardening, toilet flushing, car washing,
road & sewer cleaning to reduce the demand of fresh water in the city area.

Scope of the work:


•To design STP of 3 MLD capacity in two symmetrical modules of 1.5 MLD each.
•To construct one module of 1.5 MLD.
•To carry out O &M of 1.5 MLD STP for 15 years.

Automation & Control System


•Micrologix 1400 Programmable Controllers (SCADA) to control all pumps, valves,
switches & probes etc.
•Programmable Logic Control System.
•Online Flow measuring arrangements like DO meter, Temperature meter, pH & Flow meter.

Space Requirement:
Space given for Construction of two 1.5 MLD STP : 1274m2
Footprint used for Construction of one unit of 1.5 MLD: 225 m2 (75% space saved)

Energy Consumption:
Power Consumption will be less than or equal to 1849 units/day (inclusive of all the pumps,
illumination, Ozonation system)
PRODUCT INFORMATION
•Cuts Wastewater treatment costs by using the intensified package concept.
•Drastically reduces space requirements.
•Runs with a very low power input.
•Produces a sparkling, clear treated effluent free from any trace of odour.

NAIKENVIRO
THE OPERATING PRINCIPLE OF STP
3
2

4
1

Conceptually, the process is extremely simple: A small amount of microorganisms 1


converts a large mass of polluted water 2 into clean water 3. This process also produces a
co-product: A vastly reduced, compact solid biomass 4 (the excess microorganisms
produced by growth and multiplication of the original population of microorganisms).

NAIKENVIRO
FEATURES OF DESIGN
Treated effluent quality: Treated effluent meets the most stringent of standards (BOD: <10
ppm, TSS: <10 ppm).
Compact and elegant: The system is elegantly designed with particular emphasis on
compactness, aesthetics and ergonomics.
Custom designed Geometry: Geometry of the unit has been tailored to suit the site
geometry. The system requires far less space than that earmarked for the plant.
Odour free environment: The system design ensures an odour free environment unlike
competing systems.
Low process power input: Less than 30% of that for a conventional activated sludge
systems.
Corrosion free materials: The plant is manufactured from mild steel plates and structural
with resin epoxy coating on all surfaces for superior protection against corrosion.
Minimal moving parts: Geared motors, pumps and support bearings for the RMBR
constitute the moving parts requiring lubrication and servicing. The easy
accessibility of these makes maintenance very convenient.
Modular design: As the design is modular, expandability of the plant is convenient.
Installation: Installation is very easy as the plant is entirely prefabricated and is merely to
be mounted at the site.

NAIKENVIRO
Dismantling and relocation: The entire plant can be conveniently shifted to a new
location in future.
Automated operation: The plant is designed for automated operation therefore
manpower operation is minimal.
Technology: The entire system can be remotely operated through a SCADA system and
this is the first such Sewage Treatment Plant in India.
Complete drying of sludge: Wedge-wire Stainless Steel trolleys with heating coils
ensures complete drying of sludge, destruction of pathogens and deodorization,
and drastic reduction in volume of sludge for disposal
Cleaner environment: The fully enclosed design ensures a clean environment unlike
competing systems.

NAIKENVIRO
NAIKENVIRO

DESIGN CRITERIA

RAW TREATED

• PH 6.9 Mg/l • PH 6.5-9.0

• TSS 840 Mg/L • TSS < 10 Mg/L

• COD 630 Mg/L • DO < 4 Mg/L

• BOD 272 Mg/L • BOD < 5 Mg/L

• O&G Below Detection Level • Nitrogen as Ammonia < 5 Mg/L

• DO Below Detection Level • Fecal Coli Forms < 200 Nos./100 Ml

• FREE AMONIA 21 Mg/L • Color Colorless

• CHLORIDES 132 Mg/L • Odor Odorless

• TEMPERATURE 29 C
PROCESS FLOW DIAGRAM
Raw waste Settling Tank
Screen water pump

Flocculation Channel

RMBR
Sludge Dewatering System

Sludge

Meters:
1] Flow meter
2] pH meter
3] Temperature meter Activated Carbon Filter
4] DO meter
Treated Treated
Water Water
Tank Tank

Ozone
Pressure Sand Filter
Dosing Filter Feed Tank
System

Backwash/Rinse
NAIKENVIRO
PLANT LAYOUT
3-D DRAWING OF 1.5 MLD STP

RAW
RMBR- SEWAGE
1,2,3 TANK

SETTLING
TANK- 1,2,3
BEFORE AFTER
Plant parts

NAIKENVIRO
1. Raw sewage tank- It collects the incoming sewage.

2. Raw sewage pumps- These can be submersible/horizontal/ centrifugal in arrangement


and are used to pump the water from Raw sewage tank to the RMBR after primary
treatment i.e., removal of floatable plastics or solids using different types of screens.

3. RMBR- The RMBR brings about an intimate contact between the substrate in the
wastewater and the active micro-organisms, in the presence of air. Here, organic matter in
the wastewater comes into contact with a very large area of a biofilm residing on
polypropylene media placed in the drum.

4. RMBR media- The media is of material polypropylene which is typically 12 cm in


diameter, available surface area is greater thus larger bacterial population for the digestive
process is available. The media is forty per cent (40%) immersed in wastewater. As the
tank rotates, bacteria present in the wastewater, adhere to that plastic media as a film of
slime.

5. RMBR tank- The tank provides the environment in which the digestion process occurs. It
constricts the path of the wastewater stream to allow maximum exposure of organic waste
in the water stream with the media.

NAIKENVIRO
6. Settling Tank- Insoluble’s are separated from the water. The settler is based on the widely
used principle of shallow depth sedimentation. After the retention time of 4hrs the Sludge
settles into the hopper under the effect of gravity.

7. Filter Feed Sump- Clarified water from settler is collected in a filter feed sump, from where
it is pumped for filter treatment. Here, the water is retained for 10 min for aeration.

8. Filtration unit- The pressure sand filter contains specially designed bed of graded quartz
sand which removes residual colloids while the activated carbon column removes the
residual dissolved trace organic compounds thereby rendering water free of organic
contamination. The activated carbon also removes excess chlorine residuals resulting from
hypochlorite dosing.

9. Valves- Filter , Backwash , Rinse , Recirculation , Closed.

10. Rotameter- The flow of the incoming treated water is measured with the help of
Rotameter.

11.Treated water tank- The water after primary, secondary as well tertiary treatment render
into the treated water tank from where is supplied for different purposes like gardening,
toilet flushing etc.

NAIKENVIRO
NAIKENVIRO

STANDARD
OPERATING PROCEDURE
1. Raw wastewater passes through a bar screen, which separates floatable solids from the
incoming tank, and is collected in a Raw Sewage tank and pumped at a steady rate into
the ECO-BIO-PACK.

2. The wastewater flows through the rotating media bioreactor where organic matter in the
wastewater comes into intimate contact with a very large area of a rotating bio-film
residing on synthetic media.

3. Aeration is achieved by rapid surface renewal of thin films of wastewater. As the film
grows in thickness it sloughs off and a new film takes its place. This is a far superior and
energy efficient system compared with bubbled aeration processes.

4. The effluent from RMBR flows through a settler in which sloughed biological solids
settle to the bottom of the tank in quiescent conditions while clarified water flows out on
a continuous basis.

5. Settled sludge is discharged on a periodic basis into a suspended bag sludge dewatering
system. Dewatered humus is an excellent soil conditioner and is therefore a valuable by-
product of the system.
8. Clear water is then polished by pumping it through a Dual Media Filter containing
Activated Carbon.

9. Filtered water is disinfected using an Ozone Dosing System before utilization for
toilet flushing or gardening or any other designated use subject to our acceptance.

10. A bypass Orifice type Rotameter is provided to measure the flow rate.

11. The entire operation is extremely simple and the system once stabilized, can be left to
itself with very little human intervention. A Control panel takes care of the operation
of the plant.

NAIKENVIRO
Unit operation

NAIKENVIRO
SCREEN NAIKENVIRO
Major unit operations in STP
RMBR
1. Raw Sewage Pumping Arrangement

2. Inlet Chamber Unit

3. Screen Chamber Unit

4. Secondary & Tertiary Treatment Unit

5. Disinfection Unit

SETTLING TANK
6. Sludge Collection & Treatment Unit
FILTERATION UNIT
7. Treated Water Tanks

8. Automation & Control System

CONTROL PANEL

OZONATER

LABORATORY/ CONTROL ROOM


SCREENING
The function of the bar screen is to prevent entry of solid particles/ articles above a certain
size; such as plastic cups, paper dishes, polythene bags into the STP. (If these items are
allowed to enter the STP, they clog and damage the STP pumps, and cause stoppage of the
plant.)

1 Inlet pipe for the STP


2 Debris (plastic bags, paper cups, paper dishes, etc.)
gets trapped here.
3 Muck (sediment in sewage)accumulates and
blocks the grill (if not cleaned regularly)

4 Grill. Must be cleaned regularly to avoid build-up


of debris (2) and muck (3).

5 Screened sewage. If the screen (4) is maintained


well, this would be free of any large articles.
6 Outlet pipe (goes to the Equalization Tank)

7 Platform. The STP operator stands here to take out


the debris (2).
RAW SEWAGE PUMPING
If we use gravity to move the sewage through the units of STP, the units would have to be placed
progressively deeper below the ground level. To avoid deep excavations, a pumping stage is introduced
to lift sewage to the next unit in the STP.
Two raw sewage pumps are provided with level control system and provision for pump selector and
auto/manual operating mode.
1 There are two identical pumps. Controls ensure that only
one pump can run at a time.
2 Both pumps have independent suction pipes. The inlet
pipes extend almost to the
bottom of the tank, and must not have foot-valves.
3 The delivery pipes from both pumps are combined in a T-
shaped header. A delivery pipe takes sewage from this
header to the RMBR tank.
4 The bypass pipeline returns the excess sewage back to the
tank
Valves fitted on all three pipelines serve different purposes:
5 The valve on the bypass line is adjusted to “waste” the
excess capacity of the working pump. The delivery
pipeline (3) always carries sewage at the designed flow
rate.
The valve on the delivery pipe is closed off when the
corresponding pump is removed for repairs. This prevents
sewage delivered by the other pump from coming out.
ROTATING MEDIA BIO-REACTOR
In rotating media bioreactor degradation of organic matter present in raw sewage takes
place. RMBR rotates at speed of 2 – 3 rpm with the help of gear drive provided.
40% of RMBR is submerged into the wastewater at any instant and 60% is open to air.
Raw sewage is discharged in to RMBR @ 62.5 cum/hr.

1 RMBR Drum. It is in continuous rotation at 2-3


1 rpm. While rotating it is 40% submerged in water
2 and 60% exposed to air. The microbial growth
takes place on its surface, inside it is fully packed
with media.
4
3 Inside the RMBR drum, is the polypropylene
2
5 media with a high surface area to support
maximum growth of beneficial micro-organisms.
3 RMBR tank receives sewage from raw sewage
tank and has a retention time of 30 mins where the
digestion by the biofilm takes place.
4 The RMBR is rotated with the help of a motor,
chain sprocket system.
5 The treated water from the RMBR tank then flows
to the Flocculation channel where alum dosing is
done and flocculation of the organic treated matter
takes place.

NAIKENVIRO
ALUM DOSING
• Alum dosing system is provided for floc formation and settling of biologically
treated sewage.
• Keep the brick alum at the at flocculation channel provided.
• Solids formed in RMBR are then settled and remove in settling tank.

NAIKENVIRO
SETTLING TANK
The purpose and function of the secondary clarifier is twofold:
 Allow settling of biomass solids in the Mixed Liquor (biomass slurry) coming out of the
RMBR tank, to the bottom of the clarifier.
 To thicken the settled biomass, in order to produce a thick underflow.

NAIKENVIRO
1 The sewage inlet pipe brings sewage from the flocculation tank.

2 The incoming sewage enters from the end of the inlet pipe and gently releases it in the settling tank,
without causing any disturbance or turbulence.

3 The sludge is only slightly heavier than water; so it takes time to sink. It slides down the steeply
sloped walls of the tank toward the centre of the bottom. (collects in hopper)

4 The bacterial flocs collect here in high concentration.

5 The sludge flows out under the effect of gravity to the sludge dewatering system

6 The clear water rises to the top of the tank.

7 The clarified water pipe takes the decanted water to the clarified water sump.

NAIKENVIRO
FILTER FEED PUMP
• Two filter feed pumps are provided in the filter feed sump with level controller and
auto/manual operation.
• Treated water from intermediate tank is discharged into the filter feed sump.
• Once the water level in filter feed sump reaches at pre-determined top level one of
pump starts automatically if auto operation is selected.
• This pumps steadily deliver the water at the top of pressure dual media filter
• Filter feed pumps are also used for backwashing of filter columns.

NAIKENVIRO
PRESSURE SAND FILTERATION

• FRP sand filter with multiport valve is


provided for pressure sand filtration.
• Keep the valve in normal filter mode
• Start the filter feed pump.
• Water is discharged at top of filter.
• Solid particle are trapped on sand and
clarified water from sand filter is
discharged to drain or used for gardening.
• Sand filter needed to be backwashed for
removing the trapped solids.

NAIKENVIRO
ACTIVATED CARBON COLUMN

• FRP activated filter with multiport valve is


provided.
• Keep the valve in normal filter mode
• Start the filter feed pump
• Water from sand filter is discharged at top of
carbon filter.
• Odour if any, other organic matter and excess hypo
from sand filter is adsorbed on the activated
carbon.
• Treated water from carbon column is discharged
into treated water storage tank.
• Carbon filter needed to be backwashed for
removing the organic matter trapped on it.

NAIKENVIRO
BACKWASH OF FILTER
• When pressure over comes to 2 kg/cm2 backwash should be needed.
• Stop the pump. Adjust the multiport valve in backwash mode.
• Start the pump.
• Backwash water is discharged to the raw sewage tank.
• Backwash should be performed for 5 to 10 minutes after every 8 hours operation.
• Once backwash is completed, stop the pump.
• Adjust the multiport valve in normal filter mode.
• Start the pump.

NAIKENVIRO
OZONATION OF TREATED water
• Ozone is injected into Treated Sewage Water with the help of ozonator provided.
• Ozone generated in Ozonater is injected at treated water tank.
• Ozonation of treated sewage ensure that minimum 2mg/L of Dissolved oxygen is
maintained

NAIKENVIRO
SLUDGE HANDLING
Biological treatment of wastewater perforce produces excess biological solids due to the growth and
multiplication of bacteria and other microorganisms in the system.
The excess biomass thus produced needs to be bled out of the system, and disposed off efficiently.
This is a FOUR-step process: sludge removal, storage, dewatering and disposal.

1 The stainless steel table allows splashing of water


without getting rusted.
2 The openings have a collar beneath, where the bags can
be clamped
3 The sludge pipeline brings sludge from the settling
tank.
4 The valves can be used to regulate the flow rate, and
also to turn off if there is no bag beneath.
5 The laminated poly bags capture the floc, but allow the
water to run.
6 The stainless steel collection tray collects the water
(and fine sediments)
7 The stainless steel grill supports the bags and allows
the water to fall through.
8 The collection pipe takes the filtrate back to the Raw
water tank.

NAIKENVIRO
NAIKENVIRO

LUBRICATION
• Use gear oil no.320 ( Castrol make) for RMBR gear drive
• Recommended oil change : once every three month
• RMBR bearing grease : once in every three month.

NAIKENVIRO
SCADA
•The operating system at site is SCADA, which stands for supervisory control and data
acquisition. It is an industrial control system where a computer system monitors and
controls the ongoing operation/process.
•The software gives various information's like details of pump operation, breakdown
details, energy consumption, treated water quality parameters, historical trends etc.

Main Screen NAIKENVIRO


SCADA –Home Screen NAIKENVIRO
Daily reports

NAIKENVIRO
Daily reports

NAIKENVIRO
Daily reports

NAIKENVIRO
Daily reports

NAIKENVIRO
TROUBLE SHOOTING
POSSIBLE FAULTS CAUSE REMEDIES

PUMP FAILS TO PRIME SOLID PARTICLE MAY GOT STUCK OPEN THE CASING AT BOTTOM
UP IN IMPELLOR AND REMOVE THE SOLID
PARTICLES
PUMP NOISY BEARING APPLY GREASE TO BEARINGS

RMBR BEARING NOISY IMPROPER LUBRICATION FREQUENTLY APPLY GREASE TO


BEARINGS
RMBR GEAR MOTOR HEATS UP LESS OIL LEVEL FILL UP WITH GEAR OIL 150
RMBR OVERFLOWS PUMPING RATE HIGH THAN ADJUST THE VALVE OF RAW
CAPACITY SEWAGE PUMP
SETTLING TANK EFFLUENT TURBID INSUFFICIENT SLUDGE REMOVAL FREQUENTLY PUMP THE SLUDGE
FROM SETTLING TANK FROM SETTLING TANK IN TO
TROLLEY
SLUDGE FLOATS ON TOP OF SAME AS ABOVE SAME AS ABOVE
INTERMEDIATE TANK
TREATED EFFLUENT FROM DUAL IN SUFFICIENT BACKWASH INCREASE THE BACKWASH
MEDIA FILTER COLUMN TURBID DURATION
ODOUR TO TREATED PUMPING RATE HIGH THUS NO CHECK THE FLOW RATE FLOW
WATER/PARAMETER REQUIRED DETENTION TIME FOR RATE . SHOULD BE <=62.5 CUM/HR.
NOT WITHIN LIMIT SEWAGE IN PLANT AVAILABLE MEASURE FLOW BY STOPWATCH
METHOD AT OUTLET OF
INTERMEDIATE SUMP
INSUFFICIENT CHLORINE DOSING INCREASE THE CHLORINE
PERCENTAGE IN CHLORINE
SOLUTION

NAIKENVIRO
METERING PUMP NOT FUNCTIONING FUSE BLOWN OUT REPLACE FUSE

Digital Flow meter shows erratic check as per causes and rectify.replace as per vendor
FM1 Chokage /flow meter fault
readings manual.

FM2 Digital Flow meter broken Accidental impact or load Replace .

If the ph reading of the incoming Alum added is in excess, the


pHM 1 Reduce the dose of alum in the process.
treated water is less than 6 water is acidic

If the ph reading of the incoming Alum added is insufficient, the Increase the dose of alum. Maintain the pH between
pHM 2
treated water is more than 9 water is alkaline 6-9.

Ozonater Ozone not coming Problem with electrodes Check & Rectify as per manual.
Dissolved Oxygen is less than
2mg/l Ozonater not working Check & Rectify as per manual.
DO M
Temperature is not monitered &
Check & Rectify as per manual.
TEMP M recorded Problem with Probe

Refer O&M manuals pump/gear motors/dosing pumps.


maintenance
A]BAR SCREEN

•Check and clean the bar screen at frequent intervals.


•Do not allow solids to overflow/ escape from the screen.
•Ensure no large gaps are formed due to corrosion of the screen.
•Replace corroded/ unserviceable bar screen immediately.

B] GREASE TRAP

•Check and clean trap at frequent intervals. Remove both settled solids (at bottom) and the
floating grease.
•Do not allow solids to get washed out of the trap.
•Do not allow oil and grease to escape the trap.
•Redesign the trap if solids and grease escape on a regular basis, despite good cleaning
practices.
D] PUMPS

•Pumps do not start 1) Check the power supply.


2) Check the float switch.
3) Check the water level for operating Float switch.

•Pump getting over-heated: 1) Pump running dry


2) Delivery line/ pump casing blocked remove the pump
and clean
3) check for proper supply of voltage.

•Pump give less discharge 1) Inlet of pump blocked, Remove and clean
2) Discharge head is beyond Pump capacity, select proper
pumps

•Pump is noisy: 1) Impellor clogged/ damaged.


2) Delivery flow too high.
3) Obstruction in delivery line.
E ] MOTOR

•Motor will not start: 1) Replace fuse


2) Check bearing and lubrication
3) Reduce load
4)Look for broken parts

•Motor runs & dies 1) Check for loose connections.


down:

•Motor does not come 1) Use higher voltage


to speed: 2) Look for cracks near the rings, New rotor is required.

•Motor gets hot/ 1) Decrease belt tension.


burns out: 2) Alignment of coupling faulty/ loose.
3) Move pulley closer to motor.

Noisy operation: 1) Remove interference.


2) Tighten holding bolts.
3) Check & correct bearing.

•Motor vibrates: 1) Realign.


2) Strengthen base.
3) Balance coupling/ bearings.
F] CHEMICALS:

•Prepare fresh solutions every day in the tank.


•Shelf life of over 2 months is not recommended, especially during summer.
•Store chemicals in a cool place.
•Study Material Safety Data Sheets of the chemicals and follow instructions.
•Periodically check available strength of chemicals by mock tests.
•Check and record concentration every day.

G] SLUDGE HANDLING

•Fresh sludge (not more than a day old), kept fully aerated and mixed (agitated), dewaters
easily in the filter press. Hence, sludge must not be stored in the holding tank for longer
durations.
•After every dewatering operation, the filter cloths must be thoroughly cleaned, so that
clogging in the pores of the woven polypropylene filter fabric is avoided.
•Periodic cleaning of filter cloth with Hypo solution will also prolong the life of cloth.
•When the filtration process becomes excessively slow, it is time to replace the filter cloth
with a fresh set.
SOME PRECAUTIONS TO BE TAKEN
•Never stop the RMBR even if there is no raw sewage inflow.

•Never quit the backwash operation provides necessary backwash.

•De-sludge at recommended frequencies.

•Always apply sufficient grease to RMBR bearings.

•Refer vendor manual for equipment maintenance.

•Before starting the pressure filters ensure that valve at outlet of filter is open.

•Ensure proper lubrication for all equipment.

•Backup power to run the entire STP in case the mains electricity line fails.

•Design and engineer the STP to be operator friendly.

•Design and engineer the STP for the operator’s safety, health and hygiene.

•Adequate illumination in STP if in a room, or basement.

•Adequate exhaust and ventilation system to be provided for operator comfort, health and hygiene.
NAIKENVIRO
•Provide safe and comfortable access to all units in STP for monitoring, operation, and
maintenance.

•Prepare and maintain a Standard Operating Procedure for the STP and train all operators to
follow those procedures.

•Prepare and maintain a mechanical checklist for routine preventive maintenance.

•Prepare and maintain a History Sheet for critical equipment in the STP.

•Provide a Water meter at the outlet of the ACF to monitor average daily throughput of the
STP.