Sei sulla pagina 1di 39

SIEMENS Adaptors Explained

-Part 2
MPI,PPI,RS232,RS485,PROFIBUS

1
6XV1-830-0EH10/6XV1840-2AH10/6XV1830-
3EH10 Profibus cable

it's 100M/lot and the weight is about 9kg/100m 2


COMMUNICATION PROCESSOR CP 5512 PC
CARD (CARDBUS, 32 BITS)
6GK1551-2AA00

3
FOR CONNECTION OF A PG OR NOTEBOOK TO PROFIBUS OR MPI
Technical Data

4
Technical Data

5
Technical Data

6
Technical Data

7
Technical Data

8
Technical Data

9
CP5512: Communication Card for Laptop

US$365.00-$730.00

Correspond to Siemens 6GK1551-2AA00


10
CP5512: Communication Card for Laptop
• SIMATIC NET communication card for laptop, correspond to Siemens 6GK1551-
2AA00,optoelectronic isolated, anti-lightning and surging, suitable for laptop PCMCIA 32bit
CardBus slot, is used to achieve PROFIBUS/MPI/PPI/FWL communication connection between PC
and SIMATIC, communication speed is 9.6Kbps~12Mbps.After switched over by the transition
card, it can be used for desk computer and secondary generation ExpressCard slot laptop.CP5512
+(PCI->PCMCIA) transition card, then can be used for desk computer; CP5512 + (PCMCIA(II)-
>PCMCIA)transition card, then can be used for secondary generation ExpressCard slot laptop.

11
Introduction:
• CP5512 is the isolated PROFIBUS/MPI/PPI/FWL communication card
specially for laptop, use iCoupler isolators eliminate opto-coupler
limitations instead of Photoelectric isolation, with small dimension, wide
temperature range, and have anti-lightning and surging protective circuit
and Overcurrent protection with restoration function on the RS485
interface, all use industrial IC in order to apply to wider temperature range,
is used to achieve PROFIBUS/MPI/PPI/FWL communication connection
between laptop and SIMATIC.
CP5512 insert laptop PCMCIA slot from outside. Its function and Features is
the same as Siemens original CP5512(Siemens part nr 6GK1551-2AA00
),and have the following new characters.

1. Card and RS485 adapter integrative design, small dimension, use


conveniently and have anti-lightning and surging protective circuit on the
RS485 interface.

12
Introduction:
2. Support hot plug, you can plug or unplug the card when the laptop is running. And card and
adapter is integrated, so it’s not like original CP5512 which exist the hidden trouble that destroy
the card when plug or unplug the card from the adapter with current.

3. Support common Express to PCMCIA transition card. You can use it on the Express slot laptop.

4. Support common PCI to PCMCIA transition card. You can use it on the desk computer and the
function is the same as Siemens original CP5611 and CP5611 A2.

13
CP5512: Communication Card for Laptop
Communication service:
PROFIBUS-DP master station class 1 and 2
PROFIBUS-DP slave with SOFTNET-DP slave
MPI/PPI/FWL communication
S7 communication with SOFTNET-S7
S5-compatible communication (SEND/RECEIVE based on the FDL interface) with SOFTNET-DP or
SOFTNET-S7

CP5512 can be used with:


STEP7 V5.2
SOFTNET-S7 V6.1
SOFTNET-DP, SOFTNET-DP slave from V6.1
STEP 7-Micro/WIN from V3.2 SP4
ProTool®, ProTool/Pro® V6.0 SP2
NCM PC from V5.2
SIMATIC PDM V5.2 SP1
14
CP5512: Communication Card for Laptop
Technical Specification:
Transmission rate: 9.6Kbps~12Mbps,the corresponding largest communication
distance accord with PROFIBUS standard.
Interface: connect PROFIBUS/MPI/PPI, isolated 9 pin Sub-D connector.
Isolated voltage:1000VDC
Interface protection: have anti-lightning and surging protection(Ipp=100A
10/700us,4KV) on the RS485 interface.ITU-TK20/21,VDE 0433 standard. ±15KV
ESD protection. Overcurrent protection with restoration function:RS485 port
can withstand up to 60V voltage caused by continuous over-current.
Standard working voltage:3.3 VDC
power:1.0W
working temperature:-20~+75℃
Size:length* width * height(mm):130×54×5(DB9F plug height:22mm)
weight:70g

15
CP5512: Communication Card for Laptop
Support hardware of CP5512:
It’s different from PC Adapter and PC Adapter USB, CP5512 supports much more
hardwares,such as Siemens S7-200/300/400PLC, PPI/MPI/PROFIBUS interface of
touch panel, EM277,ET20 and other hardwares with PROFIBUS/MPI/PPI/FWL
interface.
It need PROFIBUS cable or MPI cable(Siemens part no. 6ES7 901-0BF00-0AA0)
when CP5512 communicates with fieldbus devices.

16
SETUP CONNECTION

17
CP5512: Communication Card for Laptop

18
Pin assignment

19
CP5512 Express card suitable for laptop
Express card slot

US$475.00 -$1,000.00 CP5512EXP

20
Introduction:
• Nowadays the laptops have eliminated the PCMCIA slot, but adopt the
ExpressCard slot. So we especially develop the CP5512 EXPRESS for
ExpressCard laptop.

• ExpressCard CP5512,it’s suitable for Laptop ExpressCard slot, is used to


achieve PROFIBUS/MPI/PPI/FWL communication between PC and SIMATIC
Net. Communication speed is 9.6Kbps--12Mbps.It can be also used for
desktop computer after the conversion card.

21
Introduction:
• Not include the MPI extension cable, for MPI cable, please click this link to
get: http://www.bestincn.com/MPI-cable-Cable-between-S7-200-300-PLC-
and-Siemens-touch-panel_p282.html

• The function of our CP5512 EXPRESS is the totally same as Siemens original
CP5512 except they use on different laptop interfaces. It's the isolated
PROFIBUS/MPI/PPI/FWL communication card specially for laptop, use
iCoupler Magnetic Coupling isolators to replace the opto-coupler, with
small dimension, wide temperature range, and have anti-lightning and
surging protective circuit and resumption of Overcurrent protection circuit
on the RS485 interface, all use industrial IC in order to apply to wider
temperature range, is used to achieve PROFIBUS/MPI/PPI/FWL
communication connection between laptop and SIMATIC.

22
Introduction:
• CP5512 EXPRESS also can be used on PCI-E slot of desktop computer after the PCI-E to
ExpressCard converter, the function is same as Siemens CP5611,CP5621.

• CP5512 EXPRESS support hot plug and plug and play. Perfect isolation circuit and interface
protective circuit make you at ease to use it.

23
Communication service:

• PROFIBUS-DP master station class 1 and 2


• PROFIBUS-DP slave and SOFTNET-DP slave
• MPI/PPI/FWL communication
• S7 communication with SOFTNET-S7
• S5-compatible communication (SEND/RECEIVE based on the FDL interface) with SOFTNET-D or
SOFTNET-S7

24
CP5512 EXPRESS is suitable for the
following version or above version
softwares :
• STEP7 V5.2
SOFTNET-S7 V6.1
SOFTNET-DP, SOFTNET-DP slave from V6.1
STEP 7-Micro/WIN from V3.2 SP4
ProTool®, ProTool/Pro® V6.0 SP2
NCM PC from V5.2
SIMATIC PDM V5.2 SP1

25
Technical Specification:
• Transmission rate: 9.6Kbps~12Mbps,the corresponding largest communication distance accord
with PROFIBUS standard.
• Interface: Connect PROFIBUS/MPI/PPI, isolated 9 pin Sub-D connector.
• Isolated voltage:1000VDC
• Interface protection: Have anti-lightning and surging protection(Ipp=100A 10/700us,4KV) on the
RS485 interface.ITU-TK20/21,VDE 0433 standard. ±15KV ESD protection. Overcurrent protection
with restoration function:RS485 port can withstand up to 60V voltage caused by continuous
over-current.
• Standard working voltage:3.3 VDC
power:1.0W
working temperature:-20~+75℃
Size:adapter:length* width * height(mm):123×68×30,
• cable length: 25CM
weight:150g
26
Support hardware of CP5512 EXPRESS:
• It’s different from PC Adapter and PC Adapter USB, CP5512 EXPRESS supports much more
hardwares, such as Siemens S7-200/300/400PLC, PPI/MPI/PROFIBUS interface of touch panel,
EM277,ET200 and other hardwares with PROFIBUS/MPI/PPI/FWL interface.
• It need PROFIBUS cable or MPI cable(Siemens part nr 6ES7 901-0BF00-0AA0) when CP5512
EXPRESS communicates with fieldbus devices.

27
Signal definition of CP5512 EXPRESS Profibus
Interface(DB9F):

28
MPI Cable: Cable between S7-200/300 PLC
and Siemens touch panel

US$18.00-$32.00

Correspond to Siemens 6ES7 901-0BF00-0AA0 29


Description
• Communication cable between S7-200/300 PLC and Siemens touch
panel,5 meters, correspond to Siemens 6ES7 901-0BF00-0AA0.
• CP5611,CP5512 need this cable to connect to a PLC.

30
CP5611: Communication Card for Desktop
Computer.

US$209.00-$418.00

31
Correspond to Siemens 6 GK1 561-1AA00
Description
• CP5611 communications cards which is Anti-lightning and anti-surge, corresponding to the
Siemens 6 GK1 561-1AA00, photoelectric isolation, and applied to desktop computer's PCI slots,
to achieve the PROFIBUS DP / MPI / PPI communications between PC or PG and the SIMATIC
network, communication rate is 9.6 Kbps ~ 12Mbps.
• Not including MPI extension cable for card communication, if you also need this, please also order
it:
• Overview:
CP5611 communication card is optoelectronic isolated design for industrial applications. There is
anti-lightning & anti-surging protection circuit and over-current protection on the RS485 port. The
adoption of industrial chip applies to a wide temperature range. CP5611 card is used to achieve
the PROFIBUS DP / MPI / PPI communication between PC or PG and the SIMATIC network.

32
Description
• Communication services:
PROFIBUS-DP master grade 1 and 2
PROFIBUS-DP slave and SOFTNET-DP slave
MPI/PPI communication
PG/OP communication
S7 communication with SOFTNET-S7
• S5-compatible communication (SEND/RECEIVE based on the FDL interface)
with SOFTNET-DP or SOFTNET-S7
• CP5611 applies to the following software:
STEP7 V.52 and above
SOFTNET-S7
SOFTNET-DP
SOFTNET-DP slave
COM PROFIVUS V3.3 and above
STEP 7-Micro/WIN V3.1 and above
ProTool, ProToo/Pro
NCMPC
33
Technical specifications:
• Transmission rate:9.6Kbps~12Mbps, corresponding maximum communication distance conforms
to PROFIBUS standard
Interface: PROFIBUS/MPI/PPI, isolated 9-pin Sub-D socket
Isolation Voltage: 1000VDC
RS485 port with anti-lightning and anti-surging protector, repeatability surge capacity: Ipp = 100A
(10/700us, 4KV)
Standard: ITU-TK20/21, VDE 0433. ± 15KV ESD (ESD) protection
Over-current protection: RS485 interface can withstand up to 60V voltage caused by the
sustained over-current
PG/PC connection: PCI2.1 standard slot
Standard voltage: +5 VDC
Power: 2.0W
Operating temperature: 0 ~ + 70 'C
Size (width x high) (mm): 102 x 130
Weight: 100g

34
OP Programming Cable: Siemens OP
Programming Cable

US$18.00-$36.00

35
Siemens OP programming cable,3 meters, correspond to Siemens 6XV1 440-2KH32
OMRON CQM1 PLC CABLE CIFOS

36
37
38
One-to-one Link Connections

39

Potrebbero piacerti anche