Sei sulla pagina 1di 64

PC200-8

Monitor Operation

PC200-8
Outline of Screens and Switches (1)

Large type 7-inch


liquid crystal display

Function SW

Work mode and wiper SW

Air-conditioner SW

PC200-8 Page 2 / 65
Outline of Screens and Switches (2)

①: Air-conditioner display
②: Wiper display
① ②③④ ⑤ ⑥ ⑦ ⑧ ③: Swing lock display
④: Preheating display
⑤: Clock display (service meter
⑫ ⑪ ⑩ ⑨ selectable alternately)
⑥: Auto-Decal display
⑦: Work mode display
⑧: Travel display
⑨: ECO display
⑩: Fuel capacity
⑪: Hydraulic oil temperature
⑬ ⑭ ⑮ ⑫: Engine water temperature
⑬: Auto-Decel SW
⑭: Work mode select SW
⑯ ⑰ ⑱
⑮: Travel mode select SW
⑯: Buzzer cancel SW
⑰: Wiper SW
⑱: Washer SW

PC200-8 Page 3 / 65
Function Switches

8-type multi-monitor
adopts [6 functional
switches].

PC200-8 Page 4 / 65
Start-up Screen and End Screen

Power-ON Komatsu logo screen Power-OFF Screen display remains 5 sec.


(for 2 sec)

Start-up inspection screen


(2 sec)

Work mode and travel display


(2 sec)

Normal screen

PC200-8 Page 5 / 65
Service Meter Reading with Key-OFF


Keep Buzzer cancel SW and Auto-decelerator
SW pressed

PC200-8 Page 6 / 65
Work Mode Selection (1)

If no operation is made
for 5 sec and over, press
F5 (return) to return to the
normal screen
Press Work Mode
Select SW
Each pressing of selects a work mode from P  E  L  B  P
1)

2) Work mode can be selected also by using ( ) and ( )

Press to confirm the selected mode

Displays 2 sec Displays 2 sec

PC200-8 Page 7 / 65
Work Mode Selection (2)

If no operation is made
for 5 sec and over, press
F5 (return) to return to the
normal screen
Press Work Mode
Select SW
Press to select B
1)

2) Press ( ) to select B

Press ( ) to confirm the selected mode

If breaker mode is
selected, the screen
to the left always
appears.

PC200-8 Page 8 / 65
Travel Speed Selection

Displays 2 sec Displays 2 sec

Each pressing of Travel


Speed Select SW
selects a speed from
Lo  Mi  Hi

PC200-8 Page 9 / 65
Auto-Decelerator Selection
Pressing Auto-Decel Select Switch
selects auto-deceleration.

When auto-decel is selected, an icon appears


to the upper left-hand corner of the screen.

PC200-8 Page 10 / 65
Wiper Switch/Washer Switch

An icon appears to the upper left-hand corner of the screen while the
wiper is in operation.
The figure below indicates "INT" wiping operation

Each pressing of
Wiper Switch selects
INT  ON  OFF .

Washer operates
while Washer Switch
is pressed.

PC200-8 Page 11 / 65
Air-Conditioner Display Screen
If no operation is made for 5 sec and
over, press F5 (return) or F6 (decide)
to return to the normal screen

:Automatic air-conditioning switch

:Air-conditioner switch
Air outlet port
  
LCD Air blow mode Remarks
:OFF switch
Front blow out
Selection disabled during
automatic operation

Front and rear blow out    :Air flow rate setting (for 6-stage adjustment)
Front and rear below blow out
:Temperature setting
Blow out downward

Blow out downward


:Inside/outside air selection
Selection disabled during
Defroster blow out automatic operation

Selection disabled during


Defroster blow out automatic operation
:Air blow selection

PC200-8 Page 12 / 65
ECO Display/Energy-Saving Guidance Display
ECO display
 This display indicates the work load
state.
 If the indicator changes to orange, it
does not mean machine failure

Energy-saving guidance display

 If the lever remains in neutral


position successively for 5 minutes
and over without error/caution
indication, the display changes to
this screen, prompting operator to
stop engine.
 A lever operation or pressing F5
restores the original screen.

PC200-8 Page 13 / 65
Camera Screen
Camera mark appears to F3 key
only if camera setting is present

Press F3 switch
( )

Press F5
switch
( ) ① ② ③ ④
Camera 1 and 2 screens appear

: Screen display for the first camera set up


: Screen display for the second camera set up
: Screen display for the 3rd camera set up
: Camera 1 and 2 screens appear

PC200-8 Page 14 / 65
Camera Screen (Warning, Error Generation
and Other Operations)
If error & caution are generated Error generation time

If an error is
generated and the
lever is at neutral
position for 10 sec
and over, the
display returns to
normal screen

If air-condition operation, travel speed selection or work mode change is made on the camera screen,
the display shifts to respective screen.

After the operation is completed, the After the operation is completed, the
After the operation is completed, the display returns to the standard screen. display returns to the standard screen.
display returns to the camera screen.

PC200-8 Page 15 / 65
Service Meter/Clock Selection

When displaying clock


When displaying service meter

Each pressing of F4
function switch selects the
clock and service meter
display alternately

PC200-8 Page 16 / 65
Maintenance Screen

Maintenance item
 Engine oil replacement
 Engine oil filter replacement
 Fuel main filter replacement
 Fuel pre-filter replacement
 Hydraulic oil filter replacement
 Hydraulic oil tank breather
replacement
 Damper case oil check and
replenishment
 Final case oil replacement
 Hydraulic oil replacement

Select an item
      and press F6
switch

Pressing F5 ( ) Maintenance time reset screen


function switch selects this
screen

To reset press
F6 ( )
Pressing F5 or F6 switch or
making no operation for 30 sec
restores the normal screen

PC200-8 Page 17 / 65
User Menu Screen

Pressing F6 ( )
function switch selects this
screen

Press F5 switch to Select and press F6


return to normal screen switch to shift to a
selected screen.
User menu item

 Breaker/Attachment setting (displayed only when attachment setting is made)


 Message display (displayed only when KOMTRAX is present)
 Screen adjustment
 Clock adjustment
 Language setting
 Economy mode adjustment

PC200-8 Page 18 / 65
Breaker/Attachment Setting

Select the breaker/


attachment setting item
and press F6 switch

Work mode select screen

B, ATT appear on the


work mode select screen
on the machine installed
with the breaker and
attachment

PC200-8 Page 19 / 65
Breaker Mode Flow Rate Setting Change
Select breaker and
press F6 switch Breaker flow rate
setting change

Select the breaker flow


rate item with F3 and
confirm with F6

Breaker flow rate


setting screen

Breaker setting
Select the
breaker with
Default setting is as follows:
Breaker 180 l/min F3 and F4
Breaker 100 l/min and confirm
with F6

Work mode select screen

Select the flow


rate with F3
and F4 and
confirm with F6

Press F5 to return to
the preceding screen

PC200-8 Page 20 / 65
Attachment Flow Rate Setting Change
Select attachment and
press F6 switch Attachment flow rate
setting change

Select the attachment


flow rate item with F3
and confirm with F6

Attachment flow rate


setting screen

Default setting is as follows: (A) Select the


Attachment 430 l/min attachment with
Attachment 430 l/min Attachment setting
(B) F3 and F4 and
confirm with F6

Select the flow


rate with F3
and F4 and
confirm with F6

PC200-8 Page 21 / 65
Screen Adjustment
Nighttime screen adjustment

Select the screen


adjust item and
press F6 switch

Daytime screen adjustment

Light switch F2: Resets all adjusted values to the


default values
F3: Shifts the indicator to the left
For night F4: Shifts the indicator to the right
F5: Returns to the user menu screen
F6: Confirms the change and shifts on
For daytime to the following item
Shifts to luminance adjustment

Contrast adjustment

Brightness adjustment

and back to luminance adjustment

PC200-8 Page 22 / 65
Clock Adjustment
Select the clock
adjust item and
press F6 switch

③ ④
F3: Advances time by one (1) hour F4: Sets the time back by one (1) hour
(For minute adjustment, this advances (For minute adjustment, this sets the
time by one (1) minute) time back by one (1) minute)

:F3: Shifts to the item on the left


:F4: Shifts to the item on the right
:F5: Cancels the change and
returns to the user menu screen
① ② ③ ④ :F6: Confirms the change
① ② ③ ④
PC200-8 Page 23 / 65
Language Setting

F3: Moves down to an


item directly below
F4: Moves up to an item
directly above
F5: Cancels the change
and returns to the
user menu screen
F6: Confirms the change
and shifts on to the
user menu screen
Select the language
setting item and
press F6 switch

Ten (10) languages indicated in the diagram below can be set up

PC200-8 Page 24 / 65
Economy Mode Adjustment
Eco-mode (E) is available for the
fuel-economy-minded customers

Select the economy


mode adjust item
and press F6 switch

F3: Moves down to an item directly below


F4: Moves up to an item directly above
F5: Cancels the change and returns to the
user menu screen
F6: Confirms the change and shifts on to
the user menu screen

PC200-8 Page 25 / 65
Cautions
Symbol Display item Conditions for generation Display method to operator アイコン メンテナンス項目 アイコン
Symbol indication and
Engine water
temperature overheating
102C or higher intermittent buzzer
sounding
Automatic preheating indication
エンジンオイル交換

Engine water temperature 30C or lower Symbol indication


low エンジンオイルフィルタ交換
Symbol indication and
Hydraulic oil temperature drop
Hydraulic oil temperature
102C or higher intermittent buzzer 燃料メインフィルタ交換
overheating
sounding

Hydraulic oil temperature 20C or lower Symbol indication Hydraulic oil temperature rise
燃料プレフィルタ交換
low

Fuel low Fuel gauge 0 indication Symbol indication 作動油フィルタ交換


Coolant capacity drop
When the sensor Symbol indication and
Radiator coolant level
contact is OPEN intermittent buzzer 作動油タンクブリーザ交換
abnormally low
sounding

Charge voltage
Monitor input during
engine operation falls
Charging voltage drop
abnormally low short of specified value Symbol indication ダンパケースオイル点検補充
(7.8V)
During engine
Air cleaner clogging operation and the
sensor contact OPEN
Symbol indication Water in fuel
ファイナルケースオイル交換

During engine operation Symbol indication and


Engine oil pressure
abnormally low
and the engine oil intermittent buzzer マシナリケースオイル交換
pressure is 0.5k or under

Engine stopping and


sounding
Overheat
Engine oil capacity the sensor contact Symbol indication
abnormally low 作動油交換
OPEN

Water in fuel
Sensor voltage outside Symbol indication Engine oil capacity drop
specified range

Remaining time to the


Maintenance preliminary maintenance is less 30 sec indication after
notice than 30 hours start-up Fuel level low
Remaining time to the
maintenance is less 30 sec indication after
Maintenance warning
than 0 hours start-up

PC200-8 Page 26 / 65
Service Menu Screen

Pressing
+1,2,3 selects
screens

Service menu item

01 Monitoring
02 Failure history
Select an item and
03 Maintenance history press F6 switch to shift
04 Maintenance mode change to a selected screen.
05 Telephone number setting
06 Default setting
07 Adjustment
08 Arm crane setting
09 Operation on reduced cylinders
10 No-injection cranking
11 Fuel consumption display
12 KOMTRAX setting indication (only when KOMTRAX setting provided)
13 KOMTRAX message indication (only when KOMTRAX setting provided)

PC200-8 Page 27 / 65
Monitoring

Select the Select the item and press


monitoring item F6 switch
and press F6 Up to 6 items can be
switch selected.

Enter 99999 and press
F6 to select the
monitoring screen.
(The monitoring screen
appears also by pressing
F6 a bit longer or by
double-clicking F6)

Select an item
and press F6
switch to shift to a
Pressing the work mode select, travel select or selected screen.
auto-decel switch during monitoring shifts the
display to this screen.

Pressing Hold
(F4) fixes the
numeric value
at the time of
the pressing.

PC200-8 Page 28 / 65
Failure History
Service Menu Screen Failure History Select Screen
Select the failure
history item and
press F6 switch
Select the item
and press F6
switch

Failure history Failure history


of mechanical of electrical Failure history
system system of air-conditioner

Deletion of
failure history
of the
"E" indicates mechanical Pressing F2
that the system switch erases
remains in error system is not the air-
condition. available. conditioner error.

PC200-8 Page 29 / 65
Failure History Reset
Memorize necessary failure histories before erasing.
Pressing
+1,2,3 selects
screen

Press F2 switch ( CLEAR) Select the item


and press F6
switch
Screen to erase all electrical abnormality record information Screen to erase individual electrical abnormality record information

Press F6 to Press F6 to
erase all erase
selected
item

PC200-8 Page 30 / 65
Maintenance History

Select the maintenance


item and press F6 switch

PC200-8 Page 31 / 65
Maintenance Mode Change
Maintenance Mode Change Screen
Service Menu Screen Select the Maintenance Mode Change
maintena 00 Maintenance mode using/not using
nce mode 01 Engine oil replacement intervals
change 02 Engine oil filter replacement intervals
item and 03 Fuel main filter replacement
press F6 41 Fuel pre-filter replacement
switch 04 Hydraulic oil filter replacement intervals
05 Hydraulic oil tank breather replacement intervals
07 Damper case oil inspection and replenishment intervals
98 Final case oil replacement intervals
09 Machinery case oil replacement intervals
10 Hydraulic oil replacement intervals
99 Initialize all (not to be indicated on the menu)

Select the item and


press F6 switch

00: Maintenance Mode On/Off screen 01: Engine Oil Change Interval screen 1 99: Screen to clear all to the initial set values

PC200-8 Page 32 / 65
Telephone Number Setting
Service Menu Screen Phone Number Entry screen

Select the telephone


number setting item
and press F6 switch

Make entry using the number keys


(0 to 9) and press F6 key to confirm
or press CLEAR to erase the
entered number.

Pressing F5 SW returns to
the preceding screen.

Telephone number will


appear to the bottom if
an error occurs

PC200-8 Page 33 / 65
Default Setting
Service Menu Screen Default Screen

Select the
default setting
item and press
F6 switch

Default Setting

01 Work mode on power-ON


02 Unit selection
03 Attachment yes/no
04 Attachment/Maintenance password setting
05 Camera setting
06 ECO display setting
07 Breaker automatic judgment setting
10 Initialize all (not to be indicated on the menu)

PC200-8 Page 34 / 65
Work Mode Display on Power-ON

Select the
work mode
item on
power-ON and
press F6
switch

Select a mode item and press F6 to change


the screen from the start-up to a selected item.

Start-up screen Pressing F6 after entering "10" from the number keys on the
default setting screen will set the default upon power-ON to the
work mode the system was in when it was turned-OFF last time.
Work mode and travel display (2 sec)
If the breaker
mode was
selected, the
screen to the
Normal screen left appears
at start-up for
each power-
ON.

PC200-8 Page 35 / 65
Unit Selection

Select the unit


selection item and
press F6 switch

Pressing F6 after entering "10" (all to default) using the number keys in the default
setting screen sets to the SI unit system mode.

PC200-8 Page 36 / 65
Attachment-yes/no

Select the Attachment-


yes/no item and press F6

Pressing F6 after
selecting the
"Attachment-no"
deletes ATT from the
work mode select
screen.

Pressing F6 after entering "10" (all to default) using the number


keys in the default setting screen sets to the "Attachment-no"
mode.

PC200-8 Page 37 / 65
Attachment/Maintenance Password Setting

Select the item


and press F6
switch

If selected to "Use" password, the


password screen (diagram below) appears.

Pressing F6 after entering "10" (all to default) using the


number keys in the default setting screen sets to the
"Attachment password not using" mode.

PC200-8 Page 38 / 65
Camera Setting

Select the
camera setting
item and press
F6 switch

Set the rear mounted


Two (2) screens will camera in reverse image
appear only when set for
using Camera 1 and 2

Pressing F6 after entering "10" (all to default) using the


number keys in the default setting screen sets to the
"three (3) cameras not in use" mode

PC200-8 Page 39 / 65
ECO Display Setting

Select the ECO


setting item and
press F6 switch

 Selecting OFF for the ECO display turns the  Selecting OFF for the ECO guidance display turns the
screen to no display screen to no display

ECO display

PC200-8 Page 40 / 65
Breaker Automatic Judgment Setting

Select the item


and press F6
switch

When to "Use" is selected

If the breaker is hit in a mode other than B, the


pump controller automatically judges the breaker
and prompts operator to change the mode to
Mode B by displaying the screen to the left.

This judgment by the pump controller depends on


Working Mode is not Breaker Mode. the waveform of the pump hydraulic oil pressure.
Set Breaker Mode during using Breaker. Therefore the pump controller may make the
same judgment by error with other waveform
similar to that of the breaker pump oil pressure for
which care should be taken.

PC200-8 Page 41 / 65
Set All to Default
Default Screen Screen to clear all to the initial set values
Enter "1" and "0"
using the number
keys and press
F6

Default Setting Default

01 Work mode on Power-ON Work mode at preceding Power-OFF time


02 Unit selection ISO unit
03 Attachment-yes/no Attachment-no
04 Attachment/Maintenance Password Setting Not using
05 Camera setting Three (3) cameras not using
06 ECO display setting Display
07 Breaker automatic judgment setting Not using
10 Set all to default (not to be indicated on the menu)

PC200-8 Page 42 / 65
Adjustment

Select the adjustment


item and press F6 switch

 Adjustment item code No.  Parameter values


021:Pump Absorption Torque (F) Pump absorption torque (F) or (R)
022:Pump Absorption Torque (R) Parameter value Torque
020:Low Speed 008 +4 kg・m
044:Attachment Flow Adjustment 007 +3 kg・m
 
006 +2 kg・m
005 +1 kg・m
004 0 kg・m
003 -1 kg・m
002 -2 kg・m
001 -3 kg・m
000 -4 kg・m

PC200-8 Page 43 / 65
Adjustment (Pump Absorption Torque (R))
Select "Pump
Absorption Torque
(R)" and press
"F6"

 Adjustment item code No.  Parameter values


021:Pump Absorption Torque (F) Pump absorption torque (F) or (R)
022:Pump Absorption Torque (R) Parameter value Torque
020:Low Speed 008 +4 kg・m
044:Attachment Flow Adjustment 007 +3 kg・m
 
006 +2 kg・m
005 +1 kg・m
004 0 kg・m
003 -1 kg・m
002 -2 kg・m
001 -3 kg・m
000 -4 kg・m

PC200-8 Page 44 / 65
Adjustment (Low Speed)

Select "Low Speed"


and press "F6".

 Adjustment item code No.  Parameter values


021:Pump Absorption Torque (F) Low Speed
022:Pump Absorption Torque (R)
Parameter value Speed
020:Low Speed
044:Attachment Flow Adjustment 003 3.4km/h ① ②
002 3.2 km/h
000 3.0 km/h
001 2.8 km/h

PC200-8 Page 45 / 65
Adjustment (Attachment Flow Adjustment)

Select "Attachment
Flow Adjustment" and
press "F6"

 Adjustment item code No. ②Parameter values


021:Pump Absorption Torque (F) Attachment Flow Adjustment
022:Pump Absorption Torque (R) Parameter value Flow rate to ATT
020:Low Speed (Compound operation
044:Attachment Flow Adjustment during boom RAISE)
① ②
003 38%
002 100%
001 70%
000 50%

PC200-8 Page 46 / 65
Operation on Reduced Cylinders
Cylinder Cut-Out Screen

Select the item and


press F6 switch

Use F1 and F2 to select a cylinder cut-out


number and press "F6" SW. Then the background color
of the selected cylinder number turns white from yellow
to enable the cylinder cut-out mode.
1 1
To disable the cylinder cut-out mode, press "F6" SW; the
background color of the selected cylinder number turns
light-blue from red to stop cylinder cut-out operation.
1 1

PC200-8 Page 47 / 65
Cylinder Cut-Out Mode Operation (Hold)

Press
"F4"
(Hold).

1 1

PC200-8 Page 48 / 65
No-injection Cranking
Select the item
and press F6 Condition 1
switch The following conditions remain satisfied
for 3 sec
(1) CAN communication normal
(2) Engine revolution: 0 rpm
(3) Operation on reduced cylinders normal
If the conditions are not met,
F5 ( ) the screen returns to no-injection cranking
display.

No-injection Cranking

Set to no-injection
cranking?
Returns
automatically Turning the start-up switch
to the service ON on the "No-injection
menu screen cranking enabled" screen set
the machine to no-injection
F6 ( ) cranking mode.

No-injection Cranking No-injection Cranking No-injection Cranking


F6 ( )
No-injection
Ending no-injection 無噴射クランキング可能
cranking enabled Engine running
cranking
After ending no-
injection mode

PC200-8 Page 49 / 65
Fuel Consumption Display
Service Menu Screen

Select the
item and
press F6
switch

F1 (START) switch: split fuel consumption measuring start


F1 (STOP) switch: split fuel consumption measuring end
F2 (CLEAR) switch: clear display

PC200-8 Page 50 / 65
Password Setting (1)
Normal screen No transition before the Password screen
lapse of 10 minutes after Initial password
Power-ON change
Password entry
+729729
automatically
transfers to the
lock menu screen
upon entering
"000000" from the
number keys.

Change Lock Setting screen Engine Start Lock screen

Select "Change
Lock Setting"
and press "F6".

PC200-8 Page 51 / 65
Password Setting (2)
Engine Start Lock screen New Password screen
Select "Change
Password" and Entering a new
press "F6". password from the
numeric keypad
appears "******".
Pressing "F6" SW
changes to the "New
Password screen".

"Password? screen"

Entering a new password from the


numeric keypad appears "******".
Pressing "F6" SW changes to the
"Engine Start Lock screen" after three
seconds lapsed.

PC200-8 Page 52 / 65
Password Entry Screen on Power-ON

Power-ON

Password entry screen

The next screen


does not appear
unless a legal
password is entered

PC200-8 Page 53 / 65
Attachment/Maintenance Password Setting
Password Entry screen
Normal screen No transition before the lapse
of 10 minutes after Power-ON
unless the setting is for
+Attachment/Maintenance
Password.

+555

"Password? screen"

Entering the second new password


from the numeric keypad appears
"******". Pressing "F6" SW changes
to the normal screen after about
three seconds lapsed

PC200-8 Page 54 / 65
List of Cautions and Icons

PC200-8 Page 55 / 65
Monitoring Code Table-1

PC200-8 Page 56 / 65
Monitoring Code Table-2

PC200-8 Page 57 / 65
Monitoring Code Table-3

PC200-8 Page 58 / 65
Monitoring Code Table-4

PC200-8 Page 59 / 65
Monitoring Code Table-5

PC200-8 Page 60 / 65
User Code Table

PC200-8 Page 61 / 65
Error Code Table-1

PC200-8 Page 62 / 65
Error Code Table-2

PC200-8 Page 63 / 65
Error Code Table-3

PC200-8 Page 64 / 65

Potrebbero piacerti anche