Sei sulla pagina 1di 4

CAMERON WELLHEAD

CCU CONTROL PANEL


WELLHEAD CAMERON CCU CONTROL PANEL

Actuator

Pilot Isolation Valve


SCSV Control Line Pressure
Drain Valve
Pumping Unit

SCSSSV Flushing Isolation Valve


High Pilot
Flushing Connection
Low Pilot

Gate Valve Isolation Valve


SCSSSV Control Line pressure

Hydraulic Tank
PROCEDURE
• To trip and shut down SCSV & SCSSSV, use
drain valve.
• To open both SCSV & SCSSSV, open both SCSV
& Gate Valve isolation valves and then pump
from pump unit.
• To open only one of SCSV or SCSSSV, isolate
one of the SCSV or SCSSSV Isolation Valve.
• To place CCU unit on auto, open pilot isolation
valve
PLACE CCU ON AUTO
• Shut well at WV & FL valve
• Ensure pilot isolation valve is on manual
(closed position)
• Gradually open WV and introduce pressure LT
high and GT low pilot set points (500psi)
• Open pilot isolation valve to place well on
auto.
• Open wv & FLV such that low and high set
points are not exceeded.

Potrebbero piacerti anche